Hazardous Area Lighting

Page 2: Catalogue Bajaj Luminaire Hazardous Area Lighting

HAZARDOUS AREA LIGHTINGHAZARDOUS AREA LIGHTING

INTRODUCTION

Flameproof Bulkhead Luminaire

Flameproof Luminaire For Fluorescent Tubular Lamp

Flameproof Non-integral Wellglass Luminaire

Flameproof Aviation Obstruction Light

Flameproof Control Gear Box

Increased Safety Non Integral Wellglass Luminaire

Increased Safety Integral Wellglass Luminaire

Control Gear Box for Increased Safety Luminaire

Flameproof Integral Wellglass Luminaire

Flame Proof Non-integral Flood Light

Page 3: Catalogue Bajaj Luminaire Hazardous Area Lighting

HAZARDOUS AREA LIGHTINGHAZARDOUS AREA LIGHTING

Hazardous Area Lighting

In the areas where flammable materials are manufactured, produced, processed or stored, mixing of flammable gases with air

is likely to happen in the atmosphere. If due to the electrical equipment installed in such areas, ignition takes place due to a

spark or fire, it can lead to a hazardous situation. Although the prime requirement is to avoid the occurrence of such conditions

where this is not practical, special methods of safeguarding electrical apparatus must be employed.

Care should be taken to avoid flammable or explosive atmospheres, inorder to have an ignition, both a flammable atmosphere

and means of ignition must exist simultaneously.

Types of Hazardous situations :

Depending on the presence of flammable material the hazardous areas are classified in to Hazardous Zones.

Typical illustration of Zone 0, Zone 1, Zone 2 areas

with source of ignition

ZONE 2

ZONE 1

ZONE 0(SOURCE)

ZONE 0

ZONE 1

ZONE 2

THE EXPLOSIVE ATMOSPHERE IS CONTINUOUSLY PRESENT

THE EXPLOSIVE ATMOSPHERE IS OFTEN PRESENT

THE EXPLOSIVE ATMOSPHERE IS ACCIDENTALLY PRESENT

A Zone in which an explosive mixture is continuously present (in the gaseous phase) inside a receptacle or a

closed chamber constitute Zone 'O’

A Zone in which an explosive mixture of Gas, Vapour or Dust is likely to occur in normal operations. In these areas

flameproof luminaires and accessories are used.

Flameproof Enclosure - is one which will withstand when all the covers and accessories are properly secured, an

internal explosion of the flammable gas or vapour through the joint gaps and flame paths provided in the enclosure.

Note: The term 'Flameproof' is synonymous with the term 'Explosion-proof' as used in USA or 'Explosion-Proof' type

'd' protection used in Germany and other Continental countries.

A Zone in which an explosive mixture is not likely to occur in normal operations and if it occurs will only exist for a

short time (Leaks or negligent use). In these areas, Increased Safety Luminaires are used and are generally

provided with gaskets and special lamp holders in case of fittings. These equipments are manufactured as per IS

8224/1976 and IS 6381/1972.

Page 4: Catalogue Bajaj Luminaire Hazardous Area Lighting

HAZARDOUS AREA LIGHTINGHAZARDOUS AREA LIGHTING

It should be noted that fittings complying with the requirements as specified in IS 8224/1976 are not suitable for gases or ovapour having ignition temperature below 200 C. The following is the list of gases or vapours known to have self/auto ignition

otemperature below 200 C.

1. Ethyl nitrate 2. Isopropyl nitrate3. Carbon disulphide 4. Acetaldehyde5. Diethyl ether 6. Diproplyl ether7. Dibutyl ether 8. Diamyl ether9. Dihexyl ether 10. Benxaldyhyde

11. Ethyl Methyl ether 12. Diethyl peroxide

Temperature Classes

Ignition temperature is the lowest temperature at which a flammable gas mixture ignites. Flammable vapours and gases can be

classified into temperature classes according to their ignition temperature. Surface temperature of the luminaire is likely to be

higher than ambient temperature due to heat generated during fire or explosion inside the enclosure. The maximum surface

temperature of the luminaire must always be lower than the ignition temperature of the gas mixture present in the air.

Luminaire of appropriate specified temperature class should be selected based on the ignition temperature of the gas.

Dust proof / Dust-tight

Luminaires are manufactured as per IS 4012 / IS 4013-1967 and are recommended to be installed in industries where in

addition to the recognized explosives, many other dusts including practically all organic and inorganic dust, (dust of metals are

flammable to some extent depending on the particle size), specific gravity of dust etc. are present.

