Centrifugal Pump Performance Curves and Technical Information 50 60 70 80 90 100 110 HEAD (FT) NPSH IN FEET 30 40 50 250mm IMPELLER DIAMETER 9 13/16" H E A D C AP ACITY 20 25 30 35 40 45 PSI 7.5 HP 200 205 210 215 220 225 230 235 240 5 HP 3 HP 245
Centrifugal PumpPerformance Curves and Technical Information
0 20 40 60 80 100 120 140
0
10
20
30
40
50
60
70
80
90
100
110
CAPACITY
HEA
D (F
T)
NPSH
IN FEET
10
20
30
40
50
80,00070,00060,00050,00040,00030,00020,00010,000
160
NPSH REQUIRED
250mm IMPELLER DIAMETER 9 13/16" HEAD CAPACITY
0
5
10
15
20
25
30
35
40
45
GPMLBS./HR.
PSI
7.5 HP
200 205 210 215 220 225 230
235
240
5 HP
3 HP
245
1
Table of ContentsIntroduction ........................................................................................................................2
Pump basics .........................................................................................................................4
Selecting a pump .................................................................................................................5
Pump inquiries application data sheet ...............................................................................7
How to calculate required pressure ....................................................................................8
Determining net positive suction head (NPSH) .................................................................8
Specific gravity and viscosity chart .....................................................................................9
Conversion factors .............................................................................................................10
Vapor pressure chart .........................................................................................................10
Tubing friction loss chart ..................................................................................................11
Fristam centrifugal pump options ....................................................................................12
Pharmaceutical options .....................................................................................................13
Pump Performance Curves: 1750 RPMFP/FPX Composites ..................... 14 FPR Composites ........................... 16701 ............................................... 18711 ............................................... 19721 ............................................... 20 3521 .............................................. 21731 ............................................... 223531 .............................................. 23741 ............................................... 24 1741 .............................................. 253541 .............................................. 26751 ............................................... 27 3451 .............................................. 283551 .............................................. 291051 .............................................. 30 1151 .............................................. 31 1161 .............................................. 32 4001 .............................................. 34
Dimensional DrawingsFP Single Flange .........................................................................................................54 FP Double Flange ........................................................................................................55FPX Single Flange .......................................................................................................56FPX Double Flange .....................................................................................................57FPR Single Flange .......................................................................................................58 FPR Double Flange .....................................................................................................59FPR 4001 Double Flange ............................................................................................60
Pump Performance Curves: 3500 RPMFP/FPX Composite ....................... 35 FPR Composites ........................... 36702 ............................................... 38712 ............................................... 39722 ............................................... 40 3522 .............................................. 41732 ............................................... 421732 .............................................. 43 3532 .............................................. 44742 ............................................... 45 1742 .............................................. 473542 .............................................. 49752 ............................................... 50 3452 .............................................. 513552 .............................................. 52
2
Fristam PrideFristam is a global manufacturer of sanitary centrifugal and positive displacement pumps, mixers and blenders respected for unmatched performance, reliability, and technical superiority.
Fristam manufactured its first pump in 1931. Today, Fristam equipment is used by many of the world’s top dairy, beverage, brewing, bio-pharmaceutical, and food processing companies.
Quality ControlFristam Pumps USA designs, manufactures, and assembles its pumps in the United States. Each component is carefully checked from raw material through final assembly.
The result of this effort is a pump worthy of the valuable product your company produces. To achieve the highest level of quality, Fristam offers the most comprehensive testing and documentation packages in the sanitary pump industry.
High Lifetime ValueThe solid design, precise machining, and robust construction of a Fristam pump ensures efficiency and operational reliability. Fristam pumps simply run better and last longer.
3
Experience and ExpertiseOver the past 100 years, Fristam has built its reputation with experience, attention to detail, and a willingness to adapt to changing needs. Fristam’s strong applications engineering capabilities make it the most reliable source for straight, smart answers to process needs.
Why Customers Choose Fristam
“simply better pumps”
“reliable, dependable”
“high standard for sanitization and performance”
“knowledgeable people who help solve problems”
Dedicated SupportFristam’s dedication and quality service do not end with your initial purchase. An international network of manufacturing facilities, sales offices and distribution supports Fristam’s commitment to customer satisfaction.
Fast Delivery, New SolutionsManufacturing in the United States ensures Fristam customers receive prompt delivery, not lead times measured in months.
Additionally, if a new production challenge arises, Fristam is responsive and able to develop new solutions quickly.
4
Pump Series – FP, FPX, or FPRThe FP, FPX, and FPR Series pumps are manufactured of 316L stainless steel and have the same pump head. The FP incorporates a heavy-duty pedestal flange between the motor and pump head. The FPX is a motor mounted pump used for standard duties. The FPR has a front-loading seal for easy changeout and may be used in place of either the FP or FPX. Double seals are only available in the FP and FPR. The FP is used for vacuum withdrawal, high temperature, high viscosity, aseptic processes and other demanding applications.
Pump Model/Housing SizeFristam offers both volute and non-volute (circular) housings in many sizes to best match different process needs. The 700 and 1700 series pumps are non-volute and designed for lower capacities. Their shorter, steeper curves provide better efficiencies on low flows and superior accuracy when used with control devices. The 1050, 1150, 3400 and 3500 series pumps are volute high capacity pumps. Their long, flat curves provide greater capacity and an ability to provide steady discharge pressure over a wide flow range.
SpeedPumps are sized using two standard speeds, 1750 and 3500 RPM. Speed selection is determined when selecting a housing. The last digit of the Fristam model number indicates the speed. All models ending in 1 are 1750 RPM. All models ending in 2 are 3500 RPM.
EfficiencyThe efficiency of centrifugal pumps varies over the individual curve. The most efficient point of two curves is illustrated in Figure 1. When sizing, it is helpful to select a pump whose curve puts the duty point as close to this bend in the curve as possible.
Impeller SizeWithin a given housing, the impeller diameter will determine the flow and pressure produced. Pressure results from the velocity achieved within the pump. The highest velocity occurs at the tip of the impeller and is directly proportional to the square of the impeller diameter. At a given speed, a larger diameter impeller will impart more velocity and produce more pressure.
HorsepowerHorsepower must be matched to a given duty or duties. The requirements are determined by individual curves. Enough horsepower must be supplied to handle the most demanding duty, often the duty requiring the most flow, pressure or the pumping of the heaviest product.
Net Positive Suction Head (NPSH)Product must be forced into a centrifugal pump for it to function properly. This force is called NPSH. Your process must have sufficient NPSH available to meet or exceed the NPSH required.
SealsFristam offers a wide selection of seals. Most processes require a standard single seal of chrome oxide coated stainless steel on carbon. More difficult applications will require harder seal materials such as silicon carbide. Double seals are used when a flush is required, where abrasion or stickiness is a problem, for vacuum withdrawal or if a sterile barrier is required between the process and atmosphere.
Pump Basics: Background Information
PR
ES
SU
RE
VOLUME
FPR
722
722
3522
FPR
352
2
003.p3 fig.1
Figure 1
5
Special ConsiderationsAll curves are based on 70°F water. If your process involves products under vacuum, with high viscosity, high specific gravity, high temperatures, undissolved solids or entrained air there are special considerations which affect pump selection. In such cases, please consult Fristam Pumps or your local Fristam distributor.
Selecting a Pump Model From the Composite CurvesComposite curves appear at the beginnings of the low- and high-speed sections. To select the correct pump model from the composite curves, find the desired flow rate along the bottom scale and the desired pressure on the left-hand vertical scale. Find the point where the vertical line from the flow rate and a horizontal line from the pressure intersect. The curve immediately above this point will be most suitable.
Selecting a Fristam Pump: A Step by Step Guide
ExampleAs an example, size a pump to pump 50 gallons per minute and generate 135 feet of head. In the composite shown in Figure 2, find the intersection point of 50 GPM on the bottom of the graph and 135 feet on the side. The pump curve directly above the duty point is the 722. In this example, model 742 (the next size larger) might also be considered. A quick review of the duty point on their individual curves reveals the 722 will be more efficient than the 742.
Considering Speed and EfficiencyIf both pumps are the same speed, consider which will be more efficient based on the information discussed in Figure 1. If both a high and low speed pump can handle the duty, the high speed will generally be more economical, but the low speed model may have a lower NPSH requirement.
Choosing Impeller Size and HorsepowerHaving chosen a pump model based on the first two steps, find the specific curve for the pump model chosen. To determine the impeller diameter and horsepower move vertically from the flow and horizontally from the pressure or head desired. Find the intersecting point.
The next higher curve indicates the correct impeller diameter. The diagonal line immediately to the right of the intersection identifies the motor horsepower required.
FPR 3500 RPM Composite Curve
200 400 600 800 1000 1200 1400 1600
1265000206 Rev. ARD 2/08
50 100 150 200 250 300 350 400 450
BAR
FEET
OF H
EAD
0
1
2
3
4
5
6
7
8
9
10
11
12
13
702712
722
742
1742
752
0
400
450
350
250
300
200
150
100
50
LPM
CAPACITY
0
GPM 0
PRES
SURE
Figure 2
6
Seal Selection: Single or DoubleMany applications require only single seals. Double seals are recommended for applications involving:• Abrasive products• Sticky products• Vacuum >14” Hg • Temperature regulation
Seal Selection: MaterialsRecommended seal material configurations: • Simple transfer applications: FR-N-(K)*• Sticky applications: FR-C-(N)*• Pharmaceutical applications, chlorine, brine: C-C-(N)** rotating seal, stationary seal, (flush/double seal) N = Carbon C = Silicon Carbide FR = Chrome Oxide Coated Stainless SteelK = Ceramic
ExampleUsing our previous example of 50 gallons per minute and 135 feet of head, we can determine from Figure 3 that the impeller diameter should be 145 millimeters (5.7 inches). The motor required is 5 horsepower.
Checking NPSH (Net Positive Suction Head)To assure there is sufficient product pressure at the inlet of the pump the suction conditions need to be checked. The NPSH required can be determined by finding the point on the individual pump curve where the vertical line from the desired flow rate intersects the NPSH curve. From this point, a horizontal line to the right will intersect the NPSH scale at the net positive suction head required.*
The procedure for determining the NPSH available is described in the “How To Calculate Required Pressure” section of this book. When the NPSH available is determined, it must meet or exceed the NPSH required for the pump to function properly. If the NPSH available is insufficient, a change to the inlet conditions, an enlarged inlet or another pump selection may be required.
ExampleA 722 pumping 50 GPM against 135 feet of head will require 6 feet or more of NPSH. The installation must provide at least 6 feet of head.
ElastomersViton is the standard seal elastomer and BUNA is standard for the cover gasket. Other materials and combinations are available to meet your application or process needs.
00
60
100
120
140
150
40
20
20 40 60 80 100
10,000 20,000
CAPACITY
30,000 40,000 50,000
120
60,000
HEAD
(FT)
NPSH REQUIRED
10 NPSH IN FEET
5 HP
3 HP
80
7 1/2 HP
140
70,000
150
75,000
145mm IMPELLER DIAMETER 5 11/16" HEAD CAPACITY
2 HP
140
135
130
125
120
115
110
0
GPMLBS./HR.
PSI
10
20
30
40
50
60
Figure 3
*Please note that the NPSH values shown are for full size impellers. Smaller impellers may require somewhat greater NPSH.
