Top Banner
Catalogue UV Sensor and Monitor Tel: +86-138 1039 5896 email: [email protected] web: www.haisenuv.com Provide a better life
16

Catalogue UV Sensor and Monitor - Haisen · UV water disinfection systems and UV Air purification systems. A superior long-time stability and corrosion resistance is achieved by the

Sep 18, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Catalogue UV Sensor and Monitor - Haisen · UV water disinfection systems and UV Air purification systems. A superior long-time stability and corrosion resistance is achieved by the

CatalogueUV Sensor and Monitor

Tel: +86-138 1039 5896 email: [email protected] web: www.haisenuv.com

Pro

vid

e a

be

tte

r li

fe

Page 2: Catalogue UV Sensor and Monitor - Haisen · UV water disinfection systems and UV Air purification systems. A superior long-time stability and corrosion resistance is achieved by the

Haisen Technik Co., Ltd

Provide a better life

Overview01 70001001 HS1-U Sensor with 0~5VDC output, G1/4”

02 70001002 HS1-I Sensor with 4~20mA output, G1/4”

03 70002001 HS2-U Sensor with 0~5VDC output, G1/2”

04 70002001 HS2-I Sensor with 4~20mA output, G1/2”

05 70003001 HS3-U Sensor with 0~5VDC output, G3/4”

06 70003002 HS3-I Sensor with 4~20mA output, G3/4”

07 70004001 HS4-U Sensor with 0~5VDC output

08 70004002 HS4-I Sensor with 4~20mA output

09 70005001 HS5-I Sensor with 4~20mA output for Medium Pressure Lamp

10 70005001 HS5-IZY Sensor with 4~20mA output for Medium Pressure Lamp

11 71001001 HM-1 UV monitor

12 71003001 HM-3 UV monitor

Page 3: Catalogue UV Sensor and Monitor - Haisen · UV water disinfection systems and UV Air purification systems. A superior long-time stability and corrosion resistance is achieved by the

52

Dimensions

Haisen Technik Co., Ltd

Waterproof UVC Sensor

Monitoring of relative/absolute UV-intensity

0~5V 210~280nm

Sensor Type Signal Output Value

Spectral Range

Load Impedance

HS1-U voltage output >1KΩ

www.haisenuv.com

Suitable Monitor Types

HM-1, HM-2, HM-3, HM-4, HM-5

The waterproof UVC sensor serves as robust,

long-time stable measuring head for the

precise measurement of UVC irradiances in

UV water disinfection systems and UV Air

purification systems.

A superior long-time stability and corrosion

resistance is achieved by the selection of

suitable materials.

The sensor can be directly connected to the UV-Monitor HM-1, HM-2, HM-3, HM-4 or HM-5 via a 2.5 meter long (standard) shielded cable. Thus integration into UV-lamp monitoring, adjustment and control is possible.

Spectral Sensitivity

Wavelength(nm)

Technical Data

Measuring range: 20mW/cm2

Resolution 0.01mW/cm2

Weight: 150g Operating temp.: 0~60oCStorage temp.: -10~70oCHumidity: <80%Supply voltage: 5V DCBody: Stainless steel 316LMax. pressure: 10barCable: Length 2.5m(longer on request)

Wiring Diagram

65.049.0

14.0

SW

19

G1/

4"

UV SensorBrownBlueBlack

+5V DC+5V DCVoutGND

Page 4: Catalogue UV Sensor and Monitor - Haisen · UV water disinfection systems and UV Air purification systems. A superior long-time stability and corrosion resistance is achieved by the

53

Dimensions

Haisen Technik Co., Ltd

Waterproof UVC Sensor

Monitoring of relative/absolute UV-intensity

4~20mA 210~280nm

Sensor Type Signal Output Value

Spectral Range

Load Impedance

HS1-I current output >1KΩ

www.haisenuv.com

Suitable Monitor Types

PLC or Other equipment

The waterproof UVC sensor serves as robust,

long-time stable measuring head for the

precise measurement of UVC irradiances in

UV water disinfection systems and UV Air

purification systems.

A superior long-time stability and corrosion

resistance is achieved by the selection of

suitable materials.

The sensor can be directly connected to the PLC or other equipment via a 2.5 meter long (standard) shielded cable. Thus integration into UV-lamp monitoring, adjustment and control is possible.