Dusts have been broadly classified into the following groups.

Class 1 Dust which ignite and propagate flame readily, the source of heat required for ignition being small.

Class 2 Dust which ignite readily with flame but require a larger source of ignition.

Class 3 Dust which do not ignite.

Dust-tight luminaires are recommended for locations laden with Class 1 Dust. For other class of dust, dustproof lighting fittings

may be used.

Temperature Class Maximum Surface Temperature

of Luminaires ( C)

T1 450

T2 300

T3 200

T4 135

T5 100

T6 85

z

Page 5: Catalogue Bajaj Luminaire Hazardous Area Lighting

HAZARDOUS AREA LIGHTINGHAZARDOUS AREA LIGHTING

Group of Enclosures

I

II A

Gas or Vapour

Methane (fire damp)

Ammonia, Industrial mathane*, Blast furnace gas, Carbon monoxide, Propane, Butane, Pentane, Hexane, Heptane, Iso-Octane, Decane, Benzene, Xylene, Cyclohexane, Acetone, Ethyl methyl Ketone, Methyl acetate, Ethyl acetate, N-propyl acetate, N-butyl acetate, Amyl acetate, Chlorothylene, Methanol, Ethanol, ISO-butanol, N-Butanol, Amyl alcohol, Ethyl nitrate.

Hydrogen

II B

II C

1, 3-Butadine, Ethylene, Diethyl ether, Ethylene oxide, Town gas, Coke-oven gas.

Drip proof IP 22

Rain proof IP 23

Splash proof IP 34

Dustproof / Splashproof IP 54

Dustproof / Jetproof IP 55

Dust-tight / Jetproof IP 65

Ingress Protection System for Enclosures (IP)

This system outlined in IS 2147 is designed to indicate the standard degree of protection: (a) from ingress of solids and (b) from

ingress of liquids which enclosures may exhibit and must not be confused with explosion protection techniques.

For luminaires the following IP numbers commonly apply :

Higher the numerical of the first and second characteristic, the greater degree of protection the enclosure offers. E.g. Jetproof

IP 55 meets all the less onerous degrees such as IP 22, IP 23, IP 34 and IP 54.

Testing Authorities

All our Flameproof and Increased safety luminaires are tested and Certified by Central Institure of Mining and Fuel Research

(CIMFR), Dhanbad.

Standards

(a) Flameproof Construction : IS:2148-2004 (IEC 60079-1/2001)

(b) General design, rating, performance & T-class : IS:13346-2004 (IEC 60079-0/2000)

(c ) Weatherproof construction IP-65 : IS:12063-1987 (IEC 60529/1989)

Table 3 of IS 2148/1981

Group of Enclosures Suitable for Particular Flammable Gas or Vapour (Clauses 1.4 and 3.1.2)

*Industrial Methane includes methane mixed with not more than 10% by volume of hydrogen.Town gas may contain not more

than 57% by volume of hydrogen and not more than 16% by volume of carbon monoxide, the remainder being a mixture of

paraffin hydrocarbons and inert gas.

---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

Note :

Due to our continuous efforts in developing products, improvement - Bajaj Electricals Limited reserves the right to make changes in the

design and data without any prior notice.

Page 6: Catalogue Bajaj Luminaire Hazardous Area Lighting

BJFB 150/200 BC/ES (LM 6)

Luminaire Body

Lamp

Temperature Range

CIMFR Certificate

Epoxy finish Cast Aluminium LM6 housing.

Toughened Type A flat glass.

Two cable entries of 3/4” BS conduit are provided.

Lamp holder suitable for lamp type will be provided (2 pin BC / 3 pin BC / E 27)

Sui table for 100W/150W/200W GLS, 80W/125W HPMV, 70W SV/MH/150W MH (E27) 160W MLL, 26W CFL - Retrofit.

80W MV/70W SV/ 70W MH/100W GLS - T4

125MV/150W MH/150W GLS/200W GLS /160W MLL T3

26W CFL - Retrofit - T6

Suitable for Zone 1 & 2 areas where explosive gasses specified under gas groups IIA & IIB are present. This is a non integral luminaire suitable for indoor application. Separate control gear to be used in case of HID lamps.

