Page 1: Capnografía volumétrica G 5

1

1.70

6

.40

5

.70

0.

45

0

.30

5.

90

6

.40

11

.70

Capnografía Volumetrica por HAMILTON-G5

Page 2: Capnografía volumétrica G 5

1

1.70

6

.40

5

.70

0.

45

0

.30

5.

90

6

.40

11

.70

Capnography – A measure of venti lation

Metabolism

CO2

Transport

CO2

ETCO2

RR

Ventilation

CO2

Page 3: Capnografía volumétrica G 5

1

1.70

6

.40

5

.70

0.

45

0

.30

5.

90

6

.40

11

.70

CapnographyCapnography

Increase in ETCO2 Decrease in ETCO2

• Increased muscular activity (shivering)• Malignant hyperthermia

• Increased cardiac output (during resuscitation)

• Bicarbonate infusion• Tourniquet release

• Effective drug therapy for bronchospasm

• Decreased minute ventilation

• Decreased muscular activity (muscle relaxants)

• Hypothermia

• Decreased cardiac output (cardiac arrest)

• Pulmonary embolism

• Bronchospasm• Increased minute ventilation

Physiologic Factors Affecting ETCO2 Levels

Page 4: Capnografía volumétrica G 5

1

1.70

6

.40

5

.70

0.

45

0

.30

5.

90

6

.40

11

.70

CapnographyCapnography

• Infrared Absorption•CO2 molecules absorb infrared light energy at specific wavelengths•An infrared beam passes through a gas sample containing CO2

•A ratio of light absorbed to light transmitted to the light which reaches the photodetector is reported as ETCO2

Page 5: Capnografía volumétrica G 5

1

1.70

6

.40

5

.70

0.

45

0

.30

5.

90

6

.40

11

.70

Capnógrafia de Flujo CentralCapnógrafia de Flujo Central

� Mide, y muestra gráficas, de niveles de oxido de carbono en respiración exhalada en la vía aérea

� Capnografia provee advertencia temprana de problemas ventilatorios y aproxima presión arterial de CO2.

Page 6: Capnografía volumétrica G 5

1

1.70

6

.40

5

.70

0.

45

0

.30

5.

90

6

.40

11

.70

CapnographyCapnography

• Solid State vs. Chopper Wheel

Solid State CO2 Sensors No moving parts -

durability Use beam splitter to

measure IR light at two wavelengths

IR light source electronically pulsed

Chopper Wheel CO2 SensorsSpinning wheel - very fragileSpins to change parameter

measured by photodetector Gas sample to be measured

(data) Sample plus sealed gas

reference cell No light at all

Page 7: Capnografía volumétrica G 5

1

1.70

6

.40

5

.70

0.

45

0

.30

5.

90

6

.40

11

.70

Technology

MainstreamNondiverting

SidestreamDiverting

Page 8: Capnografía volumétrica G 5

1

1.70

6

.40

5

.70

0.

45

0

.30

5.

90

6

.40

11

.70

CapnographyCapnography

• Mainstream

vs.Sidestream

E T C O 2

R R

E T C O 2

R R

Page 9: Capnografía volumétrica G 5

1

1.70

6

.40

5

.70

0.

45

0

.30

5.

90

6

.40

11

.70

Capnography

• Mainstream Technology Sensor placed in

ventilator circuit

IR sensor can not be contaminated by patient secretions!

Measurement made at the patient’s airway

Fast response time

No water traps or tubing needed - hassle free

Sensor

E T C O 2

R R

Page 10: Capnografía volumétrica G 5

1

1.70

6

.40

5

.70

0.

45

0

.30

5.

90

6

.40

11

.70

Capnography

• Sidestream Technology

Sensor located away from the airway

Measurement made by pump inside the monitor

Slower response time

Water traps and tubing required making set-up difficult

Sensorinside monitor

E T C O 2

R R

Page 11: Capnografía volumétrica G 5

1

1.70

6

.40

5

.70

0.

45

0

.30

5.

90

6

.40

11

.70

Capnografía Convencional: CO2 Vs Tiempo

• End-tidal CO2 puede no reflejar el nivel de CO2 Alveolar

• No suminstra informacion del volumen de CO2

• No es posible las mediciones de espacio muerto

• El capnograma puede ser engañoso

• La Inhalacion y exhalation no refleja una ventilación efectiva

A-B: Inhalation

B-D: Exhalation

Page 12: Capnografía volumétrica G 5

1

1.70

6

.40

5

.70

0.

45

0

.30

5.

