Project: New Residence Client: Harley Truong Drawn: Harley Truong Address: 10 Anderson St Chifley Canberra Block: 1 Scale @ A3 1:100 Drawing No C02.7 Sec: 3 Date: 2.11.13 Revision: 12 Slab plan - House 1A Revision Date Checked Approved 12 2.11.13 HT HT 11 18.10.13 HT HT 10 1.8.13 HT HT 0 5 north 100 450 24570 450 2400 7530 50mm SETDOWN 400 800 8790 7590 50 50 50 50 20 150 120 FOR CONSTRUCTION 9mm PLYWOOD CLADDING TO GARAGE 3740 450 450 450 450 5520 5600 450 5600 450 5600 8240 450 1 FOOTINGS Scale: 1 : 100 2 SLAB Scale: 1 : 100 A SECTION Scale: 1 : 20 MIN 450mm WIDE x 450mm DEEP 20MPa STRIP FOOTING WITH 4-11 T-M TOP AND BOTTOM AND 300mm HIGH STEEL CLIPS AT 900mm CTRS 1800 2395 6000 120 400 LAP 2 IN 1 TERMITE BARRIER, DAMP PROOF MEMBRANE TYP MIN 200um DAMP PROOF MEMBRANE MIN 200um POLYTHENE TYP 18210 7350 DAMP PROOF MEMBRANE MIN 200um POLYTHENE 120mm 32MPa CONCRETE DRIVEWAY SL82 TOP AND BOTTOM B DRIVEWAY Scale: 1 : 20 120mm WITH 150mm EDGE THICKENING 32MPa SLAB SL82 TOP AND BOTTOM ON MIN 200um POLYTHENE. STEEL TROWEL FINISH 120 120 6180 350 900 TYP REFER PLUMBING PLAN C2.29 FOR LOCATION OF SLAB PENETRATIONS 100mm 32MPa SLAB SL82 TOP ON MIN 200um DPM STEEL TROWEL FINISH UNDISTURBED SOIL 'OZONE' SIP PANELS 15mm UNTREATED OSB 90mm PIR FOAM 15mm UNTREATED OSB TO BE INSTALLED TO MANUFACTURER SPECS WITH 3mm x 55mm RING SHAFT NAILS AT 150mm CNTRS TO TOP AND BOTTOM PLATES AND STUDS FFL HOUSE 20mm CORK FLOORING 70 A 2500 100mm 32MPa SLAB SL82 TOP ON MIN 200um DPM STEEL TROWEL FINISH * H3 TREATED SOLE PLATE * H3 TREATED BOTTOM PLATE * COAT BOTTOM 150mm OF OSB WITH BRUSH ON CHEMICAL PRESERVATIVE WALL CLADDING 19mm SCYON BATTEN 8mm SCYON MATRIX XPS FOAM MIN 220kPa COMPRESSIVE STRENGTH @ 10% DEFLECTION 3 x 50mm LAYERS (CERTIFICATION ON FIT-FOR-PURPOSE TO BCA REQUIRED BY SUPPLIER) 50 MIN 80mm EXPOSED SLAB EDGE FOR TERMITE INSPECTION AS PER AS3660.1 100 COMPACTED FILL 50mm WET AREA SLAB SETDOWN M10 GALV THREADED ROD CAST INTO FOOTINGS AT 900mm CTRS, 200mm DEEP MIN WALLS INSTALLED FIRST AND THEN USED AS FORMWORK FOR HOUSE AND GARAGE SLABS 150 MIN MIN 150 N12 PERIMETER BAR TYP N12 PERIMETER BAR WITH MIN 600mm LAPS TYP 2000 TYP 2000 TYP FFL GARAGE B SL82 TOP ALCOR ALUMINIUM SLIP JOINT 300um TYP 2 IN 1 TERMITE BARRIER, DAMP PROOF MEMBRANE MIN 200um TYP DAMP PROOF MEMBRANE MIN 200um POLYTHENE TYP MIN 450mm DEEP x 450mm WIDE 20MPa STRIP FOOTING WITH 4-11 T-M TOP AND BOTTOM AND 300mm HIGH STEEL CLIPS AT 900mm CTRS ALCOR ALUMINIUM SLIP JOINT 300um TYP 100 TYP 1750 200 x 160 x 12mm GALV BASE PLATES CAST INTO FOOTINGS WITH 4 X M12 THREADED RODS VAPOUR PERMEABLE MEMBRANE M10 GALV THREADED ROD CAST INTO FOOTINGS AT 900mm CTRS, 200mm DEEP MIN, 100mm PROTUDING ABOVE FOOTING 60 TYP