This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
cCSAus Certified to UL StandardsSuitable for damp locationsThe following combinations are ENERGY STAR® Certified:
– LED Series 1: Flood Beam, Standard Housing with Chicago Plenum and Emergency Battery Back-up options using CTR2002 (-PL-P, -CLR-P, -WHT-P), CTR2001-P and CTR2001W-P trims only
– LED Series 1: Wide Beam, Standard Housing with Chicago Plenum and Emergency Battery Back-up options using CTR2002 (-PL-P, -CLR-P, -WHT-P) and CTR2001W-P trims only
– LED Series 2: Flood Beam, Standard Housing with Chicago Plenum and Emergency Battery Back-up options using CTR2002 (-PL-P, -CLR-P, -WHT-P) and CTR2001W-P trims only
– LED Series 3: Flood Beam, Standard Housing with Chicago Plenum and Emergency Battery Back-up options using CTR2002 (-PL-P, -CLR-P, -WHT-P), CTR2001W-P trims only
– LED Series 2 and LED Series 3 Wide Beam are not Certified– Lutron options are not Certified
Conforms to Washington State Energy code (WSEC) for low air infiltration. Tested in accordance with ASTM E283 (2.0 CFM or less).CP Housings are Chicago Plenum CCEA listed
K4SA | 4" LED New Construction Non-IC StopAire Downlight
Options CP3 - Chicago PlenumER4 - Factory Installed 7W/200mA Emergency Battery Backup (Remote Test Switch)
1. TRIAC and ELV dimming for 120V only.2. Lutron Hi-Lume dimming only available in 120V.3. Chicago Plenum option is not available with D3 or D4 dimming. Chicago Plenum option cannot be used with Emergency Battery Backup option.4. Emergency Battery Backup option: 640 Lumen nominal average for either Series 1, 2, or 3
Features• Aluminum housing with galvanized steel mounting frame; requires
minimum 3" clearance around fixture from insulation material. Thermal protection provided in case of improper insulation use.
• Output over-voltage, over-current and short circuit protection• Through-circuit wiring: max: (8) #12 AWG (4 in/4 out). Wiring
should be rated for at least 90°C. Chicago Plenum (CP) option is not approved for through-circuit wiring.
• Engineered optical system consists of a thermo-plastic optical housing, aluminum reflector and highly transmissive diffusion lens
• Light engine consists of a single, high output multi-chip LED array• Excellent fixture to fixture color consistency within a 3-step
MacAdam Ellipse tolerance• Many trim options available to complement any design style
Performance Summary• System provides a smooth uniform beam while eliminating view of
LED array. Two beam distributions are available. Optics are field interchangeable
• All K4SA LED downlights are available for non-dimming and dimming applications; for a list of compatible dimmers, refer to LED Dimming Specification Sheet
• The following combinations are ENERGY STAR® Certified:– LED Series 1: Flood Beam, Standard Housing with Chicago Plenum and
Emergency Battery Back-up options using CTR2002 (-PL-P, -CLR-P, -WHT-P), CTR2001-P and CTR2001W-P trims only
– LED Series 1: Wide Beam, Standard Housing with Chicago Plenum and Emergency Battery Back-up options using CTR2002 (-PL-P, -CLR-P, -WHT-P) and CTR2001W-P trims only
– LED Series 2: Flood Beam, Standard Housing with Chicago Plenum and Emergency Battery Back-up options using CTR2002 (-PL-P, -CLR-P, -WHT-P) and CTR2001W-P trims only
– LED Series 3: Flood Beam, Standard Housing with Chicago Plenum and Emergency Battery Back-up options using CTR2002 (-PL-P, -CLR-P, -WHT-P), CTR2001W-P trims only
– LED Series 2 and LED Series 3 Wide Beam are not Certified– Lutron options are not Certified
• Conforms to Washington State Energy Code (WSEC) for low air infiltration; tested in accordance with ASTM E283 (2.0 CFM or less)
• CP Housings are Chicago Plenum CCEA listed• Assembled in the USA
Warranty• This complete fixture is covered by ConTech’s full five (5) year
replacement guarantee after date of purchase• Emergency Battery option is covered by a one (1) year replacement
All steel construction. (3) heat treated spring steel mounting clips. Black socket aiming bracket with screws (provided in carton).
