Chapter 14. Principles of Neutralization Titrations. Neutralization titrations are widely used to determine the amounts of acids and bases and to monitor the progress of reactions that produce or consume hydrogen ions. 14 A Solutions and indicators for acid/base titrations - PowerPoint PPT Presentation
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Chapter 14

Chapter 14

Principles of Neutralization Titrations

Page 2: Chapter 14

Neutralization titrations are widely used to determine the amounts of acids and bases and to monitor the progress of reactions that produce or consume hydrogen ions.

14 A Solutions and indicators for acid/base titrations

Neutralization titrations depend on a chemical reaction of the analyte with a standard reagent. There are several different types of acid/base titrations.

1.The titration of a strong acid, such as hydrochloric or sulfuric acid, with a strong base, such as sodium hydroxide. 2.The titration of a weak acid, such as acetic or lactic acid, with a strong base. 3.The titration of a weak base, such as sodium cyanide or sodium salicylate, with a strong acid.

Page 3: Chapter 14

Standard Solutions

The standard reagents used in acid/base titrations are always strong acids or strong bases, such as HCl, HClO4, H2SO4, NaOH, and KOH.

Weak acids and bases are never used as standard reagents because they react incompletely with analytes.

Standard solutions of acids are prepared by diluting concentrated hydrochloric, perchloric, or sulfuric acid.

Nitric acid is seldom used because its oxidizing properties offer the potential for undesirable side reactions.

Hot concentrated perchloric and sulfuric acids are potent oxidizing agents and are very hazardous.

Page 4: Chapter 14

Acid/Base Indicators

An acid/base indicator is a weak organic acid or a weak organic base whose undissociated form differs in color from its conjugate base or its conjugate acid form. For example, the behavior of an acid-type indicator, HIn:

HIn + H2O In- + H3O+

The equilibrium for a base-type indicator, In:In + H2O InH+ + OH-

The equilibrium-constant expression for the dissociation of an acid-type indicator takes the form

Ka = [H3O+][In-]

[HIN]

Page 5: Chapter 14

Figure 14-1 Color change and molecular modes for phenolphthalein. (a) Acidic form after hydrolysis of the lactone form. (b) Basic form.

Page 6: Chapter 14

The human eye is not very sensitive to color differences in a solution containing a mixture of HIn and In2, particularly when the ratio [HIn]/[In2] is greater than about 10 or smaller than about 0.1.

HIn, exhibits its pure acid color when[HIn]/[In-] 10/1

and its base color when [HIn]/[In-] 1/10

Therefore, the range of hydronium ion concentrations needed for the indicator to change color can be estimated. For full acid color,

[H3O+] = 10Ka

and for the full base color,[H3O+] = 0.1Ka

Page 7: Chapter 14

To obtain the indicator pH range, we take the negative logarithms of the two expressions:

pH (acid color) = -log(10Ka) = pKa + 1

pH (basic color) = -log(0.1Ka) = pKa – 1

Indicator pH range = pKa 1

Page 8: Chapter 14

Titration Errors with Acid/Base Indicators

There are two types of titration error in acid/base titrations:

Determinate error that occurs when the pH at which the indicator changes color differs from the pH at the equivalence point.

It can usually be minimized by choosing the indicator carefully or by making a blank correction.

Indeterminate error that originates from the limited ability of the human eye to distinguish reproducibly the intermediate color of the indicator.

The magnitude of this error depends on the change in pH per milliliter of reagent at—the equivalence point, on the concentration of the indicator, and on the sensitivity of the eye to the two indicator colors.

Page 9: Chapter 14

Variables That Influence the Behavior of Indicators

The pH interval over which a given indicator exhibits a color change is influenced by temperature, the ionic strength of the medium, and the presence of organic solvents and colloidal particles.

Some of these effects can cause the transition range to shift by one or more pH units.

Figure 14-2 Indicator color as a function of pH (pKa 5 5.0).

Page 10: Chapter 14

The Common Acid/Base Indicators

Page 11: Chapter 14

14 B Titration of strong acids and bases

The hydronium ions in an aqueous solution of a strong acid have two sources:

(1)the reaction of the acid with water and (2) the dissociation of water itself.

For a solution of HCl with a concentration greater than about 10-6 M:[H3O+] = cHCL + [OH-] cHCL

where [OH2] represents the contribution of hydronium ions from the dissociation of water.

For a solution of a strong base, such as sodium hydroxide:[OH-] = cNAOH + [H3O+] cNAOH

Page 12: Chapter 14

Titrating a Strong Acid with a Strong Base

Three types of calculations must be done to construct the hypothetical curve for titrating a solution of a strong acid with a strong base.

