Top Banner
A. Airport Name B. Circuit Identification (if applicable) C. Maximum CCR Output Current Amps Select from dropd D. Number of CCR Steps Select from dropd E. Input Voltage Select from dropd F. Frequency Select from dropd G. Series Circuit Cable Wire Length Units Feet Select from dropd H. CCR Architecture Select from dropd I. Estimated roundtrip length of L-824 series circuit wire Feet J. L-824 Wire Size AWG K. L-824 Wire Resistance ohms/1,000 Feet Note: For Tamaqua AWG 6, use 0.42 ohms/1,000 Feet L-824 LOAD VA For Tamaqua AWG 8, use 0.66 ohms/1,000 Feet 0
35

CCR Load Calculator 2014-03-13.xls

Jul 19, 2016

Download

Documents

Danielle Fowler
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: CCR Load Calculator 2014-03-13.xls

A. Airport Name

B. Circuit Identification (if applicable)

C. Maximum CCR Output Current Amps Select from dropdown or type-in

D. Number of CCR Steps Select from dropdown or type-in

E. Input Voltage Select from dropdown or type-in

F. Frequency Select from dropdown

G. Series Circuit Cable Wire Length Units Feet Select from dropdown or type-in

H. CCR Architecture Select from dropdown or type-in

I. Estimated roundtrip length of L-824 series circuit wire Feet

J. L-824 Wire Size AWG

K. L-824 Wire Resistance ohms/1,000 Feet

Note:

For Tamaqua AWG 6, use 0.42 ohms/1,000 Feet L-824 LOAD VA

For Tamaqua AWG 8, use 0.66 ohms/1,000 Feet

0

Page 2: CCR Load Calculator 2014-03-13.xls

Select from dropdown or type-in

Select from dropdown or type-in

Select from dropdown or type-in

Select from dropdown

Select from dropdown or type-in

Select from dropdown or type-in

Page 3: CCR Load Calculator 2014-03-13.xls

1. Fixture Load Calculator #1

A. Fixture Description Select from dropdown or type-in

B. Manufacturer Select from dropdown or type-in

C. Number of Light Fixtures

D. W *E.

Feet

AWG Select from dropdown or type-in

0 0 VA

F. Other Load on Isolation Transformer** VA **G. Total Isolation Transformer Load 0.0 VA

H. Isolation Transformer Used W

I. Isolation Transformer Losses 0 VA

Total CCR Load for Fixture No. 1 0 VA

2. Fixture Load Calculator #2

A. Fixture Description Select from dropdown or type-in

B. Manufacturer Select from dropdown or type-in

C. Number of Light Fixtures

D. W *E.

Feet

AWG Select from dropdown or type-in

0 0 VA

F. Other Load on Isolation Transformer** VA **G. Total Isolation Transformer Load 0.0 VA

Are long secondary wires present?

Are long secondary wires present?

1. Estimated roundtrip length of Isolation Transformer

secondary wire

2. Isolation Transformer Secondary Wire Gauge

3. Wire Resistance ohms / 1000 Feet

Note: Zero is automatically assumed if transformer is located underneath fixture.

2. Isolation Transformer Secondary Wire Gauge

3. Wire Resistance ohms / 1000 Feet

Lamp Wattage*

L-850A

* Note: Value will autofill, but you can manually enter a number

Note: Zero is automatically assumed if transformer is located underneath fixture.