7
The following information is required to properly process an inquiry:
Requested by _____________________________________________________ Date __________________________________
Customer _______________________________________________________________________________________________
Address _________________________________________________________________________________________________
Telephone __________________________________ Fax _________________ Email __________________________________
Description of product to be pumped _________________________________________________________________________
_______________________________________________________________________________________________________
Temperature __________ Specific Gravity _____________________________ or Density ________________________ lb./gal.
Viscosity ___________________________________ Centipoise (CPS) or other
Desired Flow Rate ___________________________GPM or lb./hr.
*Discharge Head ____________________________ ft. or PSI
Suction Conditions
Is the pump withdrawing from a vacuum? ________Yes _________No
If so, how much?_____in. Hg.
Is the product level on the inlet side of the pump above or below the center line of the pump inlet?
Above ________________ Below _______________ By how much? ________ in. or ft.
Tubing ______________ in. Diameter __________ Length ______________ No. of elbows _____________ No. of tees
Tubing ______________ in. Diameter __________ Length ______________ No. of elbows _____________ No. of tees
No. of size of valves in suction piping:
____________________ No. __________________ Size (in.)
____________________ No. __________________ Size (in.)
Other equipment in the suction piping _______________________________________________________________________
_______________________________________________________________________________________________________
*If you do not know the desired discharge head, please provide the following:
Discharge Conditions
Is the final destination of the pump above or below the center line of the pump inlet?
Above ________________ Below _______________ By how much? ________ in. or ft.
Tubing ______________ in. Diameter __________ Length ______________ No. of elbows _____________ No. of tees
Tubing ______________ in. Diameter __________ Length ______________ No. of elbows _____________ No. of tees
Tubing ______________ in. Diameter __________ Length ______________ No. of elbows _____________ No. of tees
No. and size of valves in discharge piping:
____________________ No. __________________ size (in.)
____________________ No. __________________ size (in.)
____________________ No. __________________ size (in.)
Other equipment and the drop or pressure requirement (PSI) in the discharge piping _________________________________
_______________________________________________________________________________________________________
Pump Inquiry Application Data Sheet
8
20 ft.
10 ft.
299.2 ft.
Outlet1 1/2" Pipe
Open TankWater 62
System HeadThe total head of a system against which a pump must operate is made up of the following components:
1. Static Head2. Difference of pressures existing on the liquids3. Friction
Inlet1 1/2" Pipe8 ft.
Tank180
HeatExchanger
Example: Find the head under these conditions: Pump is drawing from an open tank to discharge through a heat exchanger into an open tank that is 20 ft. above the pump. The supply is 8 ft. above the pump. 50 GPM flow is required.
Solution:1. Height to be pumped is 20 ft. minus 8 ft. =12.0 ft.
2. Friction loss from pipe is (8 ft. + 10 ft. + 20 ft. + 299.2 ft. = 337.2 ft.) 337.2 x .25 ft./ft. =84.3 ft.
3. Friction loss from 3 elbows is = 0.6 ft. = 0.6 ft.
4. *Heat Exchanger loss 2.31 times 16.5 PSI =38.1 ft.
The Total Head Loss is . . . . . . . . . . . . . . . . . . . . 135.0 ft.
*Heat Exchanger information supplied by manufacturer.
How To Calculate Required Pressure
Determining Net Positive Suction Head (NPSH)Fristam pumps are well known for requiring less net positive suction head (NPSH) available than other sanitary centrifugal pumps. However, due to the hydraulic principles involved, some level of NPSH is still required in order for the pump to run efficiently and without cavitating.
The NPSH required for each Fristam pump model has been determined by careful testing. The results of these tests are illustrated by the NPSH curve under the performance curves for each pump model.
To determine the NPSH available, first add the physical height of the liquid above the centerline of the pump inlet to the pressure above the liquid (in an open tank this is atmospheric pressure). From this total, subtract the friction losses of the line and fittings on the suction side and the vapor pressure of the liquid at the operating temperature. The remainder is the NPSH available. This number must meet or exceed the NPSH required in order for the pump to function properly. As an example, figure the NPSH available and required to pump 50 GPM and generate 135 feet water column of pressure.
The pump model required is a 722 with a 145 mm impeller (see “Selecting a Fristam Pump”). From the actual pump curve or from the example in “Selecting a Fristam Pump,” we see that the NPSH required is 3 feet.
Assuming 10 feet of 1 1/2 inch line and one elbow in the suction line, 8 feet of height of liquid above the pump center line and pumping 180°F water from an open tank, we can compute the NPSH available.
NPSH available = Physical height of liquid + atmospheric pressure - friction losses - vapor pressure (see “Vapor Pressure Chart”).
NPSH available = 8 ft. + 33.9 ft. - 4.7ft. - 17.3 ft. = 19.9 ft.
Since the NPSH available of 19.9 feet is greater than the NPSH required 3 feet, the pump has sufficient NPSH available to run properly.
9
Product SP. Visc. Temp Condition Gr. (cps) °F
Acetone 0.80 1 70 Acid: Acetic 1.01 1 100 5% Citric 1.02 1 140 10% Lactic 1.10 1 140 Nitric 1.02 18 70 Alcohol: Ethyl 0.82 1.4 70 Methyl 0.79 0.6 70 Alum 1.33 80 40 50% Conc.
Barbecue Sauce 1.10 150 70 33° Brix Beer 1.02 1 40 Beverage Concentrate 1.26 80 80 Blood 1.00 5 20 Brine 1.10 to 1 40 Sodium Chloride 1.20 1.20Butter–Melted 0.95 90 90 Buttermilk 1.04 20 40 Carbon Tetrachloride 1.59 1 70 Catsup 1.15 100 60 Chocolate Bar Coating 1.08 65 120 Cream 0.99 20 40 40% Fat Dye, Water Base 1.10 10 70 Egg—Whole 1.04 68 40 Egg Yolk 1.12 400 68 200 86 Ethylene Glycol 1.10 18 70 Fat–Animal Melted 0.90 43 110 Glaze–Donut 1.22 55 120 Honey 1.30 230 100 81.2° Brix 1500 70 Ice Cream Mix 1.15 300 40 Varies Ink, Printer’s 1.20 520 130 Juice–Single Strength: Apple, Clear 1.05 20 140 Cranberry 1.03 10 140 Grape 1.05 25 140 Orange 1.05 20 140 Tomato 1.03 180 140
Juice–Concentrate: Apple 1.36 600 50 Thixotropic Cranberry 1.03 250 100 Thixotropic Grapefruit 1000 38 Thixotropic Orange 1.32 5000 38 Thixotropic
Liqueurs 1.15 10 70 Margarine 0.93 50 120 Milk–Whole 1.03 1 40% TS Milk–Concentrated 1.10 1000 50 40% TS 1.30 100 131 75% TS Milk–Concentrated 1.20 20 110 45% TS Skim 1.10 95 70 30% TSMilk–Evaporated 1.17 60 70 48% TSMilk–Skim Condensed 1.20 20 110 45% TS
Product SP. Visc. Temp Condition Gr. (cps) °F
Milk–Sweetened 1.25 2000 50 Condensed 500 150 Milk of Magnesia 1.08 200 70
Oils: Butter 0.90 40 70 Corn 0.93 150 60 Frying 0.90 10 400 Lard 0.96 165 80 Mineral 0.93 150 70 Olive 0.92 110 60 Peanut 0.92 100 60 Soybean 0.93 95 60 Vegetable 0.92 40 100 Paint Solvents 0.90 10 70 Paper Coatings 1.05 400 70 35% TS Paraffin 0.90 9 140 Pear Puree 1.30 4000 160 Thixotropic Perfume 0.95 1 70 Pie Filling 1.20 200 140 Propylene Glycol 1.02 20 30 50%
Sauce–Apple 2000 71 800 190 Salad Dressing 0.96 5000 75 Shampoo 1.00 350 70 Sorbitol 1.30 150 70 75% Soup, Clear 1.00 20 160 Spaghetti Sauce 1.10 200 140 Syrups: Corn 1.39 240 180 40° Be Dextrose 1.35 280 180 77° Brix HFCS 42 1.35 160 70 42% TS HFCS 55 1.35 800 70 55% TS Invert 1.38 800 80 76° Brix Maple 1.37 600 68 Sugar 1.33 220 80 68° Brix Soft Drink 1.26 80 80
Toulene 0.87 1 70 Tomato Paste 1.14 150 75 11% TS 1.14 100 180 11% TS 1.14 1500 200 17% TS Varnish 0.90 125 100 Vinegar 1.01 1 70 Water 1.00 1 70 Includes WFI Wax, Liquid 1.00 75 70 Whey: Acid/Sweet 1.06 2 100 Condensed 1.11 20 100 27% TS 1.20 800 40 40% TS 1.20 400 130 50% TS 1.20 550 65 50% TS 1.24 1500 65 60% TS Sweetened 1.20 900 55 50% TS 1.24 600 145 60% TS Salt 1.06 2 80 Wort 1.05 100 150 Yeast–Brewer’s Fermenting 1.10 150 40 20% TS Yeast Slurry 1.10 270 45 35% TS Yogurt Mix 1.03 20 40
Specific Gravity andViscosity for Various Liquids
Detailed information is available on viscosity correction factors. Contact Fristam Pumps for details. The following viscosities may vary, depending upon products, formulas, and processes used by processors.
10
0 100 200 3002501505032
TEMPERATURE (F)
VAPOR PRESSURE OF WATER
50
40
30
20
10
0
PRESSURE(psia)
Vapor Pressure Chart
Length Meters x 3.281 = Feet Centimeters x 0.394 = Inches Millimeters x 0.0394 = Inches
Mass Kilograms x 2.2 = Lbs. Gallons Of Water x 8.34 = Lbs. Cubic Feet of Water x 62.4 = Lbs. Pounds x 0.454 = Kilograms Volume Liter x 0.264 = Gallon Cubic Feet x 7.48 = Gallon Lbs. Of Water x 0.119 = Gallon Imperial Gallon (British) x 1.2 = Gallon (U.S.) U.S. Gallon x 3.785 = Liter Pressure Feet of Water x 0.433 = PSI Inches of Hg. x 0.491 = PSI Atmosphere x 14.7 = PSI Meters of Water x 1.42 = PSI Kilograms/sq. Centimeter x 14.22 = PSI Bar x 14.7 = PSI
Pressure (continued) Atmosphere x 33.9 = Feet of Water PSI x 2.31 = Feet of Water Inches of Hg. x 1.13 = Feet of Water Flow Lbs. Of Water/Hour x 0.002 = GPM Lbs. Of Fluid/Hour x 0.002 = GPM Specific Gravity Cu. Meter/Hour x 4.4 = GPM Kg. Of Water/Minute x 0.264 = GPM Liters/Minute x 0.264 = GPM GPM x 3.785 = Liters/Minute
Power Liquid HP = GPM x Head ft. x Specific Gravity 3960 BHP = GPM x Head ft. x Specific Gravity 3960 x Pump Efficiency
Viscosity Centipoise = Centistokes Specific Gravity
Centistokes x 4.64 = SSU (Approx.)
