The Complete Line of Pre-Insulated Pipe Supports & Thermal Shields PRE-INSULATED PIPE SUPPORTS 200 CAMPUS DRIVE, R.R. 30 MOUNT HOLLY, NEW JERSEY 08060 (609) 261-5353 FAX: (609) 261-3249 8411 OLD MARLBORO PIKE UPPER MARLBORO, MARYLAND 20772 (301) 568-8805 FAX: (301) 967-1456 WWW.NATIONALPIPEHANGER.COM CATALOG 2013 Made in the USA
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
The Complete Lineof
Pre-Insulated Pipe Supports & Thermal Shields
PRE-INSULATED PIPE SUPPORTS
200 CAMPUS DRIVE, R.R. 30MOUNT HOLLY, NEW JERSEY 08060
(609) 261-5353
FAX: (609) 261-3249
8411 OLD MARLBORO PIKEUPPER MARLBORO, MARYLAND 20772
(301) 568-8805
FAX: (301) 967-1456
WWW.NATIONALPIPEHANGER.COM
CATALOG 2013
Made in the USA
INTRODUCTION
National Pipe Hanger Corporation is proud to present our new Pre-Insulated PipeSupport Catalog containing a complete and versatile line of pre-insulated pipesupports and thermal shields which have been selected to accommodate pipesupport requirements in the commercial and industrial piping fields. This selectionresults from nearly three decades of concentrated and direct exposure to the pip-ing industry, from the design engineer’s selection to the piping contractor’s instal-lation efforts. This is where needs are discovered and where products andservices are genuinely tested. In this area our experiences are unequalled.
A constant awareness of our customers' requirements and efforts is the founda-tion in the development of our manufacturing skills. All National Pipe Hanger Cor-poration products are carefully manufactured to meet the highest standards in theindustry. National Pipe Hanger Corporation is a participating member of the Man-ufactures Standardization Society (MSS).
To complement National Pipe Hanger Corporation’s line of pre-insulated pipe sup-ports, we have added thermal shields manufactured by Value Engineered ProductsIncorporated. Value Engineered Products Incorporated has been in business fortwenty years and they are specified as a thermal shield supplier by most engi-neering firms throughout the United States of America.
Contact National Pipe Hanger Corporation for special pre-insulated pipe supportrequirements including: other pipe sizes and types, insulation thickness, insulationmaterials, slide materials, dimensional requirements, installation methods, fin-ishes, etc. Our people are equipped to respond quickly to your product and serv-ice needs on both standards items and specialized fabrications. Visit our websitefor additional information on pre-insulated pipe supports such as: submittalsheets, installation instructions, competitor model number cross-references, etc.
All units used in this catalog are inch-pound unless otherwise noted. Additionalinformation provided in the end of this catalog can aid the user in: estimating pipesupport loads, determining pipe support spacing, selecting thermal conductivitiesat other operating temperatures, selecting the correct size pipe support for ther-mal shields, and determining the outside diameter of adjoining insulation.
1
GENERAL SELECTION
AXIAL TRAVEL = ± 11/2” AXIAL TRAVEL = ± 41/2”
AXIAL TRAVEL = ± 11/2” AXIAL TRAVEL = ± 41/2”
LAT
ER
AL
LOA
D =
LIG
HT
DU
TY
LAT
ER
AL
LOA
D =
HE
AV
Y D
UT
YLA
TE
RA
L T
RA
VE
L =
± 1 / 2
”LA
TE
RA
L T
RA
VE
L ≥
±11 /2
”
2
NS10 NS20
NS50 NS60
NG30 NG40
NG70 NG80
PRE-INSULATED PIPE SLIDES
PRE-INSULATED PIPE GUIDES
PRE-INSULATED PIPE ANCHOR
3
GENERAL SELECTION
VERTICAL LOAD = LIGHT DUTY VERTICAL LOAD = HEAVY DUTY
SIN
GLE
RO
DT
WO
RO
D
NC30 - NC33NC10
NH40 NH60
PRE-INSULATED PIPE CLAMPS AND HANGERS
FOR AXIAL & VERTICAL LOADS
NA40
PRE-INSULATED STRUT CLAMPS
4
GENERAL SELECTION
HOLDDOWN STRUT CLAMP GUIDED STRUT CLAMP
NC70 NC80
PRE-INSULATED PIPE RISER CLAMPS
FOR DOWNWARD RISER LOADS FOR UPWARD & DOWNWARD RISER LOADS
NR10 NR20
WIT
H T
OP
PR
OT
EC
TIO
N S
HIE
LDW
ITH
OU
T T
OP
PR
OT
EC
TIO
N S
HIE
LD
THERMAL SHIELDS
VALUE ENGINEERED PRODUCTS, INC.
