CB200 Conventional Control Panels CB200 Conventional Control Panels • Built-in detector removal indication facility • From 1 to 8 zones • 4 alarm circuits on 4-8 zone panels • Conforms to the requirements of EN 54-2 • User Friendly controls • One-man test facility • Non-latching zone feature • Class change input
CB200 Conventional Control Panels. Built-in detector removal indication facility From 1 to 8 zones 4 alarm circuits on 4-8 zone panels Conforms to the requirements of EN 54-2 User Friendly controls One-man test facility Non-latching zone feature Class change input . - PowerPoint PPT Presentation
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
CB200 Conventional Control PanelsCB200 Conventional Control Panels
• Built-in detector removal indication facility
• From 1 to 8 zones
• 4 alarm circuits on 4-8 zone panels
• Conforms to the requirements of EN 54-2
• User Friendly controls
• One-man test facility
• Non-latching zone feature
• Class change input
CB200 Conventional Control PanelsCB200 Conventional Control Panels
• Earth Fault Monitoring (4 & 8 zone only – may
be disabled)
• Fully-functional repeater available (4 & 8 zone
panels only)
• Surface or semi-flush mounting as standard
• Ample termination space
• Flame Resistant Polycarbonate enclosure
• Complies with EMC and LVD Directives
Cabinet SpecificationsCabinet Specifications
Panel dimensions are detailed in the Application
Guide.
Panel dimensions are detailed in the Application
Guide.
The removable gland plate and cable entry grommets obviate the need to drill wiring
holes in the panel on site.
The removable gland plate and cable entry grommets obviate the need to drill wiring
holes in the panel on site.
Semi-flush is available as standard because of the
construction of the CB200 enclosure.
Semi-flush is available as standard because of the
construction of the CB200 enclosure.
-
+
+
-
Mechanical AssemblyMechanical Assembly
This drawing shows the ample wiring space incorporated into
the CB200 panel design.
This drawing shows the ample wiring space incorporated into
the CB200 panel design.
Installer’s logo or brand
image may be added.
Installer’s logo or brand
image may be added.
Electronics are completely removable for convenience on site during fitting of the
back box.
Electronics are completely removable for convenience on site during fitting of the
back box.
PCB terminal support for mechanical reliability.
PCB terminal support for mechanical reliability.
There is space for two 12V 2.1AH batteries - suitable
for the 24hr standby requirements on an 8 zone
system.
There is space for two 12V 2.1AH batteries - suitable
for the 24hr standby requirements on an 8 zone
system.
User ControlsUser Controls
This is a slide-in card to add text zone
identification.
This is a slide-in card to add text zone
identification.
Press 5 to access user controls and then press 14. Controls are
then enabled.
Repeat to disable controls.
Press 5 to access user controls and then press 14. Controls are
then enabled.
Repeat to disable controls.
General system LED indications.
General system LED indications.
Zone fire and fault LEDs.
Zone fire and fault LEDs.
Typical Wiring Schematic Typical Wiring Schematic
This is a typical CB200 wiring
illustration as it appears in the
product documentation.
This is a typical CB200 wiring
illustration as it appears in the
product documentation.
Apollo S60 detectors are illustrated, but the CB200 panel supports a wide variety
of other manufacturers’ detectors - details in the Application Guide.
Apollo S60 detectors are illustrated, but the CB200 panel supports a wide variety
of other manufacturers’ detectors - details in the Application Guide.