8/8/2019 Characters Tic of Charge Controller
1/58
Sky Resources Solar Technology Co., LTD ----projects Management Training document
8/8/2019 Characters Tic of Charge Controller
2/58
Clarification of the Solar Energy
Power GeneratingFollowing two type of the solar energy power generating
y Grid-off solar energy power generatingMain used in the area where is no electricity supply or the
telecommunication station which is faraway from the electricity net orthe wireless places.
Key componentssolar panelbatteryintelligent controllerinverterelectricity distribution and anti-lighting system. (electricity distribution is close to theactive load).
Advantagesoffer the independent electricity net which will not restricted by the
local public electricity net.Disadvantagesmuch waste of the energy resources or can controller the use of the
solar energy resources. the electricity use is high restricted by the weather condition, thelow efficiency of use and high investment, a little low system life span (especially say thebatters life span).
8/8/2019 Characters Tic of Charge Controller
3/58
y Grid-On PV System
Main use in the place where the city electricity distribution net. It isthe lead direction of New energy from home and all over the world.
Key components: solar panelgrid-on inverter electricity distribution andanti-lighting systemmuch simple ).
Advantageshigh efficient use of the systemlong life spanthe investmentcost is some lowerthe use of the electricity will not restricted by the system itself andthe weather condition influence.
Disadvantagesthe return of the electricity powered by solar will be restrictedby the local public electricity net.
8/8/2019 Characters Tic of Charge Controller
4/58
The Independent Grid-off Solar Energy Power Generating SystemDetailed Introduction
8/8/2019 Characters Tic of Charge Controller
5/58
Solar Panel/ModuleSolar Panel is a generating equipment which
can transfer the solar light energy to the DC
electricity energy. It is made as a single
panel when use according to the different
requirements on the power output and its
voltage. It also can be used as several solar
panel connected in series (which is to meet
the demands on voltage) and connected in
parallel (which is to meet the demands on
current). this way can make as the
panel/modules arrays to supply much higher
electricity demands. the solar panel/modules
has many advantages such as high powerefficiency on arealong life span, and high
reliabilityduring the use period, the loss of
the output power is less than 20%.
8/8/2019 Characters Tic of Charge Controller
6/58
The features ofVolt-Ampere for PV solar
panel
Generally speakingthe solarpanel electricity generating is
increased in percentage with
the intensity of the sunlight.
With the surface temperature
increased of the solar panel
slightly decreased.
The so-called general of the
solar panels that power is in
the sunlight intensity of 1000
W/M2, components, surface
temperature is 20, Imax *
Umax value.
8/8/2019 Characters Tic of Charge Controller
7/58
Photovoltaic module installation angle
Photovoltaic module installed inclination should be guaranteed to receive themaximum sunlight exposure, in normal circumstances components and thehorizontal direction for the local latitude 5to 10. That is, when thereduction in the summer, when the increase in the winter. If a fixed angle
brackets, the use of local latitude tilt angle. For example, the city of Shantou to23.42latitude.
8/8/2019 Characters Tic of Charge Controller
8/58
Battery discharge curves
y 10 hour rate (0.1 CA), 5 hour rate (0.17 CA), 3 hours rate (0.25 CA) dischargetermination voltage: 10.8 V /set; 1 hour rate (0.55 CA) discharge terminationvoltage: 10.5 V / set
y
Termination of battery discharge voltage minimum not more than 9.6 V / only to
ensure that the battery will not over-discharge.
8/8/2019 Characters Tic of Charge Controller
9/58
8/8/2019 Characters Tic of Charge Controller
10/58
Block diagram of the solar controller
8/8/2019 Characters Tic of Charge Controller
11/58
Small PV power Intelligent Controller
Characteristics
1. Solar protection reverse: solar + and - to the anti-polarity, after correct, it can continue to use.
2. Battery Open circuit protection: If the battery breaks, andbatteries can be rechargeable normally, the controllerwill be limited at both ends of load voltage, to ensurethat the load is not injury, if at night or solar battery not
be chartered, the controller due to its own access toelectricity, will not have any action;
3. Overcharge protection: protection of charge voltagehigher than the voltage, automatic shutdown ofrechargeable batteries. When the voltage then swap tomaintain voltage, battery enter Float state, when less
than restoring voltage Float closed, are sufficient toenter the state. Have sufficient voltage protection andrestoration of both temperature compensation voltageFloat;
4. When the battery voltage is lower than the protection ofvoltage, the controller automatically shut down outputin order to protect the battery from damage;
5. Over voltage protection: When high voltage, output shutdown automatically to protect against electrical damage.A charge, the release of over-voltage protection aredelayed action to prevent the disoperation.
