NX Series Controllers
One Family of Programmable Logic Controllers for Every Application
OE MAX??Maximizing Operating Earnings for OEMs
OE MAX is a unique
brand that delivers the best
products from all over
the world to you by a
network of distributors who
understand your control
and automation needs.
OE MAX is a value-driven global brand offeringcompetitive control products and performance-designed automation components developedspecifically to help small independent machinebuilders maximize their operating earnings. OE MAXoffers the most complete and competitive one-stopservice for top quality, reliable components such asPLCs, distributed I/O, servo drives, operator interfacepanels and other industrial control products to meetthe needs of original equipment manufacturers.
With our professional team, we search the world forproducts that offer the best quality for yourapplication. We understand the importance ofinstilling confidence and trust in establishing long-term relationships with all our customers, regardlessof size. We seek to build relationships that lead tomutual success for the benefit of our people, theirfamilies, and their communities.
OE MAX provides performance-designed automationcomponents at a price less than you expect to pay tohelp independent OEMs maximize operating earnings.Moreover, OE MAX optimizes the cost of equipmentand is committed to delivering the most cost-effectivecontrol components that meet the specifications foryour machine.Through our catalogs and full featured web site, youwill find the most suitable automation products thatmeet your specific needs. OE MAX will grow to meetyour needs through the continued introduction of newproducts and strives to be one of the best suppliers ofindustrial automation products.
2 I ??????????????????????????
The NX series is a family of small, modular programmable controllers from OE MAX. They deliverpower and flexibility with a wide range of communication configurations, user features andmemory options. The NX series offers a breadth of controllers that satisfies a wide variety ofOEM applications. This ensures youll find a world class PLC that fits your application as easily asone that fits your budget. This integrated and compact PLC series is equipped with advancedcontrol functions, easily handling most OEM applications. In addition, the NX series productshave built-in real-time clocks and user-defined communication functions, such as ASCII,satisfying the diverse needs of original equipment manufacturers
All members of the NX series share a common architecture and use the same industry leadingWinGPC programming software, so you dont have to reprogram or learn a new system as yourneeds change. With the NX series controllers, you can finally have the ideal blend of functionalityand compact size, at a price that is more reasonable than you might expect.
NX Series Controllers
NX Series Programmable Logic Controllers
0C to +55C (32F to 131F)
-25C to +70C (-13F to 158F)
30 ~ 85% RH (Non-condensing)
30 ~85% RH (Non-condensing)
I/O Terminal (ac) Frame Ground (Power Unit), 1500V ac for 1 minute
I/O Terminal (dc) Frame Ground (Power Unit), 500V ac for 1 minute
I/O Terminal Frame Ground (Power Unit), over 100 M?(at 500 mega V dc)Isolation resistance
Operating
Storage
Vibration
Shock
Noise Immunity
15g peak acceleration (11 ms duration) 3 times, each X, Y, Z direction
10 Hz to 55Hz 1 sweep per minute,0.75mm peak to peak , 10 minutes per axis ( X,Y,Z)
1500Vp-p with 50 ns to 1 ?s pulse width (generated by noise simulator)
Temperature
Humidity
Withstand Voltage
Item Specifications
IP20(No corrosive gas, No excessive dust.)
Operating
Storage
Environment
NX Series Common Specifications
?????????????????????????? I 3
Features of NX7S?Control 10,14,20,28,40,48 digital I/O points?2 serial ports (1 RS-232C, 1 RS485 with Modbus RTU)?Program memory size up to 2K words?Built-in backup flash memory?Built-in HSC, Pulse output(for TR output unit only)
Features of NX7?Basic control to 28, 48 points and up to 104 digital I/O points?Enable 2 expansion unit?2 serial ports (2 RS232C/RS485 with Modbus RTU)?Program memory size up 9K words?Built-in HSC, Pulse catch, Pulse output
(for TR output unit)?Built-in real-time clock, PID function
The perfect controller for
small applications and small
budgets. This little powerhouse
is both compact and inexpensive,
but it's big on performance--
providing high-speed advanced
networking and a full suite of
control capabilities. Among the
advantages of the NX7 are a
compact design that takes up
little panel space and fast
program scan time that keeps
your machines on the
cutting edge.
