Top Banner
Carotid Angiography: Information Quality and Safety Michael J. Cowley, M.D., FSCAI
35

Carotid Angiography: Information Quality and Safety Michael J. Cowley, M.D., FSCAI.

Dec 26, 2015

Download

Documents

Marvin Pope
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Carotid Angiography: Information Quality and Safety Michael J. Cowley, M.D., FSCAI.

Carotid Angiography: Information Quality and Safety

Michael J. Cowley, M.D., FSCAI

Page 2: Carotid Angiography: Information Quality and Safety Michael J. Cowley, M.D., FSCAI.

Carotid AngiographyCarotid Angiography

Indications and contraindications

Non-invasive methods of vascular evaluation and their utility/appropriateness

Potential complications & management

Ability to assess risk / benefit

Essential Cognitive KnowledgeEssential Cognitive Knowledge

Page 3: Carotid Angiography: Information Quality and Safety Michael J. Cowley, M.D., FSCAI.

Carotid Angiography Carotid Angiography

Cerebrovascular pathology:Cerebrovascular pathology:•Atherosclerosis

- Typical disease states and appearance

- Unusual forms of disease

•Aneurysms

•AVM’s

•Bleed

•Tumor

Essential Cognitive KnowledgeEssential Cognitive Knowledge

Page 4: Carotid Angiography: Information Quality and Safety Michael J. Cowley, M.D., FSCAI.

Carotid Angiography

• Vascular Access

• Arch Angiography

• Selective angiography:

• Extracranial vessels

• Intracranial vessels

Technique

Page 5: Carotid Angiography: Information Quality and Safety Michael J. Cowley, M.D., FSCAI.

Carotid Angiography

• Vascular Access

• Arch Angiography

• Selective angiography:

• Extracranial vessels

• Intracranial vessels

Technique

Page 6: Carotid Angiography: Information Quality and Safety Michael J. Cowley, M.D., FSCAI.

Catheter Access

• Femoral approach whenever possible

• Better angle of entry to arch vessels

• Allows forming of complex curve catheters

• Brachial access is possible but:

• requires more advanced skills

• higher complication rates

Page 7: Carotid Angiography: Information Quality and Safety Michael J. Cowley, M.D., FSCAI.

Carotid Angiography

• Access

• Arch Angiography

• Selective angiography:

• Extracranial vessels

• Intracranial vessels

Technique

Page 8: Carotid Angiography: Information Quality and Safety Michael J. Cowley, M.D., FSCAI.

Aortic Arch Angiography

• To evaluate access to great vessels • Identify Type of arch

• Identlfy ; anatomic variants (anomalies)

• 5 or 6F Pigtail catheter

• 30-40 degree LAO view

• Field of view: origin of great vessels extending to the carotid bifurcation

• Patient’s head should be straight with chin turned upward

• Hand or power injection

• 15-20 ml/sec for 2 seconds

Page 9: Carotid Angiography: Information Quality and Safety Michael J. Cowley, M.D., FSCAI.

Courtesy of Mark Burket, M.D.

Conventional Arch

Page 10: Carotid Angiography: Information Quality and Safety Michael J. Cowley, M.D., FSCAI.

65-70%: Usual pattern

20-25%: Bovine arch (Left CCA from brachiocephalic)

3%: Separate origin of left vertebral

5%: Various patterns, including right

subclavian from distal arch

Aortic Arch AngiographyAortic Arch Angiography

Anatomic Features

Page 11: Carotid Angiography: Information Quality and Safety Michael J. Cowley, M.D., FSCAI.

TortuousRightCommonCarotid

LEFT

It’s Not Just The Arch That Gets Longer!

Page 12: Carotid Angiography: Information Quality and Safety Michael J. Cowley, M.D., FSCAI.

Aortic Arch Types

Page 13: Carotid Angiography: Information Quality and Safety Michael J. Cowley, M.D., FSCAI.

Carotid Angiography

• Access

• Arch Angiography

• Selective angiography:

• Extracranial vessels

• Intracranial vessels

Technique

Page 14: Carotid Angiography: Information Quality and Safety Michael J. Cowley, M.D., FSCAI.

Carotid Angiography

• Ipsilateral oblique and lateral views (additional views may be necessary)

• Contralateral carotid (Circle of Willis, collaterals, etc)

• 5 or 6 F with appropriate curve

• Intracranial angiography also important

Page 15: Carotid Angiography: Information Quality and Safety Michael J. Cowley, M.D., FSCAI.

Carotid Angiography

• Site of stenosis

• Bifurcation involvement

• Landing zone for EPD

• Patency of ECA

• Presence of ICA tortuosity

• Presence of ulceration

• Severity of stenosis

• Lesion length

• Degree of calcification

• Presence of thrombus

Key Information for Carotid Stenting

Page 16: Carotid Angiography: Information Quality and Safety Michael J. Cowley, M.D., FSCAI.

Catheter Shapes

• Simple Curve Catheters• Have only a primary (distal) curve• Do not need to be formed• May not be adequate in tortuous anatomy

• Complex Curve Catheters• Have a primary and secondary curve• Must be formed• Often will not track over standard wires

Page 17: Carotid Angiography: Information Quality and Safety Michael J. Cowley, M.D., FSCAI.

Simple Curved Simple Curved Catheters Catheters

IMAModified AR1 JR 4

‘Coronary catheters’

Consider using Consider using dedicated catheters!!!dedicated catheters!!!

Page 18: Carotid Angiography: Information Quality and Safety Michael J. Cowley, M.D., FSCAI.