(1)Preequivalence; compute the concentration of the acid from its starting concentration and the amount of base added.(2)Equivalence: the hydronium ion concentration can be calculated directly from the ion-product constant for water, Kw.(3)Postequivalence: the analytical concentration of the excess base is computed, and the hydroxide ion concentration is assumed to be equal to or a multiple of the analytical concentration.

(1) Kw = [H3O+][OH-]

(2) -log Kw = -log [H3O+][OH-] = -log[H3O+] – log[OH-]

(3) pKw = pH + pOH

Page 13: Chapter 14
Page 14: Chapter 14
Page 15: Chapter 14

The Effect of Concentration

The effects of reagent and analyte concentration on the neutralization titration curves for strong acids are shown.

Figure 14-3 Titration curves for HCl with NaOH.

Page 16: Chapter 14

Choosing an Indicator

The selection of an indicator is not critical when the reagent concentration is approximately 0.1 M.

The volume differences in titrations with the three indicators shown are of the same magnitude as the uncertainties associated with reading the buret and so are negligible.

Titrating a Strong Base with a Strong Acid

Titration curves for strong bases are calculated in a similar way to those for strong acids.

Page 17: Chapter 14
Page 18: Chapter 14

Figure 14- 4 Titration curves for NaOH with HCl.

Page 19: Chapter 14

14 C Titration curves for weak acids

Four distinctly different types of calculations are needed to compute values for a weak acid (or a weak base) titration curve:

1.At the beginning, the solution contains only a weak acid or a weak base, and the pH is calculated from the concentration of that solute and its dissociation constant.

2.After various increments of titrant have been added (up to, but not including, the equivalence point), the solution consists of a series of buffers.

The pH of each buffer can be calculated from the analytical concentrations of the conjugate base or acid and the concentrations of the weak acid or base that remains.

Page 20: Chapter 14

3. At the equivalence point, the solution contains only the conjugate of the weak acid or base being titrated (that is, a salt), and the pH is calculated from the concentration of this product.

4. Beyond the equivalence point, the excess of strong acid or base titrant suppresses the acidic or basic character of the reaction product to such an extent that the pH is governed largely by the concentration of the excess titrant.

Page 21: Chapter 14
Page 22: Chapter 14
Page 23: Chapter 14
Page 24: Chapter 14
Page 25: Chapter 14

The analytical concentrations of acid and conjugate base are identical when an acid has been half neutralized.

At the half-titration point in a weak-acid titration, [H3O+] = Ka and pH = pKa

In the titration of a weak base, the hydroxide ion concentration is numerically equal to the dissociation constant of the base at the midpoint in the titration curve.

In addition, the buffer capacities of each of the solutions are at a maximum at this point. These points, often called the half-titration points.

At the half-titration point in a weak-base titration, [OH2] = Kb, and pOH = pKb

Page 26: Chapter 14

The Effect of ConcentrationFigure 14-5 Curve for the titration of acetic acid with sodium hydroxide.

The initial pH values are higher and the equivalence-point pH is lower for the more dilute solution (Curve B).

At intermediate titrant volumes, however, the pH values differ only slightly because of the buffering action of the acetic acid/sodium acetate system that is present in this region.

Page 27: Chapter 14

The Effect of Reaction Completeness

Figure 14-6 The effect of acid strength (dissociation constant) on titration curves.

Titration curves for 0.1000 M solutions of acids with different dissociation constants are shown.

The pH change in the equivalence-point region becomes smaller as the acid becomes weaker.

Page 28: Chapter 14

14D Titration curves for weak bases

Page 29: Chapter 14
Page 30: Chapter 14

Figure 14-7 Hypothetical titration curves for a series of weak bases of different strengths.

The curves show that indicators with mostly acidic transition ranges must be used for weak bases.

Page 31: Chapter 14

14 E The composition of solutions during acid/base titrations

The changes in composition that occur while a solution of a weak acid or a weak base is being titrated can be visualized by plotting the relative equilibrium concentration a0 of the weak acid as well as the relative equilibrium concentration of the conjugate base a1 as functions of the pH

of the solution.

Page 32: Chapter 14

Figure 14-8 Plots of relative amounts of acetic acid and acetate ion during a titration.

The straight lines show the change in relative amounts of HOAc (a0) and OAc2 (a1) during the titration of 50.00 mL of 0.1000 M acetic acid.

The curved line is the titration curve for the system.