Carl D. Mottram, BA RRT RPFT Carl D. Mottram, BA RRT RPFT FAARC FAARC Director - Pulmonary Function Labs and Director - Pulmonary Function Labs and Rehabilitation Rehabilitation Associate Professor of Medicine - Mayo Clinic Associate Professor of Medicine - Mayo Clinic College of Medicine College of Medicine Quality Control of Quality Control of Exercise and Gas Exercise and Gas Exchange Equipment Exchange Equipment
19
Embed
Carl D. Mottram, BA RRT RPFT FAARC Director - Pulmonary Function Labs and Rehabilitation Associate Professor of Medicine - Mayo Clinic College of Medicine.
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Carl D. Mottram, BA RRT RPFT FAARCCarl D. Mottram, BA RRT RPFT FAARCDirector - Pulmonary Function Labs and RehabilitationDirector - Pulmonary Function Labs and Rehabilitation
Associate Professor of Medicine - Mayo Clinic College of MedicineAssociate Professor of Medicine - Mayo Clinic College of Medicine
Carl D. Mottram, BA RRT RPFT FAARCCarl D. Mottram, BA RRT RPFT FAARCDirector - Pulmonary Function Labs and RehabilitationDirector - Pulmonary Function Labs and Rehabilitation
Associate Professor of Medicine - Mayo Clinic College of MedicineAssociate Professor of Medicine - Mayo Clinic College of Medicine
Quality Control of Exercise and Quality Control of Exercise and Gas Exchange EquipmentGas Exchange Equipment
Quality Control of Exercise and Quality Control of Exercise and Gas Exchange EquipmentGas Exchange Equipment
• Guidelines for Exercise Testing in the Guidelines for Exercise Testing in the Pediatric Age GroupPediatric Age Group - Council on - Council on Cardiovascular Disease in the Young, American Cardiovascular Disease in the Young, American Heart AssociationHeart Association
• Reginald Washington MD et al (Reginald Washington MD et al (Circulation 90:2166-2179, Circulation 90:2166-2179, 1994) 1994)
• Guidelines for Methacholine and Exercise Guidelines for Methacholine and Exercise Challenge Testing (Challenge Testing (Am J Respir Crit Care Med Vol 161. Am J Respir Crit Care Med Vol 161. pp 309-329, 2000)pp 309-329, 2000)
• ATS Pulmonary Function Laboratory ATS Pulmonary Function Laboratory Management and Procedure Manual Management and Procedure Manual (updated 2005) (updated 2005)
• www. thoracic.orgwww. thoracic.org
• Guidelines for Exercise Testing in the Guidelines for Exercise Testing in the Pediatric Age GroupPediatric Age Group - Council on - Council on Cardiovascular Disease in the Young, American Cardiovascular Disease in the Young, American Heart AssociationHeart Association
• Reginald Washington MD et al (Reginald Washington MD et al (Circulation 90:2166-2179, Circulation 90:2166-2179, 1994) 1994)
• Guidelines for Methacholine and Exercise Guidelines for Methacholine and Exercise Challenge Testing (Challenge Testing (Am J Respir Crit Care Med Vol 161. Am J Respir Crit Care Med Vol 161. pp 309-329, 2000)pp 309-329, 2000)
• ATS Pulmonary Function Laboratory ATS Pulmonary Function Laboratory Management and Procedure Manual Management and Procedure Manual (updated 2005) (updated 2005)
• Calibration every 3-6 monthsCalibration every 3-6 months
• Cycle ergometersCycle ergometers• static-bar and weightsstatic-bar and weights• dynamic-calibratorsdynamic-calibrators
• TreadmillTreadmill• Speed: beat length, stopwatch (subject on Speed: beat length, stopwatch (subject on
TM)TM)• % Grade % Grade = = Length of the treadmillLength of the treadmill
vertical height of elevation vertical height of elevation
Cardiopulmonary Exercise TestingCardiopulmonary Exercise TestingEquipment – Flowmeter and analyzersEquipment – Flowmeter and analyzers
• ATS/ERS standard for flow-volume ATS/ERS standard for flow-volume devicesdevices
• 3 liter syringe3 liter syringe• ± 3.5% or ± 50 ml ± 3.5% or ± 50 ml
• Gas analyzersGas analyzers• Paramagnetic, infrared, mass spectrometerParamagnetic, infrared, mass spectrometer• Linearity: 2-pt. calibration over range testingLinearity: 2-pt. calibration over range testing
• Laboratory personnelLaboratory personnel• 1-2 individuals: 100 watts cycle or 4.0 mph 1-2 individuals: 100 watts cycle or 4.0 mph
treadmill or below their anaerobic thresholdtreadmill or below their anaerobic threshold• Establish mean and confidence limits (95% Establish mean and confidence limits (95%
CI) for VOCI) for VO2, 2, VCOVCO2, 2, VVEE
• Perform at regular intervals depending on Perform at regular intervals depending on machine use or whenever data integrity are machine use or whenever data integrity are questionedquestioned
Cardiopulmonary Exercise Testing Cardiopulmonary Exercise Testing Path of Workflow - TestingPath of Workflow - Testing
Cardiopulmonary Exercise Testing Cardiopulmonary Exercise Testing Path of Workflow - TestingPath of Workflow - Testing
• ProtocolsProtocols• Cycle or treadmillCycle or treadmill• Steady state, incremental, rampSteady state, incremental, ramp• Defined (e.g. Bruce) or ad hocDefined (e.g. Bruce) or ad hoc
• ProtocolsProtocols• Cycle or treadmillCycle or treadmill• Steady state, incremental, rampSteady state, incremental, ramp• Defined (e.g. Bruce) or ad hocDefined (e.g. Bruce) or ad hoc
Cardiopulmonary Exercise Testing Cardiopulmonary Exercise Testing Path of WorkflowPath of Workflow
Cardiopulmonary Exercise Testing Cardiopulmonary Exercise Testing Path of WorkflowPath of Workflow
• Information managementInformation management•Timely posting of the data Timely posting of the data to the medical record or to the medical record or Information system Information system (HIS/LIS)(HIS/LIS)
•Average TRT: <1 day (15%), Average TRT: <1 day (15%), 1-2 d (30%), 3-4 d (27%), 5-6 d 1-2 d (30%), 3-4 d (27%), 5-6 d (15%), >7 d (3%)(15%), >7 d (3%)
• Information managementInformation management•Timely posting of the data Timely posting of the data to the medical record or to the medical record or Information system Information system (HIS/LIS)(HIS/LIS)
•Average TRT: <1 day (15%), Average TRT: <1 day (15%), 1-2 d (30%), 3-4 d (27%), 5-6 d 1-2 d (30%), 3-4 d (27%), 5-6 d (15%), >7 d (3%)(15%), >7 d (3%)