Top Banner
PermaTherm CEILING PANEL 4"WIDE 26ga. Flat Batten FSI-96 Non Skinning Butyl Caulk Clear or White Silicone Caulk Fill Void with Permatherm Foam Pack Clear or White Silicone Caulk Ceiling Channel Suspended Ceiling FSI-96 Non Skinning Butyl Caulk Bottom Chord of Open Web Truss System ( Provided by other) Metal Cover Cap 26 Gauge 16 Gauge Galvanized Channel Washer Nut 3/8” Nuts (provided by other) 3”x3” Washer 10 Ga ( Provided by other) Permatherm 4” X 36” 2 Lbs. Threaded Rod Insulation to prevent frost build up FSI-96 Non Skinning Butyl Caulk 3/8” Threaded Rod (Provided by other) 1/4” - 14 x 7/8” Tek 1 12” spacing 1/4” - 14 x 7/8” Tek 1 12” spacing DETAIL: No. 0103 Ceiling Channel Suspended Ceiling July 2012 CEILING PANEL Side View Warm Side Warm Side Cold Side This detail is commonly used for this application; however, every building project is different. You should consult your building engineer to make sure this detail will work for your particular application.
20

Ceiling Channel Suspended Ceiling - FarmTek FSI-96 Non Skinning Butyl Caulk 26 gauge Inside Angle 26 gauge inside angle to match panel skin 16 gauge inside angle wrapped with 26 gauge

May 22, 2018

Download

Documents

vuongminh
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Ceiling Channel Suspended Ceiling - FarmTek FSI-96 Non Skinning Butyl Caulk 26 gauge Inside Angle 26 gauge inside angle to match panel skin 16 gauge inside angle wrapped with 26 gauge

PermaTherm

CEILING PANEL

4"WIDE 26ga. Flat Batten

FSI-96 Non Skinning Butyl Caulk

Clear or WhiteSilicone Caulk

Fill Void with Permatherm Foam Pack

Clear or White Silicone Caulk

Ceiling Channel Suspended Ceiling

FSI-96 Non Skinning Butyl Caulk

Bottom Chord of Open Web Truss System( Provided by other)

Metal Cover Cap 26 Gauge

16 Gauge Galvanized Channel

WasherNut

3/8” Nuts(provided by other)

3”x3” Washer 10 Ga( Provided by other)

Permatherm 4” X 36” 2 Lbs. Threaded Rod Insulation to prevent frost build up

FSI-96 Non Skinning Butyl Caulk

3/8” Threaded Rod(Provided by other)

1/4” - 14 x 7/8” Tek 112” spacing

1/4” - 14 x 7/8” Tek 112” spacing

DETAIL: No. 0103Ceiling Channel Suspended Ceiling

July 2012

CEILING PANEL

Side View

Warm SideWarm Side

Cold Side

This detail is commonly used for this application; however, every buildingproject is different. You should consult your building engineer to make sure thisdetail will work for your particular application.

Page 2: Ceiling Channel Suspended Ceiling - FarmTek FSI-96 Non Skinning Butyl Caulk 26 gauge Inside Angle 26 gauge inside angle to match panel skin 16 gauge inside angle wrapped with 26 gauge

PermaTherm

FSI-96 Non Skinning Butyl Caulk

26 gauge Inside Angle

26 gauge inside angleto match panel skin

16 gauge inside angle wrapped with 26 gaugemetal to match panels

DETAIL: No. 0103Ceiling Panel Attachments

July 2012

1/4” - 14 x 7/8” Tek 112” on center

26 gauge Outside Angle

Ceiling Panel Attachments

Wal

l Pan

els

Ceiling Panels

Ceiling Panels

Warm Side

Side View

Warm Side

Cold SideCold Side

1/4”wide Field Cut thermal break

Permatherm vapor barrier tape

This detail is commonly used for this application; however, every buildingproject is different. You should consult your building engineer to make sure thisdetail will work for your particular application.

14” wide Field cutthermal break

Page 3: Ceiling Channel Suspended Ceiling - FarmTek FSI-96 Non Skinning Butyl Caulk 26 gauge Inside Angle 26 gauge inside angle to match panel skin 16 gauge inside angle wrapped with 26 gauge

PermaTherm

FSI-96 Non skinning Butyl Caulk

26 Gauge Exterior Corner FlashingTo match panel skin

Permatherm Vapor Barrier Tape

Ceiling to Wall Detail

26 gauge inside angle to match panel skin

1/4” - 14 x 7/8” Tek 112” on center

DETAIL: No. 4911Exterior Wall Detail

July 2012

1/4” - 14 X 7/8” Tek 112” on center

Side View

1/4” Field cut Thermal Break

This detail is commonly used for this application; however, every buildingproject is different. You should consult your building engineer to make sure thisdetail will work for your particular application.

