This catalogue gives an overview and tecnical data within the BUS cable range. Chainflex® bus cables are cables for energy chains. There are PVC bus cables, PUR bus cables and TPE bus cables to choose from. http://www.igus.co.uk/wpck/default.aspx?PageNr=2212&CL=GB-en&c=gb&L=en&wt.mc_id=SCRUK
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Cam
era
267
Cable type Jacket Page
FireWire Ready-made cable TPE 268
USB Ready-made cable TPE 272
GigE Ready-made cable TPE 276
FOC Ready-made cable PUR 278
FOC Ready-made cable (Robotics) TPE 282
Coax Ready-made cable TPE 284
Video-/vision-/bus technology (with camera reference list Page 288)
Vid
eo-/
visi
on-/
bus
tech
nolo
gy
chainflex® readycable®
EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:03 Seite 266
More than 6.0 million movements have been successfully tested with the CFBUS.055 in e-chains® with 10 m cable length.
Conductor Fine-wire stranded conductor in especially bending-resistantversion consisting of bare copper wires (following EN 60228).
Core insulation Mechanically high-quality PE mixture.
Core stranding Cores and paires stranded with an especially short pitch length.
Element shield Extremely flexible, tinned copper shield over foil taping. Coverageapprox. 70% linear, approx. 90% optical.
Outer jacket Low-adhesion mixture on the basis of TPE, especially abrasion-resistant and highly flexible, adapted to suit the requirements inenergy chains®. Colour: Red lilac (similar to RAL 4001)
T/R moved -35 °C to +70 °C, minimum bending radius 12,5 x d
T/R fixed -40 °C to +70 °C, minimum bending radius 5 x d
v max. 10 m/s, 6 m/sunsupported/glidinga max. 100 m/s2
Travel distance Freely suspended and gliding travel distances up to 400 m,Class 4
UV-resistant Medium
Nominal voltage 30 V
Testing voltage 500 V
Oil Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (fol-lowing VDMA 24568 with Plantocut 8 S-MB tested by DEA),Class 4.
Flame-retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1
Silicon-free Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992).
UL/CSA Style 1589 and 21371, 30 V, 80 °C
TPE Bus cable FireWire Class 6.4.4 (6 maximum load requirements 4 travel distance up to 400 m 4 oil-resistant)
FireWire cable (IEEE 1394a) for maximum load requirements TPE outer jacket oil-resistant bio-oil-resistant flame-retardant hydrolysis-resistant and microbe-resistant
NFPA Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)
CEI Following CEI 20-35
CE Following 2006/95/EG
DESINA According to VDW, DESINA standardisation
Lead free Following 2011/55/EU (RoHS-II)
Clean room According to ISO Class 1. Outer jacket material complies with CF34.UL.25.04.D, testedby IPA according to standard 14644-1
Typical application area
FireWire cable for use in e-chains® in industrial environments (Technical note Page 543) Transmission lengths of up to 10 m
Test data Page 44 or www.igus.eu/en/test9Camera reference list Page 288
269
CameraFireWire
TPE
CameraFireWire
TPE
CFB
US
CFB
US
... no minimum order quantity ...igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | [email protected] | www.chainflex.eu
950 types from stock no cutting costs ...(for up to 10 cuts of the same type)
EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:03 Seite 268
271
CameraFireWire
TPE
CameraFireWire
TPE
CFB
US
CFB
US
Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.As well available on the roll, in the lengths you require.