CIMFR/TC/SR/H909 DATED 08.02.2008

Flameproof Bulkhead Luminaire

Luminaire Body

Lamp

Temperature Range

Ingress Protection

CIMFR Certificate No

Note

Cast Aluminium LM6 housing with Epoxy finish. Heat resistant borosilicate tubular glass held in two aluminium cups. Two cable entries of 3/4” BS conduit are provided.

Single or Twin 36W /40 W Fluorescent Tubular lamp/28W T5 lamp. Special variant for 18W/20 W FTL also available.

T6

IP 65

Suitable for Zone 1 & 2 areas where explosive gasses specified under gas groups IIA & IIB are present.

CIMFR/TC/SR/H798 DTD 11.01.2008

External Stove Enameled Reflector can be provided as an additional feature

Flameproof Luminaire For Fluorescent Tubular Lamp

BJFFTL 136/236, 140/240, 128/228

228 135

380

BJFFTL-140 BJFFTL-240

235

170

267

170

125

235

BJFFTL-140/240

1590

235

Page 7: Catalogue Bajaj Luminaire Hazardous Area Lighting

Luminaire Body

Lamp

Temperature Range

Ingress Protection

CIMFR Certificate No

Cast Aluminium LM6 housing with Epoxy finish. Heat resistant and toughened glass enclosure type A with BC/E27 lamp holder Painted MS wire guard. Two cable entries of 3/4” BS conduit are provided. Separate flameproof control gear box of suitable rating to be used for HID lamps.

Suitable for 80/125W MV, 70W SV/MH, 150W MH (E27), 200W GLS, 160W MLL, 23W /26W Retrofit CFL lamp.

150W MH (E27), 200W GLS, 160W MLL - T3125W MV - T480W MV/ 70W SV/ 70W MH - T523W/26W Retrofit CFL - T6

Ideal for use in Zone 1 & 2 areas where explosive gasses specified under gas groups IIA & IIB are present.

IP 65

CIMFR/ TC/ SR/ H 1136 DATED 19.03.2008

Flameproof Non-integral Wellglass Luminaire

BJFW 80/125 MV NI BC/ES LM 6

247

402

Luminaire Body

Lamp

Temperature Range

Ingress Protection

CMRI Certificate No

Cast Aluminium LM6 housing with Epoxy finish. Heat resistant and toughened glass enclosure type A. Painted MS wire guard. Two cable entries of 3/4” BS conduit are provided. Available in cast iron version for special application areas also. This is a non-integral luminaire. Separate flameproof control gear box to be used as per the lamp rating.

250 W HPMV, 400W HPMV, 250W HPSV, 400W HPSV, 400W MH lamp.

250W/400W HPMV - T3, 250W HPSV - T5, 400W HPSV/MH - T4

Suitable for use in Zone 1 & 2 areas where explosive gasses specified under gas groups IIA & IIB are present.

IP 65

CMRI/TC/P/H/382 DTD 18.08.2006

BJFW 400 MV CA (NI)BJFW 400 SV/MH CA (NI) / BJFW 250 SV (NI)

Flameproof Non-integral Wellglass Luminaire

53

0

Ø335

100100

A = 3 Nos.,Ø12.5 HOLE

AAA

Page 8: Catalogue Bajaj Luminaire Hazardous Area Lighting

BJFW 250 MV I CABJFW 150 SV/MH I

Luminaire Body

Lamp

Temperature Range

Ingress Protection

CIMFR Certificate No

Cast Aluminium LM6 housing with Epoxy finish. Heat resistant and toughened glass enclosure type A. Painted MS wire guard. Two cable entries of 3/4” BS conduit are provided. This is an integral luminaire HID Ballast & accessories fitted inside the housing.

Suitable for 150W HPSV/MH lamp, 250 HPMV lamp.

T 4

Ideal for use in Zone 1& 2 areas where explosive gasses specified under gas groups IIA & IIB are present.

IP 65

CMRI/TC/P/H 378 DATED 18.08.2006

Flameproof Integral Wellglass Luminaire For HPMV/HPSV And Metal Halide Lamp

Luminaire Body

Lamp

Temperature Range

Ingress Protection

CIMFR Certificate No

Note

Cast Aluminium LM6 housing with Epoxy finish. Heat resistant and toughened glass enclosure-type A. Painted MS wire guard. Two cable entries of 3/4” BS conduit are provided. This is an integral luminaire. HID ballast and accessories fitted inside the housing.

Suitable for 80W/125 W HPMV, 70W HPSV/MH lamp.

