Top Banner
Cambium PTP 810 Series User Guide System Release 810-01-00
601
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Cambium network ptp 810 series 01 00 user guide

Cambium PTP 810 Series User Guide System Release 810-01-00

Page 2: Cambium network ptp 810 series 01 00 user guide

phn-2779_001v000 (Jul 2012)

Accuracy

While reasonable efforts have been made to assure the accuracy of this document, Cambium Networks assumes no liability resulting from any inaccuracies or omissions in this document, or from use of the information obtained herein. Cambium reserves the right to make changes to any products described herein to improve reliability, function, or design, and reserves the right to revise this document and to make changes from time to time in content hereof with no obligation to notify any person of revisions or changes. Cambium does not assume any liability arising out of the application or use of any product, software, or circuit described herein; neither does it convey license under its patent rights or the rights of others. It is possible that this publication may contain references to, or information about Cambium products (machines and programs), programming, or services that are not announced in your country. Such references or information must not be construed to mean that Cambium intends to announce such Cambium products, programming, or services in your country.

Copyrights

This document, Cambium products, and 3rd Party software products described in this document may include or describe copyrighted Cambium and other 3rd Party supplied computer programs stored in semiconductor memories or other media. Laws in the United States and other countries preserve for Cambium, its licensors, and other 3rd Party supplied software certain exclusive rights for copyrighted material, including the exclusive right to copy, reproduce in any form, distribute and make derivative works of the copyrighted material. Accordingly, any copyrighted material of Cambium, its licensors, or the 3rd Party software supplied material contained in the Cambium products described in this document may not be copied, reproduced, reverse engineered, distributed, merged or modified in any manner without the express written permission of Cambium. Furthermore, the purchase of Cambium products shall not be deemed to grant either directly or by implication, estoppel, or otherwise, any license under the copyrights, patents or patent applications of Cambium or other 3rd Party supplied software, except for the normal non-exclusive, royalty free license to use that arises by operation of law in the sale of a product.

Restrictions

Software and documentation are copyrighted materials. Making unauthorized copies is prohibited by law. No part of the software or documentation may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means, without prior written permission of Cambium.

License Agreements

The software described in this document is the property of Cambium and its licensors. It is furnished by express license agreement only and may be used only in accordance with the terms of such an agreement.

High Risk Materials

Components, units, or 3rd Party products used in the product described herein are NOT fault-tolerant and are NOT designed, manufactured, or intended for use as on-line control equipment in the following hazardous environments requiring fail-safe controls: the operation of Nuclear Facilities, Aircraft Navigation or Aircraft Communication Systems, Air Traffic Control, Life Support, or Weapons Systems (High Risk Activities). Cambium and its supplier(s) specifically disclaim any expressed or implied warranty of fitness for such High Risk Activities.

© 2012 Cambium Networks Limited. All Rights Reserved.

Page 3: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide

phn-2779_001v000 (Jul 2012) I

Important safety information

This section describes important safety guidelines that must be observed by personnel installing or operating PTP 810 equipment.

To prevent loss of life or physical injury, observe the safety guidelines in this section.

Power lines

Exercise extreme care when working near power lines.

Working at heights

Exercise extreme care when working at heights.

Grounding and protective earth

The outdoor unit (ODU) and modular modem unit (MMU) for the PTP 810 must be properly grounded. It is the user’s responsibility to install the equipment in accordance with national regulations. In the USA, follow Section 810 of the National Electric Code, ANSI/NFPA No.70-1984 (USA). In Canada, follow Section 54 of the Canadian Electrical Code. These codes describe correct installation procedures for grounding the ODU, MMU, mast, lead-in wire and discharge unit, size of grounding conductors and connection requirements for grounding electrodes. Other regulations may apply in different countries and therefore it is recommended that installation of the outdoor unit be contracted to a professional installer.

The ODU and MMU must be grounded to a protective earth in accordance with the Local Electrical Regulations.

Page 4: Cambium network ptp 810 series 01 00 user guide

Important safety information

II phn-2779_001v000 (Jul 2012)

Electrical safety

The power cable connections must meet International Electrotechnical Commission (IEC) safety standards.

Always power down and unplug the equipment before servicing.

When using alternative DC supplies, such as battery-backed DC power source, the supply must be SELV rated.

Primary disconnect device

The power supply must include a primary disconnect device with appropriate fusing.

External cables

Safety may be compromised if outdoor rated cables are not used for connections that will be exposed to the weather.

RF exposure near the antenna

Strong radio frequency (RF) fields will be present close to the antenna when the transmitter is on. Always mute the transmitter before undertaking maintenance activities in front of the antenna.

Ensure that people cannot stand or walk in front of the antenna within ± 10 degrees of the antenna axis and within the minimum distances listed in Table 220 (ETSI) or Table 221 (FCC). The minimum distances in these tables have been calculated using worst-case assumptions. Reduced separation distances may be appropriate under some circumstances. Further details are provided in Radiation hazard assessment on page 4-83.

Page 5: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide

phn-2779_001v000 (Jul 2012) i

Contents

Important safety information ........................................................................................... I

About This User Guide ..................................................................................................... 1

General information ..................................................................................................................... 2

Version information ................................................................................................................ 2

Contacting Cambium Networks ............................................................................................. 2

Problems and warranty ................................................................................................................ 4

Security advice ............................................................................................................................. 6

Warnings, cautions, and notes ..................................................................................................... 7

Caring for the environment .......................................................................................................... 8

Licensing requirements ............................................................................................................... 9

Operating license ................................................................................................................... 9

Cambium license agreement .................................................................................................. 9

Chapter 1: Product description .................................................................................. 1-1

Overview ................................................................................................................................... 1-2

Key features ........................................................................................................................ 1-2

Supported bands and frequencies ...................................................................................... 1-3

Typical users and applications ............................................................................................ 1-4

System components ............................................................................................................ 1-4

Link types ............................................................................................................................ 1-5

Dual 1+0 links ..................................................................................................................... 1-6

Wireless link aggregation ................................................................................................... 1-7

Modular modem unit (MMU) .................................................................................................... 1-8

MMU description ................................................................................................................ 1-8

Required modules ............................................................................................................... 1-8

Power Supply Module ......................................................................................................... 1-8

Control Module ................................................................................................................. 1-10

Modem Module ................................................................................................................. 1-11

Standard Master I/O module ............................................................................................. 1-12

GigE Master I/O module .................................................................................................... 1-13

Additional modules ............................................................................................................ 1-14

Additional Power Supply Module ...................................................................................... 1-15

Page 6: Cambium network ptp 810 series 01 00 user guide

Contents

ii phn-2779_001v000 (Jul 2012)

Additional Modem Module ................................................................................................ 1-15

Expansion I/O: 16 × E1/T1 ................................................................................................ 1-16

Further reading on the MMU ........................................................................................... 1-17

Outdoor unit (ODU) ................................................................................................................. 1-18

ODU description ................................................................................................................ 1-18

ODU interfaces .................................................................................................................. 1-19

Further reading on the ODU ............................................................................................. 1-23

Antennas and couplers ............................................................................................................ 1-24

Antennas ........................................................................................................................... 1-24

Remote mounting kits (RMKs) .......................................................................................... 1-26

Coupler mounting kits....................................................................................................... 1-27

Direct mount dual-polar antennas .................................................................................... 1-29

Further reading on antennas and couplers ....................................................................... 1-30

Cabling and lightning protection ............................................................................................ 1-31

Lightning protection ......................................................................................................... 1-31

ODU to MMU connections ................................................................................................ 1-31

MMU to network connections ........................................................................................... 1-31

Cable grounding ................................................................................................................ 1-31

Further reading on cabling and lightning protection ....................................................... 1-33

Wireless operation .................................................................................................................. 1-34

Channel separation ........................................................................................................... 1-34

Channel bandwidth ........................................................................................................... 1-34

Modulation modes ............................................................................................................. 1-35

Adaptive power control ..................................................................................................... 1-35

Maximum receive power ................................................................................................... 1-36

Maximum transmit power ................................................................................................. 1-36

XPIC .................................................................................................................................. 1-36

Further reading on wireless operation ............................................................................. 1-37

Ethernet bridging in the customer network ........................................................................... 1-38

Transparent Ethernet service ........................................................................................... 1-38

Internal Ethernet switch ................................................................................................... 1-39

Spanning tree operation ................................................................................................... 1-40

Pause frame operation ...................................................................................................... 1-41

Ethernet link aggregation ................................................................................................. 1-41

Transparent wireless link aggregation (GigE Master I/O module) ................................... 1-42

VLAN bridging of Ethernet Traffic .................................................................................... 1-42

Quality of service for bridged Ethernet traffic ................................................................. 1-45

Page 7: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide

phn-2779_001v000 (Jul 2012) iii

Wireless link down alert .................................................................................................... 1-45

Further reading on Ethernet bridging .............................................................................. 1-46

Ethernet bridging in the management network ...................................................................... 1-47

Embedded management agent.......................................................................................... 1-47

Serial interface .................................................................................................................. 1-47

Ethernet interface ............................................................................................................. 1-47

Network management ....................................................................................................... 1-48

Spanning tree operation ................................................................................................... 1-49

Network management quality of service .......................................................................... 1-49

System management ............................................................................................................... 1-50

Protocol interfaces ............................................................................................................ 1-50

Web server ........................................................................................................................ 1-50

Command line interface .................................................................................................... 1-50

Identity-based user accounts ............................................................................................ 1-51

Link configuration wizard ................................................................................................. 1-52

Alarms ............................................................................................................................... 1-52

SNMP ................................................................................................................................ 1-53

Simple Network Time Protocol (SNTP) ............................................................................. 1-54

System logging (syslog) .................................................................................................... 1-54

Flexible capacity upgrades ............................................................................................... 1-54

Application software storage and upgrade ....................................................................... 1-55

Restore system defaults .................................................................................................... 1-56

Further reading on system management .......................................................................... 1-56

TDM bridging .......................................................................................................................... 1-57

E1/T1 capacity ................................................................................................................... 1-57

E1/T1 clocking ................................................................................................................... 1-58

Identification and mapping of E1/T1 circuits and ports ................................................... 1-59

E1/T1 switching in 1+0 and 1+1 link types ...................................................................... 1-59

Dual 1+0 links ................................................................................................................... 1-60

E1/T1 switching in 2+0 co-polar, 2+0 cross-polar and 2+0 XPIC link types ................... 1-61

Loopback ........................................................................................................................... 1-62

Further reading on TDM bridging .................................................................................... 1-62

Chapter 2: Planning considerations ........................................................................... 2-1

Link planning ............................................................................................................................ 2-2

Process ................................................................................................................................ 2-2

Site selection ....................................................................................................................... 2-3

Wind loading ....................................................................................................................... 2-3

Page 8: Cambium network ptp 810 series 01 00 user guide

Contents

iv phn-2779_001v000 (Jul 2012)

Maximum IF cable length ................................................................................................... 2-3

PTP LINKPlanner ................................................................................................................ 2-4

Grounding and lightning protection ......................................................................................... 2-7

The need for power surge protection ................................................................................. 2-7

Standards ............................................................................................................................ 2-7

Lightning Protection Zones ................................................................................................. 2-8

General protection requirements ........................................................................................ 2-9

Protection requirements for a mast or tower installation................................................. 2-10

Protection requirements for the ODU on a high rise building .......................................... 2-12

Data network planning ............................................................................................................ 2-16

IP interface ........................................................................................................................ 2-16

Quality of service for bridged Ethernet traffic ................................................................. 2-16

Fast Ethernet port shutdown ............................................................................................ 2-18

TDM network planning ........................................................................................................... 2-19

E1/T1 termination points and pass-through ..................................................................... 2-19

Protection requirements ................................................................................................... 2-19

2+0 link failover preference ............................................................................................. 2-20

TDM and Ethernet traffic capacity tradeoffs .................................................................... 2-20

Planning 1+0 links .................................................................................................................. 2-22

Concept of a 1+0 link........................................................................................................ 2-22

Antenna, ODU and MMU configurations for 1+0 ............................................................. 2-22

Planning 1+1 links .................................................................................................................. 2-25

Concept of a 1+1 Hot Standby link .................................................................................. 2-25

Concept of a 1+1 Hot Standby Spatial Diversity link ....................................................... 2-25

Antenna, ODU and MMU configurations for 1+1 links .................................................... 2-26

Designating primary and secondary units ........................................................................ 2-30

Link planning for 1+1 Hot Standby links ......................................................................... 2-30

Link planning for Spatial Diversity ................................................................................... 2-30

Planning 2+0 links .................................................................................................................. 2-31

Concept of a 2+0 link........................................................................................................ 2-31

Antenna, ODU and MMU configurations for 2+0 ............................................................. 2-31

Frequency spacing ............................................................................................................ 2-36

Planning Dual 1+0 links.......................................................................................................... 2-37

BOM for ring and ribbon topologies ................................................................................. 2-37

1+0 Ribbon topology ......................................................................................................... 2-37

1+0 Ring topology ............................................................................................................ 2-38

Ordering components ............................................................................................................. 2-39

Page 9: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide

phn-2779_001v000 (Jul 2012) v

Ordering MMUs ................................................................................................................ 2-39

Ordering capacity upgrades and XPIC capability ............................................................. 2-40

Ordering antennas ............................................................................................................ 2-44

Ordering ODUs ................................................................................................................. 2-54

Ordering IF cable, grounding and LPUs ........................................................................... 2-65

Ordering RMKs and waveguides ....................................................................................... 2-70

Ordering coupler mounting kits ........................................................................................ 2-73

Ordering OMKs ................................................................................................................. 2-75

Ordering network connection components ....................................................................... 2-75

Chapter 3: Legal information ..................................................................................... 3-1

Cambium Networks end user license agreement ..................................................................... 3-2

Acceptance of this agreement ............................................................................................. 3-2

Definitions ........................................................................................................................... 3-2

Grant of license ................................................................................................................... 3-2

Conditions of use ................................................................................................................. 3-3

Title and restrictions ........................................................................................................... 3-4

Confidentiality ..................................................................................................................... 3-4

Right to use Cambium’s name ............................................................................................ 3-5

Transfer ............................................................................................................................... 3-5

Updates ............................................................................................................................... 3-5

Maintenance ........................................................................................................................ 3-5

Disclaimer ........................................................................................................................... 3-6

Limitation of liability ........................................................................................................... 3-6

U.S. government ................................................................................................................. 3-7

Term of license .................................................................................................................... 3-7

Governing law ..................................................................................................................... 3-7

Assignment .......................................................................................................................... 3-8

Survival of provisions .......................................................................................................... 3-8

Entire agreement ................................................................................................................ 3-8

Third party software ........................................................................................................... 3-8

Limit of liability ......................................................................................................................... 3-9

Chapter 4: Reference information .............................................................................. 4-1

Equipment specifications .......................................................................................................... 4-2

MMU specifications ............................................................................................................ 4-2

ODU specifications .............................................................................................................. 4-5

Flexible waveguide specifications ....................................................................................... 4-9

Coupler mounting kit specifications ................................................................................. 4-14

Page 10: Cambium network ptp 810 series 01 00 user guide

Contents

vi phn-2779_001v000 (Jul 2012)

MMU front panel connectors ............................................................................................ 4-16

Wireless specifications ............................................................................................................ 4-23

General wireless specifications ......................................................................................... 4-23

Frequency bands and channel separation ........................................................................ 4-24

Capacity license keys and frequency bands ...................................................................... 4-25

Maximum E1/T1 circuit capacity ...................................................................................... 4-27

Capacity, transmit power and sensitivity .......................................................................... 4-29

Data network specifications .................................................................................................... 4-73

Fast Ethernet specifications ............................................................................................. 4-73

Gigabit Ethernet specifications ......................................................................................... 4-75

Network management specifications ...................................................................................... 4-77

Standard SNMP MIBs ....................................................................................................... 4-77

Electromagnetic compliance ................................................................................................... 4-79

Compliance testing ........................................................................................................... 4-79

Electrical safety compliance ............................................................................................. 4-79

European Union compliance ............................................................................................. 4-80

Canada compliance ........................................................................................................... 4-80

United States compliance ................................................................................................. 4-81

Notifications ...................................................................................................................... 4-82

Radiation hazard assessment .................................................................................................. 4-83

ETSI method ..................................................................................................................... 4-83

FCC method ...................................................................................................................... 4-85

Chapter 5: Installation .............................................................................................. 5-1

Preparing for installation .......................................................................................................... 5-2

Safety precautions during installation ................................................................................ 5-2

Grounding and lightning protection requirements ............................................................. 5-2

Selecting installation options .............................................................................................. 5-2

Preparing personnel ............................................................................................................ 5-3

Preparing inventory ............................................................................................................ 5-3

Preparing tools .................................................................................................................... 5-3

Installing antennas and ODUs .................................................................................................. 5-5

Installing a direct mount antenna with one ODU ............................................................... 5-6

Installing a remote mount antenna with one ODU ........................................................... 5-10

Installing a direct mount antenna with two ODUs (via coupler) ...................................... 5-21

Installing a remote mount antenna with two ODUs (via coupler) .................................... 5-28

Installing a direct mount dual-polar antenna with two ODUs .......................................... 5-34

Installing the IF and ground cables ........................................................................................ 5-38

Page 11: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide

phn-2779_001v000 (Jul 2012) vii

Preparing IF cables ........................................................................................................... 5-40

Fitting an N type or straight TNC connector .................................................................... 5-40

Fitting a right angle TNC connector ................................................................................. 5-44

Connecting the ODU to the top LPU ................................................................................. 5-44

Weatherproofing an N type connector .............................................................................. 5-47

Hoisting the main IF cable ................................................................................................ 5-52

Installing and grounding the main IF cable ...................................................................... 5-55

Making an IF cable ground point ...................................................................................... 5-57

Installing and grounding the IF cable at building entry ................................................... 5-61

Testing the ODU and IF cable ................................................................................................. 5-63

Recommended pre-power tests ......................................................................................... 5-63

Test equipment ................................................................................................................. 5-63

Test preparation ................................................................................................................ 5-64

Testing cable loss .............................................................................................................. 5-65

Measuring distance to fault .............................................................................................. 5-68

Installing the MMU ................................................................................................................. 5-71

Mounting the MMU ........................................................................................................... 5-71

Grounding the MMU ......................................................................................................... 5-72

Connecting the MMU to the IF cable ................................................................................ 5-73

Connecting the MMU power supply ................................................................................. 5-73

Preparing network connections (1+0 and 2+0 links) ............................................................. 5-77

Installing an Ethernet data interface ................................................................................ 5-78

Installing a fiber data interface......................................................................................... 5-79

Installing a management interface ................................................................................... 5-82

Installing an E1/T1 interface ............................................................................................. 5-83

Installing an XPIC interface .............................................................................................. 5-85

Chapter 6: Configuration and alignment .................................................................... 6-1

Preparing for configuration and alignment .............................................................................. 6-2

Safety precautions during configuration and alignment .................................................... 6-2

Regulatory compliance during configuration and alignment .............................................. 6-2

Selecting configuration options .......................................................................................... 6-2

Purchasing license key ........................................................................................................ 6-2

Task 1: Connecting to the unit .................................................................................................. 6-3

Configuring the management PC ........................................................................................ 6-3

Updating the ARP table ....................................................................................................... 6-6

Connecting to the PC and powering up .............................................................................. 6-7

Logging into the web interface ........................................................................................... 6-7

Page 12: Cambium network ptp 810 series 01 00 user guide

Contents

viii phn-2779_001v000 (Jul 2012)

Logging into the CLI interface ............................................................................................ 6-9

Task 2: Configuring IP and Ethernet interfaces ..................................................................... 6-14

Configuring the IP interface ............................................................................................. 6-14

Reconnecting to the management PC ............................................................................... 6-15

Configuring Serial Port ..................................................................................................... 6-15

Configuring Ethernet payload ........................................................................................... 6-16

Configuring Ethernet network management .................................................................... 6-21

Task 3: Configuring wireless interface ................................................................................... 6-24

Viewing the configuration summary ................................................................................. 6-24

Updating link configuration .............................................................................................. 6-25

Configuring the ODU ........................................................................................................ 6-33

Configuring APC and coupler loss compensation ............................................................. 6-34

Task 4: Configuring E1/T1 interfaces ..................................................................................... 6-38

Configuring channel mapping ........................................................................................... 6-38

Configuring E1/T1 ports ................................................................................................... 6-42

Configuring E1/T1 protection switching ........................................................................... 6-45

Task 5: Configuring data orderwire ........................................................................................ 6-48

Configuring orderwire ...................................................................................................... 6-48

Task 6: Configuring protection ............................................................................................... 6-50

Configuring protection ...................................................................................................... 6-50

Task 7: Setting up SNMP agent .............................................................................................. 6-54

Configuring SNMP agent .................................................................................................. 6-54

Task 8: Configuring alarms and messages ............................................................................. 6-57

Configuring generation of diagnostics alarms .................................................................. 6-57

Configuring alarm thresholds ........................................................................................... 6-59

Task 9: Configuring syslog ...................................................................................................... 6-62

Configuring system logging (syslog) ................................................................................. 6-62

Task 10: Configuring quality of service .................................................................................. 6-63

Setting QoS priority method ............................................................................................. 6-63

Setting QoS port priorities ................................................................................................ 6-66

Setting QoS VLAN p-bit tag priorities .............................................................................. 6-68

Setting QoS DiffServ DSCP priorities ............................................................................... 6-69

Setting QoS switch priorities ............................................................................................ 6-71

Task 11: Configuring VLAN .................................................................................................... 6-73

Configuring global VLAN options ..................................................................................... 6-73

Configuring static VLANs ................................................................................................. 6-75

Configuring port based VLANs ......................................................................................... 6-77

Page 13: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide

phn-2779_001v000 (Jul 2012) ix

Example VLAN configurations .......................................................................................... 6-78

Configuring MSTPs ........................................................................................................... 6-88

Mapping VLANs to MSTP instances ................................................................................. 6-91

Task 12: LACP configuration .................................................................................................. 6-92

Configuring LACP ............................................................................................................. 6-92

Task 13: Connecting link to the network ................................................................................ 6-94

Connecting to the network ................................................................................................ 6-94

Setting the real-time clock ................................................................................................ 6-95

Task 14: Aligning antennas ..................................................................................................... 6-98

Introduction to antenna alignment ................................................................................... 6-98

Prerequisites for alignment .............................................................................................. 6-99

Aligning protected antennas ............................................................................................. 6-99

Aligning dual-polar antennas ............................................................................................ 6-99

Aligning a pair of antennas ............................................................................................. 6-100

Starting antenna alignment ............................................................................................ 6-100

Aligning antennas ........................................................................................................... 6-100

Completing alignment ..................................................................................................... 6-103

Task 15: Reviewing configuration and performance ............................................................ 6-104

Reviewing system configuration attributes..................................................................... 6-104

Monitoring link performance .......................................................................................... 6-105

Chapter 7: Operation ................................................................................................. 7-1

Web-based management ........................................................................................................... 7-2

Accessing the web interface ............................................................................................... 7-2

Layout of the web interface ................................................................................................ 7-3

Viewing the system status ................................................................................................... 7-4

Using the menu options ...................................................................................................... 7-9

Logging out ....................................................................................................................... 7-14

Managing alarms and events .................................................................................................. 7-15

Managing alarms .............................................................................................................. 7-15

Managing SNMP traps ...................................................................................................... 7-20

Managing event notification messages ............................................................................. 7-20

Disabling, enabling, muting and unmuting the ODU .............................................................. 7-21

Disabling the ODU ............................................................................................................ 7-21

Enabling the ODU ............................................................................................................. 7-22

Muting the ODU ................................................................................................................ 7-22

Unmuting the ODU ........................................................................................................... 7-22

Managing 1+1 Hot Standby links ........................................................................................... 7-23

Page 14: Cambium network ptp 810 series 01 00 user guide

Contents

x phn-2779_001v000 (Jul 2012)

Forcing protection switches .............................................................................................. 7-23

Enabling revertive and non-revertive switching ............................................................... 7-23

Enabling and disabling fault protection ............................................................................ 7-24

Selecting preferred transmitting ODU ............................................................................. 7-24

Managing 2+0 Co-Polar, Cross-Polar & XPIC links ................................................................ 7-25

GigE Master I/O operation ................................................................................................ 7-25

Standard Master I/O operation ......................................................................................... 7-26

Link outage considerations ............................................................................................... 7-26

Managing user accounts and security .................................................................................... 7-27

Creating user accounts ..................................................................................................... 7-27

Deleting user accounts ..................................................................................................... 7-28

Changing a password ........................................................................................................ 7-29

Viewing event log of MMU access .................................................................................... 7-29

Configuring HTTP (SSL) ................................................................................................... 7-30

Managing performance ........................................................................................................... 7-31

Viewing wireless link performance ................................................................................... 7-31

Viewing Ethernet switch statistics .................................................................................... 7-42

Maintaining the system ..................................................................................................... 7-50

Saving, restoring and rebooting ............................................................................................. 7-51

Saving the system configuration ....................................................................................... 7-51

Restoring the system configuration .................................................................................. 7-52

Rebooting .......................................................................................................................... 7-53

Checking the recovery version ......................................................................................... 7-53

Restoring system defaults ....................................................................................................... 7-54

Power on reset to system defaults .................................................................................... 7-54

Restore system defaults page ........................................................................................... 7-54

System default parameter values ..................................................................................... 7-55

Viewing device information .................................................................................................... 7-57

General device information ............................................................................................... 7-57

Serial number information ................................................................................................ 7-58

Device name and owner information ................................................................................ 7-58

Upgrading the system ............................................................................................................. 7-60

Entering an authorization key........................................................................................... 7-60

Installing new software versions ...................................................................................... 7-63

Removing and installing modules ........................................................................................... 7-67

Preparing to remove and install a module ........................................................................ 7-67

Removing a module ........................................................................................................... 7-68

Page 15: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide

phn-2779_001v000 (Jul 2012) xi

Installing a module ............................................................................................................ 7-69

Installing dual modem upgrade kit ................................................................................... 7-69

Software images stored on MMU modules ....................................................................... 7-70

Chapter 8: Troubleshooting ....................................................................................... 8-1

Trouble connecting to the web management interface ............................................................ 8-2

Check the MMU power supply status LED ......................................................................... 8-2

Check the DC supply to the MMU ...................................................................................... 8-2

Check the MMU status indicators ....................................................................................... 8-3

Check the NMS port Ethernet connection .......................................................................... 8-3

Check IP network connection ............................................................................................. 8-4

Check browser settings ....................................................................................................... 8-5

Using a serial port connection to set the IP address .......................................................... 8-5

Unable to access MMU using HTTPS ................................................................................. 8-6

Unable to access MMU using Telnet .................................................................................. 8-7

Unable to access MMU using SSH ..................................................................................... 8-7

Unable to access MMU using serial port ............................................................................ 8-7

Trouble establishing a wireless link .......................................................................................... 8-8

Connect to the web management interface ........................................................................ 8-8

Check for proper link configuration and connectivity ........................................................ 8-8

Transmitter status ............................................................................................................. 8-10

Antenna alignment ............................................................................................................ 8-10

Check transmit and receive frequencies ........................................................................... 8-11

Check waveguide and antennas ........................................................................................ 8-11

Check link status ............................................................................................................... 8-11

Trouble bridging Ethernet data traffic ................................................................................... 8-12

Trouble bridging E1/T1 traffic ................................................................................................ 8-15

Check for proper configuration and connectivity ............................................................. 8-15

Performing a loopback test ............................................................................................... 8-15

BERT mode ........................................................................................................................ 8-18

Trouble managing remote unit ............................................................................................... 8-20

Glossary ........................................................................................................................... I

Alarms ............................................................................................................................. V

Page 16: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide

phn-2779_001v000 (Jul 2012) xii

List of Figures

Figure 1 Typical PTP 810 deployment .......................................................................................... 1-4

Figure 2 Example of a 1+0 ring configuration .............................................................................. 1-7

Figure 3 MMU module locations ................................................................................................... 1-8

Figure 4 MMU module Power Supply Module front panel ........................................................... 1-9

Figure 5 MMU Control Module front panel ................................................................................ 1-10

Figure 6 MMU Modem Module front panel ................................................................................ 1-11

Figure 7 MMU Standard Master I/O Module front panel ........................................................... 1-13

Figure 8 MMU GigE Master I/O Module front panel .................................................................. 1-14

Figure 9 MMU additional module locations ................................................................................ 1-15

Figure 10 MMU XPIC cable linking two Modem Modules ......................................................... 1-16

Figure 11 MMU expansion I/O: 16 × E1/T1 front panel ............................................................. 1-16

Figure 12 ODU-A front view ........................................................................................................ 1-20

Figure 13 ODU-B front view ........................................................................................................ 1-20

Figure 14 ODU rear view ............................................................................................................ 1-21

Figure 15 ODU-A side view ......................................................................................................... 1-21

Figure 16 ODU-B side view ......................................................................................................... 1-22

Figure 17 Typical PTP 810 antenna with ODU (Cambium direct mount interface) .................... 1-24

Figure 18 Direct mount mechanical interface ............................................................................ 1-25

Figure 19 ODU clipped onto direct mount mechanical interface ............................................... 1-25

Figure 20 Remote mount antenna waveguide interface ............................................................. 1-25

Figure 21 RMK showing the ODU interface ................................................................................ 1-26

Figure 22 RMK showing the waveguide interface ...................................................................... 1-27

Figure 23 ODU coupler mounting kit .......................................................................................... 1-28

Figure 24 Two ODUs and antenna mounted on a coupler .......................................................... 1-28

Figure 25 Orthogonal mode transducer ...................................................................................... 1-29

Figure 26 Cable grounding kit (Cambium part number 01010419001) ..................................... 1-32

Figure 27 LPU end kit (Cambium part number WB3657) ........................................................... 1-32

Figure 28 Internal Ethernet switch for the Standard Master I/O module .................................. 1-39

Figure 29 Internal Ethernet switch for the GigE Master I/O module ......................................... 1-40

Figure 30 Internal Ethernet switch for the management network ............................................. 1-48

Figure 31 Switching of E1/T1 circuits in 1+0 and 1+1 links ...................................................... 1-59

Page 17: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide

phn-2779_001v000 (Jul 2012) xiii

Figure 32 Supported loopback tests ........................................................................................... 1-62

Figure 33 LINKPlanner profile view ............................................................................................. 2-5

Figure 34 LINKPlanner configuration and performance details ................................................... 2-6

Figure 35 LINKPlanner Bill of Materials view .............................................................................. 2-6

Figure 36 Rolling sphere method to determine the lightning protection zones ........................... 2-8

Figure 37 Grounding and lightning protection on mast or tower ............................................... 2-11

Figure 38 Grounding and lightning protection on mast or tower (protected end) ..................... 2-12

Figure 39 Grounding and lightning protection on building ........................................................ 2-13

Figure 40 Grounding and lightning protection inside high building ........................................... 2-14

Figure 41 Grounding and lightning protection inside high building (protected end) ................. 2-15

Figure 42 PTP 810 MMU Ethernet QoS Priority Queue .............................................................. 2-17

Figure 43 Schematic view of 1+0 ODU direct mount link end ................................................... 2-23

Figure 44 Schematic view of 1+0 ODU remote mount link end ................................................. 2-24

Figure 45 ODUs coupled to single direct mount antenna (schematic) ....................................... 2-26

Figure 46 ODUs coupled to single remote mount antenna (schematic) ..................................... 2-27

Figure 47 ODUs with separate direct mount antennas (schematic) ........................................... 2-28

Figure 48 ODUs with separate remote mount antennas (schematic) ......................................... 2-29

Figure 49 ODUs coupled to single direct mount antenna - co-polar links (schematic) ............... 2-32

Figure 50 ODUs coupled to a single remote mount antenna - co-polar links (schematic) .......... 2-33

Figure 51 ODUs coupled to a single direct mount antenna - cross-polar links (schematic) ....... 2-34

Figure 52 ODUs connected to a dual polar remote mount antenna - cross-polar links (schematic) ................................................................................................................................................ 2-35

Figure 53 Location of chassis serial number on MMU enclosure ............................................... 2-42

Figure 54 Locations of waveguide flanges .................................................................................... 4-9

Figure 55 Waveguide flanges – 6 GHz ........................................................................................ 4-11

Figure 56 Waveguide flanges – 7 to 15 GHz ............................................................................... 4-12

Figure 57 Waveguide flanges – 18 to 38 GHz ............................................................................. 4-13

Figure 58 Waveguide flanges – 11 GHz tapered transition ......................................................... 4-13

Figure 59 Molex LFH Matrix 50 Receptacle 100 Ω /120 Ω Balanced interface .......................... 4-19

Figure 60 Data order wire - RS-422 connector ............................................................................ 4-21

Figure 61 Data order wire - RS-232 connector ............................................................................ 4-21

Figure 62 XPIC connector (Modem module) ............................................................................... 4-21

Figure 63 ODU connector (Modem module) ............................................................................... 4-22

Figure 64 European Union compliance label .............................................................................. 4-82

Figure 65 Dual-polar antenna in remote mount configuration ................................................... 5-11

Figure 66 Words embossed on coupler ....................................................................................... 5-22

Figure 67 Correct orientation of LPUs ........................................................................................ 5-39

Page 18: Cambium network ptp 810 series 01 00 user guide

List of Figures

xiv phn-2779_001v000 (Jul 2012)

Figure 68 ODU and top LPU grounding ...................................................................................... 5-44

Figure 69 Using the hoist line ..................................................................................................... 5-54

Figure 70 IF cable grounding on a mast or tower ...................................................................... 5-55

Figure 71 Grounding at building entry ....................................................................................... 5-61

Figure 72 Example of a cable analyzer ....................................................................................... 5-64

Figure 73 Example of the cable test ........................................................................................... 5-64

Figure 74 Cable loss plot for a 14 meter cable with no ODU ..................................................... 5-66

Figure 75 Cable loss plot for a 14 meter cable with ODU connected ......................................... 5-67

Figure 76 DTF plot for a 17 meter cable with no ODU ............................................................... 5-69

Figure 77 DTF plot for a 17 meter cable with ODU connected .................................................. 5-70

Figure 78 MMU with rack mounting bracket (front mounting option shown) ............................ 5-71

Figure 79 MMU ground connector ............................................................................................. 5-72

Figure 80 MMU IF cable connector (non-standard connector shown) ....................................... 5-73

Figure 81 MMU DC power cable connector ............................................................................... 5-74

Figure 82 MMU with power cable connected ............................................................................. 5-75

Figure 83 Copper data interface connections ............................................................................. 5-78

Figure 84 Fiber data interface connections ................................................................................ 5-79

Figure 85 Management interface connections ............................................................................ 5-82

Figure 86 E1/T1 interface (RJ-48C) ............................................................................................. 5-83

Figure 87 E1/T1 interface (molex 60-pin) ................................................................................... 5-84

Figure 88 XPIC interface ............................................................................................................. 5-85

Figure 89 Starting Information page ............................................................................................ 6-8

Figure 90 CLI General Information page .................................................................................... 6-10

Figure 91 CLI Main Menu page .................................................................................................. 6-11

Figure 92 Example of a configurable CLI page ........................................................................... 6-12

Figure 93 General Network Configuration page ......................................................................... 6-14

Figure 94 Serial Configuration page ........................................................................................... 6-16

Figure 95 Ethernet Payload page for MMU Standard Master I/O module ................................. 6-17

Figure 96 Ethernet Payload page for MMU GigE Master I/O module ........................................ 6-18

Figure 97 Ethernet Payload page for MMU GigE Master I/O module with an SFP module ....... 6-19

Figure 98 Ethernet NMS page .................................................................................................... 6-22

Figure 99 Summary of Configurations page ............................................................................... 6-24

Figure 100 ODU Operational Mode page .................................................................................... 6-26

Figure 101 IDU Operational mode page ..................................................................................... 6-27