Spectral Sensitivity

Wavelength(nm)

Technical Data

Measuring range: 20mW/cm2

Resolution 0.01mW/cm2

Weight: 150g Operating temp.: 0~60oCStorage temp.: -10~70oCHumidity: <80%Supply voltage: 12V or 24V DCBody: Stainless steel 316LMax. pressure: 10barCable: Length 2.5m(longer on request)

Wiring Diagram

65.049.0

14.0

SW

19

G1/

4"

-

+

Blue(Signal)

Brown

UV Sensor

PLC

+24VDC

GND

4~20mA -

4~20mA +R1

250~680Ω

Page 5: Catalogue UV Sensor and Monitor - Haisen · UV water disinfection systems and UV Air purification systems. A superior long-time stability and corrosion resistance is achieved by the

54

Haisen Technik Co., Ltd

Waterproof UVC Sensor

Monitoring of relative/absolute UV-intensity

0~5V 210~280nm

Sensor Type Signal Output Value

Spectral Range

Load Impedance

HS2-U voltage output >1KΩ

www.haisenuv.com

Suitable Monitor Types

HM-1, HM-2, HM-3, HM-4, HM-5

The waterproof UVC sensor serves as robust,

long-time stable measuring head for the

precise measurement of UVC irradiances in

UV water disinfection systems and UV Air

purification systems.

A superior long-time stability and corrosion

resistance is achieved by the selection of

suitable materials.

The sensor can be directly connected to the UV-Monitor HM-1, HM-2, HM-3, HM-4 or HM-5 via a 2.5 meter long (standard) shielded cable. Thus integration into UV-lamp monitoring, adjustment and control is possible.

Spectral Sensitivity

Wavelength(nm)

Technical Data

Measuring range: 20mW/cm2

Resolution 0.01mW/cm2

Weight: 180g Operating temp.: 0~60oCStorage temp.: -10~70oCHumidity: <80%Supply voltage: 5V DCBody: Stainless steel 316LMax. pressure: 10barCable: Length 2.5m(longer on request)

Wiring Diagram

UV SensorBrownBlueBlack

+5V DC+5V DCVoutGND

Dimensions

59.042.0

13.0

Φ24

.0

G1/

2"

Page 6: Catalogue UV Sensor and Monitor - Haisen · UV water disinfection systems and UV Air purification systems. A superior long-time stability and corrosion resistance is achieved by the

55

Haisen Technik Co., Ltd

Waterproof UVC Sensor

Monitoring of relative/absolute UV-intensity

4~20mA 210~280nm

Sensor Type Signal Output Value

Spectral Range

Load Impedance

HS2-I current output >1KΩ

www.haisenuv.com

Suitable Monitor Types

PLC or Other equipment

The waterproof UVC sensor serves as robust,

long-time stable measuring head for the

precise measurement of UVC irradiances in

UV water disinfection systems and UV Air

purification systems.

A superior long-time stability and corrosion

resistance is achieved by the selection of

suitable materials.

The sensor can be directly connected to the PLC or other equipment via a 2.5 meter long (standard) shielded cable. Thus integration into UV-lamp monitoring, adjustment and control is possible.

Spectral Sensitivity

Wavelength(nm)

Technical Data

Measuring range: 20mW/cm2

Resolution 0.01mW/cm2

Weight: 180g Operating temp.: 0~60oCStorage temp.: -10~70oCHumidity: <80%Supply voltage: 12V or 24V DCBody: Stainless steel 316LMax. pressure: 10barCable: Length 2.5m(longer on request)

Wiring Diagram

-

+

Blue(Signal)

Brown

UV Sensor

Dimensions

59.042.0

13.0

Φ24

.0

G1/

2"

PLC

+24VDC

GND

4~20mA -

4~20mA +R1

250~680Ω

Page 7: Catalogue UV Sensor and Monitor - Haisen · UV water disinfection systems and UV Air purification systems. A superior long-time stability and corrosion resistance is achieved by the

56

Haisen Technik Co., Ltd

Waterproof UVC Sensor

Monitoring of relative/absolute UV-intensity

0~5V 210~280nm

Sensor Type Signal Output Value

Spectral Range

Load Impedance

HS3-U voltage output >1KΩ

www.haisenuv.com

Suitable Monitor Types

HM-1, HM-2, HM-3, HM-4, HM-5

The waterproof UVC sensor serves as robust,

long-time stable measuring head for the

precise measurement of UVC irradiances in

UV water disinfection systems and UV Air

purification systems.

A superior long-time stability and corrosion

resistance is achieved by the selection of

suitable materials.

The sensor can be directly connected to the UV-Monitor HM-1, HM-2, HM-3, HM-4 or HM-5 via a 2.5 meter long (standard) shielded cable. Thus integration into UV-lamp monitoring, adjustment and control is possible.