NX7 Series Micro Logic Controller
Model Classification SeriesNX7S
NX7S-10ADRNX7S-14ADRNX7S-20ADRNX7S-28ADRNX7S-40ADRNX7S-48ADR
NX7S-10ADTNX7S-14ADTNX7S-20ADTNX7S-28ADTNX7S-40ADTNX7S-48ADT
AC100/220AC100/220AC100/220AC100/220AC100/220AC100/220
20 points28 points40 points48 points
10 points14 points
BasicPoints
PowerSupply
DC IN/ Relay out
DC IN/ TR(sink) Out
NX7
NX7-28ADRNX7-28DDRNX7-48ADRNX7-48DDR
NX7-28EDR
NX7-28ADTNX7-28ADTNX7-48ADTNX7-48ADT
NX7-28EDTExpansion28 points
28 points
48 points
BasicPoints
PowerSupply
DC IN/ Relay Out
DC IN/TR(sink) Out
AC100/220DC 24V
AC100/220DC 24V
DC 24V
4 I ??????????????????????????
NX7 Series Micro Logic Controller
2 K words2.5 K Words3096 points
2048 points ( Keep Data )2048 words
9 K words2.5 K Words3096 points
2048 points ( Keep data )2048 words (Keep data)
--2
RS-232C (D-sub 9pin)RS485 (RJ45 8pin)
--
Built-inYes (8 loop)
EEPROMEEPROM200 mA
SRAM or EEPROMSRAM w/Battery
400 mADIN Rail or Panel
100*90*80 100*90*80 146*90*80
Yes (Com2 port)Yes (Com2 port)
1 Ch (4KHz/2 Phase, 8KHz/1 Phase), 32Bit, Note)
4 points2 Ch(for TR Output unit), PWM/Pulse(PTO) mode, 10KHz, 32Bit, Note)
2 Units2
RS-232C/RS485 (Dsub 9pin)RS485 (RJ45 8pin)
Program MemoryData Memory
Internal relayKeep relayData register
Basic I/O PointsMaximumBase I/ONo. of InputNo. of Output
Expansion I/O PointsExpansion Quantity
Communication PortCOM1COM2Modbus RTUUser define Protocol
Special FunctionHigh Speed CounterInput Pulse CatchPulse OutputReal Time ClockPID Function
Program BackupData BackupService Power(24Vdc)MountingDimension(W*H*D)
Item10xxx 14xxx 20xxx
NX7S NX728xxx 40xxx 48xxx 28xxx 48xxx
2816 points12 points
TR(sink) RelayDC 24V
N/ADIN Rail or Panel
100*90*80
ItemNX7-28EDT
NX7NX7-28EDR
NX7 Specifications
NX7 Expansion Unit
Note 1) Over ROM version 2.20
I/O PointsNo. of InputNo. of Output
I/O TypeType of InputType of Output
Input PowerMountingDimension(W*H*D)
101064
141486
2020128
28281612
40402416
48482820
8428161228
10448282028
?????????????????????????? I 5
Whatever your control
needs are, you will find an
answer with the NX70 series.
The NX70 is filled with
features and options designed to
handle an extensive range of
OEM applications. Advantages of
the NX70 include: Scalable
program memory and backplane
options to ensure you only buy
what you need. A wide range of
optional I/O units to match your
machines' unique specifications.
Run time editing for faster
machine start-up, commissioning
and process improvements,
without costly down-time. Best
of all, you get all this
functionality and quality at a
really great price.
Features of NX70
1. Fast, powerful processorsHigh speed basic instructions-performance-0.2?sec/STEP
2. Control up to 384 digital I/O pointsThe 12-slot NX70 allows up to 384 points (192 points usingterminal blocks)
3. Various I/O types and specialty unitsDC24V (16/32 points),AC110/220 Input, Relay,TR(16/32points),Analog Input/Output,RTD/TCInput,HSC(1,2,4CH),Position Control(2,4 Axes), CCU+/SCUcommunication and MWLINK/Remote/DeviceNet Link unitcan be used
4. Range of I/O base options (up to 12 slot) When configuring a system, PLC NX Series enables you tochoose a backplane from 2, 3, 5, 6, 8, 10, and 12 slots
5. High capacity programming and memory backup option Program memory size is from 9.6k words (NX70-CPU70P1)up to 20k words (for NX70-CPU70P2). Built-in flash EEPROMretains all ladder logic
6. Built-in PID capabilities Supports 8-loop PID controls (Only for NX70-CPU70P2 unit)
7. Built-in RTC (Real Time Clock) Built-in real time clock supports programming by time anddate. (Only for NX70-CPU70P2 unit)
8. Built-in RS 232C and RS 485, 2port (NX70-CPU70p2 unit)Two communication channels for simple connectivity tocomputers, operator interface, modem and other controllersto exchange large volumes of data with high speed. COM2port supports user defined communications to connect you tobarcode readers, Ac drive, modbus slave, or servos. (Binarycommunications available)
9. Superior diagnosticsSelf-diagnostics to minimize system errors and to maximizediagnostic efficiency
NX70 Series Small Logic Controller
10. WinGPC programming softwareWinGPC programming software lets you create, modify andmonitor CPU, forced I/O, I/O configuration. It is a powerful,easy-to-use tool for program upload/download