T 4

Ideal for use in Zone 1& 2 areas where explosive gasses specified under gas groups IIA & IIB are present.

IP 65

CIMFR/TC/SR/H840 DATED 24.01.2008

This luminaire can also be used as non integral for 250W MV/150SV/150 MH BJFW 250 W MV (NI), BJFW 150 W SV (NI), BJFW 150 W MH (NI)

Flameproof Integral Wellglass Luminaire For HPMV/HPSV and Metal Halide Lamp

BJFW 80/125 MV I CA BC/ES

BJFW 70 SV/MH I

245

480

BJFW 250 MV I

53

0

Ø247

Page 9: Catalogue Bajaj Luminaire Hazardous Area Lighting

Luminaire Body

Lamp

Temperature Range

Ingress Protection

CMRI CERTIFICATE NO

Cast Aluminium LM6 Epoxy finish lamp housing. Heat resistant and toughened flat glass Type A. One Cable entry through 3/4” BS conduit. This is a non integral luminaire and suitable flameproof control gearbox should be separately used.

Ideal for use in zone 1 & 2 areas where explosive gasses specified under gas groups IIA & IIB are present.

Suitable for 250 HPMV/250W HPSV/400W HPSV/400W MH.

250WMV - T5 , 400W SV/MH - T4, 250W SV T6.

IP 65

CMRI/TC/P/H 387 DTD. 21.08.2006

Flameproof Non-integral Flood Light

BJFFL 250/400 NI

Luminaire Body

Lamp

Temperature Class

Ingress Protection

CMRI CERT.NO

Cast aluminum LM6 yellow epoxy powder coated housing. Heat resistant and toughened type A glass enclosure. Two cable entries of 3/4” BS conduit are provided. Ideal for use in zone 1 & 2 areas where explosive gasses specified under gas groups IIA & IIB are present.

Suitable for Neon spiral lamp 75VA

T6

IP 65

CMRI /TC/P/H354 dt. 10th Aug 2006.

Flameproof Aviation Obstruction Light

BJFAOL 01

70

0

Ø3

75

100 100

500

BJFFL 250/400 MV NI

49

5

Ø38

Ø245

BJFAOL-01

Page 10: Catalogue Bajaj Luminaire Hazardous Area Lighting

BJFC 80W/125W/250W MV CABJFC 70W/150W SV/MHBJFC 400 MV/SV/MH

Housing

Lamp

Temperature Range

Ingress Protection

CIMFR Certificate No

Die-cast aluminium LM6 housing. Completely wired with control gear accessories. Three cable entries of 3/4” BS conduit are provided. Ideal for use in ZONE 1 & 2 areas where explosive gasses specified under gas groups IIA & IIB are present.

Versions available for 80W/125W/250W HPMV lamp, 70W/150W HPSV/Metal Halide lamp and 3 X 26W CFL. Also available for 400W HPMV/400W HPSV/MH lamp.

T6

IP65

CIMFR/TC/SR/H800 DTD. 15/01/2008 for 80W/125W/250 HPMV, 70/150SV/MHCIMFR/TC/SR/H837 DTD. 23/01/2008 for 400W HPMV/HPSV/MH lamps.

Flameproof Control Gear Box

Luminaire Body

Lamp

Ingress Protection

Temperature Class

CMRI Certification

Applicable standards and certification

Cast Aluminium LM6 housing with Epoxy finish. Heat resistant well glass cover. Painted MS wire guard. Two cable entries of 3/4” BS conduit are provided. This is a dustproof, dust tight, totally enclosed, increased safety non-integral luminaire. Separate increased safety control gear box to be used as per Zone 2 the lamp rating.

Suitable for 150/200W GLS, 160W MLL , 80W/125W HPMV, 70W HPSV - Elliptical, 23 W Retrofit CFL.

IP 65

CMRI/TC/P/H1335 DTD 10.11.1998

lS : 2147-1962 Specification for Degree of protectionlS : 8224-1976 Specification for Electric Lighting Fittings for Divn. 2 areaslS : 6381/1972 Specification of Electrical Apparatus with type of

protection 'e'lS : 6381/1972 Specification of construction of Electrical Apparatus with

type of protection 'e'lS : 13947 (part 1) 1993 for lP 65

Increased Safety Non-Integral Wellglass Luminaire

BJDP/DT/TE/ISW-200 LM6 NI

Volts 250 Max. GLS HPMV MLL SV CFL

150W 200W 80W 125W 160W 70W 23W

Temperature Classification T5 T5 T6 T5 T5 T6 T6

320

210

33

5 20

5

235

238

11

1

Page 11: Catalogue Bajaj Luminaire Hazardous Area Lighting

Luminaire Body

Lamp

CMRI Certification

Applicable standards and certification

Cast Aluminium LM6 housing with Epoxy finish. Heat resistant and toughened glass cover-type A. Painted MS wire guard. Two cable entries of 3/4” BS conduit are provided.