Figure 102 Payload Configuration page ...................................................................................... 6-28

Figure 103 ODU Tx Power Configuration page .......................................................................... 6-29

Figure 104 ODU Channel Selection page ................................................................................... 6-31

Page 19: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide

phn-2779_001v000 (Jul 2012) xv

Figure 105 Adaptive Coding Modulation page ............................................................................ 6-31

Figure 106 Summary of Configurations page with Redo and Update All buttons ...................... 6-33

Figure 107 ODU Tx Mute page ................................................................................................... 6-34

Figure 108 APC Configuration page ........................................................................................... 6-35

Figure 109 E1/T1 Channel Map page (pre-defined mapping) ..................................................... 6-39

Figure 110 E1/T1 Channel Map page (custom mapping) ............................................................ 6-41

Figure 111 E1/T1 Channel Map page (custom mapping updated) .............................................. 6-41

Figure 112 E1/T1 Configurations page ....................................................................................... 6-43

Figure 113 E1/T1 Protection Switching page ............................................................................. 6-45

Figure 114 Voice Orderwire Configuration ................................................................................. 6-49

Figure 115 Protection Configuration page .................................................................................. 6-50

Figure 116 Remote transmit switch algorithm ........................................................................... 6-53

Figure 117 SNMP Configuration page ........................................................................................ 6-54

Figure 118 Alarm Configuration page ......................................................................................... 6-58

Figure 119 Alarm Threshold page ............................................................................................... 6-60

Figure 120 Syslog Configuration page ........................................................................................ 6-62

Figure 121 QoS Global Configuration page (Standard Master I/O module) ............................... 6-63

Figure 122 QoS Global Configuration page (GigE Master I/O module) ...................................... 6-65

Figure 123 QoS Port Priority Map page (Standard Master I/O module) ..................................... 6-67

Figure 124 QoS Port Priority Map for GigE Master I/O module ................................................. 6-68

Figure 125 QoS VLAN p-bit Tag Priority Map page .................................................................... 6-69

Figure 126 QoS DiffServ DSCP Map page (Standard Master I/O module) ................................. 6-70

Figure 127 QoS DiffServ DSCP Priority Map for GigE Master I/O module ................................. 6-71

Figure 128 Switch Priority to Tx Priority Queue Map (GigE Master I/O module) ...................... 6-72

Figure 129 Global VLAN Configuration page .............................................................................. 6-74

Figure 130 Static VLAN Configuration ....................................................................................... 6-76

Figure 131 Add/Edit VLAN Configuration ................................................................................... 6-76

Figure 132 Port Based Forwarding Mode page .......................................................................... 6-77

Figure 133 MSTP Configuration page (when no MSTP instances exist) ..................................... 6-89

Figure 134 MSTP Configuration page (when MSTP instances exist) ........................................ 6-89

Figure 135 MSTP Instance to VLAN Map page .......................................................................... 6-91

Figure 136 LACP Configuration page ......................................................................................... 6-92

Figure 137 LACP Status page ..................................................................................................... 6-93

Figure 138 Set Data & Time page (SNTP disabled) .................................................................... 6-96

Figure 139 Set Data & Time page (SNTP enabled) ..................................................................... 6-97

Figure 140 Symmetrical relationship between voltage and alignment ..................................... 6-102

Figure 141 Typical RSSI voltage peaks and troughs ................................................................ 6-102

Page 20: Cambium network ptp 810 series 01 00 user guide

List of Figures

xvi phn-2779_001v000 (Jul 2012)

Figure 142 Summary of Configuration page ............................................................................. 6-104

Figure 143 System Administration Login page ............................................................................. 7-2

Figure 144 Web interface without status panel ............................................................................ 7-3

Figure 145 Web interface with status panel ................................................................................. 7-4

Figure 146 Status panel examples (Standard and 2+0 XPIC) ...................................................... 7-5

Figure 147 Status panel examples (Protected Non-diversity, East/East and East/West) ............. 7-6

Figure 148 Menu bar .................................................................................................................... 7-9

Figure 149 Active Alarms page ................................................................................................... 7-15

Figure 150 Alarm History page ................................................................................................... 7-18

Figure 151 ODU Configuration page .......................................................................................... 7-21

Figure 152 Add User page .......................................................................................................... 7-27

Figure 153 Delete User page ...................................................................................................... 7-28

Figure 154 Event Log page ......................................................................................................... 7-29

Figure 155 Security Configuration page ..................................................................................... 7-30

Figure 156 RSL Graph ................................................................................................................ 7-32

Figure 157 Signal Noise Ratio Graph ......................................................................................... 7-33

Figure 158 XPIC SNR Graph ....................................................................................................... 7-34

Figure 159 Tx Power Graph ........................................................................................................ 7-35

Figure 160 RF Link Performance Graph ..................................................................................... 7-36

Figure 161 Equalizer Taps Graph ............................................................................................... 7-37

Figure 162 XPIC Equalizer Taps Graph ...................................................................................... 7-38

Figure 163 Constellation Graph (256 QAM) ............................................................................... 7-39

Figure 164 XPIC Constellation Graph (256 QAM) ...................................................................... 7-40

Figure 165 Temperature Graph .................................................................................................. 7-41

Figure 166 NMS Switch Statistics page ..................................................................................... 7-42

Figure 167 Data Switch (payload port) Statistics page .............................................................. 7-44

Figure 168 Ethernet NMS – IEEE 802.1w RSTP Status page ..................................................... 7-46

Figure 169 Ethernet Payload – IEEE 802.1w RSTP page ........................................................... 7-47

Figure 170 Ethernet Payload – IEEE 802.1s MSTP page ............................................................ 7-48

Figure 171 Save/Restore Configuration page ............................................................................. 7-51

Figure 172 System Reboot page ................................................................................................. 7-53

Figure 173 Restore System Defaults page .................................................................................. 7-55

Figure 174 Device Information page ........................................................................................... 7-57

Figure 175 Serial Number Information page .............................................................................. 7-58

Figure 176 Device Names page .................................................................................................. 7-59

Figure 177 Authorization Key ..................................................................................................... 7-61

Figure 178 XPIC Authorization Key ............................................................................................ 7-62

Page 21: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide

phn-2779_001v000 (Jul 2012) xvii

Figure 179 Reprogramming page ............................................................................................... 7-64

Figure 180 MMU Modules .......................................................................................................... 7-67

Figure 181 Thumbscrew Locations ............................................................................................. 7-68

Figure 182 Threaded Hole Locations .......................................................................................... 7-68

Figure 183 Guides ....................................................................................................................... 7-69

Figure 184 Loopback page .......................................................................................................... 8-16

Figure 185 BERT Mode page ...................................................................................................... 8-19

Page 22: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide

phn-2779_001v000 (Jul 2012) xviii

List of Tables

Table 1 PTP 810 licensed bands and frequencies ......................................................................... 1-3

Table 2 ODU interfaces ............................................................................................................... 1-22

Table 3 Insertion of tags in ingress frames in double tagged mode ........................................... 1-44

Table 4 Default user accounts ..................................................................................................... 1-51

Table 5 Web-based and CLI access rights ................................................................................... 1-51

Table 6 MMU software versions ................................................................................................. 1-55

Table 7 E1/T1 port capacity ........................................................................................................ 1-58

Table 8 MMU base modules ........................................................................................................ 2-39

Table 9 MMU spare, expansion and upgrade modules ............................................................... 2-39

Table 10 MMU accessories ......................................................................................................... 2-40

Table 11 Single-step capacity upgrades (per MMU) ................................................................... 2-41

Table 12 Step-by-step capacity upgrades (per MMU) ................................................................. 2-41

Table 13 XPIC capability (per MMU) .......................................................................................... 2-42

Table 14 Selecting antennas for each hardware configuration .................................................. 2-44

Table 15 Antennas: 6 GHz single polarization ............................................................................ 2-45

Table 16 Antennas: 6 GHz dual polarization ............................................................................... 2-45

Table 17 Antennas: 7 GHz and 8 GHz single polarization .......................................................... 2-46

Table 18 Antennas: 7 GHz and 8 GHz dual polarization ............................................................. 2-46

Table 19 Antennas: 11 GHz single polarization .......................................................................... 2-47

Table 20 Antennas: 11 GHz dual polarization ............................................................................. 2-47

Table 21 Antennas: 13 GHz single polarization .......................................................................... 2-48

Table 22 Antennas: 13 GHz dual polarization ............................................................................. 2-48

Table 23 Antennas: 15 GHz single polarization .......................................................................... 2-49

Table 24 Antennas: 15 GHz dual polarization ............................................................................. 2-49

Table 25 Antennas: 18 GHz single polarization .......................................................................... 2-50

Table 26 Antennas: 18 GHz dual polarization ............................................................................. 2-50

Table 27 Antennas: 23 GHz single polarization .......................................................................... 2-51

Table 28 Antennas: 23 GHz dual polarization ............................................................................. 2-51

Table 29 Antennas: 26 GHz single polarization .......................................................................... 2-52

Table 30 Antennas: 26 GHz dual polarization ............................................................................. 2-52

Table 31 Antennas: 28 GHz single polarization .......................................................................... 2-52

Page 23: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide

phn-2779_001v000 (Jul 2012) xix

Table 32 Antennas: 28 GHz dual polarization ............................................................................. 2-52

Table 33 Antennas: 32 GHz single polarization .......................................................................... 2-53

Table 34 Antennas: 32 GHz dual polarization ............................................................................. 2-53

Table 35 Antennas: 38 GHz single polarization .......................................................................... 2-53

Table 36 Antennas: 38 GHz dual polarization ............................................................................. 2-53

Table 37 Parabolic radomes (optional) ........................................................................................ 2-54

Table 38 ODUs: Lower 6 GHz ODU-A ......................................................................................... 2-55

Table 39 ODUs: Upper 6 GHz ODU-A ......................................................................................... 2-55

Table 40 ODUs: 7 GHz ODU-A .................................................................................................... 2-56

Table 41 ODUs: 8 GHz ODU-A .................................................................................................... 2-58

Table 42 ODUs: 11 GHz ODU-B .................................................................................................. 2-59

Table 43 ODUs: 11 GHz ODU-A .................................................................................................. 2-59

Table 44 ODUs: 13 GHz ODU-A .................................................................................................. 2-60

Table 45 ODUs: 15 GHz ODU-A .................................................................................................. 2-60

Table 46 ODUs: 18 GHz ODU-B .................................................................................................. 2-61

Table 47 ODUs: 18 GHz ODU-A .................................................................................................. 2-62

Table 48 ODUs: 23 GHz ODU-B .................................................................................................. 2-62

Table 49 ODUs: 23 GHz ODU-A .................................................................................................. 2-62

Table 50 ODUs: 26 GHz ODU-A .................................................................................................. 2-63

Table 51 ODUs: 28 GHz ODU-A .................................................................................................. 2-64

Table 52 ODUs: 32 GHz ODU-A .................................................................................................. 2-64

Table 53 ODUs: 38 GHz ODU-A .................................................................................................. 2-64

Table 54 Cable and LPU components .......................................................................................... 2-65

Table 55 Inventory of the coaxial cable installation assembly kit (WB3616) .............................. 2-68

Table 56 RMKs, waveguides and accessories ............................................................................. 2-70

Table 57 Remote mounting kits ................................................................................................... 2-71

Table 58 Flexible waveguides ..................................................................................................... 2-71

Table 59 Flex-twist hanger kits available from Cambium ........................................................... 2-73

Table 60 ODU coupler mounting kits .......................................................................................... 2-73

Table 61 Orthogonal mounting kits (OMKs)................................................................................ 2-75

Table 62 Copper network cables and connectors ....................................................................... 2-75

Table 63 Fiber network cables and connectors .......................................................................... 2-76

Table 64 MMU physical specifications .......................................................................................... 4-2

Table 65 MMU environmental specifications ................................................................................ 4-2

Table 66 MMU electrical specifications ........................................................................................ 4-2

Table 67 Worst case power consumption for 1+0 link types ........................................................ 4-3

Table 68 Worst case power consumption for 1+1 link types (*1) ................................................. 4-3

Page 24: Cambium network ptp 810 series 01 00 user guide

List of Tables

xx phn-2779_001v000 (Jul 2012)

Table 69 Worst case power consumption for 2+0 link types (*1) ................................................. 4-4

Table 70 AC to DC converter specifications .................................................................................. 4-4

Table 71 ODU physical specifications ........................................................................................... 4-5

Table 72 ODU-A and ODU-B environmental specifications ........................................................... 4-5

Table 73 RSSI voltage, received signal level and bandwidth ........................................................ 4-6

Table 74 Antenna, transition, waveguide and RMK flanges ....................................................... 4-10

Table 75 Torque value in Nm (lb ft) for each fastener size ......................................................... 4-14

Table 76 ODU coupler physical specifications ............................................................................ 4-14

Table 77 ODU coupler environmental specifications .................................................................. 4-14

Table 78 ODU coupler return losses and isolation ...................................................................... 4-15

Table 79 ODU coupler insertion losses ....................................................................................... 4-15

Table 80 DC Input (power) connector (Power Supply module) .................................................... 4-16

Table 81 Ethernet 100Base-T payload connector 1-2 (Master I/O module) ................................. 4-16

Table 82 Ethernet 1000Base-T payload connector 1-4 (GigE Master I/O module) ...................... 4-17

Table 83 Gigabit Ethernet optical SFP connector (GigE Master I/O module) ............................ 4-17

Table 84 NMS 10/100Base-TX connector 1-2 (Control module) ................................................... 4-17

Table 85 Serial/Alarm port connector (Control module) ............................................................... 4-18

Table 86 E1/T1 - channels 1-2 connector (Master I/O module) .................................................... 4-18

Table 87 E1/T1 - channels 3-16 connector (Master I/O module) .................................................. 4-19

Table 88 General wireless specifications .................................................................................... 4-23

Table 89 ETSI band plan ............................................................................................................. 4-24

Table 90 FCC and IC band plan .................................................................................................. 4-25

Table 91 Cross-Reference of capacity license keys to frequency band ....................................... 4-26

Table 92 Maximum number of E1/T1 circuits with ETSI channel separations ........................... 4-27

Table 93 Maximum number of E1/T1 circuits with FCC and Canada bandwidths ..................... 4-28

Table 94 Lower 6 GHz FCC and Canada with 10 MHz bandwidth ............................................. 4-30

Table 95 Lower 6 GHz FCC and Canada with 30 MHz bandwidth ............................................. 4-30

Table 96 Lower 6 GHz FCC and Canada with 30 MHz bandwidth (XPIC) .................................. 4-30

Table 97 Lower 6 GHz ETSI with 29.65 MHz channel separation .............................................. 4-31

Table 98 Lower 6 GHz ETSI with 29.65 MHz channel separation (XPIC) .................................. 4-31

Table 99 Upper 6 GHz FCC with 10 MHz bandwidth ................................................................. 4-31

Table 100 Upper 6 GHz FCC with 30 MHz bandwidth ............................................................... 4-32

Table 101 Upper 6 GHz FCC with 30 MHz bandwidth (XPIC) .................................................... 4-32

Table 102 Upper 6 GHz ETSI with 7 MHz channel separation ................................................... 4-32

Table 103 Upper 6 GHz ETSI with 14 MHz channel separation ................................................. 4-33

Table 104 Upper 6 GHz ETSI with 30 MHz channel separation ................................................. 4-33

Table 105 Upper 6 GHz ETSI with 30 MHz channel separation (XPIC) ..................................... 4-33

Page 25: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide

phn-2779_001v000 (Jul 2012) xxi

Table 106 Upper 6 GHz ETSI with 40 MHz channel separation ................................................. 4-34

Table 107 Upper 6 GHz ETSI with 40 MHz channel separation (XPIC) ...................................... 4-34

Table 108 Upper 6 GHz ETSI with 60 MHz channel separation ................................................. 4-34

Table 109 Upper 6 GHz ETSI with 60 MHz channel separation (XPIC) ...................................... 4-35

Table 110 7 GHz ETSI with 7 MHz channel separation .............................................................. 4-35

Table 111 7 GHz ETSI with 14 MHz channel separation ............................................................ 4-35

Table 112 7 GHz ETSI with 28 MHz channel separation ............................................................ 4-36

Table 113 7 GHz ETSI with 28 MHz channel separation (XPIC) ................................................. 4-36

Table 114 8 GHz ETSI with 7 MHz channel separation .............................................................. 4-36

Table 115 8 GHz ETSI with 14 MHz channel separation ............................................................ 4-37

Table 116 8 GHz ETSI with 28 MHz channel separation ............................................................ 4-37

Table 117 8 GHz ETSI with 28 MHz channel separation (XPIC) ................................................. 4-37

Table 118 8 GHz ETSI with 29.65 MHz channel separation ....................................................... 4-38

Table 119 8 GHz ETSI with 29.65 MHz channel separation (XPIC) ............................................ 4-38

Table 120 11 GHz FCC and Canada with 10 MHz bandwidth (ODU-A) ...................................... 4-38

Table 121 11 GHz FCC and Canada with 10 MHz bandwidth (ODU-B) ...................................... 4-39

Table 122 11 GHz FCC and Canada with 30 MHz bandwidth (ODU-A) ...................................... 4-39

Table 123 11 GHz FCC and Canada with 30 MHz bandwidth (ODU-B) ...................................... 4-39

Table 124 11 GHz FCC and Canada with 30 MHz bandwidth (XPIC) (ODU-A) .......................... 4-40

Table 125 11 GHz FCC and Canada with 30 MHz bandwidth (XPIC) (ODU-B) .......................... 4-40

Table 126 11 GHz FCC and Canada with 40 MHz bandwidth (ODU-A) ...................................... 4-40

Table 127 11 GHz FCC and Canada with 40 MHz bandwidth (ODU-B) ...................................... 4-41

Table 128 11 GHz FCC and Canada with 40 MHz bandwidth (XPIC) (ODU-A) .......................... 4-41

Table 129 11 GHz FCC and Canada with 40 MHz bandwidth (XPIC) (ODU-B) .......................... 4-41

Table 130 11 GHz ETSI with 40 MHz channel separation .......................................................... 4-42

Table 131 11 GHz ETSI with 40 MHz channel separation (XPIC) ............................................... 4-42

Table 132 13 GHz ETSI with 7 MHz channel separation ............................................................ 4-42

Table 133 13 GHz ETSI with 14 MHz channel separation .......................................................... 4-43

Table 134 13 GHz ETSI with 28 MHz channel separation .......................................................... 4-43

Table 135 13 GHz ETSI with 28 MHz channel separation (XPIC) ............................................... 4-43

Table 136 15 GHz ETSI with 7 MHz channel separation ............................................................ 4-44

Table 137 15 GHz ETSI with 14 MHz channel separation .......................................................... 4-44

Table 138 15 GHz ETSI with 28 MHz channel separation .......................................................... 4-44

Table 139 15 GHz ETSI with 28 MHz channel separation (XPIC) ............................................... 4-45

Table 140 15 GHz ETSI with 56 MHz channel separation .......................................................... 4-45

Table 141 15 GHz ETSI with 56 MHz channel separation (XPIC) ............................................... 4-45

Table 142 18 GHz FCC and Canada with 10 MHz bandwidth (ODU-A) ...................................... 4-46

Page 26: Cambium network ptp 810 series 01 00 user guide

List of Tables

xxii phn-2779_001v000 (Jul 2012)

Table 143 18 GHz FCC and Canada with 10 MHz bandwidth (ODU-B) ...................................... 4-46

Table 144 18 GHz FCC and Canada with 20 MHz bandwidth (ODU-A) ...................................... 4-46

Table 145 18 GHz FCC and Canada with 20 MHz bandwidth (ODU-B) ...................................... 4-47

Table 146 18 GHz FCC and Canada with 30 MHz bandwidth (ODU-A) ...................................... 4-47

Table 147 18 GHz FCC and Canada with 30 MHz bandwidth (ODU-B) ...................................... 4-47

Table 148 18 GHz FCC and Canada with 30 MHz bandwidth (XPIC) (ODU-A) .......................... 4-48

Table 149 18 GHz FCC and Canada with 30 MHz bandwidth (XPIC) (ODU-B) .......................... 4-48

Table 150 18 GHz FCC and Canada with 40 MHz bandwidth (ODU-A) ...................................... 4-48

Table 151 18 GHz FCC and Canada with 40 MHz bandwidth (ODU-B) ...................................... 4-49

Table 152 18 GHz FCC and Canada with 40 MHz bandwidth (XPIC) (ODU-A) .......................... 4-49

Table 153 18 GHz FCC and Canada with 40 MHz bandwidth (XPIC) (ODU-B) .......................... 4-49

Table 154 18 GHz FCC and Canada with 50 MHz bandwidth (ODU-A) ...................................... 4-50

Table 155 18 GHz FCC and Canada with 50 MHz bandwidth (ODU-B) ...................................... 4-50

Table 156 18 GHz FCC and Canada with 50 MHz bandwidth (XPIC) (ODU-A) .......................... 4-50

Table 157 18 GHz FCC and Canada with 50 MHz bandwidth (XPIC) (ODU-B) .......................... 4-51

Table 158 18 GHz FCC and Canada with 80 MHz bandwidth (ODU-B) ...................................... 4-51

Table 159 18 GHz FCC and Canada with 80 MHz bandwidth (XPIC) (ODU-B) .......................... 4-51

Table 160 18 GHz ETSI with 7 MHz channel separation ............................................................ 4-52

Table 161 18 GHz ETSI with 13.75 MHz channel separation ..................................................... 4-52

Table 162 18 GHz ETSI with 27.5 MHz channel separation ....................................................... 4-52

Table 163 18 GHz ETSI with 55 MHz channel separation .......................................................... 4-53

Table 164 23 GHz FCC and Canada with 10 MHz bandwidth (ODU-A) ...................................... 4-53

Table 165 23 GHz FCC and Canada with 10 MHz bandwidth (ODU-B) ...................................... 4-54

Table 166 23 GHz FCC and Canada with 20 MHz bandwidth (ODU-A) ...................................... 4-54

Table 167 23 GHz FCC and Canada with 20 MHz bandwidth (ODU-B) ...................................... 4-54

Table 168 23 GHz FCC and Canada with 30 MHz bandwidth (ODU-A) ...................................... 4-55

Table 169 23 GHz FCC and Canada with 30 MHz bandwidth (ODU-B) ...................................... 4-55

Table 170 23 GHz FCC and Canada with 30 MHz bandwidth (XPIC) (ODU-A) .......................... 4-55

Table 171 23 GHz FCC and Canada with 30 MHz bandwidth (XPIC) (ODU-B) .......................... 4-56

Table 172 23 GHz FCC and Canada with 40 MHz bandwidth (ODU-A) ...................................... 4-56

Table 173 23 GHz FCC and Canada with 40 MHz bandwidth (ODU-B) ...................................... 4-56

Table 174 23 GHz FCC and Canada with 40 MHz bandwidth (XPIC) (ODU-A) .......................... 4-57

Table 175 23 GHz FCC and Canada with 40 MHz bandwidth (XPIC) (ODU-B) .......................... 4-57

Table 176 23 GHz FCC and Canada with 50 MHz bandwidth (ODU-A) ...................................... 4-57

Table 177 23 GHz FCC and Canada with 50 MHz bandwidth (ODU-B) ...................................... 4-58

Table 178 23 GHz FCC and Canada with 50 MHz bandwidth (XPIC) (ODU-A) .......................... 4-58

Table 179 23 GHz FCC and Canada with 50 MHz bandwidth (XPIC) (ODU-B) .......................... 4-58

Page 27: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide

phn-2779_001v000 (Jul 2012) xxiii

Table 180 23 GHz ETSI with 7 MHz channel separation ............................................................ 4-59

Table 181 23 GHz ETSI with 14 MHz channel separation .......................................................... 4-59

Table 182 23 GHz ETSI with 28 MHz channel separation .......................................................... 4-59

Table 183 23 GHz ETSI with 28 MHz channel separation (XPIC) ............................................... 4-60

Table 184 23 GHz ETSI with 56 MHz channel separation .......................................................... 4-60

Table 185 23 GHz ETSI with 56 MHz channel separation (XPIC) ............................................... 4-60

Table 186 26 GHz FCC with 10 MHz bandwidth ........................................................................ 4-61

Table 187 26 GHz FCC with 20 MHz bandwidth ........................................................................ 4-61

Table 188 26 GHz FCC with 40 MHz bandwidth ........................................................................ 4-62

Table 189 26 GHz FCC with 40 MHz bandwidth (XPIC) ............................................................. 4-62

Table 190 26 GHz ETSI with 7 MHz channel separation ............................................................ 4-62

Table 191 26 GHz ETSI with 14 MHz channel separation .......................................................... 4-63

Table 192 26 GHz ETSI with 28 MHz channel separation .......................................................... 4-63

Table 193 26 GHz ETSI with 28 MHz channel separation (XPIC) ............................................... 4-63

Table 194 26 GHz ETSI with 56 MHz channel separation .......................................................... 4-64

Table 195 26 GHz ETSI with 56 MHz channel separation (XPIC) ............................................... 4-64

Table 196 28 GHz ETSI with 7 MHz bandwidth .......................................................................... 4-65

Table 197 28 GHz ETSI with 14 MHz channel separation .......................................................... 4-65

Table 198 28 GHz ETSI with 28 MHz channel separation .......................................................... 4-65

Table 199 28 GHz ETSI with 28 MHz channel separation (XPIC) ............................................... 4-66

Table 200 28 GHz ETSI with 56 MHz channel separation .......................................................... 4-66

Table 201 28 GHz ETSI with 56 MHz channel separation (XPIC) ............................................... 4-66

Table 202 32 GHz ETSI with 7 MHz channel separation ............................................................ 4-67

Table 203 28 GHz ETSI with 14 MHz channel separation .......................................................... 4-67

Table 204 32 GHz ETSI with 28 MHz channel separation .......................................................... 4-67

Table 205 32 GHz ETSI with 28 MHz channel separation (XPIC) ............................................... 4-68

Table 206 32 GHz ETSI with 56 MHz channel separation .......................................................... 4-68

Table 207 32 GHz ETSI with 56 MHz channel separation (XPIC) ............................................... 4-68

Table 208 38 GHz FCC and Canada with 10 MHz bandwidth .................................................... 4-69

Table 209 38 GHz FCC and Canada with 50 MHz bandwidth .................................................... 4-69

Table 210 38 GHz FCC and Canada with 50 MHz bandwidth (XPIC) ......................................... 4-70

Table 211 38 GHz ETSI with 7 MHz channel separation ............................................................ 4-70

Table 212 38 GHz ETSI with 14 MHz channel separation .......................................................... 4-70

Table 213 38 GHz ETSI with 28 MHz channel separation .......................................................... 4-71

Table 214 38 GHz ETSI with 28 MHz channel separation (XPIC) ............................................... 4-71

Table 215 38 GHz ETSI with 56 MHz channel separation .......................................................... 4-71

Table 216 38 GHz ETSI with 56 MHz channel separation (XPIC) ............................................... 4-72

Page 28: Cambium network ptp 810 series 01 00 user guide

List of Tables

xxiv phn-2779_001v000 (Jul 2012)

Table 217 Fast Ethernet specifications ........................................................................................ 4-73

Table 218 Gigabit Ethernet specifications ................................................................................... 4-75

Table 219 Electrical safety specifications .................................................................................... 4-79

Table 220 PTP 810 minimum separation distances, ETSI method .............................................. 4-84

Table 221 PTP 810 minimum separation distances, FCC method (ODU) ................................... 4-86

Table 222 Tools required for PTP 810 installation ........................................................................ 5-3

Table 223 Selecting antenna and ODU installation procedures ................................................... 5-5

Table 224 Expected cable loss when ODU is not connected ....................................................... 5-67

Table 225 Default usernames and passwords ............................................................................... 6-8

Table 226 General Network Configuration attributes ................................................................ 6-15

Table 227 Ethernet Payload attributes (Spanning Tree Configuration) ..................................... 6-20

Table 228 Ethernet Payload attributes (Ethernet Port Configuration) ....................................... 6-20

Table 229 Ethernet NMS attributes (Spanning Tree Configuration) .......................................... 6-23

Table 230 Ethernet NMS attributes (Ethernet Port Configuration) ........................................... 6-23

Table 231 Step 1: Link Configuration mapping to ODU Operational Modes .............................. 6-26

Table 232 ODU Tx Power Configuration attributes .................................................................... 6-30

Table 233 APC attributes ............................................................................................................ 6-35

Table 234 Coupler loss attributes ............................................................................................... 6-37

Table 235 General purpose mappings ......................................................................................... 6-39

Table 236 Naming convention used in channel maps ................................................................. 6-40

Table 237 E1/T1 Configurations attributes ................................................................................. 6-44

Table 238 E1/T1 Protection Switching attributes ....................................................................... 6-46

Table 239 Protection Configuration attributes ........................................................................... 6-51

Table 240 SNMP Configuration attributes .................................................................................. 6-55

Table 241 Alarm Configuration attributes .................................................................................. 6-59

Table 242 Alarm Threshold attributes ........................................................................................ 6-61

Table 243 Syslog Configuration attributes ................................................................................. 6-62

Table 244 QoS Global Configuration attributes (Standard Master I/O module) ......................... 6-64

Table 245 QoS Global Configuration attributes (GigE Master I/O module) ................................ 6-66

Table 246 Global VLAN Configuration attributes ....................................................................... 6-74

Table 247 Add/Edit VLAN Configuration attributes .................................................................... 6-77

Table 248 MSTP Configuration attributes .................................................................................. 6-90

Table 249 LACP Configuration attributes ................................................................................... 6-93

Table 250 Manual clock attributes .............................................................................................. 6-96

Table 251 SNTP clock attributes ................................................................................................. 6-97

Table 252 Status panel modem and alarm status indicators ........................................................ 7-7

Table 253 Procedures performed from each menu option .......................................................... 7-10

Page 29: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide

phn-2779_001v000 (Jul 2012) xxv

Table 254 Modem card status LED ............................................................................................. 7-17

Table 255 ODU Alarms ................................................................................................................ 7-18

Table 256 XPIC Alarms ................................................................................................................ 7-19

Table 257 Add User attributes .................................................................................................... 7-27

Table 258 Security Configuration attributes ............................................................................... 7-30

Table 259 NMS Switch Statistics attributes ............................................................................... 7-43

Table 260 Data Switch (payload port) attributes ........................................................................ 7-45

Table 261 Ethernet NMS – IEEE 802.1w RSTP Status attributes ............................................... 7-46

Table 262 Ethernet Payload attributes ....................................................................................... 7-49

Table 263 MMU system default parameters ................................................................................ 7-55

Table 264 Device Information attributes .................................................................................... 7-57

Table 265 Device Names attributes ............................................................................................ 7-59

Table 266 Authorization Key attributes ...................................................................................... 7-61

Table 267 MMU software images and module storage ............................................................... 7-70

Table 268 MMU power supply status LED checks ........................................................................ 8-2

Table 269 DC supply checks when MMU power supply status LED is off or red ......................... 8-2

Table 270 MMU status indicator checks ....................................................................................... 8-3

Table 271 NMS port indicator checks ........................................................................................... 8-3

Table 272 Ping response checks ................................................................................................... 8-5

Table 273 Link configuration problems ........................................................................................ 8-8

Table 274 Loopback attributes .................................................................................................... 8-17

Table 275 BERT Mode attributes ................................................................................................ 8-19

Page 30: Cambium network ptp 810 series 01 00 user guide

List of Tables

xxvi phn-2779_001v000 (Jul 2012)

Page 31: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide

phn-2779_001v000 (Jul 2012) 1

About This User Guide

This guide describes the planning, installation and operation of the Cambium PTP 810. It is intended for use by the system designer, system installer and the system administrator.

Users of this guide should have knowledge of the following areas:

• Radio network design

• Outdoor radio equipment installation

• System installation, configuration, monitoring and fault finding

System designers should refer to the following chapters:

• Chapter 1: Product description

• Chapter 2: Planning considerations

• Chapter 3: Legal information

• Chapter 4: Reference information

Installers should refer to the following chapters:

• Chapter 5: Installation

• Chapter 6: Configuration and alignment

• Chapter 8: Troubleshooting

Operators should refer to the following chapters:

• Chapter 1: Product description

• Chapter 6: Configuration and alignment

• Chapter 7: Operation

• Chapter 8: Troubleshooting

Page 32: Cambium network ptp 810 series 01 00 user guide

General information About This User Guide

2 phn-2779_001v000 (Jul 2012)

General information

Version information

The following shows the issue status of this document:

Document issue

Date of issue

Remarks

001v000 Jul 2012 System Release 810-01-00

Contacting Cambium Networks

Support website: http://www.cambiumnetworks.com/support

Main website: http://www.cambiumnetworks.com

Sales enquiries: [email protected]

Support enquiries: [email protected]

Telephone number list: http://www.cambiumnetworks.com/contact.php

Address: Cambium Networks Limited, Linhay Business Park, Eastern Road, Ashburton, Devon, UK, TQ13 7UP

Page 33: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide General information

phn-2779_001v000 (Jul 2012) 3

Purpose

Cambium Networks Point-To-Point (PTP) documents are intended to instruct and assist personnel in the operation, installation and maintenance of the Cambium PTP equipment and ancillary devices. It is recommended that all personnel engaged in such activities be properly trained.

Cambium disclaims all liability whatsoever, implied or express, for any risk of damage, loss or reduction in system performance arising directly or indirectly out of the failure of the customer, or anyone acting on the customer's behalf, to abide by the instructions, system parameters, or recommendations made in this document.

Cross references

References to external publications are shown in italics. Other cross references, emphasized in blue text in electronic versions, are active links to the references.

This document is divided into numbered chapters that are divided into sections. Sections are not numbered, but are individually named at the top of each page, and are listed in the table of contents.

Feedback

We appreciate feedback from the users of our documents. This includes feedback on the structure, content, accuracy, or completeness of our documents. Send feedback to [email protected].

Page 34: Cambium network ptp 810 series 01 00 user guide

Problems and warranty About This User Guide

4 phn-2779_001v000 (Jul 2012)

Problems and warranty

Reporting problems

If any problems are encountered when installing or operating this equipment, follow this procedure to investigate and report:

1 Search this document and the software release notes of supported releases.

2 Visit the support website.

3 Ask for assistance from the Cambium product supplier.

4 Gather information from affected units, such as any available diagnostic downloads.

5 Escalate the problem by emailing or telephoning support.

Repair and service

If unit failure is suspected, obtain details of the Return Material Authorization (RMA) process from the support website.

Warranty

Cambium’s standard hardware warranty is for one (1) year from date of shipment from Cambium or a Cambium distributor. Cambium warrants that hardware will conform to the relevant published specifications and will be free from material defects in material and workmanship under normal use and service. Cambium shall within this time, at its own option, either repair or replace the defective product within thirty (30) days of receipt of the defective product. Repaired or replaced product will be subject to the original warranty period but not less than thirty (30) days.

To register PTP products or activate warranties, visit the support website.

For warranty assistance, contact the reseller or distributor.

Using non-Cambium parts for repair could damage the equipment or void warranty. Contact Cambium for service and repair instructions.

Page 35: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Problems and warranty

phn-2779_001v000 (Jul 2012) 5

Portions of Cambium equipment may be damaged from exposure to electrostatic discharge. Use precautions to prevent damage.

Page 36: Cambium network ptp 810 series 01 00 user guide

Security advice About This User Guide

6 phn-2779_001v000 (Jul 2012)

Security advice

Cambium Networks systems and equipment provide security parameters that can be configured by the operator based on their particular operating environment. Cambium recommends setting and using these parameters following industry recognized security practices. Security aspects to be considered are protecting the confidentiality, integrity, and availability of information and assets. Assets include the ability to communicate, information about the nature of the communications, and information about the parties involved.

In certain instances Cambium makes specific recommendations regarding security practices, however the implementation of these recommendations and final responsibility for the security of the system lies with the operator of the system.