6 I ??????????????????????????
System Configuration
NX70 Series Small Logic Controller
Processing SpeedProgrammingProgram MemoryData MemoryMemory Back UpMax. I/O PointsMax. I/O UnitsCommunication Port
COM1COM2Modbus Slave CommunicationUser Defined Communication
Real Time ClockAdditional Program Back-up
Item NX70-CPU70P1 NX70-CPU70P20.2 us / Step (Basic)
Ladder9.6 K words2K words
SRAM with Battery (Progam & Data)384 points
12 units1 2
RS232C/485 with DSUB 9Pin Connector
N/AN/A
N/AN/A
YesYes
Built inBuilt in Flash Memory
20 K words4K words
NX70 Processor Specifications
ProcessorUnit
?NX70-CPU70p19.6k words 1 Comm. port
?NX70-CPU70p220k words 2 Comm. ports
Power SupplyUnit
?AC Type1) NX70-POWER1
(110/220V input, free voltage)3.5A at 5V, 0.3A at 24V
2) NX70-POWER2(110/220V input, free voltage)4.0A at 5V
?DC Type1) NX70-PWRDC
(24V dc input)4.0A at 5V
I/O Backplane*
?2-slot type?3-slot type ?5-slot type ?6-slot type ?8-slot type ?10-slot type ?12-slot type
Discrete Unit Analog Unit
?4, 8 channel A/D unit?2, 4 channel D/A unit?4 channel RTD unit?4 channel TC unit
Specialty Unit
?1,2,4 channel HSC unit?4 channel Pulse output moduel?Serial Communication unit?Multi-Wire Link unit?Remote Slave unit?DeviceNet Slave unit?2/4 Axes Position Control unit
?8 points relay unit?16 points I/O unit?32 points I/O unit?8 points input, 8 points
output combo unit?16 points input, 16 points
output combo unit
RS232C/485 with DSUB 9Pin Connector
?????????????????????????? I 7
Features of NX700
1. Correction of program during RUN Program corrections can be done during CPU operationwithout having to stop the system.
2. Embedded PID ProcessorPID 8 control Logic is embedded so that application of manualcontrol environments such as temperature/RUN control ismade exceedingly easy.
3. Embedded clock (RTC : Real Time Clock) functionWork process is programmable by hour and day with theembedded clock.
4. Sufficient program capacity/ back-up function Up to max 20K of words and programs can be stored forperpetuity by providing ROM Pack unit with FLASH back-upmethod.
5. Self Diagnosis Function Equipped with convenient system error and mal-functiondetection with self-diagnosis functions..
6. Diverse I/O and basic special unit support DC24V I/P(16/32/64 points), AC110V I/P, AC220V I/P, RelayO/P, TR O/P(16points/32/64points),SSR O/P, A/D, D/A, RTD,TC, High Speed Counter (1CH, 2CH), CCU+(Comm. leased),SCU(Data Processing Device) can be used.
7. Diverse Peripheral Device Equipped with leased graphic software (WinGPC S/W) forCPU control, checking the CPU status and forced I/O, as wellas I/O monitoring and program download/upload can be doneconveniently.
8. Diverse Communication Function By providing 2 high speed communication ports, linkingcomputers and peripheral devices without separate unitsbecame easier. Also, COM2 port supports user-definedcommunications mode so that the bar code reader, Ac driveand servo can be linked and controlled by externalcommunications. (Binary communication available)
?Control Point is up to 1600 point highspeed processing, for optimal control inthe medium scaled control environments ?High-speed, large capacity data exchange
by direct interface with TOUCH PANNELis enabled by embedding 2 channelcommunication port. ?By adopting the diverse I/O units and
removable terminal blocks,maintenance/repair and design was madeeasier.
NX700 Series Compact Logic Controller
NX700 is a medium-small sized PLC
product intended to provide diverse units,
including such as functions as high speed
processing of user programs, and manual
and network units for more efficient
response to the control environments.
