Issued 2003-05 1/1 Ref. Certif. No. NO36727/A1/M2 IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT (IECEE) CB SCHEME SYSTEME CEI D’ACCEPTATION MUTUELLE DE CERTIFICATS D’ESSAIS DES EQUIPEMENTS ELECTRIQUES (IECEE) METHODE OC CB TEST CERTIFICATE Product Produit LCD monitor Name and address of the applicant Nom et adresse du demandeur Techview International Technology Inc. 2F, No. 188 Wen Hwa 2 nd Road Kuei Shan Hsiang, Tao Yuan Shien TAIWAN Name and address of the manufacturer Nom et adresse du fabricant Techview International Technology Inc. 2F, No. 188 Wen Hwa 2 nd Road Kuei Shan Hsiang, Tao Yuan Shien TAIWAN Name and address of the factory Nom et adresse de l’usine Note: When more than one factory, please report on page 2 Note: Lorsque il y plus d'une usine, veuillez utiliser la 2 ème page Dong Guan Techview Technology Electronics Limited Yue Yuen Industrial Estate, Huang Jiang Zhen Dong Guan City, Guang Dong Province P.R. CHINA Additional Information on page 2 Ratings and principal characteristics Valeurs nominales et caractéristiques principales 1.0A 100-240V 50/60Hz Cl. I, 19" Trademark (if any) Marque de fabrique (si elle existe) acer Model / Type Ref. Ref. De type AL1923... Additional information (if necessary may also be reported on page 2) Les informations complémentaires (si nécessaire,, peuvent être indiqués sur la 2 ème page The dots "." in the model name can be 0 to 9, A to Z, or blank for marketing purpose only. Additional Information on page 2 PUBLICATION A sample of the product was tested and found to be in conformity with Un échantillon de ce produit a été essayé et a été considéré conforme à la IEC 60950-1(ed.1) As shown in the Test Report Ref. No. which forms part of this Certificate Comme indiqué dans le Rapport d’essais numéro de référence qui constitue partie de ce Certificat 78144 This certificate replaces certificate NO36727/A1/M1, due to technical modifications. This CB Test Certificate is issued by the National Certification Body Ce Certificat d’essai OC est établi par l’Organisme National de Certification P.O. BOX 73, BLINDERN N-0314 OSLO, NORWAY Date: 2006-12-18 Signature: Hanne Yndestad Certification Department
22
Embed
CBNO36726 A1 M2 - Acer Inc. · 2009. 3. 3. · Yue Yuen Industrial Estate, Huang Jiang Zhen Dong Guan City, Guang Dong Province P.R. CHINA Additional Information on page 2 Ratings
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Issued 2003-05 1/1
Ref. Certif. No.
NO36727/A1/M2
IEC SYSTEM FOR MUTUAL RECOGNITION OF TESTCERTIFICATES FOR ELECTRICAL EQUIPMENT (IECEE)CB SCHEME
SYSTEME CEI D’ACCEPTATION MUTUELLE DECERTIFICATS D’ESSAIS DES EQUIPEMENTSELECTRIQUES (IECEE) METHODE OC
CB TEST CERTIFICATE
ProductProduit
LCD monitor
Name and address of the applicantNom et adresse du demandeur
Techview International Technology Inc.2F, No. 188 Wen Hwa 2nd RoadKuei Shan Hsiang, Tao Yuan ShienTAIWAN
Name and address of the manufacturerNom et adresse du fabricant
Techview International Technology Inc.2F, No. 188 Wen Hwa 2nd RoadKuei Shan Hsiang, Tao Yuan ShienTAIWAN
Name and address of the factoryNom et adresse de l’usine
Note: When more than one factory, please report on page 2Note: Lorsque il y plus d'une usine, veuillez utiliser la 2ème page
Dong Guan Techview Technology Electronics LimitedYue Yuen Industrial Estate, Huang Jiang ZhenDong Guan City, Guang Dong ProvinceP.R. CHINA
Additional Information on page 2
Ratings and principal characteristicsValeurs nominales et caractéristiques principales 1.0A 100-240V 50/60Hz
Cl. I, 19"
Trademark (if any)Marque de fabrique (si elle existe)
acer
Model / Type Ref.Ref. De type
AL1923...