eplan download, configuratorwww.igus.eu/en/Vision
Pre-assembled on both sidesPin A/Pin BCFBUS.055 MAT9048624 (2x(2x0,15)C+2x(0,34)C 7,5 42 81
Pre-assembled on both sides Socket B/Socket BCFBUS.055 MAT9048626 (2x(2x0,15)C+2x(0,34)C 7,5 42 81
Pre-assembled on both sides Socket B/Pin BCFBUS.055 MAT9048628 2x(2x0,15)C+2x(0,34)C 7,5 42 81
Connector
Socket A (Connector body) with clip
Socket B (Moulded connector) without clip
Pin A (Pin body) without clip
Pin B (Moulded connector) without clip
Delivery program FireWire (TPE) 12,5 x d
Pre-assembled on both sidesSocket A/Socket ACFBUS.055 MAT9048160 ((2x(2x0,15)C+2x(0,34)C) 7,5 42 81
Pre-assembled on both sides Socket A/Pin ACFBUS.055 MAT9048621 2x(2x0,15)C+2x(0,34)C 7,5 42 81
Pre-assembled on both sides Socket A/Socket BCFBUS.055 MAT9048623 2x(2x0,15)C+2x(0,34)C 7,5 42 81
Pre-assembled on both sidesSocket A/Pin BCFBUS.055 MAT9048625 2x(2x0,15)C+2x(0,34)C 7,5 42 81
Pre-assembled on both sides Pin B/Pin BCFBUS.055 MAT9048627 2x(2x0,15)C+2x(0,34)C 7,5 42 81
Pre-assembled on both sides Pin A/Pin ACFBUS.055 MAT9048620 2x(2x0,15)C+2x(0,34)C 7,5 42 81
Pre-assembled on both sides Pin A/Socket BCFBUS.055 MAT9048622 2x(2x0,15)C+2x(0,34)C 7,5 42 81
Delivery program FireWire (TPE) 12,5 x d
Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.As well available on the roll, in the lengths you require.
eplan download, configuratorwww.igus.eu/en/Vision
Delivery program
Part No.
igus®
Part No.
Number of cores and
conductor nominal cross
section [mm2]
Copper
index
[kg/km]
Weight
[kg/km]
External
diameter
approx. [mm]
Delivery program
Part No.
igus®
Part No.
Number of cores and
conductor nominal cross
section [mm2]
Copper
index
[kg/km]
Weight
[kg/km]
External
diameter
approx. [mm]
TPE Bus cable FireWire Class 6.4.4 (6 maximum load requirements 4 travel distance up to 400 m 4 oil-resistant)
FireWire cable (IEEE 1394a) for maximum load requirements TPE outer jacket oil-resistant bio-oil-resistant flame-retardant hydrolysis-resistant and microbe-resistant
... no minimum order quantity ...igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | [email protected] | www.chainflex.eu
950 types from stock no cutting costs ...(for up to 10 cuts of the same type)270
EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:03 Seite 270
Conductor Fine-wire stranded conductor in especially bending-resistantversion consisting of bare copper wires (following EN 60228).
Core insulation Mechanically high-quality PE mixture.
Core stranding Cores and paires stranded with an especially short pitch length.
Core identification Core 0,5 mm2: red, black. Core 0,08 mm2: white, green (CFBUS.065).Core 0,24 mm2: white, green (CFBUS.066).
Overall shield Extremely bending-resistant braiding made of tinned copperwires. Coverage approx. 70% linear, approx. 90% optical.
Outer jacket Low-adhesion mixture on the basis of TPE, especially abrasion-resistant and highly flexible, adapted to suit the requirements inenergy chains®. Colour: Red lilac (similar to RAL 4001)
T/R moved -35 °C to +70 °C, minimum bending radius 12,5 x d
T/R fixed -40 °C to +70 °C, minimum bending radius 5 x d
v max. 10 m/s, 6 m/sunsupported/glidinga max. 100 m/s2
Travel distance Freely suspended and gliding travel distances up to 400 m,Class 4
UV-resistant Medium
Nominal voltage 30 V
Testing voltage 500 V
Oil Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (fol-lowing VDMA 24568 with Plantocut 8 S-MB tested by DEA),Class 4.
Flame-retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1
Silicon-free Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992).