Ceiling panel

Wall panel

Page 4: Ceiling Channel Suspended Ceiling - FarmTek FSI-96 Non Skinning Butyl Caulk 26 gauge Inside Angle 26 gauge inside angle to match panel skin 16 gauge inside angle wrapped with 26 gauge

PermaTherm

Permatherm Insulated Panels

Cooler Freezer - Transition Detail

Permatherm Insulated Panels

Permatherm Insulated Panels1/4” Field cutthermal break

Vapor barrier10 Mil Polyethelene

Concrete wall

DETAIL: No. 0036Cooler-Freezer Transition Detail

NOVEMBER 2008

FSI-96 Non Skinning Butyl Caulk

1/4” - 14 x 7/8” Tek 112” on Center

Top view

Cooler Side

FSI-96 Non SkinningButyl Caulking

This detail is commonly used for this application; however, every buildingproject is different. You should consult your building engineer to make sure thisdetail will work for your particular application.

Freezer Side

Page 5: Ceiling Channel Suspended Ceiling - FarmTek FSI-96 Non Skinning Butyl Caulk 26 gauge Inside Angle 26 gauge inside angle to match panel skin 16 gauge inside angle wrapped with 26 gauge

PermaTherm

Exterior Notched Wall to Ceiling

FSI-96 Non Skinning Butyl Caulk

DETAIL: No. 0029Exterior Notched Wall-Vertical Section

July 2012

26 gauge outside Corner Trim.

26 gauge Inside Corner Trimto match panel skin

1/4” - 14 x 7/8” Tek 112” on center

1/4” - 14 x 7/8” Tek 112” on center

1/4” - 14 x 7/8” Tek 112” on center

For Cooler or Freezer

Side View

Warm Side

Cold side

(Do not caulk on Cold side)

Permatherm VaporBarrier Tape

This detail is commonly used for this application; however, every buildingproject is different. You should consult your building engineer to make sure thisdetail will work for your particular application.

Page 6: Ceiling Channel Suspended Ceiling - FarmTek FSI-96 Non Skinning Butyl Caulk 26 gauge Inside Angle 26 gauge inside angle to match panel skin 16 gauge inside angle wrapped with 26 gauge

PermaTherm

Exterior Perimeter Base Flashing Detail

18 ga or 16 ga Base channel

Permatherm InsulatedWall panel

FSI-96 Non Skinning Butyl Caulk

FSI-96 Non Skinning Butyl Caulk

26 Gauge Exterior perimeterbase �ashing

1/4” - 14 x 7/8” Tek 112” on center

1/4” - 14 x 7/8” Tek 112” on center

1/4” - 14 x 7/8” Tek 112” on center

DETAIL: No. 3912Exterior Perimeter Base Flashing

July 2012

FSI-96 Non SkinningButyl Caulk

Side View

Anchor Bolt

This detail is commonly used for this application; however, every buildingproject is different. You should consult your building engineer to make sure thisdetail will work for your particular application.

Page 7: Ceiling Channel Suspended Ceiling - FarmTek FSI-96 Non Skinning Butyl Caulk 26 gauge Inside Angle 26 gauge inside angle to match panel skin 16 gauge inside angle wrapped with 26 gauge

PermaTherm

Floor Wall Intersection C

FSI-96 Non Skinning Butyl Caulk

1/4” - 14 x 7/8” Tek 112” on center

DETAIL: No. 6121Floor Wall Intersection B

July 2012

WallPanel

Perimeter Base Flashing

Vapor Barrier Flashing

Concrete Floor

Concrete Anchor

Side View

This detail is commonly used for this application; however, every buildingproject is different. You should consult your building engineer to make sure thisdetail will work for your particular application.

Silicone or UrethaneSealant

Page 8: Ceiling Channel Suspended Ceiling - FarmTek FSI-96 Non Skinning Butyl Caulk 26 gauge Inside Angle 26 gauge inside angle to match panel skin 16 gauge inside angle wrapped with 26 gauge

PermaTherm

Freezer to Cooler Juncture

FSI-96 Non SkinningButyl Caulk

PermaTherm InsulatedCooler Panel

PermaTherm InsulatedFreezer Panel

26 gauge Interior Angle to match panel skin

26 gauge Interior Trim Angle Fascia

Permatherm’s Vapor Barrier Tape

Joint Flashing

1/4” - 14 x 7/8” Tek 112” on center

DETAIL: No. 1005Freezer to Cooler Juncture

July 2012

Top View

Freezer Side

Warm Side

Cooler Side

Warm side

This detail is commonly used for this application; however, every buildingproject is different. You should consult your building engineer to make sure thisdetail will work for your particular application.