Temperature (1.8 X °C) + 32 = °F .555 (°F – 32°) = °C Degrees Kelvin – 273.2 = Degrees Centigrade
Conversion Factors
11
Loss of Head Due to Friction in Feet per Foot of Stainless Steel Tubing and in Feet for Sanitary Fittings
Capacity in O.D. - 1″ O.D. - 1.5″ O.D. - 2″ O.D. - 2.5″ O.D. - 3″ O.D. - 4″ U.S. G.P.M. I.D. - .870″ I.D. - 1.370″ I.D. - 1.870″ I.D. - 2.370″ I.D. - 2.870″ I.D. - 3.834″ Tubing Elbow Tee Tubing Elbow Tee Tubing Elbow Tee Tubing Elbow Tee Tubing Elbow Tee Tubing Elbow Tee 2 .01 .01 .1 4 .025 .02 .2 5 .035 .025 .25 10 .12 .06 .4 .02 .01 .15 .005 .015 .1 15 .25 .1 .8 .04 .02 .25 .013 .02 .15 20 .43 .22 1.5 .06 .03 .3 .02 .025 .2 .005 .02 .1 .003 .02 .06 25 .66 .4 2.3 .08 .04 .4 .025 .03 .25 .006 .03 .15 .004 .03 .08 30 .93 .7 3.3 .105 .06 .55 .035 .05 .3 .008 .05 .2 .005 .04 .1 35 1.22 1.25 5.2 .135 .09 .8 .04 .06 .4 .011 .06 .25 .006 .05 .13 40 .17 .11 1.0 .05 .08 .5 .015 .07 .3 .007 .06 .15 45 .21 .16 1.3 .063 .1 .6 .02 .09 .35 .008 .065 .18 50 .25 .2 1.6 .073 .12 .7 .022 .1 .4 .01 .07 .2 60 .34 .35 2.2 .1 .18 .9 .03 .12 .45 .015 .08 .25 80 .57 .76 3.7 .16 .3 1.5 .05 .15 .55 .02 .1 .4 100 .85 1.35 5.8 .23 .44 2.3 .075 .18 .6 .03 .11 .5 .008 .04 .1 120 1.18 2.05 9.1 .32 .64 3.3 .105 .21 1.0 .04 .13 .6 .01 .05 .15 140 .42 .85 4.5 .14 .23 1.25 .05 .16 .8 .013 .06 .2 160 .54 1.13 5.8 .17 .28 1.6 .07 .2 1.1 .015 .07 .25 180 .67 1.45 7.4 .205 .31 2.0 .08 .21 1.3 .02 .08 .3 200 .81 1.82 9.0 .245 .35 2.5 .1 .26 1.6 .025 .09 .4 220 .95 2.22 11.0 .29 .41 3.0 .12 .3 1.9 .028 .1 .5 240 1.10 2.63 13.5 .34 .48 3.7 .14 .33 2.2 .035 .11 .55 260 .39 .53 4.5 .165 .39 2.5 .04 .115 .6 280 .45 .61 5.3 .19 .42 2.8 .045 .12 .65 300 .515 .7 6.2 .22 .5 3.1 .05 .13 .7 350 .68 1.05 8.5 .28 .67 4.1 .07 .15 .9 400 .86 1.55 11.0 .36 .88 5.2 .085 .18 1.2 450 1.05 2.25 13.5 .44 1.1 6.6 .105 .2 1.5 500 .54 1.4 8.0 .13 .23 1.75 550 .64 1.7 9.5 .15 .27 2.1 600 .75 2.05 10.2 .175 .3 2.5 650 .87 2.41 13.0 .2 .34 2.8 700 1.0 2.8 15.0 .23 .4 3.4 750 .26 .43 3.8 800 .3 .5 4.4 850 .33 .56 5.0 900 .37 .62 5.7 950 .41 .7 6.3 1000 .45 .8 7.0 1100 .53 1.06 8.6
Notes: 1. Flow Elbows—R/D = 1.52. Flow Through Tees—Flow A to B Port C capped off.3. Test Medium—Water at 70°F4. 16 gauge tubing was used for the measurements when the outer diameter (O.D.) was between 1" - 3" and 14 gauge tubing was used with the 4" O.D. measurement.
*Calculated data for estimating purposes only. Consult your tubing manufacturer with specific questions.
C
A
B
12
C – Clamp* B – Bevel seatF – 150# flange3F – 300# flange N – NPT I – I-Line (female)X – Other (specify)
25 – 25 Ra20 – 20 Ra 15 – 15 RaEP – ElectropolishPV – PassivationLF – Low ferriteSF – Stainless steel flangeTC – Tungsten carbide coatingAS – AsepticJH – Jacketed housing CD – Casing drainBB – Bearing block mountedAL – Adjustable base with legsX – Other (specify)
1750 3500RPM RPM
701 702711 712721 7223521 3522731 732++–– 1732++ 3531 3532741 7421741 17423541 3542751+ 752+3451 34523551 35521051 ––1151++ ––1161 ––4001+ ––
+ FPR only++ FP/FPX only
Preferred OrderingSequence (sample)
1st – Rotating2nd – Stationary3rd – Flush (Double) Seal [FP and FPR only]
Single SealFR-N – Chrome oxide SS vs. carbon*C-C – Silicon carbide vs. silicon carbide FR-C – Chrome oxide SS vs. silicon carbide
Double Seal [FP and FPR only]FR-N-K – Chrome oxide SS vs. carbon vs. ceramic*C-C-K – Silicon carbide vs. silicon carbide vs. ceramicFR-C-K – Chrome oxide SS vs. silicon carbide vs. ceramic
FPR 3541 205 3x2.5 C FR-N-K VB 15-EP-SF
MODEL
FITTING TYPE
PORT SIZE
OTHER OPTIONS
SEAL MATERIALS
1st – Inlet (in.)2nd – Outlet (in.)
ELASTOMERS1st – seal (Viton®*)2nd – cover gasket (Buna*) V – Viton®
B – BunaE – EPDMX – Other (specify)
IMPELLER SIZEImpeller diameter (mm)
* Standard
PUMP SERIESFPFPXFPR
Fristam Centrifugal Specialty Pumps• Water for Injection• Aseptic• Jacketed Housing
Fristam Centrifugal Options and Ordering Matrix
13
Pharmaceutical OptionsAll standard stainless steel components are 316L. Special castings are available in low-ferrite stainless steel or high-performance alloys such as Hastelloy® and AL-6XN®. Class VI elastomers are standard for pharmaceutical applications. Seal materials include ceramic and silicon carbide.
Electropolishing and enhanced internal surface finishes to 15 Ra are available on most products.
Casing drain and mounting options provide complete drainability critical for long-term system cleanliness. Pumps can be easily configured for steam-in-place sterilization, with no external cooling devices required.
Water For Injection (WFI) PumpsFristam is the industry leader for WFI and other high-purity service. Fristam WFI centrifugal pumps are a precision adaptation of our FP, FPX, and FPR pumps. They feature an advanced seal design that protects product sterility, saves valuable product and provides for long seal life.
Fristam pioneered a pressurized double seal flush system that ensures product sterility and saves valuable product by maintaining positive pressure in the critical seal area. The internal seal design provides extra cooling and lubrication on the front seal face to significantly extend seal life and provide for more system uptime.
Numerous seal and piping configurations, including single seal piping, are available to meet your processing requirements.
Comprehensive Documentation Options
Certified Drawings
Mill Certification
Physical Certifications
Material Verification
Certificate of Conformance
Warranty Statement
Certified Finish
Passivation of Pump
Stainless Steel Tag
Certified Welding
Hydrostatic Test
Dynamic Seal Test
Short Run Test
Performance Test
NPSH Test
Witness Test
Vibration Test
Ferrite Test
Saline Test
Seismic Calculation
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures. Actual performance may vary by application product. Please contact Fristam for different conditions.
14
FP/FPX Performance CurvesModels: 1750 RPM (Composite A)
CAPACITY
LPM
GPM
0 200 400 600 800 1000 1200
0 50 100 150 200 250 300 350 4000
1
2
3
9/23/021265000074
RD 2/08
FP and FPX 1750 RPM Composite Curves
BAR
FEET
OF H
EAD
701
711
721
731
35213531
3451
3541
741
1741
0
25
50
75
100
PRES
SURE
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures. Actual performance may vary by application product. Please contact Fristam for different conditions.
15
FP/FPX Performance CurvesModels: 1750 RPM (Composite B)
0 800 1600 2400 3200 4000 4800 5600 6400
0 200 400 600 800 1000 1200 1400 1600 1800
CAPACITY
0
1
2
3
4
5
6
9/23/021265000073
RD 2/08
FEET
OF H
EAD
BAR FP and FPX 1750 RPM Composite Curves
0
25
50
75
100
125
150
175
200
1161
1151
10513551
LPM
GPM
PRES
SURE
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures. Actual performance may vary by application product. Please contact Fristam for different conditions.
16
FPR Performance CurvesModels: 1750 RPM (Composite A)
FPR 1750 RPM Composite Curve
BAR
FEET
OF H
EAD
100 200 300 400 500 600 700
0
1
2
3
20 40 60 80 100 120 140 160 180 200
1265000197 Rev. ARD 2/08
0
125
100
75
50
25
1741
751
741
731721
711701
LPM
CAPACITY
0
GPM 0
PRES
SURE
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures. Actual performance may vary by application product. Please contact Fristam for different conditions.
17
FPR Performance CurvesModels: 1750 RPM (Composite B)
FPR 1750 RPM Composite Curve
BAR
FEET
OF H
EAD
800 1600 2400 3200 4000 4800 5600 6400
200 400 600 800 1000 1200 1400 1600 18000
1
2
3
4
5
6
1265000196 Rev. ARD 2/08
0
200
175
125
150
100
75
50
25
40011161
10513551
3541
35313521
3451
0
0
CAPACITY
LPM
GPM
PRES
SURE
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures. Actual performance may vary by application product. Please contact Fristam for different conditions.
18
00
20
18
16
14
12
10
8
6
4
2
95
90
85
80
75
8
6
4
2
08 16 24 32 404 12 20 28 36
4,000 8,000
CAPACITY
GPMLBS./HR. 12,000 16,000 20,000
PSI
HEAD
(FT)
100mm IMPELLER DIAMETER 3 15/16" HEAD CAPACITY
NPSH REQUIRED
5
10
NPSH IN FEET
1/3 HP
1/4 HP
FP/FPX/FPR Performance CurvesModel: 701 (1750 RPM, Inlet 1.5”, Outlet 1.5”)
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures. Actual performance may vary by application product. Please contact Fristam for different conditions.
19
FP/FPX/FPR Performance CurvesModel: 711 (1750 RPM, Inlet 2”, Outlet 1.5”)
00
5
15
20
25
30
10 20 30 40 50
5,000 10,000
CAPACITY
15,000 20,000 25,000
60
30,000
HEAD
(FT)
NPSH REQUIRED
5
10
NPSH IN FEET
1/2 HP
1/4 HP
10
130mm IMPELLER DIAMETER 5 1/8" HEAD CAPACITY
125
120
115
110
100
105
3/4 HP
8
4
0
GPMLBS./HR.
PSI
10
12
6
2
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures. Actual performance may vary by application product. Please contact Fristam for different conditions.