6. With temperature compensation function
7. Variety of control options functions: general charge anddischarge mode, light is turned off mode, the opening ofthe shutdown mode
Small PV power
Intelligent Controller
5A10A
8/8/2019 Characters Tic of Charge Controller
12/58
Mi - r t v ltaic tr ll r
1.LCD display: LCD shows Users Display System importantinformation such as the battery voltage, the chargeCurrent and discharge Current, the operation mode and thesystem parameters, system status by the digital and English
2. Automatic / manual / night features: Programmable Load ControlWays to automatically or manually. Manual, manual loadOpen or closed. At this time, the evening function invalid. Whenchoosing night function, the controller closed in the daytime loaddetection evening,Automatically after a period of time delayed opening load, regulartime, it has been Dynamic load shut down. Regular time and delaytime based programmable Determined;
3. Protection features: over-charged, over-discharged, output overload,
over -Pressure, high temperature protection;
4. Float voltage with the temperature compensation function;5 fast charging functions: the battery voltage falls below a certain
value, rapid Start charging automatically, the controller willincrease battery power Pressure, when the battery voltage achievethe desired value, started fast charging When Countdownprocedures, regular time, with rapid charging state. Therefore, Fulluse of solar energy.
6. Automatic identification functions: the first power, in accordancewith electrical storage controller Pool automatic identificationterminal voltage is 12 V or 24 V system;
7. Mode: normal charge-discharge mode, light is turned off mode,- The opening of the shutdown mode.
Mid-Power Photovoltaic Controller
20A30A
8/8/2019 Characters Tic of Charge Controller
13/58
High-Power Photovoltaic Controller
High-Power Photovoltaic Controller
50A-100A
Standard 4U Cabinets
High-Power Photovoltaic Controller
150A-200A
Standard 6U Cabinets
8/8/2019 Characters Tic of Charge Controller
14/58
High-Power Photovoltaic Controller
Waterproof OutdoorMount
250A-400A
1200 Standard Cabinets
100A-200A
8/8/2019 Characters Tic of Charge Controller
15/58
The characteristics of the High-Power Photovoltaic Controller (1)
y DSP chip microcomputer control, the charge and discharge parameters,temperature compensation coefficient programmable arbitrary , can adaptto the special requirements of different occasions.
y LCD dot matrix modules that operate in both English and Chinese menu, users canswitch choice;
y Various LED indicator to display photovoltaic charge state and load-off state;
y 9 touch buttons;
y Control circuit totally isolated from the main circuit, high anti-jamming capability;
y
1-18 Road solar input control;y Real-time display battery voltage, load current, the total current
photovoltaic, Each PV current, battery temperature, the total number ofhours photovoltaic power generation, the cumulative load of electricity, andsome like several dozen parameters;
8/8/2019 Characters Tic of Charge Controller
16/58
The characteristics of the High-Power Photovoltaic Controller (2)
y the historical data and Statistics show: the number of charge cycles, the number of discharges,the number of overload, short-circuit number;Programmable voltage generator start-up and shutdown, secondary load-off voltage, wind generatorunloading and recovery voltage, street photosensitive parameters such as voltage switch;
y Users can set up a rechargeable battery discharge protection and the protection of the load-off state;
y With the Second ability to control, that is the main load and secondary load in different batteryvoltage electrical point of control;
y Various charge pressure of a "backlash" control functions, to prevent oscillation switch into the state;y Protection features: with a rechargeable battery, a discharge, output overload, short-circuit, surge,
solar or battery against a short circuit to the anti-battery at night and a series of anti-anti-sufficientwarning and protection;
y RS232/485 interfaces can be allocated to facilitate long-distance remote, remote control; PC controlsoftware can be measured real-time data, alarm information, change control parameters, read the
daily 30 days maximum battery voltage, battery voltage minimum daily PV and the total volume ofelectricity consumed by the daily load accumulated historical data;y Parameter settings and the ability to password-protect users may modify password;
8/8/2019 Characters Tic of Charge Controller
17/58
The characteristics of the High-Power Photovoltaic Controller (3)y Warning: over-voltage, under-voltage, overload, short-circuit protection, such as alarm;
y Multi-channel output report to the police or passive control contact: a rechargeable battery, a batterydischarge, Diesel boot control, load disconnect, controller fault; other user-selectable backup alarmcontact, such as f lood alarm;
y Work step by step-ladder pattern of limited mode, PWM mode, the opening of the off-model-turned-
down mode, the clock control mode, the light is turned off early-model, which is the model for thefirst two occasions common load, After four model load occasions against the lights, all the lengthand timing clock delay can be set up;
y Users can also set up parameters including: are charging pressure, Float voltage, voltage absorptionlaunched voltage regulator dynamic coefficient of static coefficient Regulators are filling state timeand state absorption time.
