Top Banner
The Welch Allyn PC-Based Resting ECG Spend less time with paperwork and more time with your patients.
9

Cardioperfect_Spiroperfect

Apr 20, 2017

Download

Documents

Tubal Caín
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Cardioperfect_Spiroperfect

The Welch Allyn PC-Based Resting ECG

Spend less time with paperwork and more time with your patients.

Page 2: Cardioperfect_Spiroperfect

Convert to digital PC-based ECG technology and boost your efficiency with the Welch Allyn PC-Based Resting ECG

Tired of printing, scanning and shredding ECG records?

Improve Workflow and Efficiency> Preview a complete 12-lead report on large-screen prior to printing

and eliminate repeat ECGs

> ECG measurements speed physician review and interpretation

> Flexible reports that you can print on plain (standard) paper using an inkjet or laser printer. No need for expensive thermal paper. No more fading problems

Make Clinical Decisions with Confidence > Serial comparison of previous ECGs to highlight changes

> Easily monitor patients with intermittent arrhythmias

> Connect with your EHR and eliminate the need to sort through lengthy paper reports or interpret hard-to-read faxed copies of test results

Efficient Diagnosis Optional MEANS ECG interpretation software available for both adults and pediatric patients. Use on-screen report editor to change or add a diagnosis in seconds. Or select from preset menus customized to your needs, for simpli-fied review and editing of diagnostic tests.

Improved Condition Management Easily monitor trends and changes in patient history. Retrieve previous records with the touch of a key—no more digging through paper files looking for the right information.

Connect to your EHRNo printing or scanning, as data is already in the chart. Fax urgent referrals in no time directly from the system. And the database stores thousands of test records.

“The process of patient data gathering using the Welch Allyn product is excellent—now I don’t have to read 30 and 40 pages of ECGs. Now with the Welch Allyn devices, you hit one button

and everything is there for you. The process is so streamlined now, and that allows me to focus more on my patients.”

— Sasha Van Dyke, Exercise Physiologist, Cardiology of Tulsa

Bidirectional Connectivity Right at Your Fingertips While most devices only push information out to the EHR, our bidirectional connec-tivity when you use one of our 10 certified partners, enables immediate sharing of patient demographics and then critical test data between the EHR and the ECG so information is immediately available for review anytime, anywhere. The benefit? You eliminate transcription errors because you don’t have to continually re-enter data.

Maximize the power of your PC-Based ECG with the paperless efficiency and connectivity of the Welch Allyn CardioPerfect™ Workstation software.

Data Access Where and When You Need It

All the benefits of a full-featured, PC-based ECG in an affordable solution that speeds the turnaround of test results, makes patient diagnostic information more

readily available and enhances communication for you, your staff, and your patients.

Page 3: Cardioperfect_Spiroperfect

© 2009 Welch Allyn SM4006 Rev A

4341 State Street Road, PO Box 220, Skaneateles Falls, NY 13153-0220(p) 1.800.535.6663 (f) 1.315.685.2174 www.welchallyn.com

Technical Specifications Digital ECG module• Dimensions (L x W x D): 5.8" x 4.3" x 1.3" (147 mm x 108 mm x 32.5 mm)• Weight: 8.4 ounces (includes battery)• Integrated defibrillation protection• Computer interface: USB• 10-lead patient cable with banana electrode adapters• Frequency response: 0.05 – 150 Hz• Sampling rate: 600 sps

Filters• 25 to 35 Hz muscle tremor filter• Selectable 50/60 Hz

Software• Monitoring formats: 1 x 12, 4 x 3, 2x6• Print formats: 4 x 3, 2 x 6, average complexes, expanded

measurements matrix and rhythm strips• Print speeds: 5, 10, 12.5, 25, 50 and 100 mm/sec• Lead sensitivity: 5, 10 and 20 mm/mV software

• Selectable QTc formula: Bazett, Hodges or Fridericia

Minimum Computer Requirements (Recommended)•� Configuration: Tower or Desktop PC preferred; Laptop or Tablet.

Some tablet computers may not support data recording• CPU: Pentium 4 (or equivalent) or higher• Hard disk: 20 GB with 5 GB free space• RAM: 512 MB, 1 GB or higher recommended• Monitor Rresolution: 1024 x 768 True Color, 1280 x 1024 recommended,

15” or higher• Ports: 2 USB• Operating system: Windows 2000 SP4, XP SP2 (32 bit) or later,

Vista Business SP1 (32 bit) or later • Peripherals: Color printer recommended for spirometry. Compatible

with inkjet and laser printers

NOTES: Internet connection required for telemedicine option or to allow Welch Allyn to provide on-line technical support.PC running only CardioPerfect Worksation and EHR application during tests.