20
FP/FPX/FPR Performance CurvesModel: 721 (1750 RPM, Inlet 2”, Outlet 1.5”)
145mm IMPELLER DIAMETER 5 11/16" HEAD CAPACITY
135
130
125
120
115
110
00
15
25
30
35
40
10
5
10 20 30 40 50
5,000 10,000
CAPACITY
15,000 20,000 25,000
60
30,000
HEAD
(FT)
NPSH REQUIRED
5 NPSH IN FEET
3/4 HP
1/2 HP20
1HP
70
35,000
80
40,000
140
0
GPMLBS./HR.
PSI
16
14
12
10
8
6
2
4
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures. Actual performance may vary by application product. Please contact Fristam for different conditions.
21
FP/FPX/FPR Performance CurvesModel: 3521 (1750 RPM, Inlet 2.5”, Outlet 2”)
00
15
25
30
35
40
10
5
25 50 75 100 125
12,500 25,000
CAPACITY
37,500 50,000 62,500
150
75,000
HEAD
(FT)
NPSH REQUIRED
10 NPSH IN FEET
1/2 HP
1 HP
1 1/2 HP
20
175
87,500
200
100,000
145mm IMPELLER DIAMETER 5 11/16" HEAD CAPACITY
3/4 HP
140
135
130
125
120
115
0
GPMLBS./HR.
PSI
16
14
12
10
8
6
2
4
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures. Actual performance may vary by application product. Please contact Fristam for different conditions.
22
FP/FPX/FPR Performance CurvesModel: 731 (1750 RPM, Inlet 2”, Outlet 1.5”)
00
20
30
40
50
20 40 60 80 100
10,000 20,000
CAPACITY
30,000 40,000 50,000
HEAD
(FT)
10
5
NPSH IN FEET
1/2 HP
10
175mm IMPELLER DIAMETER 6 7/8" HEAD CAPACITY
3/4 HP
1 HP
170
165 160 155
150
NPSH REQUIRED
1 1/2 HP
0
GPMLBS./HR.
PSI
5
10
15
20
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures. Actual performance may vary by application product. Please contact Fristam for different conditions.
23
FP/FPX/FPR Performance CurvesModel: 3531 (1750 RPM, Inlet 2.5”, Outlet 2”)
00
55
20
CAPACITY
HEAD
(FT)
NPSH IN FEET
10
1 HP
1 1/2 HP
2 HP
3 HP
175mm IMPELLLER DIAMETER 6 7/8" HEAD CAPACITY
170
165
160
155
150
145
140
135
130
NPSH REQUIRED
10
20
30
40
50
50 100 150 200 250
25,000 50,000 75,000 100,000 125,000
2750
GPMLBS./HR.
PSI
5
10
15
20
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures. Actual performance may vary by application product. Please contact Fristam for different conditions.
24
FP/FPX/FPR Performance CurvesModel: 741 (1750 RPM, Inlet 2.5”, Outlet 2”)
00
70
30
CAPACITY
HEAD
(FT)
NPSH IN FEET
20
1 HP
1 1/2 HP
2 HP
3 HP
5
10
40
50
60
20 40 60 80 100
10,000 20,000 30,000 40,000 50,000
10
120
60,000
140
70,000
205mm IMPELLER DIAMETER 8 1/16" HEAD CAPACITY
200 195 190 185 180 175 170 165
NPSH REQUIRED
0
GPMLBS./HR.
PSI
5
10
15
20
25
30
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures. Actual performance may vary by application product. Please contact Fristam for different conditions.
25
FP/FPX/FPR Performance CurvesModel: 1741 (1750 RPM, Inlet 2.5”, Outlet 2”)
00
90
30
CAPACITY
HEAD
(FT)
NPSH IN FEET
20
5 HP
1 1/2 HP
2 HP 3 HP
5
10
50
40
70
60
80
40 80 120 160
20,000
20
10,000 40,000 60,000 80,000
60 100 140 180
30,000 50,000 70,000 90,000
10
NPSH REQUIRED
205mm IMPELLER DIAMETER 8 1/16" HEAD CAPACITY
200
195
190
185
180 175
170 165
0
GPMLBS./HR.
PSI
5
10
15
20
25
30
35
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures. Actual performance may vary by application product. Please contact Fristam for different conditions.
26
FP/FPX/FPR Performance CurvesModel: 3541 (1750 RPM, Inlet 3”, Outlet 2.5”)
00
20
CAPACITY
HEAD
(FT)
NPSH IN FEET
10
20
50
40
30
70
60
80
100 200 350
50,000
50
25,000 100,000 175,000
150 250 300 400
75,000 125,000 150,000 200,000
450
225,000
500
250,000
10
NPSH REQUIRED
205mm IMPELLER DIAMETER 8 1/16" HEAD CAPACITY
195
200
185
190
175 180
160
165 170
150
155
0
GPMLBS./HR.
PSI
5
10
15
20
25
30
5 HP
7 HP
3 HP
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures. Actual performance may vary by application product. Please contact Fristam for different conditions.
27
FPR Performance CurvesModel: 751 (1750 RPM, Inlet 3”, Outlet 2”)
0 20 40 60 80 100 120 140
0
10
20
30
40
50
60
70
80
90
100
110
CAPACITY
HEA
D (F
T)
NPSH
IN FEET
10
20
30
40
50
80,00070,00060,00050,00040,00030,00020,00010,000
160
NPSH REQUIRED
250mm IMPELLER DIAMETER 9 13/16" HEAD CAPACITY
0
5
10
15
20
25
30
35
40
45
GPMLBS./HR.
PSI
7.5 HP
200 205 210 215 220 225 230
235
240
5 HP
3 HP
245
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures. Actual performance may vary by application product. Please contact Fristam for different conditions.
28
FP/FPX/FPR Performance CurvesModel: 3451 (1750 RPM, Inlet 3”, Outlet 2”)
00
20
60
80
100
120
50 100 150 200 250
25,000 50,000
CAPACITY
75,000 100,000 125,000
300
150,000
HEAD
(FT)
10
20
NPSH IN FEET
2 HP
3 HP
5 HP
40
NPSH REQUIRED
250mm IMPELLER DIAMETER 9 13/16" HEAD CAPACITY
245 240
235 230 225
220
215 210 205
200 195
0
GPMLBS./HR.
PSI
5
10
15
20
25
30
35
40
45
50
7 1/2 HP
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures. Actual performance may vary by application product. Please contact Fristam for different conditions.
29
FP/FPX/FPR Performance CurvesModel: 3551 (1750 RPM, Inlet 3”, Outlet 2.5”)
00
70
CAPACITY
HEAD
(FT)
NPSH IN FEET
5 HP
15 HP
7 1/2 HP
10 HP
20
40
100
90
80
120
110
130
100 200 35050
50,000 100,000 150,000 200,000 250,000 300,000
150 250 300 400 450 500 550 600 650
60
50
40
30
20
10
NPSH REQUIRED
250mm IMPELLER DIAMETER 9 13/16" HEAD CAPACITY
245 240 235 230 225 220 215 210 205
200
195
0
GPMLBS./HR.
PSI
5
10
15
20
25
30
35
40
45
50
55
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures. Actual performance may vary by application product. Please contact Fristam for different conditions.
30
FP/FPX/FPR Performance CurvesModel: 1051 (1750 RPM, Inlet 4”, Outlet 4”)
00
CAPACITY
HEAD
(FT)
NPSH IN FEET
7 1/2 HP
15 HP
20 HP
10 HP
120
100
80
60
40
20
150 300
75,000 150,000 225,000 300,000 375,000 450,000
450 600 750 900
NPSH REQUIRED
280mm IMPELLER DIAMETER 11" HEAD CAPACITY
275 270
265
260
255
250
245
240
20
10
0
GPMLBS./HR.
PSI
5
10
15
20
25
30
35
40
45
50
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures. Actual performance may vary by application product. Please contact Fristam for different conditions.
31
FP/FPX Performance CurvesModel: 1151 (1750 RPM, Inlet 4”, Outlet 4”)FPR model 1161 covers the range of both the FP/FPX 1151 and 1161
0
0
40
80
120
160
20
60
100
140
180
200
200 400 600 800 1000
100,000 200,000
CAPACITY
300,000 400,000 500,000
HEA
D (F
T)
10
20
NPSH
IN FEET
80
70
60
50
40
30
20
10
0
GPMLBS./HR.
PSI
280mm IMPELLER DIAMETER 11" HEAD CAPACITY 40 HP
10 HP
15 HP 20 HP 25 HP 30 HP
265260255250245240
275270
NPSH REQUIRED
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures. Actual performance may vary by application product. Please contact Fristam for different conditions.
32
FP/FPX Performance CurvesModel: 1161 (1750 RPM, Inlet 4”, Outlet 4”)FPR model 1161 covers the range of both the FP/FPX 1151 and 1161
0
0
40
80
120
160
20
60
100
140
180
200
200 400 600 800 1000
100,000 200,000
CAPACITY
300,000 400,000 500,000
HEA
D (F
T)
10
20
NPSH
IN FEET
80
70
60
50
40
30
20
10
0
GPM LBS./HR.
PSI
315
310 305 300
295
290
285
50 HP
320mm IMPELLER DIAMETER 12 5/8" HEAD CAPACITY
NPSH REQUIRED
40 HP
30 HP
25 HP
20 HP
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures. Actual performance may vary by application product. Please contact Fristam for different conditions.
33
FPR Performance CurvesModel: 1161 (1750 RPM, Inlet 4”, Outlet 4”)FPR model 1161 covers the range of both the FP/FPX 1151 and 1161
Head
Capacity1265000208
Rev. A
100,000
0
lbs /hr
0gpm
0
0200 500
250,000
1000
500,000
240
10
psi
200
feet
50,00
100
150,000
300
100
25
50
75
125
150
175
200,000
400
300,00
600
450,000400,000350,000
700 800 900
20
30
40
50
60
70
80
245250255260265270275280285290
295300305310315320
NPSH
feet
20
10
0
NPSH REQUIRED
10 HP
IMPELLER DIAMETER
HEAD CAPACITY
15 HP
20 HP25 HP
30 HP
40 HP
50 HP
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures. Actual performance may vary by application product. Please contact Fristam for different conditions.
34
FPR Performance CurvesModel: 4001 (1750 RPM, Inlet 6”, Outlet 4”)
0
0
40
80
120
160
20
60
100
140
180
200
400 800 1200 1600 2000
100,000 200,000
CAPACITY
300,000 400,000 500,000
HEA
D (F
T)
10
20
NPSH
IN FEET
80
70
60
50
40
30
20
10
0
GPM LBS./HR.
PSI
360mm IMPELLER DIAMETER 14 13/16" HEAD CAPACITY
NPSH REQUIRED
340
350
330
320
310
300
290
280
40 HP
50 HP
60 HP
75 HP
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures. Actual performance may vary by application product. Please contact Fristam for different conditions.
35
FP/FPX Performance CurvesModels: 3500 RPM (Composite)
BAR FP and FPX 3500 RPM Composite Curves
400 800 1200 1600 2000 2400 2800 3200 3600 4000 4400 4800
50 100 300 500 700 900 1100 1300150 200 400 600 800 1000 12000
2
4
6
8
10
12
6/18/1998il-0364.eps
RD 2/08
FEET
OF H
EAD
450
420
390
360
330
300
270
240
210
180
150
120
30
60
90
0
3552
3452
1742
3542
742
35321732732
722
712702 3522
0
0
CAPACITY
LPM
GPM
PRES
SURE
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures. Actual performance may vary by application product. Please contact Fristam for different conditions.