y Do not brown-out real-time clock function, display and set the clock;y Lightning: According to system requirements, install different levels of mine devices;
y A temperature compensation function;
y Portfolio ingenious: alone, but also complementary components scenery, inverter control integrationmodels
8/8/2019 Characters Tic of Charge Controller
18/58
8/8/2019 Characters Tic of Charge Controller
19/58
Block diagram of the inverter
8/8/2019 Characters Tic of Charge Controller
20/58
On the load configurationy Equipment (or other electrical appliances used) on the plate are
generally rated current, voltage data, they are multiplied together toreceive VA value corresponding power. Users must use carefully inspectthe load power in order to avoid overload. With the general operationof electrical appliances in the state, especially in the standby powerthan the actual state of the mark on some low power users to be used inthe use of electrical appliances and of the nominal power, is starting atthe same time consider the impact of current, best left 30 % of thepower cushion to ensure reliable power supply;
y The load should be considered motor-5 ~ 7 times thecushion to impact current.
8/8/2019 Characters Tic of Charge Controller
21/58
Inverter Power protectionprotection instruction remarks
Output Over-load
protectionPower load more than 150%, 10 seconds
after the shutdown output delayNeed to be resetshutdownShort circuit
protection If the output short circuit, inverter power will be
shut down automatically
To protect
against the
importation
Input DC voltage inverter to the anti-polarity, the
inverter will be automatically protected
Automatically
reset, that is, afterthe failure to
eliminate the
output will
automatically
resume
Under-voltage Input DC voltage is lower than the under voltage
point, inverter power will be shut downautomatically
Over voltageInput DC voltage is higher than the pressure point,
inverter power will be shut down automatically
Over heating
protectionInverter Power Supply chassis temperature over
75, the output will be shut down automatically
8/8/2019 Characters Tic of Charge Controller
22/58
The discharged protection and recoveryy Protection of the over-discharged, the battery voltage required to return to work at 226 V or
above can start again. Backlash is set up in order to prevent voltage under voltage system in
the near oscillations, as shown in Figure 6.1.
y Power attention when booting the first time if the battery voltage is in the release point andresume work between power will be in the state and show under voltage shutdown.
y Over-discharged protection value and the restoration of working voltage values for the
default settings (subject to user requirements set), general without adjustment. If and whereadjustments, in the PC board (SNMC) found on the potential for VR2 (Figure 7.3 Position6), such as lowering the release point, then clockwise adjustment; such as raising the releasepoint, the anti-clockwise adjustment. Potentiometer adjustment semi-circle, thecorresponding change in value of the release point about 7 V, for reference purposes only.
Picture 6.1Picture 6.1
8/8/2019 Characters Tic of Charge Controller
23/58
8/8/2019 Characters Tic of Charge Controller
24/58
the Maintainability of Photovoltaic power
systems componentsActually in photovoltaic power system , some components can be maintained but some can not be.
Such as solar panels, maintenance-free batteries, they are difficult to repair after the failure, whichis called as the non-maintenance components, which are directly dealt with a narrow reliability index,the main reliability, failure rate, the average life expectancy of three indicators, reliability, R (t) refersto products (or parts) under the conditions set forth in that time to complete the function of the
probability of failure rate (t) refers to the moment t work has not yet Failure products, in themoment unit time in the probability of failure; average life expectancy refers to the use of products fromthe beginning until failure occurred experienced by time.
