CE 380. Environmental Science and Engineering. Assignment. Write on a piece of paper your name and your answer to the following question: What do environmental engineers do ?. Environmental Engineering (Section 1.1). In general: - PowerPoint PPT Presentation
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: CE 380

CE 380

Environmental Science and Engineering

1

Page 2: CE 380

Assignment

Write on a piece of paper your name and your answer to the following question:

What do environmental engineers do?

2

Page 3: CE 380

Environmental Engineering(Section 1.1)

In general:

The application of scientific and engineering principles to minimize the adverse effects of human activity on the environment and to safeguard human health and welfare

3

Page 4: CE 380

Assignment

Write on the same piece of paper your answer to the following question:

Why do you need to know this stuff?

4

Page 5: CE 380

Course Organization

Solid Waste

Hazardous and Radioactive Waste

Air

Noise Pollution

Water

WastewaterSustainability

5

Page 6: CE 380

Sustainability

Primary Chapter: 1

Supplemental Chapter: 17

6

Page 7: CE 380

Sustainability

7

Page 8: CE 380

8

Page 9: CE 380

Assignment – Due Fri.

Answer the following questions.

1.What is sustainability?

2.How does it pertain to civil engineering?

3.What are the potential pros and cons of integrating sustainability into projects/policies?

9

Page 10: CE 380

Water, Part 1

Primary Chapter: 10

Supplemental Chapters: 3, 9

10

Page 11: CE 380

WATER QUANTITY & SOURCES

Section 10.1

11

Page 12: CE 380

Water on Earth

Total Water Supply

Fresh Water Supply

Salt Water Supply

Available Fresh Water Supply

12

Page 13: CE 380

13

Page 14: CE 380

Potable Water Sources

Deep Wells

Shallow Wells

Intakes

Springs

Fresh and Saline

14

Page 15: CE 380

U.S. Water Use

15

Page 16: CE 380

U.S. Water Withdrawalsin 2005

16

Page 17: CE 380

WATER QUALITYSections 9.1 – 9.2

17

Page 18: CE 380

Exercise

Water, water everywhere but which drop can you drink?

Would you drink this?

What about it makes it seem okay or not?

18

Page 19: CE 380

REVIEW: LAWS AND REGULATIONS

19

Page 20: CE 380

The Process

Public concern and/or a recognition of link between cause and effect

Law

Regulations

20

Page 21: CE 380

Federal Government

21

Page 22: CE 380

DRINKING WATER LEGISLATION

Section 9.3

22

Page 23: CE 380

Activity - 1

Where can promulgated (final) federal laws and regulations be found?

A.Federal Register

B.Code of Federal Regulations

C.Washington Times

23

Page 24: CE 380

Activity - 2

What is the primary law regulating drinking water treatment?

A.Safe Drinking Water Act

B.Clean Water Act

C.Resource Conservation and Recovery Act

24

Page 25: CE 380

Activity - 3

What are the differences between primary and secondary standards?

A.Enforceability

B.Purpose

C.Size of plant covered

25

Page 26: CE 380

No Reported Violations

26

Page 27: CE 380

DRINKING WATER TREATMENT

Section 10.2

27

Page 28: CE 380

Drinking Water Treatment

Primary goal: Prevention of disease

Secondary goals: Good taste, odor, and color Low hardness Meet irrigation and fire protection needs

28

Page 29: CE 380

Processfor POTWs

29

Page 30: CE 380

Intake

Horizontal Centrifugal Pump

Surge Tank

Screw 30

Page 31: CE 380

General Water Treatment

Conventional

Vs.

Advanced

31

dDwtMjA3

Page 32: CE 380

SOFTENINGSection 10.2.1

32

Page 33: CE 380

Why?

Why do we soften water?

33

Page 34: CE 380

Why?

34

Page 35: CE 380

What?

What is hardness?

35

Page 36: CE 380

How?

How do we soften water?

36

Page 37: CE 380

Units

How do we get to from mg/L of ions to mg/L as CaCO3?