TPE Bus cable USB Class 6.4.4 (6 maximum load requirements 4 travel distance up to 400 m 4 oil-resistant)
USB cable 2.0 for maximum load requirements TPE outer jacket shielded oil-resistant, bio-oil-resistant flame-retardant hydrolysis-resistant and microbe-resistant
NFPA Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)
CEI Following CEI 20-35
CE Following 2006/95/EG
DESINA According to VDW, DESINA standardisation
Lead free Following 2011/55/EU (RoHS-II)
Clean room According to ISO Class 1. Outer jacket material complies with CF34.UL.25.04.D, testedby IPA according to standard 14644-
Typical application area
USB 2.0 cable for use in e-chains® in industrial environments (Technical note Page 543) Transmission lengths of up to 6 m (CFBUS.065) Transmission lengths of up to 10 m (CFBUS.066)
273
CameraUSBTPE
CameraUSBTPE
Camera reference list Page 288
CFB
US
CFB
US
... no minimum order quantity ...igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | [email protected] | www.chainflex.eu
950 types from stock no cutting costs ...(for up to 10 cuts of the same type)
EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:03 Seite 272
274 275
CameraUSBTPE
CameraUSBTPE
CFB
US
CFB
US
Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.As well available on the roll, in the lengths you require. * CFBUS.066 wird mit Formschrumpfschlauch über USB-Gehäuse geliefert.
eplan download, configuratorwww.igus.eu/en/Vision
Pre-assembled on both sidesUSB Type B/BCFBUS.065 USB9040030 2x0,5+1x(2x0,08))C 5,0 26 45
Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.As well available on the roll, in the lengths you require.
eplan download, configuratorwww.igus.eu/en/Vision
Delivery program
Part No.
igus®
Part No.
Number of cores and
conductor nominal cross
section [mm2]
Copper
index
[kg/km]
Weight
[kg/km]
External
diameter
approx. [mm]
Delivery program
Part No.
igus®
Part No.
Number of cores and
conductor nominal cross
section [mm2]
Copper
index
[kg/km]
Weight
[kg/km]
External
diameter
approx. [mm]
TPE Bus cable USB Class 6.4.4 (6 maximum load requirements 4 travel distance up to 400 m 4 oil-resistant)
USB cable 2.0 for maximum load requirements TPE outer jacket shielded oil-resistant, bio-oil-resistant flame-retardant hydrolysis-resistant and microbe-resistant
... no minimum order quantity ...igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | [email protected] | www.chainflex.eu
950 types from stock no cutting costs ...(for up to 10 cuts of the same type)
EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:04 Seite 274
Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.As well available on the roll, in the lengths you require. * Bitte lesen Sie die Produktbeschreibung zur tordierbaren CFROBOT8.045 Page 248
eplan download, configuratorwww.igus.eu/en/Vision
Pre-assembled on both sidesRJ45 metal/RJ45 metalCFBUS.044 GIG9040001 (4x(2x0,15))C 8,0 35 79
Pre-assembled on both sides RJ45 metal/RJ45 plasticCFBUS.044 GIG9040002 (4x(2x0,15))C 8,0 35 79
Pre-assembled on both sidesRJ45 metal/RJ45 metalCFROBOT8.045* GIG9045001 (4x(2x0,14)C) 8,5 35 65
Pre-assembled on both sides RJ45 metal/RJ45 plasticCFROBOT8.045* GIG9045002 (4x(2x0,14)C) 8,5 35 65
Connector
RJ45 metal 8 poles
RJ45 plastic 8 poles, knurled screws
Delivery program GigE (TPE) 12,5 x dDelivery program
Part No.
igus®
Part No.
Number of cores and
conductor nominal cross
section [mm2]
Copper
index
[kg/km]
Weight
[kg/km]
External
diameter
approx. [mm]
Conductor Fine-wire stranded conductor in especially bending-resistantversion consisting of bare copper wires (following EN 60228).
Core insulation Mechanically high-quality PE mixture.
Core stranding 2 cores each stranded in pairs with short pitch lengths, corepairs also stranded with short pitch lengths.
Core identification Colour code in accordance with DIN 47100
Inner jacket TPE mixture adapted to suit the requirements in energy chains®.
Overall shield Extremely bending-resistant braiding made of tinned copperwires. Coverage approx. 70% linear, approx. 90% optical.