The controller, inverter power supply can be maintained, such as products or components, and itsmain indicators reliability, failure rate and the average time between failures (MTBF) and mean time torepair faults (MTTR).
The components can be maintained and by the maintenance of the components of PV systems, in
general, should be understood as products can be maintained.
8/8/2019 Characters Tic of Charge Controller
25/58
The designing of the PV Grid-Off systemCasey Requirements: computers, lighting, radar (emotional) of load, time
uncertain, the daily power consumption about 200 KWH batteries topower for three days cloudy.
1. Battery configuration (in accordance with the allocation of work for three rainy days):
Battery groups voltage: 220VCapacity needs:(daily needed electricity rainy days 1000) / (battery voltage discharge capacity)
Discharge capacity:In the process of battery usage, the battery capacity released by the percentage of its
rated capacity, known as the discharge capacity. Discharge capacity to the protection ofsmall batteries, the election is generally recommended 0.5
(200 3 1000) / (220 * 0.5 * 0.9) = 5754 AHchoose 2 V1000AH battery of a total of five groups of110pcs, a total of 550pcs.
8/8/2019 Characters Tic of Charge Controller
26/58
The designing of the PV Grid-Off system
y 2. Solar array configurations:Need to configure the maximum power to maintain voltage in the vicinity of220V , Selection of 85 Wp (or other specifications): open-circuit voltage of 22 V,maximum power point voltage of17.5, short-circuit current of 545 A.
Configured 220/12 = 18pcs connected in series. Each series power is 18 85 =1530Wp. Each series in accordance with the full power operation of 3.2 hours,each providing 3.2 1530 = 4896 KWH electricity.
Need solar parallel: the daily consumption / (n = array electricity efficiency)
At: 200 / (4.9 * 0.85) = 48 Unit: 0.85 controller for solar and other conductors,such as the efficiency losses.
The total need to configure 48 18 = 864pcs 85 Wp solar panel
8/8/2019 Characters Tic of Charge Controller
27/58
The designing of the PV Grid-Off system
y 3. Solar controller configurationAccording to the trade unions and arrays: configuration 9pcs SD22100 solar
controller. Each four-way controller solar arrays.
y 4. Inverter configurationBecause users do not have to provide the power size of the load, in
accordance with the working day to 10 hours to estimate, about 30 KW.
Consider cushion and load activated impact of the proposed configurationSN22050KS power inverter.
Meanwhile, in order to protect key equipment, such as radar and work normally.Recommends that users load individually configured as the key low-powerinverter power, the inverter and battery SN22050KS common DC bus power, thespecific size can be agreed with the users. The low-power inverter can bepurchased as spared machine.
8/8/2019 Characters Tic of Charge Controller
28/58
Grid-connected PV systemRenewable energy grid-connected power generating applications
8/8/2019 Characters Tic of Charge Controller
29/58
Grid-connected PV inverter introduction1HZHVWGHYHORSHG.....NN*ULGFRQQHFWHG,QYHUWHU
8/8/2019 Characters Tic of Charge Controller
30/58
the comparative advantages and disadvantages of the structure and
topology of the common grid-connected inverter
direct inverter systemdirect inverter system
Low-frequencyfrequency
transformertransformer
isolation systemisolation system
8/8/2019 Characters Tic of Charge Controller
31/58
the comparative advantages and disadvantages of the structure
and topology of the common grid-connected inverter
the highthe high--frequencyfrequencyisolation systemisolation system
MultiMulti-- More DCMore DC--DCDC(MPPT), single inverter(MPPT), single inverter
systemsystem
the highthe high--frequencyfrequencynonnon-- isolation systemisolation system
8/8/2019 Characters Tic of Charge Controller
32/58
The advantages and disadvantages of direct inverter
system
Advantages:Advantages:Eliminates cumbersome Frequency Transformer: high efficiency (96 %), light weight,Eliminates cumbersome Frequency Transformer: high efficiency (96 %), light weight,
simple structure.simple structure.
Disadvantages:Disadvantages:(1)(1) solar panels and electrical power grids not isolation, solar panels have bipolarsolar panels and electrical power grids not isolation, solar panels have bipolarvoltage power grids, adverse safety.voltage power grids, adverse safety.