Ordering Information

CPR-UN-UB-D PC-Based Resting ECG, noninterpretive software—12-lead resting ECG system including: CardioPerfect™ Workstation software, digital ECG patient cable with USB connection, software for resting ECG—ECG measurements, rhythm/manual mode, average complexes, serial compari-sons of ECGs and measurements, 500 resting tab electrodes and electronic operator’s manual

CPR-UI-UB-D PC-Based Resting ECG, interpretive software—12-lead resting ECG system including: CardioPerfect™ Workstation software, digital ECG patient cable with USB connection, software for resting ECG—ECG measurements/interpretation, rhythm/manual mode, average complexes, serial comparisons of ECGs and measurements, 500 resting tab electrodes and electronic operator’s manual

101442 CPWS Resting ECG, interpretive software, and Spirometry Module Bundle— Includes all hardware components included in CPR-UI-UB-D and SPIRO-S

101444 CPWS Resting ECG, interpretive software, and ABPM-6100S Module Bundle— Includes all hardware components included in CPR-UI-UB-D and ABPM-6100S

101455 CPWS Resting ECG, interpretive software, and SpiroPerfect and ABPM-6100S Module Bundle—Includes all hardware components included in CPR-UI-UB-D, SPIRO-S and ABPM-6100S

CPT® Codes93000 Electrocardiogram, routine ECG with at least 12 leads; with interpretation and report

93005 Tracing only, without interpretation and report

93017 Interpretation and report only

93040 Rhythm ECG—1 to 3 leads, with interpretation and report

CPT is a registered trademark of the American Medical Association.

Welch Allyn PC-Based Resting ECG

Adult ECG 162.tif Enlarged complex.png

interp window copy.png

ECG comparison.png

ECG measurements window.png

Page 4: Cardioperfect_Spiroperfect

Precise information.Easier diagnoses. Better patient care.

The Welch Allyn SpiroPerfect™ PC-Based Spirometer

I N T R O D U C I N G

Page 5: Cardioperfect_Spiroperfect

Accurate, integrated patient information at your fingertips

• Fast, reliable pre- and post-bronchodilator FVC, SVC and MVV testing with automatic interpretation and reversibility analysis

> View real-time Flow/Volume Loop and Volume/Time graphs

> Instantly verify quality and variability of proper test performance

> Motivate children with incentive graphic—for pediatric patient coaching

> Reduce risk of cross contamination with single-usedisposable transducers

> Select single and multiple flow calibration protocols

• Easily monitor, review, store and print on your existing computer with the Welch Allyn CardioPerfect™ Workstation

> Choose from multiple predicted norms and report formats

> Compare previous tests with the Trending tool

> Make available to multiple staff via computer network

> Interface with Electronic Medical Records or patient management systems for onsite or offsite review of key data. Telemedicine option is available for e-mail transfer.

In seconds, you and your staff can see and compare accurate results from pulmonary function tests with the friendly, featherweight

Welch Allyn SpiroPerfect™ PC-Based Spirometer. You can clearly evaluate pulmonary obstruction or restriction, increase success

rates of patients who are undergoing smoking cessation, show progress, and help pediatric patients comply with test procedures.

Integrated. Customizable. Intuitive.

1

23

4

5 Display real time curves

Customizable parameters

Automatic interpretationIdentify type

and date

Patient records

Store, retrieve, print or edit patient records using the Welch Allyn CardioPerfect Workstation database.

Easily identify all diagnostic test types and dates each procedure was performed.

Automatic interpretation follows ATS InterpretativeStrategies and test reproducibility criteria.

See a quick snapshot of patient results. Select from 6 parameters to show real-time testing and summary.View measurement tables with 19 fully customizable parameters.

Display real time curves as Flow/Volume, Volume/Time, Flow/Time or Pre, Post. All efforts or best effort can bedisplayed on the same graph for easy comparison.

1

2

3

4

5

Page 6: Cardioperfect_Spiroperfect

Welch Allyn SpiroPerfect™

PC-Based SpirometerTransfers Test Data to Electronic MedicalRecords Systems

Enjoy the convenience of our accurate patentedDisposable Flow Transducers. Designed for use by an adult or child, these single-use disposablesminimize the risk of cross contamination. No sterilization, no cleanup—just safety and savings.