1. Estimated roundtrip length of Isolation Transformer

secondary wire

Lamp Wattage*

Page 4: CCR Load Calculator 2014-03-13.xls

H. Isolation Transformer Used W

I. Isolation Transformer Losses 0 VA * Note: Value will autofill, but you can manually enter a number

Total Fixture Load No. 2 0 VA

3. Fixture Load Calculator #3

A. Fixture Description Select from dropdown or type-in

B. Manufacturer

C. Number of Light Fixtures

D. W *E.

Feet

AWG Select from dropdown or type-in

0 0 VA

F. Other Load on Isolation Transformer** VA **G. Total Isolation Transformer Load 0.0 VA

H. Isolation Transformer Used W

I. Isolation Transformer Losses 0 VA * Note: Value will autofill, but you can manually enter a number

Total Fixture Load No. 3 0 VA

4. Fixture Load Calculator #4

A. Fixture Description Select from dropdown or type-in

B. Manufacturer

C. Number of Light Fixtures

D. W *E.

Feet

3. Wire Resistance ohms / 1000 Feet

Note: Zero is automatically assumed if transformer is located underneath fixture.

1. Estimated roundtrip length of Isolation Transformer

secondary wire

Note: Zero is automatically assumed if transformer is located underneath fixture.

Lamp Wattage*

2. Isolation Transformer Secondary Wire Gauge

Are long secondary wires present?

Lamp Wattage*

Are long secondary wires present?

1. Estimated roundtrip length of Isolation Transformer

secondary wire

Page 5: CCR Load Calculator 2014-03-13.xls

AWG Select from dropdown or type-in

0 0 VA

F. Other Load on Isolation Transformer** VA **G. Total Isolation Transformer Load 0.0 VA

H. Isolation Transformer Used W

I. Isolation Transformer Losses 0 VA * Note: Value will autofill, but you can manually enter a number

Total Fixture Load No. 4 0 VA

Total Tungsten-Halogen/Incandescent Lamp Load 0 VA

2. Isolation Transformer Secondary Wire Gauge

3. Wire Resistance ohms / 1000 Feet

Page 6: CCR Load Calculator 2014-03-13.xls

Select from dropdown or type-in

Select from dropdown or type-in

Select from dropdown or type-in

Note: Any other load not listed in calculator.

Select from dropdown or type-in

Select from dropdown or type-in

Select from dropdown or type-in

Note: Any other load not listed in calculator.

* Note: Value will autofill, but you can manually enter a number

Note: If fixture has multiple lamps, enter maximum

wattage when maximum number of lamps are on.

Example: For a bi-directional L-852D (with two 30W

lamps) where both lamps can be on at the same

time, enter 60W.

Note: If fixture has multiple lamps, enter maximum

wattage when maximum number of lamps are on.

Example: For a bi-directional L-852D (with two 30W

lamps) where both lamps can be on at the same

time, enter 60W.

Page 7: CCR Load Calculator 2014-03-13.xls

* Note: Value will autofill, but you can manually enter a number

Select from dropdown or type-in

Select from dropdown or type-in

Note: Any other load not listed in calculator.

* Note: Value will autofill, but you can manually enter a number

Select from dropdown or type-in

Note: If fixture has multiple lamps, enter maximum

wattage when maximum number of lamps are on.

Example: For a bi-directional L-852D (with two 30W

lamps) where both lamps can be on at the same

time, enter 60W.

Note: If fixture has multiple lamps, enter maximum

wattage when maximum number of lamps are on.

Example: For a bi-directional L-852D (with two 30W

lamps) where both lamps can be on at the same

time, enter 60W.

Page 8: CCR Load Calculator 2014-03-13.xls

Select from dropdown or type-in

Note: Any other load not listed in calculator.

* Note: Value will autofill, but you can manually enter a number

Page 9: CCR Load Calculator 2014-03-13.xls

elevated/in-pavement Runway Guard Lights use those tabs to enter data.

1. Fixture Load Calculator #1

A. Fixture Description Select from dropdown or type-in

B. Manufacturer

C. Number of Light Fixtures

D. VA

E.

Feet

AWG

0.00 0.0 VA

F. Other Load on Isolation Transformer * VA

(Any other load not listed in calculator.)