Fill gap with PermathermFoam Pack Urethane

Permatherm insulated Freezer Panel

FSI-96 Non SkinningButyl Caulk

Page 9: Ceiling Channel Suspended Ceiling - FarmTek FSI-96 Non Skinning Butyl Caulk 26 gauge Inside Angle 26 gauge inside angle to match panel skin 16 gauge inside angle wrapped with 26 gauge

PermaTherm

Girt Attachment Detail A

Offset Girt Clip

Mid Girt

10ga Steel Spline Plate

DETAIL: No. 1155Girt Attachment Detail “A”

July 2012

This detail is commonly used for this application; however, every building project is different. You should consult your building engineer to make sure thisdetail will work for your particular application.

Side View

Thermal Cut for outside wallsto prevent thermal bowing.

OutsideInside

Page 10: Ceiling Channel Suspended Ceiling - FarmTek FSI-96 Non Skinning Butyl Caulk 26 gauge Inside Angle 26 gauge inside angle to match panel skin 16 gauge inside angle wrapped with 26 gauge

PermaTherm

Girt Attachment Detail B

Offset Girt Clip

Mid Girt

10ga Steel Spline Plate

DETAIL: No. 1188Girt Attachment Detail “B”

July 2012

Side View

This detail is commonly use for this application; however, every buildingproject is different. You should consult your building engineer to make sure thisdetail will work for your particular application.

Thermal Cut for outside walls to prevent thermal bowing

Outside Inside

Page 11: Ceiling Channel Suspended Ceiling - FarmTek FSI-96 Non Skinning Butyl Caulk 26 gauge Inside Angle 26 gauge inside angle to match panel skin 16 gauge inside angle wrapped with 26 gauge

PermaTherm

Girt Attachment Detail C

10ga Steel Spline Plate

DETAIL: No. 1188Girt Attachment Detail “B”

July 2012

Side View

This detail is commonly use for this application; however, every buildingproject is different. You should consult your building engineer to make sure thisdetail will work for your particular application.

Thermal Cut for outside walls to prevent thermal bowing

Outside Inside

Gurt

Page 12: Ceiling Channel Suspended Ceiling - FarmTek FSI-96 Non Skinning Butyl Caulk 26 gauge Inside Angle 26 gauge inside angle to match panel skin 16 gauge inside angle wrapped with 26 gauge

PermaTherm

Interior Wall Base Detail to Slab

18 ga or 16 ga Base channel

Permatherm InsulatedWall panel

FSI-96 Non Skinning Butyl Caulk

FSI-96 Non Skinning Butyl Caulk

26 Gauge Exterior perimeterbase �ashing

1/4” - 14 x 7/8” Tek 112” on center

1/4” - 14 x 7/8” Tek 112” on center

1/4” - 14 x 7/8” Tek 112” on center

DETAIL: No. 3912Exterior Perimeter Base Flashing

July 2012

Silicone or Urethane sealant

Side View

Anchor Bolt

This detail is commonly used for this application; however, every buildingproject is different. You should consult your building engineer to make sure thisdetail will work for your particular application.

Silicone Sealant Silicone Sealant

Page 13: Ceiling Channel Suspended Ceiling - FarmTek FSI-96 Non Skinning Butyl Caulk 26 gauge Inside Angle 26 gauge inside angle to match panel skin 16 gauge inside angle wrapped with 26 gauge

PermaTherm

Interior Wall toExterior Wall Juncture

Cold

1/4” Field cut Thermal Break inMetal Skin

1/4” - 14 x 7/8” Tek 1 12” on center (typical)

DETAIL: No. 5554Interior Wall to Exterior Wall-Cold

July 2012

Cold Side

Cold Side

26 gauge Interior Trim Angle Fasciato match panel skin

Top View

This detail is commonly used for this application; however, every buildingproject is different. You should consult your building engineer to make sure thisdetail will work for your particular application.

1/4”-14 X 78” Tek 1

War

m s

ide

Page 14: Ceiling Channel Suspended Ceiling - FarmTek FSI-96 Non Skinning Butyl Caulk 26 gauge Inside Angle 26 gauge inside angle to match panel skin 16 gauge inside angle wrapped with 26 gauge

PermaTherm

Panel to Panel Juncture

FSI-96 NonSkinningButyl Cauk

FSI-96 NonSkinningButyl Cauk

1/4” - 14 x 7/8” Tek 112” on center

26 gauge Interior Angle to match panel skin

Permatherm Insulated Panel

Permatherm’s Insulated Metal Panel

Permatherm’sVapor BarrierTape

DETAIL: No. 1313Panel to Panel Juncture

July 2012

INSIDE Cold

OUTSIDE Warm

Expansion Trim

Top View

This detail is commonly used for this application; however, every buildingproject is different. You should consult your building engineer to make sure thisdetail will work for your particular application.

Inside Cold?