Ideal for use in areas where explosive or ignitable gases are present (Division 2 areas).

Ingress protection: IP 65

Suitable for 80/125W MV lamp, 70W HPSV lamp. HID ballasts and accessories wired inside the housing. It can also be used for 250W HPMV as non integral luminaire. Separate control gear box to be used for 250W HPMV version - BJISW 250 MV NI.

This luminaire has been tested and certified by CMRI, Dhanbad vide their letter Ref. No.CMRI/TC/P/H1260 DATED 14-10-1999CMRI/TC/ADDEN/H193 DATED 16-02-2000CCE No. R1(1) 136/ALPINE/418 dated 15-02-2000

IS : 2147-1962 Specification for Degree of protectionlS : 8224/1976 Specification for Electric Lighting Fittings for Divn.2 areaslS : 6381/1972 Specification of construction of Electrical Apparatus with type of protection 'e'lS : 13947 (part 1) 1993 for IP 65.

Luminaire Body

Lamp

Ingress Protection

CMRI Certification

Applicable standards and certification

Cast Aluminium LM6 housing with Epoxy finish. Heat resistant well glass cover, Ideal for use in Zone 2. Painted MS wire guard. Two cable entries of 3/4” BS conduit are provided. This is a dustproof, dust tight, totally enclosed, increased safety non-integral luminaire. Separate increased safety control gear box to be used as per the lamp rating.

Suitable for 150/200W GLS, 160W MLL , 80W/125W HPMV, 70W HPSV - Elliptical, 23 W Retrofit lamp.

IP 65

CMRI/TC/P/H1455 Dated 26.11.98 for BJISW

lS : 2147-1962 Specification for Degree of protectionlS : 8224-1976 Specification for Electric Lighting Fittings for Zone 2 areaslS : 6381/1972 Specification of Electrical Apparatus with type of protection 'e'lS : 6381/1972 Specification of construction of Electrical Apparatus with type of protection 'e'lS : 13947 (part 1) 1993 for lP 65

Increased Safety Non-Integral Wellglass Luminaire

BJISW 80/125 MV NI/70 SV NI BJISW 80/125 MV (I)

BJISW 70SV (I)

210

320

Volts 250 Max. GLS HPMV BLL SV CFL

150W 200W 80W 125W 160W 70W 23W

Temperature Classification T5 T5 T6 T5 T5 T6 T6225

390

Increased Safety Integral Wellglass Luminaire

Page 12: Catalogue Bajaj Luminaire Hazardous Area Lighting

BJISCG 80/125/250 MVBJISCG 70/150 SV

HOUSING

Lamp

Ingress Protection

CMRI Certificate No

Die-cast aluminium LM6 housing. Completely wired with control gear accessories. Three cable entries of 3/4” BS conduit are provided.

Ideal for use in Zone 1 & 2 areas where explosive or ignitable gas mixtures are present for a short period.

Suitable for 80/125W HPMV, 70W HPSV, 150W HPSV, 250MV lamp. Prewired with open construction ballast and accessories suitable for lamp rating.

IP 65

CMRI /TC/P/SL/H1454 DTD 26/11/1998 for 80W/125W HPMV, 70W HPSVCMRI/TC/P/H1361 DTD 12.01.1999 for 250W HPMV, 150W HPSV

210

103

215

200 C/C

102 C/C210

Control Gear Box for Increased Safety Luminaire

Page 13: Catalogue Bajaj Luminaire Hazardous Area Lighting

FLAMEPROOF LUMINAIRES PRODUCT RANGE DETAILS

SR. NO. CIMFR REVALIDATION CIMFR SUPPLIMENTARY ITEM CAT NOS. LAMP RATING TEMP. IP ZONE GASCERTIFICATE CERTIFICATE TO RANGE GROUPNO. & DATE REVALIDATION