± = ?37

Page 38: CE 380

Example

Find total hardness (in mg/L as CaCO3) of water containing:

Ca2+ = 80 mg/L, Mg2+ = 30 mg/L,

Pb2+ = 160 mg/L, Fe 3+ = 50 mg/L

Na+ = 72 mg/L, K+ = 6 mg/L

Cl- = 100 mg/L, SO42- = 201 mg/L,

HCO3- = 165 mg/L

pH = 7.5 38

Page 39: CE 380

Units (Section 3.1.2)

ppm vs. mg/L

1 ppm is equivalent to 1 minute in:

a) 1 day

b) 2 years

c) 6 weeks

39

Page 40: CE 380

Approximations and Sig Figs(Section 3.2)

Consider:

Problem 3.26 (p. 108) Problem 3.27 (p. 108) Problem 3.29 (p. 108)

40

Page 41: CE 380

Reminder Hints for Quantitative Problems

Write down the general equation. Write down your units throughout! And use

them to come up with your final units. Be reasonable with sig figs. Ignore irrelevant data. If your answer doesn’t make sense, check. If

your check gives you the same answer, state why it doesn’t make sense.

41

Page 42: CE 380

More on Total Hardness

TH = CH + NCH

42

Page 43: CE 380

Calculating Alkalinity

CO2

CO2(aq) + H2O H+ + HCO3

-

H+ + CO3

2-

Limestone(CaCO3)

+ Ca2+

H+ + OH-

43

Page 44: CE 380

Alkalinity

44

Page 45: CE 380

Example

Find carbonate and noncarbonate hardness of water containing:

Ca2+ = 80 ppm, Mg2+ = 30 ppm,

Pb2+ = 160 mg/L, Fe 3+ = 50 mg/L

Na+ = 72 ppm, K+ = 6 ppm

Cl- = 100 ppm, SO42- = 201 ppm,

HCO3- = 165 ppm

pH = 7.5

45

Page 46: CE 380

Reminder

Calculate TH and ALK.

Determine CH.

Calculate NCH.

46

Page 47: CE 380

Example

Find the speciation of the hardness of water containing:

Ca2+ = 80 mg/L, Mg2+ = 30 mg/L,

HCO3- = 165 mg/L

pH = 7.5

47

Page 48: CE 380

Reminder

Calculate 1. CCH.

2. CNCH

3. MCH

4. MNCH Check your calculations!

48

Page 49: CE 380

Lime-Soda Softening

Hard Water

Lime and/or Soda Ash

Mixing Flocculation

Sedimentation

RecarbonationSoft Water

CO2

Sludge

Sedimentation

Sludge 49

Page 50: CE 380

Lime-Soda Softening

CO2:

CO2 + 1 Ca(OH)2 1 CaCO3 + H20CCH:

Ca(HCO3)2 + 1 Ca(OH)2 2 CaCO3+ 2 H2OCNCH:

CaSO4 + 1 Na2CO3 1 CaCO3 + Na2SO4

MCH:

Mg(HCO3)2 + 1 Ca(OH)2 1 CaCO3 + MgCO3 + 2 H2O

MgCO3 + 1 Ca(OH)2 1 Mg(OH)2 + 1 CaCO3 MNCH:

MgSO4 + 1 Na2CO3 MgCO3 + Na2SO4

MgCO3 + 1 Ca(OH)2 1 Mg(OH)2 + 1 CaCO3 50

Page 51: CE 380

Excess Lime

51

Page 52: CE 380

If we’re trying to take calcium out of the water, why do we add lime, which is a calcium-based chemical?

52

Page 53: CE 380

Example – Softening

Component mg/L CO2 8.8 as CO2

Ca2+ 70 Mg2+ 9.7 Na+ 6.9 ALK 115 as CaCO3

SO42- 96

Cl- 10.6

To solubility limits with 90% quicklime, 90% soda ash

5 MGD flowrate53

Page 54: CE 380

Example continued

Component mg/L EW meq/L CO2 8.8 as CO2 22 0.40 Ca2+ 70 20 3.50 Mg2+ 9.7 12.2 0.80 Na+ 6.9 23 0.30 ALK 115 as CaCO3 50 2.30 SO4

2- 96 48 2.00 Cl- 10.6 35.5 0.30

First: Determine TH

54

Page 55: CE 380

Ca2+

HCO3- SO4

2-

Mg2+ Na+

Cl-

CO2

0 3.5 4.3 4.6 meq/L

Example continued

Second: Determine speciation

55

Page 56: CE 380

Example continued

Component meq/L Lime Soda Ash

CO2 0.40 0.4 0 CCH 2.3 2.3 0 CNCH 1.2 0 1.2 MCH 0 0 0 MNCH 0.8 0.8 0.8 Excess 1.25 1.25

Total 4.75 2.0

Third: Determine chemical amounts (Section 3.1.3)

56

Page 57: CE 380

Assumptions

ALWAYS clearly state you are making an assumption and what that assumption is.