Spectral Sensitivity

Wavelength(nm)

Technical Data

Measuring range: 20mW/cm2

Resolution 0.01mW/cm2

Weight: 240g Operating temp.: 0~60oCStorage temp.: -10~70oCHumidity: <80%Supply voltage: 5V DCBody: Stainless steel 316LMax. pressure: 10barCable: Length 2.5m(longer on request)

Wiring Diagram

UV SensorBrownBlueBlack

+5V DC+5V DCVoutGND

Dimensions

58.0

41.5

15.0 11.5

SW

30

G3/

4"

Φ23

.0

Page 8: Catalogue UV Sensor and Monitor - Haisen · UV water disinfection systems and UV Air purification systems. A superior long-time stability and corrosion resistance is achieved by the

57

Haisen Technik Co., Ltd

Waterproof UVC Sensor

Monitoring of relative/absolute UV-intensity

4~20mA 210~280nm

Sensor Type Signal Output Value

Spectral Range

Load Impedance

HS3-I current output >1KΩ

www.haisenuv.com

Suitable Monitor Types

PLC or Other equipment

The waterproof UVC sensor serves as robust,

long-time stable measuring head for the

precise measurement of UVC irradiances in

UV water disinfection systems and UV Air

purification systems.

A superior long-time stability and corrosion

resistance is achieved by the selection of

suitable materials.

The sensor can be directly connected to the PLC or other quipment via a 2.5 meter long (standard) shielded cable. Thus integration into UV-lamp monitoring, adjustment and control is possible.

Spectral Sensitivity

Wavelength(nm)

Technical Data

Measuring range: 20mW/cm2

Resolution 0.01mW/cm2

Weight: 240g Operating temp.: 0~60oCStorage temp.: -10~70oCHumidity: <80%Supply voltage: 12V or 24V DCBody: Stainless steel 316LMax. pressure: 10barCable: Length 2.5m(longer on request)

Wiring Diagram

Dimensions

58.0

41.5

15.0 11.5

SW

30

G3/

4"

Φ23

.0

-

+

Blue(Signal)

Brown

UV Sensor

PLC

+24VDC

GND

4~20mA -

4~20mA +R1

250~680Ω

Page 9: Catalogue UV Sensor and Monitor - Haisen · UV water disinfection systems and UV Air purification systems. A superior long-time stability and corrosion resistance is achieved by the

58

Haisen Technik Co., Ltd

Normal UVC Sensor

Monitoring of relative/absolute UV-intensity

0~5V 210~280nm

Sensor Type Signal Output Value

Spectral Range

Load Impedance

HS4-U voltage output >1KΩ

www.haisenuv.com

Suitable Monitor Types

HM-1, HM-2, HM-3, HM-4, HM-5

The UVC sensor serves as robust, long-time

stable measuring head for the precise

measurement of UVC irradiances in UV water

disinfection systems and UV Air purification

systems.

A superior long-time stability and corrosion

resistance is achieved by the selection of

suitable materials.

The sensor can be directly connected to the UV-Monitor HM-1, HM-2, HM-3, HM-4 or HM-5 via a 2.5 meter long (standard) shielded cable. Thus integration into UV-lamp monitoring, adjustment and control is possible.

Spectral Sensitivity

Wavelength(nm)

Technical Data

Measuring range: 20W/cm2

Resolution 0.01mW/cm2

Weight: 240g Operating temp.: 0~60oCStorage temp.: -10~70oCHumidity: <80%Supply voltage: 5V DCBody: Stainless steel 316LCable: Length 2.5m(longer on request)

Wiring Diagram

Dimensions

?16

.5

214.0

175.0

18.6

12.6

GNDVout

+5V DC+5V DC

WhiteBlackRed

UV Sensor

Page 10: Catalogue UV Sensor and Monitor - Haisen · UV water disinfection systems and UV Air purification systems. A superior long-time stability and corrosion resistance is achieved by the

59

Haisen Technik Co., Ltd

Normal UVC Sensor

Monitoring of relative/absolute UV-intensity

4~20mA 210~280nm

Sensor Type Signal Output Value

Spectral Range

Load Impedance

HS4-I Current output >1KΩ

www.haisenuv.com

Suitable Monitor Types

PLC or other equipment

The UVC sensor serves as robust, long-time

stable measuring head for the precise

measurement of UVC irradiances in UV water

disinfection systems and UV Air purification

systems.

A superior long-time stability and corrosion

resistance is achieved by the selection of

suitable materials.