PRO-SHIELD N.T.
PRO-SHIELD CHILL-SHIELD
MAXSPAN R.H.
MAXSPAN
QUIK-SHIELD
VERTICAL LOAD = LIGHT DUTY VERTICAL LOAD = HEAVY DUTY
For Use: In Clevis Hanger On Trapeze
For Use: In Clevis Hanger On Trapeze
For Use: In Clevis Hanger In Two-Bolt Clamp
For Use: In Clevis HangerOn Trapeze
For Use: In Clevis Hanger On Trapeze
For Use: On Roller Support On Flat Surface
5
GENERAL SELECTION
± 11/2” Axial Movement, ± 1/2” Lateral Movement
Applications:
• Allows moderate axial travel and smalllateral travel while providing vertical support
• Designed for use on:Chilled Water Hot Water Steam
• Installation: welded to flat steel surface• Temperature Range: +20°F to +1200°F• Axial Travel: ± 11/2”• Lateral Travel: ± 1/2”
Features:
• Eliminates welding to pipe• Provides continuous vapor barrier• Insulation extends 3” beyond shield• Structural insulation for load transfer• Stainless steel to UHMW polyethylene slide• Static Coefficient of Friction = 0.15• ASTM E-84 Flame Spread/Smoke Developed: 10/5• Thermal Conductivity
0.61 Btu•in/(hr•ft2•°F) @ 200°F• Insulation chemically bonded• B.O.P. to T.O.S. matched to NS and NG models• Four thrust plates shipped loose for field welding
Material Data:
Insulation: Calcium Silicate meeting ASTM C-585 andC-656 Type II Grade 6900 psi, 28 pcf
Base/Clamp: ASTM A-36 Carbon SteelFasteners: ASTM A-307 Electro-Galv. PlatedShield: ASTM A-653 G-90, 18 ga Galv. SteelVapor Barrier: ASTM E-96 All Service JacketFinish: Painted Red Shop Primer
Ordering: Fig. NC80 - (Pipe Size) x (Insulation Thickness)
FIG. NC80
25
For Use on Strut, Laterally Guided
NATIONAL PIPE HANGER CORPORATION
PRE-INSULATED GUIDED STRUT CLAMP
PRO-SHIELD
Description / Features Pro-Shields are 360° thermal hanger shields designed to meet the broadest range of pipe support applications. They providea continuous section of insulation and vapor barrier through a wide variety of pipe hangers for piping systems operating between +20°F and +1200°F. The insulation and vapor barrier extend beyond the galvanized steel shield for a neat, vapor-tight joint with the adjoining insulation. Pro-Shields are suitable for use in any type of clamp as well as in band-type hangers and on flatsurfaces. To assure proper support in all situations, high density 450 psi inserts are installed in units for 10” pipe with 1” insulation thickness and in all units for 12” pipe and larger. Pro-Shields meet the MSS standard for Type 40 shields per MSS SP-58, Para-graph 7.6.
Applications• For indoor use on clamping support systems, flat surfaces, clevis or other band-type hangers (see WeatherShield
Upgrade submittal for outdoor applications).• Pipe sizes 16” and larger in clevis or two bolt hangers only.• Chilled to steam piping and dual temperature lines.• Hanger spans per MSS SP-58 Table A3.• Available for pipe 1/2” through 24”, insulation thickness 1/2” through 4”.
Materials / Construction• 100 psi Calcium silicate meeting ASTM C-533 Type I, C-585, C-795, E-84 Flame Spread/Smoke Developed: 0/0,
Thermal Conductivity = 0.41 Btu•in/(hr•ft2•°F) @ 200°F.• Adhesive complying with NFPA 90-A, ASTM E-84 Flame Spread/Smoke Developed: 10/0.• G-90 Galvanized steel shield, small check per ASTM A-653 (replaces A-527).• Vapor barrier of all service jacket meeting ASTM D-774, D-828 and E-84 Flame Spread/Smoke Developed: 5/5.• Structural insert (12" pipe and larger) minimum 450 psi calcium silicate meeting ASTM C-656 Type II Grade 5,
C-795 and E-84 Flame Spread/Smoke Developed: 0/0.• All units and components are asbestos free and 100% made and assembled in the U.S.A.