Additional information (if necessary may also be reportedon page 2)Les informations complémentaires (si nécessaire,, peuventêtre indiqués sur la 2ème page
The dots "." in the model name can be 0 to 9, A to Z, or blank formarketing purpose only.
Additional Information on page 2PUBLICATION
A sample of the product was tested and foundto be in conformity withUn échantillon de ce produit a été essayé et a étéconsidéré conforme à la
IEC 60950-1(ed.1)
As shown in the Test Report Ref. No. which forms part ofthis CertificateComme indiqué dans le Rapport d’essais numéro deréférence qui constitue partie de ce Certificat
78144
This certificate replaces certificate NO36727/A1/M1, due totechnical modifications.
This CB Test Certificate is issued by the National Certification BodyCe Certificat d’essai OC est établi par l’Organisme National de Certification
P.O. BOX 73, BLINDERNN-0314 OSLO, NORWAY
Date: 2006-12-18 Signature: Hanne YndestadCertification Department
Issued 2003-05 1/1
Ref. Certif. No.
NO41501/M1
IEC SYSTEM FOR MUTUAL RECOGNITION OF TESTCERTIFICATES FOR ELECTRICAL EQUIPMENT (IECEE)CB SCHEME
SYSTEME CEI D’ACCEPTATION MUTUELLE DECERTIFICATS D’ESSAIS DES EQUIPEMENTSELECTRIQUES (IECEE) METHODE OC
CB TEST CERTIFICATE
ProductProduit
LCD monitor
Name and address of the applicantNom et adresse du demandeur
Techview International Technology Inc.2F, No. 188 Wen Hwa 2nd RoadKuei Shan Hsiang, Tao Yuan ShienTAIWAN
Name and address of the manufacturerNom et adresse du fabricant
Techview International Technology Inc.2F, No. 188 Wen Hwa 2nd RoadKuei Shan Hsiang, Tao Yuan ShienTAIWAN
Name and address of the factoryNom et adresse de l’usine
Note: When more than one factory, please report on page 2Note: Lorsque il y plus d'une usine, veuillez utiliser la 2ème page
Dong Guan Techview Technology Electronics LimitedYue Yuen Industrial Estate, Huang Jiang ZhenDong Guan City, Guang Dong ProvinceP.R. CHINA
Additional Information on page 2
Ratings and principal characteristicsValeurs nominales et caractéristiques principales 1.0A 100-240V 50/60Hz
Cl. I, 19"
Trademark (if any)Marque de fabrique (si elle existe)
acer
Model / Type Ref.Ref. De type
X191.
Additional information (if necessary may also be reportedon page 2)Les informations complémentaires (si nécessaire,, peuventêtre indiqués sur la 2ème page
The dots "." in the model name can be 0 to 9, A to Z, or blank formarketing purpose only.
Additional Information on page 2PUBLICATION
A sample of the product was tested and foundto be in conformity withUn échantillon de ce produit a été essayé et a étéconsidéré conforme à la
IEC 60950-1(ed.1)
As shown in the Test Report Ref. No. which forms part ofthis CertificateComme indiqué dans le Rapport d’essais numéro deréférence qui constitue partie de ce Certificat
78144
This certificate replaces certificate NO41501, due to technicalmodifications.
This CB Test Certificate is issued by the National Certification BodyCe Certificat d’essai OC est établi par l’Organisme National de Certification
P.O. BOX 73, BLINDERNN-0314 OSLO, NORWAY
Date: 2006-12-18 Signature: Hanne YndestadCertification Department
- Page 1 of 18 -
This Amendment to Test Report, when bearing the Nemko name and logo is only valid when issued by a Nemko laboratory, or by a laboratory having special agreement with Nemko.