The sensor can be directly connected to the UV-Monitor PLC or other equipment via a 2.5 meter long (standard) shielded cable. Thus integration into UV-lamp monitoring, adjustment and control is possible.

Spectral Sensitivity

Wavelength(nm)

Technical Data

Measuring range: 20mW/cm2

Resolution 0.01mW/cm2

Weight: 240g Operating temp.: 0~60oCStorage temp.: -10~70oCHumidity: <80%Supply voltage: 12V or 24V DCBody: Stainless steel 316LCable: Length 2.5m(longer on request)

Wiring Diagram

Dimensions

?16

.5

214.0

175.0

18.6

12.6

Red

Black(signal)

+

-UV Sensor

PLC

+24VDC

GND

4~20mA -

4~20mA +R1

250~680Ω

Page 11: Catalogue UV Sensor and Monitor - Haisen · UV water disinfection systems and UV Air purification systems. A superior long-time stability and corrosion resistance is achieved by the

60

Haisen Technik Co., Ltd

UV Monitor for UVC Sensor with Relay Contacts

and Status Indication by Digital Tube

UV Monitor HM-1

www.haisenuv.com

Monitoring of relative UV-intensity (depending

on sensor type) (%).

The mains-driven panel meter HM-1 serves with

the respective sensors for a continuous

radio-metric control of lamps, especially UV

radiators. Different UV and visible spectral

ranges can be controlled with the corresponding

sensors.

Technical Data

Measuring range: 0~19999μW/cm2

Resolution +/- 0.2% Weight: 320g Operating temp.: 0~50oCStorage temp.: -10~70oCHumidity: <80%Supply voltage: 85~265VAC 50/60Hz Dimensions: 48X48X84mmOpen Dimensions: 45X45mmSensor signal input: 0~5V DCRelay contact for alarm: 1 X time-over

and 1 X UV low contact

Wiring Diagram

Dimensions

SET

48

48

84

76

HM-1

Time-over contact

8

6

7 UV Low contact

9

10

3

1

2

4

5

Power supply 85~265V AC

Sensor signal input

+5V DC

GND

Page 12: Catalogue UV Sensor and Monitor - Haisen · UV water disinfection systems and UV Air purification systems. A superior long-time stability and corrosion resistance is achieved by the

62

Haisen Technik Co., Ltd

UV Monitor for UVC Sensor with Relay Contacts

and Status Indication by 16X2 LCD

UV Monitor HM-3

www.haisenuv.com

Monitoring of relative and absolute UV-intensity

(depending on sensor type) .

The mains-driven panel meter HM-3 serves with

the respective sensors for a continuous

radio-metric control of lamps, especially UV

radiators. Different UV and visible spectral

ranges can be controlled with the corresponding

sensors.

Technical Data

Measuring range: 0~20000μW/cm2

Resolution +/- 0.2% Weight: 420g Operating temp.: 0~50oCStorage temp.: -10~70oCHumidity: <80%Supply voltage: 85~265VAC 50/60Hz Dimensions: 96X48X74mmOpen Dimensions: 92X45mmSensor signal input: 0~5V DCSignal Output: 1X4~20mA and 1X1~5V DCRelay contact for alarm: time-over and UV

low contact

Wiring Diagram

Dimensions

HM-3

13

11

12

14

15

3

1

2

4

5

Power supply 85~265V AC

Sensor signal input

+5V DC

GND

8

6

7

9

10

18

16

17

19

20

1~5V DC_

+

4~20mA

96 74

66

_

+

48

Page 13: Catalogue UV Sensor and Monitor - Haisen · UV water disinfection systems and UV Air purification systems. A superior long-time stability and corrosion resistance is achieved by the

63

Haisen Technik Co., Ltd

Waterproof UVC Sensor

Monitoring of relative/absolute UV-intensity

4~20mA 210~280nm

Sensor Type Signal Output Value

Spectral Range

Load Impedance

HS5-I current output >1KΩ

www.haisenuv.com

Suitable Monitor Types

PLC or Other equipment

The waterproof UVC sensor serves as robust,

long-time stable measuring head for the

precise measurement of UVC irradiances in

UV water disinfection systems and UV Air

purification systems.

A superior long-time stability and corrosion

resistance is achieved by the selection of

suitable materials.

The sensor can be directly connected to the PLC or other quipment via a 2.5 meter long (standard) shielded cable. Thus integration into UV-lamp monitoring, adjustment and control is possible.

