Revised 6/24/2008 FISHER BERKELEY EKTACOM CATALOG REPLACEMENT PARTS AUDAC Factory Direct Parts Source • MMC Series Multiplexed Nurse call • HV-4 Series Tone/Visual Nurse call • HB Audio Series Audio/Visual Nurse call
Revised 6/24/2008
FISHER BERKELEY
EKTACOM
CATALOG REPLACEMENT PARTS
AUDAC Factory Direct Parts Source
• MMC Series Multiplexed Nurse call
• HV-4 Series Tone/Visual Nurse call
• HB Audio Series Audio/Visual Nurse call
INTRODUCTION
The Fisher Berkeley/EKTACOM parts listed in this cata-log are current production items. Additional will be addedat a future date. AUDAC also has an extensive inventoryof parts that are no longer in production. If you have aspecific need please contact us for availability.
AUDAC also offers repair on Fisher Berkeley EKTACOMparts. Repairs are made on parts of recent productionitems.
Ship repairs to:
Attn: Repairs DepartmentAUDAC3095 Kerner Blvd, Suite USan Rafael, CA 94901
A Purchase order must accompany repairs to include Bill& Ship to information.
REPAIR SERVICE
TERMS
AUDAC accepts Visa or Master Card. Terms of Net 30 daysare subject to credit approval. Additional Charges apply toCOD orders. All orders are shipped FOB San Rafael.AUDAC ships UPS Ground unless specified otherwise.
Page 3
NURSE CALL SYSTEM PARTS
AUDAC has more than 30 years experience with installation, troubleshooting and repair.Of Fisher Berkeley EKTACOM Nurse call systems.
In 1999 Fisher Berkeley was acquired by Hill Rom Corporation. Hill Rom was providing replacementparts for the entire Fisher Berkeley product line. All of the Fisher Berkeley inventory of replacementparts and components were relocated to North Carolina to an out-sourced manufacturing company bythe name of Fawn Industries.
In December 2005 there was a catastrophic fire at Fawn’s facility. All of the Fisher Berkeley inventorywas destroyed.After evaluating the start up cost of replacing the inventory a decision was made to drop the productline completely. AUDAC negotiated a deal with Hill Rom to provide replacement parts direct fromAUDAC. We obtained a licensing agreement giving us access to the information necessary to buildreplacement parts to original specifications. So we can continue supporting our customers.
Today AUDAC is manufacturing replacement parts and shipping product internationally to many Fisher Berkeley customers. We havere-established relationships with some of the former Fisher Berkeley Distributors who can offer the parts and on-site local service.We may never be able to replace the entire Fisher Berkeley inventory of parts but are making our best effort to provide the key funda-mental working parts necessary to keep your systems going for years to come. This catalog represents our current product offering. Addi-tional items are continuously added.
Hospital shower stationWater-proof shower station used in shower
and bathrooms.
Staff Assist stationStaff Emergency station used at Patient
headwalls, Exam & Procedure rooms. MODEL# HSE-21
SYSTEM TYPE: MMC SERIES
Model# HSS-21
Code Blue stationCode Blue station used at Patient
headwalls, Exam & Procedure rooms.
MODEL# HCB-21
MMC Replacement batteriesRecommended change at 24 month intervals or erratic
operation can occur.
MODEL# Y00091-00 for HQ-1Model# Y00267-00 for HQ-1B
Page 4
Code Blue station w/clock relaysCode blue station with
additional relay contacts for
starting elapsed timers or
interface to HE-II systems.Model # HCB-21-CLK
Bathroom Push for helpToilet “PUSH FOR HELP” emergency station places a
BATH Call
Model # HTS-21-
Replacement CordPull-cord replacement for HSS-21
Shower station includes cord, red
tassel and plastic relief that mounts
into black car of station. Model # FBB09040-01
Single Patient StationAddressable single bedside station
audio/visual .
Model # HPCB-10
Page 5
Dual Patient StationAddressable dual bed side
station audio/visual.
Model # HPCB-20
Dual Patient Station Side-rail CommunicationBedside station with additional
entertainment circuits to interface
with side rail communications in
Patient bed.
Page 6
Single Patient Station Side-rail CommunicationBedside station with additional entertainment circuits to
interface with side rail communications in Patient bed.