Test Report issued under the responsibility of:
www.nemko.com
Amendment to Test Report This Amendment is valid only together with the main Test Report
Report Reference No . ................... : 78144
Main Report Reference No . ............ : 57110 Tested by (printed name and signature) .......... :
Andy Lee
Approved by (printed name and signature) .......... :
Wilson Wang
Date of issue ................................... : December 18, 2006
Manufacturer ................................... : Same as applicant
Model and/or type reference ........... : 1) L9TB 2) AL1923... ; X191 . (The dots “.” in the model name can be 0 to 9, A to Z or blank for marketing purpose only.)
Serial number .................................. : Test sample without serial numbers
Name and address of production-sites (Factories): Dong Guan Techview Technology Electronics Limited Yue Yuen Industrial Estate, Huang Jiang Zhen, Dong Guan City, Guang Dong Province, P. R. China
List of attachments: 1. Photos (2 pages). 2. Power supply unit (PSU) CB test report: Hipro Electronics Co., Ltd., model HP-LC043K..., Nemko CB certificate No. NO40213, CB test report ref. No.: 71150. TDK Xiamen Co., Ltd., model XAD376ARyy, TUV CB certificate No. JPTUV-016141, CB test report ref. No.: 11008185 001. Delta Electronics, Inc., model EADP-45AF B, TUV CB certificate No. JPTUV-017020, CB test report ref. No.: 11008908 001.
Project history: Nemko Report/ Order No.:
Modification to the appliances: Changes/ Modifications in clause(s):
57110 Main test report.
72100 - Change model name from AL1923 to AL1923... - Added alternative panel source. - Change applicant and manufacture address.
1.5 and 1.7
76478 - Added alternative model designation X191 . and color of enclsoure.
1.7
76832 Issue GS certificates for models L9TB, AL1923... and X191 .
78144 - Added power board sources, panel source and mylar sheet. - Alternate internal shielding. - Alternate color (Silver and Black) of enclsoure. - DVI and Audio function will be optional.
Test case does not apply to the test object : N(/A)
Test item does meet the requirement ........ : P(ass)
Test item does not meet the requirement .. : F(ail)
Testing
Date of receipt of test item ......................... : December, 2006
Date(s) of performance of test ................... : December, 2006
General remarks
”This report is not valid as a CB Test Report unless appended by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02”.
The test result presented in this report relate only to the object(s) tested. This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory.
”(see attachment #)" refers to additional information appended to the report. "(see appended table)" refers to a table appended to the report.
Throughout this report a comma (point) is used as the decimal separator.
General product information: This Amendment shall always be enclosed with main Test Report, report/order no. 57110 and its amendments, report/order no. 72100, 76478 and 76832. The changes of concern: - Added power board sources, panel sources and mylar sheet, refer to table 1.5.1 for details. - Alternate internal shielding, refer to photos for details. - Alternate color (Silver and Black) of enclosure, refer to photos for details. - DVI and Audio function will be optional. Load condition: Full white display with max. brightness and contrast, horizontal and vertical deflection, picture provided from a signal generator. Audio function operated at maximum volume output.
- Page 4 of 18 -
www.nemko.com Report No. 78144
IEC 60950-1 / EN 60950-1
Clause Requirement – Test Result – Remark Verdict 1.5 Components P 1.5.1 General P Comply with IEC 60950 or relevant component
standard (See appended table 1.5.1.) P
1.5.2 Evaluation and testing of components Certified components are used in accordance with their ratings, certifications and they comply with applicable parts of this standard. Components not certified are used in accordance with their ratings and they comply with applicable parts of IEC 60950-1 and the relevant component standard. Components, for which no relevant IEC-standard exists, have been tested under the conditions occurring in the equipment, using applicable parts of IEC 60950-1.