8 I ??????????????????????????
CPU Unit
Motherboard
?3-slot type ?5-slot type ?8-slot type ?10-slot type ?12-slot type
?Combined use forBasic/ Additionalsetup
Special Unit I/O unit
?16 point type ?32 point type ?64 point type
Peripheral Device
?Computer Software - WinGPC S/W ?Computer Interface Cable
?A/D, D/A, RTD, TC ?CCU, SCU unit?Positioning (1, 2, 3, 4 axis)
(Open Collector & LineDrive) ?High Speed Counter (1/ 2CH) ?High Performance High
Speed Counter (4CH) ?Pulse Output unit (4CH) ?Remote I/O SYSTEM ?MW-LINK SYSTEM ?EtherNet SYSTEM ?DeviceNet SYSTEM
System Configuration
?NX-CPU700p20k Step, 0.2? Communication Port2portUse WinGPC S/W
Power Supply Unit
?AC Type1)NX-POWER (AC110/220V)
5V 4A, 24V 0.5A2)NX-PWR220 (AC220V Only)
5V 6A?DC Type
1)NX-PWRDC (DC24V)5V 5A
Program storing, repetitive operation method
1,600 points (2,048 points when Remote I/O is used)
28 kinds
150 kinds
0.2us/step
0.4~ tens of us/step
20K words
R0.0 ~ R127.15 (2048 points, 128 words)
L0.0 ~ L63.15 (1024 points, 64 words)
M0.0 ~ M127.15 (2048 points, 128 words) However, M0.0~ M63.15 can be used as Link Interface
K0.0 ~ K127.15 (2048 points, 128 words)
F0.0 ~ F15.15 (256 points)
256 channel (timer+counter), set value: 0 ~65535
?Timer: 0.01sec.: CH000 ~ CH063 (64 Ch.), 0.1sec.: CH064 ~ CH255 (192Ch.) ?Counter: CH000 ~ CH255 (256 Ch.)W0000 ~ W2047, W3072 ~ W5119 (4096 words)
W2560(=SR000)~W3071(=SR511) (512 words)
Built in(year, month, day, hour, minute, second, week)
RS232C/ RS485, 9600/ 19200/ 38400 bps
RS232C/ RS485, 4800/9600/19200/38400 bps
Supports user defined com. Method (bar code, AC Drive, Servo driver can be linked with
communication) Supports binary communication
SRAM with Battery, and Built-In Flash Memory
Control Method External I/O
Program Capacity
ProcessingSpeed
CommandsBasic Command
Appl. Command
Basic Command
Appl. Command
I/O Interface (R)
Link Interface (L)
Internal Interface(M)
Electrostatic maintenance Interface (K)
Special Interface (F)
Data Register (W)
Special Reg.(W,SR)
COM1
COM2
Timer/ Counter
Interface(TC or TIM)
CPU Type NX-CPU700p
NX700 CPU Specification
Clock Function (RTC)
CommunicationFunction
Program Back Up
Capacityof DataMemory
?Display of slot numbers indicates the number ofI/O and special units mounted ?CPU unit is not necessary when motherboard is
used for extension purpose and thus one moreslot can be used additionally
?????????????????????????? I 9
NX7 Product List
NX7, 28 points base (AC power, DC_16P, RY_12P)
NX7, 28 points base (AC power, DC_16P, TR_12P)
NX7, 48 points base (AC power, DC_28P, RY_20P)
NX7, 48 points base (AC power, DC_28P, TR_20P)
NX7, 28 points base (DC power, DC_16P, RY_12P)
NX7, 28 points base (DC power, DC_16P, TR_12P)
NX7, 48 points base (DC power, DC_28P, RY_20P)
NX7, 48 points base (DC power, DC_28P, TR_20P)
NX7, 14 points base (AC power, DC_8P, RY_6P)
NX7, 14 points base (AC power, DC_8P, TR_6P)
NX7, 14 points base (DC power, DC_8P, RY_6P)
NX7, 14 points base (DC power, DC_8P, TR_6P)
NX7, 20 points base (AC power, DC_12P, RY_8P), 6 analog ( AI_4ch, AO_2Ch)
NX7, 20 points base (AC power, DC_12P, TR_8P), 6 analog ( AI_4ch, AO_2Ch)
NX7, 14 points extension (DC_8P, RY_6P)
NX7, 14 points extension (DC_8P, TR_6P)
NX7, 28 points extension (DC_16P, RY_12P)
NX7, 28 points extension (DC_16P, TR_12P)
