Chapter 10 Bioreactor Type and Sterilization
19

Chapter 10sterilization failure ; 1-Po(t) = 1 -[1-P(t)]No= 1 –[1 -exp(-k dt)]No Sterilizationchart 1-P o) kdt Batch vs. continuous sterilization Batch vs. continuous sterilization

Jul 17, 2021

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Chapter 10sterilization failure ; 1-Po(t) = 1 -[1-P(t)]No= 1 –[1 -exp(-k dt)]No Sterilizationchart 1-P o) kdt Batch vs. continuous sterilization Batch vs. continuous sterilization

Chapter 10

Bioreactor Type and Sterilization

Page 2: Chapter 10sterilization failure ; 1-Po(t) = 1 -[1-P(t)]No= 1 –[1 -exp(-k dt)]No Sterilizationchart 1-P o) kdt Batch vs. continuous sterilization Batch vs. continuous sterilization

Type of bioreactors

Stirred-tank reactor

Page 3: Chapter 10sterilization failure ; 1-Po(t) = 1 -[1-P(t)]No= 1 –[1 -exp(-k dt)]No Sterilizationchart 1-P o) kdt Batch vs. continuous sterilization Batch vs. continuous sterilization

Type of bioreactors

Bubble-column reactor

Page 4: Chapter 10sterilization failure ; 1-Po(t) = 1 -[1-P(t)]No= 1 –[1 -exp(-k dt)]No Sterilizationchart 1-P o) kdt Batch vs. continuous sterilization Batch vs. continuous sterilization

Type of bioreactors

Airlift loop reactor

Propeller loop reactor

Jet loop reactor

Page 5: Chapter 10sterilization failure ; 1-Po(t) = 1 -[1-P(t)]No= 1 –[1 -exp(-k dt)]No Sterilizationchart 1-P o) kdt Batch vs. continuous sterilization Batch vs. continuous sterilization

Materials for bioreactors

Page 6: Chapter 10sterilization failure ; 1-Po(t) = 1 -[1-P(t)]No= 1 –[1 -exp(-k dt)]No Sterilizationchart 1-P o) kdt Batch vs. continuous sterilization Batch vs. continuous sterilization

When O2 transfer is limited or cell density is very high:

OUR = OTR

X qo2 = kL a (C* - CL)

OTR [mg O2 / L / h]

kL : oxygen transfer coefficient (cm/h)

a : gas-liquid interfacial area per unit vol. (cm2/cm3)

kL a : volumetric oxygen transfer coefficient (1/h)

C* : saturated DO concentration (mg/L)

CL : DO concentration in the broth (mg/L)

Aeration

When O2 transfer is limited or cell density is very high:

OUR = OTR

X qo2 = kL a (C* - CL)

OTR [mg O2 / L / h]

kL : oxygen transfer coefficient (cm/h)

a : gas-liquid interfacial area per unit vol. (cm2/cm3)

kL a : volumetric oxygen transfer coefficient (1/h)

C* : saturated DO concentration (mg/L)

CL : DO concentration in the broth (mg/L)

Page 7: Chapter 10sterilization failure ; 1-Po(t) = 1 -[1-P(t)]No= 1 –[1 -exp(-k dt)]No Sterilizationchart 1-P o) kdt Batch vs. continuous sterilization Batch vs. continuous sterilization

How to determine kL a

Slope = “-kL a”

ln(C

* -C

L)

t

Page 8: Chapter 10sterilization failure ; 1-Po(t) = 1 -[1-P(t)]No= 1 –[1 -exp(-k dt)]No Sterilizationchart 1-P o) kdt Batch vs. continuous sterilization Batch vs. continuous sterilization

How to determine kL aDynamic method

Bioreactor containing cells

2. Slope = OUR

CL

t1. Stopaeration

3. Resumeaeration

Determined from (4)

5. Finally calculated

known

MeasuredUsing DO probe

= OUR Determined

from (2)