36
FPR Performance CurvesModels: 3500 RPM (Composite A)
FPR 3500 RPM Composite Curve
200 400 600 800 1000 1200 1400 1600
1265000206 Rev. ARD 2/08
50 100 150 200 250 300 350 400 450
BAR
FEET
OF H
EAD
0
1
2
3
4
5
6
7
8
9
10
11
12
13
702712
722
742
1742
752
0
400
450
350
250
300
200
150
100
50
LPM
CAPACITY
0
GPM 0
PRES
SURE
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures. Actual performance may vary by application product. Please contact Fristam for different conditions.
37
FPR Performance CurvesModels: 3500 RPM (Composite B)
FEET
OF H
EAD
BAR FPR 3500 RPM Composite Curve
400 800 1200 1600 2000 2400 2800
0
8/25/041265000205
RD 2/08
100 200 300 400 500 600 700 8000
50
100
150
200
250
300
350
400
1
2
3
4
5
6
7
8
9
10
11
12
3552
354234523532
3522
LPM
CAPACITY
0
0GPM
PRES
SURE
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures. Actual performance may vary by application product. Please contact Fristam for different conditions.
38
FP/FPX/FPR Performance CurvesModel: 702 (3500 RPM, Inlet 1.5”, Outlet 1.5”)
HEAD
(FT)
0 10 20 30 40 500
90
75
60
45
30
15
35
0
5
10
15
20
25
30
60
5,000 10,000
CAPACITY
GPMLBS./HR. 15,000 20,000 30,00025,000
PSI
NPSH IN FEET
02
46
NPSH REQUIRED
3/4 HP
1 HP
1 1/2 HP
1/2 HP
100mm IMPELLER DIAMETER 3 15/16" HEAD CAPACITY
95
90
85
80
75
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures. Actual performance may vary by application product. Please contact Fristam for different conditions.
39
FP/FPX/FPR Performance CurvesModel: 712 (3500 RPM, Inlet 2”, Outlet 1.5”)
00
20
60
80
100
120
20 40 60 80 100
10,000 20,000
CAPACITY
30,000 40,000 50,000
120
60,000
HEAD
(FT)
NPSH REQUIRED 5
10
NPSH IN FEET
3 HP
2 HP
40
5 HP
130mm IMPELLER DIAMETER 5 1/4" HEAD CAPACITY
125
120
115
110
0
GPMLBS./HR.
PSI
5
10
15
20
25
30
35
40
45
50
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures. Actual performance may vary by application product. Please contact Fristam for different conditions.
40
FP/FPX/FPR Performance CurvesModel: 722 (3500 RPM, Inlet 2”, Outlet 1.5”)
00
60
100
120
140
150
40
20
20 40 60 80 100
10,000 20,000
CAPACITY
30,000 40,000 50,000
120
60,000
HEAD
(FT)
NPSH REQUIRED
10 NPSH IN FEET
5 HP
3 HP80
7 1/2 HP
140
70,000
150
75,000
145mm IMPELLER DIAMETER 5 11/16" HEAD CAPACITY
2 HP
140
135
130
125
120
115
110
0
GPMLBS./HR.
PSI
10
20
30
40
50
60
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures. Actual performance may vary by application product. Please contact Fristam for different conditions.
41
FP/FPX/FPR Performance CurvesModel: 3522 (3500 RPM, Inlet 2.5”, Outlet 2”)
00
60
100
120
140
160
40
20
50 100 150 200 250
25,000 50,000
CAPACITY
75,000 100,000 125,000
300
150,000
HEAD
(FT)
NPSH REQUIRED
40
20
NPSH IN FEET
10 HP
3 HP
7 1/2 HP
5 HP80
350
175,000
400
200,000
145mm IMPELLER DIAMETER 5 11/16" HEAD CAPACITY
140
135
130
125
120
115 15 HP
0
GPMLBS./HR.
PSI
10
20
30
40
50
60
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures. Actual performance may vary by application product. Please contact Fristam for different conditions.
42
FP/FPX Performance CurvesModel: 732 (3500 RPM, Inlet 2.5”, Outlet 2”)FPR model 742 covers the range of both the FP/FPX 732 and 742
0
0
75
125
150
175
200
50
25
25 50 75 100 125
12,500 25,000
CAPACITY
37,500 50,000 62,500
150
75,000
HEA
D (F
T)
NPSH REQUIRED
5
10
NPSH
IN FEET
3 HP
7 1/2 HP
10 HP
100
175
87,500
200
100,000
5 HP
165mm IMPELLER DIAMETER 6 1/2" HEAD CAPACITY
160
155
150
145
140
135
130
125
120
80
70
60
50
40
30
20
10
0
GPM LBS./HR.
PSI
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures. Actual performance may vary by application product. Please contact Fristam for different conditions.
43
FP/FPX Performance CurvesModel: 1732 (3500 RPM, Inlet 2.5”, Outlet 2”)FPR model 1742 covers the range of both the FP/FPX 1732 and 1742
0 0
90
150
180
210
225
60
30
50 100 150 200 250
25,000 50,000
CAPACITY
75,000 100,000 125,000
300
150,000
HEAD
(FT)
NPSH REQUIRED
15
30
NPSH IN FEET
15 HP
120
20 HP
350
175,000
375
10 HP
165mm IMPELLER DIAMETER 6 1/2" HEAD CAPACITY
160
155
150
145
140
7 1/2 HP
90
10
0
GPM LBS./HR.
PSI
20
30
40
50
60
70
80
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures. Actual performance may vary by application product. Please contact Fristam for different conditions.
44
FP/FPX/FPR Performance CurvesModel: 3532 (3500 RPM, Inlet 2.5”, Outlet 2”)
00
225
75
CAPACITY
HEAD
(FT)
NPSH IN FEET
50
15 HP
20 HP
25 HP
30 HP
7 1/2 HP
5 HP
25
50
125
100
175
150
200
100 200 300 400
50,000
50
25,000 100,000 150,000 200,000
150 250 350 450
75,000 125,000 175,000 225,000
25
NPSH REQUIRED
175mm IMPELLER DIAMETER 6 7/8" HEAD CAPACITY
170
165
160
155
150
145
140
135
130
10 HP
90
10
0
GPMLBS./HR.
PSI
20
30
40
50
60
70
80
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures. Actual performance may vary by application product. Please contact Fristam for different conditions.
45
FP/FPX Performance CurvesModel: 742 (3500 RPM, Inlet 2.5”, Outlet 2”)FPR model 742 covers the range of both the FP/FPX 732 and 742
0
0
CAPACITY
HEA
D (F
T)
NPSH
IN FEET
300
250
200
150
100
50
30 60
15,000 30,000 45,000 60,000 75,000 90,000
90 120 150 180
NPSH REQUIRED
10
5
205mm IMPELLER DIAMETER 8 1/16" HEAD CAPACITY
200
195 190
185
180
175 170
120
10
0
GPM LBS./HR.
PSI
20
30
40
50
60
70
80
90
100
110
7 1/2 HP
10 HP
15 HP
20 HP
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures. Actual performance may vary by application product. Please contact Fristam for different conditions.
46
FPR Performance CurvesModel: 742 (3500 RPM, Inlet 2.5”, Outlet 2”)FPR model 742 covers the range of both the FP/FPX 732 and 742
160
125
62,500
gpm
lbs /hr
0
12,5000
00
25
37,50025,000
50 75
50,000
Capacity
100
40 120
20 50
Head 60
140
130100125
135
150150145
155
3 HP
5 HP
7.5 HP
87,50075,000
150
100,000
8/25/041265000207
175 2000
NPSH
10
5
feet
IMPELLER DIAMETER
195250
80
100
175
165
200170
185180
190
120
psi
205200
300
feet
10 HP
HEAD CAPACITY
20 HP
15 HP
NPSH REQUIRED
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures. Actual performance may vary by application product. Please contact Fristam for different conditions.
47
FP/FPX Performance CurvesModel: 1742 (3500 RPM, Inlet 2.5”, Outlet 2”)FPR model 1742 covers the range of both the FP/FPX 1732 and 1742
0
0
350
150
CAPACITY
HEA
D (F
T)
NPSH
IN FEET
100
10 HP
15 HP 20 HP
25 HP 30 HP
50 HP
40 HP
10
20
200
250
300
100 200 300 400 500
50,000 100,000 150,000 200,000 250,000
50
600
300,000
700
350,000
NPSH REQUIRED
205mm IMPELLER DIAMETER 8 1/16" HEAD CAPACITY
200
195
190
185
180
175
170
150
10
0
GPM LBS./HR.
PSI
20
30
40
50
60
70
80
90
100
110
120
130
140
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures. Actual performance may vary by application product. Please contact Fristam for different conditions.
48
FPR Performance CurvesModel: 1742 (3500 RPM, Inlet 2.5”, Outlet 2”)FPR model 1742 covers the range of both the FP/FPX 1732 and 1742
Head
Capacity8/26/04
1265000209
50,000
0
lbs /hr
0gpm
0
0100 250
125,000
500
250,000
140
20
60
40
150
100
80
200
120
psi
250
350
feet
25,000
50
75,000
150
7.5 HP
NPSH
feet
10
0
100,000
200
150,000
300
200,000175,000
350 400
225,000
450
300
20
140
145150155160 10 HP
15 HP
20 HP
165170175
180
185190
195200
205
25 HP 30 HP40 HP
50 HP
50
100
NPSH REQUIRED
IMPELLER DIAMETER
HEAD CAPACITY
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures. Actual performance may vary by application product. Please contact Fristam for different conditions.
49
FP/FPX/FPR Performance CurvesModel: 3542 (3500 RPM, Inlet 3”, Outlet 2.5”)
00
300
80
CAPACITY
HEAD
(FT)
NPSH IN FEET
40 25
160
120
240
200
280
200 300 500 700
100,000
100
50,000 150,000 250,000 350,000
800
400,000
900
450,000
400 600
200,000 300,000
NPSH REQUIRED
205mm IMPELLER DIAMETER 8 1/16" HEAD
195
200
185
175
180
160
165 170
150
120
10
0
GPMLBS./HR.
PSI
20
30
40
50
60
70
80
90
100
110
155
10 HP
15 HP
20 HP
40 HP
50 HP
30 HP
10 HP
15 HP
20 HP
25 HP
40 HP
50 HP
30 HP 190
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures. Actual performance may vary by application product. Please contact Fristam for different conditions.
50
FPR Performance CurvesModel: 752 (3500 RPM, Inlet 3”, Outlet 2”)
0 50 100 150 200 250 300
0
50
100
150
200
250
300
350
400
450
500
CAPACITY
HEA
D (F
T)
NPSH
IN FEET
10
20
30
40
50
60
70
80
90
100
175,00025,000 50,000 75,000 100,000 125,000 150,000
350
NPSH REQUIRED
250mm IMPELLER DIAMETER 9 13/16" HEAD CAPACITY
0
20
GPMLBS./HR.
PSI
40
60
80
100
120
140
160
180
200
245
235
225 220 215 210 205
200
240
40 HP
30 HP25 HP
20 HP
15 HP
50 HP
230
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures. Actual performance may vary by application product. Please contact Fristam for different conditions.