CERTIFICATE NO. & DATE

1 CIMFR/TC/SR/H840 CIMFR/TC/S/693 BJFW - 250 BJFW - 250 MV (NI) 250 W HPMV T 3 IP 65 1 & 2 IIA & IIB

DTD. 24.01.2008 DTD.19.11.2008 FLAMEPROOF/WP BJFW - 80 MV (I) 80 W HPMV IP 65 1 & 2 IIA & IIB

WELLGLASS BJFW - 125 MV (I) 125 W HPMV T 4 IP 65 1 & 2 IIA & IIB

LUMINAIRES BJFW - 70 SV (I) 70 W HPSV IP 65 1 & 2 IIA & IIB

BJFW - 70 MH (I) 70 W MH IP 65 1 & 2 IIA & IIB

BJFW - 150 SV (NI) 150 W HPSV T 4 IP 65 1 & 2 IIA & IIB

BJFW - 150 MH (NI) 150 W MH T 4 IP 65 1 & 2 IIA & IIB

BJFW - 150 MH (E27) (I) 150 W MH (E27) T 3 IP 65 1 & 2 IIA & IIB

BJFW - 3X26 CFL (I) 3X26 W CFL T 6 IP 65 1 & 2 IIA & IIB

BJFW - 300 GLS 300 W GLS IP 65 1 & 2 IIA & IIB

2 CIMFR/TC/SR/H1136 CIMFR/TC/S/694 BJFW - 80/125 BJFW - 80 MV (NI) 80 W HPMV T 5 IP 65 1 & 2 IIA & IIB

DTD. 19.03.2008 DTD.19.11.2008 FLAMEPROOF/WP BJFW - 125 MV (NI) 125 W HPMV T 4 IP 65 1 & 2 IIA & IIB

NON-INTEGRAL BJFW - 70 SV (NI) 70 W HPSV T 5 IP 65 1 & 2 IIA & IIB

WELLGLASS BJFW - 70 MH (NI) 70 W MH T 5 IP 65 1 & 2 IIA & IIB

LUMINAIRES BJFW - 150 SV (E27)(NI) 150 W MH (E27) T 3 IP 65 1 & 2 IIA & IIB

BJFW - 1X23 CFL (NI) 23 W CFL T 6 IP 65 1 & 2 IIA & IIB

BJFW - 3X26 CFL (NI) 3X26 W CFL T 6 IP 65 1 & 2 IIA & IIB

BJFW - 200 GLS (NI) 200 W GLS T 3 IP 65 1 & 2 IIA & IIB

BJFW - 160 MLL (NI) 160 W MLL T 3 IP 65 1 & 2 IIA & IIB

3 CIMFR/TC/SR/H800 CIMFR/TC/S/696 BJFC - 80/125/250 BJFC - 80 MV 80 W HPMV IP 65 1 & 2 IIA & IIB

DTD.15.01.2008 DTD.19.11.2008 FLAMEPROOF/WP BJFC - 125 MV 125 W HPMV IP 65 1 & 2 IIA & IIB

CONTROL BJFC - 250 MV 250 W HPMV T 6 IP 65 1 & 2 IIA & IIB

GEAR BOX BJFC - 70 SV 70 W HPSV T 6 IP 65 1 & 2 IIA & IIB

BJFC - 70 MH 70 W MH T 6 IP 65 1 & 2 IIA & IIB

BJFC - 150 SV 150 W HPSV T 6 IP 65 1 & 2 IIA & IIB

BJFC - 150 MH 150 W MH T 6 IP 65 1 & 2 IIA & IIB

BJFC - 3X26 CFL 3X26 W CFL T 6 IP 65 1 & 2 IIA & IIB

4 CIMFR/TC/SR/H837 CIMFR/TC/S/697 BJFC - 400 MV BJFC - 400 MV 400 W HPMV T 6 IP 65 1 & 2 IIA & IIB

DTD.23.01.2008 DTD.19.11.2008 FLAMEPRROF/WP BJFC - 400 SV 400 W HPSV T 6 IP 65 1 & 2 IIA & IIB

CONTROL BJFC - 400 MH 400 W MH T 6 IP 65 1 & 2 IIA & IIB

GEAR BOX

5 CIMFR/TC/SR/H909 CIMFR/TC/S/695 BJFB - 150/200 BJFB - 80 MV 80 W HPMV T 4 - 1 & 2 IIA & IIB