Get connected to your EMR through Welch Allyn’s CardioPerfect™ Workstation Software

The Welch Allyn SpiroPerfect™ PC-Based Spirometer downloads information to the Welch Allyn CardioPerfect™ Workstation

Software, which provides paperless efficiency as well as connectivity to many leading EMR systems. This software puts

patient records from a variety of Welch Allyn diagnostic instruments at your fingertips, giving you the ability to store, access,

review, compare and edit diagnostic test data from any computer on your network.

• Retrieve records with the touch of a key, and review and edit right on the screen

• Store thousands of records with ease

• Access information from your exam rooms, your office, or at home

• Fax or e-mail reports directly for consults

• Add additional cardiopulmonary diagnostic testing deviceslike ECG, ABPM, or Holter as your practice grows

• Copy and paste spirographs into Microsoft® Word

• Integrate with other patient information systems

• Uses passwords to assign/limit tasks so that data integrity is maintained

Coach, motivate and make testing more fun.Because children understand how to help the fireman put out the fire, the IncentiveScreen helps children understand your goals and comply with testing protocols.

Compare tests done on different days and clearly see progress. View three parameters at once as a percentage of predictive values or of absolute value.

Welch Allyn CardioPerfect™

Workstation Software

Page 7: Cardioperfect_Spiroperfect

Welch Allyn SpiroPerfect™ PC-Based Spirometer

To learn more about the Welch Allyn SpiroPerfect PC-Based Spirometer or to request a demonstration, contact your Welch Allyn representative.You’ll find a solution that not only improves patient care, but provides priceless peace of mind.

Technical SpecificationsSpiroPerfect Computer-based full diagnostic spirometerTests FVC, SVC, MVV, Pre- and Post-BDSensor Type PneumotachPower Equipment None, obtained from USB portAccuracy Meets or exceeds 1994 ATS standardReproducibility Meets or exceeds 1994 ATS standardVolume Range 0-14 LFlow Range ±14 L/secSoftware Microsoft® Windows® 2000 and XP compatiblePredictive Norms Berglund 1963, Crapo 1981, Composite,

Dockery 1983, ECCS/Quanjer 1993, Falaschetti 1995, Gulsvik 2001, Hedenström 1986, Hsu 1979, Knudson 1976, Koillinen 1998, Kory 1961, Morris 1971, NHANES III 1999 [Default], Polgar 1971, Schoenberg 1978, Solymar 1980, Viljanen 1981, Zapletal 1969Additional predictive norms can be added upon customer request

Interpretation 1991 ATS Interpretation Standards. Automatic can be disabled. Manual interpretation available.Lung age calculation

Reports Multiple report templates including FVC, SVC, MVV, measurement, and trend

Incentive Graphic FiremanParameters FVC, FIVC, FIV1, FIV1%, FEV0.5, FEV1, FEV2, FEV3,

FEV5, FEV6, FEV0.5%, FEV1%, FEV2%, FEV3%,FEV5%, FEV6%, PEF, FEF25 (MEF75), FEF50(MEF50), FEF75 (MEF25), FEF0.2-1.2, FEF25-75,FEF75-85, PIF, FIF50, FEF50/FIF50, FET SVC, ERV, IRV, VT, IC, BF, MV, Tin, Tex, Tin/Tex

Quality Checks Effort Acceptability and Test Reproducibility checksAudio and visual incentive for assistance in coaching patients

Connectivity Part of the CardioPerfect™ Diagnostic SuiteExport compatible with most electronic medical records programs Available in multiuser networkTelemedicine option for e-mail transfer

Minimum Computer Requirements (Recommended)Processor Intel® Pentium® III (Pentium IV or higher)Hard Drive 2 GB (4 GB or more)RAM 256 MB (512 MB or higher)Monitor Resolution (1024 x 768 true color)Operating Systems Microsoft® Windows® 2000 or XPCD-ROM Required for installationPrinters Color printer recommended. Compatible with

inkjet and laser printers. Laser printers require a minimum of 2 MB of memory

Performance StandardsSpiroPerfect meets or exceeds the following standards:ATS—American Thoracic Society, Standardization of Spirometry, 1994 UpdateERS—European Respiratory SocietyNIOSH—National Institute for Occupational Safety and HealthOSHA—Occupational Safety and Health AdministrationSSD—Social Security DisabilityECCS—European Community for Coal & Steel