Page 9: Chapter 10sterilization failure ; 1-Po(t) = 1 -[1-P(t)]No= 1 –[1 -exp(-k dt)]No Sterilizationchart 1-P o) kdt Batch vs. continuous sterilization Batch vs. continuous sterilization

Reasons for sterilization

Page 10: Chapter 10sterilization failure ; 1-Po(t) = 1 -[1-P(t)]No= 1 –[1 -exp(-k dt)]No Sterilizationchart 1-P o) kdt Batch vs. continuous sterilization Batch vs. continuous sterilization

Sterilization agents

Page 11: Chapter 10sterilization failure ; 1-Po(t) = 1 -[1-P(t)]No= 1 –[1 -exp(-k dt)]No Sterilizationchart 1-P o) kdt Batch vs. continuous sterilization Batch vs. continuous sterilization

Kinetics of thermal sterilization

Page 12: Chapter 10sterilization failure ; 1-Po(t) = 1 -[1-P(t)]No= 1 –[1 -exp(-k dt)]No Sterilizationchart 1-P o) kdt Batch vs. continuous sterilization Batch vs. continuous sterilization

Kinetics of thermal sterilization

P(t) = Probability that an individual cell is still viable at

sterilization time t

N(t) = # of individuals at time t

No = # of individuals at t=0

kd = specific death rate

P(t) = Probability that an individual cell is still viable at

sterilization time t

N(t) = # of individuals at time t

No = # of individuals at t=0

kd = specific death rate

P(t) = = exp(-kdt) N(t)No

Page 13: Chapter 10sterilization failure ; 1-Po(t) = 1 -[1-P(t)]No= 1 –[1 -exp(-k dt)]No Sterilizationchart 1-P o) kdt Batch vs. continuous sterilization Batch vs. continuous sterilization

Temperature effects on kinetics of thermal sterilization

increasing temperature

-kd

(t)

Page 14: Chapter 10sterilization failure ; 1-Po(t) = 1 -[1-P(t)]No= 1 –[1 -exp(-k dt)]No Sterilizationchart 1-P o) kdt Batch vs. continuous sterilization Batch vs. continuous sterilization

Population effects on kinetics of thermal sterilization

Page 15: Chapter 10sterilization failure ; 1-Po(t) = 1 -[1-P(t)]No= 1 –[1 -exp(-k dt)]No Sterilizationchart 1-P o) kdt Batch vs. continuous sterilization Batch vs. continuous sterilization

Variables for thermal sterilization

Probability of extinction of total population ;

Po(t) = [1-P(t)]No

Probability of unsuccessful fermentation due to

sterilization failure ;

1- Po(t) = 1 - [1-P(t)]No = 1 – [1 - exp(-kdt)]No

Page 16: Chapter 10sterilization failure ; 1-Po(t) = 1 -[1-P(t)]No= 1 –[1 -exp(-k dt)]No Sterilizationchart 1-P o) kdt Batch vs. continuous sterilization Batch vs. continuous sterilization

Sterilization chart1-

Po(

t)1-

Po(

t)

kdt

Page 17: Chapter 10sterilization failure ; 1-Po(t) = 1 -[1-P(t)]No= 1 –[1 -exp(-k dt)]No Sterilizationchart 1-P o) kdt Batch vs. continuous sterilization Batch vs. continuous sterilization

Batch vs. continuous sterilization

Page 18: Chapter 10sterilization failure ; 1-Po(t) = 1 -[1-P(t)]No= 1 –[1 -exp(-k dt)]No Sterilizationchart 1-P o) kdt Batch vs. continuous sterilization Batch vs. continuous sterilization

Batch vs. continuous sterilization

Page 19: Chapter 10sterilization failure ; 1-Po(t) = 1 -[1-P(t)]No= 1 –[1 -exp(-k dt)]No Sterilizationchart 1-P o) kdt Batch vs. continuous sterilization Batch vs. continuous sterilization

Sterilization of gases