P
1.6 Power interface P 1.6.2 Input current (see appended table 1.6.2) P 2.4 Limited current circuits P 2.4.1 General requirements Refer to separated PSU report. P
2.4.2 Limit values —
Frequency (Hz) ................................................... : —
Measured current (mA)....................................... : —
Measured voltage (V) ......................................... : —
2.4.3 Connection of limited current circuits to other circuits
Refer to separated PSU report. P
2.5 Limited power sources P
Inherently limited output N
Impedance limited output N Overcurrent protective device limited output Refer to separated PSU report. P
- Page 5 of 18 -
www.nemko.com Report No. 78144
IEC 60950-1 / EN 60950-1 Clause Requirement – Test Result – Remark Verdict
Regulating network limited output under normal operating and single fault condition
Refer to separated PSU report. P
Regulating network limited output under normal operating conditions and overcurrent protective device limited output under single fault condition
N
Output voltage (V), output current (A), apparent power (VA) ......................................................... :
Refer to separated PSU report. P
Current rating of overcurrent protective device (A)
Refer to separated PSU report. P
2.6 Provisions for earthing and bonding P
2.6.3.4 Resistance (Ω) of earthing conductors and their terminations, test current (A) .............................. :
From the appliance inlet to - Chassis: U = 0.3V⇒12mΩ (for 25A/1 min.) U = 0.48V⇒12mΩ (for 40A/2 min.)
P
2.9 Electrical insulation P 2.9.1 Properties of insulating materials Neither natural rubber, materials
containing asbestos nor hygroscopic materials are used as insulation. No driving belts or couplings used.
N
2.9.2 Humidity conditioning Humidity treatment performed at 40°C for 120 hrs and 25°C for 48 hrs.
—
Humidity (%) ...................................................... : 91-95% — Temperature (°C) ............................................... : 25 and 40°C —
2.9.3 Grade of insulation Insulation is considered to be functional, basic, supplementary, reinforced or double insulation.
P
2.10 Clearances, creepage distances and distances through insulation P 2.10.1 General Considered, see the following
clauses: —
2.10.2 Determination of working voltage Considered. P 2.10.3 Clearances Ref. to separated PSU report and
table 2.10.3 & 2.10.4. P
2.10.3.1 General Refer below: —
- Page 6 of 18 -
www.nemko.com Report No. 78144
IEC 60950-1 / EN 60950-1 Clause Requirement – Test Result – Remark Verdict
2.10.3.2 Clearances in primary circuit Ref. to separated PSU report and table 2.10.3 & 2.10.4
P
2.10.3.3 Clearances in secondary circuits Refer to separated PSU report. P 2.10.3.4 Measurement of transient voltage levels Measurement not relevant. N 2.10.4 Creepage distances Ref. to separated PSU report and
table 2.10.3 & 2.10.4. P
CTI tests.............................................................. : CTI rating for all material of minimum 100.
—
2.10.5 Solid insulation Refer below: P 2.10.5.1 Minimum distance through insulation Ref. to separated PSU report. P 2.10.5.2 Thin sheet material see appended table 2.10.5 P Number of layers (pcs) ....................................... : — Electric strength test — 4.2 Mechanical strength P
4.2.1 General Complies with the requirement also after tests described below are applied.
P
4.2.3 Steady force test, 30 N No hazard. Test is performed at enclosure of power supply.
P
4.5 Thermal requirements P 4.5.1 Maximum temperatures (see appended table 4.5) P Normal load condition per Annex L .................... : Rated load with continuous
operation. N
4.6 Openings in enclosures P
- Page 7 of 18 -
www.nemko.com Report No. 78144
IEC 60950-1 / EN 60950-1 Clause Requirement – Test Result – Remark Verdict 4.6.1 Top and side openings Fire enclosure (metal):
Top: A. 1.5 mm in diameter. B. Provided one opening, measures 21.9 x 1.4mm (baffled by mylar sheet, min. V-1) C. Provided one opening, measures 79.9 x 15.1 mm (secondary control board under this opening, which is supplied by L.P.S.) D. Provided one opening, measures 250 x 6.3 mm (power supply part baffled by mylar sheet; Inverter under this openings, which is supplied by L.P.S.) Left side: A. 2.4 mm in diameter. B. Provided one opening (DC/AC connector used), measures 20.3 x 7.6 mm. (which is supplied by L.P.S.) C. Provided one opening (DC/AC connector used), measures 21 x 7.6 mm. (which is supplied by L.P.S.) Right side: Provided one opening (control board connector used), measures 46.5 x 11 mm. (which is supplied by L.P.S.) Rear: A. 2.9mm in diameter. B. Max. 29.5 x 11.9 mm (located on control board, which is supplied by L.P.S.). Hazardous parts are not located within 5° vertical projection of openings.