Type Catalog number DescriptionsNX7_28ADR
NX7_28ADT
NX7_48ADR
NX7_48ADT
NX7_28DDR
NX7_28DDT
NX7_48DDR
NX7_48DDT
NX7S_14ADR
NX7S_14ADT
NX7S_14DDR
NX7S_14DDT
NX7_20ADR_6A
NX7_20ADT_6A
NX7_14EDR
NX7_14EDT
NX7_28EDR
NX7_28EDT
NX7 Base
Analog
Extension
10 I ??????????????????????????
NX70 Product List
NX70 plus CPU, 0.2us, 9.6K, RS232C/485 1Port
NX70 plus CPU, 0.2us, 20K, 232C/485 2Port, RTC
Power Supply, AC100~220V Input, Out : 5V 3.5A, 24V 0.3A)
Power Supply, AC100~220V Input, 5V 4.0A
Power Supply, DC24V Input, Out : 5V 4.0A
NX70 BASE, I/O 2 Slots
NX70 BASE, I/O 3 Slots
NX70 BASE, I/O 5 Slots
NX70 BASE, I/O 6 Slots
NX70 BASE, I/O 8 Slots
NX70 BASE, I/O 10 Slots
NX70 BASE, I/O 12 Slots
DC12~24V Input Unit, 16Points
DC24V Input Unit, 16Points
DC12~24V Input Unit, 32Points(20pin Connector x 2)
DC24V Input Unit, 32Points(20pin Connector x 2)
110VAC Input Unit, 16Points
220VAC Input Unit, 16Points
I/O Mix 16p Unit, DC24V Input 8p/ Relay Output 8p
I/O Mix 32p Unit, DC24V Input 16p/ TR Output 16p
Relay Output Unit, 8Points(Included ZNR)
Relay Output Unit, 16Points
Relay Output Unit, 16Points(Included ZNR)
TR Output Unit, 16Points
TR Output 32p(Sync Type, NPN), Connector(20p x 2)
TR Output 32P(Source Type, PNP), Connector(20pin x 2)
AC(SSR) Output Unit, 16Points
Dummy Unit (Blank Cover)
NX70 Analog Input, 8Ch, Voltage (?10V,?5V)
NX70 Analog Input, 8Ch, Current, (4~20mA)
NX70 Analog Input, 4Ch, Voltage (?10V,?5V)
NX70 Analog Input, 4Ch, Current, (4~20mA)
NX70 Analog Output, 2Ch, Voltage (?10V,?5V)
NX70 Analog Output, 2Ch, Current, (4~20mA)
NX70 Analog Output, 4Ch, Voltage (?10V,?5V)
NX70 Analog Output, 4Ch, Current, (4~20mA)
RTD Input Unit, 4Ch
Thermocouple Input Unit, 4Ch,
HSC 1CH, 100Kcps, 24Bit
HSC 2CH, 100Kcps, 24Bit
HSC 4CH, 200Kcps, 32bit
Pulse Control Unit, HSC 4Ch, Pulse 4Ch
2 Axes Position Control Unit
4 Axes Position Control Unit
SCU, Serial Comm. Unit (232C/485, 2Ports)
W-LINK Unit
DeviceNet Slave for NX70 series
Computer Communication Unit
Type Catalog number DescriptionsNX70_CPU70p1
NX70_CPU70p2
NX70_POWER1
NX70_POWER2
NX70_PWRDC
NX70_BASE02
NX70_BASE03
NX70_BASE05
NX70_BASE06
NX70_BASE08
NX70_BASE10
NX70_BASE12
NX70_X16D
NX70_X16D1
NX70_X32D
NX70_X32D1
NX70_X16A110
NX70_X16A220
NX70_XY16
NX70_XY32
NX70_Y8R
NX70_Y16R
NX70_Y16RV
NX70_Y16T
NX70_Y32T
NX70_Y32P
NX70_Y16SSR
NX70_DUMMY
NX70_AI8V
NX70_AI8C
NX70_AI4V
NX70_AI4C
NX70_AO2V
NX70_AO2C
NX70_AO4V
NX70_AO4C
NX70_RTD4
NX70_TC4
NX70_HSC1
NX70_HSC2
NX70_HSC4
NX70_PULSE4
NX70_POSI2
NX70_POSI4
NX70_SCU
NX70_WLINK
NX70_DNS
NX70_CCU+
CPU
Power
Base
Input
I/O Combo
Output
Analog
Motion
Communication
?????????????????????????? I 11
NX700 Product List
NX700P CPU UNIT, 20KW, 0.2uS, 2Port, RTC
NX700 AC POWER, 5V 4A, 24V 0.5A
NX700 AC220V POWER, 5V 6A Out,
NX700 DC24V POWER, 5V 5A Out
NX700 Base, I/O 3 Slots,
NX700 Base, I/O 5 Slots,
NX700 Base, I/O 8 Slots,