G. Total Isolation Transformer Load 0.0 VA

H. Isolation Transformer Used W

I. Isolation Transformer Losses 0.0 VA * Note: Value will autofill, but you can manually enter a number

Total Fixture Load No. 1 0.0

2. Fixture Load Calculator #2

A. Fixture Description Select from dropdown or type-in

B. Manufacturer

C. Number of Light Fixtures

D. VA

E.

Feet

AWG

0.00 0.0 VA

F. Other Load on Isolation Transformer VA

(Any other load not listed in calculator.)

G. Total Isolation Transformer Load 0.0 VA

H. Isolation Transformer Used W

I. Isolation Transformer Losses 0.0 VA * Note: Value will autofill, but you can manually enter a number

Total Fixture Load No. 2 0.0

3. Fixture Load Calculator #3

Note: Zero is automatically assumed if transformer is located underneath fixture.

1. Estimated roundtrip length of Isolation Transformer

secondary wire

2. Isolation Transformer Secondary Wire Gauge

Are long secondary wires present?Note: Zero is automatically assumed if transformer is located underneath fixture.

1. Estimated roundtrip length of Isolation Transformer

secondary wire

2. Isolation Transformer Secondary Wire Gauge

LED fixture load

ohms / 1000 Feet

3. Wire Resistance ohms / 1000 Feet

Are long secondary wires present?

LED fixture load

3. Wire Resistance

Page 10: CCR Load Calculator 2014-03-13.xls

A. Fixture Description Select from dropdown or type-in

B. Manufacturer

C. Number of Light Fixtures

D. VA

E.

Feet

AWG

0.00 0.0 VA

F. Other Load on Isolation Transformer VA

(Any other load not listed in calculator.)

G. Total Isolation Transformer Load 0.0 VA

H. Isolation Transformer Used W

I. Isolation Transformer Losses 0.0 VA * Note: Value will autofill, but you can manually enter a number

Total Fixture Load No. 3 0.0

4. Fixture Load Calculator #4

A. Fixture Description Select from dropdown or type-in

B. Manufacturer

C. Number of Light Fixtures

D. VA

E.

Feet

AWG

0.00 0.0 VA

F. Other Load on Isolation Transformer VA

(Any other load not listed in calculator.)

G. Total Isolation Transformer Load 0.0 VA

H. Isolation Transformer Used W

I. Isolation Transformer Losses 0.0 VA * Note: Value will autofill, but you can manually enter a number

0.0

0.0

LED fixture load

LED fixture load

2. Isolation Transformer Secondary Wire Gauge

3. Wire Resistance

VA

3. Wire Resistance ohms / 1000 Feet

Are long secondary wires present?Note: Zero is automatically assumed if transformer is located underneath fixture.

1. Estimated roundtrip length of Isolation Transformer

secondary wire

Are long secondary wires present?Note: Zero is automatically assumed if transformer is located underneath fixture.

1. Estimated roundtrip length of Isolation Transformer

secondary wire

2. Isolation Transformer Secondary Wire Gauge

Total LED Fixture Load

ohms / 1000 Feet

Total Fixture Load No. 4

Page 11: CCR Load Calculator 2014-03-13.xls

* Note: Value will autofill, but you can manually enter a number

VA

* Note: Value will autofill, but you can manually enter a number

VA

Page 12: CCR Load Calculator 2014-03-13.xls

* Note: Value will autofill, but you can manually enter a number

VA

* Note: Value will autofill, but you can manually enter a number

VA

VA

Page 13: CCR Load Calculator 2014-03-13.xls

1. Sign Load No. 1 Calculator

A. Sign Manufacturer Dropdown or type-in

B. Sign Size

C. Number of Sign Modules

Note: Enter sign length for ICAO/TP312 signs.

D. Light Source Dropdown or type-in

E. Sign Power Architecture also type-in

F. Sign Style

G. Sign Transformer Used W FAA Sign Types

H. VA Legend Color Background ColorAutofill or type-in L-858Y

I. Total Number of Signs in this Configuration L-858R

L-858L

Total Sign Load No. 1 0 VA L-858B

2.