(2) DC type solar panels voltage is more than 350 V. This solar components, and(2) DC type solar panels voltage is more than 350 V. This solar components, and
even the entire system of higher insulation requirements prone to leakageeven the entire system of higher insulation requirements prone to leakage
phenomenon.phenomenon.
8/8/2019 Characters Tic of Charge Controller
33/58
The advantages and disadvantages of the Lowe frequency Transformerisolation system
Advantages:Advantages:Using the frequency transformer to change the voltage and isolate the electricity, itUsing the frequency transformer to change the voltage and isolate the electricity, ithas the following advantages: simple structure, high reliability, impact resistance,has the following advantages: simple structure, high reliability, impact resistance,and good safety performance, MPPT DC voltage 200 V rating in the generaland good safety performance, MPPT DC voltage 200 V rating in the general--750V.750V.
Disadvantages:Disadvantages:(1) relatively low system efficiency.(1) relatively low system efficiency.(2) heavy(2) heavy
8/8/2019 Characters Tic of Charge Controller
34/58
The advantages and disadvantages of high-frequency
isolation system
Advantages:Having the advantage of electrical isolation as well as light weight, system efficiency 93%.
Disadvantages:(1) As isolated DC / AC / DC power hierarchy generally smaller, so this topological
structure concentrated in the following 5 KW;(2) high-frequency DC / AC / DC the work of a high frequency, usually dozens
KHz, or higher, it is more difficult for EMC system design;
(3) the impactof poor system.
8/8/2019 Characters Tic of Charge Controller
35/58
The advantages and disadvantages of the high-frequency
isolation system
Advantages:Advantages:
Same as the first topology structure, eliminating cumbersome frequency transformer, we can bring theSame as the first topology structure, eliminating cumbersome frequency transformer, we can bring the
following advantages: high efficiency, light weight. At the same time joined the BOOST circuit for DC /following advantages: high efficiency, light weight. At the same time joined the BOOST circuit for DC /
DC input voltage DC upgrade, solar array DC input voltage range can be very wide (70 VDC input voltage DC upgrade, solar array DC input voltage range can be very wide (70 V--750V).750V).
Disadvantages:Disadvantages:
(1) Similarly, the solar panels and electrical power grids not isolation, solar panels have bipolar voltage(1) Similarly, the solar panels and electrical power grids not isolation, solar panels have bipolar voltage
power grids.power grids.
(2) The use of high frequency DC / DC, EMC become even more difficult.(2) The use of high frequency DC / DC, EMC become even more difficult.
(3) Lower reliability.(3) Lower reliability.
8/8/2019 Characters Tic of Charge Controller
36/58
Multi- More DC-DC (MPPT), single
inverter system
Advantages:y Same as the advantage of the high-frequency isolation systemy Due to a number of DC-DC circuit for a number of different tilt array of
access, that is, 1 ~ n arrays can have different MPPT voltage, verysuitable for photovoltaic building.
Disadvantages:y Not with the high-frequency isolation system
8/8/2019 Characters Tic of Charge Controller
37/58
Using the low frequency transformer High power three-
chase High Power grid-connected Inverter system
Using the low frequency transformer High power threeUsing the low frequency transformer High power three--chasechase
High Power gridHigh Power grid--connected Inverter systemconnected Inverter system 1010--500KW500KW
8/8/2019 Characters Tic of Charge Controller
38/58
multi-level transformation of the High power three-
phase Grid-connected inverter system
8/8/2019 Characters Tic of Charge Controller
39/58
The advantages and disadvantages of single machine connecting
to the Grid
Advantages:y Easy centralized control
y Relatively low cost
y Easy electromagnetic Compatibility
y The better ability of the anti-island effect
Disadvantages:y
Low reliability, high cost of redundancy to achievey As all components of PV series-parallel, the relatively
low efficiency of power generation
y Reduce the relative safety of
8/8/2019 Characters Tic of Charge Controller
40/58
The Way Of Distribution of power, multi-branch Grid-connected
inverter
8/8/2019 Characters Tic of Charge Controller
41/58
8/8/2019 Characters Tic of Charge Controller