NX700 Base, I/O 10 Slots,
NX700 Base, I/O 12 Slots,
DC12~24V Input Unit, 16points, Terminal
DC12~24V Input Unit, 32p, Connector (40pin x 1)
DC12~24V Input Unit, 64p, Connector (40pin x 2)
AC110V Input Unit, 16points, Terminal
AC220V Input Unit, 16points, Terminal
Relay Output(AC250V 2A), 16points, Terminal
Relay Output(AC250V 2A), 16p, ZNR, Terminal
Relay Output(AC250V 1A), 32p, ZNR, Connector(40pin x 1)
TR Output(Sync. NPN), 16points, DC24V 0.6A, Terminal
TR Output(Sync. NPN), 32p, DC24V 0.4A, Connector(40pin x 1)
TR Output(Sync. NPN), 64p, DC24V 0.2A, Connector(40pin x 2)
SSR(AC) Output(AC100~220V 0.5A), 16p, Terminal
Analog Input, 8Ch, Voltage(?10V, 0~5V)
Analog Input, 8Ch, Current(?20mA, 4~20mA)
Analog Output, 8Ch, Current(4~20mA)
Analog Output, 8Ch, Voltage(?10V,?5V,0~5V,0~10V)
Analog Output, 4Ch, Voltage(?10V,?5V,0~5V,0~10V)
Analog Output, 4Ch, Current(4~20mA)
RTD Input, 8Ch, Pt100, JPt100,
RTD Input, 4CH, Pt100, JPt100,
Thermocouple Input, 8Ch, Type B/R/S/N/K/E/J/T
Thermocouple Input, 4Ch, Type B/R/S/N/K/E/J/T
NX700 HighSpeed Counter Unit, 1Ch, 24Bit, 100Kcps.
NX700 HighSpeed Counter Unit, 2Ch, 24Bit, 100Kcps.
HSC Unit, 4Ch, 32Bit, 200Kcps. 40pin Connector.
Pulse Out 4Ch 100k/PLS, HSC 4Ch, 200Kcps
NX700 Positioning unit for 1 axes
NX700 Positioning unit for 2 axes
NX700 Positioning unit for 3 axes
NX700 Positioning unit for 4 axes
CCU+(Computer Comm.), RS-232C/485 1Port.
SCU(Serial Comm. Unit), RS232C/485 2Port
MW-LINK Unit(CPU Network), 32 Station, 0.5M,
NX700 Remote Master(Scanner) Unit
Remote Slave Unit
DeviceNet Master(Scanner) Unit
Dummy Unit (Blank Cover)
NX700 Base Extension Cable, 0.8m
NX700 Base Extension Cable, 1.5m
Type Catalog number DescriptionsNX_CPU700P
NX_POWER
NX_PWR220
NX_PWRDC
NX_BASE03
NX_BASE05
NX_BASE08
NX_BASE10
NX_BASE12
NX_X16D
NX_X32D
NX_X64D
NX_X16A110
NX_X16A220
NX_Y16R
NX_Y16RV
NX_Y32RV
NX_Y16T
NX_Y32T
NX_Y64T
NX_Y16SSR
NX_AI8V
NX_AI8C
NX_AO8V
NX_AO8C
NX_AO4V
NX_AO4C
NX_RTD8
NX_RTD4
NX_TC8
NX_TC4
NX_HSC1
NX_HSC2
NX_HSC4
NX_PULSE4
NX_POSI1
NX_POSI2
NX_POSI3
NX_POSI4
NX_CCU+
NX_SCU
NX_MWLINK
NX_MASTER
NX_SLAVE
NX_Device
NX_DUMMY
NX_EXPCBL08
NX_EXPCBL15
CPU
Power
Base
Input
Output
Analog
Motion
Communication
Cover
Cables
12 I ??????????????????????????
NX I/O Series Feature
OEMax provides you with the most optimized I/O solution;Modular, slim type for space-savings and flexible I/Oconfiguration. Enjoy an innovative control solution fromOEMax Controls.
Compatible with a Wide Variety of Control Solutions?PLC interface?PC based solution?HMI Interface
Highly Flexibie I/O Configuration?Supports from1 to 512 I/O points?Digital and analog I/O?Modular (up to 32 units)
Reduced Wiring?Distributed Panel configuration?Short start-up/installation time?Fast replacement?Easy maintenance
Excellent Self-diagnostics?Output protection?UNetwork faults
DeviceNet
64 node Max.