Outer jacket Low-adhesion mixture on the basis of TPE, especially abrasi-on-resistant and highly flexible, adapted to suit the requirementsin energy chains®. Colour: Red lilac (similar to RAL 4001)
T/R moved -35 °C to +70 °C, minimum bending radius 12,5 x d
T/R fixed -40 °C to +70 °C, minimum bending radius 7,5 x d
v max. 10 m/s, 6 m/sunsupported/glidinga max. 100 m/s2
Travel distance Freely suspended and gliding travel distances up to 400 m,Class 4
UV-resistant Medium
Nominal voltage 30 V
Testing voltage 500 V
Oil Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (fol-lowing VDMA 24568 with Plantocut 8 S-MB tested by DEA),Class 4.
Flame-retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1
Silicon-free Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992).
UL/CSA Style 1589 and 21371, 30 V, 80 °C
NFPA Following NFPA 79-2012 chapter 12.9 (starting from manufac-turing date 9/2011)
TPE Bus cable GigE Class 6.4.4 (6 maximum load requirements 4 travel distance up to 400 m 4 oil-resistant)
GigE cable for maximum load requirements Ethernet special cable for maximum load requirements TPE outer jacket oil-resistant flame-retardant hydrolysis-resistant and microbe-resistant
Imag
e ex
emp
lary
.CEI Following CEI 20-35
CE Following 2006/95/EG
DESINA According to VDW, DESINA standardisation
Lead free Following 2011/55/EU (RoHS-II)
Clean room According to ISO Class 1. Outer jacket material complies with CF34.UL.25.04.D, testedby IPA according to standard 14644-
Typical application area
Ethernet cable for use in e-chains® in industrial environments (Technical note Page 543) Transmission lengths of up to 50 m
Camera reference list Page 288
277
CameraGigETPE
CameraGigETPE
CFB
US
CFB
US
... no minimum order quantity ...igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | [email protected] | www.chainflex.eu
950 types from stock no cutting costs ...(for up to 10 cuts of the same type)
EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:04 Seite 276
Harnessed igus® E6 system on a camera application.
Core stranding Hollow cores with integrated FOC-fibres stranded with two strain
Core identification Cores black with white numerals.
Outer jacket Low-adhesion mixture on the basis of PUR, adapted to suit therequirements in energy chains® (following DIN VDE 0282 Part 10).Colour: Jet black (similar to RAL 9005)
T/R moved -20 °C to +60 °C, minimum bending radius 12,5 x d
T/R fixed -25 °C to +60 °C, minimum bending radius 7,5 x d
v max. 10 m/s, 6 m/sunsupported/glidinga max. 20 m/s2
Travel distance Freely suspended and gliding travel distances up to 100 m,Class 3
UV-resistant High
Oil Oil-resistant (following DIN EN 50363-10-2), Class 3.
Offshore MUD-resistant following NEK 606 – status 2009.
Silicon-free Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992).
CE Following 2006/95/EG
Lead free Following 2011/55/EU (RoHS-II)
PUR Fibre optic cable (FOC) Glass fibre Class 6.3.3 (6 maximum load requirements 3 travel distance up to 100 m 3 oil-resistant)
Gradient glass fibre cable 50/125 µm, 62,5/125 µm for high load requirements PUR outer jacket metal-free oil-resistant and coolant-resistant UV-resistant
Fibre optic cable for use in e-chains® in industrial environments Transmission lengths of up to 500 m
Test data Page 44 or www.igus.eu/en/test9Camera reference list Page 288
279
CameraFOCPUR
CameraFOCPUR
CFL
G.2
H
CFL
G.2
H
... no minimum order quantity ...igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | [email protected] | www.chainflex.eu
950 types from stock no cutting costs ...(for up to 10 cuts of the same type)
EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:05 Seite 278
281
CameraFOCPUR
CameraFOCPUR
CFL
G.2
H
CFL
G.2
H
Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.As well available on the roll, in the lengths you require. * FOC patch cable extensions are for protected installation only.** 2 ST coupling pieces needed to be ordered extra, if used as extension cable (MAT0176314).