DTD.08.02.2008 DTD.19.11.2008 FLAMEPROOF BJFB - 125 MV 125 W HPMV T 3 - 1 & 2 IIA & IIB

BULK HEAD BJFB - 70 SV 70 W HPSV T 4 - 1 & 2 IIA & IIB

LUMINAIRE BJFB - 70 MH 70 W MH T 4 - 1 & 2 IIA & IIB

BJFB - 150 SV 150 W HPSV T 3 - 1 & 2 IIA & IIB

BJFB - 150 MH 150 W MH T 3 - 1 & 2 IIA & IIB

BJFB - 160 MLL 160 W MLL T 3 - 1 & 2 IIA & IIBBJFB - 1X26 CFL 26 W CFL T 6 - 1 & 2 IIA & IIBBJFB - 100 GLS 100 W GLS T 4 - 1 & 2 IIA & IIBBJFB - 150 GLS 150 W GLS T 3 - 1 & 2 IIA & IIBBJFB - 200 GLS 200 W GLS T 3 - 1 & 2 IIA & IIB

6 CIMFR/TC/SR/H798 CIMFR/TC/S/H438 BJFFTL - 140 BJFFTL - 140 1X40 W FTL T 6 IP 65 1 & 2 IIA & IIBDTD.11.01.2008 DTD.03.09.2008 FLAMEPROOF/WP BJFFTL - 240 2X40 W FTL IP 65 1 & 2 IIA & IIB

FLUORESCENT BJFFTL - 136 1X36 W FTL T 6 IP 65 1 & 2 IIA & IIBCIMFR/Amend/FLP/Oct./588 TUBE LIGHT BJFFTL - 236 2X36 W FTL IP 65 1 & 2 IIA & IIBDTD.17.10.2008 LUMINAIRE BJFFTL - 120 1X20 W FTL T 6 IP 65 1 & 2 IIA & IIB

BJFFTL - 220 2X20 W FTL IP 65 1 & 2 IIA & IIBBJFFTL - 118 1X18 W FTL T 6 IP 65 1 & 2 IIA & IIBBJFFTL - 218 2X18 W FTL IP 65 1 & 2 IIA & IIBBJFFTL - 128 1X28 W (T5) IP 65 1 & 2 IIA & IIBBJFFTL - 228 2X28 W (T5) IP 65 1 & 2 IIA & IIBBJFFTL - 114 1X14 W (T5) IP 65 1 & 2 IIA & IIBBJFFTL - 214 2X14 W (T5) IP 65 1 & 2 IIA & IIBBJFFTL - 1X20 CFL 1X20 W CFL T 6 IP 65 1 & 2 IIA & IIB

7 CIMFR/TC/SR/H808 BJFJB - 100 BJFJB - 100 - - IP 65 1 & 2 IIA & IIBDTD.16.01.2008 FLAMEPROOF/WP

JUNCTION BOX

Page 14: Catalogue Bajaj Luminaire Hazardous Area Lighting

FLAMEPROOF LUMINAIRES PRODUCT RANGE DETAILS

SR. NO. CIMFR REVALIDATION CIMFR SUPPLIMENTARY ITEM CAT NOS. LAMP RATING TEMP. IP ZONE GASCERTIFICATE CERTIFICATE TO RANGE GROUPNO. & DATE REVALIDATION

CERTIFICATE NO. & DATE

8 CMRI/TC/P/H382 BJFW - 400 MV (NI) BJFW - 400 MV (NI) 400 W HPMV T 3 IP 65 1 & 2 IIA & IIBDTD.18.08.2006 FLP/WP BJFW - 400 SV (NI) 400 W HPSV T 4 IP 65 1 & 2 IIA & IIB

WELLGLASS BJFW - 400 MH (NI) 400 W MH T 4 IP 65 1 & 2 IIA & IIBREVALIDATION NOT LUMINAIRE BJFW - 250 SV (NI) 250 W HPSV T 5 IP 65 1 & 2 IIA & IIBREQUIRED AS TESTEDBYCMRI AS PER REVISED BIS STANDARDS

9 CMRI/TC/P/H387 BJFFL-250/400 MV BJFFL - 250 MV (NI) 250 W HPMV T 5 IP 65 1 & 2 IIA & IIBDTD.21.08.2006 NON-INTEGRAL BJFFL - 250 SV (NI) 250 W HPSV T 6 IP 65 1 & 2 IIA & IIB

