CHECKUP PROFESSIONAL Protocol to service on 12.02.2019 S-40114028 / Call 2862 Technician: Leis Tritz Customer: Customer XYZ Machine type: ZSE 50 MAXXtorque - 44D Serial no.: 03608 OVERALL EVALUATION The extruder has at least one critical point, which has to be fixed immediately.
17
Embed
CHECKUP PROFESSIONAL - Leistritz · 2020. 3. 23. · CHECKUP PROFESSIONAL Protocol to service on 12.02.2019 S-40114028 / Call 2862 Technician: Leis Tritz Customer: Customer XYZ Machine
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
CHECKUP PROFESSIONAL
Protocol to service on 12.02.2019
S-40114028 / Call 2862
Technician: Leis Tritz
Customer: Customer XYZ
Machine type: ZSE 50 MAXXtorque - 44D
Serial no.: 03608
OVERALL EVALUATION
The extruder has at least one critical point, which has to be fixed
immediately.
page
1. OVERVIEW 3
2. BARREL MEASUREMENT 4
3. SCREW MEASUREMENT 6
4. DRIVE TRAIN 8
5. TEMPERATURE CONTROL 11
6. VACUUM PUMP 13
7. EXTRUDER (GENERAL) 13
8. SAFETY SHUTDOWNS 14
9. DOSING SYSTEM 15
10. SUMMARY 16
11. ATTACHMENT 17
11.1. CERTIFICATE
1. OVERVIEW
The vacuum pump works properly. Some points of the CheckUp are not
accepted and requires an action.
Some barrels already passed the accepted wear limit
and has to be exchanged. All points in scope of the CheckUp are
accepted.
Some screw elements already passed the accepted wear
limit and have to be exchanged.
All points in scope of the
CheckUp are accepted.
All points in scope of the CheckUp
are accepted.
BARREL MEASUREMENT
SCREW MEASUREMENT
CHECK OF THE DRIVE TRAIN
SAFETY SHUTDOWNS
VACUUM PUMP TEMPERATURE CONTROL
DOSING SYSTEM
Next CheckUp 02.2020
page 3 of 17
page 4 of 17
2. BARREL MEASUREMENT
Wear on the following areas detected no signs of wear
main melting zone
after the sidefeeder
discharge section
immediately 6 months 12 months
Some barrels already passed the accepted wear limit and has to be
exchanged.
The barrels 02 & 03 in the main melting zone have passed the wear limit by far and constitue a
critical condition of the maschine. The barrels 05 & 08 have also reached the accepted wear limit. All
mentioned barrels have to be exchanged immediately.
Comment:
We recommend to exchange the
yellow marked barrels within the
following period
ntro
ntrollkntrollkntrollk
ntrontr
ntrollk
ntrollk
Customer XYZ Type: ZSE 50 MAXXtorque - 44D Date: 12.02.2019 Serial no.: 03608 Version 01