A. Sign Manufacturer Dropdown or type-in

B. Sign Size

C. Number of Sign Modules

Note: Enter sign length for ICAO/TP312 signs.

D. Light Source Dropdown or type-in

E. Sign Power Architecture also type-in

F. Sign Style

G. Sign Transformer Used W

H. VAAutofill or type-in

I. Total Number of Signs in this Configuration

Total Sign Load No. 2 0 VA

Sign Load No. 2 Calculator

Sign VA as seen on the primary of

the isolation transformer

Sign VA as seen on the primary of

the isolation transformer

Size 4 means 40 in (101.6 cm) Legend Height

Red

White

Yellow

White with Black Outline

Black

Black

Reference Data:

FAA Sign Sizes

Size 1 means 12 in. (30.5 cm) Legend Height

Size 3 means 18 in (45.7 cm) Legend Height

Size 2 means 15 in (38.1 cm) Legend Height

Type

Size 5 means 25 in (63.5 cm) Legend Height

YellowBlack

Page 14: CCR Load Calculator 2014-03-13.xls

3.

A. Sign Manufacturer Dropdown or type-in

B.

C.

Note: Enter sign length for ICAO/TP312 signs.

D. Light Source Dropdown or type-in

E. Sign Power Architecture also type-in

F. Sign Style

G. W

H. VAAutofill or type-in

I. Total Number of Signs in this Configuration

Total Sign Load No. 3 0

4. Sign Load No. 4 Calculator

A. Sign Manufacturer Dropdown or type-in

B. Sign Size

C. Number of Sign Modules

Note: Enter sign length for ICAO/TP312 signs.

D. Light Source Dropdown or type-in

E. Sign Power Architecture also type-in

F. Sign Style

G. Sign Transformer Used W

H. VAAutofill or type-in

I. Total Number of Signs in this Configuration

Total Sign Load No. 4 0 VA

5. Sign Load No. 5 Calculator

A. Sign Manufacturer Dropdown or type-in

Sign VA as seen on the primary of

the isolation transformer

VA

Sign Transformer Used

Sign VA as seen on the primary of

the isolation transformer

Sign Size

Number of Sign Modules

Sign Load No. 3 Calculator

Page 15: CCR Load Calculator 2014-03-13.xls

B. Sign Size

C. Number of Sign Modules

Note: Enter sign length for ICAO/TGP312 signs.

D. Light Source Dropdown or type-in

E. Sign Power Architecture also type-in

F. Sign Style

G. Sign Transformer Used W

H. VAAutofill or type-in

I. Total Number of Signs in this Configuration

Total Sign Load No. 5 0 VA

0 VA

Sign VA as seen on the primary of

the isolation transformer

Total Sign Load

Page 16: CCR Load Calculator 2014-03-13.xls

In-pavement RGL Load Calculator

A. L-852G

B. Select from dropdown or type-in

C. Select from dropdown or type-in

D.

E. W Select from dropdown or type-in

F.

Feet

AWG

0 VA

G. Type of Fixture Pulsing Device Used

H.

I. VA

J. 0 VA

CCR LOAD CALCULATOR | © 2009-2014 ADB Airfield Solutions | All Rights Reserved.

Note: This calculation assumes that there is no operational need to have all lights ON at the same time. If all the lights are ON, the CCR might

be overloaded in at least the high step (B5/B100). The FAA requires that RGLs pulse in all operational modes: Power-on, Normal Operation,

and Failsafe mode. Therefore, there is no operational situation in which RGL lights will be steady burning ON.

Note: This, for example, is the BRITE/AGLAS Master load, if any.

Monitoring Device Load (if present).

ohms / 1000 Feet

There also might be a CCR loading consideration if pulsing RGLs are being phased in with existing steady-burning yellow hold bars and all

lights will be steady-burning initially.