Examples: Assume purity = 98%

Assume generation = 4.2 lb/c/d

57

Page 58: CE 380

Example continued

Component meq/L Ca2+ 3.50 Mg2+ 0.80 Lime 4.75 Soda ash 2.0 Residual Ca2+ hardness 0.6 Residual Mg2+ hardness 0.2

Fourth: Determine sludge quantity

58

Page 59: CE 380

Split Treatment - LS Softening

Plant Influent

Lime and/or Soda Ash

Mixing Flocculation

SedimentationSoft Water

Sludge

Hard Water

To Rest of Treatment

Soft Water

Recarbonation

CO2

59

Page 60: CE 380

Selective Ca2+ Removal

If Mg2+ ≤ 40 mg/L as CaCO3

(maximum Mg hardness)

60

Page 61: CE 380

Examples

Can selective Ca2+ removal be used if all the hardness is Ca2+ and Mg2+?

1. TH = 210 mg/L as CaCO3

Ca2+ = 120 mg/L as CaCO3

2. TH = 180 mg/L as CaCO3

Ca2+ = 138 mg/L as CaCO361

Page 62: CE 380

Example Continued

TH = 180 mg/L as CaCO3

Ca2+ = 138 mg/L as CaCO3

Mg2 + = 42 mg/L as CaCO3

Calculate the amount of quicklime and soda ash required in meq/L if you (1) remove the Mg2+ and (2) leave the Mg2+ (selective Ca2+ removal). Assume ALK = 105 mg/L as CaCO3 and CO2 = 20 mg/L as CaCO3.

62

Page 63: CE 380

Other Benefits of LS Softening

Removal of other metals, arsenic, & uranium Reduction of solids, turbidity, & TOC Inactivation of bacteria & viral removal Prevention of corrosion Removal of excess fluoride

63

Page 64: CE 380

Ion Exchange Softening

64

Page 65: CE 380

Softening

Softening reaction:

Na2R + Ca(HCO3)2 CaR + 2 Na(HCO3)

Regeneration reaction

CaR + 2 NaCl Na2R + CaCl2

65

Page 66: CE 380

Example

An ion exchange water softener has 0.1 m3 of ion-exchange resin with an exchange capacity of 57 kg/m3. The occupants use 2,000 L of water per day. If the water contains 280.0 mg/L of hardness as CaCO3 and it is desired to soften it to 85 mg/L as CaCO3, how much should be bypassed? What is the time between regeneration cycles?

66

Page 67: CE 380

MIXINGSection 3.1.2

67

Page 68: CE 380

Mixing

Rapid Mix Tank

Fine Air Diffusers

Parshall Flume

68

Page 69: CE 380

Design EquationDesign Equation: Hydraulic Retention Time (Section 3.1.4)

Q

Vt

69

Page 70: CE 380

In-Class Activity

A 0.5-MGD water treatment plant will use one flash mixer designed for a 1-minute retention time. Determine the diameter of the mixer. Assume the water depth will equal 80% of the diameter.

70

Page 71: CE 380

SOLIDS REMOVALSections 10.2.2 and 10.2.3

71

Page 72: CE 380

Coagulation and Flocculation(Section 10.2.2)

72

Page 73: CE 380

Flocculator

Horizontal Shaft Type

Vertical Shaft Type

Baffled Flow Type 73

Page 74: CE 380

Solids by Size(Section 9.1.3)

Classification Diameter (mm)

Dissolved < 0.000 001

Colloidal 0.000 001 - 0.001

Suspended 0.001 - 0.1

Particulate > 0.1

74

Page 75: CE 380

Coagulation & Flocculation

Al -13 Polycation

Fe-12 Polycation75

Page 76: CE 380

Chemical Name Chemical Formula Primary Coagulant Coagulant Aid

Aluminum sulfate (Alum) Al2(SO4)3 · 14 H2O X

Ferrous sulfate FeSO4 · 7 H2O X

Ferric sulfate Fe2(SO4)3 · 9 H2O X

Ferric chloride FeCl3 · 6 H2O X

Cationic polymer Various X X

Calcium hydroxide (Lime) Ca(OH)2 X* X

Calcium oxide (Quicklime) CaO X* X

Sodium aluminate Na2Al2O4 X* X

Bentonite Clay X

Calcium carbonate CaCO3 X

Sodium silicate Na2SiO3 X

Anionic polymer Various X

Nonionic polymer Various X

76

Page 77: CE 380

Sedimentation(Section 10.2.3)

