NOTE C: MAXIMUM LENGTH OF DATA BUS (TERMINATION RESISTOR
NOTE M: REFER TO THE INSTALLATION GUIDE FOR ADDITION
NOTE L: 12 VOLT BATTERY SYSTEMS MUST USE THE DC/DC CONVERTER FOR THE EMS TO OPERATE PROPERLY. 24 VOLT SYSTEMS SHOULD CONNECT SWITCHED BATTERY DIRECT TO PINS
NOTE K: WHEN THE SHUTDOWN SWITCH IS CONNECTED TO BATTERY (-) THE ECM DISABLES THE FUEL INJECTION SIGNAL. THIS ACTION CAUSES THE ENGINE TO SHUTDOWN WHILE LEAVING
NOTE H: THE DEFAULT SETTING FOR THE EMS IS METRIC UNITS. IF METRIC UNITS ARE REQUIRED NO CONNECTION IS NEEDED. IF U.S. UNITS ARE REQUIRED, A PERMANENT CONNECTION TO
NOTE G: ONE MAIN EMS MODULE IS REQUIRED FOR EACH DESIRED MONITORING STATION. THE TACHOMETER AND/OR QUAD GAGE UNITS ARE OPTIONAL AND WILL NOT OPERATE WITHOUT CONNECTION TO
NOTE F: PIN 22 ON THE EMS MAIN MODULE 40 PIN CONNECTOR
+BAT.-BAT.NCCAT DATA LINK +CAT DATA LINK -NCNCATA DATA LINK -ATA DATA LINK +
+24V- BAT.
US/METRICSCROLL FORWARD
CAT DATA LINK -CAT DATA LINK +
UNUSEDWARNING LAMP
WARNINGBACKLIGHT LAMP PWR
SCROLL BACKWARD
1 2 3 4 5 6 7 8 9101112
+ BAT.- BAT. CAT DATA LINK -CAT DATA LINK + ATA DATA LINK +ATA DATA LINK -
REMOTE SHUTDOWN SW
TORQUE LIMIT SW
MAINTENANCE CLEAR SW
+BAT. (UNSWITCHED)AIR SHUTOFF SOLENOIDSOLENOID COMMONAUXILIARY TEMP SNSRCOOLANT LEVEL SNSRDIG SNSR PWR (+8V)DIG SNSR RETURNAUXILIARY PRESS. SNSRTHROTTLE POSITION SNSRANLG SNSR PWR (+5V)ANLG SNSR RETURNETHER START VALVE RELAYSTARTING AID SWMAINTENANCE CLEAR SWTORQUE LIMIT SWREMOTE SHUTDOWN SWINTERMEDIATE SPEED SWOVERSPEED VERIFY SWPTO INTERRUPT SWPTO ENABLE SWNCPTO RAMP UP SWPTO RAMP DOWN SWMAINTENANCE OVERDUE LAMPDIAGNOSTIC LAMPWARNING LAMPNC+BAT. (SWITCHED)CAT DATA LINK -CAT DATA LINK +NCNCATA DATA LINK +ATA DATA LINK -NCNCNCJ1939 SHIELDJ1939 DATA +J1939 DATA -
15A
15A
STARTING AID SW
ACB
+8VSIGNALRETURN
ABCEDFGJH
CIRCUITS WITHIN THIS AREA ARE RECOMMENDATIONS(NOTE M)
NO ADDITIONAL CONNECTIONS ARE ALLOWED TO ANY WIRES WITHOUT CATERPILLAR ENGINEERING APPROVAL UNLESS OTHERWISE SPECIFIED: ALL WIRES TO BE 18 AWG OR LARGER SAE J1128 TYPE SXL OR
EQUIVALENT. FOR TWISTED PAIR SPECIFICATION SEE SAE J1708 ELIMINATION OF ANY COMPONENTS SHOWN WILL DISABLE CERTAIN ENGINE FEATURES. CONTACT CATERPILLAR ENGINEERING WHEN
NOTE A: THE CUSTOMER CONNECTOR BRACKET GROUND STUD MUSTHAVE A DIRECT WIRE CONNECTION TO BATTERY (-). THISCONNECTION CAN BE MADE AT THE STARTER (-) TERMINAL.
NOTE B: TO AVOID LOSS OF JOB DATA STORED BY THE ECM,DISCONNECT SWITCHES SHOULD NOT INTERRUPT EITHER THE ECM
A DASHED LINE INDICATES AN OPTIONAL FEATURE NOT AVAILABLE ON ALL SYSTEMS.