Page 37: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Warnings, cautions, and notes

phn-2779_001v000 (Jul 2012) 7

Warnings, cautions, and notes

The following describes how warnings and cautions are used in this document and in all documents of the Cambium Networks document set.

Warnings

Warnings precede instructions that contain potentially hazardous situations. Warnings are used to alert the reader to possible hazards that could cause loss of life or physical injury. A warning has the following format:

Warning text and consequence for not following the instructions in the warning.

Cautions

Cautions precede instructions and are used when there is a possibility of damage to systems, software, or individual items of equipment within a system. However, this damage presents no danger to personnel. A caution has the following format:

Caution text and consequence for not following the instructions in the caution.

Notes

A note means that there is a possibility of an undesirable situation or provides additional information to help the reader understand a topic or concept. A note has the following format:

Note text.

Page 38: Cambium network ptp 810 series 01 00 user guide

Caring for the environment About This User Guide

8 phn-2779_001v000 (Jul 2012)

Caring for the environment

The following information describes national or regional requirements for the disposal of Cambium Networks supplied equipment and for the approved disposal of surplus packaging.

In EU countries

The following information is provided to enable regulatory compliance with the European Union (EU) directives identified and any amendments made to these directives when using Cambium equipment in EU countries.

Disposal of Cambium equipment

European Union (EU) Directive 2002/96/EC Waste Electrical and Electronic Equipment (WEEE)

Do not dispose of Cambium equipment in landfill sites. In the EU, Cambium in conjunction with a recycling partner ensures that equipment is collected and recycled according to the requirements of EU environmental law.

Disposal of surplus packaging

Do not dispose of surplus packaging in landfill sites. In the EU, it is the individual recipient’s responsibility to ensure that packaging materials are collected and recycled according to the requirements of EU environmental law.

In non-EU countries

In non-EU countries, dispose of Cambium equipment and all surplus packaging in accordance with national and regional regulations.

Page 39: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Licensing requirements

phn-2779_001v000 (Jul 2012) 9

Licensing requirements

Operating license

This equipment operates in bands that require a license in most countries.

In most countries it is illegal to operate the PTP 810 without a license from the regional or local regulating authority.

United States of America

This device has been verified by Cambium Networks as being in compliance with the requirements of the rules of the Federal Communications Commission (FCC), 47 C.F.R. Part 101, and may not be operated without a station license. In the United States such licenses are issued by the FCC to entities other than agencies of the United States government. Federal government agencies are licensed by the National Telecommunications and Information Administration (NTIA) acting upon the recommendation of the Interdepartment Radio Advisory Committee (IRAC).

Cambium license agreement

The PTP 810 must be operated in accordance with the Cambium Networks end user license agreement, as specified in Chapter 3: Legal information.

Page 40: Cambium network ptp 810 series 01 00 user guide

Licensing requirements About This User Guide

10 phn-2779_001v000 (Jul 2012)

Page 41: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide

phn-2779_001v000 (Jul 2012) 1-1

Chapter 1: Product description

This chapter provides a high level description of the PTP 810 product. It describes in general terms the function of the product, the main product variants and typical deployment. It also describes the main hardware components.

The following topics are described in this chapter:

• Overview on page 1-2 introduces the key features, typical uses, product variants and components of the PTP 810.

• Modular modem unit (MMU) on page 1-8 describes the MMU and its interfaces.

• Outdoor unit (ODU) on page 1-18 describes the ODU and its interfaces.

• Antennas and couplers on page 1-24 describes the PTP 810 antennas, couplers and remote mounting kit.

• Cabling and lightning protection on page 1-31 describes the cabling and lightning protection components of a PTP 810 installation.

• Wireless operation on page 1-34 describes how the PTP 810 wireless link is operated, including modulation modes, power control and security.

• Ethernet bridging in the customer network on page 1-38 describes how the PTP 810 bridges Ethernet data in the customer data network.

• Ethernet bridging in the management network on page 1-47 describes how the PTP 810 bridges Ethernet data in the management network.

• System management on page 1-50 introduces the PTP 810 management system, including the web interface, installation, configuration, alerts and upgrades.

• TDM bridging on page 1-57 describes PTP 810 capabilities for E1/T1 transmission over wireless links, and for switching of E1/T1 circuits within the MMU.

Page 42: Cambium network ptp 810 series 01 00 user guide

Overview Chapter 1: Product description

1-2 phn-2779_001v000 (Jul 2012)

Overview

Cambium Networks carrier-grade PTP 810 systems provide reliable, high-capacity connectivity and backhaul for Ethernet and TDM applications. The PTP 810 provides great flexibility to configure PTP systems to address a wide range of applications at affordable cost. The PTP 810 supports a number of configurations including: 1+1 hot standby, 1+1 hot standby with spatial diversity, dual 1+0, 2+0 co-polar, 2+0 cross-polar, and 2+0 XPIC.

Key features

The key features of the PTP 810 are as follows:

• Flexible indoor Modular Modem Unit (MMU) with pluggable modules that support T1/E1, and Ethernet interfaces.

• Split mount architecture, with the Outdoor Unit (ODU) mounted outdoors and the Modular Modem Unit (MMU) mounted indoors.

• Outdoor Units (ODUs) that are common to PTP 800 and PTP 810.

• Native Ethernet and TDM transmission.

• Built-in T1/E1 cross-connection switch.

• Built-in L2 Ethernet switch.

• 1+0, 1+1 Hot Standby, 1+1 Hot Standby with Spatial Diversity, 2+0 Co-Polar, 2+0 Cross Polar, 2+0 XPIC

• Support for ribbon and ring networks.

• Embedded link aggregation for 2+0 links.

• Configurable channel bandwidths from 7 MHz to 80 MHz.

• Fixed modulation modes QPSK to 256 QAM.

• Link capacity from 9 Mbps to 696 Mbps in each direction.

• Support for licensed bands from 6 GHz to 38 GHz.

• Upgradeable link capacity limits from 10 Mbps to full capacity via software authorization key.

• Optional Cross Polar Interference Cancellation (XPIC) mode.

• Effective quality of service (QoS), with Layer 2 or Layer 3 classification and four priority queues.

• Ultra-low latency, <115 us @ 332 Mbps with 64 byte frames.

• Network management (out-of-band).

• SNMP v1, v2 and v3 security.

Page 43: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Overview

phn-2779_001v000 (Jul 2012) 1-3

• Link planning with the PTP LINKPlanner.

Supported bands and frequencies

PTP 810 supports the licensed bands and frequencies listed in Table 1.

Table 1 PTP 810 licensed bands and frequencies

Licensed band Regions Frequency coverage

Lower 6 GHz FCC, IC, ETSI 5.925 – 6.425 GHz

Upper 6 GHz FCC 6.525 – 6.875 GHz

ETSI 6.425 – 7.100 GHz

7 GHz ETSI 7.110 – 7.900 GHz

8 GHz ETSI 7.725 – 8.500 GHz

11 GHz FCC, IC 10.710 – 11.690 GHz

ETSI 10.700 – 11.700 GHz

13 GHz ETSI 12.750 – 13.250 GHz

15 GHz ETSI 14.400 – 15.350 GHz

18 GHz FCC, IC, ETSI 17.700 – 19.700 GHz

23 GHz FCC, IC 21.800 – 23.600 GHz

ETSI 21.200 – 23.600 GHz

26 GHz FCC, ETSI 24.250 – 26.500 GHz

28 GHz ETSI 27.500 – 29.500 GHz

32 GHz ETSI 31.800 – 33.400 GHz

38 GHz FCC, IC 38.600 – 40.000 GHz

ETSI 37.000 – 40.000 GHz

Page 44: Cambium network ptp 810 series 01 00 user guide

Overview Chapter 1: Product description

1-4 phn-2779_001v000 (Jul 2012)

Typical users and applications

PTP 810 systems provide connectivity and backhaul for organizations such as service providers, government and public safety agencies, utilities, health care and hospitals, schools and universities, local government, transportation companies, and business enterprises.

Typical applications include:

• Leased-Line Replacement: Replace or supplement leased-line service to reduce or eliminate recurring fees.

• Video Surveillance Backhaul: Affordably and reliably backhaul video from surveillance cameras to a dispatch or command center.

• Network Redundancy: Provide network redundancy for wired or fiber networks.

• Remote Connectivity: Support teleworkers, mobile personnel and field technicians with always-on access and collaborative communications.

• Wireless Network Extensions: Connect remote locations where wired service does not exist such as on protected lands.

• Building-to-Building and Campus Connectivity: Connect between buildings or connect buildings in a campus setting.

System components

The main components of the PTP 810 are shown in Figure 1.

Figure 1 Typical PTP 810 deployment

Page 45: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Overview

phn-2779_001v000 (Jul 2012) 1-5

The main components are:

• Modular modem unit (MMU): The MMU is a flexible and modular indoor unit, providing multiple Ethernet and E1/T1 interfaces to the operator’s data network, with switching and multiplexing capabilities for operator’s data traffic. Each MMU connects to one or two Outdoor units (ODUs). A single co-axial connection between the MMU and each of the ODUs carries modulated transmit and receive signals at intermediate frequency (IF), -48 V power for the ODU, and control signals to configure and monitor the ODU.

• Outdoor unit (ODU): The ODU provides a waveguide RF interface for direct or remote connection to antennas and RF couplers. The ODU up-converts modulated IF signals from the MMU for transmission over the wireless link, and returns down-converted received wireless signals to be demodulated by the MMU.

• Antennas and couplers: Cambium supplies high performance, low profile antennas for PTP 810 frequency bands in sizes from 0.3 m (1 ft) to 3.7 m (12 ft). These can be mounted directly to the ODUs, or remotely via waveguide. In 1+1 Hot Standby and 2+0 links, ODUs installed at the same end can share an antenna through the use of coupler mounting.

• Cabling and lightning protection: The MMU is connected to ODUs using CNT-400 coaxial cable (IF cable) and lightning protection units (LPUs). MMUs, ODUs, LPUs and IF cables must all be grounded to provide optimum protection against lightning events.

The term ‘SDIDU’ appears in a number of places in the user interface. This is an alternative term for the MMU.

Link types

The PTP 810 system supports the following link types:

• 1+0: A 1+0 link is a single link with no redundancy protection. Each link end uses one ODU and one antenna. If a hardware unit or module fails, the link will be unavailable until the failed item is replaced.

• 1+1 Hot Standby: A 1+1 Hot Standby link provides protection against single point equipment failure. This is achieved by the deployment of two ODUs at each end, with two modems installed in the Modular Modem Unit at each end.

• 1+1 Hot Standby with Spatial Diversity: A 1+1 HSB SD link is identical to a 1+1 HSB link, but it uses two antennas at each end of the link to provide spatial diversity.

• 2+0 Co-Polar: A 2+0 Co-Polar configuration provides two parallel wireless links across a common path, using two RF channels with the same polarization on different frequencies. Each link end uses two ODUs and one or two antennas, and normally requires two separate operating licenses.

Page 46: Cambium network ptp 810 series 01 00 user guide

Overview Chapter 1: Product description

1-6 phn-2779_001v000 (Jul 2012)

• 2+0 Cross-Polar: A 2+0 Cross-Polar configuration is identical to the 2+0 Co-Polar configuration, except that the two parallel links are on different polarizarions (and different frequencies).

• 2+0 Cross-Polar Interference Cancellation (XPIC): A 2+0 XPIC configuration is identical to the 2+0 Cross-Polar configuration, except that the two links are on the same frequency, and cross-polar interference cancellation is enabled.

Dual 1+0 links

The PTP 810 Modular Modem Unit supports a Dual 1+0 configuration. In this configuration, a single MMU connects to two ODUs, and provides two independent 1+0 links. This configuration is useful in ring, mesh, ribbon and star networks where several links terminate at the same site.

The Dual 1+0 configuration allows Ethernet data to be forwarded between the two wireless links and the front panel Ethernet ports. It also allows E1/T1 traffic to be relayed between wireless links or terminated at front panel E1/T1 ports.

In the Dual 1+0 configuration, the MMU can be configured to provide path protection for Ethernet traffic (using RSTP) or E1/T1 traffic (using subnetwork connection protection (SNCP-like) operation). These path protection protocols are particularly useful in 1+0 ring configurations where they provide self-healing in the event of a link outage. Both the network management Ethernet traffic and the customer payload Ethernet traffic are protected in a 1+0 ring configuration using RSTP. An example of a 1+0 ring configuration for Ethernet traffic is shown in Figure 2. This protected 1+0 ring configuration works with E1/T1 traffic as well using SNCP-like operation.

Page 47: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Overview

phn-2779_001v000 (Jul 2012) 1-7

Figure 2 Example of a 1+0 ring configuration

Wireless link aggregation

The 2+0 link types can be configured to aggregate the Ethernet payload of the two wireless links. The MMU’s internal Ethernet switch load balances packets between the two radio links. This feature is only available when the MMU is fitted with the Gig-E Master I/O module. See GigE Master I/O module on page 1-13 for more details of this module.

For more information about these link types refer to:

• Planning 1+0 links on page 2-22

• Planning 1+1 links on page 2-25

• Planning 2+0 links on page 2-31

Page 48: Cambium network ptp 810 series 01 00 user guide

Modular modem unit (MMU) Chapter 1: Product description

1-8 phn-2779_001v000 (Jul 2012)

Modular modem unit (MMU)

This section describes the PTP 810 MMU, its main capabilities and its interfaces.

MMU description

The PTP 810 modular modem unit (MMU) is a flexible and modular indoor unit, providing multiple Ethernet and E1/T1 interfaces to one or more data networks, with internal switching and multiplexing capabilities for data traffic.

Required modules

Every MMU configuration requires, as a minimum, four modules for a basic 1+0 configuration:

• Power Supply Module

• Control Module

• Modem Module

• Master I/O Module, selected from the following options:

o Standard Master I/O Module

o GigE Master I/O Module

The module locations are shown in Figure 3.

Figure 3 MMU module locations

Power Supply Module

The Power Supply Module provides an interface between the MMU and an external DC power supply, and provides low voltage supplies used by the remaining MMU modules.

Page 49: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Modular modem unit (MMU)

phn-2779_001v000 (Jul 2012) 1-9

The Power Supply Module front panel is shown in Figure 4.

Figure 4 MMU module Power Supply Module front panel

DC power input

The MMU requires an input voltage of –41 V dc to –60 V dc at the front panel DC Input connector. The MMU then supplies power to the rest of the PTP 810 system including the ODUs. The power dissipation of the complete PTP 810 is dependent on the specific configuration. Details are given in MMU specifications on page 4-2.

The MMU front panel power connector pin numbering is as follows:

• Pin 1 (RET): Power supply return.

• Pin 2 (–48V): Nominal –48 V dc input.

The power supply may be isolated from ground (in which case, the return side will be connected to ground via a diode in the MMU), or the return side may be connected to ground externally.

The MMU is protected against reverse polarity for a ground-isolated power supply.

The power supply, the MMU or the ODU may be damaged if a ground-referenced power supply is connected with reverse polarity. Avoid connecting +48 V dc to Pin 2 if Pin 1 is connected to ground.

The MMU supplies the ODU with all required power via the IF cable.

The DC current drawn by the MMU is specified, for various configurations, in MMU specifications on page 4-2.

DC power connector and wiring

A mating power cable connector is supplied with the MMU. It is a 2-pin plug, 5 mm pitch, manufactured by Phoenix Contact, P/N 17 86 83 1 (connector type MSTB 2,5/2-STF). This connector has screw clamp terminals that accommodate 24 AWG to 12 AWG wire. Select the power cable wire to provide the appropriate current with minimal voltage drop, based on the power supply voltage and length of cable required. The recommended wire size for power cables under 3.1 m (10 feet) in length supplying –48 V dc is 18 AWG.

Page 50: Cambium network ptp 810 series 01 00 user guide

Modular modem unit (MMU) Chapter 1: Product description

1-10 phn-2779_001v000 (Jul 2012)

The MMU does not have a power on/off switch. When DC power is connected to the MMU, the digital radio powers up and is operational. By default the ODU(s) are muted and will not radiate RF power until the MMU is configured using the Link Configuration Wizard. Once the MMU is configured, the antenna should be directed safely before power is applied.

Control Module

The Control Module (Figure 5) hosts the MMU network management agent. The network management agent supports a single IP interface with HTTP, HTTPS, Telnet, SSH, and SNMP protocols. The MMU provides network management access to the management agent using two copper Ethernet ports on the Control Module front panel. The Control Module additionally provides a serial console interface, and alarm inputs and outputs. The Control Module can be removed/replaced without affecting service.

Figure 5 MMU Control Module front panel

Control Module interfaces

The Control Module provides the following external interfaces:

• NMS 10/100 Port 1: Access to the network management agent for HTTP, HTTPS, Telnet, SSH, and SNMP using 10BASE-T and 100BASE-TX Ethernet interfaces.

• NMS 10/100 Port 2: Similar to Port 1.

• Serial/Alarm: Serial console, two Form-C relay alarm outputs, two TTL alarm outputs, four TTL alarm inputs on a DB-15HD female connector.

• USB: Not used at present.

• Ground terminal: One of two possible ground connections for the MMU.

Control Module status indicator

The Status indicator is the primary front panel indicator for the status of the MMU. Alarm codes are indicated by means of patterns of flashes. The alarm codes are listed in Alarms on page V.

Page 51: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Modular modem unit (MMU)

phn-2779_001v000 (Jul 2012) 1-11

Command line interface

In addition to web-based management and SNMP, the MMU provides a command line interface (CLI) for network management via Telnet or SSH (over Ethernet), or via a serial data interface.

The serial interface provides a convenient means to configure the IP interface if the existing IP address is unknown or unreachable.

Alarm assignments

External alarm inputs can be reported to the network management system. Any of the alarm conditions can be mapped to the external alarm outputs.

Modem Module

The Modem Module (Figure 6) provides the external interface with one ODU using a single co-axial connection.

The Modem Module has the following functions:

• Modulator: Generates a modulated IF signal at 350 MHz ready for frequency up-conversion and amplification by the ODU.

• Demodulator: Receives a modulated IF signal at 140 MHz from the ODU.

• DC power: Provides power to the ODU at nominal –48 V dc

• Control and monitoring of the ODU

Figure 6 MMU Modem Module front panel

Modem Module interfaces

The Modem Module provides the following interfaces:

• ODU: Connects the IF cable using a 50 Ω TNC connector.

• XPIC: Connects to a second Modem Module for use in the 2+0 XPIC link type. See Additional Modem Module on page 1-15 for further details.

Page 52: Cambium network ptp 810 series 01 00 user guide

Modular modem unit (MMU) Chapter 1: Product description

1-12 phn-2779_001v000 (Jul 2012)

Modem Module status indicator

The Modem Module status indicator has the following states:

• Green: The wireless link is locked and the modem is active.

• Orange: The wireless link is locked and the modem is in standby for a 1+1 Hot Standby link.

• Flashing Green: Low signal-to-noise ratio (SNR).

• Flashing Orange: The wireless link is unlocked.

• Flashing Red: ODU –48V power is disabled.

• Red: May occur in the following conditions:

o ODU Power Fault. Occurs when the –48 V to the Modem Module is low or excessive current is being drawn from the –48 V. In either case, the –48 V will be disabled by the hardware.

o Modem Hardware Fault. Occurs when any of the power-on self tests failed or IF Power Fault or Digital Power Fault detected during normal operation.

‘Locked’ means that the link is established (up).

‘Unlocked’ means that the link is not established (down).

Standard Master I/O module

The Standard Master I/O module (Figure 7) provides the external interface with the Ethernet and TDM network. This module supports connection to an Ethernet data network using one or two Fast Ethernet (100BASE-TX) ports, and to a TDM network using up to 16 T1 or E1 circuits.

In addition, the Standard Master I/O module supports the following functions:

• QoS

• VLAN bridging

• 1+1 protection switching

• Ethernet spanning tree convergence using rapid spanning tree protocol (RSTP)

• TDM switching

• Data orderwire

• Port mapping

Page 53: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Modular modem unit (MMU)

phn-2779_001v000 (Jul 2012) 1-13

Figure 7 MMU Standard Master I/O Module front panel

Standard Master I/O Module external interfaces

The Standard Master I/O module provides the following individual external interfaces:

• User 10/100 Port 1: RJ-45 connector, auto-negotiation. Connection to the customer data network switch using 10BASE-T and 100BASE-TX Ethernet interfaces.

• User 10/100 Port 2: Same as User 10/100 Port 1.

• E1/T1 Port 1: Connection to the customer TDM network via E1 (120 Ω balanced) or T1 (100 Ω balanced) using an RJ-48C connector.

• E1/T1 Port 2: Same as E1/T1 Port 1.

• E1/T1 Ports 3 to 16: Fourteen E1/T1 circuits connected via a single 60-pin Molex connector.

• Aux (Data Orderwire): A serial data channel available for control of external equipment using RJ-45 connector supporting RS-422 up to 64 kbps or RS-232 up to 19.2 kbps.

• Ground terminal: One of two possible ground connections for the MMU.

• Call button: Not used.

GigE Master I/O module

The GigE Master I/O module (Figure 8) provides the external interface with the Ethernet and TDM data network. This module supports connection to an Ethernet data network using a copper or fiber Gigabit Ethernet port (using an optional SFP module), one to four copper Gigabit Ethernet (1000BASE-T) ports, and to a TDM network using one or two T1 or E1 circuits.

In addition, the GigE Master I/O module supports the following functions:

• VLAN bridging

• 1+1 protection switching

• Ethernet spanning tree convergence using using rapid spanning tree protocol (RSTP)

• TDM cross-point switching

• Data orderwire

• Transparent aggregation for 2+0 link types

Page 54: Cambium network ptp 810 series 01 00 user guide

Modular modem unit (MMU) Chapter 1: Product description

1-14 phn-2779_001v000 (Jul 2012)

Figure 8 MMU GigE Master I/O Module front panel

GigE Master I/O Module external interfaces

The GigE Master I/O module provides the following individual external interfaces:

• SFP: Connection to the customer data network by a copper or fiber Ethernet interface using an optional SFP module.

• User 10/100/1000 Port 1: RJ45 connection to the customer data network using 10BASE-T, 100BASE-TX and 1000BASE-TX Ethernet interfaces.

• User 10/100/1000 Port 2, 3, 4: Same as User 10/100/1000 Port 1.

• Aux (Data Orderwire): RJ-45 connector supporting RS-422 up to 64 kbps or RS-232 up to 19.2 kbps.

• E1/T1 Port 1: Connection to the customer TDM network via E1 (120 Ω balanced) or T1 (100 Ω balanced) using an RJ-48C connector.

• E1/T1 Port 2: Same as E1/T1 Port 1.

• Ground terminal: One of two possible ground connections for the MMU.

Jumbo frame support

The GigE Master I/O Module supports jumbo-sized Ethernet frames up to 9728 octets (4000 Bytes for the SNCP-like version).

Additional modules

The modular construction of the MMU accepts the following additional or optional modules:

• Additional Power Supply Module

• Additional Modem Module

• Expansion I/O: 16 × E1/T1

• The module locations are shown in Figure 9.

Page 55: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Modular modem unit (MMU)

phn-2779_001v000 (Jul 2012) 1-15

Figure 9 MMU additional module locations

Additional Power Supply Module

The additional Power Supply Module provides hardware redundancy. An MMU with two Power Supply Modules will remain in operation following a failure of either module. For additional protection, the two Power Supply Modules may be connected to two independent –48 V supplies.

The addition of an extra power supply module does not provide higher power to the PTP 810.

Additional Modem Module

The additional Modem Module is required for the following link types:

• Dual 1+0

• 1+1 Hot Standby

• 1+1 Hot Standby with Spatial Diversity

• 2+0 Co-Polar

• 2+0 Cross-Polar

• 2+0 Cross-Polar Interference Cancellation (XPIC)

Page 56: Cambium network ptp 810 series 01 00 user guide

Modular modem unit (MMU) Chapter 1: Product description

1-16 phn-2779_001v000 (Jul 2012)

XPIC cable

In the 2+0 XPIC configuration, the two Modem Modules must be linked using the PTP 810 XPIC Cable for operation (Figure 10). The XPIC cable exchanges digital IF signals between the horizontal and vertical polarization modems to cancel cross-polar interference.

Figure 10 MMU XPIC cable linking two Modem Modules

Expansion I/O: 16 × E1/T1

The Expansion I/O: 16 × E1/T1 module provides additional connections to a TDM data network (Figure 11). This module supports up to 16 T1 or E1 circuits.

The Expansion I/O can be used in conjunction with the Standard Master I/O to provide a total of 32 E1/T1 circuits, or with the GigE Master I/O to provide a total of 18 E1/T1 circuits.

Figure 11 MMU expansion I/O: 16 × E1/T1 front panel

Page 57: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Modular modem unit (MMU)

phn-2779_001v000 (Jul 2012) 1-17

Expansion I/O: 16 × E1/T1 external interfaces

The Expansion I/O: 16 × E1/T1 module provides the following individual external interfaces:

• E1/T1 Port 1: Connection to the customer TDM network via E1 (120 Ω balanced) or T1 (100 Ω balanced) using an RJ-48C connector.

• E1/T1 Port 2: Similar to Port 1.

• E1/T1 Ports 3 to 16: Fourteen E1/T1 circuits connected via a single 60-pin Molex connector.

Further reading on the MMU

For more information on the MMU, refer to the following:

• Ordering MMUs on page 2-39 describes how to order MMUs for the link and specifies the Cambium part number of the MMU kit.

• MMU specifications on page 4-2 contains specifications of the MMU, such as dimensions, weight and environmental requirements.

• Installing the MMU on page 5-71 describes how to install and connect the MMU.

• Preparing network connections (1+0 and 2+0 links) on page 5-77 describes how to prepare the MMU network connections for unprotected links.

• Connecting to the network on page 6-94 describes how to complete and test the MMU network connections.

Page 58: Cambium network ptp 810 series 01 00 user guide

Outdoor unit (ODU) Chapter 1: Product description

1-18 phn-2779_001v000 (Jul 2012)

Outdoor unit (ODU)

This section describes the ODU and its interfaces.

The PTP 810 Series and PTP 800 Series support an identical set of ODUs.

ODU description

The outdoor unit (ODU) provides the necessary frequency conversion and amplification of signals which pass between the MMU and antenna.

In the transmit direction, the ODU takes the fixed intermediate frequency (IF) signal provided by the MMU and converts and amplifies it to a configured licensed band radio frequency signal for transmission at the antenna. In the receive direction, the ODU provides amplification and down conversion of a licensed band signal received at the antenna interface. The result is a fixed IF signal which is passed to the MMU for demodulation.

ODUs are available in all licensed bands supported by PTP 810 (see Supported bands and frequencies on page 1-3 for the full list of supported bands). A given licensed band is generally split into sub-bands where a given sub-band is supported by a pair of ODUs. One ODU is designed to transmit at the high frequency side of the Frequency Division Duplex (FDD), the other at the low frequency side. The ODU transmit and receive frequencies are configurable within a sub-band.

The ODU is designed for outdoor operation, either mounting directly to the back of an antenna or mounted separately using a Remote Mount Kit which then connects to the antenna with flexible waveguide.

The ODU also provides an interface which allows the installer to monitor the receive signal level when aligning antennas.

Page 59: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Outdoor unit (ODU)

phn-2779_001v000 (Jul 2012) 1-19

Alternative ODU platforms

There are two alternative ODU platforms: ODU-A and ODU-B. The platform can be identified from the label.

ODU-A is available in all bands, whereas ODU-B is only available in selected regions and bands. ODU-B is the preferred choice when available, as it offers the following advantages over ODU-A: higher transmit power and lower power dissipation.

Do not install an ODU-A and an ODU-B in the same link.

For more information about the capabilities and availability of ODU-A and ODU-B, refer to Ordering ODUs on page 2-54.

The term ‘ODU’ covers both ODU-A and ODU-B.

ODU interfaces

The ODU interfaces are illustrated in: Figure 12, Figure 13, Figure 14, Figure 15 and Figure 16. They are described in Table 2.

Page 60: Cambium network ptp 810 series 01 00 user guide

Outdoor unit (ODU) Chapter 1: Product description

1-20 phn-2779_001v000 (Jul 2012)

Figure 12 ODU-A front view

Figure 13 ODU-B front view

Page 61: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Outdoor unit (ODU)

phn-2779_001v000 (Jul 2012) 1-21

Figure 14 ODU rear view

Figure 15 ODU-A side view

Page 62: Cambium network ptp 810 series 01 00 user guide

Outdoor unit (ODU) Chapter 1: Product description

1-22 phn-2779_001v000 (Jul 2012)

Figure 16 ODU-B side view

Table 2 ODU interfaces

# Interface Function

1 Waveguide polarization arrow

This indicates the orientation of the waveguide interface. The arrow is parallel to the short dimension of the rectangular waveguide aperture.

2 Spring loaded latches These four spring loaded latches are used to fasten the ODU to the antenna, remote mounting kit or coupler.

3 Waveguide interface This connects to a Cambium direct mount antenna, an ODU coupler kit, or a remote mounting kit.

4 Ground connector This is used to ground the ODU to the top lightning protection unit (LPU).

5 RSSI connector The received signal strength indication (RSSI) connector is a standard BNC female connector that provides access to an analogue voltage proportional to the received power at the ODU input. A voltmeter is attached to the RSSI connector to measure the voltage when aligning the antenna. For more information, see Aligning antennas on page 6-100.

6 MMU connector This connects the ODU to the MMU via an IF cable.

Page 63: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Outdoor unit (ODU)

phn-2779_001v000 (Jul 2012) 1-23

Further reading on the ODU

For more information on the ODU, refer to the following:

• Grounding and lightning protection on page 2-7 describes the grounding and lightning protection requirements of a PTP 810 installation, including the ODU.

• Ordering ODUs on page 2-54 lists the ODUs available for PTP 810 installations, with Cambium part numbers.

• ODU specifications on page 4-5 contains specifications of the ODU, such as dimensions, weight and environmental requirements.

• Coupler mounting kit specifications on page 4-14 contains specifications of the couplers that may be used to connect two ODUs to one antenna.

• Installing antennas and ODUs on page 5-5 describes how to install the antennas, ODUs and waveguide connections at each link end, either in a direct mount or remote mount configuration, with or without couplers.

Page 64: Cambium network ptp 810 series 01 00 user guide

Antennas and couplers Chapter 1: Product description

1-24 phn-2779_001v000 (Jul 2012)

Antennas and couplers

This section describes the PTP 810 antennas, couplers and remote mounting kit.

Antennas

A typical antenna is shown in Figure 17.

Figure 17 Typical PTP 810 antenna with ODU (Cambium direct mount interface)

Antenna diameter

In each band, the antennas are provided in a number of diameters, the larger the diameter, the greater the gain.

Antenna interface

There are two types of antennas providing different interfaces to the ODU:

• Direct mount interface: The ODU mounts directly to the back of the antenna (Figure 18) and is secured using the integral spring loaded latches (Figure 19).

• Waveguide interface: The antenna connects to the ODU via a waveguide (Figure 20). The ODU is mounted separately from the antenna.

Page 65: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Antennas and couplers

phn-2779_001v000 (Jul 2012) 1-25

Figure 18 Direct mount mechanical interface

Figure 19 ODU clipped onto direct mount mechanical interface

Figure 20 Remote mount antenna waveguide interface

Page 66: Cambium network ptp 810 series 01 00 user guide

Antennas and couplers Chapter 1: Product description

1-26 phn-2779_001v000 (Jul 2012)

Antenna polarization

Antennas can be provided as single polar or dual polar:

• Single polar : A single polar antenna provides a single interface to the ODU. The antennas are normally supplied with vertical polarization. For horizontal polarization, the antennas can be modified by the user using the instructions provided. Single polar antennas can be provided with a direct mount interface or a waveguide interface.

• Dual polar: Dual polar antennas provide two interfaces, one with vertical polarization and one with horizontal polarization. This allows two links connecting the same two sites to share antennas, the two links operating on opposite polarizations. Dual Polar antennas provide a waveguide interface only.

Remote mounting kits (RMKs)

An RMK is used in a remote mount configuration to connect the ODU (or coupler) to the antenna via a flexible waveguide. Direct mount configurations do not require RMKs. The RMK has the following features:

• A clamp for attaching the RMK to a mounting pole.

• A cylindrical transition (Figure 21) onto which the ODU mounts.

• A waveguide interface transition (Figure 22) for connection to the antenna via a flexible waveguide.

The choice of RMK depends upon the frequency variant. The 11 GHz RMK is always used with a tapered transition between the antenna and the flexible waveguide.

Figure 21 RMK showing the ODU interface

Page 67: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Antennas and couplers

phn-2779_001v000 (Jul 2012) 1-27

Figure 22 RMK showing the waveguide interface

Coupler mounting kits

The signals from two ODUs can be coupled to a single antenna. The ODUs mount directly to the coupler (Figure 23) which then provides an interface to the antenna which is identical to that of an ODU. The coupler can mount directly to the back of a direct mount interface antenna (Figure 24), or it can be mounted separately using the remote mounting kit (RMK).

There are two types of coupler:

• Symmetric coupler: The symmetric coupler splits the power evenly between the two ODUs. A nominal 3 dB is lost in each arm of the coupler. Symmetric couplers are required in 2+0 Co-Polar links. They may also be deployed in 1+1 Hot Standby links if asymmetric couplers would cause excessive loss.

• Asymmetric coupler: The asymmetric coupler splits the power in a way which favours one ODU. A nominal 1 dB is lost in the Main arm of the coupler with a nominal 7 dB being lost in the other arm. This is often a preferred option for 1+1 Hot Standby links (see Link types on page 1-5).

Couplers increase system loss.

The choice of coupler mounting kit depends on the frequency variant and on the coupler type required (symmetric or asymmetric).

Page 68: Cambium network ptp 810 series 01 00 user guide

Antennas and couplers Chapter 1: Product description

1-28 phn-2779_001v000 (Jul 2012)

Figure 23 ODU coupler mounting kit

Figure 24 Two ODUs and antenna mounted on a coupler

Page 69: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Antennas and couplers

phn-2779_001v000 (Jul 2012) 1-29

Direct mount dual-polar antennas

Direct mount dual-polar antennas are only used in 2+0 cross-polar and 2+0 XPIC direct mount configurations. They are supplied with an orthogonal mode transducer (Figure 25) with transitions (vertical and horizontal) that allow two ODUs to be coupled to the antenna.

Cambium supply dual-polar direct mount antennas as listed in Ordering antennas on page 2-44.

However, if a previously purchased antenna is to be upgraded to support a 2+0 cross-polar direct mount configuration, Cambium can supply separate orthogonal mount kits (OMKs), as listed in Ordering OMKs on page 2-75. The OMK can only be fitted to an antenna that is in the same band, for example, a 6 GHz antenna can only accept a 6 GHz OMK.

Figure 25 Orthogonal mode transducer

Page 70: Cambium network ptp 810 series 01 00 user guide

Antennas and couplers Chapter 1: Product description

1-30 phn-2779_001v000 (Jul 2012)

Further reading on antennas and couplers

For more information on antennas and antenna accessories, refer to the following:

• Site selection on page 2-3 describes how to select a site for the antenna.

• Grounding and lightning protection on page 2-7 describes the grounding and lightning protection requirements of a PTP 810 installation, including the antenna.

• Ordering antennas on page 2-44 lists the antennas required for PTP 810 installations, with Cambium part numbers.

• Ordering RMKs and waveguides on page 2-70 lists the RMKs, waveguides, hangers and transitions required for PTP 810 installations, with Cambium part numbers.

• Ordering coupler mounting kits on page 2-73 lists the couplers required for PTP 810 installations, with Cambium part numbers.

• Ordering OMKs on page 2-75 lists the OMKs required for PTP 810 installations, with Cambium part numbers.