90

6

.40

11

.70

Capnograma con inhalació n profunda

CO2

tiempo

Page 13: Capnografía volumétrica G 5

1

1.70

6

.40

5

.70

0.

45

0

.30

5.

90

6

.40

11

.70

Capnograma con inhalació n superficial

CO2

tiempo

CO2

tiempo

inhalación profunda

Inhalación superficial

Page 14: Capnografía volumétrica G 5

1

1.70

6

.40

5

.70

0.

45

0

.30

5.

90

6

.40

11

.70

Plotting CO2 vs time: is this end-tidal CO2?

• End-tidal CO2 may not reflect alveolar CO2 level

• No information on volume of CO2

• Dead space measurements are not possible

• Shape of capnogram may be misleading: a flat alveolar plateau may not be flat; inhalation and exhalation may not reflect effective ventilation

A-B: Inhalation

B-D: Exhalation

Page 15: Capnografía volumétrica G 5

1

1.70

6

.40

5

.70

0.

45

0

.30

5.

90

6

.40

11

.70

Que es la Capnografía Volumetrica ?

Page 16: Capnografía volumétrica G 5

1

1.70

6

.40

5

.70

0.

45

0

.30

5.

90

6

.40

11

.70

Integració n de Flujo y CO 2Integració n de Flujo y CO 2

CO2 Volumétrico

Page 17: Capnografía volumétrica G 5

1

1.70

6

.40

5

.70

0.

45

0

.30

5.

90

6

.40

11

.70

CO2 Volumétrico

Integration of Flow & CO 2

Page 18: Capnografía volumétrica G 5

1

1.70

6

.40

5

.70

0.

45

0

.30

5.

90

6

.40

11

.70

Capnograma Volumetrico con inhalació n profunda

CO2

volumen

Page 19: Capnografía volumétrica G 5

1

1.70

6

.40

5

.70

0.

45

0

.30

5.

90

6

.40

11

.70

Capnograma Vol. Inhalació n profunda Vs Superficial

CO2

volumen

Inhalacion superficial

CO2

volumen

Inhalación profunda

Page 20: Capnografía volumétrica G 5

1

1.70

6

.40

5

.70

0.

45

0

.30

5.

90

6

.40

11

.70

Phase I - Airway Gas

Page 21: Capnografía volumétrica G 5

1

1.70

6

.40

5

.70

0.

45

0

.30

5.

90

6

.40

11

.70

Fase II - Gas Transicional ` Fase II - Gas Transicional `

Page 22: Capnografía volumétrica G 5

1

1.70

6

.40

5

.70

0.

45

0

.30

5.

90

6

.40

11

.70

Fase III - Gas AlveolarFase III - Gas Alveolar

Page 23: Capnografía volumétrica G 5

1

1.70

6

.40

5

.70

0.

45

0

.30

5.

90

6

.40

11

.70

Curva de Capnografía Volumetrica Curva de Capnografía Volumetrica

ExhaledVolume

% CO2

Volume CO2

Page 24: Capnografía volumétrica G 5

1

1.70

6

.40

5

.70

0.

45

0

.30

5.

90

6

.40

11

.70

Waveform Phases

% CO2

ExhaledVolume

Page 25: Capnografía volumétrica G 5

1

1.70

6

.40

5

.70

0.

45

0

.30

5.

90

6

.40

11

.70

Volumetric CO 2 – Leap Frog Technology

Page 26: Capnografía volumétrica G 5

1

1.70

6

.40

5

.70

0.

45

0

.30

5.

90

6

.40

11

.70

Capnografía Volumetrica (SBCO 2)

Page 27: Capnografía volumétrica G 5

1

1.70

6

.40

5

.70

0.

45

0

.30

5.

90

6

.40

11

.70

Fases de la Capnografía Volumetrica (SBCO2 )

Fase 3: • Area del gas alveolar de intercambio. Es representativa de la distribución del gas a nivel alveolar.Indicador sensible de la función pulmonar.

• ↑ de la pendiente muestra una mala distribución del gas (EPOC)

Fase 1: • Representa el gas exhalado desde las vías áereas superiores las cuales generalmente no tienen CO2. • ↑ describe un ↑ en el espacio muerto de vías aereas.

Fase 2: • Fase de trasnsición desde las vias aereas superiores a las inferiores Muestra los cambios en perfusión • ↓ de la pendiente muestra reducción en la perfusión.

Page 28: Capnografía volumétrica G 5

1

1.70

6

.40

5

.70

0.

45

0

.30

5.