PIPE SIZE 1/2” TO 11/2” 2” TO 5” 6” TO 8” 10” TO 12” 14” TO 24”INSULATION LENGTH - in. 6 6 9 9 12
Description / FeaturesPro-Shield N.T. units provide a continuous section of insulation and vapor barrier through a wide variety of pipe hangers for piping systems operating between +20°F and +1200°F. The Pro-Shield N.T. is designed for use in band-type hangers and on flat surfaces. The insulation and vapor barrier extend beyond the galvanized steel shield for a neat, vapor-tight joint with the adjoining insulation. Pro-Shield N.T. meets the MSS standard for Type 40 shields per MSS SP-58, Paragraph 7.6. To assureproper support in all situations, high density 450 psi inserts are installed in units for 10” pipe with 1” insulation thickness and inall units for 12” pipe and larger.
Applications• For indoor use on flat surfaces, clevis or other band-type hangers (see WeatherShield Upgrade submittal for
outdoor applications).• Pipe sizes 16” and larger in clevis hangers only. • Chilled to steam piping and dual temperature lines.• Hanger spans per MSS SP-58 Table A3.• Available for pipe 1/2” through 24”, insulation thickness 1/2” through 4”.
Materials / Construction• 100 psi Calcium silicate meeting ASTM C-533 Type I, C-585, C-795, E-84 Flame Spread/Smoke Developed: 0/0,
Thermal Conductivity = 0.41 Btu•in/(hr•ft2•°F) @ 200°F.• Adhesive complying with NFPA 90-A, ASTM E-84 Flame Spread/Smoke Developed: 10/0.• G-90 Galvanized steel shield, small check per ASTM A-635 (replaces A-527).• Vapor barrier of all service jacket meeting ASTM D-774, D-828 and E-84 Flame Spread/Smoke Developed: 5/5.• Structural insert (12" pipe and larger) minimum 450 psi calcium silicate meeting ASTM C-656 Type II Grade 5,
C-795 and E-84 Flame Spread/Smoke Developed: 0/0.• All units and components are asbestos free and 100% made and assembled in the U.S.A.
PIPE SIZE 1/2” TO 11/2” 2” TO 5” 6” TO 8” 10” TO 12” 14” TO 24”INSULATION LENGTH - in. 6 6 9 9 12
Description / FeaturesQuik-Shields are economically priced 180° thermal hanger shields providing a continuous section of insulation and vapor barrier through a variety of pipe hangers. The vapor barrier jacket extends beyond the galvanized steel shield and beyond the insulation insert for a neat, vapor-tight fit with both the adjoining and the field-applied top insulation. To assure proper support in all situations, high density 450 psi structural inserts are installed in units for 10" pipe with 1" insulation thickness and in all unitsfor 12" pipe and larger.
Applications• For indoor use on flat surfaces, clevis or other band-type hangers. • Pipe sizes 16” and larger in clevis hangers only.• Chilled to steam piping and dual temperature lines.• Hanger spans per MSS SP-58 Table A3.• Available for pipe 1/2” through 24”, insulation thickness 1/2” through 4”.
Materials / Construction• 100 psi Calcium silicate meeting ASTM C-533 Type I, C-585, C-795, E-84 Flame Spread/Smoke Developed: 0/0,
Thermal Conductivity = 0.41 Btu•in/(hr•ft2•°F) @ 200°F.• Adhesive complying with NFPA 90-A, ASTM E-84 Flame Spread/Smoke Developed: 10/0.• G-90 Galvanized steel shield, small check per ASTM A-653 (replaces A-527).• Vapor barrier of all service jacket meeting ASTM D-774, D-828 and E-84 Flame Spread/Smoke Developed: 5/5.• Structural insert (12" pipe and larger) minimum 450 psi calcium silicate meeting ASTM C-656 Type II Grade 5,
C-795 and E-84 Flame Spread/Smoke Developed: 0/0.• All units and components are asbestos free and 100% made and assembled in the U.S.A.
PIPE SIZE 1/2” TO 11/2” 2” TO 5” 6” TO 8” 10” TO 12” 14” TO 24”INSULATION LENGTH - in. 6 6 9 9 12
Description / Features Chill-Shields are 360° thermal hanger shields designed to meet a broad range of pipe support applications on low temperaturelines. They provide a continuous section of insulation and vapor barrier, and are designed for piping systems operating between -250°F and +225°F. The insulation and vapor barrier extend beyond the galvanized steel shield for a neat, vapor-tight joint withthe adjoining insulation. Chill-Shields are suitable for use in any type of clamp as well as in band-type hangers. High compres-sive strength polyisocyanurate inserts and heavy gauge steel shields ensure proper pipe support. These cost effective designsmeet the requirements of either pipe or tube systems.