2. Isolation Transformer Secondary Wire Gauge

3. Wire Resistance

Any Other Load on CCR

Note: The load calculations assumes the fixtures alternately pulse according to FAA requirements.

Total Number of In-pavement Light Fixtures on Circuit

1. Other Pulsing Device Load plus isolation transformer loss when ON

1. Estimated roundtrip length of Isolation Transformer

secondary wire

W or VA (LED)

Fixture Description

Are long secondary wires present?

Isolation Transformer Wattage

Note: Use the Stop Bar tab if the fixture is a L-852G/S.

Fixture Manufacturer

Fixture Load

Monitored or Unmonitored?

2. Other Pulsing Device Load plus isolation transformer loss when OFF

Note: Selecting Unmonitored zeros out any load associated with the Master.

Note: Zero is automatically assumed if transformer is located underneath fixture.

Page 17: CCR Load Calculator 2014-03-13.xls

Select from dropdown or type-in

Select from dropdown or type-in

Select from dropdown or type-in

VA *Note: Enter isolation transformer load if LED.

VA *Note: Used for incandescent only. Enter 0 if LED.

Load Calculation

0 VA

0 VA

0 VA

CCR LOAD CALCULATOR | © 2009-2014 ADB Airfield Solutions | All Rights Reserved.

Note: This calculation assumes that there is no operational need to have all lights ON at the same time. If all the lights are ON, the CCR might

be overloaded in at least the high step (B5/B100). The FAA requires that RGLs pulse in all operational modes: Power-on, Normal Operation,

and Failsafe mode. Therefore, there is no operational situation in which RGL lights will be steady burning ON.

Max. CCR Load for Fixture + Pulsing

Device + Transformer

Monitoring Device Load + Other Load

Total In-pavement RGL Fixture load

There also might be a CCR loading consideration if pulsing RGLs are being phased in with existing steady-burning yellow hold bars and all

lights will be steady-burning initially.

Note: The load calculations assumes the fixtures alternately pulse according to FAA requirements.

Page 18: CCR Load Calculator 2014-03-13.xls

Elevated L-804 Runway Guard Light (RGL)

A. Fixture Description L-804Note: Use the Stop Bar tab if the L-804 is on the same circuit as the Stop Bar.

B. Fixture Manufacturer Select from dropdown or type-in

C. Fixture Load W or VA (LED) Select from dropdown or type-inNote: Enter the wattage for only one of the two lamps in the L-804 (since only one is on at a time.)

D. Type of Fixture Pulsing Device Used Select from dropdown or type-inNote: Entering PCB version inserts load for PCB only and auto zeros anything associated with BRITE / AGLAS

1. Pulsing Device Load. 0 VA

E. Are long secondary wires present?Note: Zero is automatically assumed if transformer is located underneath fixture.

Feet

2. Isolation Transformer Secondary Wire Gauge AWG

3. Wire Resistance 0 VA

F. Total Isolation Transformer Load 0 VA

G. Isolation Transformer Wattage W Select from dropdown or type-in

Isolation Transformer Losses 0 VA * Note: Value will autofill, but you can manually enter a number

H. Total Number of Elevated Light Fixtures on CircuitNote: The load calculations assumes the fixtures alternately pulse according to FAA requirements.

I. VA

J. Monitored or Unmonitored?Note: Selecting Unmonitored zeros out any load associated with the Master.

K. Monitoring Device Load (if present). 0 VA Type-inNote: This, for example, is the BRITE/AGLAS Master load, if any.

CCR LOAD CALCULATOR | © 2009-2014 ADB Airfield Solutions | All Rights Reserved.

1. Estimated roundtrip length of Isolation Transformer

secondary wire

ohms / 1000 Feet

Any Other Load on CCR

Page 19: CCR Load Calculator 2014-03-13.xls

Select from dropdown or type-in

Select from dropdown or type-inNote: Enter the wattage for only one of the two lamps in the L-804 (since only one is on at a time.)