IEC 60950-1 / EN 60950-1 Clause Requirement – Test Result – Remark Verdict
4.6.2 Bottoms of fire enclosures Fire enclosure construction is considered to comply with the requirements. Fire enclosure (metal): A. 1.5 mm in diameter and spacing of holes centre to centre is 5.5 mm which complies with requirement of table 4C. B. Provided one opening, measures 279 x 6.3 mm (power supply part baffled by mylar sheet; Inverter under these openings, which is supplied by L.P.S.)
P
Construction of the bottom.................................. : — 5 ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS P 5.1 Touch current and protective conductor current P 5.1.1 General Test conducted in accordance
with 5.1.2 to 5.1.7. —
5.1.2 Equipment under test (EUT) No interconnected equipment or multiple power sources.
N
5.1.3 Test circuit Tested for connection to IT power distribution system (also relevant for TN or TT power distribution system).
—
5.1.4 Application of measuring instrument Measuring instrument D1 is used.
—
5.1.5 Test procedure Considered — 5.1.6 Test measurements Measuring instrument D1 is
used. —
Test voltage (V) ..................................................: 264V — Measured touch current (mA) ............................: See appended table 5.1. P Max. allowed touch current (mA) .......................: 0.25 and 3.5 — Measured protective conductor current (mA) ....: N Max. allowed protective conductor current (mA) : — 5.2 Electric strength P 5.2.1 General (see appended table 5.2) P 5.2.2 Test procedure (see appended table 5.2) P
- Page 9 of 18 -
www.nemko.com Report No. 78144
IEC 60950-1 / EN 60950-1 Clause Requirement – Test Result – Remark Verdict
5.3 Abnormal operating and fault conditions P 5.3.1 Protection against overload and abnormal
operation (see appended table 5.3) P
5.3.8 Compliance criteria for abnormal operating and fault conditions
No fire or molten metal occurred and no deformation of enclosure during the tests. No reduction of clearance and creepage distances. Electric strength test is made on basic, supplementary and reinforced insulation.
P
- Page 10 of 18 -
www.nemko.com Report No. 78144
1.5.1 TABLE: list of critical components P object/part No. manufacturer/
trademark type/model technical data standard mark(s) of
conformity1)External decorative enclosure
Various HB minimum. UL94 UL
Power supply (PSU)
Delta EADP-45AF B Class I, I/P: 1500mA, 100-240V, 50-60Hz. O/P: 3.0A max. /+5.2V, 0.4A max. /+12.0V, CN201-CN204: 720Vrms/8mA max. (each of the four outputs of the DC/AC inverter)
IEC60950-1:2001
CB (by TUV, refer certificate No. JPTUV-017020)
Hipro HP-LC043K... (The dots “.” in the model name can be 0 to 9, A to Z, or blank for marketing purpose only.)
Class I, I/P: 1.1A, 100-240V, 50-60Hz. DC output: 3.0A max. /+5.0V, 0.4A max. /+12.0V, AC output: 8.0mA max., 720Vac (CN1, CN2, CN3, CN4)
IEC60950-1 (ed.1)
CB (by Nemko, refer certificate No. NO 40213)
TDK XAD376ARyy (y can be any alphanumeric character or blank)
Class I, I/P: 1.2A, 100-240V, 50-60Hz. O/P: DC 3.0A max. /+5V, 0.4A max. /+12.7V, AC 720Vac, 8.0mA (CN102-CN105)
LCD Panel LG LM190E03 19” TFT, glass is min. 0.4 mm thickness
Test in equip.
AUO M190EN04 19” TFT, glass is min. 0.4 mm thickness
Test in equip.
