Top Banner
AQUAmax® Sisteme de epurare SBR AQUAmax® PROFESSIONAL XL Bazine din prefabricate Bazine din beton
11

Catalog Date Dimensionare Professional XL

Jan 11, 2016

Download

Documents

AdrianDespa

catalog statii epurare
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Catalog Date Dimensionare Professional XL

AQUAmax® Sisteme de epurare SBR • AQUAmax® PROFESSIONAL XL

• Bazine din prefabricate • Bazine din beton

Page 2: Catalog Date Dimensionare Professional XL

Produsele noastre se afla intr-o continua dezvoltare. Ne rezervam drep- tul la modificari tehnice si constructive. Nu raspundem pentru eventuale erori, omiteri si greseli de tipar. Cu aparitia acestui document, publicatiile anteriore isi pierd valabilitatea! Valabile sunt exclusiv conditiile generale de afacere ale ATB Umwelttechnologien Romania S.R.L. Mai 2009

Page 3: Catalog Date Dimensionare Professional XL

AQUAmax PROFESSIONAL XL1

Componente constructive ale statiei(Preepurare si stocare namol intr-un singur bazin) XL1-100JFI XL1-100JFI XL1-100JFI XL1-100JFI XL1-100JFI XL1-125JFI

PE 60 75 75 100 100 125PreepurareVolum VPT m³ 9,8 12,0 12,4 16,8 15,6 17,1Numarul bazinelor buc. 1,0 1,0 1,0 1,0 1,0 1,0Diametru dPT [m] m 2,5 2,5 2,8 2,8 2,8 2,8Adancime apa hPT [m] m 2,0 2,5 2,0 2,7 2,5 2,8

Bazin de stocare (tampon)Volum VBT [m³] m³ 5,8 7,2 5,9 8,1 7,5 8,3Numarul bazinelor buc. 1,0 1,0 1,0 1,0 1,0 1,0Diametru dBT [m] m 2,0 2,0 2,0 2,0 2,0 2,0Adancime apa hBT [m] m 1,9 2,3 1,9 2,6 2,4 2,6

SBRVolum VSBR [m³] m³ 8,4 10,6 10,6 11,9 13,7 15,3Numarul bazinelor buc. 1,0 1,0 1,0 1,0 1,0 1,0Diametru dSBR [m] m 2,5 2,5 2,8 2,5 2,8 2,8Adancime max. apa hWmax [m] m 1,7 2,2 1,7 2,4 2,2 2,5Adancime min. apa hWmin [m] m 1,1 1,4 1,1 1,4 1,4 1,5Inaltime strat de namol hS [m] m 0,7 0,9 0,7 1,0 0,9 1,0

Bazin intermediar UV (optional)Volum VBT,UV [m³] m³ 3,6 4,5 4,5 6,0 6,0 7,5Numarul bazinelor buc. 1,0 1,0 1,0 1,0 1,0 1,0Diametru dBT,UV [m] m 1,5 2,0 2,0 2,0 2,0 2,0Adancime apa hBT,UV [m] m 2,0 1,4 1,4 1,9 1,9 2,4

Alte dimensiuni constructiveInaltimea de la baza la admisie / evacuare hE/A [m] m 2,0 2,5 2,0 2,7 2,5 2,8Admisia A [m] / Evacuarea E [m] m 0,8 0,8 0,8 0,8 0,8 0,8Inaltimea totala H [m] (placa de la baza rezervor: 20 cm) m 3,0 3,5 3,0 3,7 3,5 3,8

Tipul instalatiei si numarul de persoane deservite

Legende:1. Beschickungspumpe2. Schlammpumpe3. Klarwasserpumpe4. Belüfter

Va rugam sa respectati:Capacele de acoperire SBR trebuie sa aiba un diametru de 800 mm.Capacele de acoperire SBR trebuie sa aiba gauri de aerisire.