eplan download, configuratorwww.igus.eu/en/Vision
Pre-assembled on both sides** Connector ST/LCFFLG.2G.50/125 LWL90412399 2 50/125 6,5 12,5 x d
Pre-assembled on both sides Connector ST/STFFLG.2G.50/125 LWL90412400 2 50/125 6,5 12,5 x d
Pre-assembled on both sides Connector LC/LCFFLG.2G.50/125 LWL90412401 2 50/125 6,5 12,5 x d
Pre-assembled on both sides** Connector ST/LCFFLG.2G.62,5/125 LWL90412402 2 62,5/125 6,5 12,5 x d
Pre-assembled on both sides Connector ST/STFFLG.2G.62,5/125 LWL90412403 2 62,5/125 6,5 12,5 x d
Pre-assembled on both sides Connector LC/LCFFLG.2G.62,5/125 LWL90412404 2 62,5/125 6,5 12,5 x d
Connector
Connector ST LC
Tube sinking
Tube sinking
LWL90428935 Closed corrugated tube to feed in Fibre optic cables
(image shown cut open)
Delivery program FOC (PUR) 2 Fibres FOC patch cables for static installation*
Pre-assembled on both sides** Connector ST/LCCFLG.2HG.MF.50/125 LWL90412393 2 50/125 9,0 12,5 x d
Pre-assembled on both sides Connector ST/STCFLG.2HG.MF.50/125 LWL90412394 2 50/125 9,0 12,5 x d
Pre-assembled on both sides Connector LC/LCCFLG.2HG.MF.50/125 LWL90412395 2 50/125 9,0 12,5 x d
Pre-assembled on both sides** Connector ST/LCCFLG.2HG.MF.62,5/125 LWL90412396 2 62,5/125 9,0 12,5 x d
Pre-assembled on both sides Connector ST/STCFLG.2HG.MF.62,5/125 LWL90412397 2 62,5/125 9,0 12,5 x d
Pre-assembled on both sides Connector LC/LCCFLG.2HG.MF.62,5/125 LWL90412398 2 62,5/125 9,0 12,5 x d
Connector
Connector ST LC
Tube sinking
Tube sinking
LWL90428935 Closed corrugated tube to feed in Fibre optic cables
(image shown cut open)
Delivery program FOC (PUR) 2 Fibres
Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.As well available on the roll, in the lengths you require.** 2 ST coupling pieces needed to be ordered extra, if used as extension cable (MAT0176314).
eplan download, configuratorwww.igus.eu/en/Vision
Delivery program
Part No.
igus®
Part No.
Number of fibres Bending
radius
ø
[mm]
Fibre
diameter
[µm]
Delivery program
Part No.
igus®
Part No.
Number of fibres Bending
radius
ø
[mm]
Fibre
diameter
[µm]
PUR Fibre optic cable (FOC) Glass fibre Gradient glass fibre cable 50/125 µm, 62,5/125 µm for high load requirements PUR outer jacket metal-free oil-resistant and coolant-resistant, UV-resistant
Class 6.3.3 (6 maximum load requirements 3 travel distance up to 100 m 3 oil-resistant)
... no minimum order quantity ...igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | [email protected] | www.chainflex.eu
950 types from stock no cutting costs ...(for up to 10 cuts of the same type)280
EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:05 Seite 280
Fibre cable 50/125 µm, 62.5/125 µm special fixed wire elements with ara-mide strain relief.
Core stranding FOC wires stranded with high-tensile aramide dampers aroundthe GRP central element.
Outer jacket Low-adhesion mixture on the basis of TPE, especially abrasion-resistant and highly flexible, adapted to suit the requirements inenergy chains®. Colour: Steel blue (similar to RAL 5011)
T/R moved -20 °C to +60 °C, minimum bending radius twisted 12,5 x d
T/R fixed -25 °C to +60 °C, minimum bending radius 7,5 x d
v max. 10 m/stwisteda max. 10 m/s2
Travel distance Robots and movements in the 3D range, Class 1
Torsion ± 180 °, with 1 m cable length
UV-resistant High
Oil Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (fol-lowing VDMA 24568 with Plantocut 8 S-MB tested by DEA),Class 4.