Mylar (between power board and bottom chassis) 1)
Various Min. V-1, 77.2mm by 140.2mm, 0.4mm thickness
UL94 UL
supplementary information: 1) an asterisk indicates a mark which assures the agreed level of surveillance 1) Only used together with power supply of Delta, type EADP-45AF B or Hipro, type HP-LC043K... or TDK, type XAD376ARyy.
- Page 11 of 18 -
www.nemko.com Report No. 78144
1.6.2 TABLE: electrical data (in normal conditions) P fuse # Irated (A) U (V) P (W) I (A) Ifuse (A) condition/status
For power supply Delta, type EADP-45AF B
F101 -- 90/50Hz 38.9 0.686 0.686 Max. normal load
F101 -- 90/60Hz 38.6 0.689 0.689 Max. normal load
F101 1 100/50Hz 38.1 0.629 0.629 Max. normal load
F101 1 100/60Hz 38.0 0.628 0.628 Max. normal load
F101 1 240/50Hz 38.7 0.299 0.299 Max. normal load
F101 1 240/60Hz 38.4 0.296 0.296 Max. normal load
F101 -- 254/50Hz 38.4 0.285 0.285 Max. normal load
F101 -- 254/60Hz 38.5 0.284 0.284 Max. normal load
F101 -- 264/50Hz 38.4 0.276 0.276 Max. normal load
F101 -- 264/60Hz 38.2 0.275 0.275 Max. normal load
For power supply Hipro, type HP-LC043K...
F1 -- 90/50Hz 37.6 0.655 0.655 Max. normal load
F1 -- 90/60Hz 37.3 0.657 0.657 Max. normal load
F1 1 100/50Hz 36.9 0.60 0.60 Max. normal load
F1 1 100/60Hz 36.9 0.604 0.604 Max. normal load
F1 1 240/50Hz 37.5 0.290 0.290 Max. normal load
F1 1 240/60Hz 37.3 0.286 0.286 Max. normal load
F1 -- 254/50Hz 37.5 0.276 0.276 Max. normal load
F1 -- 254/60Hz 37.3 0.275 0.275 Max. normal load
F1 -- 264/50Hz 37.4 0.269 0.269 Max. normal load
F1 -- 264/60Hz 37.3 0.267 0.267 Max. normal load
For power supply TDK, type XAD376ARyy
F1 -- 90/50Hz 37.8 0.666 0.666 Max. normal load
F1 -- 90/60Hz 37.7 0.665 0.665 Max. normal load
F1 1 100/50Hz 37.3 0.609 0.609 Max. normal load
F1 1 100/60Hz 37.3 0.614 0.614 Max. normal load
F1 1 240/50Hz 37.3 0.298 0.298 Max. normal load
F1 1 240/60Hz 37.1 0.296 0.296 Max. normal load
F1 -- 254/50Hz 37.1 0.285 0.285 Max. normal load
F1 -- 254/60Hz 37.0 0.284 0.284 Max. normal load
- Page 12 of 18 -
www.nemko.com Report No. 78144
fuse # Irated (A) U (V) P (W) I (A) Ifuse (A) condition/status
TABLE: clearance and creepage distance measurements P
clearance cl and creepage distance dcr at/of:
Up (V)
U r.m.s. (V)
required cl (mm)
cl (mm)
required dcr (mm)
dcr (mm)
Basic: Primary components (PSU) – case (GND)
339 240 2.0 3.4 2.5 3.4
supplementary information:
Refer to separated PSU test report. 2.10.5 TABLE: distance through insulation measurements P distance through insulation di at/of: Up
(V) test voltage
(V) required di
(mm) di
(mm)
Basic: Mylar sheet between PSU board (cover primary trace and primary component side) and case
544Vp 1834V ac 1 layer 1 layer
supplementary information:
- Page 13 of 18 -
www.nemko.com Report No. 78144
4.5 TABLE: maximum temperatures P test voltage (V) : 90V 264V — maximum temperature T of part/at:: T (°C) allowed Tmax
(°C)