51
FP/FPX/FPR Performance CurvesModel: 3452 (3500 RPM, Inlet 3”, Outlet 2”)
00
150
250
300
350
400
100
50
100 200 300 400 500
50,000 100,000
CAPACITY
150,000 200,000 250,000
600
300,000
HEAD
(FT)
NPSH REQUIRED 20
NPSH IN FEET
20 HP
25 HP
30 HP
15 HP200
700
350,000
800
400,000
250mm IMPELLER DIAMETER 9 13/16" HEAD CAPACITY
40 HP
50 HP
245 240 235 230 225 220 215
210
205
200
195
170
10
0
GPMLBS./HR.
PSI
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
Performance curve based on tests using 70°F water and 0 psig inlet pressure. A tolerance of ± 5% applies to all figures. Actual performance may vary by application product. Please contact Fristam for different conditions.
52
FP/FPX/FPR Performance CurvesModel: 3552 (3500 RPM, Inlet 3”, Outlet 2.5”)
00
100
200
300
400
500
150 300 450 600 750
75,000 150,000
CAPACITY
225,000 300,000 375,000
HEAD
(FT)
25
50
NPSH IN FEET
0
GPMLBS./HR.
PSI
20
40
60
80
100
120
140
160
180
200
250mm IMPELLER DIAMETER 9 13/16" HEAD CAPACITY
NPSH REQUIRED
25 HP
75 HP
60 HP
50 HP
40 HP
30 HP
245
240
235
230 225 220 215
210 205 200 195
53
54
FP Single Flange Dimensional DrawingAll pump dimensions are in millimeters (inches). Dimensions are based on clamp fittings. Motor dimensions may vary by manufacturer.
J198
(7.80")
C
180(7.09") F
E356
(14.00")
36(1.42") X 16(.63") SLOT(4 PLACES) 38 (1.50")
MAX. ADJ.
98(3.88")
180(7.09")
A
H B
ØG
INLET
210(8.27")
203(8.00")
ADJ. LEGS(OPTIONAL)
OUTLET
1265000384 REV-
ØK
D
108(4.25")
144 (5.67")
195(7.68")
200(7.87")
191(7.52")
211(8.31")
190(7.48")
170(6.69")
211(8.31")
2"2.5"FP 741 / 732 / 742
FP 3451 / 3452 3" 2"
FP 3521 / 3522
FP 3531 / 3532
FP 3541 / 3542
FP 1741 / 1732 / 1742
2"2.5"
2.5"
3"
2"
2.5"
2.5" 2"
INLETPUMP MODEL OUTLET
FP 711 / 712
FP 721 / 731 / 722
FP 701 / 702
1.5"2"
2" 1.5"
1.5" 1.5"
181(7.13")
149(5.87")
141(5.55")
270(10.63")
101(3.98")
96(3.78")
158.5(6.24")
170(6.69")
170(6.69")
170(6.69")
166(6.54")
162(6.38")
118(4.64")
115(4.53")
114(4.49")
140(5.51")
158(6.22")
104(4.09")
115.5(4.55")
118(4.64")
80(3.15")
95(3.74")
91(3.58")
162(6.38")
162(6.38")
150.5(5.93")
202(7.95")
290(11.42")
350(13.78")
198(7.80")
230(9.06")
270(10.63")
260(10.24")
202(7.95")
202(7.95")
190.5(7.50")
154.5(6.08")
158(6.22")
158(6.22")
DIMENSIONS IN MILLIMETERS (INCHES)
108.5(4.27")
113(4.45")
113(4.45")
58(2.28")
79(3.11")
44.5(1.75")
A B
150(5.90")
150(5.90")
146.5(5.77")
C D150
(5.90")185
(7.28")230
(9.06")
190(7.48")
190(7.48")
186.5(7.34")
E F ØG
157(6.19")
252(9.94")
115(4.53")
388(15.27")10 HP 215TC
189(7.46")
15 HP10 HP 215TC189
(7.46")416
(16.40")
1.5 HP
2 HP
3 HP
7.5 HP
5 HP
7.5 HP7.5 HP
3 HP
5 HP
2 HP
1.5 HP
1 HP
313(12.31")
133(5.23")
184TC
213TC
182TC
184TC
386(15.18")
152(6.00")
189(7.46")
388(15.27")
152(6.00")
348(13.68")
145TC
145TC
145TC
143TC
284(11.19")
133(5.22")
133(5.22")
284(11.19")
133(5.22")
259(10.19")
263(10.34")
263(10.34")
216(8.50")
216(8.50")
263(10.34")
216(8.50")
183(7.19")
183(7.19")
183(7.19")
DIMENSIONS INMILLIMETERS (INCHES)
0.5 HP
0.75 HP
3500 RPM
MOTOR HP
1 HP
0.75 HP
1750 RPM
MOTOR FRAME
56C
56C
56C
115(4.53")
115(4.53")
236(9.29")
236(9.29")
H115
(4.53")
J236
(9.29")157
(6.19")157
(6.19")
157(6.19")
ØK
1265000385 REV-
55
BALDOR
ØK
J L D
C
INLET
F300
(11.81")559
(22.00") E
19(.75") X 35(1.38") SLOT(4 PLACES)
250(9.84")
M
N
290(11.42")
300(11.81")
A
H B
ADJ. BASE(OPTIONAL)
OUTLET
ØE
1265000386 REV-
FP 1161
FP 1051
FP 1151
PUMP MODEL
FP 3551 / 3552
FP 1732 / 1742
FP 3452
FP 3542
FP 3532
FP 1161
406(15.98")
170(6.69")
250(9.84")
146(5.75")
110.5(4.35")
115(4.53")
211(8.31")
3" 2.5"
3" 2"
231(9.09")
211(8.31")
140(5.51")
140(5.51")
2.5" 2"
2.5" 2"
3" 2.5"
6" 4"
4" 4"
195(7.68")
96(3.78")
191(7.52")
95(3.74")
250(9.84")
250(9.84")
170(6.69")
170(6.69")
164.5(6.48")
290(11.42")
118(4.64")
350(13.78")
350(13.78")
160.5(6.32")170.5(6.71")
119(4.68")
114(4.49")
406(15.98")
406(15.98")
260(10.24")
270(10.63")
101(3.98")
143.5(5.65")
164.5(6.48")
115.5(4.55")
146(5.75")
146(5.75")
111(4.37")
110.5(4.35")
DIMENSIONS IN MILLIMETERS (INCHES)OUTLETINLET
4"4"
4" 4"
250(9.84")
A170
(6.69")
B406
(15.98")202.5(7.97")
D167
(6.57")
C ØGMOTOR HP
50 HP
40 HP
25 HP
30 HP
20 HP
15 HP
7.5 HP
10 HP
1750 RPMDIMENSIONS IN MILLIMETERS (INCHES)
189(7.46")
263(10.34")
416(16.40")
588(23.13")
324TSD40 HP
50 HP
326TSD
326TSD
30 HP
324TSD
286TSC
415(16.33")
499(19.66")
588(23.13")284TC
25 HP 284TSC
286TC
256TC
254TC
395(15.56")
336(13.25")
263(10.34")
333(13.12")
333(13.12")
239(9.42")
220(8.67")
388(15.27")
MOTORFRAME3500 RPM
213TC
215TC
263(10.34")
J ØK
189(7.46")
H
200(7.87")
200(7.87")
200(7.87")
200(7.87")
200(7.87")
200(7.87")
L
FP 742 2"2.5"
200(7.87")
91(3.58")
270(10.63")
153(6.02")
104(4.09")
279.5(11.00")
285.5(11.24")
275.5(10.85")
258.5(10.18")
268(10.55")
E317.5
(12.50")261
(10.28")
F
117(4.62")
M
44.5(1.75")
N
20 HP225
(8.88")256TC491
(19.34")263
(10.34")200
(7.87")
395(15.56")
117(4.62")
44.5(1.75")
98(3.88")
38(1.50")
98(3.88")
38(1.50")
117(4.62")
44.5(1.75")
117(4.62")
44.5(1.75")
117(4.62")
117(4.62")
44.5(1.75")
44.5(1.75")
117(4.62")
44.5(1.75")
**
* 3551 ONLY ** 3551, 1051 & 1151 ONLY *** 117 (4.62") FOR 1051, 1151 & 1161**** 44.5 (1.75") FOR 1051, 1151 & 1161
**
***
*** ****
****
261(10.28")
279.5(11.00")
261(10.28")
200(7.87")
220(8.66")
220(8.66")
220(8.66")
220(8.66")
200(7.87")
333(13.12")
588(23.13")
395(15.56")
333(13.12")
588(23.13")
395(15.56")
333(13.12")
588(23.13")
395(15.56")
333(13.12")
588(23.13")
395(15.56")
333(13.12")
588(23.13")
395(15.56")
333(13.12")
588(23.13")
395(15.56")
254(10.00")197.5(7.78")
195(7.68")204.5(8.05")
216(8.50")
212(8.35")
222(8.74")
197.5(7.78")
216(8.50")
197.5(7.78")
98(3.88")
38(1.50")
98(3.88")
38(1.50")
98(3.88")
38(1.50")
44.5(1.75")
117(4.62")
1265000387 REV-
216(8.50")3 HP
5 HP*
*133
(5.23")182TC313
(12.31")200
(7.87")117
(4.62")44.5
(1.75")263
(10.34")189
(7.46")213TC388
(15.27")200
(7.87")117
(4.62")44.5
(1.75")
FP Double Flange Dimensional DrawingAll pump dimensions are in millimeters (inches). Dimensions are based on clamp fittings. Motor dimensions may vary by manufacturer.
56
FPX Single Flange Dimensional DrawingAll pump dimensions are in millimeters (inches). Dimensions are based on clamp fittings. Motor dimensions may vary by manufacturer.
ØGØE
A
L38 (1.50")MAX. ADJ.