Ordering InformationSPIRO-S SpiroPerfect™ PC-Based Spirometer Module: PC Spirometer Module with 3 L calibration syringe. Includes: sensor, pressure

tubing, 4 flow transducers, electronic operator’s manual, Welch Allyn CardioPerfect™ Workstation Software CD, 2 trainingposters, and quick reference card

SPIRO-NS SpiroPerfect™ PC-Based Spirometer Module: PC Spirometer Module without 3 L calibration syringe. Includes sensor, pressuretubing, 4 flow transducers, electronic operator’s manual, Welch Allyn CardioPerfect™ Workstation Software CD, 2 trainingposters, and quick reference card

703418 Disposable Spirometer Flow Transducer, 25 pk

703419 Disposable Spirometer Flow Transducer, 100 pk

703415 Pressure Tubing, 2 m

100680 Nose Clip (25 pk)

703480 Calibration Syringe (3 liters)

CPT Codes94010 Basic Spirometry—Spirometry including graphic record, total and timed vital capacity, expiratory flow rate measurement(s),

with or without maximal voluntary ventilation

94060 Pre- and Post-BD—Bronchospasm evaluation: spirometry as in 94010, before and after bronchodilator (aerosol or parental), or before and after exercise

© 2005 Welch Allyn SM2863 Rev. B

4341 State Street Road, PO Box 220, Skaneateles, NY 13153-0220(p) 1.800.535.6663 (f) 1.315.685.2174

www.welchallyn.com

Page 8: Cardioperfect_Spiroperfect

Advantage #1: Our innovative design prevents cross-contamination.The air inside the flow transducer's measurement pipe works as a buffer, preventing the expired air from entering the pressuretubing even during high flow rates (15 L/s) and repeated spirometry efforts.

The maximal differential pressure signal of the flow transducer is ±77 mm H2O, corresponding to a flow of ±15 L/s. Averageatmospheric pressure is 10 000 mm H2O. The air is therefore compressed in the pressure tubing up to

77 / 10 000 parts = 0.77 %

In 2-meter long pressure tubing, this amounts to

0.77 % x 2000 mm = 15.4 mm

Since the internal diameter of the pressure tubing is 1.5 mm, the cross-sectional area is 1.77 mm2. The amount of air enteringthe flow transducer's measurement pipe during the expiration amounts to

15.4 mm x 1.77 mm2 = 27.2 mm3

This is the maximal volume of expired air entering the measurement pipe of the flow transducer via the pressure-sampling holeat the top of the measurement pipe. In the measurement pipe, the "contaminated" air will start moving toward the pressure tubing adapter. The air entering the measurement pipe through the hole at the top of the measurement pipe will potentiallyreach the pressure tubing first.

Because the maximal volume of expired air entering the measurement pipe of the flow transducer is 27.2 mm3, and the air volume in the measurement pipe between the adapter and pressure-sampling hole is 136.3 mm3, the air buffer between thecontaminated air and the pressure tubing adapter is

136.3 mm3 - 27.2 mm3 = 109.1 mm3

This air buffer prevents the aerosols of the contaminated airfrom entering the pressure tubing even during repeated forcedexpiratory efforts. In slow efforts, the air entering the measure-ment pipe is even smaller.

Advantages of Disposable Flow Transducers

No Expired Air

Pressure Sampling Hole

Measurement Pipe

Page 9: Cardioperfect_Spiroperfect

Advantage #2: Bacteria filters are unnecessary. Because no contaminated air enters the pressure tubing, and because the flow transducers are discarded after each patientuse, no bacteria filters are needed. In fact, because Welch Allyn spirometers use a measuring principle based on pressure(pneumotachometer), filters would interfere with accuracy by adding resistance.

Advantage #3: Disposable flow transducers are more cost-effective, accurate, and convenient.

When procedural costs are taken into account, disposable flow transducers cost less than flow transducers that require disinfecting.

A disinfected flow transducer may retain solid particles on the screen or liquids in the duct, compromising accuracy.

Recalibration is required before reusing a disinfected flow transducer, whereas new flow transducers from the same manufacturing lot do not require a separate calibration.

Advantages of Disposable Flow Transducers

CUSTOMER SERVICEFor customer service, technical or clinical support, please contact Welch Allyn at (800) 535.6663.

4341 State Street Rd, PO Box 220, Skaneateles Falls, NY 13153(p) 1.800.535.6663 (f) 1.315.685.2174www.welchallyn.com

© 2005 Welch Allyn. SM2861 RevB