42/58
the single-phase grid-connected inverterB
y, Low-frequency transformerisolation
8/8/2019 Characters Tic of Charge Controller
43/58
the single-phase grid-connected inverterB
y DC boost, high-frequencytransformer isolation
8/8/2019 Characters Tic of Charge Controller
44/58
The advantages and disadvantages distribution of power, multi-
branch Grid-connected inverter
y Advantages:y Each array independent of each other, and easy to maintain;y Higher reliability of the whole system;y
Installation flexibility, adaptability good;y Better safety performance;
y Higher utilization of photovoltaic array
y Disadvantages:y Relatively high costy Can be difficult to achieve electromagnetic compatibilityy Require careful design and verification of the ability of anti-island effect
8/8/2019 Characters Tic of Charge Controller
45/58
The way of the grid-connected multi-inverterParallel
8/8/2019 Characters Tic of Charge Controller
46/58
8/8/2019 Characters Tic of Charge Controller
47/58
the advantages and disadvantages of Parallel grid-connected
multi-inverter
y Advantages:y The whole system reliability;
y Installation of a relatively flexible,
y
Applicability good;y Better safety performance;
y High utilization of photovoltaic arrays;
y Algorithm flexible, centralized control;
y Disadvantages:y
Relatively high cost;y Electromagnetic Compatibility difficult to achieve;
y Require careful design and verification of the ability of anti-island effect
8/8/2019 Characters Tic of Charge Controller
48/58
SG series PV Grid-connected Inverter
**GridGrid--connected PV system includes the PV modules, Gridconnected PV system includes the PV modules, Grid--connectedconnected
inverter and network measurement devices and distribution system.inverter and network measurement devices and distribution system.
**Solar cells can generate DC powerSolar cells can generate DC powerelectricity
**The power is changed to the sameThe power is changed to the same-- phase, sine wave current through thephase, sine wave current through the
PV GridPV Grid--connected inverter directly and enters into the power grids.connected inverter directly and enters into the power grids.
8/8/2019 Characters Tic of Charge Controller
49/58
Existing product models and specifications SG1K5TLSG1K5TLSG2K5TLSG2K5TLNonNon--isolatedisolated
SG3KSG3KSG5KSG5KSG6KSG6K
SG10K3SG10K3SG20K3SG20K3SG30K3SG30K3SG50K3SG50K3SG100K3SG100K3
SG200K3SG200K3SG500K3SG500K3
8/8/2019 Characters Tic of Charge Controller
50/58
SG Products Characteristicsy using U.S.A. TI Companys 32 DSP microprocessor control
y using the fifth generation Intelligent Power Module from Mitsubishi.
y maximum power tracking technology (MPPT)
y night zero power technology (single-phase)
y perfect protection (island effect, over-current, over-temperature, etc.)
y stainless steel shell, all enclosed installationSG3K,SG5K,SG6K
y monitoring capabilities improved, through RS485, Ethernet, and othermeans of communication
8/8/2019 Characters Tic of Charge Controller
51/58
SG series PV Grid-connected inverter monitoring software
Interface
8/8/2019 Characters Tic of Charge Controller
52/58
SG series PV grid-connected inverter products pictures
SG1.5KTL PV gridPV grid--connected inverterconnected inverter SG3K PV gridPV grid--connected inverterconnected inverter SG5k,6K indoors typePV gridPV grid--connected inverterconnected inverter
SG5k,6K outdoors typePV gridPV grid--connected inverterconnected inverter
SG30K3SG50K3 three-chasePV gridPV grid--connected inverterconnected inverter
100KW three-chasePV gridPV grid--connected inverterconnected inverter
SG500K large-scale
PV gridPV grid--connected inverterconnected inverter
8/8/2019 Characters Tic of Charge Controller
53/58
8/8/2019 Characters Tic of Charge Controller
54/58
Cases
3kw Grid-connected Solar
PV system forModel
8/8/2019 Characters Tic of Charge Controller
55/58
100KWGrid-connected Roof Solar PV system
8/8/2019 Characters Tic of Charge Controller
56/58
12KW Grid-connected Solar PV system
8/8/2019 Characters Tic of Charge Controller
57/58
Design for the Grid-connected Solar Power System
y The designing of PV Grid-connected system is very
random, can be big, also be small.
y Guangdong region: 1 KWP photovoltaic arrays(conditions: abundant sunshine)Daily 3.2 ~ 3.5 KWH of electricity;
yAnd PV Grid-connect devices and photovoltaic arraysinverter Matching 1:1
8/8/2019 Characters Tic of Charge Controller
58/58