I/O Slave messaging (Group 2 only slave)
Poll command , Bit_strobe command,
Cyclic command , COS command
Max. 32 slot
Input 32bytes/ Output 32bytes
Status Input 1 byte
Max. Discrete I/O : Input 256points / Output 256points
Max. Analog I/O : Input 16channels / Output 16channels
1 green/red Unit Status Indicator
1 green/red Network Status Indicator
1 green/red Expansion Unit Status indicator
1 green Field Power Status indicator
125K bit/s (500m maximum),250K bit/s (250m maximum)
500K bit/s (100m maximum)
Detect Field Power @24Vdc
EtherNet/IP
Limited by Ethernet Specification.
Ethernet/IP, BOOTP, "16 IO message connections,
64 CIP connections, 64 Explicit message connections"
Up to100m from Ethernet Hub/Switch with twisted CAT 3 UTP/STP
Max. 32 slot
Total: Input 256 bytes / Output 256bytes
Max. Discrete I/O : Input 2,048points / Output 2,048points
Max. Analog I/O : Input 128channels / Output 128channels
1 green/red, Unit Status (MOD)
1 green, Network Status (NET)
1 green, Link/Active Status (LINK)
1 green/red Expansion I/O Unit Status (I/O)
1 green, Field Power Status
10/100Mbps, Auto-negotiation, Full duplex
Detect Field Power @24Vdc
Profibus-DP/V1
100 node Max.
Station type: Slave
?Freeze mode, ?Sync,?Fail safe mode
?Redundancy,?FMS support
Max. 32 slot
Total: Input 128 bytes / Output 128 bytes
Max. Discrete I/O:Input 1,024points /Output 1,024points
Max. Analog I/O:Input 64channels /Output 64channels
1 green/red Unit Status Indicator
1 green/red Network Status Indicator
1 green/red Expansion Unit Status indicator
1 green Field Power Status indicator
9.6k ~ 12M (1.2Km ~ 100m)
Detect Field Power @11Vdc
Node Count
Protocol
I/O Data Size
Unit Count
Communication Speed
Indicators
Field Power Monitoring
X X X
NX I/O Adapter Specification
OEMax NXIO Series Global Standard Fieldbus Network Solution
Using distributed I/O with a Global
Standard Network such as DeviceNet and
Profibus offers you access to a wide variety
of open systems for a controller
independent environment.
?????????????????????????? I 13
PROFIBUS-DP/V1 Network Adapter
Modbus TCP/IP(EtherNet) Network Adapter
Modbus RS485 Network Adapter
4 Points Sink Terminal 12V/ 24V DC
4 Points Sink Terminal 48V DC
8 Points Sink Terminal 12V/ 24V DC
16 Points Sink 20P Connector 12V/ 24V DC
4 Points 220V AC (AC 0~40V/ 79V~230V)
4 Points Sink Terminal 24V DC/ 0.5A
4 Points Sink Terminal Diagnostics 24V DC/ 2A
8 Points Sink Terminal 24V DC/ 0.5A
16 Points Sink 20P Connector 24V DC / 0.1A
TRIAC Output 2 Points 12 ~ 125V AC/ 0.5A
4 Channels current Terminal 0~20mA, 14bit
4 Channels current Terminal 4~20mA, 14bit
4 Channels Voltage Terminal 0~5V, 14bit
4 Channels Voltage Terminal 0~10V, 14bit
4 Channels Voltage Terminal -10~10V, 14bit
T/C Input 2 Channels Terminal, B/R/S/N/K/E/J/T 30mV(1uV/bit)
2 Channels Current Terminal 4~20mA, 12bit
2 Channels Voltage Terminal -10~10V, 12bit
High Speed Counter, 1CH, 24V
2 CHANNELS, UART, RS232C COM UNIT
2 CHANNELS, UART, RS485 COM UNIT
Power distributor
NXIO-PA/V1
NXIO-MNA/TCP
NXIO-MNA/485
NXIO-XN4B
NXIO-XN4N
NXIO-XN8B
NXIO-XN16B
NXIO-XA4W
NXIO-YN4K
NXIO-YN4LD
NXIO-YN8K
NXIO-YN16G
NXIO-YT2V
NXIO-AI4AM
NXIO-AI4BM
NXIO-AI4VM
NXIO-AI4KM
NXIO-AI4LM
NXIO-TC2
NXIO-AO2B
NXIO-AO2L
NXIO-HSC1G
NXIO-RS232B
NXIO-RS485B
NXIO-FPI
Processor Units
EtherNet/IP Network Adapter
DeviceNet Network Adapter
Modbus RS232 Network Adapter
CC-LINK Network Adapter
Expansion I/O Digital Input Units-DC Input
4 Points Source Terminal 12V/ 24V DC
4 Points Source Terminal 48V DC