AQUAmax PROFESSIONAL XL1

Page 4: Catalog Date Dimensionare Professional XL

AQUAmax PROFESSIONAL XL1

Legende:1. Beschickungspumpe2. Schlammpumpe3. Klarwasserpumpe4. Belüfter

Va rugam sa respectati:Capacele de acoperire SBR trebuie sa aiba un diametru de 800 mm.Capacele de acoperire SBR trebuie sa aiba gauri de aerisire.

Componente constructive ale statiei(Instalatii cu eliminare P; Preepurarea si stocarea namol intr-un singur bazin) XL1-100JFI XL1-100JFI XL1-100JFI

PE 60 75 100Preepurare la instalatii cu eliminare PVolum VPT m³ 11,6 14,6 16,1Numarul bazinelor buc. 1,0 1,0 1,0Diametru dPT [m] m 2,5 2,8 2,8Adancime apa hPT [m] m 2,4 2,4 2,6

Bazin de stocare (tampon)Volum VBT [m³] m³ 6,9 7,0 7,7Numarul bazinelor buc. 1,0 1,0 1,0Diametru dBT [m] m 2,0 2,0 2,0Adancime apa hBT [m] m 2,2 2,2 2,5

SBR la instalatii cu eliminare PVolum VSBR [m³] m³ 10,1 12,7 14,2Numarul bazinelor buc. 1,0 1,0 1,0Diametru dSBR [m] m 2,5 2,8 2,8Adancime max. apa hWmax [m] m 2,1 2,1 2,3Adancime min. apa hWmin [m] m 1,4 1,5 1,5Inaltime strat de namol hS [m] m 0,8 0,8 0,9

Bazin intermediar UV (optional)Volum VBT,UV [m³] m³ 3,6 4,5 6,0Numarul bazinelor buc. 1,0 1,0 1,0Diametru dBT,UV [m] m 1,5 2,0 2,0Adancime apa hBT,UV [m] m 2,0 1,4 1,9

Alte dimensiuni constructiveInaltimea de la baza la admisie / evacuare hE/A [m] m 2,4 2,4 2,6Admisia A [m] / Evacuarea E [m] m 0,8 0,8 0,8Inaltimea totala H [m] (placa de la baza rezervor: 20 cm) m 3,4 3,4 3,6

Tipul instalatiei si numarul de persoane deservite

AQUAmax PROFESSIONAL XL1

Page 5: Catalog Date Dimensionare Professional XL

AQUAmax PROFESSIONAL XL2

Componente constructive ale statiei(Preepurare si stocare namol intr-un singur bazin) XL2-200JFI XL2-200JFI XL2-200JFI XL2-200JFI XL2-200JFI XL2-200JFI XL2-250JFI

PE 125 125 150 150 175 200 250PreepurareVolum VPT m³ 19,9 20,4 24,1 24,8 28,6 32,4 34,7Numarul bazinelor buc. 2,0 2,0 2,0 2,0 2,0 2,0 2,0Diametru dPT [m] m 2,3 2,5 2,5 2,8 2,8 2,8 2,8Adancime apa hPT [m] m 2,4 2,1 2,5 2,0 2,3 2,6 2,8

Bazin de stocare (tampon)Volum VBT [m³] m³ 9,3 9,5 11,3 11,5 13,4 15,3 16,4Numarul bazinelor buc. 1,0 1,0 1,0 1,0 1,0 1,0 1,0Diametru dBT [m] m 2,3 2,5 2,5 2,8 2,8 2,8 2,8Adancime apa hBT [m] m 2,3 1,9 2,3 1,9 2,2 2,5 2,7

SBRVolum VSBR [m³] m³ 8,7 8,7 10,6 10,6 12,4 14,3 14,9Numarul bazinelor buc. 2,0 2,0 2,0 2,0 2,0 2,0 2,0Diametru dSBR [m] m 2,3 2,5 2,5 2,8 2,8 2,8 2,8Adancime max. apa hWmax [m] m 2,1 1,8 2,2 1,7 2,0 2,3 2,4Adancime min. apa hWmin [m] m 1,3 1,1 1,4 1,1 1,3 1,5 1,4Inaltime strat de namol hS [m] m 0,8 0,7 0,9 0,7 0,8 0,9 1,0