Silicon-free Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992).
CE Following 2006/95/EG
Lead free Following 2011/55/EU (RoHS-II)
Clean room According to ISO Class 1. Outer jacket material complies withCF9.15.07, tested by IPA according to standard 14644-1
Typical application area
for maximum load requirements with torsion movements almost unlimited resistance to oil, also with bio-oils Indoor and outdoor applications, UV-resistant especially for robots and movements in the 3D range robots, handling
TPE Fibre optic cable, twistable CFROBOT5 Class 7.1.4 (7 maximum load requirements 1 unsupported 4 oil-resistant)
for twistable loads TPE outer jacket oil-resistant biooil-resistant UV-resistant low-temperature-flexible hydrolysis-resistant and microbe-resistant
Imag
e ex
emp
lary
.
283
CameraCFROBOT5
TPE
CameraCFROBOT5
TPE
Fibres identification
CFROBOT5.500 orange with white numbers
CFROBOT5.501 blue with white numbers
Part No. Colour code
Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.As well available on the roll, in the lengths you require.* Bei Verlegung dieser Leitung als Verlängerung müssen zusätzlich 2 ST-Verbinder (MAT0176314, je 1,92 €) bestellt werden.
Pre-assembled on both sides* Connector ST/LCCFROBOT5.501 LWL90422491 2 50/125 8,5 12,5 x d
Pre-assembled on both sides Connector ST/STCFROBOT5.501 LWL90422492 2 50/125 8,5 12,5 x d
Pre-assembled on both sides Connector LC/LCCFROBOT5.501 LWL90422493 2 50/125 8,5 12,5 x d
Pre-assembled on both sides* Connector ST/LCCFROBOT5.500 LWL90422494 2 62,5/125 8,5 12,5 x d
Pre-assembled on both sides Connector ST/STCFROBOT5.500 LWL90422495 2 62,5/125 8,5 12,5 x d
Pre-assembled on both sides Connector LC/LCCFROBOT5.500 LWL90422496 2 62,5/125 8,5 12,5 x d
Connector
Connector ST LC
Tube sinking
Tube sinking
LWL90428935 Closed corrugated tube to feed in Fibre optic cables
(image shown cut open)
Delivery program CFROBOT5 (TPE) 2 Fibres ± 180°Delivery program
Part No.
igus®
Part No.
Number of fibres Bending
radius
ø
[mm]
Fibre
diameter
[µm]
eplan download, configuratorwww.igus.eu/en/Vision
CFR
OB
OT5
CFR
OB
OT5
... no minimum order quantity ...igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | [email protected] | www.chainflex.eu
950 types from stock no cutting costs ...(for up to 10 cuts of the same type)
EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:05 Seite 282
285
CameraCFKoax1
TPE
CameraCFKoax1
TPE
CFK
oax1
CFK
oax1
Conductor Multi-wire; adapted in single-wire diameter and pitch length tosuit the requirements in energy chains®.
Core insulation Special FEP-isolating mixture.
Core stranding Cores stranded in one layer with especially short pitch length.
Identification Coaxial elements Schedule Delivery Program
Element shield Extremely bending-resistant braiding made of tinned copperwires. Coverage approx. 70% linear, approx. 90% optical.
Element jacket TPE mixture adapted to suit the requirements in energy chains®.
Outer jacket Low-adhesion mixture on the basis of TPE, especially abrasion-resistant and highly flexible, adapted to suit the requirements inenergy chains®. Colour: Steel blue (similar to RAL 5011)
T/R moved -35 °C to +100 °C, minimum bending radius 10 x d
T/R fixed -40 °C to +100 °C, minimum bending radius 7,5 x d
v max. 10 m/s, 5 m/sunsupported/glidinga max. 100 m/s2
Travel distance Freely suspended and gliding travel distances up to 400 m,Class 4
UV-resistant High
Nominal voltage 300/300 V (following DIN VDE 0245).