• Equipment specifications on page 4-2 contains specifications of the flexible waveguides and couplers.

• Installing antennas and ODUs on page 5-5 describes how to install the antennas, ODUs and waveguide connections at each link end, either in a direct mount or remote mount configuration, with or without couplers.

• Task 14: Aligning antennas on page 6-98 describes how to align the two antennas in a link.

Page 71: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Cabling and lightning protection

phn-2779_001v000 (Jul 2012) 1-31

Cabling and lightning protection

This section describes the cabling and lightning protection components of a PTP 810 installation.

Lightning protection

The PTP 810 has been tested for compliance to the EMC immunity specifications identified in European Union compliance on page 4-80.

The ODUs are fitted with surge limiting circuits and other features to minimize the risk of damage due to nearby lightning strikes. To be fully effective, these standard features require some additional equipment to be configured as part of the system installation.

The PTP 810 Series is not designed to survive direct lightning strikes. For this reason the antenna and ODU should not be installed at the highest point in a localized area. See Grounding and lightning protection on page 2-7.

ODU to MMU connections

The ODU is connected to the LPUs and MMU using CNT-400 coaxial cable (IF cable).

MMU to network connections

The MMU is connected to network equipment using either a copper data port (100baseT or 1000baseT Ethernet) or a fiber interface (1000BaseSX or 1000BaseLX).

Cable grounding

The ODU, LPUs and IF cable must be grounded to the supporting structure at the points specified in Grounding and lightning protection on page 2-7. One cable grounding kit for 1/4" and 3/8" cable (Figure 26) is required at each grounding point.

Page 72: Cambium network ptp 810 series 01 00 user guide

Cabling and lightning protection Chapter 1: Product description

1-32 phn-2779_001v000 (Jul 2012)

Figure 26 Cable grounding kit (Cambium part number 01010419001)

Lightning protection units (LPUs)

The LPU end kit (Figure 27) is required for IF cables. One LPU is installed next to the ODU and the other is installed near the building entry point.

Figure 27 LPU end kit (Cambium part number WB3657)

Page 73: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Cabling and lightning protection

phn-2779_001v000 (Jul 2012) 1-33

Further reading on cabling and lightning protection

For more information on cabling and lightning protection, refer to the following:

• Maximum IF cable length on page 2-3 gives the maximum permitted lengths of IF cables in PTP 810 installations.

• Grounding and lightning protection on page 2-7 describes the grounding and lightning protection requirements of a PTP 810 installation.

• Ordering IF cable, grounding and LPUs on page 2-65 lists the cables, connectors, grounding kits and LPUs required for PTP 810 installations.

• Installing the IF and ground cables on page 5-38 describes how to install the IF cables and how to install grounding and lightning protection.

Page 74: Cambium network ptp 810 series 01 00 user guide

Wireless operation Chapter 1: Product description

1-34 phn-2779_001v000 (Jul 2012)

Wireless operation

This section gives an overview of the key wireless features supported by PTP 810, including channel separation, bandwidth, modulation modes and transmit power control.

Channel separation

The PTP 810 wireless link supports the following channel separations:

• 7 MHz

• 10 MHz

• 13.75 MHz

• 14 MHz

• 20 MHz

• 27.5 MHz

• 28 MHz

• 29.65 MHz

• 30 MHz

• 40 MHz

• 50 MHz

• 55 MHz

• 56 MHz

• 80 MHz.

The available selection of channel separations varies depending on capacity key, band and region.

Channel bandwidth

The PTP 810 wireless link supports the following channel bandwidths:

• 7 MHz

• 10 MHz

• 14 MHz

• 20 MHz

• 28 MHz

• 30 MHz

Page 75: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Wireless operation

phn-2779_001v000 (Jul 2012) 1-35

• 40 MHz

• 50 MHz

• 56 MHz

The available selection of channel bandwidths varies depending on capacity key, band and region.

Modulation modes

The PTP 810 wireless link operates using single carrier modulation with the following fixed modulation modes:

• QPSK

• 16QAM

• 32QAM

• 64QAM

• 128QAM

• 256QAM

The available selection of modulation modes varies depending on capacity key, band, region and channel bandwidth.

PTP 810 provides forward error correction (FEC) coding for data transmitted over the wirless link. The error correction coding consists of an inner convolutional code concatenated with an outer Reed-Solomon code. The overall FEC code rate in PTP 810 varies between 0.81 and 0.89 depending on channel bandwidth and modulation mode.

For more information, see Capacity, transmit power and sensitivity on page 4-29.

Adaptive power control

PTP 810 provides closed-loop adaptive power control (APC). APC ensures that transmitters will operate at the minimum level needed for error-free operation of the link. It achieves this by modifying the transmit power in order to maintain a bit error rate (before error correction) between a lower and upper threshold as measured at the remote end of the link.

Adaptive operation of the transmitter power can be enabled or disabled using the Adaptive Power Control attribute on the APC Configuration page of the web-based interface. This attribute must have the same setting at both ends of the link. In some regions, automatic transmitter power control is a regulatory requirement; in these cases, APC must not be disabled.

Page 76: Cambium network ptp 810 series 01 00 user guide

Wireless operation Chapter 1: Product description

1-36 phn-2779_001v000 (Jul 2012)

APC is not available in the 2+0 XPIC link type.

Maximum receive power

The maximum receive power is the maximum power at which a PTP 810 link should be operated to maintain error free communication. This maximum receive power for normal operation is -35 dBm.

On very short links it may be necessary to use a fixed waveguide attenuator, which will require the use of a remote mount antenna, to keep the maximum receive power at an acceptable level.

Maximum transmit power

Maximum transmit power is the maximum power that the PTP 810 is permitted to generate at the waveguide interface assuming that APC is disabled. The equipment limit for maximum transmit power is defined by modulation mode, band, channel bandwidth and standards body or region. The spectrum license limit is determined by the maximum EIRP permitted by the individual license, the antenna gain and feeder loss. The maximum transmit power that can be configured for PTP 810 is limited by the more restrictive of the equipment limit and the spectrum license limit.

XPIC

PTP 810 systems support XPIC functionality in 64, 128 and 256 QAM modulation modes at 28 MHz or above channel bandwidths. XPIC allows the doubling of throughput without increasing channel bandwidth. To accomplish this, different data is transmitted simultaneously on the horizontal and vertical polarizations in the same channel.

For an XPIC link, the PTP 810 MMU must be configured as a dual modem. One XPIC cable is required to inter-connect the two modem modules of each MMU. To enable XPIC, an XPIC license key needs to be purchased. Two XPIC license keys are required per XPIC link; one key per MMU. The serial numbers of the MMU chassis and of each of the modem modules are needed to purchase an XPIC license. These serial numbers are found on either the packing sheet or the GUI using the Serial Number Information command (see Viewing device information on page 7-57.

Page 77: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Wireless operation

phn-2779_001v000 (Jul 2012) 1-37

Further reading on wireless operation

For more information on wireless operation, refer to the following:

• Link planning on page 2-2 describes factors to be taken into account when planning links, and introduces PTP LINKPlanner.

• Wireless specifications on page 4-23 contains specifications of the PTP 810 wireless interface, such as RF bands, channel width, spectrum settings, maximum power and sensitivity.

• Electromagnetic compliance on page 4-79 describes how the PTP 810 complies with the radio regulations that are in force in various countries.

• Task 3: Configuring wireless interface on page 6-24 describes how to configure the wireless interface using the installation wizard.

• Monitoring link performance on page 6-105 describes how to check that a newly installed link is achieving predicted levels of performance.

• Disabling, enabling, muting and unmuting the ODU on page 7-21 describes how to control wireless transmission by disabling, enabling, muting and unmuting the ODU.

• Managing performance on page 7-31 describes how to manage the performance of a PTP 810 link.

Page 78: Cambium network ptp 810 series 01 00 user guide

Ethernet bridging in the customer network Chapter 1: Product description

1-38 phn-2779_001v000 (Jul 2012)

Ethernet bridging in the customer network

This section describes how the PTP 810 bridges Ethernet data in the customer data network.

Transparent Ethernet service

The PTP 810 system provides a transparent bridging Ethernet service between data ports at a local MMU and data ports at an associated remote MMU. The Ethernet service is based on conventional layer two transparent bridging, similar to the operation of conventional wired Ethernet bridges or switches. Ethernet bridging in PTP 810 is transparent to all frame types, including MPLS frames, except for specific Layer 2 Control Protocol frames listed below.

Layer two control protocols

The PTP 810 system is transparent to the following layer two control protocols (L2CPs):

• Link OAM, IEEE 802.3ah

• Port authentication, IEEE 802.1X

• Ethernet local management interface (E-LMI), ITU-T Q.933.

• Link layer discovery protocol (LLDP)

• Multiple registration protocol (MRP)

• Generic attribute registration protocol (GARP)

The PTP 810 system processes the following L2CPs:

• Spanning Tree Protocol (STP)

• Rapid Spanning Tree Protocol (RSTP)

• Multiple Spanning Tree Protocol (MSTP)

• Pause frames

• Link Aggregation Control Protocol (LACP)

Maximum frame size

The maximum frame size for bridged frames in the customer network is as follows:

• Standard Master I/O: 2048 octets.

• GigE Master I/O: 4000 octets (“S” software version) or 9728 octets (“J” software version).

Page 79: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Ethernet bridging in the customer network

phn-2779_001v000 (Jul 2012) 1-39

Internal Ethernet switch

The PTP 810 MMU contains an internal Ethernet switch. Switch ports consist of front panel copper Ethernet ports, a front panel SFP port for copper or fiber connections, and internal ports connecting the switch to one or two wireless modems.

The internal switch in the Standard Master I/O module is shown in Figure 28, and the internal switch in the GigE Master I/O module is shown in Figure 29.

The internal Ethernet switch in the Standard Master I/O module is limited to 100 Mbps per port. This means that the combined Ethernet traffic to and from the two front panel ports to a given modem (that is, the East Modem or West Modem) is limited to 100 Mbps. Likewise, Ethernet traffic that is relayed between the East and West modems is also routed via the Ethernet switch and is therefore limited to 100 Mbps.

The internal Ethernet switch in the GigE Master I/O module has a limit of 1000 Mbps per port which does not place any restrictions on the Ethernet traffic data rate in practice.

Figure 28 Internal Ethernet switch for the Standard Master I/O module

Page 80: Cambium network ptp 810 series 01 00 user guide

Ethernet bridging in the customer network Chapter 1: Product description

1-40 phn-2779_001v000 (Jul 2012)

Figure 29 Internal Ethernet switch for the GigE Master I/O module

The internal Ethernet switch provides standard forwarding of Ethernet frames, including flooding of multicast or broadcast frames, learning the location of end stations from the source address of ingress frames, and filtering of unicast frames with known destination address. The filter database (FDB) has capacity for up to 1024 learned MAC addresses.

On an East link failure, all E1/T1 circuits on the East, if any, will transfer to the West link, consuming the amount of Ethernet throughput equivalent to the number of E1/T1s transferred. Conversely, if the East link has no E1/T1 circuits configured and E1/T1 circuits are carried by the West link, on a East link failure the West link E1/T1 circuits will be lost and replaced by Ethernet capacity.

Spanning tree operation

The internal Ethernet switch in the PTP 810 MMU supports Rapid Spanning Tree Protocol (RSTP) and Multiple Spanning Tree Protocol (MSTP). These protocols detect loops in bridged Ethernet networks, and block ports as needed to provide connectivity equivalent to a simply-connected spanning tree. The MMU allows port priority to be configured for individual switch ports, so that the default spanning tree can be optimized for carrying likely traffic patterns.

RSTP

The RSTP implementation in the MMU complies with IEEE 802.1D-2004 Clauses 9 and 17 and interoperates with standard RSTP and STP instances in other network equipment.

If a wireless link fails in a network containing loops, RSTP will re-enable blocked ports to restore connectivity with the remaining units.

Page 81: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Ethernet bridging in the customer network

phn-2779_001v000 (Jul 2012) 1-41

The RSTP ‘Hello’ time is configurable between 1 and 10 seconds. RSTP typically restores an outage in 3 ‘Hello’ times. However, the actual restoration time depends on network configuration and cannot be guaranteed. An additional Fast Hello configuration (600 ms to 900 ms) is supported in the MMU for applications where the network consists of only MMUs. The Fast Hello operation reduces the time taken for the network to converge the spanning tree, but is not compatible with other network equipment.

MSTP

The MSTP implementation in the MMU complies with IEEE 802.1s and is backward compatible with RSTP and STP. MSTP configures a separate spanning tree for each VLAN group, referred to as a Multiple Spanning Tree Instance (MSTI), and blocks all but one of the possible alternate paths within each spanning tree.

MSTP allows the formation of MSTI regions. A MSTI region is a collection of switches that share the same MSTP configuration name and revision attributes. Bridges must share the same VLAN-to-MSTI mapping configuration as well as the same configuration name and revision attributes in order to share spanning trees for intra-region MSTIs.

The MSTP protocol uses a variable known as Maximum Hops as a time to live counter instead of the Maximum Age timer used by RSTP. The Maximum Age timers are still used when MSTP interacts with RSTP bridges.

If a wireless link fails in a network containing loops, MSTP will re-enable blocked ports to restore connectivity with the remaining units.

Pause frame operation

PTP 810 allows the customer traffic and management Ethernet ports to be individually configured to operate with Ethernet flow control using standard IEEE 802.3 Pause frames. In the GigE Master I/O module, the customer data ports can additionally be configured to generate Pause frames but not to respond to them, or to respond to Pause frames but not to generate them. Pause frames are transmitted at all ports configured for Pause frame operation when the buffer of the internal switch becomes nearly full.

Ethernet link aggregation

The GigE Master I/O module supports aggregation of Ethernet links at the front panel ports using the standard Link Aggregation Control Protocol (LACP) specified in IEEE 802.1ax.

Page 82: Cambium network ptp 810 series 01 00 user guide

Ethernet bridging in the customer network Chapter 1: Product description

1-42 phn-2779_001v000 (Jul 2012)

Transparent wireless link aggregation (GigE Master I/O module)

The GigE Master I/O module can be configured to provide transparent wireless link aggregation in 2+0 co-polar, 2+0 cross-polar and 2+0 XPIC link types. Transparent wireless link aggregation automatically distributes Ethernet frames between the two links (regardless of the content of Ethernet or IP header fields) to ensure that the wireless links are evenly loaded, with the result that the aggregated link has exactly the combined capacity of the individual wireless links.

VLAN bridging of Ethernet Traffic

The MMU provides Ethernet Virtual Local Area Network (VLAN) configuration. The MMU supports Port based VLAN and Static Tag based VLAN. Static Tag based VLAN supports Single Tag mode, Double Tag (S tag + C tag) mode and Double Tag (C tag + C tag) mode.

Users can enable only one type of VLAN at a time. It can be either Port based VLAN or Static Tag based VLAN.

• Port Based VLAN: In Port Based VLAN, users are able to configure which ports are connected to each other. Frame Forwarding is allowed only among the ports that are part of the same VLAN.

• Static Tag Based VLAN: The MMU supports up to 64 VLANs. Each VLAN is identified by its distinct VLAN ID (between VLAN ID 1 to 4094). Users can Add/Edit/Delete VLANs and ports that belong to each VLAN. Two modes are available:

o Single Tag Mode: Single Tag mode is as specified in IEEE802.1Q. Users configure which ports are part of a VLAN and the Ingress/Egress Policy of the ports. Frame Forwarding is allowed only among the ports that are part of the same VLAN and the forwarding is done based on the VLAN tag.

o Double Tag Mode: Double Tag (S tag + C tag) mode and Double Tag (C tag + C tag) mode is as specified in IEEE802.1ad. Users configure which port is part of a VLAN and whether the port is a Network port or User port. Frame Forwarding is allowed only among the ports that are part of the same VLAN and the forwarding is done based on the outer VLAN tag.

VLAN bridging single-tagged mode

The PTP 810 MMU supports standard IEEE 802.1Q-2004 VLAN bridging operation in the internal Ethernet switch for single-tagged or customer VLAN operation including:

• Creation and deletion of VLANs.

• Addition and removal of ports from the member list of VLANs.

• Filtering of ingress and egress frames at each port based on matching the VID of the frame with the VLAN member lists.

• Application of the ingress policy for each of the front panel ports:

o Admit All Frames: Admits tagged and untagged frames.

Page 83: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Ethernet bridging in the customer network

phn-2779_001v000 (Jul 2012) 1-43

o Admit Tag Only: Admits only tagged frames.

• Insertion of a VLAN tag in untagged ingress frames, using the default VID for each port (assuming that the port is configured to admit untagged frames).

• Setting of a default priority for each port in untagged ingress frames (assuming that the port is configured to admit untagged frames).

• Application of the egress policy for each of the front panel ports:

o Remove: Removes the VLAN tag from egress frames before transmission.

o Don’t Remove: Retains the VLAN tag in transmitted frames.

The internal modem ports have fixed policies equivalent to Admit All Frames and Don’t Remove. This means that all frames passing across the wireless link (between two MMUs) are tagged. The internal modem ports must be present in the appropriate VLAN member lists to allow VLAN frames to be forwarded between MMUs.

VLAN bridging double-tagged modes

In addition to the standard customer VLAN capabilities, the internal Ethernet switch can also be configured as a VLAN bridge for double-tagged frames with the following VLAN bridging modes:

• Double tagged (S-Tag plus C-Tag)

• Double tagged (C-Tag plus C-Tag)

The tag protocol ID (TPID) is 0x8100 for C-Tags and 0x88a8 for S-Tags. Double tagged frames with two C-Tags are described as ‘Q-in-Q’.

In the double-tagged VLAN modes, individual front panel ports can be configured in the following Port Double Tag Modes:

• Network Port

• User Port

The User Port setting will normally be used where an MMU front panel port forms the User-Network Interface (UNI) between a service provider and a customer. The Network Port setting will normally be used within a provider-bridged network.

When the VLAN Management is “Double Tag” the egress policy is not configured via a dedicated parameter but it is automatically determined on the base of the Port Double Tag Mode configuration. If the port has been configured as "Network" its egress policy is automatically configured to "Don't Remove". If the port has been configured as "User" its egress policy is automatically configured as "Remove".

Table 3 describes how VLAN tags are inserted in ingress frames in double-tagged VLAN operation.

Page 84: Cambium network ptp 810 series 01 00 user guide

Ethernet bridging in the customer network Chapter 1: Product description

1-44 phn-2779_001v000 (Jul 2012)

Table 3 Insertion of tags in ingress frames in double tagged mode

VLAN Management Mode

Frame Type Port Double Tag Mode

Ingress Action

Double Tag (S-Tag and C-Tag)

Untagged - Single S-Tag added

Single Tagged - Outer S-Tag added

Double Tagged (S-tag and C-Tag)

Network Unmodified

User Outer S-Tag added

Double Tagged (C-Tag and C-Tag)

- An additional S-Tag is ALWAYS added because the frame is not recognized as an S-Tag + C-Tag frame, regardless of the ingress port double tag mode type.

Double Tag (Ctag + Ctag)

Untagged - Single C-Tag added

Single Tagged - Outer C-Tag added

Double Tagged (S-tag and C-Tag)

- An additional C-Tag is ALWAYS added because the frame is not recognized as a C-Tag + C-Tag frame, regardless the ingress port double tag mode type.

Double Tagged (C-Tag and C-Tag)

Network Unmodified

User Outer C-Tag added

The most likely network deployment of the doubled-tagged mode is based on Ethernet frames with a single C-Tag forwarded by the MMU between the provider network and the user’s network at the UNI, and double-tagged frames with S-Tag and C-Tag forwarded by the MMU internal to the provider bridged network.

Internal modem ports always operate in the Network Port mode, with fixed policies equivalent to Admit All Frames and Don’t Remove. All frames will be tagged at the internal modem ports, and additional tags are never added.

Port-based forwarding

Port-based forwarding provides a means to configure forwarding between individual front panel Ethernet ports and individual wireless modems and offers a means to create virtual networks without using VLAN bridging.

For example, in a 2+0 co-polar, 2+0 cross-polar or 2+0 XPIC link type, port-based forwarding could be used to create two separate networks, one using the East wireless link and one using the West wireless link.

Page 85: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Ethernet bridging in the customer network

phn-2779_001v000 (Jul 2012) 1-45

Port-based forwarding is not compatible with wireless link aggregation.

Quality of service for bridged Ethernet traffic

The PTP 810 system provides four queues for Ethernet frames waiting for transmission over the wireless interface.

Ethernet frames may be classified into these queues based on either (a) the associated ingress port, or (b) the Ethernet priority or IP Differentiated Services Code Point (DSCP) within the frame.

Port priority cannot be used at the same time as Ethernet and DSCP priority.

QoS in the Standard Master I/O module

The Standard Master I/O module can be configured to use strict priority scheduling or weighted fair queueing scheduling. Port priorties, and Ethernet or DSCP priorties are mapped directly to one of the four transmission queues.

QoS in the GigE Master I/O module

The GigE Master I/O module uses weighted fair queueing scheduling, with an option to select strict priority for the highest priority transmission queue. Port priorties, and Ethernet or DSCP priorties are mapped first to one of eight switch priorities, and switch priorities are each mapped to one of the four transmission queues.

Wireless link down alert

The PTP 810 system can be configured to alert a ‘loss of link’ to the connected network equipment. It does this by means of a brief disconnection of selected Ethernet ports.

The alert is triggered by any condition which prevents the link from forwarding traffic in one or both link directions. Examples include a deep wireless fade, or equipment failure such as an ODU failure.

The wireless link down alert can be deployed in networks which use external network equipment to provide alternative traffic routes in the event of failure. Spanning Tree Protocol (STP) and industry standard ring protocols are commonly deployed in such complex networks and will react to the wireless link down alert.

Page 86: Cambium network ptp 810 series 01 00 user guide

Ethernet bridging in the customer network Chapter 1: Product description

1-46 phn-2779_001v000 (Jul 2012)

The Wireless link down alert cannot be used for customer data when RSTP is enabled for the customer data network in the MMU.

Further reading on Ethernet bridging

For more information on Ethernet bridging, refer to the following:

• Data network planning on page 2-16 describes factors to be considered when planning PTP 810 data networks.

• Data network specifications on page 4-73 contains specifications of the PTP 810 Ethernet interfaces.

• Task 2: Configuring IP and Ethernet interfaces on page 6-14 describes how to configure the IP and Ethernet attributes of the PTP 810.

Page 87: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Ethernet bridging in the management network

phn-2779_001v000 (Jul 2012) 1-47

Ethernet bridging in the management network

This section describes how the PTP 810 bridges Ethernet data in the management network.

Embedded management agent

The PTP 810 MMU contains an embedded network management agent used to configure and monitor the communications capabilities of the MMU. The network management agent connects to management systems and workstations using two different interfaces:

• A point-to-point RS-232 serial data link.

• A network management IP interface over a standard Ethernet link layer.

The serial data link is available at the Serial/Alarm connector on the MMU Control Module.

Ethernet connections to the management agent are at the NMS 1 and NMS 2 Ethernet ports on the MMU Control Module. The management agent can additionally be reached using Ethernet traffic over the wireless link, from the front panel NMS ports at the remote end of the wireless link.

The default IP address of the management agent is 192.168.0.1. The IP address can be configured using the serial interface even if the existing IP address is unknown.

Serial interface

The network management serial interface has the following characteristics:

• Data rate: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 kbit/s

• Data bits: 8

• Parity: None

• Stop bits: 1

• Flow control: None

Ethernet interface

The PTP 810 MMU contains an internal Ethernet switch used to connect together the management agent with the NMS front panel ports, and with network management channels multiplexed with customer data over one or two wireless links. The overall arrangement of the management Ethernet switch is shown in Figure 30.

Page 88: Cambium network ptp 810 series 01 00 user guide

Ethernet bridging in the management network Chapter 1: Product description

1-48 phn-2779_001v000 (Jul 2012)

Figure 30 Internal Ethernet switch for the management network

Ethernet Switch

East Modem

NMS Port 1100BASE-TX

West Modem

NMS Port 2100BASE-TX

Management Agent

Serial Port

The internal Ethernet switch provides standard forwarding of Ethernet frames, including flooding of multicast or broadcast frames, learning the location of end stations from the source address of ingress frames, and filtering of unicast frames with known destination address. The filter database (FDB) has capacity for up to 1024 learned MAC addresses.

Network management

The network management mode bridges Ethernet frames between front panel Ethernet ports and Management Agents at both ends of a link. This connectivity allows communication from the MMU management ports to Ethernet end stations reached through the remote MMU, supporting construction of an extended management network that is isolated from the customer network.

The MMU segregates customer and management traffic into separate channels both within the MMU and over the air.

Page 89: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Ethernet bridging in the management network

phn-2779_001v000 (Jul 2012) 1-49

Spanning tree operation

The internal Ethernet switch in the PTP 810 management network supports Rapid Spanning Tree Protocol (RSTP). This protocol detects loops in bridged Ethernet networks, and blocks ports as needed to provide connectivity equivalent to a simply-connected spanning tree. The MMU allows port priority to be configured for individual switch ports, so that the default spanning tree can be optimized for carrying likely traffic patterns.

If a wireless link fails in a network containing loops, RSTP will re-enable blocked ports to restore connectivity with the remaining units.

Network management quality of service

Network management traffic is forwarded over the wireless link using a dedicated channel with capacity of approximately 500 kbit/s. The management channel represents a single traffic class, and the same quality of service is afforded to all management frames.

Page 90: Cambium network ptp 810 series 01 00 user guide

System management Chapter 1: Product description

1-50 phn-2779_001v000 (Jul 2012)

System management

This section introduces the PTP 810 management system, including the web interface, installation, configuration, alerts and upgrades.

Protocol interfaces

The management agent supports the following protocol interfaces for the serial connection:

• Text-based command line interface (CLI)

The management agent supports the following protocol interfaces over IP and Ethernet:

• Text-based CLI over Telnet

• Text-based CLI over Secure Shell (SSH)

• Web-based interface using Hyper text transfer protocol (HTTP)

• Simple network management protocol (SNMP), v1, v2c, v3

• Simple mail transfer protocol (SMTP)

• Simple network time protocol (SNTP)

• System logging (syslog)

Web server

The PTP 810 management agent contains a web server. The web server supports the HTTP interface.

Web-based management offers a convenient way to manage the PTP 810 equipment from a locally connected computer or from a network management workstation connected through a management network, without requiring any special management software.

Command line interface

PTP 810 provides a convenient and intuitive text-based command line interface (CLI). The page structure, access rights and user accounts are shared between the web-based interface and the CLI. In general, the CLI provides the same capabilities as the web-based interface and is a viable alternative for applications where use of a web-browser would not be appropriate.

The CLI may be encrypted using Secure Shell (SSH) using the MMU private key and device certificate. SSH supports DES and AES128 encryption.

Page 91: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide System management

phn-2779_001v000 (Jul 2012) 1-51

Identity-based user accounts

User accounts can be added and deleted for different access levels, including field configurable passwords. Refer to Managing user accounts and security on page 7-27.

PTP 810 allows up to seven user accounts, with three accounts configured by default. Details of the default accounts are shown in Table 4.

Table 4 Default user accounts

User name Access level Default password

administrator Administrator d1scovery

operator Operator col1ma

monitor Monitor monitor

The Administrator user may delete the Operator and Monitor accounts, and may create additional Operator and Monitor accounts up to a total of six accounts. The username of Administrator account cannot be changed.

Access rights for user accounts

The access rights for users of the web-based interface and text-based CLI are as shown in Table 5.

Table 5 Web-based and CLI access rights

Page Monitor Operator Administrator

Home Read only Read/write Read/write

General Device Information Read only Read/write Read/write

Configuration Summary Read only Read/write Read/write

Active Alarm Status Read only Read/write Read/write

Alarm History Read only Read/write Read/write

All Graphs Read only Read/write Read/write

Data Switch and NMS Switch Statistics Read only Read/write Read/write

Reboot - Read/write Read/write

All Radio Link and Data Link Configuration pages

- Read/write Read/write

Alarm Threshold page - Read/write Read/write

BERT page - Read/write Read/write

All Network Configuration - - Read/write

Page 92: Cambium network ptp 810 series 01 00 user guide

System management Chapter 1: Product description

1-52 phn-2779_001v000 (Jul 2012)

Page Monitor Operator Administrator

Serial and Security configuration - - Read/write

All Device Information pages - - Read/write

All Maintenance and Restore Defaults pages - - Read/write

Alarm Configuration page - - Read/write

STP Screens - - Read/write

Loopback page - - Read/write

Link configuration wizard

The web-based interface includes a link configuration wizard. This feature simplifies the process of entering initial configuration details. The process handles the important configuration settings that must be set to comply with individual license conditions.

Alarms

The management agent can be configured to generate alerts as SNMP notifications or electronic mail messages when an alarm condition occurs. Alarm conditions are also reported as syslog messages. Active alarms are listed on the Active Alarms web page. An alarm history is provided on the Alarm History web page.

A comprehensive list of the possible alarm conditions is provided in Alarms on page V.

Alarm configuration

The PTP 810 MMU allows each alarm condition to be masked. A masked alarm will not be generated or notified in the web-based interface, and will not generate SNMP notifications. Alarm configuration is available on the Alarm Configuration web page.

External alarms

PTP 810 provides four external alarm inputs and four external alarm outputs. Alarm conditions signalled at the external alarm inputs can be repeated as SNMP notifications. External alarm outputs can be individually configured to repeat one or more of the internal or external alarms using the Alarm Configuration web page

Page 93: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide System management

phn-2779_001v000 (Jul 2012) 1-53

Controller status indicator

The Status indicator on the Control Module is the primary front panel indicator of alarms. The Status indicator can operate in two ways:

• Solid on

• Flashing to indicate alarm code.

Alarms on page V provides a complete list of alarms and indicates in each case whether the alarm is solid or will flash a code.

When an alarm with a code is active:

(a) The Controller Status indicator turns orange for five seconds.

(b) The Controller Status indicator turns off for five seconds.

(c) The Controller Status indicator flashes orange the number of times specified by the first digit of the alarm code.

(d) The Controller Status indicator turns off for three seconds.

(e) The Controller Status indicator flashes orange the number of times specified by the second digit of the alarm code.

Steps (b) to (e) are repeated for each active alarm. The entire process is repeated as long as the alarms are still posted.

SNMP

The MMU management agent supports fault, configuration and performance management by means of an SNMP interface. The management agent is compatible with SNMP v1, SNMP v2c and SNMPv3, using the following MIBs:

• PTP 810 enterprise MIB

• EtherLike-MIB (RFC3635)

• IF-MIB (RFC2863)

• IANAifType-MIB

• PerfHist-TC-MIB

• DS1-MIB (RFC3895)

• SONET-MIB (RFC3592)

The PTP 810 enterprise MIB is available for download in the application software package from the support web page (see Contacting Cambium Networks on page 2).

Further details of the standard SNMP MIB objects supported by PTP 810 are provided in Standard SNMP MIBs on page 4-77.

SNMP must be enabled for use by means of the SNMP Mode attribute in the web-based interface.

Page 94: Cambium network ptp 810 series 01 00 user guide

System management Chapter 1: Product description

1-54 phn-2779_001v000 (Jul 2012)

SNMPv3 security

PTP 810 supports SNMPv3 security for a single user with the following configuration:

• Username: admin

• Privacy protocol: DES

• Authentication protocol: MD5

• Security model: AuthPriv

PTP 810 allows the privacy and authentication passphrases to be configured in the SNMP Configuration web page.

Simple Network Time Protocol (SNTP)

An internal clock supplies accurate date and time information to the system. It can be set to run with or without a connection to a network time server (SNTP). It can be configured to display local time by setting the time zone in the Set Date and Time web page. If an SNTP server connection is available, the clock attempts to synchronize with the server time at regular intervals.

System logging (syslog)

PTP 810 supports the standard syslog protocol to log important configuration changes, status changes, events and alarms to a standard syslog server. The protocol complies with RFC 3164. The MMU sets a configurable syslog facility field (Local0 to Local7) in syslog messages.

All alarm notifications sent by SNMP are repeated as syslog messages.

Flexible capacity upgrades

PTP 810 MMUs are shipped with a data throughput capacity of 10 Mbps and without XPIC capability. To increase capacity or to allow XPIC capability, license keys or license key upgrades must be purchased from Cambium.

Capacity license keys are sold per PTP 810 MMU unit and are available in the following capacity increments (units of Mbps): 20, 30, 40, 50, 100, 150, 200, 300, 400, and 600. Each of these capacity values is mapped to the over-the-air maximum throughput capacity of the various modulation modes (channel size and modulation) in order to determine which modulation modes will be enabled for a given capacity license key.

XPIC capability license keys are sold per PTP 810 MMU unit.

Page 95: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide System management

phn-2779_001v000 (Jul 2012) 1-55

The capacity license key directly controls the allowed modulation modes and channel bandwidths and therefore has an impact on link performance.

For ordering details including Cambium part numbers, refer to Ordering capacity upgrades and XPIC capability on page 2-40.

Application software storage and upgrade

The MMU uses separate software images for the following components and modules:

• Controller kernel

• Controller application

• Controller FPGA

• Master I/O FPGA

• Modem East firmware

• Modem East FPGA

• Modem West firmware

• Modem West FPGA

• Expansion I/O FPGA

• ODU

• ODU boot loader

The MMU uses dual-bank storage for each of the software components. Software images are upgraded by installing a new image in the inactive bank and then toggling the active and inactive banks. In two cases, the alternative bank contains valid alternative software:

• The Modem FPGA code. The alternative bank contains the SW needed for XPIC. For example:

Modem East FPGA: 4700_PIxx.xx.xx versus 4700_UMyy.yy.yy

• The GigE Master IO code. The alternative bank contains the "S" version. For example:

CCM-4130: 4130_JGxx.xx.xx versus 4130_SGxx.xx.xx

The MMU supports two software versions: “J” and “S” (Table 6).

Table 6 MMU software versions

Software version Maximum frame size SNCP-like protection supported?

J 9728 bytes No

S 4000 bytes Yes (used with 1+0 Ethernet rings)

Software is installed in the MMU using File Transfer Protocol (FTP).

Page 96: Cambium network ptp 810 series 01 00 user guide

System management Chapter 1: Product description

1-56 phn-2779_001v000 (Jul 2012)

Software may be upgraded as a complete package, in which case all the components are loaded into the inactive banks and all components are toggled to bring the new software into use.

Restore system defaults

Web interface

A PTP 810 MMU can be returned to a default configuration using the Restore System Defaults web page. The IP address and passwords are reset.

Power on reset to system defaults

The MMU may be reset to factory defaults during power up. A power-on reset affects the IP address and the usernames and passwords. The power-on reset provides a means to recover from serious configuration errors including lost or forgotten passwords and unknown IP addresses. For more information, refer to Power on reset to system defaults on page 7-54.

Further reading on system management

For more information on system management, refer to the following:

• Chapter 6: Configuration and alignment describes all configuration and alignment tasks that are performed when a PTP 810 link is deployed.

• Chapter 7: Operation provides instructions for operators of the PTP 810 web user interface.

Page 97: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide TDM bridging

phn-2779_001v000 (Jul 2012) 1-57

TDM bridging

This section describes PTP 810 capabilities for E1/T1 transmission over wireless links, and for switching of E1/T1 circuits within the MMU.

E1/T1 capacity

PTP 810 allows a user to configure a variable number of E1/T1 circuits over each wireless link, subject to:

• The capacity of the wireless link for combined Ethernet and E1/T1 data

• The number of E1/T1 circuits that can be handled by the Master I/O module.

• The number of front panel E1/T1 ports.

Capacity of the wireless link

The capacity of a PTP 810 wireless link for combined Ethernet and E1/T1 data depends on the channel bandwidth and modulation mode used. These characteristics of the wireless link set an upper limit on the number of E1/T1 circuits that can be configured. The tables in Maximum E1/T1 circuit capacity on page 4-27, or PTP LINKPlanner can be used to determine the number of E1/T1 circuits that can be carried over any given wireless link.