H
J
Q
MK
C
DNF
B
ADJ. LEGS(OPTIONAL)
ØP
INLET
OUTLET
98(3.88")
il-0657
MOTOR HP
7.5 HP
10 HP
20 HP
15 HP
3 HP
1.5 HP
1 HP
5 HP
2 HP
1750 RPM
FPX 3551
FPX 3451 / 3452
FPX 3541 / 3542
FPX 3531 / 3532
FPX 3521 / 3522
FPX 1741 / 1732 / 1742
FPX 741 / 732 / 742
FPX 721 / 731 / 722
FPX 711 / 712
FPX 701 / 702
PUMP MODEL
185(7.28")
150(5.90")
144 (5.67")
58(2.28")
113(4.45")
140(5.51")
140(5.51")
115(4.53")
95(3.74")
80(3.15")
91(3.58")
96(3.78")
79(3.11")
191(7.52")
3"
3"
3"
231(9.09")2.5"
211(8.31")
211(8.31")
2"
2.5"
2.5"
2.5"
2.5"
2.5"
2"
2" 200(7.87")
190(7.48")2"
2"
195(7.68")
170(6.69")
2"
1.5"
260(10.24")
162(6.38")
115.5(4.55")
290(11.42")
350(13.78")
350(13.78")
168(6.61")
119(4.68")
114(4.49")
118(4.64")
158(6.22")
162(6.38")
270(10.63")
270(10.63")
150.5(5.93")
104(4.09")
118(4.64")
162(6.38")
101(3.98")
113(4.45")
141(5.55")
150(5.90")
230(9.06")
230(9.06")
DIMENSIONS IN MILLIMETERS (INCHES)
44.5(1.75")
OUTLETINLET
1.5"
2"
108(4.25")1.5"
1.5"
A B108.5(4.27")
C146.5(5.77")
D150
(5.90")
ØE
121(4.75")
263(10.34")
491(19.34")
13.5(17/32")
169(6.65")
254(10.00")
254(10.00")
225(8.88")
159(6.25")
256TC 499(19.66")
336(13.25")
159(6.25")
239(9.42")
254(10.00")
254(10.00")
13.5(17/32")
169(6.65")
121(4.75")
DIMENSIONS IN MILLIMETERS (INCHES)
183(7.19")
140(5.50")
89(3.50")
216(8.50")
254TC
256TC
213TC
215TC
20 HP
10 HP
447(17.59")
263(10.34")
388(15.27")
263(10.34")
145TC
184TC
182TC
184TC
182TC
7.5 HP
2 HP
3 HP
348(13.69")
386(15.18")
216(8.50")
313(12.31")
183(7.19")
183(7.19")
114(4.50")
140(5.50")
159(6.25")
225(8.88")
133(5.25")
133(5.25")
189(7.46")
210(8.25")
254(10.00")
140(5.50")
216(8.50")
216(8.50")
114(4.50")
114(4.50")
152(5.97")
114(4.50")
89(3.50")
132(5.21")
140(5.50")
140(5.50")
191(7.50")
140(5.50")
145TC
143TC
MOTORFRAME
1.5 HP
3500 RPM281
(11.06")
F183
(7.19")
ØG89
(3.50")
H133
(5.22")
J102
(4.00")
K140
(5.50")
L
70(2.75")
8.7(11/32")
120(4.72")
140(5.53")
89(3.50")
10.3(13/32")
10.3(13/32")
10.3(13/32")
13.5(17/32")
169(6.65")
121(4.75")
140(5.53")
140(5.53")
108(4.25")
108(4.25")
406(16.00")
10.3(13/32")
10.3(13/32")
8.7(11/32")
10.3(13/32")
140(5.53")
89(3.50")
140(5.53")
89(3.50")
140(5.53")
120(4.72")
89(3.50")
70(2.75")
8.7(11/32")
ØP120
(4.72")70
(2.75")
M N Q356
(14.00")281
(11.06")133
(5.22")102
(4.00")281
(11.06")133
(5.22")102
(4.00")
183(7.19")
132(5.21")
140(5.50")
191(7.50")
191(7.50")
191(7.50")
386(15.18")
152(5.97")
388(15.27")
263(10.34")
189(7.46")
140(5.50")
5 HP 114(4.50")
347(13.68")184TC 216
(8.50")152
(5.97")140
(5.50")191
(7.50")140
(5.53")89
(3.50")10.3
(13/32")
15 HP 436(17.15")215TC 263
(10.34")133
(5.25")189
(7.46")140
(5.50")216
(8.50")108
(4.25")140
(5.53")10.3
(13/32")
1265000540
356(14.00")
356(14.00")
356(14.00")
356(14.00")
356(14.00")
356(14.00")
356(14.00")
356(14.00")
356(14.00")
356(14.00")
406(16.00")
406(16.00")
57
BALDOR
ØJ
M PS
ØR
H Q D
C
INLET
K
117.5(4.62")
44.5 (1.75")MAX. ADJ.
N
ADJ. LEGS(OPTIONAL)
ØE
A
BL OUTLET
il-0661
OUTLET
2"
2"
FPX 1161
2.5"FPX 3532
FPX 3542
FPX 3452 3"
3" 2.5"
FPX 1742
FPX 3552
2"2.5"
3" 2.5"
6" 4"
INLETPUMP MODEL
FPX 1151
FPX 1051
118(4.64")
211(8.31")
115(4.53")140(5.51")140(5.51")
231(9.09")
119(4.68")
170.5(6.71")
114(4.49")
160.5(6.32")
91(3.58")
95(3.74")
200(7.87")191
(7.52")
153(6.02")
104(4.09")115.5(4.55")
164.5(6.48")
290(11.42")
350(13.78")
350(13.78")
270(10.63")
260(10.24")
DIMENSIONS IN MILLIMETERS (INCHES)DCBA
110.5(4.35")
146(5.75")
ØE 3500 RPM
25 HP
30 HP
25 HP
1750 RPM
15 HP
20 HP
10 HP
MOTOR HP DIMENSIONS IN MILLIMETERS (INCHES)
279(11.00")
241(9.50")
333(13.11")
178(7.00")
367(14.44")
588(23.13")284TC
286TC
286TSC
284TSC
279(11.00")
159(6.25")
ØJHMOTORFRAME
416(16.40")
499(19.66")
447(17.59")254TC
256TC
215TC
270(10.62")
320(12.60")
263(10.34")
NMLK
226(8.88")239
(9.42")
210(8.25")
254(10.00")
254(10.00")
178(7.00")
216
QP ØR
200(7.87")
S
4" 4"
4" 4"
FPX 1161
4" 4"
250(9.84")
170(6.69")
406(15.98")
250(9.84")
170(6.69")
406(15.98")
250(9.84")
170(6.69")
406(15.98")
250(9.84")
170(6.69")
406(15.98")
167(6.57")
110.5(4.35")
146(5.75")
111(4.37")
146(5.75")
164.5(6.48")
211(8.31")
202.5(7.97")
588(23.13")
367(14.44")
159(6.25")
178(7.00")
333(13.11")
333(13.11")
333
241(9.50")
254(10.00")
279(11.00")
279(11.00")
200(7.87")200
(7.87")200
(7.87")200
(7.87")200
(7.87")200
13.5(17/32")
13.5(17/32")
13.5(17/32")
13.5(17/32")
444(17.50")
470(18.50")
444(17.50")
444(17.50")
444(17.50")
7.5 HP216
(8.50")189(7.46")
140(5.50")
263(10.34")213TC
388(15.27")
133(5.25")
470(18.50")
10.3(13/32")
200(7.87")
30 HP
203(8.00")
636(25.00")40 HP 324TSC
413(16.25")
333(13.11")
267(10.50")
371(14.62")
318(12.50")
13.5(17/32")
200(7.87")
216(8.50")
470(18.50")
108(4.25")
133(5.25")
189(7.46")
216(8.50")
108(4.25")
10.3(13/32")
470(18.50")
121(4.75")121
(4.75")121
(4.75")121
(4.75")121
(4.75")
13.5(17/32")
588(23.13")
367(14.44")
178(7.00")
588(23.13")
367(14.44")
178(7.00")
279(11.00")
279(11.00")
121(4.75")
444(17.50")
133(5.25")
16.7(21/32")
50 HP133(5.25")
203(8.00")
636(25.00")326TSC
413(16.25")
305(12.00")
371(14.62")
318(12.50")
16.7(21/32")
216(8.50")
470(18.50")
133(5.25")
203(8.00")
636(25.00")324TC40 HP
413(16.25")
267(10.50")
371(14.62")
318(12.50")
16.7(21/32")
216(8.50")
470(18.50")
50 HP470
(18.50")16.7
(21/32")216
(8.50")318
(12.50")371
(14.62")305
(12.00")413
(16.25")636
(25.00")203
(8.00")133(5.25")326TC
il-0660
FPX Double Flange Dimensional DrawingAll pump dimensions are in millimeters (inches). Dimensions are based on clamp fittings. Motor dimensions may vary by manufacturer.
58
FPR Single Flange Dimensional DrawingAll pump dimensions are in millimeters (inches). Dimensions are based on clamp fittings. Motor dimensions may vary by manufacturer.
1265000202 Rev A
Q S
W
Z
T D
C
L
M
Ø V
Inlet
Adjustment
YMax. Leg
R
E
X
P
A
B
N
Adjustable Legs(Optional)
Outlet
MOTOR HP MOTORFRAME L M N P Q R S T V W X Y Z PUMP MODEL INLET OUTLET A B C D E
1750 RPM 3500 RPM1 HP 1.5 HP 143TC 284 175 89 133 101.6 140 127 120 8.7 356 98 38 57.2 FPR 701/702 1.5" 1.5" 108 44.5 106.5 139.5 150
11.18" 6.89" 3.5" 5.25" 4" 5.5" 5" 4.72" 0.34" 14" 3.86" 1.5" 2.25" 4.25" 1.75" 4.19" 5.49" 5.91"
1.5 HP 145TC 284 175 89 133 127 140 127 120 8.7 356 98 38 57.2 FPR 711/712 2" 1.5" 144 58 113 145 18511.18" 6.89" 3.5" 5.25" 5" 5.5" 5" 4.72" 0.34" 14" 3.86" 1.5" 2.25" 5.67" 2.28" 4.45" 5.71" 7.28"
2 HP 2 HP 145TC 284 175 89 133 127 140 127 120 8.7 356 98 38 57.2 FPR 721/731/722 2" 1.5" 170 79 113 145 23011.18" 6.89" 3.5" 5.25" 5" 5.5" 5" 4.72" 0.34" 14" 3.86" 1.5" 2.25" 6.69" 3.11" 4.45" 5.71" 9.06"
3 HP 182TC 340 221 114 149 114 191 108 169 10.3 356 98 38 69.9 FPR 741/742 2.5" 2" 195 96 101 136 27013.39" 8.7" 4.5" 5.87" 4.5" 7.5" 4.25" 6.65" 0.41" 14" 3.86" 1.5" 2.75" 7.68" 3.78" 3.98" 5.35" 10.63"
3 HP 182TC 354 221 114 149 114 191 108 169 10.3 356 98 38 69.9 FPR 1741/1742 2.5" 2" 200 91 104 145.5 27013.94" 8.7" 4.5" 5.87" 4.5" 7.5" 4.25" 6.65" 0.41" 14" 3.86" 1.5" 2.75" 7.87" 3.58" 4.09" 5.73" 10.63"
5 HP 184TC 354 221 114 149 140 191 108 169 10.3 356 98 38 69.9 FPR 3521/3522 2.5" 2" 190 80 118 157.5 23013.94" 8.7" 4.5" 5.87" 5.5" 7.5" 4.25" 6.65" 0.41" 14" 3.86" 1.5" 2.75" 7.48" 3.15" 4.65" 6.2" 9.06"