Testing voltage 1500 V
Oil Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (fol-lowing VDMA 24568 with Plantocut 8 S-MB tested by DEA),Class 4.
Silicon-free Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992).
CE Following 2006/95/EG
TPE Coax cable CFKoax1 Class 6.4.4 (6 maximum load requirements 4 travel distance up to 400 m 4 oil-resistant)
75 Ω coax cable for maximum load requirements TPE outer jacket oil-resistant biooil-resistant UV-resistant hydrolysis-resistant and microbe-resistant
Clean room According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPAaccording to standard 14644-1
Info The coax elements used in cables of the CF Koax1 series are comparable with a HF75-0.3/1.6 according to MIL-C-17/94-RG179 and thus fit in an RG179 plug!
Typical application area
for maximum load requirements almost unlimited resistance to oil, also with bio-oils Indoor and outdoor applications, UV-resistant especially for freely suspended and gliding travel distances up to 400 m Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room,
Coax cables and other chainflex® cables in platform technology. e-chain®: System E4/4
... no minimum order quantity ...igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | [email protected] | www.chainflex.eu
950 types from stock no cutting costs ...(for up to 10 cuts of the same type)
EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:05 Seite 284
286 287
CameraCFKoax1
TPE
CameraCFKoax1
TPE
CFK
oax1
CFK
oax1
Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.As well available on the roll, in the lengths you require.
Coaxial elements identification
CFKoax1.05 red, green, blue, white, black
Part No. Colour code
eplan download, configuratorwww.igus.eu/en/Vision
Pre-assembled on both sides Connector/SocketCFKoax1.05 MAT90423405 5 10,0 10 x d 47 135
Pre-assembled on both sides Connector/ConnectorCFKoax1.05 MAT90423406 5 10,0 10 x d 47 135
Pre-assembled on both sides Socket/SocketCFKoax1.05 MAT90423407 5 10,0 10 x d 47 135
Pre-assembled at one end Connector/open end of cableCFKoax1.05 MAT90423408 5 10,0 10 x d 47 135
Pre-assembled at one end Socket/open end of cableCFKoax1.05 MAT90423409 5 10,0 10 x d 47 135
Delivery program CFKoax1 (TPE) 5 coaxial elementsDelivery program
Part No.
igus®
Part No.
Number of coaxial
elements
Copper
index
Bending
radius
External
diameter
approx. [mm]
Weight
[kg/km]
Coaxial elements identification
CFKoax1.01 red
Part No. Colour code
Pre-assembled on both sides Connector/SocketCFKoax1.01 MAT90423400 1 4,5 10 x d 9 25
Pre-assembled on both sides Connector/ConnectorCFKoax1.01 MAT90423401 1 4,5 10 x d 9 25
Pre-assembled on both sides Socket/SocketCFKoax1.01 MAT90423402 1 4,5 10 x d 9 25
Pre-assembled at one end Connector/open end of cableCFKoax1.01 MAT90423403 1 4,5 10 x d 9 25
Pre-assembled at one end Socket/open end of cableCFKoax1.01 MAT90423404 1 4,5 10 x d 9 25
Delivery program CFKoax1 (TPE) 1 coaxial elementDelivery program
Part No.
igus®
Part No.
Number of coaxial
elements
Copper
index
Bending
radius
External
diameter
approx. [mm]
Weight
[kg/km]
Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary.As well available on the roll, in the lengths you require.
eplan download, configuratorwww.igus.eu/en/Vision
TPE Coax cable CFKoax1 Class 6.4.4 (6 maximum load requirements 4 travel distance up to 400 m 4 oil-resistant)
75 Ω coax cable for maximum load requirements TPE outer jacket oil-resistant biooil-resistant UV-resistant hydrolysis-resistant and microbe-resistant
... no minimum order quantity ...igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | [email protected] | www.chainflex.eu
950 types from stock no cutting costs ...(for up to 10 cuts of the same type)
EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 01:05 Seite 286