Dome Lens CoverReplacement lens cover for
HDL-10,20,30,40
Model# P00046-05
Model# HPCB-20-COSC
Model # HPCB-10-COSC
Staff StationAddressable staff intercom station
audio/visual. Used in exams,
lounges, locker rooms etc.
Model # HPCS-10
Corridor Dome LightUp to four lamps 24VDC, White, Amber,
Green, Red
(10 White),(20 White/Red)
(30 White, Amber, Red), - (40 White, Amber,
Area Control ModuleProvides address and smartelectronics for stand alone bath/shower stations and other peripherals
Model# HDL-10,HDL-20, HDL-30,HDL-40
Model # HPCB—0
HandsetReplacement handset for MMC
Model # 64259
Page 7
Page 8
Custom ChipUsed in all MMC smart stations.
Model # FBX00175-00
Metal DividersUp to three metal dividers can be
used in the P00046-05 lens cover
Model # M0067-03
Lamps for HDL-40Replacement lamps for MMC/HV-04
series Nurse call system. NOTICE:
Using the in-correct lamp on MMC
series stations can result in damage to
station circuits. Model # L00018-00
MMC-2 FirmwareContact Tech support for available versions for Masters,
Central logics
Page 9
KnobsReplacement red knob for bathroom pull-cord
Model # Y00024-00
System type: Fits all Ektacom SERIES slotted opening.
Model # HTX-1
Momentary Cord-setPatient cord-set with momentary
call button and 1/4” jack.
Model # HTX-7B
Geriatric Cord-setApply light pressure to pad to place
a call.
Dummy PlugPrevents a cord out call from being
placed.
Model # HTX-8 (1/4” Jack versionHTX-58 (15 pin version)
Page 10
Momentary Cord-setCord-set with 15 pin connector for
all MMC Series patient stations
Model # HTX-51
Analog Pillow SpeakerNurse call button, TV channel button,
rotary volume knob, Optional Room/
Read light buttons
Model # HTX-562-NEWModel # HTX-562-LV-NEW “LV” includeslight buttons
System type: MMC SERIES
Digital Pillow SpeakerDigital Pillow speaker with Nurse call
button, TV On/Off, Channel up/down
volume up/down Closed caption.
Compatible with newer digital TV’s
Model # HTX-562-DigitalModel# HTX-562-LV DIGITAL
Geriatric Cord-setSimply apply pressure to pad area
to place a call.
Model # HTX-57B
System type: MMC SERIES
Page 11
Momentary Cord-setCord-set with 8 pin plug.
Model # HTX-11
System type: HB/HV-03 SERIES
Analog Pillow SpeakerNurse call button, TV channel
button, rotary volume knob.
Model # HTX-32-NEW
Digital Pillow SpeakerDigital Pillow speaker with Nurse call
button, TV On/Off, Channel up/down
volume up/down Closed caption.
Compatible with newer digital TV’s
Model # HTX-32-Digital
Geriatric Cord-setSimply apply pressure to pad area to
place a call.
Model # HTX-17B
System type: HB/HV-03 SERIES
Page 12
Station I/O BoardMMC-2 Series Station bus
board. Supports (4) Bus
positions with individual audio/
Amplifier. For each channel.
Model # HPC-CL-SI/O
HPCM-20 Membrane replacementMMC-2 Series master station replacement
membrane adhesive backed
Model # HPCM-20-KIT
System type: MMC SERIES
Peripheral MembranereplacementsPush for Help (HTS-21) S00021-22
Staff Assist (HSE-21) S00021-24
Code Blue (HCB-21) S00021-23
Model # FBS00024-XX
System type: MMCSERIES
Master I/O BoardMMC-2 Series Station Master board.
Supports (4) Master Station positions.
Model # HPC-CL-MI/O
System type: MMC SERIES
Page 13
CPU Board MMCMMC-2 Series Central
Processor board.