Spectral Sensitivity

Wavelength(nm)

Technical Data

Measuring range: 250mW/cm2

Options measuring range:500 or 1000mW/cm2

Resolution 1mW/cm2

Weight: 240g Operating temp.: 0~60oCStorage temp.: -10~70oCHumidity: <80%Supply voltage: 12V or 24V DCBody: Stainless steel 316LMax. pressure: 10barCable: Length 2.5m(longer on request)

Wiring Diagram

Dimensions

-

+

Blue(Signal)

Brown

UV Sensor

PLC

+24VDC

GND

4~20mA -

4~20mA +R1

250~680Ω

92.0

50.0 17.0

G3/

4"

Page 14: Catalogue UV Sensor and Monitor - Haisen · UV water disinfection systems and UV Air purification systems. A superior long-time stability and corrosion resistance is achieved by the

64

Haisen Technik Co., Ltd

Waterproof UVC Sensor

Monitoring of relative/absolute UV-intensity

4~20mA 210~280nm

Sensor Type Signal Output Value

Spectral Range

Load Impedance

HS5-IZY current output >1KΩ

www.haisenuv.com

Suitable Monitor Types

PLC or Other equipment

The waterproof UVC sensor serves as robust,

long-time stable measuring head for the

precise measurement of UVC irradiances in

UV water disinfection systems and UV Air

purification systems.

A superior long-time stability and corrosion

resistance is achieved by the selection of

suitable materials.

The sensor can be directly connected to the PLC or other quipment via the connector. Thus integration into UV-lamp monitoring, adjustment and control is possible.

Spectral Sensitivity

Wavelength(nm)

Technical Data

Measuring range: 500mW/cm2

Options measuring range:250 or 1000mW/cm2

Resolution 1mW/cm2

Weight: 420g Operating temp.: 0~60oCStorage temp.: -10~70oCHumidity: <80%Supply voltage: 12V or 24V DCBody: Stainless steel 316LMax. pressure: 10bar

Wiring Diagram

Dimensions

UV Sensor

PLC

+24VDC

GND

4~20mA -

4~20mA +R1

250~680Ω

1 2

3

+ -

4~20mA 12/24VDC

12

3

+

-

Page 15: Catalogue UV Sensor and Monitor - Haisen · UV water disinfection systems and UV Air purification systems. A superior long-time stability and corrosion resistance is achieved by the

12

Haisen Technik Co., Ltd

UV Monitor for UVC Sensor with Relay Contacts

and Status Indication by Digital Tube

Manual of HM-1 and HS1,2,3-U

www.haisenuv.com

C-01: setting the low limit relative value for 50% or other value

0~99%C-02: setting the operate time of alarm

0~9999 hoursE-01: low limit relative valueE-02: more than the operate

Wiring Diagram

+5V DC Brown

UV SensorVout Blue

GND Black

Parameter Specification

1. Press + into the setting interface.

Parameter Setting

2. Press , you can choose the parameter which you want to setting(C-01 and C-02).

3. Press , you can choose the digit of C-01 and C-02. Then press and confirm the value you need.

4. Press button, until stop flashing.

6. Press + button and back to the operate interface.

5. Press button and rerurn to the 2 step.

HM-1

Time-over contact

8

6

7 UV Low contact

9

10

3

1

2

4

5

Power supply 85~265V AC

Sensor signal input

+5V DC

GND

Press more than 5 seconds for the default value Setting:

C-01: 50%C-02: 8000 hours

Page 16: Catalogue UV Sensor and Monitor - Haisen · UV water disinfection systems and UV Air purification systems. A superior long-time stability and corrosion resistance is achieved by the

13

Haisen Technik Co., Ltd

UV Monitor for UVC Sensor with Relay Contacts

and Status Indication by 16X2 LCD

Manual of HM-3 and HS1,2,3-U

www.haisenuv.com

AV: absolute value of uv instensityRV: relative value of uv instensity AT: timerC-00: setting the relative value 100%C-01: setting the low limit relative

value for 50% or other valueC-02: setting the operate time of alarm

Monitor HM-3

13

11

12

14

15

3

1

2

4

5

Power supply 85~265V AC

Sensor signal input

+5V DC

GND

8

6

7

9

10

18

16

17

19

20

1~5V DC_

+

4~20mA_

+

Wiring Diagram

+5V DC Brown UV SensorVout Blue

GND Black

Parameter Specification

1. Press + into the setting interface.

Parameter Setting

2. Press , you can choose the parameter which you want to setting(C-00, C-01 and C-02).

3. Press , you can choose the digit of C-00, C-01 and C-02. Then press and confirm the value you need.

4. Press for 3 seconds and comfirm and finish the setting.

6. Press + and back to the operate interface.

5. Press for less than 1 second and rerurn to the 2 step