Select from dropdown or type-inNote: Entering PCB version inserts load for PCB only and auto zeros anything associated with BRITE / AGLAS

VA *Note: Enter 0 if LED.

Feet

AWG

VA

Select from dropdown or type-in

* Note: Value will autofill, but you can manually enter a number

Note: The load calculations assumes the fixtures alternately pulse according to FAA requirements.

Load Calculation

0 VA

Monitoring Device Load + Other Load 0 VA

0 VA

CCR LOAD CALCULATOR | © 2009-2014 ADB Airfield Solutions | All Rights Reserved.

Total Elevated RGL Fixture Load

Max. CCR Load for Fixture + Pulsing Device

+ Transformer Losses

Page 20: CCR Load Calculator 2014-03-13.xls

In-pavement Stop Bar

A. Fixture Description

B. Fixture Manufacturer

C. Fixture Load

D.

1. Max. Control/Monitoring Device Load

E.

Note: Zero is automatically assumed if transformer is located underneath fixture.

1. Estimated roundtrip length of L-830 secondary wire

2. L-830 Secondary Wire Gauge

3. Wire Resistance 0

F. Isolation Transformer Wattage

G. Isolation Transformer Losses

H. Total Individual Fixture CCR Load

I. Total Number of In-pavement Stop Bar Fixtures on Circuit

Elevated Stop Bar

A. Fixture Description

B. Fixture Manufacturer

C. Fixture Load

D.

1. Max. Control/Monitoring Device Load

E.

Note: Zero is automatically assumed if transformer is located underneath fixture.

1. Estimated roundtrip length of L-830 secondary wire

2. L-830 Secondary Wire Gauge

3. Wire Resistance 0

F. Isolation Transformer Wattage

G. Isolation Transformer Losses

H. Total Individual Fixture CCR Load

I. Total Number of Elevated Stop Bar Fixtures on Circuit

Sensor Load

A. Type of Sensor Used

B. Individual Sensor + Isolation Transformer (if present) Load

C. Total number of sensors

Are long secondary wires present?

Type of Control/Monitoring Device Used

Type of Control/Monitoring Device Used

Are long secondary wires present?

ohms / 1000 Feet

ohms / 1000 Feet

Page 21: CCR Load Calculator 2014-03-13.xls

In-pavement RGL Load Calculator (L-852G Side only in RVR >1200 ft.)

A.

B.

C.

D.

Note: Zero is automatically assumed if transformer is located underneath fixture.

1. Estimated roundtrip length of L-830 secondary wire

2. L-830 Secondary Wire Gauge

3. Wire Resistance 0

E.

F. Type of Fixture Pulsing Device Used

1. Other Pulsing Device Load plus isolation transformer loss when ON

2. Other Pulsing Device Load plus isolation transformer loss when OFF

G. Total Number of In-pavement Light Fixtures on CircuitNote: The load calculations assumes the fixtures alternately pulse according to FAA requirements.

Elevated L-804 Runway Guard Light (RGL)

A. Fixture Description

Note: Use this Stop Bar tab if the L-804 is on the same circuit as the Stop Bar.

B. Fixture Manufacturer

C. Fixture LoadNote: Enter the wattage for only one of the two lamps in the L-804 (since only one is on at a time.)

D. Type of Fixture Pulsing Device UsedNote: Entering PCB version inserts load for PCB only and auto zeros anything associated with BRITE / AGLAS

1. Pulsing Device Load.

E. Are long secondary wires present?Note: Zero is automatically assumed if transformer is located underneath fixture.

1. Estimated roundtrip length of L-830 secondary wire

2. L-830 Secondary Wire Gauge

3. Wire Resistance 0

F.

G. Isolation Transformer Losses

H. Max CCR Load for Fixture + Pulsing Device + Transformer

I. Total Number of Elevated Light Fixtures on CircuitNote: The load calculations assumes the fixtures alternately pulse according to FAA requirements.