5 HP 184TC 354 221 114 149 140 191 108 169 10.3 356 98 38 69.9 FPR 3531/3532 2.5" 2" 191 95 115.5 157.5 26013.94" 8.7" 4.5" 5.87" 5.5" 7.5" 4.25" 6.65" 0.41" 14" 3.86" 1.5" 2.75" 7.52" 3.74" 4.55" 6.2" 10.24"
7.5 HP 184TC 423 221 114 149 140 191 108 169 10.3 356 98 38 69.9 FPR 3541/3542 3" 2.5" 211 115 118 157.5 29016.65" 8.7" 4.5" 5.87" 5.5" 7.5" 4.25" 6.65" 0.41" 14" 3.86" 1.5" 2.75" 8.31" 4.53" 4.65" 6.2" 11.42"
7.5 HP 213TC 403 260 133 187 140 216 108 169 10.3 356 98 38 88.915.87" 10.25" 5.25" 7.38" 5.5" 8.5" 4.25" 6.65" 0.41" 14" 3.86" 1.5" 3.5"
10 HP 215TC 403 260 133 187 178 216 108 169 10.3 356 98 38 88.915.87" 10.25" 5.25" 7.38" 7" 8.5" 4.25" 6.65" 0.41" 14" 3.86" 1.5" 3.5"
10 HP 215TC 416 260 133 187 178 216 108 169 10.3 356 98 38 88.916.38" 10.25" 5.25" 7.38" 7" 8.5" 4.25" 6.65" 0.41" 14" 3.86" 1.5" 3.5"
15 HP 215TC 515 260 133 187 178 216 108 169 10.3 356 98 38 88.920.28" 10.25" 5.25" 7.38" 7" 8.5" 4.25" 6.65" 0.41" 14" 3.86" 1.5" 3.5"
15 HP 254TC 499 327 159 244 210 254 102 169 13.5 406 98 38 108.019.65" 12.87" 6.25" 9.63" 8.25" 10" 4" 6.65" 0.53" 16" 3.86" 1.5" 4.25"
20 HP 256TC 499 327 159 244 254 254 102 169 13.5 406 98 38 108.019.65" 12.87" 6.25" 9.63" 10" 10" 4" 6.65" 0.53" 16" 3.86" 1.5" 4.25"
20 HP 256TC 499 327 159 244 254 254 102 169 13.5 406 98 38 108.019.65" 12.87" 6.25" 9.63" 10" 10" 4" 6.65" 0.53" 16" 3.86" 1.5" 4.25"
25 HP 284TSC 588 371 178 333 241 279 121 179 13.5 445 118 45 120.723.15" 14.63" 7" 13.13" 9.5" 11" 4.75" 7.05" 0.53" 17.5" 4.63" 1.75" 4.75"
25 HP 284TC 588 371 178 333 241 279 121 179 13.5 445 118 45 120.723.15" 14.63" 7" 13.13" 9.5" 11" 4.75" 7.05" 0.53" 17.5" 4.63" 1.75" 4.75"
30 HP 286TSC 588 371 178 333 279 279 121 179 13.5 445 118 45 120.723.15" 14.63" 7" 13.13" 11" 11" 4.75" 7.05" 0.53" 17.5" 4.63" 1.75" 4.75"
30 HP 286TC 588 371 178 333 279 279 121 179 13.5 445 118 45 120.723.15" 14.63" 7" 13.13" 11" 11" 4.75" 7.05" 0.53" 17.5" 4.63" 1.75" 4.75"
40 HP 324TSC 636 419 203 359 267 318 121 179 16.7 470 118 45 133.425.04" 16.5" 8" 14.13" 10.5" 12.5" 4.75" 7.05" 0.66" 18.5" 4.63" 1.75" 5.25"
40 HP 324TC 636 419 203 359 267 318 121 179 16.7 470 118 45 133.425.04" 16.5" 8" 14.13" 10.5" 12.5" 4.75" 7.05" 0.66" 18.5" 4.63" 1.75" 5.25"
50 HP 326TSC 636 419 203 359 305 318 121 179 16.7 470 118 45 133.425.04" 16.5" 8" 14.13" 12" 12.5" 4.75" 7.05" 0.66" 18.5" 4.63" 1.75" 5.25"
50 HP 326TC 636 419 203 359 305 318 121 179 16.7 470 118 45 133.425.04" 16.5" 8" 14.13" 12" 12.5" 4.75" 7.05" 0.66" 18.5" 4.63" 1.75" 5.25"
1265000463
59
1265000203 Rev C
C
Q S
W
ZDTL
M
Ø V
Inlet
YMax. Leg
Adjustment
R X
N
A
Ø E
BP
Adjustable Legs(Optional)
Outlet
1750 RPM 3500 RPM973241995415029.9683896533.01061801191411941411122313
"29.41"95.5"9.3"17.5"70.8"57.2"5.1"68.3"41"14.0"3.6"52.4"5.7"5.4"78.5"5.4"7.8"23.210535.0614110411129.9683896533.01061801191411941411122843
"87.31"23.6"94.4"15.5"13.8"57.2"5.1"68.3"41"14.0"3.6"52.4"5.7"5.4"78.5"5.4"7.8"7.310530719110410329.9683896533.01061801191041941411122743
"87.31"96.6"96.4"15.5"60.9"57.2"5.1"68.3"41"14.0"3.6"52.4"5.7"5.5"78.5"5.4"7.8"66.316045.2027610710529.9683896533.01061801191041941411122683
"89.51"79.7"75.6"96.6"48.9"57.2"5.1"68.3"41"14.0"3.6"52.4"5.7"5.5"78.5"5.4"7.8"2.516046415.0110710529.9683896533.01061801191041941411122683
"89.51"57.5"53.4"96.6"48.9"57.2"5.1"68.3"41"14.0"3.6"52.4"5.7"5.5"78.5"5.4"7.8"2.51388 260 133 187 140 216 108 160 10.3 356 98 38 88.9
15.28" 10.25" 5.25" 7.38" 5.5" 8.5" 4.25" 6.3" 0.41" 14" 3.86" 1.5" 3.5"388 260 133 187 178 216 108 160 10.3 356 98 38 88.9
15.28" 10.25" 5.25" 7.38" 7" 8.5" 4.25" 6.3" 0.41" 14" 3.86" 1.5" 3.5"436 260 133 187 178 216 108 160 10.3 356 98 38 88.9
17.17" 10.25" 5.25" 7.38" 7" 8.5" 4.25" 6.3" 0.41" 14" 3.86" 1.5" 3.5"447 327 159 244 210 254 102 160 13.5 406 98 38 108
17.6" 12.87" 6.25" 9.63" 8.25" 10" 4" 6.3" 0.53" 16" 3.86" 1.5" 4.25"491 327 159 244 254 254 102 160 13.5 406 98 38 108
19.33" 12.87" 6.25" 9.63" 10" 10" 4" 6.3" 0.53" 16" 3.86" 1.5" 4.25"499 327 159 244 254 254 102 160 13.5 406 98 38 108
19.65" 12.87" 6.25" 9.63" 10" 10" 4" 6.3" 0.53" 16" 3.86" 1.5" 4.25"588 371 178 333 241 279 121 174 13.5 445 118 45 121
23.15" 14.63" 7" 13.13" 9.5" 11" 4.75" 6.85" 0.53" 17.5" 4.63" 1.75" 4.75"588 371 178 333 241 279 121 174 13.5 445 118 45 121
23.15" 14.63" 7" 13.13" 9.5" 11" 4.75" 6.85" 0.53" 17.5" 4.63" 1.75" 4.75"588 371 178 333 279 279 121 174 13.5 445 118 45 121
23.15" 14.63" 7" 13.13" 11" 11" 4.75" 6.85" 0.53" 17.5" 4.63" 1.75" 4.75"588 371 178 333 279 279 121 174 13.5 445 118 45 121
23.15" 14.63" 7" 13.13" 11" 11" 4.75" 6.85" 0.53" 17.5" 4.63" 1.75" 4.75"636 419 203 359 267 318 121 209 16.7 470 118 45 133
25.04" 16.5" 8" 14.13" 10.5" 12.5" 4.75" 8.23" 0.66" 18.5" 4.63" 1.75" 5.25"636 419 203 359 267 318 121 209 16.7 470 118 45 133
25.04" 16.5" 8" 14.13" 10.5" 12.5" 4.75" 8.23" 0.66" 18.5" 4.63" 1.75" 5.25"636 419 203 359 305 318 121 209 16.7 470 118 45 133
25.04" 16.5" 8" 14.13" 12" 12.5" 4.75" 8.23" 0.66" 18.5" 4.63" 1.75" 5.25"636 419 203 359 305 318 121 209 16.7 470 118 45 133
25.04" 16.5" 8" 14.13" 12" 12.5" 4.75" 8.23" 0.66" 18.5" 4.63" 1.75" 5.25"685 470 229 383 286 356 89 209 16.7 508 127 45 149
26.97" 18.5" 9" 15.06" 11.25" 14" 3.5" 8.23" 0.66" 20" 5" 1.75" 5.87"685 470 229 383 286 356 89 209 16.7 508 127 45 149
26.97" 18.5" 9" 15.06" 11.25" 14" 3.5" 8.23" 0.66" 20" 5" 1.75" 5.87"685 470 229 383 311 356 89 209 16.7 508 127 45 149
26.97" 18.5" 9" 15.06" 12.25" 14" 3.5" 8.23" 0.66" 20" 5" 1.75" 5.87"685 470 229 383 311 356 89 209 16.7 508 127 45 149
26.97" 18.5" 9" 15.06" 12.25" 14" 3.5" 8.23" 0.66" 20" 5" 1.75" 5.87"
FPR 1161 4" 4"
FPR 3551/3552 3" 2.5"
FPR 1051 4" 4"
FPR 751/752 3" 2"
FPR 3451/3452 3" 2"
B C D EPUMP MODEL INLET OUTLET AYML S T V W
3 HP 182TC
XN P Q RMOTOR HP MOTORFRAME
CT281PH 3
5 HP 184TC
CT481PH 5
7.5 HP 184TC
7.5 HP 213TC
10 HP 10 HP 215TC
15 HP 215TC
15 HP 254TC
20 HP 256TC
20 HP 256TC
25 HP 284TC
25 HP 284TSC
30 HP 286TC
30 HP 286TSC
40 HP 324TC
40 HP 324TSC
50 HP 326TC
50 HP 326TSC
75 HP 365TC
75 HP 365TSC
Z
60 HP 364TC
60 HP 364TSC
1265000463
FPR Double Flange Dimensional DrawingAll pump dimensions are in millimeters (inches). Dimensions are based on clamp fittings. Motor dimensions may vary by manufacturer.
60
A
E4X ØH
C
4" SANITARYCLAMP
232 [9.13"]
G
6" SANITARYCLAMP
239.5 [9.43"]
300.5 [11.83"]
127.8 [5.03"]
F
228.5 [9.00"]D
J
�440 [�17.32"]
K
44.4 [1.75"]MAX. ADJ.
ADJUSTABLE LEGS(OPTIONAL)
B
12650000538/19/02
FPR Double Flange Dimensional Drawing Model 4001
636 418 203 371 267 317 133 16.7 470 11725" 16.5" 8" 14.6" 10.5" 12.5" 5.2" 0.7" 18.5" 4.6"636 418 203 371 305 317 133 16.7 470 11725" 16.5" 8" 14.6" 12" 12.5" 5.2" 0.7" 18.5" 4.6"684 470 229 380 286 355 149 16.7 508 127
26.9" 18.5" 9" 15" 11.3" 14" 5.9" 0.7" 20" 5"684 470 229 380 311 355 149 16.7 508 127
26.9" 18.5" 9" 15" 12.2" 14" 5.9" 0.7" 20" 5"782 520 254 477 349 406 168 20.6 508 127
30.8" 20.5" 10" 18.8" 13.7" 16" 6.6" 0.8" 20" 5"
G ØH J KD E FMOTORFRAME A B
364TC
40 HP 324TC
CMOTORHP
12650000541/28/2008
75 HP 365TC
100 HP 405TC
50 HP 326TC
60 HP
Fristam Pumps USA2410 Parview RoadMiddleton, WI 53562-2524
Tel +1 800 841 5001Fax +1 608 831 [email protected]/usa
Part #1050000103©2014 Fristam Pumps USA
CENTRIFUGAL POSITIVE DISPLACEMENT MIXING & BLENDING