In MMU configurations for dual 1+0 links, the maximum number of E1/T1 circuits for the MMU is the sum of the number of circuits accommodated by the individual links. MMU configurations for the 2+0 link types have double the link capacity of a single link, and therefore double the maximum number of E1/T1 circuits provided by an equivalent 1+0 link.

Master I/O module

The maximum number of E1/T1 circuits supported in a single link also depends on the Master I/O module with the following limits:

• Standard Master I/O Module: 126 circuits per link.

• GigE Master I/O Module: 63 circuits per link.

In many applications, the number of circuits that can be accommodated within the link capacity will be lower than these limits imposed by the Master I/O. Only links with wide channel bandwidth and high modulation mode will have sufficient link capacity to support more than 63 circuits.

MMU configurations for 2+0 link types accommodate up to 63 or 126 E1/T1 circuits for each link.

Page 98: Cambium network ptp 810 series 01 00 user guide

TDM bridging Chapter 1: Product description

1-58 phn-2779_001v000 (Jul 2012)

Front panel E1/T1 ports

PTP 810 has a maximum capacity for E1/T1 ports at the MMU front panel (Table 7).

Table 7 E1/T1 port capacity

Master I/O module Expansion module Front panel E1/T1 ports

Standard - 16

Standard 16 × E1/T1 32

GigE - 2

GigE 16 × E1/T1 18

Remaining capacity for Ethernet data

The link capacity for Ethernet data is the remaining capacity after resources have been reserved for the configured E1/T1 circuits. The PTP LINKPlanner calculates the remaining capacity for Ethernet data for any supported combination of E1/T1 circuits, channel bandwidth and modulation mode.

E1/T1 clocking

PTP 810 preserves the service clock in bridged E1/T1 circuits. In other words, the E1/T1 transmit clock at the local MMU is set to the average frequency of the E1/T1 clock in the data stream received at the remote MMU. Each circuit is clocked separately, and there is no requirement for multiple E1/T1 circuits to share a common clock. The MMU does not provide facilities for internal or external clock sources.

PTP 810 provides E1/T1 with very low added wander, consistent with the requirements of ITU-T G.823 and G.824.

Page 99: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide TDM bridging

phn-2779_001v000 (Jul 2012) 1-59

Identification and mapping of E1/T1 circuits and ports

The overall arrangement of E1/T1 switching in a TDM switch is shown in Figure 31.

Any Channel can be mapped to any other channel within the TDM switch. This includes MA to MA or EX. Loopback is even possible.

Figure 31 Switching of E1/T1 circuits in 1+0 and 1+1 links

E1/T1 switching in 1+0 and 1+1 link types

E1/T1 TDM switching in the MMU allows any front panel E1/T1 port to be mapped to any E1/T1 circuit over the wireless link. This means that a PTP 810 link can map any front panel port at the near end of a link to any front panel port at the remote end of the link.

Page 100: Cambium network ptp 810 series 01 00 user guide

TDM bridging Chapter 1: Product description

1-60 phn-2779_001v000 (Jul 2012)

In 1+0 links the East modem is always used. All mappings must be done from the Master IO and Expansion modules to the East modem.

In 1+1 links the West modem is automatically used as the standby modem. No mapping should be performed to the West modem.

When performing the mapping, the MMU silently ignores invalid mapping configurations.

Dual 1+0 links

E1/T1 TDM switching in the MMU supports a relay operation where E1/T1 circuits can be connected between the East and West modems within the MMU. E1/T1 circuits carried by the East or West modem can alternatively be terminated at a front panel port similar to the arrangement in the 1+0 link type.

For example, E1/T1 switching for the dual 1+0 configuration (Figure 31) consists of:

• Termination: "E3, MA1", "W3, MA3" and so forth.

• Relay/Passthrough: "E1, W1", "E2, W2" and so forth.

• Ring: (using SNCP-like): see SNCP-like protection on page 1-60.

E1/T1 mapping for circuits relayed within the MMU is recorded as shown in the following example:

E1, W1

E2, W2

E1/T1 mapping for circuits switched to the MMU front panel is recorded as follows:

E3, MA1

E4, MA2

W3, MA3

W4, MA4

SNCP-like protection

The Standard Master I/O module and the GigE module with “S” software support circuit-based E1/T1 protection, whereby a circuit from the East modem and a circuit from the West modem can be mapped to the same front panel port. This protection is similar in concept to Sub-Network Connection Protection (SNCP) commonly used in SDH networks.

Page 101: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide TDM bridging

phn-2779_001v000 (Jul 2012) 1-61

The Master I/O module duplicates E1/T1 data from a single front panel port and transmits identical data on two circuits carried by different modems. The Master I/O module monitors E1/T1 data received from two circuits carried by two different modems, and selects data from one of the circuits, based on the AIS state of the two circuits. Protection switching normally occurs within 50 ms of detection of a fault.

E1/T1 mapping for circuits with SNCP-like protection is recorded as shown in the following example:

E1:W1, MA1

E2:W6, EX3

In the protection couplet, the first circuit is the primary or working circuit, and the second is the secondary or protection circuit.

SNCP-like protection is used with dual 1+0 links, and can be used to create redundant routes in networks with a ring or mesh topology.

E1/T1 switching in 2+0 co-polar, 2+0 cross-polar and 2+0 XPIC link types

In the 2+0 co-polar, cross-polar and XPIC link types, the MMU allows E1/T1 front panel ports to be mapped to either of the wireless links.

Protection switching in 2+0 co-polar, cross-polar and XPIC

E1/T1 circuits carried by the East modem have preference if one link fails in a 2+0 co-polar, 2+0 cross polar or 2+0 XPIC configuration. If the link supported by the East modem fails, the E1/T1 circuits mapped in the East modem are transferred to the West modem, and any circuits mapped to the West modem (there may be none) are dropped.

This applies even in cases where no E1/T1 circuits are configured for a given East/West link. If the West link has no E1/T1 circuits configured, on an East link failure all E1/T1 circuits will transfer to the West link, consuming the amount of Ethernet throughput equivalent to the number of E1/T1s transferred. Conversely, if the East link has no E1/T1 circuits configured and E1/T1 circuits are carried by the West link, on an East link failure the West link E1/T1 circuits will be lost and replaced by Ethernet capacity.

Page 102: Cambium network ptp 810 series 01 00 user guide

TDM bridging Chapter 1: Product description

1-62 phn-2779_001v000 (Jul 2012)

Loopback

The MMU provides system loopback points as a means for testing TDM interface points, bridging connectivity and link performance. Loopback points are available at the local interface unit, local modem and remote interface unit. Loopback points and the duration of the loopback test are selected through the MMU GUI.

PTP 810 supports three types of loopback test for troubleshooting purposes (Figure 32).

For more information, see Performing a loopback test on page 8-15.

Figure 32 Supported loopback tests

Further reading on TDM bridging

For more information on TDM bridging, refer to the following:

• Installing an E1/T1 interface on page 5-83 describes how to install network connections for E1/T1 interfaces.

• Trouble bridging E1/T1 traffic on page 8-15 describes how to investigate problems experienced with E1/T1 channels in a newly installed (or operational) link.

Page 103: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide

phn-2779_001v000 (Jul 2012) 2-1

Chapter 2: Planning considerations

This chapter provides the product information needed to plan a PTP 810 link, and highlights decisions that need to be made as part of the planning process. The following topics are described in this chapter:

• Link planning on page 2-2 describes factors to be taken into account when planning PTP 810 links, such as site selection and cable length, and it introduces the PTP LINKPlanner.

• Grounding and lightning protection on page 2-7 describes the grounding and lightning protection requirements of PTP 810 installations.

• Data network planning on page 2-16 describes factors to be considered when planning PTP 810 data networks.

• TDM network planning on page 2-19 describes factors to be considered when planning PTP 810 TDM networks.

• Planning 1+0 links on page 2-22 describes how to plan 1+0 links.

• Planning 1+1 links on page 2-25 describes how to plan 1+1 Hot Standby and 1+1 Hot Standby Spatial Diversity links.

• Planning 2+0 links on page 2-31 describes how to plan 2+0 Co-polar, Cross-polar and XPIC links.

• Planning Dual 1+0 links on page 2-37 describes how to plan Dual 1+0 links.

• Ordering components on page 2-39 describes how to select components for a planned PTP 810 link (as an alternative to PTP LINKPlanner). It specifies Cambium part numbers for PTP 810 components.

Page 104: Cambium network ptp 810 series 01 00 user guide

Link planning Chapter 2: Planning considerations

2-2 phn-2779_001v000 (Jul 2012)

Link planning

This section describes factors to be taken into account when planning PTP 810 links, such as site selection and cable length, and it introduces the PTP LINKPlanner.

Process

The majority of the 6 to 38 GHz spectrum is licensed on a link by link basis. Adapt the planning process to suit the licensing regime that is in force in the country of operation.

To plan the link, follow this high-level process:

1 Identify suitable sites at the ends of the link.

2 Determine the data capacity, E1/T1 capacity and wireless link availability required for the link.

3 Select an RF band, taking into account the range of link, the capacity required, the wireless link availability required, the licensing policy for bands in the region or country, and ease (or otherwise) of obtaining individual licenses in that band.

4 Use the PTP LINKPlanner to check that a satisfactory, unobstructed, line-of-sight path is possible between the ends.

5 For links over water, use the reflection analysis feature of LINKPlanner to determine whether spatial diversity is needed to counter multipath reflections.

6 Select the link type for the link:

a. Regulators may mandate, or at least recommend, spatial diversity for certain lengths of link, or for links in certain regions.

b. Spatial diversity may be needed to achieve the required wireless link availability in LINKPlanner. Only 1+1 HSB SD is supported (no 1+0 SD).

c. Select antenna sizes to achieve capacity and availability requirements.

d. Consider using 1+1 HSB or 2+0 links in critical applications where the hardware availability of a single 1+0 link would be insufficient.

e. Consider using 2+0 links where the capacity of a wideband 1+0 link is insufficient. Consider 2+0 XPIC links where regulators are reluctant to grant licenses for two channels on different frequencies.

7 Apply for an individual license, or individual licenses as required.

8 Use the PTP LINKPlanner with the license details to identify a Bill of Materials for the link.

9 Order equipment from Cambium.

Page 105: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Link planning

phn-2779_001v000 (Jul 2012) 2-3

Cambium offers a license coordination service for links in the USA. The service includes link study, PCN, FCC application filling, Schedule-K completion and one year license protection warranty. The FCC Microwave license coordination service may be ordered as Cambium part number WB3659.

Site selection

To provide a clear line-of-sight path for the link, mount the antennas where they are elevated above their immediate surroundings and above obstructions. Use LINKPLanner to determine suitable antenna heights to clear the terrain. Conduct a site survey to ensure that there are no other obstacles.

Wind loading

Select a site where the wind load will not be too high.

Maximum permitted wind load depends upon antenna diameter: the greater the diameter, the lower the maximum permitted wind load. For example, a 1.8 m (6 ft) antenna used in the 6 GHz band has maximum permitted wind loads of:

• Operational wind velocity: 110 km/h (68 mph)

• Peak survival wind velocity: 200 km/h (124 mph)

Maximum IF cable length

Select a site where the IF cable will not be too long. The maximum permitted IF cable length is 190 meters (620 ft) with CNT-400 or equivalent cable.

For deployments that require a cable length greater than 190 meters (620 ft), contact customer support (see Contacting Cambium Networks on page 2).

Page 106: Cambium network ptp 810 series 01 00 user guide

Link planning Chapter 2: Planning considerations

2-4 phn-2779_001v000 (Jul 2012)

PTP LINKPlanner

Use the Cambium PTP LINKPlanner to design PTP 810 links. This is a link planning and optimization tool designed for use with all PTP products. PTP LINKPlanner is free and available from the support web page (see Contacting Cambium Networks on page 2). The advantages of PTP LINKPlanner are as follows:

• It is supported on Windows and Macintosh Platforms.

• It is very easy to use without specialist radio planning knowledge.

• It is powerful, implementing applicable ITU recommendations for predicting the performance of a radio link.

• It expresses the performance in terms of data link capacity.

• It is integrated with Google Earth™ to facilitate site entry and path visualization.

• It provides bill of materials data for ease of purchasing.

• It can provide path data by an automated email service.

• It can model the PTP 250, PTP 400, PTP 500, PTP 600, PTP 800 and PTP 810 products.

• It can plan multiple links in the same session.

• It can generate an export file for Cambium's FCC Coordination service.

The PTP LINKPlanner provides path profile information for individual links as shown in Figure 33.

Page 107: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Link planning

phn-2779_001v000 (Jul 2012) 2-5

Figure 33 LINKPlanner profile view

The PTP LINKPlanner also provides configuration and performance details as shown in Figure 34, and Bill of Materials data as shown in Figure 35.

This is necessarily a brief introduction to the PTP LINKPlanner. Please download and evaluate this free software in further detail.

Page 108: Cambium network ptp 810 series 01 00 user guide

Link planning Chapter 2: Planning considerations

2-6 phn-2779_001v000 (Jul 2012)

Figure 34 LINKPlanner configuration and performance details

Figure 35 LINKPlanner Bill of Materials view

Page 109: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Grounding and lightning protection

phn-2779_001v000 (Jul 2012) 2-7

Grounding and lightning protection

Ensure that the link meets the grounding and lightning protection requirements described in this section.

Electro-magnetic discharge (lightning) damage is not covered under warranty. The recommendations in this guide, when followed correctly, give the user the best protection from the harmful effects of EMD. However 100% protection is neither implied nor possible.

The need for power surge protection

Ensure that the planned PTP 810 installation protects structures, equipment and people against power surges (typically caused by lightning) by conducting the surge current to ground via a separate preferential solid path. The actual degree of protection required depends on local conditions and applicable local regulations. Cambium recommends that PTP 810 installation is contracted to a professional installer.

Standards

To gain a full understanding of lightning protection methods and requirements, refer to the international standards IEC 61024-1 and IEC 61312-1, the U.S. National Electric Code ANSI/NFPA No. 70-1984, or section 54 of the Canadian Electric Code.

International and national standards take precedence over the requirements in this guide.

Page 110: Cambium network ptp 810 series 01 00 user guide

Grounding and lightning protection Chapter 2: Planning considerations

2-8 phn-2779_001v000 (Jul 2012)

Lightning Protection Zones

Use the ‘rolling sphere method’ (Figure 36) to determine where it is safe to mount equipment. An imaginary sphere, typically 50 meters in radius, is rolled over the structure. Where the sphere rests against the ground and a strike termination device (such as a finial or ground bar), consider the space under the sphere to be in the zone of protection (Zone B). Where the sphere rests on two finials, consider the space under the sphere to be in the zone of protection.

Figure 36 Rolling sphere method to determine the lightning protection zones

Assess locations on masts, towers and buildings to determine if the location is in Zone A or Zone B:

• Zone A: In this zone a direct lightning strike is possible. Do not mount equipment in this zone.

• Zone B: In this zone, direct EMD (lightning) effects are still possible, but mounting in this zone significantly reduces the possibility of a direct strike. Mount equipment in this zone.

Never mount equipment in Zone A. Mounting in Zone A may put equipment, structures and life at risk.

Page 111: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Grounding and lightning protection

phn-2779_001v000 (Jul 2012) 2-9

General protection requirements

Ensure that the PTP 810 installation meets the general protection requirements described in this section.

Basic requirements

Install the outdoor equipment, that is antenna and ODU, in ‘Zone B’ (see Lightning Protection Zones on page 2-8).

Ground the indoor devices, that is the MMU, at their chassis bonding points.

Grounding cable requirements

Use grounding cables that meet the following requirements:

• Grounding cables are no less than 16mm2 or #6AWG in size, with solid or stranded, tinned and/or jacketed copper conductors.

• Grounding conductor runs are as short, straight, and smooth as possible, with the fewest possible number of bends and curves.

• Grounding cables are not installed with drip loops.

• All bends have a minimum radius of 203 mm (8 in) and a minimum angle of 90°. A diagonal run is preferable to a bend, even though it does not follow the contour or run parallel to the supporting structure.

• All bends, curves and connections are routed towards the grounding electrode system, ground rod, or ground bar.

• Grounding conductors are securely fastened.

• Braided grounding conductors are not used.

• Approved bonding techniques are employed when connecting dissimilar metals.

LPU and IF cable requirements

Use LPUs and IF cables that meet the following requirements:

• A lightning protection unit (LPU) (from the Cambium LPU kit, part number WB3657) is installed within 600 mm (24 in) of the point at which the IF cable enters the building or equipment room.

• The IF cable is bonded to the supporting structure in order to prevent lightning creating a potential between the structure and cable, which could cause arcing, resulting in damage to equipment.

• The IF cable is grounded at the building entry point.

Page 112: Cambium network ptp 810 series 01 00 user guide

Grounding and lightning protection Chapter 2: Planning considerations

2-10 phn-2779_001v000 (Jul 2012)

Specific requirements for the ODU

Ensure that all ODU installations meet the following requirements:

• The ODU and top LPU are as close together as possible.

• The IF cable length between the ODU and top LPU is less than 800 mm. The cable supplied in the accessory kit meets this requirement.

• The top LPU is mounted lower than the ODU.

• The ODU and top LPU are bonded together with the 800 mm long 16mm2, #6AWG cable supplied in the accessory kit.

• The LPU is bonded to the tower (or main grounding system) using the 600mm long 16mm2, #6AWG cable supplied in the accessory kit.

Protection requirements for a mast or tower installation

For equipment (ODU or antenna) mounted on a metal tower or mast, ensure that the installation meets the following requirements:

• The equipment is lower than the top of the tower or its lightning terminal and finial.

• The metal tower or mast is correctly grounded.

• A grounding kit is installed at the first point of contact between the IF cable and the tower, near the top.

• A grounding kit is installed at the bottom of the tower, near the vertical to horizontal transition point. This grounding kit is bonded to the tower or tower ground bus bar (TGB) if installed.

• If the tower is greater than 61 m (200 ft) in height, an additional grounding kit is installed at the tower midpoint. Additional ground kits are installed as necessary to reduce the distance between ground kits to 61 m (200 ft) or less.

• In high lightning prone geographical areas, additional ground kits are installed at intervals between 15 to 22 m (50 to 75 ft). This is especially important on towers taller than 45 m (150 ft).

Page 113: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Grounding and lightning protection

phn-2779_001v000 (Jul 2012) 2-11

Mast or tower protection diagrams

Figure 37 shows the protection requirements for an ODU mounted on a metal tower or mast.

Figure 38 shows the protection requirements for a 1+1 or 2+0 protected end.

Figure 37 Grounding and lightning protection on mast or tower

Page 114: Cambium network ptp 810 series 01 00 user guide

Grounding and lightning protection Chapter 2: Planning considerations

2-12 phn-2779_001v000 (Jul 2012)

Figure 38 Grounding and lightning protection on mast or tower (protected end)

Tower Ground Bar (TGB)

External Ground Bar (EGB)

Rack Ground Bar (RGB)

Equipment rack

MMU

Lightning Protection Units (LPUs)

Lightning Protection Units (LPUs)

Master Ground Bar (MGB)

Ground cable

Ground bus conductor

IF cable

First point of contact with tower

Mid-point of tower

Bottom of tower

Network cable

To network

Ground ring

Two ODUs and one antenna connected via coupler

Tower/building ground system

Protection requirements for the ODU on a high rise building

If the antenna or ODU is mounted on a high rise building, with cable entry at roof level (Figure 39) and the equipment inside (Figure 40), then ensure that the installation meets the following requirements:

• The antenna and ODU are below the lightning terminals and finials.

• A grounding conductor is installed around the roof perimeter, to form the main roof perimeter lightning protection ring.

• Air terminals are installed along the length of the main roof perimeter lightning protection ring typically every 6.1m (20ft).

• The main roof perimeter lightning protection ring contains at least two down conductors connected to the grounding electrode system. The down conductors are physically separated from one another, as far as practical.

Page 115: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Grounding and lightning protection

phn-2779_001v000 (Jul 2012) 2-13

Figure 39 Grounding and lightning protection on building

Page 116: Cambium network ptp 810 series 01 00 user guide

Grounding and lightning protection Chapter 2: Planning considerations

2-14 phn-2779_001v000 (Jul 2012)

Protection inside the building

Inside multi-story or high rise buildings (Figure 40), ensure that the installation meets the following requirements:

• The IF cable shield is bonded to the building grounding system at the entry point to the building.

• The IF cable shield is bonded to the building grounding system at the entry point to the equipment area.

• An LPU is installed within 600 mm (24 in) of the entry point to the equipment area.

Figure 40 Grounding and lightning protection inside high building

Page 117: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Grounding and lightning protection

phn-2779_001v000 (Jul 2012) 2-15

In a 1+1 Hot Standby protected end, prior to connecting MMUs via the protection interface, connect the front panel ground stud of both MMUs to a common ground (Figure 41).

Figure 41 Grounding and lightning protection inside high building (protected end)

Page 118: Cambium network ptp 810 series 01 00 user guide

Data network planning Chapter 2: Planning considerations

2-16 phn-2779_001v000 (Jul 2012)

Data network planning

When planning PTP 810 data networks, consider the factors described in this section.

IP interface

Choose an IP address for the IP interface of the MMU management agent. The IP address must be unique and valid for the connected network segment. Find out the correct subnet mask and gateway IP address for this network segment.

Ensure that the design of the data network permits bi-direction routing of IP datagrams between network management systems and the MMUs. For example, ensure that the gateway IP address identifies a router or other gateway that provides access to the rest of the data network.

Quality of service for bridged Ethernet traffic

Decide how quality of service will be configured in PTP 810 to minimize frame loss and latency for high priority traffic. Wireless links often have lower data capacity than wired links or network equipment like switches and routers, and quality of service configuration is most critical at network bottlenecks.

Classification rules

Select the classification rules based on Ethernet priority or IP priority to match QoS policy in the rest of the data network. Ethernet priority is also known as Layer 2 or link layer priority. IP priority is also known as Layer 3 or network layer priority.

QoS is implemented using weighted or strict priority queues. Incoming packets are assigned to a weighted priority queue based on one or more of the following criteria:

• Port Based Priority: packets are assigned to a priority queue based upon the port the packet arrives on.

• 802.1Q VLAN Tag Priority: packets are assigned to a priority queue based upon the priority tag field in the VLAN tag.

• Diffserv: packets are assigned to a priority queue based upon the value of the DSCP field of the IPv4 header.

Port based priority cannot be used at the same time as the 802.1Q VLAN Tag and Diffserv priority on the Standard Master I/O Module card.

Page 119: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Data network planning

phn-2779_001v000 (Jul 2012) 2-17

The installed Master I/O module determines which QoS configuration capabilities are supported:

• PTP 810 MMU Standard Master I/O module:

o Port Based Priority, 802.1Q VLAN Tag Priority and DiffServ Priority

o Four queues

o Weighted fair queuing scheme or Strict priority scheme

o Priority queues for weighted fair queuing scheme with fixed weights of 8, 4, 2 and 1

o Priority Resolution

• PTP 810 MMU GigE Master I/O module

o Port Based Priority, 802.1Q VLAN Tag Priority and DiffServ Priority

o Four queues

o Weighted fair queuing scheme

o Priority queues have user-configurable weights

o High Queue Preempt

o Priority Resolution

The two Master I/O modules available with the PTP 810 MMU support four priority queues (Figure 42). This capability applies to both Fast Ethernet and GigE Ethernet traffic.

Figure 42 PTP 810 MMU Ethernet QoS Priority Queue

PriorityResolution

Port Priority

802.1Q VLAN TagPriority

DiffServ

Priority Queue 1Priority Queue 2Priority Queue 3Priority Queue 4

Ethernet priority

Ethernet priority is encoded in a VLAN tag. Use the Ethernet priority if the network carries traffic in customer or service provider VLANs, and the priority in the VLAN tag has been set to indicate the priority of each type of traffic. Select a suitable mapping from the Ethernet priority to the four PTP 810 queues.

An advantage of Ethernet priority is that any VLAN-tagged frame can be marked with a priority, regardless of the higher-layer protocols contained within the frame. A disadvantage of Ethernet priority is that the priority in the frame must be regenerated whenever traffic passes through a router.

Page 120: Cambium network ptp 810 series 01 00 user guide

Data network planning Chapter 2: Planning considerations

2-18 phn-2779_001v000 (Jul 2012)

IP/Diffserv priority scheme

Diffserv is the Layer 3 Differentiated Services feature that uses the 6-bit Differentiated Services Code Point (DSCP) field in the IP header

IP priority is encoded in the DSCP field in an IPv4 or IPv6 header. The DSCP field provides 64 levels of priority. Determine the DSCP values used in the network and select a suitable mapping from these DSCP values to the four PTP 810 queues.

An advantage of IP priority is that priority in the IP header is normally propagated transparently through a router. Also, the DSCP field supports a large number of distinct priority code points. A disadvantage of DSCP is that frames receive a single default classification if they contain a network layer protocol other than IPv4 or IPv6.

Fast Ethernet port shutdown

If the PTP 810 link is part of a redundant network where STP is used in external Ethernet bridges in order to resolve loops in the data path, enable the Shutdown On Link Failure attribute to ensure that protection protocols are invoked promptly following loss of the wireless link.

Shutdown on link failure cannot be enabled unless RSTP is disabled in the MMU.

Page 121: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide TDM network planning

phn-2779_001v000 (Jul 2012) 2-19

TDM network planning

When planning PTP 810 TDM networks, consider the factors described in this section.

E1/T1 termination points and pass-through

The E1/T1 termination points at each site in a TDM network must be carefully planned. A termination point refers to a full E1/T1 physically connected to the MMU. The set of E1/T1 termination points include the Master IO Module front panel E1/T1 ports as well as the Expansion Module ports. E1/T1s may also pass-through the MMU from East to West radio ports in Dual 1+0 configurations.

The TDM switch capability is "any to any": E1/T1 ports configured over the East radio port can be connected to any E1/T1 port of the West radio port or to any E1/T1 port of the front panel. Moreover, an E1/T1 port of the front panel can be connected to any E1/T1 radio port or to another E1/T1 port of the front panel.

The maximum number of E1/T1 termination points that are supported by a PTP 810 MMU is dependent not only on the selection of the Master I/O module and Expansion I/O module, but on the channel bandwidth, modulation mode and link type (1+0/1+1, 2+0, Dual 1+0). All these dependencies are covered in detail in TDM bridging on page 1-57).

Planning the TDM network involves identifying the termination endpoints of each E1/T1 in the network and determining the primary and fallback (in the case of SNCP-like protected circuits) paths through the network. Once done, the number of E1/T1 circuits per link can be determined and planned based on the number of E1/T1 circuits that terminate or pass-through a given MMU.

Protection requirements

The architecture of a TDM network is also dependent on whether or not protection against link failure is required. For ribbon topologies that do not require protection, Dual 1+0 links can be deployed (see Dual 1+0 links on page 1-60). With Dual 1+0 links, a minimum of one PTP 810 MMU per site is required to pass E1/T1 circuits from one radio link to the other radio link in a ribbon topology without protection. The MMU at a given site can also be used to source and terminate E1/T1 circuits.

For ribbon topologies that require protection, 1+1 Hot Standby or 1+1 Hot Standby Spatial Diversity links can be deployed (see Planning 1+1 links on page 2-25). 1+1 links require the use of both the East and West modems of a PTP 810 MMU. Therefore, at least two MMUs per site are required to pass E1/T1 circuits from one radio link to the other radio link in a ribbon topology with protection.

Page 122: Cambium network ptp 810 series 01 00 user guide

TDM network planning Chapter 2: Planning considerations

2-20 phn-2779_001v000 (Jul 2012)

For ring topologies, SNCP-like protection can be used to create redundant routes using PTP 810 MMUs configured to support Dual 1+0 links (see SNCP-like protection on page 1-60). With SNCP-like protection, the TDM switch in the Master I/O module duplicates E1/T1 data from a single front panel port and transmits it on both the East and West modems. Duplicating each E1/T1 circuit sourced by a front panel port reduces the maximum number of E1/T1 circuits that can be supported versus a non-protected ring configuration.

The Standard Master I/O Module supports SNCP-like protection. The GigE Master I/O module supports SNCP-like protection only when it is configured to use the 4130_SGxx.xx.xx firmware image (see Installing new software versions on page 7-63).

2+0 link failover preference

In 2+0 links, the E1/T1 circuits carried by the East modem have preference if the East modem link fails (see Protection switching in 2+0 co-polar, cross-polar and XPIC on page 1-61). If the link supported by the East modem fails, the E1/T1 circuits mapped in the East modem are transferred to the West modem and all the E1/T1 circuits mapped to the West modem are dropped. This is an important consideration in planning 2+0 links. The number of E1/T1 circuits in a 2+0 link that require protection from being dropped will directly impact the number of E1/T1s on the East radio port that the PTP 810 MMUs at each end of the link will need to support. This will also impact the modulation mode and capacity license that need to be used.

It is possible to plan 2+0 links with E1/T1 circuits on just the East modem and use the West modem for Ethernet data. In this case, on East modem link failure, all E1/T1 circuits are transferred to the West modem, causing a loss of Ethernet throughput equivalent to the amount that the E1/T1 circuits use.

TDM and Ethernet traffic capacity tradeoffs

In network topologies that support both TDM and Ethernet traffic, there are other planning considerations. One consideration is that the choice of Master I/O module provides a tradeoff between TDM and Ethernet traffic capacity.

The Standard Master I/O module has an Ethernet switch that limits maximum Ethernet throughput capacity to 98.7 Mbps with a 1518 byte frame size. As a tradeoff, the Standard Master I/O module supports more E1/T1 front panel ports as well as a higher capacity TDM switch than the GigE Master I/O module.

The GigE Master I/O module has an Ethernet switch that limits the maximum Ethernet throughput capacity to 1000 Mbps, which is more than a 2+0 link can carry. This means that it is limited by the capacity of the modulation mode being used. It also supports link aggregation for 2+0 links. As a tradeoff, the GigE Master I/O module supports fewer E1/T1 front panel ports as well as a lower capacity TDM switch than the Standard Master I/O module.

Page 123: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide TDM network planning

phn-2779_001v000 (Jul 2012) 2-21

With either Master I/O module the total throughput traffic capacity is highly dependent on the modulation mode being used (see Capacity, transmit power and sensitivity on page 4-29). It also depends on the capacity license that has been purchased. For any modulation mode and Master I/O module, the traffic capacity of the E1/T1 circuits that are configured over either the East or West radio links is given priority over the Ethernet data traffic. The available Ethernet data traffic is effectively the traffic capacity that is still unused after E1/T1 traffic channels and Network Management traffic are accounted for. The PTP 810 MMU cannot be configured to prioritize Ethernet data traffic over TDM traffic.

The prioritization of E1/T1 circuits over Ethernet data traffic also holds true in the event of a link failure in a 2+0 topology as described above. If the link supported by the East modem fails, the E1/T1 circuits mapped in the East modem are transferred to the West modem, the E1/T1 circuits mapped to the West modem (if any) are dropped, and the remaining West modem Ethernet data traffic is the traffic capacity that is still unused after the E1/T1 traffic channels from the East modem and the Network Management traffic are accounted for.

Page 124: Cambium network ptp 810 series 01 00 user guide

Planning 1+0 links Chapter 2: Planning considerations

2-22 phn-2779_001v000 (Jul 2012)

Planning 1+0 links

When planning 1+0 links, follow the process described in this section.

Concept of a 1+0 link

A 1+0 link is the simplest link to deploy. There is no redundant equipment deployed and so costs are minimized. The 1+0 link provides no protection in the case of equipment failure. If a link is very critical to network operation and where a service outage due to equipment failure cannot be tolerated, consider deploying a 1+1 Hot Standby, 1+1 Host Standby Spatial Diversity or 2+0 link.

Antenna, ODU and MMU configurations for 1+0

Select one of the following 1+0 link end configurations:

• ODU with direct mount antenna (Figure 43).

• ODU with remote mount antenna (Figure 44).

Page 125: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Planning 1+0 links

phn-2779_001v000 (Jul 2012) 2-23

Figure 43 Schematic view of 1+0 ODU direct mount link end

ODU

MMU

Direct mount

antenna

IF cable

East modem

Page 126: Cambium network ptp 810 series 01 00 user guide

Planning 1+0 links Chapter 2: Planning considerations

2-24 phn-2779_001v000 (Jul 2012)

Figure 44 Schematic view of 1+0 ODU remote mount link end

ODU

Remote mount

antenna

RMK

Flexible waveguide

MMU

IF cable

East modem

Page 127: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Planning 1+1 links

phn-2779_001v000 (Jul 2012) 2-25

Planning 1+1 links

When planning 1+1 Hot Standby and 1+1 Hot Standby Spatial Diversity links, follow the process described in this section.

Concept of a 1+1 Hot Standby link

A 1+1 Hot Standby link provides protection against single point equipment failure of a Modem module, an IF cable, or an ODU. This is achieved by the deployment of extra equipment which automatically takes over the operation of the link in case of failure.

The two main advantages of a 1+1 Hot Standby link are:

• Better availability. In the unlikely event of equipment failure in one of the protected items, the 1+1 Hot Standby link becomes operational again with a down time of less than 250 ms. This is compared to a lengthy down time in the event of equipment failure in a 1+0 link. This may be particularly important in remote locations or for safety critical applications.

• Maintenance operations can be carried out with a minimum of interruption to the service provided by the link.

Concept of a 1+1 Hot Standby Spatial Diversity link

A 1+1 Hot Standby Spatial Diversity link provides protection against single point equipment failure similar to the 1+1 Hot Standby configuration described above, and additionally provides protection against multipath and clear-air multipath fading in the wireless link.

The spatial diversity configuration uses separate antennas for the two ODUs, and thus additionally provides protection against equipment failure of an ODU.

Page 128: Cambium network ptp 810 series 01 00 user guide

Planning 1+1 links Chapter 2: Planning considerations

2-26 phn-2779_001v000 (Jul 2012)

Antenna, ODU and MMU configurations for 1+1 links

Select one of the following 1+1 Hot Standby link end configurations:

ODUs coupled to single direct mount antenna

The coupler mounts directly to the back of the antenna (Figure 45).

Choose symmetric or asymmetric couplers. The asymmetric coupler provides a better link budget (nominally 6 dB) for the Primary ODUs at the expense of the link budget of the Secondary ODUs.

Figure 45 ODUs coupled to single direct mount antenna (schematic)

Secondary ODU

Primary ODU

Symmetric or asymmetric

coupler

IF cables

Direct mount antenna

MMU

East modemWest modem

Page 129: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Planning 1+1 links

phn-2779_001v000 (Jul 2012) 2-27

ODUs coupled to single remote mount antenna

Requires a Remote Mount Kit (RMK) to mount the Coupler and 3' of flexible waveguide to connect the RMK to the antenna (Figure 46).

Choose symmetric or asymmetric couplers. The asymmetric coupler provides a better link budget (nominally 6 dB) for the Primary ODUs at the expense of the link budget of the Secondary ODUs.

Figure 46 ODUs coupled to single remote mount antenna (schematic)

Secondary ODU

Primary ODU

IF cables

Remote mount antenna

Remote mount kit

Flexible waveguide

Symmetric or asymmetric

coupler

MMU

East modemWest modem

Page 130: Cambium network ptp 810 series 01 00 user guide

Planning 1+1 links Chapter 2: Planning considerations

2-28 phn-2779_001v000 (Jul 2012)

ODUs with separate direct mount antennas

May be used to provide Spatial Diversity. The ODUs mounts directly to the back of the antennas (Figure 47).

The antenna connected to the Secondary ODU may have lower gain if space on the mast is an issue. Although antennas may have different gains, the polarizations must be the same.

