8/22/2019 Checklist Building Appraisal
1/13
BUILDING APPRAISAL
PRESENTED BY:
Aditi Dekate 111110019
Ayushi Hajare 111110029
Prasenjit Shukla 111110030
Asmita Patil 111110039
8/22/2019 Checklist Building Appraisal
2/13
QUESTION STANDARDS What exist @
site.
Inference/
Recommendation
I. DrainageStudy of
topography of site
Slope
contours
Appropriate slope is1:60
How are the
contours on site?
Climatic data of
the site
Precipitation(
rainfall), areas
where water
logging and
occasional flooding
occurs
study of rainfall and
any king of flooding( if
any) gives us an idea
about minimum
elevation of building
from ground
What methods
have been used
for surface run
off?
Natural slope of
ground?
Open drains?
Closed drains?
8/22/2019 Checklist Building Appraisal
3/13
QUESTION STANDARDS What exist @
site.
Inference/
Recommendation
Placement ofunderground
drain pipes on
site
Size of drainage
pipes
Placement of
open drain
Size of drains
Is their any kindof backflow in
open drains?
In case of backflow,study of ways used
on site to prevent
this.
8/22/2019 Checklist Building Appraisal
4/13
QUESTION STANDARDS What exist @
site.
Inference/
Recommendation
Is their any placewhere water
logs?
How has this beenprevented?
Where is theplacement of
gutter pipes?
What is the
slope of pipes?
Where are the
man holes
placed? What is
the spacing
between them?
Ideally 2 manholes
are at a minimum
distance of 400 m
8/22/2019 Checklist Building Appraisal
5/13
QUESTION STANDARDS What exist @
site.
Inference/
Recommendation
WATER SUPPLY
1. Any nearby
watercourses.
2. Capacity of
sump well tank
and storage
tank.
3. Total no. of tanks
and their position.
4. Pressure of
pump.
5.Height at whichgravity tank is
placed.
8/22/2019 Checklist Building Appraisal
6/13
QUESTION STANDARDS What exist @
site.
Inference/
Recommendation
RAINWATERHARVESTING
SYSTEM
1. Storage capacity
of tank.
2. Underground/
overhead tank.
3. Is filtration
system present.
FIRE PROTECTION
SYSTEM
1. Capacity of
tank.
2. Presence of
sprinkers or
pumps.
8/22/2019 Checklist Building Appraisal
7/13
QUESTION STANDARDS What exist @
site.
Inference/
Recommendation
SEWAGE1. Presence of
open or closed
drains.
2. Depth at which
pipelines are
placed.3. How is waste
disposed off.
4. Placement and
height of vent
pipes.
5. Dimensions
and placement of
gully traps.
8/22/2019 Checklist Building Appraisal
8/13
QUESTION STANDARDS What exist @
site.
Inference/
Recommendation
AIR CONDITIONINGI. Kind of system
Unitary
Centralized
Packed terminal
Capacity ofcooling systems
according to
rooms
, 1 , 1 , 2 , 2 ,and of larger
capacity
Kind of units
used in room
Split , window ac,
cube ac, or any
other
Help to determine the
space occupied by
units
8/22/2019 Checklist Building Appraisal
9/13
QUESTION STANDARDS What exist @
site.
Inference/
Recommendation
Where is theplacement of
compressor
units?
Is their any kind
of leakage?
Does the placementeffect the faade in
any way?
Proper placement ofunits
II. DUCTS What is the duct
network system?
Placement of ducts.Are all the ducts
concealed or
visible?
What materialhas been used
for ducts
8/22/2019 Checklist Building Appraisal
10/13
QUESTION STANDARDS What exist @
site.
Inference/
Recommendation
What are thesizes of the
ducts?
III. Cooling fans Placement of
cooling units in
rooms
8/22/2019 Checklist Building Appraisal
11/13
QUESTION STANDARDS What exist @
site.
Inference/
Recommendation
ELEVATORS
UsageNo of people using
Elevators
Load on elevator
Small 400kg
(passenger withhand baggage)
Medium 650 kg (+
prams and wheel
chairs)
Large 1000 kg (+
furniture, coffins
Helps in determining
the no of elevatorsrequired and size of
elevators
Hoisting
machinery
Placement of
hoisting machinery
And its dimensions
It placed on the
roof above the
elevator
8/22/2019 Checklist Building Appraisal
12/13
QUESTION STANDARDS What exist @
site.
Inference/
Recommendation
Elevator shaft
1. What is theheight of shaft
at the top floor?
2. What are the
dimensions ofthe shaft?
3. What is the
depth of
elevator pit?
It usually dependson the distance
between top floor
and the roof.
Provisions for
services andcounter weights
have to be
provided.
These are usually
1500 mm to 3500
mm deep
8/22/2019 Checklist Building Appraisal
13/13
QUESTION STANDARDS What exist @
site.
Inference/
Recommendation
Dimensions of
lifts
The dimension for
different loads aredifferent
minimum criterion
for wheel chair
bound person is
o 2000 mm width
of elevatoro 1300 depth of
elevator
o 900 minimum
opening
What is the
positioning of
control button?