8 Points Source Terminal 12V/ 24V DC
16 Points Source 20P Connector 12V/ 24V DC
Expansion I/O Digital Input Units-AC Input
4 Points 110V AC (AC 0~40V, 80V~140V)
Expansion I/O Digital Output Units-DC Output
4 Points Source Terminal 24V DC/ 0.5A
4 Points Source Terminal Diagnostics 24V DC/ 2A
8 Points Source Terminal 24V DC/ 0.5A
16 Points Source 20P Connector 24V DC / 0.1A
Expansion I/O Units-AC Output
Relay Output 2 Points 230V AC/ 2A
Relay Output 4 Points 230V AC/ 2A
Expansion I/O Units-Analog Input
4 Channels Current Terminal 0~20mA, 12bit
4 Channels Current Terminal 4~20mA, 12bit
4 Channels Voltage Terminal 0~5V, 12bit
4 Channels Voltage Terminal 0~10V, 12bit
4 Channels Voltage Terminal -10~10V, 12bit
RTD Input 2 Channels Terminal, PT100,JPT100 300? (10m?/bit)
Expansion I/O Units-Analog Output
2 Channels Current Terminal 0~20mA, 12bit
2 Channels Voltage Terminal 0~10V, 12bit
2 Channels Voltage Terminal 0~5V, 12bit
Expansion I/O Units-Special Functions
High Speed Counter, 1CH, 5V
1 CHANNELS, UART, RS232C COM UNIT
1 CHANNELS, UART, RS485 COM UNIT
1 CHANNELS, UART, RS422 COM UNIT
Field Power Distributor
Power Supply Unit 24V DC, 10A
END Cap
NXIO-ENA/IP
NXIO-DNA
NXIO-MNA/232
NXIO-CCA
NXIO-XP4B
NXIO-XP4N
NXIO-XP8B
NXIO-XP16B
NXIO-XA4Q
NXIO-YP4K
NXIO-YP4LD
NXIO-YP8K
NXIO-YP16G
NXIO-YR2W
NXIO-YR4W
NXIO-AI4A
NXIO-AI4B
NXIO-AI4V
NXIO-AI4K
NXIO-AI4L
NXIO-RTD2
NXIO-AO2A
NXIO-AO2K
NXIO-AO2V
NXIO-HSC1A
NXIO-RS232A
NXIO-RS485A
NXIO-RS422A
NXIO-PS24DC
NXIO-END
OEMax NXIO Product List
14 I ??????????????????????????
Focus on the state-of-the-art PLC ladder editor style andproductivity, the WinGPC4.0 Ladder Editor is developed tohave more user-friendly interface, and it is easier to learn andoperate.
The new features are:1. More convenient in ladder configuration:
easy to add ladder element, no need to draw rung and branchwire by wire.
2. Simplified drag & drop operation easier for configuration and modification, support Ctrl and SHIFTcombination while dragging.
3. Unlimited Undo/Redo operations
4. Supports F1 ~ F12 function keys and shortcuts for keyboarduser
5. Full Windows Cut/Copy/Paste support
6. Long rungs wrap automatically: easier for logic configurationand modification.
7. Smart error positioningdouble click the error information in Output Window to havecursor jump to the error location.
8. Continuous Zoom function:zoom in and zoom outfunctions provide differentview scale.
Major Benefits of WinGPC4.0 LadderEditor New Features
You don't need the user manual touse WinGPC, just start clicking!
WinGPC 4.0 Software
?Reduce your programming time by usingStandard Windows style Drag & Drop,Cut / Copy / Paste operations.?Support for multiple programming and
monitoring windows reduces debuggingtime.?Correct mistakes quickly by using the
unlimited Undo/Redo function.?Continuous Zoom In/Out with automatic
resizing makes viewing your programeasier.?Reduce training costs and simplify your
life. WinGPC supports all NX PLCs fromthe low cost NX7S to the modularNX70/700 platform.?"WinGPC is free to download with no user
registration or serial numbers. Installationis quick and easy."
OEMax knows well user friendly
programming. Simple, direct operation with
standard MS Windows operation. Fast and
easy debugging and monitoring are what
successful PLC engineers need. You can get
all of this by using WinGPC 4.0
?????????????????????????? I 15
Publication OEMAX NX-BR001A-EN-P 2007. 2 Copyright 2007 Rockwell Automation Korea. All Rights Reserved.