Figure 47 ODUs with separate direct mount antennas (schematic)

Primary ODU

Direct mount antenna

IF cable

Secondary ODU

Direct mount antenna

IF cable

MMU

East modemWest modem

Page 131: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Planning 1+1 links

phn-2779_001v000 (Jul 2012) 2-29

ODUs with separate remote mount antennas

May be used to provide Spatial Diversity. Each ODU is mounted using a Remote Mount Kit (Figure 48). Each RMK connects to its antenna with a 3' flexible waveguide.

The antenna connected to the Secondary ODU may have lower gain if space on the mast is an issue. Although antennas may have different gains, the polarizations must be the same.

Figure 48 ODUs with separate remote mount antennas (schematic)

Primary ODU

IF cable

Secondary ODU

IF cable

Remote mount antenna

Flexible waveguide

Remote mount antenna

Flexible waveguide

Remote mount

kits

MMU

East modemWest modem

Page 132: Cambium network ptp 810 series 01 00 user guide

Planning 1+1 links Chapter 2: Planning considerations

2-30 phn-2779_001v000 (Jul 2012)

Designating primary and secondary units

At each link end, the Primary ODU is the one connected to the East modem, and the Secondary ODU is the one connected to the West modem.

In deployments with asymmetric couplers, connect the Primary ODU to the arm of the coupler with lowest path loss. The coupler labels this arm as "Main".

If separate antennas are deployed, connect the Primary ODU to the antenna with the highest gain.

Link planning for 1+1 Hot Standby links

A 1+1 Hot Standby link has four radio paths:

• Primary end A to Primary end B

• Primary end A to Secondary end B

• Secondary end A to Primary end B

• Secondary end A to Secondary end B

A 1+1 Hot Standby link normally operates on the Primary to Primary radio path. However, any of the four paths may become active if a fault causes a protection switch at one end of the link. Use LINKPlanner to check wireless link availability for all four paths, ensuring that the minimum required availability can be met by all paths.

Link planning for Spatial Diversity

Spatial Diversity can significantly improve the availability of a link, particularly for long links. Indeed regulations can recommend or even mandate that Spatial Diversity is deployed for links which are longer than a specific range.

LINKPlanner calculates link availability for all link configurations and provides a very convenient way of seeing the effect of enabling Spatial Diversity.

Page 133: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Planning 2+0 links

phn-2779_001v000 (Jul 2012) 2-31

Planning 2+0 links

When planning 2+0 links, follow the process described in this section.

Concept of a 2+0 link

A 2+0 link consists of a single dual modem PTP 810 MMU at each end of the link. The MMUs are configured using either the “East/East” or “2+0 XPIC” ODU Operational Modes for 2+0 co-polar/cross-polar or 2+0 XPIC, respectively. These configurations allow for traffic to be sent over both modems of the MMU, effectively doubling the throughput. In the 2+0 co-polar/cross-polar cases, this results in two wireless links that must operate on different frequencies and so a separate license is generally required for each link. In the 2+0 XPIC case, the two wireless links operate on the same frequency.

When the MMUs have a GigE Master I/O module installed, they can be configured to provide link aggregation (see Transparent wireless link aggregation (GigE Master I/O module) on page 1-42) Link aggregation is used to automatically load balance traffic across the two wireless links. An external aggregation switch is required to provide equivalent load balancing for the Standard Master I/O module. For either Master I/O module, it is possible to use port based forwarding or RSTP/MSTP to segregate traffic between the two wireless links (see Managing 2+0 Co-Polar, Cross-Polar & XPIC links on page 7-25).

Antenna, ODU and MMU configurations for 2+0

Select one of the following 2+0 link end configurations:

Page 134: Cambium network ptp 810 series 01 00 user guide

Planning 2+0 links Chapter 2: Planning considerations

2-32 phn-2779_001v000 (Jul 2012)

ODUs coupled to single direct mount antenna - co-polar links

The Coupler mounts directly to the back of the antenna (Figure 49). Use the symmetric coupler with the 2+0 East-East configuration, as both links use the same bandwidth and modulation.

Figure 49 ODUs coupled to single direct mount antenna - co-polar links (schematic)

Link ‘A’ ODU

Coupler

IF cables

Direct mount antenna

(single polar)

Link ‘B’ ODU

MMU

East modemWest modem

Page 135: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Planning 2+0 links

phn-2779_001v000 (Jul 2012) 2-33

ODUs coupled to a single remote mount antenna - co-polar links

Requires a Remote Mount Kit (RMK) to mount the Coupler and 3' of flexible waveguide to connect the RMK to the antenna (Figure 50). Use the symmetric coupler with the 2+0 East-East configuration, as both links use the same bandwidth and modulation.

Figure 50 ODUs coupled to a single remote mount antenna - co-polar links (schematic)

Link ‘A’ ODU

Coupler

IF cables

Remote mount antenna

(single polar)

Link ‘B’ ODU

Flexible waveguide

Remote mount kit

MMU

East modemWest modem

Page 136: Cambium network ptp 810 series 01 00 user guide

Planning 2+0 links Chapter 2: Planning considerations

2-34 phn-2779_001v000 (Jul 2012)

ODUs coupled to a single direct mount antenna - cross-polar links

This configuration includes both 2+0 cross-polar and 2+0 XPIC configurations. It requires a dual-polar direct mount antenna (Figure 51).

To upgrade any standard antenna to dual-polar direct mount, purchasing an orthogonal mount kit from Cambium.

Figure 51 ODUs coupled to a single direct mount antenna - cross-polar links (schematic)

Page 137: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Planning 2+0 links

phn-2779_001v000 (Jul 2012) 2-35

ODUs connected to a dual polar remote mount antenna - cross-polar links

This configuration includes both 2+0 cross-polar and 2+0 XPIC configurations. It requires two Remote Mount Kits (RMK) to mount the ODUs and two 3' flexible waveguide to connect the RMKs to the antenna (Figure 52).

Figure 52 ODUs connected to a dual polar remote mount antenna - cross-polar links (schematic)

Link ‘A’ ODU

IF cables

Remote mount antenna (dual polar)

Link ‘B’ ODU

Remote mount

kits

Flexible waveguide

Flexible waveguide

MMU

East modemWest modem

Page 138: Cambium network ptp 810 series 01 00 user guide

Planning 2+0 links Chapter 2: Planning considerations

2-36 phn-2779_001v000 (Jul 2012)

Frequency spacing

For co-polar deployments, the transmit frequency of link A and link B at a given end must be separated by at least two channel separations. For example, if the channel separation is configured as 28 MHz, the spacing between the two transmit frequencies must be at least 56 MHz.

For cross-polar deployments where XPIC operation is not enabled, the transmit frequency of link A and link B at a given end must be separated by at least one channel separation. For example, if the channel separation is configured as 28 MHz, the spacing between the two transmit frequencies must be at least 28 MHz.

For cross-polar 2+0 XPIC deployments, the same transmit frequency must be used for link A and link B.

Page 139: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Planning Dual 1+0 links

phn-2779_001v000 (Jul 2012) 2-37

Planning Dual 1+0 links

When planning ring and ribbon topologies in a PTP 810 network using the Dual 1+0 configuration and LINKPlanner, follow the procedures in this section to update the BOM.

BOM for ring and ribbon topologies

The creation of a ribbon or ring topology in a PTP 810 01-00 system will make use of the Dual 1+0 configuration (East/West ODU operational mode) in the PTP 810 MMUs. The Dual 1+0 configuration uses a single PTP 810 MMU with dual modems at each site and is an unprotected configuration deploying 1+0 links.

LINKPlanner is only aware of each individual link. It will generate a BOM for each link without knowing that the PTP 810 MMU will have some redundant components that are shared at each site in a 1+0 ribbon or ring topology. The following planning considerations need to be taken into account to generate the correct BOM for these system topologies.

1+0 Ribbon topology

Along the chain of links used in a 1+0 ribbon topology, a single PTP 810 MMU is shared between two links for each site that is not one of the two end-points of the chain. Each PTP 810 that is not at the ends of the chain connects to a pair of ODUs, where each ODU interfaces to a separate modem module and a separate power supply module. All other PTP 810 MMU modules including the chassis, controller module, master I/O module and any expansion I/O module do not need to be duplicated.

The PTP 810 MMU base module configuration that is the correct choice to use for each shared site in a 1+0 ribbon topology chain is the dual modem base module configuration that is used with 1+1 and 2+0 links. Since each individual link in the chain is in a 1+0 configuration, LINKPlanner will generate a BOM consisting of two single modem PTP 810 MMU base modules and two expansion I/O modules (if used) for each shared site along the chain. The end result is the need to manually replace the two single modem base modules with one dual modem base module and delete the duplicate expansion I/O module for each shared site from the overall system BOM list. The capacity license keys used will need to be adjusted as well.

A 1+0 ribbon topology containing N links will consist of N+1 sites where N-1 of these sites will be shared sites. For each of these N-1 shared sites, the system planner will need to:

1 Replace the part number of one of the single modem base modules with the part number of the equivalent dual modem base module.

2 Delete the duplicate single modem base module and the duplicate expansion I/O module (if used) from the BOM generated by LINKPlanner.

Page 140: Cambium network ptp 810 series 01 00 user guide

Planning Dual 1+0 links Chapter 2: Planning considerations

2-38 phn-2779_001v000 (Jul 2012)

3 Double the capacity license key size.

1+0 Ring topology

From the perspective of the required PTP 810 MMU module configurations and the associated BOM generated by LINKPlanner, the 1+0 ring topology is very similar to the 1+0 ribbon topology. The main difference is that the end points are also connected, resulting in an topology where every site becomes a shared site.

A 1+0 ring containing N links will consist of N sites where each of these sites will be a shared site. For each of these N shared sites, the system planner will need to:

1 Replace the part number of one of the single modem base modules with the part number of the equivalent dual modem base module.

2 Delete the duplicate single modem base module and the duplicate expansion I/O module (if used) from the BOM generated by LINKPlanner.

3 Double the capacity license key size.

Page 141: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Ordering components

phn-2779_001v000 (Jul 2012) 2-39

Ordering components

This section describes how to select components for a planned PTP 810 link.

Ordering MMUs

Select MMUs and associated components from the following tables:

• Base modules: Table 8

• Spare, expansion and upgrade modules: Table 9

• Accessories: Table 10

Table 8 MMU base modules

Cambium part number

Description

C000081M001 PTP810 MMU Standard, 2xFE + 16xE1/T1

C000081M008 PTP810 MMU GigE, 4xGigE + 1xGigE SFP + 2xE1/T1

C000081M003 PTP810 MMU Standard Dual Modem, 2xFE + 16xE1/T1

C000081M005 PTP810 MMU GigE Dual Modem, 4xGigE + 1xGigE SFP + 2xE1/T1

Table 9 MMU spare, expansion and upgrade modules

Cambium part number

Description

N000081H005 PTP810 MMU Control Module

C000081H002 PTP810 MMU Modem Module

N000081H015 PTP810 MMU Power Supply Module

N000081H004 PTP810 MMU Chassis

N000081H016 PTP810 MMU Standard Master I/O module

N000081H012 PTP810 MMU GigE Master I/O module

N000081H006 PTP810 MMU Expansion I/O: 16xE1/T1

C000081H001 PTP810 MMU Dual Modem upgrade kit, Power Supply Module + Modem Module

Page 142: Cambium network ptp 810 series 01 00 user guide

Ordering components Chapter 2: Planning considerations

2-40 phn-2779_001v000 (Jul 2012)

Table 10 MMU accessories

Cambium part number

Description

N000081L002 PTP810 AC to DC power adapter

N000081L001 PTP810 14 to 1 Shielded E1/T1 cables, Bare Wire 10ft

N000081L004 PTP810 XPIC cable

N000081L005 TNC Male for CNT-400 braided cable

N000081L006 TNC Male Right Angle for CNT-400 braided cable

N000081L007 Type N Female to TNC Male Adapter

Ordering capacity upgrades and XPIC capability

MMU Modem Modules are shipped with a data throughput capacity of 10 Mbps and without XPIC capability. To increase the capacity or install XPIC capability, perform the following procedures:

• Order access keys.

• Use the access keys to generate authorization keys.

• Enter the authorization keys in the MMU web interface. The procedure is described in Entering an authorization key on page 7-60.

The MMU may not achieve the data throughput capacity specified in the access key, as its capacity also depends on channel bandwidth and modulation mode. For more information, see Capacity, transmit power and sensitivity on page 4-29.

Ordering access keys

Select either a single-step capacity upgrade from Table 11, or one or more step-by-step capacity upgrades from Table 12. For XPIC capability, select an XPIC upgrade key from Table 13.

Order these components from a Cambium authorized Point-To-Point dealer. The dealer will send one or more access keys by email.

Page 143: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Ordering components

phn-2779_001v000 (Jul 2012) 2-41

Table 11 Single-step capacity upgrades (per MMU)

Cambium part number

Description

WB3538 PTP800/PTP810 Modem Capacity CAP – 20 Mbps (per Unit)

WB3539 PTP800/PTP810 Modem Capacity CAP – 30 Mbps (per Unit)

WB3540 PTP800/PTP810 Modem Capacity CAP – 40 Mbps (per Unit)

WB3541 PTP800/PTP810 Modem Capacity CAP – 50 Mbps (per Unit)

WB3542 PTP800/PTP810 Modem Capacity CAP – 100 Mbps (per Unit)

WB3543 PTP800/PTP810 Modem Capacity CAP – 150 Mbps (per Unit)

WB3544 PTP800/PTP810 Modem Capacity CAP – 200 Mbps (per Unit)

WB3545 PTP800/PTP810 Modem Capacity CAP – 300 Mbps (per Unit)

WB3546 PTP800/PTP810 Modem Capacity CAP – 400 Mbps (per Unit)

N000081K001 PTP810 Modem Capacity CAP – 600 Mbps (per Unit)

Table 12 Step-by-step capacity upgrades (per MMU)

Cambium part number

Description

WB3547 PTP800/PTP810 Modem Capacity CAP upgrade from 20 -> 30 Mbps key (per Unit)

WB3548 PTP800/PTP810 Modem Capacity CAP upgrade from 30 -> 40 Mbps key (per Unit)

WB3549 PTP800/PTP810 Modem Capacity CAP upgrade from 40 -> 50 Mbps key (per Unit)

WB3550 PTP800/PTP810 Modem Capacity CAP upgrade from 50 -> 100 Mbps key (per Unit)

WB3551 PTP800/PTP810 Modem Capacity CAP upgrade from 100 -> 150 Mbps key (per Unit)

WB3552 PTP800/PTP810 Modem Capacity CAP upgrade from 150 -> 200 Mbps key (per Unit)

WB3553 PTP800/PTP810 Modem Capacity CAP upgrade from 200 -> 300 Mbps key (per Unit)

WB3554 PTP800/PTP810 Modem Capacity CAP upgrade from 300 -> 400 Mbps Key (per Unit)

Page 144: Cambium network ptp 810 series 01 00 user guide

Ordering components Chapter 2: Planning considerations

2-42 phn-2779_001v000 (Jul 2012)

Cambium part number

Description

N000081K003 PTP810 Modem Capacity CAP upgrade from 400 -> 600 Mbps Key (per Unit)

Table 13 XPIC capability (per MMU)

Cambium part number

Description

N000081K005 PTP810 MMU XPIC Authorization Key (per Unit)

Using access keys to generate authorization keys

When the MMU or Modem Module is delivered, proceed as follows for each access key ordered:

1 Obtain the MMU or Modem Module serial numbers:

For a capacity upgrade, obtain the MMU chassis serial number. This is recorded on the packing sheet and on the MMU enclosure (Figure 53).

For an XPIC capability upgrade, obtain the Modem Module serial numbers. This is recorded on the packing sheet (it is not visible on the Modem Modules).

Alternatively, log into the MMU via the web interface and obtain these serial numbers (see Viewing device information on page 7-57).

2 Go to the PTP web support page (see Contacting Cambium Networks on page 2).

3 Navigate to the Cambium Networks License Key Generator.

4 Enter the required details, including access keys and serial numbers.

4 Submit the web form. Cambium will send the authorization keys by email.

Figure 53 Location of chassis serial number on MMU enclosure

Page 145: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Ordering components

phn-2779_001v000 (Jul 2012) 2-43

If XPIC capability is not requested, PTP License Key Generator provides two authorization keys:

• 1+x: The “1+x” authorization key permits operation of 1+0, 1+1 HSB, and 1+1 HSB SD link configurations of the MMU.

• 2+0: The “2+0” authorization key permits operation of Dual 1+0, 2+0 Cross-Polar and 2+0 Co-Polar link configurations of the MMU.

If XPIC capability is requested, PTP License Key Generator provides three authorization keys; the “1+x”, “2+0” (as defined above) and:

• XPIC: The “XPIC” Authorization Key is used to allow operation of 2+0 XPIC link configurations of the MMU.

Page 146: Cambium network ptp 810 series 01 00 user guide

Ordering components Chapter 2: Planning considerations

2-44 phn-2779_001v000 (Jul 2012)

Ordering antennas

Use Table 14 to select the type and quantity of antennas required per link.

Table 14 Selecting antennas for each hardware configuration

Hardware configuration

Antenna mounting Antenna protection?

Antenna polarization

Quantity per link

1+0 Direct or remote - Single (*1) 2

1+1 Direct or remote No Single 2

1+1 Direct or remote Yes Single 4

2+0 co-polar Direct or remote - Single 2

2+0 cross-polar Direct or remote (*2) - Dual 2

(*1) Select single-polar antennas (direct or remote mount) for normal 1+0 links. Alternatively, to provide for a future upgrade from 1+0 to 2+0, select dual-polar remote mount antennas.

(*2) As an alternative to purchasing a dual-polar direct mount antenna, use an orthogonal mount kit (OMK) to upgrade any standard antenna to dual-polar direct mount; refer to Ordering OMKs on page 2-75.

Select antennas from the following tables:

• Lower 6 GHz and Upper 6 GHz: Table 15 and Table 16.

• 7 GHz and 8 GHz: Table 17 and Table 18.

• 11 GHz: Table 19 and Table 20.

• 13 GHz: Table 21 and Table 22.

• 15 GHz: Table 23 and Table 24.

• 18 GHz: Table 25 and Table 26.

• 23 GHz: Table 27 and Table 28.

• 26 GHz: Table 29 and Table 30.

• 28 GHz: Table 31 and Table 32.

• 32 GHz: Table 33 and Table 34.

• 38 GHz: Table 35 and Table 36.

• Parabolic radomes (optional): Table 37.

In the Interface column of these tables, ‘Direct’ means Cambium direct mount and a flange size, for example ‘PDR70’, means remote mount.

Page 147: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Ordering components

phn-2779_001v000 (Jul 2012) 2-45

Table 15 Antennas: 6 GHz single polarization

Cambium number

Diameter Interface Mid-band gain

Vertical beamwidth

Weight

85009298001 1.0 m (3 ft) Direct 33 dBi 3.3° 24 kg (53 lb)

85010089050 1.2 m (4 ft) Direct 35 dBi 2.9° 55 kg (121 lb)

85010089021 1.8 m (6 ft) Direct 39 dBi 1.8° 62 kg (137 lb)

85010091022 1.0 m (3 ft) PDR70 33 dBi 3.3° 24 kg (53 lb)

85010091024 1.2 m (4 ft) PDR70 35 dBi 2.9° 55 kg (121 lb)

85010091007 1.8 m (6 ft) PDR70 39 dBi 1.8° 62 kg (137 lb)

85009294001 1.8 m (6 ft) CPR137G 38.2 dBi 1.9° 78 kg (172 lb)

85009294002 2.4 m (8 ft) CPR137G 40.8 dBi 1.4° 114 kg (251 lb)

85009294003 3 m (10 ft) CPR137G 43.4 dBi 1.1° 144 kg (317 lb)

85009294004 3.7 m (12 ft) CPR137G 44.9 dBi 0.9° 245 kg (540 lb)

Table 16 Antennas: 6 GHz dual polarization

Cambium number

Diameter Interface Mid-band gain

Vertical beamwidth

Weight

85009302001 1.0 m (3 ft) Direct (*) 33 dBi 3.3°

85009302002 1.2 m (4 ft) Direct (*) 35 dBi 2.9°

85009302003 1.8 m (6 ft) Direct (*) 39 dBi 1.8°

85010092048 1.0 m (3 ft) PDR70 33 dBi 3.3° 24 kg (53 lb)

85010092060 1.2 m (4 ft) PDR70 35 dBi 2.9° 55 kg (121 lb)

85010092021 1.8 m (6 ft) PDR70 39 dBi 1.8° 62 kg (137 lb)

(*) The antenna includes an orthogonal mode transducer.

Page 148: Cambium network ptp 810 series 01 00 user guide

Ordering components Chapter 2: Planning considerations

2-46 phn-2779_001v000 (Jul 2012)

Table 17 Antennas: 7 GHz and 8 GHz single polarization

Cambium number

Diameter Interface Mid-band gain

Vertical beamwidth

Weight

85010089045 0.6 m (2 ft) Direct 31.1 dBi 4.7° 11 kg (25 lb)

85009298002 1.0 m (3 ft) Direct 35.5 dBi 2.6° 24 kg (53 ib)

85010089051 1.2 m (4 ft) Direct 37.3 dBi 2.2° 55 kg (121 lb)

85010089025 1.8 m (6 ft) Direct 40.8 dBi 1.5° 62 kg (137 lb)

85010091020 0.6 m (2 ft) PDR84 31.1 dBi 4.7° 11 kg (25 lb)

85010091023 1.0 m (3 ft) PDR84 35.5 dBi 2.6° 24 kg (53 lb)

85010091025 1.2 m (4 ft) PDR84 37.3 dBi 2.2° 55 kg (121 lb)

85010091011 1.8 m (6 ft) PDR84 40.8 dBi 1.5° 62 kg (137 lb)

Table 18 Antennas: 7 GHz and 8 GHz dual polarization

Cambium number

Diameter Interface Mid-band gain

Vertical beamwidth

Weight

85009303001 0.6 m (2 ft) Direct (*) 31.1 dBi 4.7°

85009303002 1.0 m (3 ft) Direct (*) 35.5 dBi 2.6°

85009303003 1.2 m (4 ft) Direct (*) 37.3 dBi 2.2°

85009303004 1.8 m (6 ft) Direct (*) 40.6 dBi 1.5 °

85010092051 0.6 m (2 ft) PDR84 31.1 dBi 4.7° 14 kg (31 lb)

85010092059 1.0 m (3 ft) PDR84 35.5 dBi 2.6° 24 kg (53 lb)

85010092061 1.2 m (4 ft) PDR84 37.3 dBi 2.2° 55 kg (121 lb)

85010092025 1.8 m (6 ft) PDR84 40.6 dBi 1.5 ° 62 kg (137 lb)

(*) The antenna includes an orthogonal mode transducer.

Page 149: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Ordering components

phn-2779_001v000 (Jul 2012) 2-47

Table 19 Antennas: 11 GHz single polarization

Cambium number

Diameter Interface Mid-band gain

Vertical beamwidth

Weight

85010089049 0.6 m (2 ft) Direct 34.5 dBi 3.3° 11 kg (25 lb)

85010089003 0.8 m (2.6 ft) Direct 37.4 dBi 2.1° 30 kg (66 lb)

85009298003 1.0 m (3 ft) Direct 38.4 dBi 2.0° 24 kg (53 lb)

85010089052 1.2 m (4 ft) Direct 40.4 dBi 1.5° 46 kg (101 lb)

85010089005 1.8 m (6 ft) Direct 43.8 dBi 1.1° 84 kg (185 lb)

85010091019 0.6 m (2 ft) PDR100 (*1) 34.5 dBi 3.3° 11 kg (25 lb)

85010091003 0.8 m (2.6 ft) PDR100 (*1) 37.4 dBi 2.1° 30 kg (66 lb)

85010091017 1.0 m (3 ft) PDR100 (*1) 38.4 dBi 2.0° 24 kg (53 lb)

85010091026 1.2 m (4 ft) PDR100 (*1) 40.4 dBi 1.5° 46 kg (101 lb)

85010091005 1.8 m (6 ft) PDR100 (*1) 43.8 dBi 1.1° 84 kg (185 lb)

85009301001 1.2 m (4 ft) CPR90G (*1) 40.4 dBi 1.6° 69 kg (152 lb)

85009294005 1.8 m (6 ft) CPR90G (*1) 43.6 dBi 1.1° 78 kg (171 lb)

85009294006 2.4 m (8 ft) CPR90G (*1) 46.2 dBi 0.8° 125 kg (276lb)

(*1) Waveguide interface 11 GHz antennas require a tapered transition (Table 56).

Table 20 Antennas: 11 GHz dual polarization

Cambium number

Diameter Interface Mid-band gain

Vertical beamwidth

Weight

85009304001 0.6 m (2 ft) Direct (*1) 34.5 dBi 3.3°

85009304002 1.0 m (3 ft) Direct (*1) 38.4 dBi 2.0°

85009304003 1.2 m (4 ft) Direct (*1) 40.4 dBi 1.5°

85009304004 1.8 m (6 ft) Direct (*1) 43.8 dBi 1.1°

85010092052 0.6 m (2 ft) PDR100 (*2) 34.5 dBi 3.3° 11 kg (25 lb)

85010092003 0.8 m (2.6 ft) PDR100 (*2) 37.2 dBi 2.1° 30 kg (66 lb)

85010092042 1.0 m (3 ft) PDR100 (*2) 38.4 dBi 2.0° 24 kg (53 lb)

85010092062 1.2 m (4 ft) PDR100 (*2) 40.4 dBi 1.5° 46 kg (101 lb)

85010092005 1.8 m (6 ft) PDR100 (*2) 43.8 dBi 1.1° 84 kg (185 lb)

Page 150: Cambium network ptp 810 series 01 00 user guide

Ordering components Chapter 2: Planning considerations

2-48 phn-2779_001v000 (Jul 2012)

(*1) The antenna includes an orthogonal mode transducer.

(*2) Waveguide interface 11 GHz antennas require a tapered transition (Table 56).

The 11 GHz waveguide interface antennas require an extra component, the 11 GHz tapered transition. This is supplied by Cambium (Table 56) and is required to convert between the antenna interface and the waveguide flange.

Table 21 Antennas: 13 GHz single polarization

Cambium number

Diameter Interface Mid-band gain

Vertical beamwidth

Weight

85010089053 0.3 m (1 ft) Direct 30.9 dBi 4.7° 7 kg (15 lb)

85010089046 0.6 m (2 ft) Direct 36.0 dBi 2.7° 11 kg (25 lb)

85009298004 1.0 m (3 ft) Direct 40.0 dBi 1.6° 24 kg (53 lb)

85010089054 1.2 m (4 ft) Direct 42.0 dBi 1.3° 55 kg (121 lb)

85010089030 1.8 m (6 ft) Direct 45.2 dBi 0.9° 62 kg (137 lb)

85010091012 0.3 m (1 ft) PBR120 30.9 dBi 4.7° 7 kg (15 lb)

85010091021 0.6 m (2 ft) PBR120 36.0 dBi 2.7° 11 kg (25 lb)

85010091018 1.0 m (3 ft) PBR120 40.0 dBi 1.6° 24 kg (53 lb)

85010091027 1.2 m (4 ft) PBR120 42.0 dBi 1.3° 55 kg (121 lb)

85010091016 1.8 m (6 ft) PBR120 45.2 dBi 0.9° 62 kg (137 lb)

Table 22 Antennas: 13 GHz dual polarization

Cambium number

Diameter Interface Mid-band gain

Vertical beamwidth

Weight

85009305001 0.3 m (1 ft) Direct (*) 30.9 dBi 4.7°

85009305002 0.6 m (2 ft) Direct (*) 36.0 dBi 2.7°

85009305003 1.0 m (3 ft) Direct (*) 40.0 dBi 1.6°

85009305004 1.2 m (4 ft) Direct (*) 42.0 dBi 1.3°

85009305005 1.8 m (6 ft) Direct (*) 45.2 dBi 0.9°

85010092026 0.3 m (1 ft) PBR120 30.9 dBi 4.7° 7 kg (15 lb)

85010092056 0.6 m (2 ft) PBR120 36.0 dBi 2.7° 11 kg (25 lb)

85010092043 1.0 m (3 ft) PBR120 40.0 dBi 1.6° 24 kg (53 lb)

Page 151: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Ordering components

phn-2779_001v000 (Jul 2012) 2-49

Cambium number

Diameter Interface Mid-band gain

Vertical beamwidth

Weight

85010092063 1.2 m (4 ft) PBR120 42.0 dBi 1.3° 55 kg (121 lb)

85010092030 1.8 m (6 ft) PBR120 45.2 dBi 0.9° 62 kg (137 lb)

(*) The antenna includes an orthogonal mode transducer.

Table 23 Antennas: 15 GHz single polarization

Cambium number

Diameter Interface Mid-band gain

Vertical beamwidth

Weight

85010089055 0.3 m (1 ft) Direct 32.1 dBi 4.3° 7 kg (15 lb)

85010089047 0.6 m (2 ft) Direct 36.8 dBi 2.5 ° 11 kg (25 lb)

85009298005 1.0 m (3 ft) Direct 41.1 dBi 1.5° 24 kg (53 lb)

85010089056 1.2 m (4 ft) Direct 42.9 dBi 1.2° 55 kg (121 lb)

85010089035 1.8 m (6 ft) Direct 46.2 dBi 0.8° 62 kg (137 lb)

Table 24 Antennas: 15 GHz dual polarization

Cambium number

Diameter Interface Mid-band gain

Vertical beamwidth

Weight

85009306001 0.3 m (1 ft) Direct (*) 32.0 dBi 4.3°

85009306002 0.6 m (2 ft) Direct (*) 36.8 dBi 2.5°

85009306003 1.0 m (3 ft) Direct (*) 41.1 dBi 1.5°

85009306004 1.2 m (4 ft) Direct (*) 42.9 dBi 1.2°

85009306005 1.8 m (6 ft) Direct (*) 46.2 dBi 0.8°

85010092031 0.3 m (1 ft) PBR140 32.0 dBi 4.3° 7 kg (15 lb)

85010092057 0.6 m (2 ft) PBR140 36.8 dBi 2.5° 11 kg (25 lb)

85010092044 1.0 m (3 ft) PBR140 41.1 dBi 1.5° 24 kg (53 lb)

85010092064 1.2 m (4 ft) PBR140 42.9 dBi 1.2° 55 kg (121 lb)

85010092035 1.8 m (6 ft) PBR140 46.2 dBi 0.8° 62 kg (137 lb)

(*) The antenna includes an orthogonal mode transducer.

Page 152: Cambium network ptp 810 series 01 00 user guide

Ordering components Chapter 2: Planning considerations

2-50 phn-2779_001v000 (Jul 2012)

Table 25 Antennas: 18 GHz single polarization

Cambium number

Diameter Interface Mid-band gain

Vertical beamwidth

Weight

85010089057 0.3 m (1 ft) Direct 34.2 dBi 3.3° 6 kg (13 lb)

85010089042 0.6 m (2 ft) Direct 38.9 dBi 2.1° 11 kg (25 lb)

85009298006 1.0 m (3 ft) Direct 43.5 dBi 1.1° 24 kg (53 lb)

85010089058 1.2 m (4 ft) Direct 44.7 dBi 0.9° 46 kg (101 lb)

85010089010 1.8 m (6 ft) Direct 47.8 dBi 0.7° 84 kg (185 lb)

Table 26 Antennas: 18 GHz dual polarization

Cambium number

Diameter Interface Mid-band gain

Vertical beamwidth

Weight

85009307001 0.3 m (1 ft) Direct (*) 34.2 dBi 3.3°

85009307002 0.6 m (2 ft) Direct (*) 38.9 dBi 2.1°

85009307003 1.0 m (3 ft) Direct (*) 43.5 dBi 1.1°

85009307004 1.2 m (4 ft) Direct (*) 44.7 dBi 0.9°

85009307005 1.8 m (6 ft) Direct (*) 47.6 dBi 0.7°

85010092006 0.3 m (1 ft) PBR220 34.2 dBi 3.3° 6 kg (13 lb)

85010092053 0.6 m (2 ft) PBR220 38.9 dBi 2.1° 11 kg (25 lb)

85010092045 1.0 m (3 ft) PBR220 43.5 dBi 1.1° 24 kg (53 lb)

85010092065 1.2 m (4 ft) PBR220 44.7 dBi 0.9° 46 kg (101 lb)

85010092010 1.8 m (6 ft) PBR220 47.6 dBi 0.7° 84 kg (185 lb)

(*) The antenna includes an orthogonal mode transducer.

Page 153: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Ordering components

phn-2779_001v000 (Jul 2012) 2-51

Table 27 Antennas: 23 GHz single polarization

Cambium number

Diameter Interface Mid-band gain

Vertical beam -width

Weight

85010089059 0.3 m (1 ft) Direct 35.3 dBi 3.0° 6 kg (13 lb)

85010089043 0.6 m (2 ft) Direct 40.5 dBi 1.7° 11 kg (25 lb)

85009298007 1.0 m (3 ft) Direct 44.8 dBi 1.0° 24 kg (53 lb)

85010089060 1.2 m (4 ft) Direct 46.7 dBi 0.8° 46 kg (101 lb)

85010089015 1.8 m (6 ft) Direct 49.4 dBi 0.5° 84 kg (185 lb)

Table 28 Antennas: 23 GHz dual polarization

Cambium number

Diameter Interface Mid-band gain

Vertical beam -width

Weight

85009308001 0.3 m (1 ft) Direct (*) 35.3 dBi 3.0°

85009308002 0.6 m (2 ft) Direct (*) 40.5 dBi 1.7°

85009308003 1.0 m (3 ft) Direct (*) 44.8 dBi 1.0°

85009308004 1.2 m (4 ft) Direct (*) 46.7 dBi 0.8°

85009308005 1.8 m (6 ft) Direct (*) 49.2 dBi 0.5°

85010092011 0.3 m (1 ft) PBR220 35.3 dBi 3.0° 6 kg (13 lb)

85010092054 0.6 m (2 ft) PBR220 40.5 dBi 1.7° 11 kg (25 lb)

85010092046 1.0 m (3 ft) PBR220 44.8 dBi 1.0° 24 kg (53 lb)

85010092066 1.2 m (4 ft) PBR220 46.7 dBi 0.8° 46 kg (101 lb)

85010092015 1.8 m (6 ft) PBR220 49.2 dBi 0.5° 84 kg (185 lb)

(*) The antenna includes an orthogonal mode transducer.