Bazin intermediar UV (optional)Volum VBT,UV [m³] m³ 4,4 4,4 5,3 5,3 6,1 7,0 8,8Numarul bazinelor buc. 1,0 1,0 1,0 1,0 1,0 1,0 1,0Diametru dBT,UV [m] m 2,0 2,0 2,0 2,0 2,0 2,0 2,3Adancime apa hBT,UV [m] m 1,4 1,4 1,7 1,7 1,9 2,2 2,1

Alte dimensiuni constructiveInaltimea de la baza la admisie / evacuare hE/A [m] m 2,4 2,1 2,5 2,0 2,3 2,6 2,8Admisia A [m] / Evacuarea E [m] m 0,8 0,8 0,8 0,8 0,8 0,8 0,8Inaltimea totala H [m] (placa de la baza rezervor: 20 cm) m 3,4 3,1 3,5 3,0 3,3 3,6 3,8

Tipul instalatiei si numarul de persoane deservite

Va rugam sa respectati:Capacele de acoperire SBR trebuie sa aiba un diametru de 800 mm.Capacele de acoperire SBR trebuie sa aiba gauri de aerisire.

AQUAmax PROFESSIONAL XL2

Page 6: Catalog Date Dimensionare Professional XL

AQUAmax PROFESSIONAL XL2

Va rugam sa respectati:Capacele de acoperire SBR trebuie sa aiba un diametru de 800 mm.Capacele de acoperire SBR trebuie sa aiba gauri de aerisire.

Componente constructive ale statiei(Instalatii cu eliminare P; Preepurarea si stocarea namol intr-un singur bazin) XL2-200JFI XL2-200JFI XL2-200JFI XL2-200JFI

PE 125 125 150 175Preepurare la instalatii cu eliminare PVolum VPT m³ 25,3 20,8 30,8 32,9Numarul bazinelor buc. 2,0 2,0 2,0 2,0Diametru dPT [m] m 2,5 2,5 2,8 2,8Adancime apa hPT [m] m 2,6 2,1 2,5 2,7

Bazin de stocare (tampon)Volum VBT [m³] m³ 11,9 9,7 14,5 15,5Numarul bazinelor buc. 1,0 1,0 1,0 1,0Diametru dBT [m] m 2,5 2,5 2,8 2,8Adancime apa hBT [m] m 2,4 2,0 2,3 2,5

SBR la instalatii cu eliminare PVolum VSBR [m³] m³ 11,2 11,2 13,5 14,6Numarul bazinelor buc. 2,0 2,0 2,0 2,0Diametru dSBR [m] m 2,5 2,8 2,8 2,8Adancime max. apa hWmax [m] m 2,3 1,8 2,2 2,4Adancime min. apa hWmin [m] m 1,6 1,3 1,6 1,7Inaltime strat de namol hS [m] m 0,9 0,7 0,9 0,9

Bazin intermediar UV (optional)Volum VBT,UV [m³] m³ 4,4 4,4 5,3 6,1Numarul bazinelor buc. 1,0 1,0 1,0 1,0Diametru dBT,UV [m] m 2,0 2,0 2,0 2,0Adancime apa hBT,UV [m] m 1,4 1,4 1,7 1,9

Alte dimensiuni constructiveInaltimea de la baza la admisie / evacuare hE/A [m] m 2,6 2,1 2,5 2,7Admisia A [m] / Evacuarea E [m] m 0,8 0,8 0,8 0,8Inaltimea totala H [m] (placa de la baza rezervor: 20 cm) m 3,6 3,1 3,5 3,7

Tipul instalatiei si numarul de persoane deservite

AQUAmax PROFESSIONAL XL2

Page 7: Catalog Date Dimensionare Professional XL

AQUAmax PROFESSIONAL XL1

AQUAmax PROFESSIONAL XL1 - 75 pana la 125 PE

AQUAmax PROFESSIONAL XL1 - 150 pana la 250 PE

Va rugam sa respectati:Capacele de acoperire SBR trebuie sa aiba un diametru de 800 mm.Capacele de acoperire SBR trebuie sa aiba gauri de aerisire.