Primary Curve Catheters

• First choice for most selective angiography

• Wide variety of catheters available, chose one and perfect its use

• Glide catheters provide improved tracking over softer wires

• Chose a catheter that will be less traumatic and still allow selection of the arch vessels

Page 19: Carotid Angiography: Information Quality and Safety Michael J. Cowley, M.D., FSCAI.

H1 or Vertebral Artery Catheter

These catheters work well for flat aortic arches

Page 20: Carotid Angiography: Information Quality and Safety Michael J. Cowley, M.D., FSCAI.

Complex Curved CathetersComplex Curved Catheters

Simmons 1, 2, and 3 curves VTK

Page 21: Carotid Angiography: Information Quality and Safety Michael J. Cowley, M.D., FSCAI.

Simmons Catheter:A Closer Look

• Ideal for Type II-III arch

• Technique Tip: Re-shape in subclavian artery with an exchange wire to avoid arch manipulations

Page 22: Carotid Angiography: Information Quality and Safety Michael J. Cowley, M.D., FSCAI.

Vitek, Simmons 1,2,3 Catheters

Selective Catheter Choice

Page 23: Carotid Angiography: Information Quality and Safety Michael J. Cowley, M.D., FSCAI.

Complex Curve Catheters

• Allow for access proximally displaced vessels (Type 2 & 3 Arch or bovine arch

• Can be formed by placing the primary curve in the left subclavian artery and advancing the secondary curve toward the ascending aorta

• Avoid forming in the ascending aorta whenever possible

• Do not track well over most wires

• May require exchange length wires to change to a simple curve catheter after access is obtained

Page 24: Carotid Angiography: Information Quality and Safety Michael J. Cowley, M.D., FSCAI.

Engaging a Simmons II Engaging a Simmons II Catheter

Page 25: Carotid Angiography: Information Quality and Safety Michael J. Cowley, M.D., FSCAI.

Carotid Angiography

• Dx catheter engages innominate and road map of carotid bifurcation done

• Stiff angled 0.035’ guide wire advanced into distal CCA or ECA under roadmap guidance

• Catheter advanced over guidewire into CCA

• Guidewire removed

• Angio performed in ipsilateral oblique and lateral views (and other views if necessary)

Right Common Carotid Artery

Page 26: Carotid Angiography: Information Quality and Safety Michael J. Cowley, M.D., FSCAI.

Extracranial:- Ipsilateral oblique- Lateral- AP

Intracranial:- AP cranial (Townes view)- Lateral- Ipsilateral oblique, caudal

Carotid Angiography ViewsCarotid Angiography Views

Page 27: Carotid Angiography: Information Quality and Safety Michael J. Cowley, M.D., FSCAI.

Right Carotid Artery

• Pass angled guidewire into CCA using road map image

• Avoid advancing wire across diseased segment

• Fix wire and advance catheter over wire

• Position catheter tip in porox 1/3 of CCA

• Remove wire slowly from catheter

Page 28: Carotid Angiography: Information Quality and Safety Michael J. Cowley, M.D., FSCAI.

Carotid Angiography

• Using roadmap, retract catheter from Asc Aorta with clockwise rotation

• Position catheter close to origin of L CCA and turn counter- clockwise to engage CCA

• Pass angled guidewire into CCA using road map image; avoid advancing across diseased segment

• Fix wire and advance catheter over wire

• Position catheter tip in porox 1/3 of CCA

• Remove wire slowly from catheter

Left Carotid Artery

Page 29: Carotid Angiography: Information Quality and Safety Michael J. Cowley, M.D., FSCAI.

Carotid Angiography

• Dx catheter engages innominate and road map of carotid bifurcation done

• Stiff angled 0.035’ guide wire advanced into distal CCA or ECA under roadmap guidance

• Catheter advanced over guidewire into CCA

• Guidewire removed

Right Common Carotid Artery

Page 30: Carotid Angiography: Information Quality and Safety Michael J. Cowley, M.D., FSCAI.

Intracerebral Angiography

• Anterior cerebral circulation viewed by PA cranial (15-20 degrees) and lateral views

• Important to visualize both arterial and venous phases:

- Intracerebral disease

- Collateral circulation

- Presence of AVM, aneurysm, isolated hemisphere

- Missing arterial phase vessels

(allows identification of embolization post CAS)

Page 31: Carotid Angiography: Information Quality and Safety Michael J. Cowley, M.D., FSCAI.

Carotid Angiography

• Non-ionic contrast preferred

• Minimize contrast volume used

• Use lower risk catheter curves when possible

• Minimize catheter manipulations

Avoiding Complications

Page 32: Carotid Angiography: Information Quality and Safety Michael J. Cowley, M.D., FSCAI.

Avoid Excessive catheter manipulation

Page 33: Carotid Angiography: Information Quality and Safety Michael J. Cowley, M.D., FSCAI.

Severe Atheroma of the Aorta

Page 34: Carotid Angiography: Information Quality and Safety Michael J. Cowley, M.D., FSCAI.

Carotid Access IssuesCarotid Access Issues

• Clinical status: Symptomatic vs Asx

• Technical challenges:

- Duration of catheter dwell time

- Number of catheter exchanges - Contrast volume, fluoro time

• High risk anatomic features (not high risk clinical features)

Complication Risk determined primarily by case selection

Complications

Page 35: Carotid Angiography: Information Quality and Safety Michael J. Cowley, M.D., FSCAI.

Carotid Angiography

• High quality baseline angiography is essential for optimal carotid stenting

• Understanding necessary elements and anatomic variations assures quality imaging

• Intracranial and extracranial angiography is essential for pre and post intervention

• Proper catheter selection and careful technique insures safest possible angiography

Summary