Applications• For indoor use on clamping support systems, clevis or other band-type hangers. • Chilled piping to domestic hot water. • Hanger spans per MSS SP-58 Table A3 (not suitable for extended hanger spans).• Available for pipe 1/2” through 24”, insulation thickness 1/2” through 4”.
Materials / Construction• Polyisocyanurate meeting ASTM C-591 Type IV Grade 2 (24 psi, 2 pcf), Type V Grade 2 (80 psi, 4 pcf),
Type VI Grade 2 (130 psi, 6 pcf), C-203, C-518, C-585, C-795, D-1621, D-1622, D-1623 andE-84 Flame Spread/Smoke Developed: 25/450,Thermal Conductivity = 0.19 to 0.20 Btu•in/(hr•ft2•°F) @ 75°F.
• 375 psi Polyurethane high compressive insert, standard for 14” pipe and larger, meeting ASTM C-585 and C-795• 360° Non-reactive vapor barrier jacket meeting ASTM D-774, D-828 and E-84 Flame Spread/Smoke Developed: 5/5.• Adhesive complying with NFPA 90-A and ASTM E-84 Flame Spread/Smoke Developed: 10/0.• G-90 Galvanized steel shield, small check per ASTM A-653 (replaces A-527).• All units and components are asbestos free and 100% made and assembled in the U.S.A.
PIPE SIZE 1/2” TO 11/2” 2” TO 4” 5” TO 6” 8” 10” TO 24”INSULATION LENGTH - in. 6 6 9 9 12
Description / FeaturesMaxSpan thermal hanger shield is specifically designed to provide a superior safety margin when supporting pipe with hangerspans up to the maximum allowed in Table 4 of MSS SP-58 in clevis or clamp hangers. These 360° thermal hanger shields pro-vide a continuous section of insulation and vapor barrier through the hanger and can be used on piping systems operating be-tween +20°F and +1200°F. The insulation and vapor barrier extend beyond the galvanized steel shield for a neat, vapor-tight joint with the adjoining insulation. To achieve the protection required by long hanger spans, the MaxSpan thermal hanger shieldsutilize heavier gauge shields, and 900 psi structural inserts (10” pipe and larger). The MaxSpan meets or exceeds the MSS standard for Type 40 shields per MSS SP 58, Paragraph 7.6.
Applications• For indoor use on all band and clamping hanger systems (see WeatherShield Upgrade submittal for outdoor
applications).• Chilled to steam piping and dual temperature lines.• Hanger spans per MSS SP-58 Table 4 in clevis or two-bolt clamp hangers.• Available for pipe 4” through 24”, insulation thickness 1/2” through 4”.
Materials / Construction• 100 psi Calcium silicate meeting ASTM C-533 Type I, C-585, C-795, E-84 Flame Spread/Smoke Developed: 0/0,
Thermal Conductivity = 0.41 Btu•in/(hr•ft2•°F) @ 200°F.• Adhesive complying to NFPA 90-A and ASTM E-84 Flame Spread/Smoke Developed: 10/0.• G-90 Galvanized steel shield, small check per ASTM A-653 (replaces A-527).• Vapor barrier of all service jacket meeting ASTM D-774, D-828 and E-84, Flame Spread/Smoke Developed: 5/5.• Structural insert (10” pipe and larger) of 900 psi calcium silicate per ASTM C-656 Type II Grade 6.• All units and components are asbestos free and 100% made and assembled in the U.S.A.
PIPE SIZE 1/2” TO 11/2” 2” TO 3” 4” TO 8” 10” TO 12” 14” TO 24”INSULATION LENGTH - in. See Pro-Shield 9 9 12 14
SHIELD LENGTH - in. See Pro-Shield 6 6 9 12SHIELD GAUGE See Pro-Shield 16 14 14 12
Description / FeaturesThe MaxSpan R.H. thermal hanger shield is specifically designed to provide a superior safety margin for pipe mounted on piperollers, flat surfaces or with supports where point loading may be a concern. These rugged units allow hanger spans up to themaximum allowed in Table 4 of MSS SP-58. They are appropriate for either hot or cold piping systems. The insulation andvapor barrier extend beyond the galvanized steel shield for a neat, vapor-tight joint with the adjoining insulation. Units for pipe4” and larger include a wear/weight distribution plate of carbon steel (primer painted). Additionally, a segment of ultra high density, 900 psi calcium silicate is fabricated into units for 10” pipe size and larger. The MaxSpan R.H. meets or exceeds theMSS standard for Type 40 shields per MSS SP 58, Paragraph 7.6.
Applications• For indoor use on all roller hanger systems and flat surfaces (see WeatherShield Upgrade submittal for outdoor
applications).• Chilled to steam piping and dual temperature lines.• Hanger spans per MSS SP-58 Table 4.• Available for pipes 1/2” through 24”, insulation thickness 1/2” through 4”.