AQUAmax PROFESSIONAL XL1

Page 8: Catalog Date Dimensionare Professional XL

AQUAmax PROFESSIONAL XL1

Componente constructive ale statiei(Preepurare si stocare namol intr-un singur bazin) XL1-100JFI XL1-100JFI XL1-100JFI XL1-125JFI XL1-200JFI XL1-200JFI XL1-200JFI XL1-250JFI XL1-250JFI

PE 60 75 100 125 150 175 200 225 250PreepurareaVolum VPT m³ 9,6 10,6 15,7 17,7 24,1 28,3 29,4 30,9 34,2Lungime Preepurare lPT [m] m 2,0 2,0 2,5 2,5 2,5 2,5 2,5 2,5 2,5Latime Preepurare b [m] m 2,0 2,3 2,6 2,8 4,0 4,5 5,0 5,0 5,0Adancime apa hPT [m] m 2,4 2,3 2,4 2,5 2,4 2,5 2,4 2,5 2,7

Bazin de stocare (tampon)Volum VBT [m³] m³ 6,7 7,4 8,9 13,3 18,1 21,3 22,0 23,2 25,9Lungime Stocare lBT [m] m 1,5 1,5 1,5 2,0 2,0 2,0 2,0 2,0 2,0Latime Stocare b [m] m 2,0 2,3 2,6 2,8 4,0 4,5 5,0 5,0 5,0Adancime apa hBT [m] m 2,2 2,1 2,3 2,4 2,3 2,4 2,2 2,3 2,6

SBRVolum VSBR [m³] m³ 8,4 10,6 14,3 17,5 21,1 24,9 28,7 32,6 36,6Lungime bazin SBR lSBR [m] m 2,0 2,3 2,6 2,8 2,5 2,5 2,8 3,0 3,0Latime bazin SBR b [m] m 2,0 2,3 2,6 2,8 4,0 4,5 5,0 5,0 5,0Adancime max. apa hWmax [m] m 2,1 2,0 2,1 2,2 2,1 2,2 2,1 2,2 2,4Adancime min. apa hWmin [m] m 1,3 1,3 1,4 1,4 1,4 1,4 1,3 1,4 1,6Inaltime strat de namol hS [m] m 0,8 0,8 0,8 0,9 0,8 0,9 0,8 0,9 1,0

Bazin intermediar UV (optional)Volum VBT,UV [m³] m³ 4,8 5,3 7,5 8,5 9,7 11,3 14,1 14,8 20,5Lungime bazin lBT,UV [m] m 1,0 1,0 1,2 1,2 1,0 1,0 1,2 1,2 1,5Latime bazin b [m] m 2,0 2,3 2,6 2,8 4,0 4,5 5,0 5,0 5,0Adancime apa hBT,UV [m] m 2,1 2,0 2,1 2,2 2,1 2,2 2,1 2,2 2,4

Alte dimensiuni constructiveInaltimea de la baza la admisie / evacuare hE/A [m] m 2,4 2,3 2,4 2,5 2,4 2,5 2,4 2,5 2,7Admisia A [m] / Evacuarea E [m] m 0,8 0,8 0,8 0,8 0,8 0,8 0,8 0,8 0,8Inaltimea totala H [m] (placa de la baza rezervor: 20 cm) m 3,4 3,3 3,4 3,5 3,4 3,5 3,4 3,3 3,5

Componente constructive ale statiei(Instalatii cu eliminare P; Preepurarea si stocarea namol intr-un singur bazin) XL1-100JFI XL1-100JFI XL1-100JFI XL1-125JFI XL1-200JFI XL1-200JFI XL1-200JFI XL1-250JFI

