CATERPILLAR 6060 Lighting Design Simulation Report This report is compiled to provide illustrations of product use for a particular application. It is created for evaluation purposes only. Individual machines may vary in configuration, hence affecting results. Please contact us to request a specific design for your application. Coolon recommends that all system upgrades are carried out by a qualified auto electrician.
9
Embed
CATERPILLAR - Coolon · CATERPILLAR 6060 Lighting Design Simulation Report This report is compiled to provide illustrations of product use for a particular application. It is created
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
CATERPILLAR6060
Lighting Design Simulation Report
This report is compiled to provide illustrations of product use for a particular application. It is created for evaluation purposes only. Individual machines may vary in configuration, hence affecting results. Please contact us to request a specific design for your application.
Coolon recommends that all system upgrades are carried out by a qualified auto electrician.
SIMULATIONCATERPILLAR 6060OPTION A
CATERPILLAR 6060Lighting Design Simulation Report
2This report is compiled to provide illustrations of product use for a particular application. It is created for evaluation purposes only. Individual machines may vary in configuration, hence affecting results. Please contact us to request a specific design for your application. Coolon recommends that all system upgrades are carried out by a qualified auto electrician.
LUMINAIRE SCHEDULE
OPTION A
Model No. Luminaire Optic Type QuantityCP24-L25 CP24 Flood Light L25 - Medium Optics 9
CP24-O209 CP24 Flood Light O209 - Oval Optics 1
MODEL CP24OPTIC L25ANGLE 65°
DIRECTION 0°
MODEL CP24OPTIC L25ANGLE 65°
DIRECTION 0°
MODEL CP24OPTIC L25ANGLE 45°
DIRECTION 0°
MODEL CP24OPTIC L25ANGLE 65°
DIRECTION 270°
MODEL CP24OPTIC O209ANGLE 75°
DIRECTION 0°
MODEL CP24OPTIC L25ANGLE 65°
DIRECTION 0°
MODEL CP24OPTIC L25ANGLE 45°
DIRECTION 0°
MODEL CP24OPTIC L25ANGLE 70°
DIRECTION 0°
MODEL CP24OPTIC L25ANGLE 65°
DIRECTION 160°
MODEL CP24OPTIC L25ANGLE 65°
DIRECTION 200°
MODEL CP24OPTIC L25ANGLE 65°
DIRECTION 90°
CATERPILLAR 6060
CATERPILLAR 6060Lighting Design Simulation Report
3This report is compiled to provide illustrations of product use for a particular application. It is created for evaluation purposes only. Individual machines may vary in configuration, hence affecting results. Please contact us to request a specific design for your application. Coolon recommends that all system upgrades are carried out by a qualified auto electrician.
Total LLF: 0.7
ISOLINE VIEW
OPTION A
-80
-70
-60
-50
-40
-30
-20
-10
20
30
40
50
60
70
80
0m
10
100
50
25
25
10
10
10
10
5
5
5
5
5
1
1
1
1
1
1
CATERPILLAR 6060
CATERPILLAR 6060Lighting Design Simulation Report
4This report is compiled to provide illustrations of product use for a particular application. It is created for evaluation purposes only. Individual machines may vary in configuration, hence affecting results. Please contact us to request a specific design for your application. Coolon recommends that all system upgrades are carried out by a qualified auto electrician.
OPERATOR’S VIEW
OPTION ACATERPILLAR 6060
CATERPILLAR 6060Lighting Design Simulation Report
5This report is compiled to provide illustrations of product use for a particular application. It is created for evaluation purposes only. Individual machines may vary in configuration, hence affecting results. Please contact us to request a specific design for your application. Coolon recommends that all system upgrades are carried out by a qualified auto electrician.
SIMULATION
OPTION BCATERPILLAR 6060
CATERPILLAR 6060Lighting Design Simulation Report
6This report is compiled to provide illustrations of product use for a particular application. It is created for evaluation purposes only. Individual machines may vary in configuration, hence affecting results. Please contact us to request a specific design for your application. Coolon recommends that all system upgrades are carried out by a qualified auto electrician.
LUMINAIRE SCHEDULE
OPTION B
Model No. Luminaire Optic Type QuantityCP24-L25 CP24 Flood Light L25 - Medium Optics 2
CP56-L25 CP56 Flood Light L25 - Medium Optics 7
CP56-O209 CP56 Flood Light O209 - Oval Optics 1
CATERPILLAR 6060
MODEL CP56OPTIC L25ANGLE 65°
DIRECTION 0°
MODEL CP56OPTIC L25ANGLE 65°
DIRECTION 0°
MODEL CP24OPTIC L25ANGLE 45°
DIRECTION 0°
MODEL CP56OPTIC L25ANGLE 65°
DIRECTION 270°
MODEL CP56OPTIC O209ANGLE 75°
DIRECTION 0°
MODEL CP56OPTIC L25ANGLE 65°
DIRECTION 0°
MODEL CP24OPTIC L25ANGLE 45°
DIRECTION 0°
MODEL CP56OPTIC L25ANGLE 70°
DIRECTION 0°
MODEL CP56OPTIC L25ANGLE 65°
DIRECTION 160°
MODEL CP56OPTIC L25ANGLE 65°
DIRECTION 200°
MODEL CP56OPTIC L25ANGLE 65°
DIRECTION 90°
CATERPILLAR 6060Lighting Design Simulation Report
7This report is compiled to provide illustrations of product use for a particular application. It is created for evaluation purposes only. Individual machines may vary in configuration, hence affecting results. Please contact us to request a specific design for your application. Coolon recommends that all system upgrades are carried out by a qualified auto electrician.
ISOLINE VIEW
OPTION B
Total LLF: 0.7
-80
-70
-60
-50
-40
-30
-20
-10
20
30
40
50
60
70
80
0m
10
100
100
100
50
50
50
50
50
25
25
25
25
25
25
10
10
10
10
10
10
5
5
5
5
5
5
1
1
1
1
1
1
1
1
1
CATERPILLAR 6060
CATERPILLAR 6060Lighting Design Simulation Report
8This report is compiled to provide illustrations of product use for a particular application. It is created for evaluation purposes only. Individual machines may vary in configuration, hence affecting results. Please contact us to request a specific design for your application. Coolon recommends that all system upgrades are carried out by a qualified auto electrician.
OPERATOR’S VIEW
OPTION BCATERPILLAR 6060
CATERPILLAR 6060Lighting Design Simulation Report
9This report is compiled to provide illustrations of product use for a particular application. It is created for evaluation purposes only. Individual machines may vary in configuration, hence affecting results. Please contact us to request a specific design for your application. Coolon recommends that all system upgrades are carried out by a qualified auto electrician.