ACP CONCRETE LTD We are Part of the Thomas Armstrong Group www.thomasarmstrongacpconcrete.co.uk APPLICATIONS ACP prestressed, precast concrete walls panels are designed to provide structural walls across various applications. • AD Silage Clamps • Tanks (above & below ground) – Open and Closed Concrete Structure • Recycling Bunker Walls – recycling and composting waste products • Waste Transfer Walls • Bunker Walls • Security Walls/Compartments • Grain Storage • Push Walls • Retaining Walls • Division Walls A MODERN ALTERNATIVE to traditional ‘L-Shapes’, this wall system is designed to provide a complete retaining wall solution, making it ideal for both above and below ground applications. Cantilever Prestresssed Precast Retaining Wall are suitable for a diverse range of application including bulk commodity stores, waste stores, above and below ground tanks, biomass stores & silage clamps and earth retaining structures for car parks, goods yards and landscaping projects. This cost-effective walling solution offers fast installation whilst still providing a high quality, durable and robust prestressed wall. Manufactured offsite in controlled factory environment conditions from high grade 60 N/mm²engineering grade concrete to recognised industry standards i.e Eurocode 2, BS8110, BS5502 Part 22. STANDARD WALL PANELS SIZES CANTILEVER - VERTICAL PRESTRESSED PRECAST CONCRETE RETAINING WALL Length Depth / Thickness Width
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
ACP CONCRETE LTD We are Part of the Thomas Armstrong Group
www.thomasarmstrongacpconcrete.co.uk
APPLICATIONSACP prestressed, precast concrete walls panels are designed to provide structural walls across various applications.
• AD Silage Clamps
• Tanks (above & below ground) – Open and Closed ConcreteStructure
• Recycling Bunker Walls – recycling and composting wasteproducts
• Waste Transfer Walls
• Bunker Walls
• Security Walls/Compartments
• Grain Storage
• Push Walls
• Retaining Walls
• Division Walls
A MODERN ALTERNATIVE to traditional ‘L-Shapes’, this wall system is designed to provide a complete retaining wall solution, making it ideal for both above and below ground applications.
Cantilever Prestresssed Precast Retaining Wall are suitable for a diverse range of application including bulk commodity stores, waste stores, above and below ground tanks, biomass stores & silage clamps and earth retaining structures for car parks, goods yards and landscaping projects. This cost-e�ective walling solution o�ers fast installation whilst still providing a high quality, durable and robust prestressed wall.
Manufactured o�site in controlled factory environment conditions from high grade 60 N/mm²engineering grade concrete to recognised industry standards i.e Eurocode 2, BS8110, BS5502 Part 22.
MaterialsAll materials are sourced in accordance with the appropriate British Standard and in accordance with the ACP performance speci�cations.
• Concrete typical 28 days strengths are 60 N/mm²
• Concrete strength at transfer 30 N/mm²
• Water cement ratio 0.45 Maximum
• Reinforcement typically 9.3mm dia prestressingstrand
DesignAll units are CE Marked and designed in accordance with Euro Code 2, and BS8110.
Unit design is typically to Class 2 or Class 3 in non-aggressive environments with a limiting crack width of 0.1mm unless otherwise stated.
It is the client’s responsibility to provide the anticipated loading data including bulk material density, angle of internal shear resistance and load condition including any surcharge or impact loadings so that the correct panel type can be advised.
ManufactureACP wall panels are manufactured in the long line prestressed method. Units are wet cast into steel moulds with under plate heating to assist in accelerated curing.
TolerancesCross-sectional tolerances are within limits set out in clause 6.2.8.3 of BS8110:1997. ACP acceptable tolerances for standard prestressed units are as follows below:
Special cast units will be to tolerances laid down in BS8110 where casting techniques permit.
DISCLAIMER: Please note that any information provided is to be used as a guide only. Any lifting/handling operations should be carried out by trained and competent personnel only. ACP (Concrete) Limited will not be held responsible for any damage or injuries in connection with handling or installation not carried out by ACP (Concrete) Limited.