PE 60 75 100 125 150 175 200 225Preepurarea la instalatii cu eliminare PVolum VPT m³ 12,2 15,4 17,5 23,2 26,2 28,4 32,6 35,5Lungime Preepurare lPT [m] m 2,0 2,5 2,5 3,0 2,5 2,5 2,5 2,5Latime Preepurare b [m] m 2,5 2,5 2,8 3,0 4,5 4,5 5,0 5,0Adancime apa hPT [m] m 2,4 2,5 2,5 2,6 2,3 2,5 2,6 2,8

Bazin de stocare (tampon)Volum VBT [m³] m³ 5,7 8,7 9,9 10,9 14,7 16,1 18,4 20,2Lungime Stocare lBT [m] m 1,0 1,5 1,5 1,5 1,5 1,5 1,5 1,5Latime Stocare b [m] m 2,5 2,5 2,8 3,0 4,5 4,5 5,0 5,0Adancime apa hBT [m] m 2,3 2,3 2,4 2,4 2,2 2,4 2,5 2,7

SBR la instalatii cu eliminare PVolum VSBR [m³] m³ 10,7 13,5 17,3 20,5 25,5 28,7 33,1 36,6Lungime bazin SBR lSBR [m] m 2,0 2,5 2,8 3,0 2,8 3,0 3,0 3,0Latime bazin SBR b [m] m 2,5 2,5 2,8 3,0 4,5 4,5 5,0 5,0Adancime max. apa hWmax [m] m 2,1 2,2 2,2 2,3 2,0 2,1 2,2 2,4Adancime min. apa hWmin [m] m 1,5 1,6 1,6 1,6 1,4 1,5 1,5 1,7Inaltime strat de namol hS [m] m 0,9 0,9 0,9 0,9 0,8 0,9 0,9 1,0

Bazin interemediar UV (optional)Volum VBT,UV [m³] m³ 6,1 6,2 7,0 7,7 10,5 11,4 13,0 14,2Lungime bazin lBT,UV [m] m 1,0 1,0 1,0 1,0 1,0 1,0 1,0 1,0Latime bazin b [m] m 2,5 2,5 2,8 3,0 4,5 4,5 5,0 5,0Adancime apa hBT,UV [m] m 2,1 2,2 2,2 2,3 2,0 2,1 2,2 2,4

Alte dimensiuni constructiveInaltimea de la baza la admisie / evacuare hE/A [m] m 2,4 2,5 2,5 2,6 2,3 2,5 2,6 2,8Admisia A [m] / Evacuarea E [m] m 0,8 0,8 0,8 0,8 0,8 0,8 0,8 0,8Inaltimea totala H [m] (placa de la baza rezervor: 20 cm) m 3,4 3,5 3,5 3,6 3,3 3,5 3,6 3,8

Tipul instalatiei si numarul de persoane deservite

Tipul instalatiei si numarul de persoane deservite

AQUAmax PROFESSIONAL XL1

Page 9: Catalog Date Dimensionare Professional XL

AQUAmax PROFESSIONAL XL2

Componente constructive ale statiei(Preepurare si stocare namol intr-un singur bazin) XL2-400JFI XL2-400JFI XL2-400JFI XL2-500JFI XL2-500JFI

PE 300 350 400 450 500PreepurareaVolum VPT m³ 44,1 52,5 57,1 64,1 71,3Lungime Preepurare lPT [m] m 3,5 4,0 4,0 4,0 4,0Latime Preepurare b [m] m 5,2 5,2 5,8 6,2 6,6Adancime apa hPT [m] m 2,4 2,5 2,5 2,6 2,7

Bazin de stocare (tampon)Volum VBT [m³] m³ 23,6 24,7 33,5 37,8 42,1Lungime Stocare lBT [m] m 2,0 2,0 2,5 2,5 2,5Latime Stocare b [m] m 5,2 5,2 5,8 6,2 6,6Adancime apa hBT [m] m 2,3 2,4 2,3 2,4 2,6

SBRVolum VSBR [m³] m³ 21,2 25,0 28,9 32,8 36,8Latime SBR b1 / b2 [m] m 2,5 2,5 2,8 3,0 3,2Lungime SBR lSBR [m] m 4,0 4,5 5,0 5,0 5,0Adancime max. apa hWmax [m] m 2,1 2,2 2,1 2,2 2,3Adancime min. apa hWmin [m] m 1,4 1,4 1,3 1,4 1,5Inaltime strat de namol hS [m] m 0,8 0,9 0,8 0,9 0,9

