R = Packing in reel CLASSIFICATION CONSTRUCTION CHAROONG THAI WIRE & CABLE PUBLIC COMPANY LIMITED APPLICATION REFFERENCE Product code No of core Conductor Number & diameter of wire (No./mm.) Diameter of conductor (mm.) Thickness of insulation (mm.) Thickness of bedding sheath (mm.) Thickness of overall sheath (mm.) Thickness of protective sheath (mm.) Overall diameter (approx) (mm.) Cable wight (approx) (kg/mm.) Maximun conductor resistance at 20 C ( /km.) Standard length (m/R) Size (mm ) 2 CTW-CVVN DSTA 750 V CABLE TYPE : CTW-CVVN-DSTA 750 V C72021501 C72024501 C72021502 C72024502 C72024004 C72024606 C72024010 C72024016 C72024025 1.5 1.5 2.5 2.5 4 6 10 16 25 2 1/1.38 7/0.50 1/1.78 7/0.67 7/0.85 7/1.04 7/1.35 7/1.70 7/2.14 1.38 1.50 1.78 2.01 2.55 3.12 4.05 5.10 6.42 0.8 0.8 0.8 0.8 0.9 0.9 1.1 1.1 1.3 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 1.0 1.3 1.3 1.4 1.4 1.4 1.5 1.5 1.6 1.7 1.2 1.2 1.2 1.2 1.2 1.2 1.3 1.3 1.4 16 16 17 17 19 20 23 25 29 350 350 400 400 510 600 800 1010 1400 12.1 12.1 7.41 7.41 4.61 3.08 1.83 1.15 0.727 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000 BS 6346: 1997, BS 6360 : 1991 and BS 6746 * AC Test Voltage 3 kV ** Minimum insulation resistance at 20 C 350 (M -km) Conductor Insulation Core Identification Bedding Armour Overall Sheath Termite Protective Protective Sheath : Plain annealed copper wire in according to BS 6360 : Polyvinyl choride (PVC) insulation Type TI1 in according to BS 6746 : BLACK with continuous print numbered on cores : BLACK Polyvinyl choride (PVC) insulation Type TI1 in according to BS 6746 : Double galvanize steel tape ( DSTA) armour thickness 0.2 mm. : BLACK Polyvinyl choride (PVC) insulation Type TI1 in according to BS 6746 : Nylon 12 thickness 0.5 mm. : Polyvinyl choride (PVC) insulation Type TI1 in according to BS 6746 : Maximum conductor temperature 70 C : Circuit voltage does not exceed 750 volts. : For controlling signals, lighting of signal lamps, controlling point machines and other singnalling equipment within the inter locked signal area : 750 V SIGNALLING AND POWER CABLE WITH NYLON TERMITE PROTECTIVE 64 Instrument & Control Cable
5
Embed
CHAROONG THAI WIRE & CABLE PUBLIC COMPANY LIMITED · ctw-cvvn dsta 750 v c72031501 c72034501 c72031502 c72034502 c72034504 c72034006 c72034010 c72041501 c72044501 c72041502 c72044502
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
R = Packing in reel
C L A S S I F I C AT I O N
CONSTRUCTION
CHAROONG THAI WIRE & CABLE PUBLIC COMPANY LIMITED
APPLICATION
REFFERENCE
Productcode
Noof
core
ConductorNumber &diameterof wire
(No./mm.)
Diameterof
conductor(mm.)
Thickness
of
insulation
(mm.)
Thicknessof
beddingsheath(mm.)
Thicknessof
overallsheath(mm.)
Thicknessof
protectivesheath(mm.)
Overalldiameter(approx)
(mm.)
Cablewight
(approx)
(kg/mm.)
Maximunconductorresistance
at 20 C( /km.)
Standardlength
(m/R)
Size
(mm )2
CTW-CVVN DSTA 750 V
CABLE TYPE : CTW-CVVN-DSTA 750 V
C72021501
C72024501
C72021502
C72024502
C72024004
C72024606
C72024010
C72024016
C72024025
1.5
1.5
2.5
2.5
4
6
10
16
25
2
1/1.38
7/0.50
1/1.78
7/0.67
7/0.85
7/1.04
7/1.35
7/1.70
7/2.14
1.38
1.50
1.78
2.01
2.55
3.12
4.05
5.10
6.42
0.8
0.8
0.8
0.8
0.9
0.9
1.1
1.1
1.3
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
1.0
1.3
1.3
1.4
1.4
1.4
1.5
1.5
1.6
1.7
1.2
1.2
1.2
1.2
1.2
1.2
1.3
1.3
1.4
16
16
17
17
19
20
23
25
29
350
350
400
400
510
600
800
1010
1400
12.1
12.1
7.41
7.41
4.61
3.08
1.83
1.15
0.727
1,000
1,000
1,000
1,000
1,000
1,000
1,000
1,000
1,000
BS 6346: 1997, BS 6360 : 1991 and BS 6746
* AC Test Voltage 3 kV
** Minimum insulation resistance at 20 C 350 (M -km)
Conductor
Insulation
Core Identification
Bedding
Armour
Overall Sheath
Termite Protective
Protective Sheath
: Plain annealed copper wire in according to BS 6360
: Polyvinyl choride (PVC) insulation Type TI1 in according to BS 6746
: BLACK with continuous print numbered on cores
: BLACK Polyvinyl choride (PVC) insulation Type TI1 in according to BS 6746