CTR2005-P*Pin Spot, White1" I.D, 4-7/8" O.D.
All steel construction. Aluminum reflector. (3) heat treated spring steel mounting clips. Black socket aiming bracket with screws (provided in carton).
CTR2003-P*Scoop Wall Wash, White4-7/8" O.D., 1-1/2" x 3-1/2" Aperture
All steel construction. (3) heat treated spring steel mounting clips. Black socket aiming bracket with screws (provided in carton).
Fixture Delivered Lumens: 974.3Total Watts@120V: 19.7Lumens Per Watt: 49.5Center Beam Candle Power: 844Beam Distribution: 63°Spacing Criterion: 0.95Color Rendering Index (CRI)2: 91Color Temperature (CCT)3: 3075KDesigned for 50,000 Hour Lamp Life3
LM-63 Test No. G20070208LM-79 Test No. S20070602
K4SA330KCMVDW/CTR2002-PL-PSpectral Power Distribution Chart4
1. Accuracy of rendering colors 2. Color appearance of light source 3. Dependent on surrounding temperatures 4. Colors present within the light source
CCT SERIES 1 SERIES 2
2700K 0.90 0.57 0.76
3000K 1.0 0.57 0.76
3500K N/A 0.57 0.76
4000K 1.08 0.57 0.76
P3
K4 SERIES* K6 SERIES* Dimming Options MVD Dimming Range
Manufacturer Product Model Light Output
Leviton IllumaTech IPL06-10z 3%-100%
Leviton IllumaTech IPI06-1LZ 17%-100%
Leviton SureSlide R62-6674 17%-100%
Leviton SureSlide R62-6633 >1%-100%
Lutron Skylark NT-600 >1%-100%
Lutron Diva DV600P 1%-100%
Lutron Diva DVLV-600P 3%-100%
Lutron D-600P 3%-100%
Lutron Diva DVCL-153P 2%-100%
Lutron Maestro MACL-153M 3%-100%
Cooper R1061-LA 7%-100%
Cooper Devine DAL06P-C1 >1%-100%
Cooper TAL06P-C1 >1%-100%
Cooper SAL06p >1%-100%
Cooper Decorator DAL06P-C2 >1%-100%
*277V Triac Dimming is not available
• Incandescent 120VAC dimmers adjust the light with “forward phase control”, where the dimmer “chops” the forward part of the AC wave to deliver less or more power to the light source. No neutral wire connection required.
• Electronic vow voltage 120VAC dimmers adjust the light with “reverse phase control,” where the dimmer “chops” the back part of the AC wave to deliver less or more power to the light source. Neutral wire connection required.
• 0-10V DC low voltage dimmers operate using two low voltage dimming wires that are separate from the 120V or 277V AC power. The dimmer sends a variable output voltage to the fixture based upon the dimming level. 10V corresponds to undimmed operation, 5V to 50% and so on. Switching on/off is controlled with the line voltage power (120V or 277V AC) input to the dimmer and then dimming operation is controlled with the 0-10V DC low voltage wiring connection between the dimmer and the LED driver. The control signal runs on two low voltage control wires (color coded violet and gray).
• Lutron HiLume and EcoSystem dirvers provide continuous dimming from 1%-100%. For a complete list of compatible dimmers and controls, please visit www.lutron.com
DIMMING SPECIFICATIONS | K4 and K6 Series
Notes1. Testing was performed with a single fixture connected to dimmer. 2. Testing has been performed on these dimmers, but this does not imply any warranty of compatibility. 3. Dimming performance can be influenced by different loads, as well as variations in dimmer switches within the same model. 4. Dimmer maximum load rating with LED may differ from published traditional source dimmer ratings. Consult manufacturer for maximum dimmer information.5. Consult factory for additional dimming information.