Top Banner
CEF - Marketing - 2006 1 LV Compensation and Filtering Give Oxygen to your electrical network Varplus² capacitors Varlogic N controller Detuned Reactor LC1-D contactors Varpact modules Components Modules
9

CEF - Marketing - 2006 1 LV Compensation and Filtering Give Oxygen to your electrical network Varplus² capacitors Varlogic N controller Detuned Reactor.

Mar 26, 2015

Download

Documents

Joseph Kidd
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: CEF - Marketing - 2006 1 LV Compensation and Filtering Give Oxygen to your electrical network Varplus² capacitors Varlogic N controller Detuned Reactor.

CEF - Marketing - 2006 1

LV Compensation and Filtering Give Oxygen to your electrical network

Varplus² capacitors

Varlogic N controller

Detuned Reactor

LC1-D contactors

Varpact modules

Components

Modules

Page 2: CEF - Marketing - 2006 1 LV Compensation and Filtering Give Oxygen to your electrical network Varplus² capacitors Varlogic N controller Detuned Reactor.

CEF - Marketing - 2006 2

VARPLUS² : A fully modular offer with only one size for installation and

connection Maximum power per unit : 20 kvar at 50 Hz Installation in all positions Possibility of wiring connection at 360° 50 Hz or 60 Hz

Additional options :

IP 20/42 protection kit 2 bus bars set connection between capacitors

VARPLUS² : the range

Give Oxygen to your electrical network

Page 3: CEF - Marketing - 2006 1 LV Compensation and Filtering Give Oxygen to your electrical network Varplus² capacitors Varlogic N controller Detuned Reactor.

CEF - Marketing - 2006 3

Assembly of capacitors

VARPLUS² : the range

Give Oxygen to your electrical network

Connection with bus bars kit or you can build your

own bus bars if you prefer

Additional IP 20/42 protection kit

Page 4: CEF - Marketing - 2006 1 LV Compensation and Filtering Give Oxygen to your electrical network Varplus² capacitors Varlogic N controller Detuned Reactor.

CEF - Marketing - 2006 4

Varlogic N controllerGive Oxygen to your electrical network

Varlogic NR6 / NR12 : Analyse and inform about data of the network

Manage the reactive power to obtain the targeted cosφ

Check the proper working of the system

Easy use thanks to the auto setting

Simple reading of the main measures

Page 5: CEF - Marketing - 2006 1 LV Compensation and Filtering Give Oxygen to your electrical network Varplus² capacitors Varlogic N controller Detuned Reactor.

CEF - Marketing - 2006 5

A higher level of expertness : more than the NR6/NR12 Varlogic, the NRC12 Varlogic brings :

More measures : total current harmonic distortion THD(I), voltage and current harmonic spectrum

Answer to specific applications : 4 quadrant operation for generator application, possibility of dual cos target, medium voltage application, fixed step configuration programming

Simple interface with a graphic screen, help menu

A communicating controller Communication RS485 Modbus set as an option

Varlogic N controllerGive Oxygen to your electrical network

Page 6: CEF - Marketing - 2006 1 LV Compensation and Filtering Give Oxygen to your electrical network Varplus² capacitors Varlogic N controller Detuned Reactor.

CEF - Marketing - 2006 6

Detuned Reactors :

The detuned reactors are 3-phase inductances, designed to protect the capacitors and prevent amplification of the harmonics present on the network.

The range is going from 6 to 100 kvar, for 400/415V network voltage at 50 Hz. Three tuning orders are available (135, 190 et 215 Hz)

Safety thanks to the temperature sensor (allow the protection) Dry type very few maintenance

Detuned ReactorGive Oxygen to your electrical network

Page 7: CEF - Marketing - 2006 1 LV Compensation and Filtering Give Oxygen to your electrical network Varplus² capacitors Varlogic N controller Detuned Reactor.

CEF - Marketing - 2006 7

LC1-D contactors : The use of standard contactors may compromise the safety of

persons and installations (capacitor control is accompanied by transient operating conditions resulting from the capacitor load which, amongst other thing, generates a very high overcurrent equivalent to a short-circuit of short duration)

The LC1-D K contactors are specially designed for capacitor control.

They are fitted with a contact block allowing the current to pass on closing and with damping resistors limiting the current on energisation.

LC1 – D contactorsGive Oxygen to your electrical network

Page 8: CEF - Marketing - 2006 1 LV Compensation and Filtering Give Oxygen to your electrical network Varplus² capacitors Varlogic N controller Detuned Reactor.

CEF - Marketing - 2006 8

VARPACT : the range

Give Oxygen to your electrical network

VARPACT : A pre-wired assembly, ready to be installed in the bank. Capacitors, commutation function, protection function are

already incorporated inside VARPACT It will allow you to build your capacitors bank in a very short

time. Maximum power for 1 module : 120 kvar at 50 Hz Tested at 100% inside Schneider plant

With or without bus bars : you have the choice.

Page 9: CEF - Marketing - 2006 1 LV Compensation and Filtering Give Oxygen to your electrical network Varplus² capacitors Varlogic N controller Detuned Reactor.

CEF - Marketing - 2006 9

Installation of modules in the cubicle : Varpact with bus

bars :

Varpact without bus bars :

VARPACT : installation

Give the right specifications