90

6

.40

11

.70

Volumetric CO 2 – Leap Frog Technology

• EtCO2

• Capnogram

• Respiratory Rate

Capnography Volumetric CO2

• CO2 Elimination

• Deadspace

• Alveolar Ventilation

• Physiologic Vd/Vt

Page 29: Capnografía volumétrica G 5

1

1.70

6

.40

5

.70

0.

45

0

.30

5.

90

6

.40

11

.70

“Normal” values

Page 30: Capnografía volumétrica G 5

1

1.70

6

.40

5

.70

0.

45

0

.30

5.

90

6

.40

11

.70

Lo grandioso de combinar el flujo y la medida de CO2

… Para mejorar la seguridad de los pacientes

• Mostrar y evitar la ventilación ineficiente

• Cuantificar el espacio muerto

• Identificar intubación gastrica, embolismo pulmonar

• Monitor de evolución de la sepsis

• Lo acerca al conocimiento del consumo metabolico

• Mostrar COPD, asma

• Use la capnografía volumetrica como un predictor temprano de riesgo en los pacientes

• Indicador muy sensible del estatus cardio-Respiratorio del paciente

Page 31: Capnografía volumétrica G 5

1

1.70

6

.40

5

.70

0.

45

0

.30

5.

90

6

.40

11

.70

Capnografía Volumetrica en HAMILTON-G5

Page 32: Capnografía volumétrica G 5

1

1.70

6

.40

5

.70

0.

45

0

.30

5.

90

6

.40

11

.70

HAMILTON-G5 CO2 measurement

• Technical aspects:

• Optional CO2 preparation kit (without sensor)

• Mainstream OEM CAPNOSTAT 5 sensor– Only HAMILTON MEDICAL’s CAPNOSTAT 5 sensor can be used!

Page 33: Capnografía volumétrica G 5

1

1.70

6

.40

5

.70

0.

45

0

.30

5.

90

6

.40

11

.70

HAMILTON-G5: Workshop options HW options

•Hardware options

• 159136 CO2 preparation kit

Page 34: Capnografía volumétrica G 5

1

1.70

6

.40

5

.70

0.

45

0

.30

5.

90

6

.40

11

.70

Modulo de CO2

Page 35: Capnografía volumétrica G 5

1

1.70

6

.40

5

.70

0.

45

0

.30

5.

90

6

.40

11

.70

HAMILTON-G5: Workshop options

•Hardware options

• 159136 CO2 preparation kit

• 281718 HAMILTON CAPNOSTAT-5 CO2 sensor

Page 36: Capnografía volumétrica G 5

1

1.70

6

.40

5

.70

0.

45

0

.30

5.

90

6

.40

11

.70

Sensor de CO2

Page 37: Capnografía volumétrica G 5

11.70

6.40

5.70

0.45

0.30

5.90

6.40

11.70

Tecnología Mainstream

Page 38: Capnografía volumétrica G 5

11.70

6.40

5.70

0.45

0.30

5.90

6.40

11.70

Capnogramas en HAMILTON-G5

convencional

volumetrica

Page 39: Capnografía volumétrica G 5

11.70

6.40

5.70

0.45

0.30

5.90

6.40

11.70

Conclusions

Page 40: Capnografía volumétrica G 5

11.70

6.40

5.70

0.45

0.30

5.90

6.40

11.70

Volumetric capnography improves effectivenessPetCO2: Assess

adequacy of ventilation

V’CO2: Get a grip on metabolic rate

Combine with PaCO2 (VD/VT): Use as an early risk predictor, early warning for pulmonary embolism

Page 41: Capnografía volumétrica G 5

11.70

6.40

5.70

0.45

0.30

5.90

6.40

11.70

Volumetric capnography improves safety

V’alv, VDaw: Improve patient safety, quantify dead space and avoid inefficient ventilation

PetCO2: Identify gastric intubation

Unique feature of HAMILTON-G5

slopeCO2: Reveal COPD, asthma

V’CO2: Monitor the course of sepsis

Page 42: Capnografía volumétrica G 5

11.70

6.40

5.70

0.45

0.30

5.90

6.40

11.70

Lecturas Recomnedadas

Page 43: Capnografía volumétrica G 5

11.70

6.40

5.70

0.45

0.30

5.90

6.40

11.70

Lecturas Recomnedadas

Page 44: Capnografía volumétrica G 5

11.70

6.40

5.70

0.45

0.30

5.90

6.40

11.70

Lecturas Recomnedadas

Page 45: Capnografía volumétrica G 5

11.70

6.40

5.70

0.45

0.30

5.90

6.40

11.70

Lecturas Recomnedadas

Page 46: Capnografía volumétrica G 5

11.70

6.40

5.70

0.45

0.30

5.90

6.40

11.70