Control/Monitoring Interface Device Load

Note: This calculation assumes that there is no operational need to have all lights ON at the same time. If all the lights are ON, the CCR

might be overloaded in at least the high step (B5/B100). The FAA requires that RGLs pulse in all operational modes: Power-on, Normal

Operation, and Failsafe mode. Therefore, there is no operational situation in which RGL lights will be steady burning ON.

Isolation Transformer Wattage

Fixture Description

ohms / 1000 Feet

Isolation Transformer Wattage

Fixture Manufacturer

Fixture Load

ohms / 1000 Feet

Are long secondary wires present?

Page 22: CCR Load Calculator 2014-03-13.xls

A. Monitoring Device Load (if present).Note: This, for example, is the BRITE/AGLAS Master load, if any.

B. Any Other Load

Page 23: CCR Load Calculator 2014-03-13.xls

W or VA (LED)

VA

Feet

0 Load

W

0

0 SubTotal

0

W or VA (LED)

VA

Feet

0 Load

W

0

0 SubTotal

0

VA SubTotal

0

Note: Typing in L-852G/S enables all L-852G rows.

Page 24: CCR Load Calculator 2014-03-13.xls

In-pavement RGL Load Calculator (L-852G Side only in RVR >1200 ft.)

L-852G

W or VA (LED)

Feet

0 Load

W

VA *Note: Enter isolation transformer load if LED.

VA *Note: Used for incandescent only. Enter 0 if LED.

SubTotal

0Note: The load calculations assumes the fixtures alternately pulse according to FAA requirements.

L-804

W or VA (LED)Note: Enter the wattage for only one of the two lamps in the L-804 (since only one is on at a time.)

Note: Entering PCB version inserts load for PCB only and auto zeros anything associated with BRITE / AGLAS

0 VA *Note: Enter 0 if LED.

Feet

0 Load

W

0 VA * Note: Value will autofill, but you can manually enter a number

0 VA SubTotal

0Note: The load calculations assumes the fixtures alternately pulse according to FAA requirements.

Note: This calculation assumes that there is no operational need to have all lights ON at the same time. If all the lights are ON, the CCR

might be overloaded in at least the high step (B5/B100). The FAA requires that RGLs pulse in all operational modes: Power-on, Normal

Operation, and Failsafe mode. Therefore, there is no operational situation in which RGL lights will be steady burning ON.

Page 25: CCR Load Calculator 2014-03-13.xls

0 VA

SubTotal

VA 0

Total Stop Bar Load

0

Page 26: CCR Load Calculator 2014-03-13.xls

1. 2.

Device VA VA

Isolation Transformer Used (if any)

Isolation Transformer Losses (if any) 0

Other Losses (if any)

Quantity

Total Load 0 VA

3. 4.

Device VA VA

Isolation Transformer Used (if any)

Isolation Transformer Losses (if any) 0

Other Losses (if any)

Quantity

Total Load 0 VA

5. 6.

Device VA VA

Isolation Transformer Used (if any)

Isolation Transformer Losses (if any)

Other Losses (if any)

Quantity

Total Load 0 VA

7. 8.

Device VA VA

Isolation Transformer Used (if any)

Isolation Transformer Losses (if any) 0

Other Losses (if any)

Quantity

Total Load 0 VA

9. 10.