Thermal Conductivity = 0.41 Btu•in/(hr•ft2•°F) @ 200°F.• G-90 Galvanized steel shield, small check per ASTM A-623 (replaces A-527).• Wear/weight distribution plate - carbon steel meeting ASTM A-36.• Vapor barrier of all service jacket meeting ASTM D-774, D-828 and E-84.• Structural insert (10” pipe and larger) of 900 psi calcium silicate per ASTM C-656 Type II Grade 6.• All units and components are asbestos free and 100% made and assembled in the U.S.A.
PIPE SIZE 1/2” TO 11/2” 2” TO 3” 4” TO 8” 10” TO 12” 14” TO 24”INSULATION LENGTH - in. See Pro-Shield 9 9 12 14
SHIELD LENGTH - in. See Pro-Shield 6 6 9 12SHIELD GAUGE See Pro-Shield 16 14 14 12
PLATE THK. x LENGTH - in. x in. N/A N/A 1/8 x 6 1/4 x 6 1/4 x 10COMPRESSIVE STRENGTH - psi See Pro-Shield 100 100 100 / 900 100 / 900
Description / FeaturesWeatherShield modifications are appropriate for hostile environment or outdoor applications. The calcium silicate insulation istreated with a water-resistant compound to provide additional protection from moisture. The WeatherShield is constructed withthe specified jacketing material laminated between the steel protection shield and the all service vapor barrier jacket. WeatherShield modifications may be specified for all Pre-Insulated Pipe Supports and Pro-Shield, Pro-Shield N.T., MaxSpanand MaxSpan R.H. Thermal Shields. WeatherShields must be installed as 360° units to maintain their integrity and weather resistance.
Construction / Installation ProcedureThe bottom shield's weather barrier covers approximately 240° of the unit's circumference. The top weather barrier is providedas a separate piece from the top half of insulation. Once the top insulation piece is installed, this top weather barrier overlapsthe bottom weather barrier to act as a watershed, and is then attached with two strips of self-sealing tape, sealing it to the lower half of the unit. If a top metal shield is required, it can be slid into place completing the unit. Insulation and jacketing extend beyond the steel protection shield for a neat, weather-tight connection with the adjoining insulation.
Standard weather barrier layer is Ventureclad aluminum jacketing, either smooth or stucco embossed.
We can also provide :• PVC Jacketing - 0.020” or 0.030” thickness. Colors to match adjoining system requirements.• Aluminum Jacketing - 0.016” or 0.020” thickness. Smooth or stucco embossed.• Stainless Steel Jacketing - 0.010” or 0.015” thickness. Smooth or stucco embossed.
32
WEATHERSHIELD UPGRADEProtection System for Outdoor Applications
For models NS10, NS20, NS50, NS60, NG30, NG40, NG70, NG80 and NA40.
35
AGREEMENTS: All agreements are subject to strikes, accidents or other causes beyond our control. Prices anddesigns are subject to change without notice.
TAXES: The buyer is liable for any Federal or State taxes, imposed on the seller.
WARRANTY: We guarantee for one year from date of shipment our manufactured products to the extent that wewill replace those having manufacturing defects when used for the purpose which we recommended. If goodsare defective, the amount of damage is the price of the defective goods only and no allowance will be made forlabor or expense of repairing defective goods or damage resulting from the same. We warrant the products wesell of other manufacturers to the extent of the warranties of their respective maker.
RETURNS: Permission to return standard stocked merchandise must be obtained in writing. Credit will be issuedsubject to the following:
1. Return freight charges must be prepaid.
2. All material must be in first-class condition and in box quantities on arrival at our plant; if not, reconditioning costs will be deducted from the credit memo.
3. Credit will be allowed on the basis of the price charges less a minimum handling charge of 20% and less any out-bound freight allowed or paid by us.
4. All Special, non-stocked and redesigned merchandise is Non-Returnable.
TERMS AND DESIGN: Subject to change without notice, refer to current price list for terms of sale.
CLAIMS: No claims for shortages allowed unless made in writing within ten (10) days of receipt of goods. Allmaterial sent out will be carefully counted and packed. Claims for goods damaged or lost in transit should bemade to the carrier as our responsibility ceases on delivery to the carrier.
36
TERMS OF SALE
200 CAMPUS DRIVE, R.R. 30MOUNT HOLLY, NEW JERSEY 08060
(609) 261-5353
FAX: (609) 261-3249
8411 OLD MARLBORO PIKEUPPER MARLBORO, MARYLAND 20772