Page 154: Cambium network ptp 810 series 01 00 user guide

Ordering components Chapter 2: Planning considerations

2-52 phn-2779_001v000 (Jul 2012)

Table 29 Antennas: 26 GHz single polarization

Cambium number

Diameter Interface Mid-band gain

Vertical beam- width

Weight

85010089061 0.3 m (1 ft) Direct 36.6 dBi 2.5° 6 kg (13 lb)

85010089044 0.6 m (2 ft) Direct 41.6 dBi 1.5° 11 kg (25 lb)

85009298008 1.0 m (3 ft) Direct 45.8 dBi 0.8° 24 kg (53 lb)

85010089062 1.2 m (4 ft) Direct 47.4 dBi 0.6° 46 kg (101 lb)

Table 30 Antennas: 26 GHz dual polarization

Cambium number

Diameter Interface Mid-band gain

Vertical beam-width

Weight

85010092016 0.3 m (1 ft) PBR220 36.6 dBi 2.5° 6 kg (13 lb)

85010092055 0.6 m (2 ft) PBR220 41.6 dBi 1.5° 11 kg (25 lb)

85010092047 1.0 m (3 ft) PBR220 45.8 dBi 0.8° 24 kg (53 lb)

85010092067 1.2 m (4 ft) PBR220 47.4 dBi 0.6° 46 kg (101 lb)

Table 31 Antennas: 28 GHz single polarization

Cambium number

Diameter Interface Mid-band gain

Vertical beam-width

Weight

85010089064 0.3 m (1 ft) Direct 38.1 dBi 2.2° 7 kg (14 lb)

85010089041 0.6 m (2 ft) Direct 42.6 dBi 1.2° 11 kg (25 lb)

Table 32 Antennas: 28 GHz dual polarization

Cambium number

Diameter Interface Mid-band gain

Vertical beam-width

Weight

85010092040 0.3 m (1 ft) PBR320 38.1 dBi 2.2° 7 kg (14 lb)

85010092041 0.6 m (2 ft) PBR320 42.6 dBi 1.2° 11 kg (25 lb)

Page 155: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Ordering components

phn-2779_001v000 (Jul 2012) 2-53

Table 33 Antennas: 32 GHz single polarization

Cambium number

Diameter Interface Mid-band gain

Vertical beam-width

Weight

85010089036 0.3 m (1 ft) Direct 38.9 dBi 1.8° 7 kg (14 lb)

85010089037 0.6 m (2 ft) Direct 43.5 dBi 1.0° 11 kg (25 lb)

Table 34 Antennas: 32 GHz dual polarization

Cambium number

Diameter Interface Mid-band gain

Vertical beam-width

Weight

85010092036 0.3 m (1 ft) PBR320 38.9 dBi 1.8° 7 kg (14 lb)

85010092037 0.6 m (2 ft) PBR320 43.5 dBi 1.0° 11 kg (25 lb)

Table 35 Antennas: 38 GHz single polarization

Cambium number

Diameter Interface Mid-band gain

Vertical beam-width

Weight

85010089063 0.3 m (1 ft) Direct 40.1 dBi 1.6° 6 kg (13 lb)

85010089048 0.6 m (2 ft) Direct 45.2 dBi 0.9° 11 kg (25 lb)

Table 36 Antennas: 38 GHz dual polarization

Cambium number

Diameter Interface Mid-band gain

Vertical beam-width

Weight

85010092038 0.3 m (1 ft) PBR320 40.1 dBi 1.6° 7 kg (15 lb)

85010092058 0.6 m (2 ft) PBR320 45.2 dBi 0.9° 11 kg (25 lb)

Page 156: Cambium network ptp 810 series 01 00 user guide

Ordering components Chapter 2: Planning considerations

2-54 phn-2779_001v000 (Jul 2012)

Table 37 Parabolic radomes (optional)

Cambium number

Description

85009295001 10 Foot Radome For Par10 Antenna

85009295002 11 Foot Radome For Par12 Antenna

Ordering ODUs

Determine the number of ODUs required per link, as follows:

• 1+0 links: 2 ODUs.

• 1+1 Hot Standby links: 4 ODUs.

• 2+0 links: 4 ODUs.

Select ODUs from the following tables:

• Lower 6 GHz: Table 38.

• Upper 6 GHz: Table 39.

• 7 GHz: Table 40.

• 8 GHz: Table 41.

• 11 GHz: Table 42 (ODU-B) and Table 43 (ODU-A).

• 13 GHz: Table 44.

• 15 GHz: Table 45.

• 18 GHz: Table 46 (ODU-B) and Table 47 (ODU-A).

• 23 GHz: Table 48 (ODU-B) and Table 49 (ODU-A).

• 26 GHz: Table 50.

• 28 GHz: Table 51.

• 32 GHz: Table 52.

• 38 GHz: Table 53.

If ODU-B is available (11, 18 and 23 GHz), choose it in preference to ODU-A. Do not install ODU-A and ODU-B in the same link.

Page 157: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Ordering components

phn-2779_001v000 (Jul 2012) 2-55

Table 38 ODUs: Lower 6 GHz ODU-A

Cambium part number

Standard Sub-band

Sub-band frequency T/R spacing

01010411007 FCC, ETSI

B1-Lo 5925 – 6025 MHz 252 MHz

01010411008 B1-Hi 6175 – 6275 MHz

01010411009 B2-Lo 6000 – 6100 MHz

01010411010 B2-Hi 6250 – 6350 MHz

01010411011 B3-Lo 6075 – 6175 MHz

01010411012 B3-Hi 6325 – 6425 MHz

Table 39 ODUs: Upper 6 GHz ODU-A

Cambium part number

Standard Sub-band

Sub-band frequency T/R spacing

01010411024 FCC B1-Lo 6580 – 6640 MHz 160 MHz

01010411022 B1-Hi 6740 – 6800 MHz

01010411025 B2-Lo 6640 – 6710 MHz

01010411023 B2-Hi 6800 – 6870 MHz

01010411027 FCC B1-Lo 6530 – 6580 MHz 170 MHz

01010411026 B1-Hi 6700 – 6750 MHz

01010411013 ETSI B1-Lo 6430 – 6540 MHz 340 MHz

01010411014 B1-Hi 6770 – 6880 MHz

01010411015 B2-Lo 6520 – 6630 MHz

01010411016 B2-Hi 6860 – 6970 MHz

01010411017 B3-Lo 6600 – 6710 MHz

01010411018 B3-Hi 6940 – 7050 MHz

01010411019 B4-Lo 6670 – 6780 MHz

01010411020 B4-Hi 7010 – 7120 MHz

Page 158: Cambium network ptp 810 series 01 00 user guide

Ordering components Chapter 2: Planning considerations

2-56 phn-2779_001v000 (Jul 2012)

Table 40 ODUs: 7 GHz ODU-A

Cambium part number

Standard Sub-band

Sub-band frequency T/R spacing

01010610001 ETSI B1-Lo 7428 – 7484 MHz 154 MHz

01010610002 B1-Hi 7582 – 7638 MHz

01010610003 B2-Lo 7470 – 7526 MHz

01010610004 B2-Hi 7624 – 7680 MHz

01010610005 B3-Lo 7512 – 7568 MHz

01010610006 B3-Hi 7666 – 7722 MHz

01010610013 ETSI B1-Lo 7114 – 7177 MHz 161 MHz

01010610014 B1-Hi 7275 – 7338 MHz

01010610015 B2-Lo 7149 – 7212 MHz

01010610016 B2-Hi 7310 – 7373 MHz

01010610017 B3-Lo 7184 – 7247 MHz

01010610018 B3-Hi 7345 – 7408 MHz

01010610019 B4-Lo 7219 – 7282 MHz

01010610020 B4-Hi 7380 – 7443 MHz

01010610021 B5-Lo 7239 – 7302 MHz

01010610022 B5-Hi 7400 – 7463 MHz

01010610023 B6-Lo 7274 – 7337 MHz

01010610024 B6-Hi 7435 – 7498 MHz

01010610025 B7-Lo 7309 – 7372 MHz

01010610026 B7-Hi 7470 – 7533 MHz

01010610027 B8-Lo 7344 – 7407 MHz

01010610028 B8-Hi 7505 – 7568 MHz

01010610029 B9-Lo 7414 – 7477 MHz

01010610030 B9-Hi 7575 – 7638 MHz

01010610031 B10-Lo 7449 – 7512 MHz

01010610032 B10-Hi 7610 – 7673 MHz

01010610033 B21-Lo 7484 – 7547 MHz

Page 159: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Ordering components

phn-2779_001v000 (Jul 2012) 2-57

Cambium part number

Standard Sub-band

Sub-band frequency T/R spacing

01010610034 B21-Hi 7645 – 7708 MHz

01010610035 B22-Lo 7519 – 7582 MHz

01010610036 B22-Hi 7680 – 7743 MHz

01010610037 B23-Lo 7539 – 7602 MHz

01010610038 B23-Hi 7700 – 7763 MHz

01010610039 B24-Lo 7574 – 7637 MHz

01010610040 B24-Hi 7735 – 7798 MHz

01010610041 B25-Lo 7609 – 7672 MHz

01010610042 B25-Hi 7770 – 7833 MHz

01010610043 B26-Lo 7644 – 7707 MHz

01010610044 B26-Hi 7805 – 7868 MHz

01010610062 ETSI B1-Lo 7443 – 7499 MHz 168 MHz

01010610063 B1-Hi 7611 – 7667 MHz

01010610064 B2-Lo 7485 – 7541 MHz

01010610065 B2-Hi 7653 – 7709 MHz

01010610066 B3-Lo 7527 – 7583 MHz

01010610067 B3-Hi 7695 – 7751 MHz

01010610045 ETSI B1-Lo 7093 – 7149 MHz 196 MHz

01010610046 B1-Hi 7289 – 7345 MHz

01010610047 B2-Lo 7121 – 7177 MHz

01010610048 B2-Hi 7317 – 7373 MHz

01010610049 B3-Lo 7149 – 7205 MHz

01010610050 B3-Hi 7345 – 7401 MHz

01010610051 B4-Lo 7177 – 7233 MHz

01010610052 B4-Hi 7373 – 7429 MHz

01010610053 B5-Lo 7205 – 7261 MHz

01010610054 B5-Hi 7401 – 7457 MHz

01010610055 ETSI B1-Lo 7400 – 7484 MHz 245 MHz

01010610056 B1-Hi 7645 – 7729 MHz

Page 160: Cambium network ptp 810 series 01 00 user guide

Ordering components Chapter 2: Planning considerations

2-58 phn-2779_001v000 (Jul 2012)

Cambium part number

Standard Sub-band

Sub-band frequency T/R spacing

01010610057 B2-Lo 7484 – 7568 MHz

01010610058 B2-Hi 7729 – 7813 MHz

01010610059 B3-Lo 7568 – 7652 MHz

01010610060 B3-Hi 7813 – 7897 MHz

Table 41 ODUs: 8 GHz ODU-A

Cambium part number

Standard Sub-band

Sub-band frequency T/R spacing

01010611001 ETSI B1-Lo 8279 – 8307 MHz 119 MHz

01010611002 B1-Hi 8398 – 8426 MHz

01010611003 B2-Lo 8293 – 8321 MHz

01010611004 B2-Hi 8412 – 8440 MHz

01010611005 B3-Lo 8307 – 8335 MHz

01010611006 B3-Hi 8426 – 8454 MHz

01010611007 B4-Lo 8321 – 8349 MHz

01010611008 B4-Hi 8440 – 8468 MHz

01010611009 B5-Lo 8335 – 8363 MHz

01010611010 B5-Hi 8454 – 8482 MHz

01010611011 B6-Lo 8349 – 8377 MHz

01010611012 B6-Hi 8468 – 8496 MHz

01010611019 ETSI B1-Lo 8043 – 8113 MHz 208 MHz

01010611020 B1-Hi 8251 – 8321 MHz

01010611021 B2-Lo 8099 – 8169 MHz

01010611022 B2-Hi 8307 – 8377 MHz

01010611023 B3-Lo 8155 – 8225 MHz

01010611024 B3-Hi 8363 – 8433 MHz

01010611025 B4-Lo 8211 – 8281 MHz

01010611026 B4-Hi 8419 – 8489 MHz

01010611027 ETSI B1-Lo 7905 – 8024 MHz 266 MHz

01010611028 B1-Hi 8171 – 8290 MHz

Page 161: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Ordering components

phn-2779_001v000 (Jul 2012) 2-59

Cambium part number

Standard Sub-band

Sub-band frequency T/R spacing

01010611029 B2-Lo 8017 – 8136 MHz

01010611030 B2-Hi 8283 – 8402 MHz

01010611031 ETSI B2-Lo 7835 – 7971 MHz 311 MHz

01010611032 B2-Hi 8146 – 8282 MHz

01010611033 B3-Lo 7717 – 7867 MHz

01010611034 B3-Hi 8028 – 8178 MHz

Table 42 ODUs: 11 GHz ODU-B

Cambium part number

Standard Sub-band Sub-band frequency

T/R spacing

85009317001 FCC B5-Lo 10700 – 10890 MHz 490 MHz

85009317002 B5-Hi 11200 – 11390 MHz

85009317003 B6-Lo 10855 – 11045 MHz

85009317004 B6-Hi 11355 – 11545 MHz

85009317005 B7-Lo 11010 – 11200 MHz

85009317006 B7-Hi 11510 – 11700 MHz

Table 43 ODUs: 11 GHz ODU-A

Cambium part number

Standard Sub-band Sub-band frequency T/R spacing

01010208001 FCC, ETSI

B5-Lo 10700 – 10890 MHz 490 MHz

01010208002 B5-Hi 11200 – 11390 MHz

01010208003 B6-Lo 10855 – 11045 MHz

01010208004 B6-Hi 11355 – 11545 MHz

01010208005 B7-Lo 11010 – 11200 MHz

01010208006 B7-Hi 11510 – 11700 MHz

01010208007 ETSI B1-Lo 10675 – 10855 MHz 530 MHz

01010208008 B1-Hi 11205 – 11385 MHz

01010208009 B2-Lo 10795 – 10975 MHz

01010208010 B2-Hi 11325 – 11505 MHz

Page 162: Cambium network ptp 810 series 01 00 user guide

Ordering components Chapter 2: Planning considerations

2-60 phn-2779_001v000 (Jul 2012)

Cambium part number

Standard Sub-band Sub-band frequency T/R spacing

01010208011 B3-Lo 10915 – 11135 MHz

01010208012 B3-Hi 11455 – 11665 MHz

01010208013 B4-Lo 11035 – 11215 MHz

01010208014 B4-Hi 11565 – 11745 MHz

Table 44 ODUs: 13 GHz ODU-A

Cambium part number

Standard Sub-band

Sub-band frequency T/R spacing

01010583001 ETSI B1-Lo 12751 – 12814 MHz 266 MHz

01010583002 B1-Hi 13017 – 13080 MHz

01010583003 B2-Lo 12807 – 12870 MHz

01010583004 B2-Hi 13073 – 13136 MHz

01010583005 B3-Lo 12863 – 12926 MHz

01010583006 B3-Hi 13129 – 13192 MHz

01010583007 B4-Lo 12919 – 12982 MHz

01010583008 B4-Hi 13185 – 13248 MHz

Table 45 ODUs: 15 GHz ODU-A

Cambium part number

Standard Sub-band

Sub-band frequency T/R spacing

01010584001 ETSI B4-Lo 14501 – 14613 MHz 420 MHz

01010584002 B4-Hi 14921 – 15033 MHz

01010584003 B5-Lo 14606 – 14725 MHz

01010584004 B5-Hi 15026 – 15145 MHz

01010584005 B6-Lo 14718 – 14837 MHz

01010584006 B6-Hi 15138 – 15257 MHz

01010584007 B7-Lo 14816 – 14928 MHz

01010584008 B7-Hi 15236 – 15348 MHz

01010584009 ETSI B4-Lo 14403 – 14522 MHz 490 MHz

Page 163: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Ordering components

phn-2779_001v000 (Jul 2012) 2-61

Cambium part number

Standard Sub-band

Sub-band frequency T/R spacing

01010584010 B4-Hi 14893 – 15012 MHz

01010584011 B5-Lo 14515 – 14634 MHz

01010584012 B5-Hi 15005 – 15124 MHz

01010584013 B6-Lo 14627 – 14746 MHz

01010584014 B6-Hi 15117 – 15236 MHz

01010584015 B7-Lo 14739 – 14858 MHz

01010584016 B7-Hi 15229 – 15348 MHz

01010584020 ETSI B2-Lo 14500 – 14625 MHz 728 MHz

01010584021 B2-Hi 15228 – 15353 MHz

01010584022 Italy B1-Lo 14627 – 14746 MHz 315 MHz

01010584023 B1-Hi 14942 – 15061 MHz

01010584024 B2-Lo 14725 – 14844 MHz

01010584025 B2-Hi 15040 – 15159 MHz

01010584026 B3-Lo 14823 – 14942 MHz

01010584027 B3-Hi 15138 – 15257 MHz

01010584028 ETSI B1-Lo 14400 – 14512 MHz 644 MHz

01010584029 B1-Hi 15044 – 15156 MHz

01010584030 B2-Lo 14498 – 14610 MHz

01010584031 B2-Hi 15142 – 15254 MHz

01010584032 B3-Lo 14596 – 14708 MHz

01010584033 B3-Hi 15240 – 15352 MHz

Table 46 ODUs: 18 GHz ODU-B

Cambium part number

Standard Sub-band

Sub-band frequency T/R spacing

85009318001 FCC B3-Lo 17700 – 18140 MHz 1560 MHz

85009318002 B3-Hi 19260 – 19700 MHz

Page 164: Cambium network ptp 810 series 01 00 user guide

Ordering components Chapter 2: Planning considerations

2-62 phn-2779_001v000 (Jul 2012)

Table 47 ODUs: 18 GHz ODU-A

Cambium part number

Standard Sub-band

Sub-band frequency T/R spacing

01010209001 ETSI B1-Lo 17685 – 17985 MHz 1010 MHz

01010209002 B1-Hi 18695 – 18995 MHz

01010209003 B2-Lo 17930 – 18230 MHz

01010209004 B2-Hi 18940 – 19240 MHz

01010209005 B3-Lo 18180 – 18480 MHz

01010209006 B3-Hi 19190 – 19490 MHz

01010209007 B4-Lo 18400 – 18700 MHz

01010209008 B4-Hi 19410 – 19710 MHz

01010209013 FCC B3-Lo 17700 – 18140 MHz 1560 MHz

01010209014 B3-Hi 19260 – 19700 MHz

Table 48 ODUs: 23 GHz ODU-B

Cambium part number

Standard Sub-band

Sub-band frequency T/R spacing

85009319001 FCC B5-Lo 21200 – 21600 MHz 1200 MHz

85009319002 B5-Hi 22400 – 22800 MHz

85009319003 B6-Lo 21600 – 22000 MHz

85009319004 B6-Hi 22800 – 23200 MHz

85009319005 B7-Lo 22000 – 22400 MHz

85009319006 B7-Hi 23200 – 23600 MHz

Table 49 ODUs: 23 GHz ODU-A

Cambium part number

Standard Sub-band

Sub-band frequency T/R spacing

01010210001 ETSI B1-Lo 21994 – 22330 MHz 1008 MHz

01010210002 B1-Hi 23002 – 23338 MHz

01010210003 B2-Lo 22274 – 22610 MHz

01010210004 B2-Hi 23282 – 23618 MHz

Page 165: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Ordering components

phn-2779_001v000 (Jul 2012) 2-63

Cambium part number

Standard Sub-band

Sub-band frequency T/R spacing

01010210005 FCC B5-Lo 21200 – 21600 MHz 1200 MHz

01010210006 B5-Hi 22400 – 22800 MHz

01010210007 B6-Lo 21600 – 22000 MHz

01010210008 B6-Hi 22800 – 23200 MHz

01010210009 B7-Lo 22000 – 22400 MHz

01010210010 B7-Hi 23200 – 23600 MHz

01010210011 ETSI B1-Lo 21200 – 21500 MHz 1232 MHz

01010210012 B1-Hi 22432 – 22732 MHz

01010210013 B2-Lo 21472 – 21786 MHz

01010210014 B2-Hi 22704 – 23018 MHz

01010210015 B3-Lo 21779 – 22093 MHz

01010210016 B3-Hi 23011 – 23325 MHz

01010210017 B4-Lo 22086 – 22386 MHz

01010210018 B4-Hi 23318 – 23618 MHz

Table 50 ODUs: 26 GHz ODU-A

Cambium part number

Standard Sub-band

Sub-band frequency T/R spacing

01010403003 ETSI B1-Lo 24549 – 24885 MHz 1008 MHz

01010403004 B1-Hi 25557 – 25893 MHz

01010403005 B2-Lo 24829 – 25165 MHz

01010403006 B2-Hi 25837 – 26173 MHz

01010403007 B3-Lo 25109 – 25445 MHz

01010403008 B3-Hi 26117 – 26453 MHz

01010403001 FCC B1-Lo 24250 – 24450 MHz 800 MHz

01010403002 B1-Hi 25050 – 25250 MHz

Page 166: Cambium network ptp 810 series 01 00 user guide

Ordering components Chapter 2: Planning considerations

2-64 phn-2779_001v000 (Jul 2012)

Table 51 ODUs: 28 GHz ODU-A

Cambium part number

Standard Sub-band

Sub-band frequency T/R spacing

01009420001 ETSI B1-Lo 27520 – 28025 MHz 1008 MHz

01009420002 B1-Hi 28528 – 29033 MHz

01009420003 B2-Lo 27968 – 28473 MHz

01009420004 B2-Hi 28976 – 29481 MHz

Table 52 ODUs: 32 GHz ODU-A

Cambium part number

Standard Sub-band

Sub-band frequency T/R spacing

01010612001 ETSI B1-Lo 31815 – 32207 MHz 812 MHz

01010612002 B1-Hi 32627 – 33019 MHz

01010612003 B2-Lo 32179 – 32571 MHz

01010612004 B2-Hi 32991 – 33383 MHz

Table 53 ODUs: 38 GHz ODU-A

Cambium part number

Standard Sub-band

Sub-band frequency T/R spacing

01010433002 FCC B1-Lo 38595 – 38805 MHz 700 MHz

01010433003 B1-Hi 39295 – 39505 MHz

01010433004 B2-Lo 38795 – 39005 MHz

01010433005 B2-Hi 39495 – 39705 MHz

01010433006 B3-Lo 38995 – 39205 MHz

01010433007 B3-Hi 39695 – 39905 MHz

01010433008 B4-Lo 39195 – 39405 MHz

01010433009 B4-Hi 39895 – 40105 MHz

01010433010 ETSI B1-Lo 37044 – 37632 MHz 1260 MHz

01010433011 B1-Hi 38304 – 38892 MHz

01010433012 B2-Lo 37604 – 38192 MHz

01010433001 B2-Hi 38864 – 39452 MHz

Page 167: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Ordering components

phn-2779_001v000 (Jul 2012) 2-65

Ordering IF cable, grounding and LPUs

For ODU based installations, select cable and LPU components from Table 54.

Table 54 Cable and LPU components

Item Cambium part number and notes

CNT-400 coaxial cable, 50 Ω (IF cable)

CNT-400 cable is supplied by Cambium with the following lengths and part numbers.

‘50 Ohm Braided Coaxial Cable - 75 meter’. Cambium part number 30010194001.

‘50 Ohm Braided Coaxial Cable - 500 meter’. Cambium part number 30010195001.

For 1+1 and 2+0 links, order enough IF cable to connect two ODU/modem pairs at each link end.

Lightning protection unit (LPU) end kit

Quantity per link:

1+0 links: 2 LPU kits (4 LPUs).

1+1 Hot Standby links: 4 LPU kits (8 LPUs).

2+0 links: 4 LPU kits (8 LPUs).

‘LPU END KIT PTP800’. Cambium part number WB3657.

Page 168: Cambium network ptp 810 series 01 00 user guide

Ordering components Chapter 2: Planning considerations

2-66 phn-2779_001v000 (Jul 2012)

Item Cambium part number and notes

Hoisting Grip for CNT-400 cable

For hoisting the IF cable up to the ODU without damaging the connector.

Quantity per link:

1+0 links: 2 minimum.

1+1 Hot Standby links: 4 minimum.

2+0 links: 4 minimum.

‘Hoisting Grip for CNT-400 cable’. Cambium part number 07009304001.

Coaxial cable installation assembly kit (for CNT-400 cable)

Quantity per link:

1+0 links: 2 kits.

1+1 Hot Standby links: 4 kits.

2+0 links: 4 kits.

‘Coaxial Cable Installation Assembly Kit’. Cambium part number WB3616.

For kit contents, see Table 55.

Cable grounding kits for 1/4" and 3/8" cable

Additional grounding kits may be required to cover all IF cable grounding points.

‘Cable Grounding Kits For 1/4" And 3/8" Cable’. Cambium part number 01010419001.

Kit contents: grounding cable, self-amalgamating tape, PVC tape, tie-wraps, bolts, washers and nuts.

Page 169: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Ordering components

phn-2779_001v000 (Jul 2012) 2-67

Item Cambium part number and notes

Crimp tool for N-type and TNC connectors

Required for crimping N-type connectors and TNC connectors to IF cables.

‘Crimp tool for N-type connector’. Cambium part number 66010063001.

N-Type to TNC Adapter Cambium part number N000081L007.

TNC connectors Required for connecting IF cables to MMUs. Quantity per link:

1+0 links: two connectors.

2+0 links: four connectors.

Select either straight or right-angle as required.

‘TNC Male for CNT-400 braided cable’. Cambium part number N000081L005A.

‘TNC Male Right Angle for CNT-400 braided cable’. Cambium part number N000081L006A.

Use the crimp tool, Cambium part number 66010063001.

Page 170: Cambium network ptp 810 series 01 00 user guide

Ordering components Chapter 2: Planning considerations

2-68 phn-2779_001v000 (Jul 2012)

Table 55 Inventory of the coaxial cable installation assembly kit (WB3616)

Item Notes

Braided cable assembly

Quantity per kit: 1.

0.7 meter long cable to go between the ODU and the top LPU.

Cable grounding kits for 1/4" and 3/8" cable

Quantity per kit: 2.

Each kit contains, earth wire, PVC tape, self amalgamating tape and fixings.

Ground lead

Quantity per kit: 1

Green, 0.8 meter long with M5 lugs fitted each end.

Use for grounding the ODU to the top LPU.

Page 171: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Ordering components

phn-2779_001v000 (Jul 2012) 2-69

Item Notes

Ground lead

Quantity per kit: 2.

Green, 0.6 meter long with M5 lugs fitted one end and M10 the other.

Use for grounding the top and bottom LPUs to the supporting structure.

Weather proofing kit

Quantity per kit: 1.

Kit contains 6 reels of self amalgamating tape, 2 reels of 19mm wide PVC tape and 1 reel of 50mm wide PVC tape.

N type connector

Quantity per kit: 4.

To fit CNT-400 cable. Use crimp tool part number 66010063001.

Cable ties

Quantity per kit: 50.

Page 172: Cambium network ptp 810 series 01 00 user guide

Ordering components Chapter 2: Planning considerations

2-70 phn-2779_001v000 (Jul 2012)

Ordering RMKs and waveguides

For remote mounted ODUs (or couplers) select RMKs, waveguides and accessories from Table 56.

Table 56 RMKs, waveguides and accessories

Item Cambium part number and notes

ODU remote mounting kit

Quantity per remote mounted ODU: 1.

Part numbers: listed in Table 57.

Flexible waveguide

Quantity per remote mounted ODU: 1.

Part numbers: listed in Table 58.

All waveguides are 900 mm (35 in) long.

For more information, see Flexible waveguide specifications on page 4-9.

Flex-twist hanger kit

Quantity per remote mounted ODU: 2.

Part numbers: listed in Table 59.

To provide adequate support for a 900mm flexible waveguide, two hangers are required.

Page 173: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Ordering components

phn-2779_001v000 (Jul 2012) 2-71

Item Cambium part number and notes

Tapered transition

Required only for 11 GHz remote-mounted antennas, fitted between the antenna and the flexible waveguide.

Quantity per remote mounted ODU: 1.

Part number: 58010077001.

For more information, see Flexible waveguide specifications on page 4-9.

Table 57 Remote mounting kits

Band Output Cambium part number

6 GHZ UDR70 07010109008

7 GHz UBR84 07010109001

8 GHz UBR84 07010109002

11 – 13 GHZ UBR120 07010109003

15 GHz UBR140 07010109004

18 – 26 GHz UBR220 07010109005

28 – 32 GHz UBR320 07010109006

38 GHz UBR320 07010109007

Table 58 Flexible waveguides

Band Cambium part number

Atten- uation

VSWR Flanges (RMK/ antenna)

Max twist

Min bend radius (E/H plane)

6 GHz 58010076016 0.3 dB/m 1.10 PDR70 CPR137G

214°/m E: 102 mm (4.0 in) H: 204 mm (8.0 in)

Page 174: Cambium network ptp 810 series 01 00 user guide

Ordering components Chapter 2: Planning considerations

2-72 phn-2779_001v000 (Jul 2012)

Band Cambium part number

Atten- uation

VSWR Flanges (RMK/ antenna)

Max twist

Min bend radius (E/H plane)

6 GHz 58010076017 0.3 dB/m 1.10 PDR70 UDR70

214°/m E: 102 mm (4.0 in) H: 204 mm (8.0 in)

7 GHz 8 GHz

58010076019 0.4 dB/m 1.10 PBR84 UDR84

264°/m E: 76 mm (3.0 in) H: 152 mm (6.0 in)

11 GHz 13 GHz

58010076005 0.6 dB/m 1.10 PBR120 UBR120

360°/m E: 64 mm (2.5 in) H: 115 mm (4.5 in)

11 GHz 13 GHz

58010076018 0.43 dB/m 1.10 PDR100 CPR90G

310°/m E: 64 mm (2.5 in)

H: 127 mm (5 in)

15 GHz 58010076008 0.99 dB/m 1.10 PBR140 UBR140

445°/m E: 52 mm (2 in) H: 102 mm (4 in)

18 GHz 23 GHz 26 GHz

58010076011 2.6 dB/m 1.25 PBR220 UBR220

510°/m E: 38 mm (1.5 in) H: 76 mm (3.0 in)

28 GHz 32 GHz 38 GHz

58010076014 3.3 dB/m 1.30 PBR320 UBR320

510°/m E: 38 mm (1.5 in) H: 76 mm (3.0 in)

Page 175: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Ordering components

phn-2779_001v000 (Jul 2012) 2-73

Table 59 Flex-twist hanger kits available from Cambium

Accessory Frequency variant

Cambium part number

WR137 flex-twist hanger kit 6 GHz 07010118001

WR112 flex-twist hanger kit 7 – 8 GHz 07010118002

WR90 flex-twist hanger kit 11 – 13 GHz (*)

WR75 flex-twist hanger kit 11 – 13 GHz 07010118003

WR62 flex-twist hanger kit 15 GHz 07010118004

WR42 flex-twist hanger kit 18 – 26 GHz 07010118005

WR28 flex-twist hanger kit 28 – 38 GHz 07010118006

(*) Not yet available from Cambium. Order from CommScope, part number 244106A-100.

Ordering coupler mounting kits

Determine the number of coupler mounting kits required per link, as follows:

• 1+0 links: not required.

• 1+1 Hot Standby links without antenna protection: 2 coupler mounting kits.

• 1+1 Hot Standby links with antenna protection: not required.

• 2+0 co-polar links: 2 symmetric coupler mounting kits.

• 2+0 cross-polar links: not required.

Select symmetric or asymmetric couplers.

Select coupler mounting kits from Table 60.

Table 60 ODU coupler mounting kits

Band Coupler type Cambium part number

6 GHz 3 dB symmetric 07010110021

6 GHz 6 dB asymmetric 07010110022

7 GHz 3 dB symmetric 07010110001

7 GHz 6 dB asymmetric 07010110002

8 GHz 3 dB symmetric 07010110003

Page 176: Cambium network ptp 810 series 01 00 user guide

Ordering components Chapter 2: Planning considerations

2-74 phn-2779_001v000 (Jul 2012)

Band Coupler type Cambium part number

8 GHz 6 dB asymmetric 07010110004

11 GHz 3 dB symmetric 07010110005

11 GHz 6 dB asymmetric 07010110006

13 GHz 3 dB symmetric 07010110007

13 GHz 6 dB asymmetric 07010110008

15 GHz 3 dB symmetric 07010110009

15 GHz 6 dB asymmetric 07010110010

18 GHz 3 dB symmetric 07010110011

18 GHz 6 dB asymmetric 07010110012

23 GHz 3 dB symmetric 07010110013

23 GHz 6 dB asymmetric 07010110014

26 GHz 3 dB symmetric 07010110015

26 GHz 6 dB asymmetric 07010110016

28 GHz 3 dB symmetric 07010110023

28 GHz 6 dB asymmetric 07010110024

32 GHz 3 dB symmetric 07010110017

32 GHz 6 dB asymmetric 07010110018

38 GHz 3 dB symmetric 07010110019

38 GHz 6 dB asymmetric 07010110020

Page 177: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Ordering components

phn-2779_001v000 (Jul 2012) 2-75

Ordering OMKs

To upgrade any standard antenna to support a direct mount interface in a 2+0 cross-polar or 2+0 XPIC link, purchase an orthogonal mount kit (OMK). Select an OMK that is in the same band as the antenna that it is upgrading; for example, use a 6 GHz OMK to upgrade a 6 GHz antenna. Select OMKs from Table 61.

Table 61 Orthogonal mounting kits (OMKs)

Band Cambium part number

6 GHz 85009316001

7 GHz and 8 GHz 85009316002

11 GHz 85009316004

13 GHz 85009316005

15 GHz 85009316006

18 GHz 85009316007

23 GHz 85009316008

Cambium also supply dual-polar direct mount antennas complete with orthogonal mode transducers for 2+0 cross-polar links. See Ordering antennas on page 2-44.

Ordering network connection components

Select network connection components from Table 62 (copper interfaces) or Table 63 (fiber interfaces).

Table 62 Copper network cables and connectors

Item Cambium part number and notes

Screened Cat5e cable To minimise radiated emissions, use screened Cat5e cable for all copper connections from the MMU Ethernet ports (Data or Management) to any network switch.

RJ45 connectors Two required per Cat5e cable.

Page 178: Cambium network ptp 810 series 01 00 user guide

Ordering components Chapter 2: Planning considerations

2-76 phn-2779_001v000 (Jul 2012)

Table 63 Fiber network cables and connectors

Item Cambium part number and notes

Fiber cable and connectors If a fiber interface between the MMU and Ethernet switch is required, then fiber cable and connectors are needed (not supplied by Cambium).

SFP Gig-E fiber pluggable module

If a fiber interface between the MMU and Ethernet switch is required, then two SFP modules are needed.

Either: ‘SFP SX Gig-E Optical Pluggable Module - 850 nm’. Cambium part number 01010430001.

Or: ‘SFP LX Gig-E Optical Pluggable Module - 1310 nm’. Cambium part number 01010431001.

Page 179: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide

phn-2779_001v000 (Jul 2012) 3-1

Chapter 3: Legal information

This chapter provides legal notices including software license agreements.

Changes or modifications must not be made to the equipment without the express consent of the party responsible for compliance. Any such modifications could void the user’s authority to operate the equipment and will void the manufacturer’s warranty.

The following topics are described in this section:

• Cambium Networks end user license agreement on page 3-2

• Limit of liability on page 3-9

Page 180: Cambium network ptp 810 series 01 00 user guide

Cambium Networks end user license agreement Chapter 3: Legal information

3-2 phn-2779_001v000 (Jul 2012)

Cambium Networks end user license agreement

Acceptance of this agreement

In connection with Cambium’s delivery of certain proprietary software or products containing embedded or pre-loaded proprietary software, or both, Cambium is willing to license this certain proprietary software and the accompanying documentation to you only on the condition that you accept all the terms in this End User License Agreement (“Agreement”).

IF YOU DO NOT AGREE TO THE TERMS OF THIS AGREEMENT, DO NOT USE THE PRODUCT OR INSTALL THE SOFTWARE. INSTEAD, YOU MAY, FOR A FULL REFUND, RETURN THIS PRODUCT TO THE LOCATION WHERE YOU ACQUIRED IT OR PROVIDE WRITTEN VERIFICATION OF DELETION OF ALL COPIES OF THE SOFTWARE. ANY USE OF THE SOFTWARE, INCLUDING BUT NOT LIMITED TO USE ON THE PRODUCT, WILL CONSTITUTE YOUR ACCEPTANCE TO THE TERMS OF THIS AGREEMENT.

Definitions

In this Agreement, the word “Software” refers to the set of instructions for computers, in executable form and in any media, (which may include diskette, CD-ROM, downloadable internet, hardware, or firmware) licensed to you. The word “Documentation” refers to electronic or printed manuals and accompanying instructional aids licensed to you. The word “Product” refers to Cambium’s fixed wireless broadband devices for which the Software and Documentation is licensed for use.