Device VA VA

Other Load Description (Select From Dropdown or Type-in)

Other Load Description (Select From Dropdown or Type-in)

Other Load Description (Select From Dropdown or Type-in)

Other Load Description (Select From Dropdown or Type-in)

Other Load Description (Select From Dropdown or Type-in)

Page 27: CCR Load Calculator 2014-03-13.xls

Isolation Transformer Used (if any)

Isolation Transformer Losses (if any) 0

Other Losses (if any)

Quantity

Total Load 0 VA

Total Other Loads

Page 28: CCR Load Calculator 2014-03-13.xls

Device VA VA

Isolation Transformer Used (if any)

Isolation Transformer Losses (if any) 0

Other Losses (if any)

Quantity

Total Load 0 VA

Device VA VA

Isolation Transformer Used (if any)

Isolation Transformer Losses (if any) 0

Other Losses (if any)

Quantity

Total Load 0 VA

Device VA VA

Isolation Transformer Used (if any)

Isolation Transformer Losses (if any)

Other Losses (if any)

Quantity

Total Load 0 VA

Device VA VA

Isolation Transformer Used (if any)

Isolation Transformer Losses (if any) 0

Other Losses (if any)

Quantity

Total Load 0 VA

Device VA VA

Other Load Description (Select From Dropdown or Type-in)

Other Load Description (Select From Dropdown or Type-in)

Other Load Description (Select From Dropdown or Type-in)

Other Load Description (Select From Dropdown or Type-in)

Other Load Description (Select From Dropdown or Type-in)

Page 29: CCR Load Calculator 2014-03-13.xls

Isolation Transformer Used (if any)

Isolation Transformer Losses (if any) 0

Other Losses (if any)

Quantity

Total Load 0 VA

0 VA

Page 30: CCR Load Calculator 2014-03-13.xls

CCR Load Summary

Airport Name

Circuit Identification

Maximum CCR Output Current

Number of CCR Steps

Input Voltage

Frequency

CCR Architecture

Load Description

Lamp Load 1 L-850A

Lamp Load 2

Lamp Load 3

Lamp Load 4

Total Lamp Load

LED Load 1

LED Load 2

LED Load 3

LED Load 4

Total LED Load

Sign Load 1 Sign

Sign Load 2 Sign

Sign Load 3 Sign

Sign Load 4 Sign

Sign Load 5 Sign

Total Sign Load

In-pavement RGL Fixture Load L-852G

In-pavement RGL Monitoring Device Load

Total In-pavement RGL Load

Elevated RGL Fixture Load L-804

Elevated RGL Monitoring Device Load

Total Elevated RGL Load

Stop Bar In-pavement Load

Stop Bar Elevated Fixture Load

Stop Bar Sensor Load

Stop Bar Elevated RGL Load L-852G

Stop Bar Monitoring Device Load

Total Stop Bar Load

Other Load 1

Device Description

Page 31: CCR Load Calculator 2014-03-13.xls

Other Load 2

Other Load 3

Other Load 4

Other Load 5

Other Load 6

Other Load 7

Other Load 8

Other Load 9

Other Load 10

Total Other Load

L-824 Wire Load L-824 Feet AWG

Total Calculated CCR Load

Desired Safety Factor % Type in a percentage.

CCR Load with Safety Factor 0 VA

Next Largest CCR size 0 KW

Actual CCR Safety Factor 0 %

Recommended Tap Setting 80 % Tap

(Thyristor or SCR CCR only)

Page 32: CCR Load Calculator 2014-03-13.xls

Manuf.

Isolation

Transformer Used Qty.

Individual

Device CCR

Load VA

Subtotal

Load VA

W 0 0 0

W 0 0 0

W 0 0 0

W 0 0 0

W 0 0 0

W 0 0 0

W 0 0 0

W 0 0 0

W 0

W 0

W 0

W 0

W 0

W 0 0 0

0 0 0

W 0 0 0

0

W 0 0 0

W 0 0 0

W 0 0

W 0 0 0

0

0 0 0

Device Description

Page 33: CCR Load Calculator 2014-03-13.xls

0 0 0

0 0 0

0 0 0

0 0 0

0 0 0

0 0 0

0 0 0

0 0 0

0 0 0

1 0 0

Page 34: CCR Load Calculator 2014-03-13.xls

Subtotal

Load Type

VA

0

0

0

0

0

0

Page 35: CCR Load Calculator 2014-03-13.xls

0

0