Page 15: Ceiling Channel Suspended Ceiling - FarmTek FSI-96 Non Skinning Butyl Caulk 26 gauge Inside Angle 26 gauge inside angle to match panel skin 16 gauge inside angle wrapped with 26 gauge

PermaTherm

Partition Wall to Ceiling Panel

FSI-96 Non skinning Butyl Caulk

FSI-96 Non Skinning Butyl Caulk

4” Wide 26ga Flat batten

Permatherm’s Foamed in Place Urethane

1/4” - 14 x 7/8” Tek 112” on center

DETAIL: No.3971No Title

July 2012

Ceiling PanelCeiling PanelW

all P

anel

Warm Side

Cold sideCold Side

This detail is commonly used for this application; however, every buildingproject is different. You should consult your building engineer to make sure thisdetail will work for your particular application.

Side View

Page 16: Ceiling Channel Suspended Ceiling - FarmTek FSI-96 Non Skinning Butyl Caulk 26 gauge Inside Angle 26 gauge inside angle to match panel skin 16 gauge inside angle wrapped with 26 gauge

PermaTherm

Steel Spline Suspended Ceiling( Non Walkable )

FSI-96 Non Skinning Butyl Caulk

All Thread Rod

Permatherm Ceiling Panel

10ga Steel Spline

DETAIL: No. 1008Steel Spline Suspended Ceiling

July 2012

Permatherm’s Tongue and Groove Panel System

This detail is commonly used for this application; however, every buildingproject is different. You should consult your building engineer to make sure thisdetail will work for your particular application.

Side View

Permatherm Ceiling Panel

Permatherm vaporBarrier Tape

Page 17: Ceiling Channel Suspended Ceiling - FarmTek FSI-96 Non Skinning Butyl Caulk 26 gauge Inside Angle 26 gauge inside angle to match panel skin 16 gauge inside angle wrapped with 26 gauge

PermaTherm

Ceiling Panel Ceiling Panel

T-Bar Suspended Ceiling

FSI-96 Non Skinning Butyl Cauk

FSI-96 Non Skinning Butyl Cauk

All Thread Rod

Permatherm’s 4” X 36” - 2 lbs.Polystyrene Rod Insulation(freezer only)

Permatherm’s Foam Pack UrethaneInsulation

16 galv T-Bar wrappedwith 26ga to Match Panels

Vapor Barricade (by Other)

Rod Eye

1/4” - 14 x 7/8” Tek 112” on center

DETAIL: No. 1119Rod Eye Suspended Ceiling

July 2012

Side View

This detail is commonly used for this application; however, every buildingproject is different. You should consult your building engineer to make sure thisdetail will work for your particular application.

Page 18: Ceiling Channel Suspended Ceiling - FarmTek FSI-96 Non Skinning Butyl Caulk 26 gauge Inside Angle 26 gauge inside angle to match panel skin 16 gauge inside angle wrapped with 26 gauge

PermaTherm

Thickness Change 2

FSI-96 Non Skinning Butyl Caulk

1/4” - 14 x 7/8” Tek 112” on center

DETAIL: No. 9996Thickness Change 2

July 2012

PermaTherm Insulated PanelPermatherm Insulated Panel

Permathrem Insulated Panel

Top View

This detail is commonly used for this application; however, every buildingproject is different. You should consult your building engineer to make sure thisdetail will work for your particular application.

Warm Side

Cold Side

1/4” field cut thermal Break.

Permatherm Vapor BarrierTape covering seams

Page 19: Ceiling Channel Suspended Ceiling - FarmTek FSI-96 Non Skinning Butyl Caulk 26 gauge Inside Angle 26 gauge inside angle to match panel skin 16 gauge inside angle wrapped with 26 gauge

PermaTherm

Typical Panel Detail

DETAIL: No. 8899Typical Panel Detail

July 2012

Panel w/ Shadow Lines and spline groove

Panel w/ No Shadow Lines No Spline Groove

3/8”3/4”

3/32”

3’ - 10 3/4 “Metal to Metal

3’ - 10 “Foam to Foam

33/16 “

33/16’

End Views

3’ - 10 3/4”Metal to Metal

Page 20: Ceiling Channel Suspended Ceiling - FarmTek FSI-96 Non Skinning Butyl Caulk 26 gauge Inside Angle 26 gauge inside angle to match panel skin 16 gauge inside angle wrapped with 26 gauge

PermaThermDETAIL: No. 0009

Typical Panel Joint

July 2012

Detail - Interior Joint Cold side

(no caulk on cold side)

Typical Panel Joint with Caulk

Detail - Exterior Joint

Caulk On Warm Side OnlyFSI-96 Non skinning Butyl Cauk

This detail is commonly used for this application; however, every buildingproject is different. You should consult your building engineer to make sure thisdetail will work for your particular application.

Side View

3/8” bead of caulk is required