FLAMEPROOF/WP BJFFL - 400 SV (NI) 400 W HPSV T 4 IP 65 1 & 2 IIA & IIBREVALIDATION NOT FLOOD LIGHT BJFFL - 400 MH (NI) 400 W MH T 4 IP 65 1 & 2 IIA & IIBREQUIRED AS TESTED LUMINIAREBYCMRI AS PER REVISED BIS STANDARDS

10 CMRI/TC/P/H378 BJFW - 250 MV (I) BJFW - 250 MV (I) 250 W HPMV T 4 IP 65 1 & 2 IIA & IIBDTD.18.08.2006 FLAMEPROOF/WP BJFW - 150 SV (I) 150 W HPSV T 4 IP 65 1 & 2 IIA & IIB

WELLGLASS BJFW - 150 MH (I) 150 W MH T 4 IP 65 1 & 2 IIA & IIBREVALIDATION NOT LUMINIAREREQUIRED AS TESTEDBYCMRI AS PER REVISED BIS STANDARDS

11 CMRI/TC/P/H354 BJFAOL - 01 BJFAOL - 01 NEON SPIRAL T 6 IP 65 1 & 2 IIA & IIBDTD.10.08.2006 FLP/WP LAMP 75 VA

AVIATIONREVALIDATION NOT OBSTRUCTIONREQUIRED AS TESTED LIGHT BYCMRI AS PER REVISED BIS STANDARDS

INCREASED SAFETY LUMINAIRES

SR. ITEM CAT CMRI CERTIFICATE CMRI ADDENDUMS & SUPPLIMENTARY

NO. NO. & DATE NOS. DATE CERTIFICATES

NOS. DATE ADDITIONS

1 BJDP/DT/TE/ISW-200 INCREASED SAFETY BJDP/DT/TE/ISW-200 CMRI/TC/P/H1335 CMRI/TC/P/H1259 23 W CFL LAMP 70 W HPSV LAMP WITH

WELLGLASS FITTING SUITABLE FOR INCREASED SAFETY DTD.10.11.1998 DTD.14.10.1999 BUILT IN IGNITOR LAMP HOLDER 2 PIN / 3 PIN / E 27

150 / 200 W GLS LAMP 80 / 125 W HPMV LAMP NON INTEGRAL BAKELITE / GFP / PORCELAIN CONNECTOR

160 W MLL LAMP IP 65 WELLGLASS FITTING

2 BJISW - 80/125 INCREASED SAFETY BJISW - 80/125 CMRI/TC/P/H1455 CMRI/TC/S/H1365 23 W CFL LAMP 70 W HPSV LAMP

WELLGLASS FITTING SUITABLE FOR INCREASED SAFETY DTD.26.11.1998 DTD.15.11.1999 WITH OR WITHOUT BUILT IN ADOPTOR

150 / 200 W GLS LAMP 80 / 125 W HPMV LAMP NON INTEGRAL LAMP HOLDER 2 PIN/ 3 PIN / E 27

160 W MLL LAMP IP 65 WELLGLASS FITTING

3 BJISW - 80/125 (I) & BJISW - 250 MV (NI) BJISW - 80/125 (I) CMRI/TC/P/H1260 CMRI/TC/ADDEN/H193 BJISW - 80/125 (I) INTEGRAL & BJISW - 250 MV (NI)

INCREASED SAFETY WELLGLASS FITTING INCREASED SAFETY DTD.14.10.1999 DTD.16.02.2000 NON INTEGRAL INCREASED SAFETY

SUITABLE FOR 80/125 W/250 W HPMV LAMP INTEGRAL WELLGLASS FITTING

70 W HPSV LAMP WITH BUILT IN IGNITOR WELLGLASS FITTING

70 W /150 W HPSV LAMP WITHOUT IGNITOR IP 65

4 BJISCG - 80/125 MV INCREASED SAFETY/ WP BJISCG - 80/125 CMRI/TC/P/SL/H1454 CMRI/TC/S/H1310 (A) 70 W (B) CONNECTOR AS PORCELAIN / GFP / ELMEX

CONTROL GEAR BOX IP 65 INCREASED SAFETY DTD.26.11.1998 DTD.29.10.1999

CONTROL GEAR BOX

5 BJISCG - 250 HPMV INCREASED SAFETY BJISCG - 250 CMRI/TC/P/H1361

CONTROL GEAR BOX SUITABLE FOR INCREASED SAFETY DTD.12.11.1999

250 W HPMV / 150 W HPSV LAMP IP 65 CONTROL GEAR BOX