77

Page 78: CE 380

Sedimentation

Purpose: Remove solids

78

Page 79: CE 380

Sedimentation: Another View

79

Page 80: CE 380

Design Equation: Design Equation: Overflow Rate

s

o

A

QvOFR

80

Page 81: CE 380

In-Class Activity

The detention time and overflow rate for a circular settling basin were determined to be 1.5 h and 0.5 gpm/ft2, respectively. The flow rate will be 250,000 gpd. Calculate the dimensions of the basin.

81

Page 82: CE 380

In-Class Activity

A 2-MGD water treatment plant will use two rectangular sedimentation basins designed for a 3-hour total detention time. If the basins will be twice as long as wide, what will be their dimensions? What will be the OFR for each basin? Assume the water depth will equal the width.

1.Assume parallel flow.

2.Assume series flow.

82

Page 83: CE 380

FILTRATIONSection 10.2.4

83

Page 84: CE 380

Filtration

84

Page 85: CE 380

Filtration Methods

Gravity Filters

Upflow Filter

Biflow Filter

Pressure Filter 85

Page 86: CE 380

Filtration Mechanisms

86

Page 87: CE 380

Slow vs. Rapid Sand Filters

87

Page 88: CE 380

Typical Gravity Filter

Wash-water trough

Underdrain System

Sand, 0.65 m

Gravel, 0.5 m

Freeboard, 0.6 m

0.5 m

Water level during filtering

Water level during backwash

88

Page 89: CE 380

DISINFECTIONSections 9.1.5 and 10.2.5

89

Page 90: CE 380

Disinfection

90

Page 91: CE 380

Activity - 1

Why is drinking water disinfected?

91

Page 92: CE 380

Activity - 2

Who linked contaminated water to infectious disease?

A. Leonard McCoy

B. John Snow

C. Marcus Welby

92

Page 93: CE 380

Activity - 3

When was the discovery made?

A. 1600s

B. 1700s

C. 1800s

93

Page 94: CE 380

Activity - 4

In general, what is an indicator organism and why is it used?

94

Page 95: CE 380

Size Comparison10 microns

0.05 - 0.1 m

0.5 - 1.5 m

5 m

60 m

Virus

Bacteria

Red Blood Cell

Sperm95

Page 96: CE 380

Pathogen Removal/Inactivation

Where does this occur in a water treatment plant?

96

Page 97: CE 380

Activity - 5

What are the options for disinfecting water?

97

Page 98: CE 380

Activity - 6

What are characteristics of the ideal disinfectant?

98

Page 99: CE 380

Activity - 7

Adequate disinfection is a balance between which two variables?

A. Concentration and Time

B. Concentration and Flow rate

C. Flow rate and Surface area

99

Page 100: CE 380

Chlorination

chlorinator

100

Page 101: CE 380

Chlorine Demand orBreakpoint Chlorination

Chlorine added

Chl

orin

e re

sidu

al

Breakpoint

Chlorine removal by reducing compounds

Chloro-organic and chloramine formation

Chloro-organic and chloramine destruction

Formation of free chlorine

Free Residual

Combined Residual

101

Page 102: CE 380

In-Class Activity

If 1.5 mg/L of chlorine is being used and the demand is 1.2 mg/L, what is the residual?

For the same plant, if 550,000 gpd is being treated and chlorine will be bought in 1-ton containers, how long will one container last?

102

Page 103: CE 380

Ultraviolet Light

Hg Vapor

Hg Vapor

103

Page 104: CE 380

Ozonation

104

Page 105: CE 380

STORAGE AND DISTRIBUTIONSection 10.3

105

Page 106: CE 380

Storage and Distribution

106

Page 107: CE 380

SLUDGE MANAGEMENT

107

Page 108: CE 380

Sludge Management

108

Page 109: CE 380

OTHER TREATMENT OPTIONSSection 10.2.6

109

Page 110: CE 380

Lead

110

Page 111: CE 380

Membrane Treatment

111

Page 112: CE 380

112

Page 113: CE 380

113

Page 114: CE 380

Phoenix Proposed WTP

114

Page 115: CE 380

In-Class Activity

Why would an industrial plant treat incoming potable water?

Why would a resident treat incoming potable water?