Model# PCA HPC-CL-CPU
Master Station MMCMMC-2 Series Nurse
Control Station
Model# HPCM-20
Page 14
New Power Supply
replacement PCB for
use on HQ-1B
Model# FB-D00417
(Refurbished) HQ-1B, or HQ-1Power Supplies. Limited tosupplies on hand
Model# HQ-1BModel# HQ-1
Batteries sold separately
Page 15
HPCM-CPU Master stationCPU Board
Model# HPCM-CPU
Pre-wired Connectors w/6” pigtails
Sold in 10 Packs only:
Model #
B09050-02 2 Pin ConnectorB09050-03 3 Pin ConnectorB09050-04 4 Pin ConnectorB09050-05 5 Pin ConnectorB09050-06 6 Pin ConnectorB09050-08 8 Pin ConnectorB09050-12 12 Pin Connector
Page 16
HPCM-Display Board,Master Station Display
Model# HPCM-DISPLY
HPCM Master station wallplate with pre-wired socket andpigtails
Model# HPCM-CON
Connector tool head and pistolgrip for terminating B09049-XXConnectors.
HPCM-CONN-TOOL
Model # HVB-20
System type: HV-04 SERIES
Dual Patient stationEktacom Tone/visual dual bedside
station.
Model # HSS-7
System type: HV-04 SERIES
Bathroom Pull-Cord stationPull-cord bathroom station with water-
resistant gasket, compatible replacement
for HSS-1
Model # HSE-1
System type: HV-04/HB-2 SERIES
Emergency Push-buttonTone/Visual series push button emergency station with 8 pin MTA
header for plug in replacement. Suitable replacement for HTS-1
Page 17
ANNUNCIATOR PANEL60 LED Room IndicatorsTone/Visual
Model# HVA6004AN
Page 18
Dual Bedside StationIncludes individual call in and
indicator from each bed.
Model # HBB-200B
System type: HB Series
Lamp filtersInstalled over Nurse lamp to provide color lamp.
Specify color when ordering. XXX= RED, AMB
(Amber), GRN (Green)
Model # HDL-B– XXX
System type: All FB Series
Central Logic Flasher ModuleEktacom Tone/Visual Flasher
logic.
Model # HV-CLSystem type: HV-04 SERIES
Single Patient StationEktacom Tone/Visual bedside
station
Model # HVB-10
System type: HV-04 SERIES
Page 19
Dual Patient stationEktacom Audio Visual dual
bedside station. Single call placed
led.
Model # HBB-201B
System type: HB SERIES
Single Patient stationEktacom Audio/Visual Single
bedside station.
Model # HBB-100B
System type: HB SERIES
Emergency Push button stationPush button station w/ pigtail leads.
Model # HTS-101D
System type: HV-03/HBSERIES
Pull-cord stationPull-cord emergency station w/rubber gasket and
pigtails wire leads.
Model # HSS-107D
System type: HV-03/HB Series
Page 20
Bathroom Pull-Cord w/TasselPull-cord replacement for bathroom station
HSS-103C,HSS-107D,HSS-1,HSS-7
Model # D00096-02
System type: HV,HB Series
Patient stationSingle 1/4 jack patient station audio/Visual
for HB-2 System. Limited quantities on hand.
Two gang mounting.
Model # HBB-10System type: HB-2 Series
Model # B09049-12System type: All FB SeriesSOLD IN Package of 10
Connector12 Pin unwired connectors
Requires special tool.
LIMITED WARRANTY
Parts sold by AUDAC are covered by a one year Warranty fordefects in material or workmanship under normal conditions.The one year Warranty period begins from the date the prod-uct was first sold and shipped from AUDAC.
This warranty does not cover any defect, malfunction, or fail-ure to follow instructions listed in the original equipmentmanuals.
AUDAC is not responsible for negligent operation, abuse,misuse, accident, vandalism, fire, flood or moisture damagebeyond the control of AUDAC.
Products with their serial numbers removed or defaced are notcovered by this warranty.
Any and all implied Warranties, including the implied war-ranty of merchantability, are limited to the duration of thisexpress limited Warranty. Neither AUDAC nor the dealer/re-seller who sells AUDAC products are liable for incidental orconsequential damages of any kind.
A Return Authorization number is required on all items re-turned for a warranty repair.
3095 Kerner BlvdSuite USan Rafael, CA 94901WWW. AUDACSYSTEMS.COM
Phone: 415-459-3095Fax: 415-459-5099E-mail: [email protected]