For power supply Delta, type EADP-45AF B T101 coil (power & inverter) 93.1 94.6 110 T101 core (power & inverter) 88.7 90.3 110 Body of IC102 (power & inverter) 82.1 82.2 100 Body of CY101 (power & inverter) 79.8 81.0 125 FL102 coil (power & inverter) 69.3 64.5 120 FL101 coil (power & inverter) 68.0 63.5 110 Body of C101 (power & inverter) 75.3 71.6 105 PCB near BD101 (power & inverter) 75.3 70.2 130 PCB near Q101 (power & inverter) 82.6 81.9 130 PCB near CR151 (power & inverter) 96.6 97.2 130 T201 coil (power & inverter) 112.3 111.5 120 T201 core (power & inverter) 101.4 101.2 120 Body of C224 (power & inverter) 83.5 83.1 -- Inlet near L 53.5 52.6 70 PCB near U4 (main board) 73.0 73.3 105 Internal enclosure near power 55.1 55.6 -- External enclosure near power 48.7 48.4 95 Panel 56.3 55.9 95 Stand by switch 42.9 42.4 95 Ambient 40.0 40.0 --
- Page 14 of 18 -
www.nemko.com Report No. 78144
4.5 TABLE: maximum temperatures (Continued) P test voltage (V) : 90V 264V — maximum temperature T of part/at:: T (°C) allowed Tmax
(°C)
For power supply Hipro, type HP-LC043K... T1 coil (power & inverter) 98.0 99.6 110 T1 core (power & inverter) 93.3 94.7 110 Body of PC1 (power & inverter) 86.8 83.6 100 Body of CY1 (power & inverter) 83.5 82.6 85 PCB near BD1 (power & inverter) 85.9 73.4 130 NF1 coil(power & inverter) 82.7 66.3 120 Body of C1 (power & inverter) 82.4 75.9 85 PCB near Q1 (power & inverter) 90.1 81.9 130 PCB near D101 & D102 (power & inverter) 102.7 103.3 130 Inlet near L (power & inverter) 54.3 53.0 70 T31 coil (power & inverter) 119.4 119.1 120 T31 core (power & inverter) 97.8 96.7 120 PCB near IC31 (power & inverter) 81.4 80.4 130 PCB near U4 (main board) 73.2 73.7 105 Internal enclosure near power 55.1 55.3 -- External enclosure near power 48.1 48.3 95 Panel 56.6 57.1 95 Standby switch 41.3 41.0 95 Ambient 40.0 40.0 --
- Page 15 of 18 -
www.nemko.com Report No. 78144
4.5 TABLE: maximum temperatures (Continued) P test voltage (V) : 90V 264V — maximum temperature T of part/at:: T (°C) allowed Tmax
(°C)
For power supply TDK, type XAD376ARyy
T1 coil (power & inverter) 99.5 101.7 110
T1 core (power & inverter) 96.3 99.0 110
Body of IC2 (power & inverter) 89.7 90.1 100
PCB near CR1 (power & inverter) 76.9 65.2 105
L1 (power & inverter) 80.6 66.3 120
Body of C4 (power & inverter) 79.5 72.5 105
PCB near Q1 (power & inverter) 96.4 97.4 105
Inlet near L (power & inverter) 56.6 54.0 70
T101 coil (power & inverter) 111.7 110.5 120
T101 core (power & inverter) 91.4 90.2 120
PCB near IC101 (power & inverter) 100.7 99.4 105
PCB near U4 (main board) 73.6 72.8 105
Internal enclosure near power 56.8 56.1 --
External enclosure near power 49.4 48.8 95
Panel 56.7 55.8 95
Stand by switch 41.4 42.0 95
Ambient 40.0 40.0 -- supplementary information: Having a specified maximum ambient temperature of 40°C. Temperature limits include less 10K for thermocouple measurement method. Testing conducted according to 1.4.12. Tested with standard base.
- Page 16 of 18 -
www.nemko.com Report No. 78144
5.1.6 – 5.1.8
TABLE: touch current measurement P
Measured between: Measured
(mA) Limit (mA)
Comments/conditions
For power supply Delta, type EADP-45AF B
Line (Phase 1) – Protective Earthing (signal connector)