Bazin intermediar UV (optional)Volum VBT,UV [m³] m³ 22,7 23,6 25,7 28,9 32,1Lungime bazin lBT,UV [m] m 1,8 1,8 1,8 1,8 1,8Latime bazin b [m] m 5,2 5,2 5,8 6,2 6,6Adancime apa hBT,UV [m] m 2,1 2,2 2,1 2,2 2,3

Alte dimensiuni constructiveInaltimea de la baza la admisie / evacuare hE/A [m] m 2,4 2,5 2,5 2,6 2,7Admisia A [m] / Evacuarea E [m] m 0,8 0,8 0,8 0,8 0,8Inaltimea totala H [m] (placa de la baza rezervor: 20 cm) m 3,2 3,3 3,3 3,4 3,5

Tipul instalatiei si numarul de persoane deservite

Va rugam sa respectati:Capacele de acoperire SBR trebuie sa aiba un diametru de 800 mm.Capacele de acoperire SBR trebuie sa aiba gauri de aerisire.

AQUAmax PROFESSIONAL XL2

Page 10: Catalog Date Dimensionare Professional XL

AQUAmax PROFESSIONAL XL2

Va rugam sa respectati:Capacele de acoperire SBR trebuie sa aiba un diametru de 800 mm.Capacele de acoperire SBR trebuie sa aiba gauri de aerisire.

Componente constructive ale statiei(Instalatii cu eliminare P; Preepurarea si stocarea namol intr-un singur bazin) XL2-400JFI XL2-400JFI XL2-400JFI XL2-500JFI XL2-500JFI

PE 300 350 400 450 500Preepurarea la instalatii cu eliminare PVolum VPT m³ 49,4 60,4 62,5 66,5 74,6Lungime Preepurare lPT [m] m 3,5 4,0 4,0 4,0 4,0Latime Preepurare b [m] m 5,8 6,2 6,2 6,2 7,2Adancime apa hPT [m] m 2,4 2,4 2,5 2,7 2,6

Bazin de stocare (tampon)Volum VBT [m³] m³ 23,8 25,5 29,4 31,4 35,2Lungime Stocare lBT [m] m 1,8 1,8 2,0 2,0 2,0Latime Stocare b [m] m 5,8 6,2 6,2 6,2 7,2Adancime apa hBT [m] m 2,3 2,3 2,4 2,5 2,4

SBR la instalatii cu eliminare PVolum VSBR [m³] m³ 25,6 28,8 33,3 35,7 40,1Latime SBR b1 / b2 [m] m 2,8 3,0 3,0 3,0 3,5Lungime SBR lSBR [m] m 4,5 4,5 5,0 5,0 5,0Adancime max. apa hWmax [m] m 2,0 2,1 2,2 2,4 2,3Adancime min. apa hWmin [m] m 1,4 1,5 1,6 1,6 1,6Inaltime strat de namol hS [m] m 0,8 0,9 0,9 1,0 0,9

Bazin interemediar UV (optional)Volum VBT,UV [m³] m³ 25,4 27,2 28,1 29,9 33,6Lungime bazin lBT,UV [m] m 1,8 1,8 1,8 1,8 1,8Latime bazin b [m] m 5,8 6,2 6,2 6,2 7,2Adancime apa hBT,UV [m] m 2,0 2,1 2,2 2,4 2,3

Alte dimensiuni constructiveInaltimea de la baza la admisie / evacuare hE/A [m] m 2,4 2,4 2,5 2,7 2,6Admisia A [m] / Evacuarea E [m] m 0,8 0,8 0,8 0,8 0,8Inaltimea totala H [m] (placa de la baza rezervor: 20 cm) m 3,2 3,2 3,3 3,5 3,4

Tipul instalatiei si numarul de persoane deservite