Grant of license

Cambium Networks Limited (“Cambium”) grants you (“Licensee” or “you”) a personal, nonexclusive, non-transferable license to use the Software and Documentation subject to the Conditions of Use set forth in “Conditions of use” and the terms and conditions of this Agreement. Any terms or conditions relating to the Software and Documentation appearing on the face or reverse side of any purchase order, purchase order acknowledgment or other order document that are different from, or in addition to, the terms of this Agreement will not be binding on the parties, even if payment is accepted.

Page 181: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Cambium Networks end user license agreement

phn-2779_001v000 (Jul 2012) 3-3

Conditions of use

Any use of the Software and Documentation outside of the conditions set forth in this Agreement is strictly prohibited and will be deemed a breach of this Agreement.

1. Only you, your employees or agents may use the Software and Documentation. You will take all necessary steps to insure that your employees and agents abide by the terms of this Agreement.

2. You will use the Software and Documentation (i) only for your internal business purposes; (ii) only as described in the Software and Documentation; and (iii) in strict accordance with this Agreement.

3. You may use the Software and Documentation, provided that the use is in conformance with the terms set forth in this Agreement.

4. Portions of the Software and Documentation are protected by United States copyright laws, international treaty provisions, and other applicable laws. Therefore, you must treat the Software like any other copyrighted material (for example, a book or musical recording) except that you may either: (i) make 1 copy of the transportable part of the Software (which typically is supplied on diskette, CD-ROM, or downloadable internet), solely for back-up purposes; or (ii) copy the transportable part of the Software to a PC hard disk, provided you keep the original solely for back-up purposes. If the Documentation is in printed form, it may not be copied. If the Documentation is in electronic form, you may print out 1 copy, which then may not be copied. With regard to the copy made for backup or archival purposes, you agree to reproduce any Cambium copyright notice, and other proprietary legends appearing thereon. Such copyright notice(s) may appear in any of several forms, including machine-readable form, and you agree to reproduce such notice in each form in which it appears, to the extent it is physically possible to do so. Unauthorized duplication of the Software or Documentation constitutes copyright infringement, and in the United States is punishable in federal court by fine and imprisonment.

5. You will not transfer, directly or indirectly, any product, technical data or software to any country for which the United States Government requires an export license or other governmental approval without first obtaining such license or approval.

Page 182: Cambium network ptp 810 series 01 00 user guide

Cambium Networks end user license agreement Chapter 3: Legal information

3-4 phn-2779_001v000 (Jul 2012)

Title and restrictions

If you transfer possession of any copy of the Software and Documentation to another party outside of the terms of this agreement, your license is automatically terminated. Title and copyrights to the Software and Documentation and any copies made by you remain with Cambium and its licensors. You will not, and will not permit others to: (i) modify, translate, decompile, bootleg, reverse engineer, disassemble, or extract the inner workings of the Software or Documentation, (ii) copy the look-and-feel or functionality of the Software or Documentation; (iii) remove any proprietary notices, marks, labels, or logos from the Software or Documentation; (iv) rent or transfer all or some of the Software or Documentation to any other party without Cambium’s prior written consent; or (v) utilize any computer software or hardware which is designed to defeat any copy protection device, should the Software and Documentation be equipped with such a protection device. If the Software and Documentation is provided on multiple types of media (such as diskette, CD-ROM, downloadable internet), then you will only use the medium which best meets your specific needs, and will not loan, rent, lease, or transfer the other media contained in the package without Cambium’s written consent. Unauthorized copying of the Software or Documentation, or failure to comply with any of the provisions of this Agreement, will result in automatic termination of this license.

Confidentiality

You acknowledge that all Software and Documentation contain valuable proprietary information and trade secrets and that unauthorized or improper use of the Software and Documentation will result in irreparable harm to Cambium for which monetary damages would be inadequate and for which Cambium will be entitled to immediate injunctive relief. If applicable, you will limit access to the Software and Documentation to those of your employees and agents who need to use the Software and Documentation for your internal business purposes, and you will take appropriate action with those employees and agents to preserve the confidentiality of the Software and Documentation, using the same degree of care to avoid unauthorized or improper disclosure as you use for the protection of your own proprietary software, but in no event less than reasonable care.

You have no obligation to preserve the confidentiality of any proprietary information that: (i) was in the public domain at the time of disclosure; (ii) entered the public domain through no fault of yours; (iii) was given to you free of any obligation to keep it confidential; (iv) is independently developed by you; or (v) is disclosed as required by law provided that you notify Cambium prior to such disclosure and provide Cambium with a reasonable opportunity to respond.

Page 183: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Cambium Networks end user license agreement

phn-2779_001v000 (Jul 2012) 3-5

Right to use Cambium’s name

Except as required in “Conditions of use”, you will not, during the term of this Agreement or thereafter, use any trademark of Cambium Networks, or any word or symbol likely to be confused with any Cambium Networks trademark, either alone or in any combination with another word or words.

Transfer

The Software and Documentation may not be transferred to another party without the express written consent of Cambium, regardless of whether or not such transfer is accomplished by physical or electronic means. Cambium’s consent may be withheld at its discretion and may be conditioned upon transferee paying all applicable license fees and agreeing to be bound by this Agreement.

Updates

During the first 12 months after purchase of a Product, or during the term of any executed Maintenance and Support Agreement for the Product, you are entitled to receive Updates. An “Update” means any code in any form which is a bug fix, patch, error correction, or minor enhancement, but excludes any major feature added to the Software. Updates are available for download at the support website.

Major features may be available from time to time for an additional license fee. If Cambium makes available to you major features and no other end user license agreement is provided, then the terms of this Agreement will apply.

Maintenance

Except as provided above, Cambium is not responsible for maintenance or field service of the Software under this Agreement.

Page 184: Cambium network ptp 810 series 01 00 user guide

Cambium Networks end user license agreement Chapter 3: Legal information

3-6 phn-2779_001v000 (Jul 2012)

Disclaimer

CAMBIUM DISCLAIMS ALL WARRANTIES OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR IN ANY COMMUNICATION WITH YOU. CAMBIUM SPECIFICALLY DISCLAIMS ANY WARRANTY INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILTY, NONINFRINGEMENT, OR FITNESS FOR A PARTICULAR PURPOSE. THE SOFTWARE AND DOCUMENTATION ARE PROVIDED “AS IS.” CAMBIUM DOES NOT WARRANT THAT THE SOFTWARE WILL MEET YOUR REQUIREMENTS, OR THAT THE OPERATION OF THE SOFTWARE WILL BE UNINTERRUPTED OR ERROR FREE, OR THAT DEFECTS IN THE SOFTWARE WILL BE CORRECTED. CAMBIUM MAKES NO WARRANTY WITH RESPECT TO THE CORRECTNESS, ACCURACY, OR RELIABILITY OF THE SOFTWARE AND DOCUMENTATION. Some jurisdictions do not allow the exclusion of implied warranties, so the above exclusion may not apply to you.

Limitation of liability

THE TOTAL LIABILITY OF CAMBIUM UNDER THIS AGREEMENT FOR DAMAGES WILL NOT EXCEED THE TOTAL AMOUNT PAID BY YOU FOR THE PRODUCT LICENSED UNDER THIS AGREEMENT. IN NO EVENT WILL CAMBIUM BE LIABLE IN ANY WAY FOR INCIDENTAL, CONSEQUENTIAL, INDIRECT, SPECIAL OR PUNITIVE DAMAGES OF ANY NATURE, INCLUDING WITHOUT LIMITATION, LOST BUSINESS PROFITS, OR LIABILITY OR INJURY TO THIRD PERSONS, WHETHER FORESEEABLE OR NOT, REGARDLESS OF WHETHER CAMBIUM HAS BEEN ADVISED OF THE POSSIBLITY OF SUCH DAMAGES. Some jurisdictions do not permit limitations of liability for incidental or consequential damages, so the above exclusions may not apply to you.

Page 185: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Cambium Networks end user license agreement

phn-2779_001v000 (Jul 2012) 3-7

U.S. government

If you are acquiring the Product on behalf of any unit or agency of the U.S. Government, the following applies. Use, duplication, or disclosure of the Software and Documentation is subject to the restrictions set forth in subparagraphs (c) (1) and (2) of the Commercial Computer Software – Restricted Rights clause at FAR 52.227-19 (JUNE 1987), if applicable, unless being provided to the Department of Defense. If being provided to the Department of Defense, use, duplication, or disclosure of the Products is subject to the restricted rights set forth in subparagraph (c) (1) (ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.227-7013 (OCT 1988), if applicable. Software and Documentation may or may not include a Restricted Rights notice, or other notice referring specifically to the terms and conditions of this Agreement. The terms and conditions of this Agreement will each continue to apply, but only to the extent that such terms and conditions are not inconsistent with the rights provided to you under the aforementioned provisions of the FAR and DFARS, as applicable to the particular procuring agency and procurement transaction.

Term of license

Your right to use the Software will continue in perpetuity unless terminated as follows. Your right to use the Software will terminate immediately without notice upon a breach of this Agreement by you. Within 30 days after termination of this Agreement, you will certify to Cambium in writing that through your best efforts, and to the best of your knowledge, the original and all copies, in whole or in part, in any form, of the Software and all related material and Documentation, have been destroyed, except that, with prior written consent from Cambium, you may retain one copy for archival or backup purposes. You may not sublicense, assign or transfer the license or the Product, except as expressly provided in this Agreement. Any attempt to otherwise sublicense, assign or transfer any of the rights, duties or obligations hereunder is null and void.

Governing law

This Agreement is governed by the laws of the United States of America to the extent that they apply and otherwise by the laws of the State of Illinois.

Page 186: Cambium network ptp 810 series 01 00 user guide

Cambium Networks end user license agreement Chapter 3: Legal information

3-8 phn-2779_001v000 (Jul 2012)

Assignment

This agreement may not be assigned by you without Cambium’s prior written consent.

Survival of provisions

The parties agree that where the context of any provision indicates an intent that it survives the term of this Agreement, then it will survive.

Entire agreement

This agreement contains the parties’ entire agreement regarding your use of the Software and may be amended only in writing signed by both parties, except that Cambium may modify this Agreement as necessary to comply with applicable laws.

Third party software

The software may contain one or more items of Third-Party Software supplied by other third-party suppliers. The terms of this Agreement govern your use of any Third-Party Software UNLESS A SEPARATE THIRD-PARTY SOFTWARE LICENSE IS INCLUDED, IN WHICH CASE YOUR USE OF THE THIRD-PARTY SOFTWARE WILL THEN BE GOVERNED BY THE SEPARATE THIRD-PARTY LICENSE.

Licenses and attributions

The document PTP 810 Third Party Licenses and Attributions contains licenses and attributions for third party software components that are incorporated into the PTP 810 product. This document is available for download from the support website (see Contacting Cambium Networks on page 2).

To gain access to source code licensed under the GPL, please contact Cambium via the support web site (see Contacting Cambium Networks on page 2).

Page 187: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Limit of liability

phn-2779_001v000 (Jul 2012) 3-9

Limit of liability

IN NO EVENT SHALL CAMBIUM NETWORKS BE LIABLE TO YOU OR ANY OTHER PARTY FOR ANY DIRECT, INDIRECT, GENERAL, SPECIAL, INCIDENTAL, CONSEQUENTIAL, EXEMPLARY OR OTHER DAMAGE ARISING OUT OF THE USE OR INABILITY TO USE THE PRODUCT (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR ANY OTHER PECUNIARY LOSS, OR FROM ANY BREACH OF WARRANTY, EVEN IF CAMBIUM HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. (Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion or limitation may not apply to you.) IN NO CASE SHALL CAMBIUM’S LIABILITY EXCEED THE AMOUNT YOU PAID FOR THE PRODUCT.

Page 188: Cambium network ptp 810 series 01 00 user guide

Limit of liability Chapter 3: Legal information

3-10 phn-2779_001v000 (Jul 2012)

Page 189: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide

phn-2779_001v000 (Jul 2012) 4-1

Chapter 4: Reference information

This chapter describes the physical, environmental, safety, wireless and electromagnetic specifications for PTP 810.

The following topics are described in this chapter:

• Equipment specifications on page 4-2 contains specifications of the MMU, ODU and other equipment supplied by Cambium for PTP 810 installations. It also specifies the MMU front panel connectors.

• Wireless specifications on page 4-23 contains specifications of the PTP 810 wireless interface, including RF bands, channel width and link loss.

• Data network specifications on page 4-73 contains specifications for the PTP 810 Ethernet interfaces.

• Network management specifications on page 4-77 lists supported SNMP objects from the standard MIB-II, IF-MIB and Bridge-MIB.

• Electromagnetic compliance on page 4-79 describes how the PTP 810 complies with the regulations that are in force in various countries, and contains notifications made to regulatory bodies for the PTP 810.

• Radiation hazard assessment on page 4-83 evaluates the radiation levels produced by the PTP 810 products against ETSI and FCC standards.

Page 190: Cambium network ptp 810 series 01 00 user guide

Equipment specifications Chapter 4: Reference information

4-2 phn-2779_001v000 (Jul 2012)

Equipment specifications

This section contains specifications of the MMU, ODU and other equipment supplied by Cambium for PTP 810 installations. It also specifies the MMU front panel connectors.

MMU specifications

The PTP 810 MMU base models conform to the specifications listed in Table 64, Table 65 and Table 66.

Table 64 MMU physical specifications

Category Specification

Dimensions Width 44.5 cm (17.5 in), Height 4.45 cm (1.75 in), Depth 23.85 cm (9.4 in)

Weight 3.12 kg (7 lbs)

Table 65 MMU environmental specifications

Category Specification

Temperature –5° C to 55° C

Humidity 95% non-condensing

Table 66 MMU electrical specifications

Category Specification

Input voltage –41 V to –60 V dc

MMU dissipation Max. 40 W (single modem) Max. 61 W (dual modem)

Page 191: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Equipment specifications

phn-2779_001v000 (Jul 2012) 4-3

The MMU and ODU power consumption figures are specified in Table 67 (1+0), Table 68 (1+1) and Table 69 (2+0). The following abbreviations are used in these tables:

• ‘Standard’ means ‘PTP810 MMU Standard, 2xFE + 16xE1/T1’.

• ‘GigE’ means ‘PTP810 MMU GigE, 4xGigE + 1xGigE SFP + 2xE1/T1’.

• ‘Standard Dual Modem’ means ‘PTP810 MMU Standard Dual Modem, 2xFE + 16xE1/T1’.

• ‘GigE Dual Modem’ means ‘PTP810 MMU GigE, Dual Modem, 4xGigE + 1xGigE SFP + 2xE1/T1’.

Table 67 Worst case power consumption for 1+0 link types

Base module (*1)

Expansion I/O module

ODU-A, 6 – 11 GHz (W)

ODU-A, 13 – 38 GHz (W)

ODU-B, 6 – 11 GHz (W)

ODU-B, 13 – 18 GHz (W)

ODU-B, 23 – 38 GHz (W)

Standard 93.9 84.9 80.9 72.9 78.9

Standard 16xE1/T1 96.3 87.3 83.3 75.3 81.3

GigE 97.5 88.5 84.5 76.5 82.5

GigE 16xE1/T1 99.9 90.9 86.9 78.9 84.9

Table 68 Worst case power consumption for 1+1 link types (*1)

Base module Expansion I/O module

ODU-A, 6 – 11 GHz (W)

ODU-A, 13 – 38 GHz (W)

ODU-B, 6 – 11 GHz (W)

ODU-B, 13 – 18 GHz (W)

ODU-B, 23 – 38 GHz (W)

Standard Dual Modem 147.5 138.5 125.5 117.5 123.5

Standard Dual Modem 16xE1/T1 151.1 142.1 129.1 121.1 127.1

GigE Dual Modem 149.5 140.5 127.5 119.5 125.5

GigE Dual Modem 16xE1/T1 153.5 144.5 131.5 123.5 129.5

(*1) ‘1+1’ includes: 1+1 Hot Standby and 1+1 Hot Standby with Spatial Diversity.

Page 192: Cambium network ptp 810 series 01 00 user guide

Equipment specifications Chapter 4: Reference information

4-4 phn-2779_001v000 (Jul 2012)

Table 69 Worst case power consumption for 2+0 link types (*1)

Base module Expansion I/O module

ODU-A, 6 – 11 GHz (W)

ODU-A, 13 – 38 GHz (W)

ODU-B, 6 – 11 GHz (W)

ODU-B, 13 – 18 GHz (W)

ODU-B, 23 – 38 GHz (W)

Standard Dual Modem 171.2 153.2 145.2 129.2 141.2

Standard Dual Modem 16xE1/T1 174.8 156.8 148.8 132.8 144.8

GigE Dual Modem 173.3 155.3 147.3 131.3 143.3

GigE Dual Modem 16xE1/T1 177.2 159.2 151.2 135.2 147.2

(*1) ‘2+0’ includes: Dual 1+0, 2+0 co-polar, 2+0 cross-polar and 2+0 XPIC.

AC to DC converter specifications

The PTP 810 AC to DC converter conforms to the specifications listed in Table 70.

Table 70 AC to DC converter specifications

Category Specification

Input range 90 to 260 V ac (wide range)

Output voltage Single output -48 V dc nominal

Maximum output power 130 W

Line frequency 47 to 63 Hz

Inrush current 60 A maximum at 230 V ac, cold start 25°C

Input current 1.7 A maximum, Io = Full Load, 230 V ac

Power conversion efficiency

80% typical

Electromagnetic compatibility

FCC Part 15, Subpart B Class A

EN55022 (CISPR 22) Class A

Safety ground leakage current

0.75 mA maximum, Io = Full Load, 240 V ac input

Hold-up time 50 ms minimum, Io = Full Load, Vin = 110 V ac

Overvoltage protection 112% to 132%, crowbar design

Overcurrent protection 110% to 150%

Page 193: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Equipment specifications

phn-2779_001v000 (Jul 2012) 4-5

Category Specification

Output power dissipation Derate linearly from 100% load at 25° C to 50% load at 70°C

Operating humidity 95% maximum

Temperature 0°C to 70°C

The AC to DC converter is only suitable for operation with MMUs fitted with a single modem and only up to an MMU temperature of 40°C.

ODU specifications

The ODU conforms to the specifications listed in Table 71 and Table 72.

Table 71 ODU physical specifications

Category ODU-A ODU-B

Dimensions Diameter 26.7 cm (10.5 in), Depth 8.9 cm (3.5 in)

Diameter 25.2 cm (9.9 in), Depth 9.2 cm (3.6 in)

Weight 4.6 kg (10.1 lbs) 3.9 kg (8.6 lbs)

Table 72 ODU-A and ODU-B environmental specifications

Category Specification

Temperature –33°C to 55°C (cold start at -45°C)

Humidity 100% condensing

Waterproof IP67

UV Exposure 10 year operational life (UL746C test evidence)

Page 194: Cambium network ptp 810 series 01 00 user guide

Equipment specifications Chapter 4: Reference information

4-6 phn-2779_001v000 (Jul 2012)

RSSI output

Table 73 specifies the voltage measured at the RSSI connector of the ODU for each combination of received signal level (dBm) and channel separation or bandwidth (MHz). This table applies to ODU-A and ODU-B.

Table 73 RSSI voltage, received signal level and bandwidth

RSL (dBm)

Channel separation 7, 13.75, 14, 27.5, 28, 29.65, 55, 56, 60 or 80 MHz

Bandwidth 10, 20 or 40 MHz

Bandwidth 30 MHz

Bandwidth 50 MHz

-20 4.54 4.63 4.71 4.57

-21 4.48 4.57 4.65 4.51

-22 4.41 4.50 4.58 4.44

-23 4.35 4.44 4.52 4.38

-24 4.29 4.38 4.46 4.32

-25 4.22 4.31 4.39 4.25

-26 4.16 4.25 4.33 4.19

-27 4.10 4.19 4.27 4.13

-28 4.03 4.12 4.20 4.06

-29 3.97 4.06 4.14 4.00

-30 3.90 4.00 4.08 3.94

-31 3.84 3.93 4.01 3.87

-32 3.78 3.87 3.95 3.81

-33 3.71 3.81 3.89 3.75

-34 3.65 3.74 3.82 3.68

-35 3.59 3.68 3.76 3.62

-36 3.52 3.62 3.70 3.56

-37 3.46 3.55 3.63 3.49

-38 3.40 3.49 3.57 3.43

-39 3.33 3.43 3.51 3.37

-40 3.27 3.36 3.44 3.30

-41 3.21 3.30 3.38 3.24

-42 3.14 3.24 3.32 3.18

Page 195: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Equipment specifications

phn-2779_001v000 (Jul 2012) 4-7

RSL (dBm)

Channel separation 7, 13.75, 14, 27.5, 28, 29.65, 55, 56, 60 or 80 MHz

Bandwidth 10, 20 or 40 MHz

Bandwidth 30 MHz

Bandwidth 50 MHz

-43 3.08 3.17 3.25 3.11

-44 3.02 3.11 3.19 3.05

-45 2.95 3.05 3.13 2.98

-46 2.89 2.98 3.06 2.92

-47 2.83 2.92 3.00 2.86

-48 2.76 2.86 2.94 2.79

-49 2.70 2.79 2.87 2.73

-50 2.64 2.73 2.81 2.67

-51 2.57 2.67 2.75 2.60

-52 2.51 2.60 2.68 2.54

-53 2.45 2.54 2.62 2.48

-54 2.38 2.48 2.55 2.41

-55 2.32 2.41 2.49 2.35

-56 2.26 2.35 2.43 2.29

-57 2.19 2.29 2.36 2.22

-58 2.13 2.22 2.30 2.16

-59 2.07 2.16 2.24 2.10

-60 2.00 2.10 2.17 2.03

-61 1.94 2.03 2.11 1.97

-62 1.88 1.97 2.05 1.91

-63 1.81 1.90 1.98 1.84

-64 1.75 1.84 1.92 1.78

-65 1.69 1.78 1.86 1.72

-66 1.62 1.71 1.79 1.65

-67 1.56 1.65 1.73 1.59

-68 1.50 1.59 1.67 1.53

-69 1.43 1.52 1.60 1.46

-70 1.37 1.46 1.54 1.40

Page 196: Cambium network ptp 810 series 01 00 user guide

Equipment specifications Chapter 4: Reference information

4-8 phn-2779_001v000 (Jul 2012)

RSL (dBm)

Channel separation 7, 13.75, 14, 27.5, 28, 29.65, 55, 56, 60 or 80 MHz

Bandwidth 10, 20 or 40 MHz

Bandwidth 30 MHz

Bandwidth 50 MHz

-71 1.31 1.40 1.48 1.34

-72 1.24 1.33 1.41 1.27

-73 1.18 1.27 1.35 1.21

-74 1.11 1.21 1.29 1.15

-75 1.05 1.14 1.22 1.08

-76 0.99 1.08 1.16 1.02

-77 0.92 1.02 1.10 0.96

-78 0.86 0.95 1.03 0.89

-79 0.80 0.89 0.97 0.83

-80 0.73 0.83 0.91 0.77

-81 0.67 0.76 0.84 0.70

-82 0.61 0.70 0.78 0.64

-83 0.54 0.64 0.72 0.58

-84 0.48 0.57 0.65 0.51

-85 0.42 0.51 0.59 0.45

-86 0.35 0.45 0.53 0.39

-87 0.29 0.38 0.46 0.32

-88 0.23 0.32 0.40 0.26

-89 0.16 0.26 0.34 0.19

-90 0.10 0.19 0.27 0.13

Page 197: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Equipment specifications

phn-2779_001v000 (Jul 2012) 4-9

Flexible waveguide specifications

Waveguide flanges

Figure 54 shows the locations of the flanges on the antenna, transition, waveguide and remote mounting kit (RMK). The numbers (1 to 4) refer to Table 74.

11 GHz antennas with a CPR90G interface need a different flexible waveguide and have the tapered transition next to the RMK not the antenna.

Figure 54 Locations of waveguide flanges

The numbered call-outs in Figure 54 are:

1. Antenna flange

2. Tapered transition flanges

3. Flexible waveguide flanges

4. RMK flange

Page 198: Cambium network ptp 810 series 01 00 user guide

Equipment specifications Chapter 4: Reference information

4-10 phn-2779_001v000 (Jul 2012)

Flanges for each frequency variant

Table 74 specifies the antenna, transition, waveguide and RMK flanges for each frequency variant.

Table 74 Antenna, transition, waveguide and RMK flanges

Frequency

1 Antenna flange

2 Tapered transition flanges

3 Waveguide flange (antenna)

3 Waveguide flange (ODU)

4 RMK flange

Wave guide size

6 GHz (*) PDR70 n/a UDR70 PDR70 UDR70 WR137

6 GHz (*) CPR137G n/a CPR137G PDR70 UDR70 WR137

7 GHz PDR84 n/a UDR84 PBR84 UBR84 WR112

8 GHz PDR84 n/a UDR84 PBR84 UBR84 WR112

11 GHz PDR100 UDR100/ PBR120

UBR120 PBR120 UBR120 WR75

11 GHz CPR90G UDR100/ PBR120

CPR90G PDR100 UBR120 WR90

13 GHz PBR120 n/a UBR120 PBR120 UBR120 WR75

15 GHz PBR140 n/a UBR140 PBR140 UBR140 WR62

18 GHz PBR220 n/a UBR220 PBR220 UBR220 WR42

23 GHz PBR220 n/a UBR220 PBR220 UBR220 WR42

26 GHz PBR220 n/a UBR220 PBR220 UBR220 WR42

32 GHz PBR320 n/a UBR320 PBR320 UBR320 WR28

38 GHz PBR320 n/a UBR320 PBR320 UBR320 WR28

(*) These flanges are used for both Lower 6 GHz and Upper 6 GHz.

Page 199: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Equipment specifications

phn-2779_001v000 (Jul 2012) 4-11

Waveguide flange diagrams

Waveguide flanges are illustrated in Figure 55 (Lower and Upper 6 GHz), Figure 56 (7 to 15 GHz), Figure 57 (18 to 38 GHz) and Figure 58 (11 GHz tapered transition).

Figure 55 Waveguide flanges – 6 GHz

PDR70 UDR70

49.3

PDR70 CPR137G

49.3

6 GHz

Antenna Side Flange

RMK Side Flange

6 GHz

Note that the CPR137G has the same overall dimensions as the PDR70 but with a

shallower groove depth.

Page 200: Cambium network ptp 810 series 01 00 user guide

Equipment specifications Chapter 4: Reference information

4-12 phn-2779_001v000 (Jul 2012)

Figure 56 Waveguide flanges – 7 to 15 GHz

Page 201: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Equipment specifications

phn-2779_001v000 (Jul 2012) 4-13

Figure 57 Waveguide flanges – 18 to 38 GHz

Figure 58 Waveguide flanges – 11 GHz tapered transition

Page 202: Cambium network ptp 810 series 01 00 user guide

Equipment specifications Chapter 4: Reference information

4-14 phn-2779_001v000 (Jul 2012)

Torque values for waveguide flanges

To obtain the correct torque values for fastening waveguides, refer to Table 75.

Table 75 Torque value in Nm (lb ft) for each fastener size

Material M3 M4 M5 M6 M8

Stainless steel

0.9 (0.6)

2.2 (1.6)

4.5 (3.3)

7.7 (5.7)

18.7 (13.8)

Coupler mounting kit specifications

The ODU coupler mounting kits conform to the specifications listed in Table 76 and Table 77.

Table 76 ODU coupler physical specifications

Category Specification

Packed dimensions

250 x 280 x 390 (W x L x H) mm

10 x 11 x 15.5 (W x L x H) ins

Weight 6 GHz band:

7 GHz to 11 GHz bands: 4.6 kg (10.1 lbs)

13 GHz to 38 GHz bands: 4.2 kg (9.3 lbs)

Table 77 ODU coupler environmental specifications

Category Specification

Temperature –40°C to 50°C

Relative humidity 0% to 100%

Weatherproofing IP67

Exposure Salt mist, industrial atmospheres and UV radiation

Shock and Vibration ETSI EN 300 019-2-4 (class 4.1E) IEC class 4M5

Page 203: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Equipment specifications

phn-2779_001v000 (Jul 2012) 4-15

Coupler losses and isolation

Table 78 contains ODU port return losses and isolation figures for Cambium-supplied ODU couplers. These figures apply to both symmetric and asymmetric couplers.

Table 78 ODU coupler return losses and isolation

Bands ODU port return loss Isolation between ODU ports

6 GHz 18 dB minimum 20 dB minimum

7 GHz to 38 GHz 20 dB maximum 20 dB minimum

Table 79 contains ODU port insertion losses for Cambium-supplied ODU couplers.

Table 79 ODU coupler insertion losses

Bands Coupler type ODU port maximum insertion losses

6 GHz 3 dB symmetric

6 dB asymmetric Main 1.9 dB, Standby 6.5 dB

7 GHz to 26 GHz 3 dB symmetric 3.8 dB

6 dB asymmetric Main 1.8 dB, Standby 7.2 dB

32 GHz to 38 GHz 3 dB symmetric 4.0 dB

6 dB asymmetric Main 2.0 dB, Standby 7.4 dB

Page 204: Cambium network ptp 810 series 01 00 user guide

Equipment specifications Chapter 4: Reference information

4-16 phn-2779_001v000 (Jul 2012)

MMU front panel connectors

This section contains specifications for the PTP 810 MMU front panel connectors.

Table 80 DC Input (power) connector (Power Supply module)

Interface Pin Type Signal

MSTB 2,5/ 2-GF

1 POWER Power supply return

2 POWER -48 V dc nominal

Table 81 Ethernet 100Base-T payload connector 1-2 (Master I/O module)

Interface Pin Type Signal

RJ-45 female

1 INPUT RX+ 2 INPUT RX- 3 OUTPUT TX+ 4 N/A N/A 5 N/A N/A 6 OUTPUT TX- 7 N/A N/A 8 N/A N/A

Page 205: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Equipment specifications

phn-2779_001v000 (Jul 2012) 4-17

Table 82 Ethernet 1000Base-T payload connector 1-4 (GigE Master I/O module)

Interface Pin Type Signal

RJ-45 female

1 I/O DB+ 2 I/O DB- 3 I/O DC+ 4 I/O DA- 5 I/O DA+ 6 I/O DC- 7 I/O DD+ 8 I/O DD-

Table 83 Gigabit Ethernet optical SFP connector (GigE Master I/O module)

Interface Pin Type Signal

LC Duplex Fiber

TX OUTPUT 1000Base-SX/LX/ZX payload output (optical)

RX INPUT 1000Base-SX/LX/ZX payload input (optical)

Table 84 NMS 10/100Base-TX connector 1-2 (Control module)

Interface Pin Type Signal

RJ-45 female

1 OUTPUT TX+

2 OUTPUT TX-

3 INPUT RX+

4 N/A N/A

5 N/A N/A

6 INPUT RX-

7 N/A N/A

8 N/A N/A

Page 206: Cambium network ptp 810 series 01 00 user guide

Equipment specifications Chapter 4: Reference information

4-18 phn-2779_001v000 (Jul 2012)

Table 85 Serial/Alarm port connector (Control module)

Interface Pin Type Signal

DB-15HD female

1 OUTPUT TTL Alarm Output 3

2 INPUT/OUTPUT RS-232 RX/TX

3 OUTPUT/INPUT RS-232 TX/RX

4 OUTPUT TTL Alarm Output 4

5 N/A GROUND

6 N/A Alarm 1 Form C Contact Normally Open

7 N/A Alarm 1 Form C Contact Normally Closed

8 N/A Alarm 2 Form C Contact Common

9 INPUT TTL Alarm Input 1

10 INPUT TTL Alarm Input 3

11 N/A Alarm 1 Form C Contact Common

12 N/A Alarm 2 Form C Contact Normally Open

13 N/A Alarm 2 Form C Contact Normally Closed

14 INPUT TTL Alarm Input 2

15 INPUT TTL Alarm Input 4

Table 86 E1/T1 - channels 1-2 connector (Master I/O module)

Interface Pin Type Signal

RJ-48 female 100 Ω/120 Ω balanced

1 INPUT RX+

2 INPUT RX-

3 N/A GND

4 OUTPUT TX+

5 OUTPUT TX-

6 N/A GND

7 N/A N/A

8 N/A N/A

The interface used for the E1/T1 - Channels 3-16 (Table 87) is the Molex LFH Matrix 50 Receptacle 100 Ω /120 Ω Balanced connector (Figure 59).

Page 207: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Equipment specifications

phn-2779_001v000 (Jul 2012) 4-19

Figure 59 Molex LFH Matrix 50 Receptacle 100 Ω /120 Ω Balanced interface

Table 87 E1/T1 - channels 3-16 connector (Master I/O module)

Pin Type Signal

1 OUTPUT T1 Channel 13 Transmit Tip

2 OUTPUT T1 Channel 14 Transmit Tip

3 OUTPUT T1 Channel 15 Transmit Tip

4 OUTPUT T1 Channel 16 Transmit Tip

5 OUTPUT T1 Channel 9 Transmit Tip

6 OUTPUT T1 Channel 10 Transmit Tip

7 OUTPUT T1 Channel 11 Transmit Tip

8 OUTPUT T1 Channel 12 Transmit Tip

9 OUTPUT T1 Channel 5 Transmit Tip

10 OUTPUT T1 Channel 6 Transmit Tip

11 OUTPUT T1 Channel 7 Transmit Tip

12 OUTPUT T1 Channel 8 Transmit Tip

13 OUTPUT T1 Channel 3 Transmit Tip

14 OUTPUT T1 Channel 4 Transmit Tip

15 NC NC 16 NC NC 17 OUTPUT T1 Channel 4 Transmit Ring

18 OUTPUT T1 Channel 3 Transmit Ring

19 OUTPUT T1 Channel 8 Transmit Ring

20 OUTPUT T1 Channel 7 Transmit Ring

21 OUTPUT T1 Channel 6 Transmit Ring

22 OUTPUT T1 Channel 5 Transmit Ring

23 OUTPUT T1 Channel 12 Transmit Ring

24 OUTPUT T1 Channel 11 Transmit Ring

25 OUTPUT T1 Channel 10 Transmit Ring

26 OUTPUT T1 Channel 9 Transmit Ring

27 OUTPUT T1 Channel 16 Transmit Ring

28 OUTPUT T1 Channel 15 Transmit Ring

Page 208: Cambium network ptp 810 series 01 00 user guide

Equipment specifications Chapter 4: Reference information

4-20 phn-2779_001v000 (Jul 2012)

Pin Type Signal

29 OUTPUT T1 Channel 14 Transmit Ring

30 OUTPUT T1 Channel 13 Transmit Ring

31 INPUT T1 Channel 16 Receive Tip

32 INPUT T1 Channel 15 Receive Tip

33 INPUT T1 Channel 9 Receive Tip

34 INPUT T1 Channel 14 Receive Tip

35 INPUT T1 Channel 10 Receive Tip

36 INPUT T1 Channel 13 Receive Tip

37 INPUT T1 Channel 11 Receive Tip

38 INPUT T1 Channel 4 Receive Tip

39 INPUT T1 Channel 12 Receive Tip

40 INPUT T1 Channel 3 Receive Tip

41 INPUT T1 Channel 5 Receive Tip

42 INPUT T1 Channel 8 Receive Tip

43 INPUT T1 Channel 6 Receive Tip

44 INPUT T1 Channel 7 Receive Tip

45 NC NC 46 NC NC 47 INPUT T1 Channel 7 Receive Ring

48 INPUT T1 Channel 6 Receive Ring

49 INPUT T1 Channel 8 Receive Ring

50 INPUT T1 Channel 5 Receive Ring

51 INPUT T1 Channel 3 Receive Ring

52 INPUT T1 Channel 12 Receive Ring

53 INPUT T1 Channel 4 Receive Ring

54 INPUT T1 Channel 11 Receive Ring

55 INPUT T1 Channel 13 Receive Ring

56 INPUT T1 Channel 10 Receive Ring

57 INPUT T1 Channel 14 Receive Ring

58 INPUT T1 Channel 9 Receive Ring

59 INPUT T1 Channel 15 Receive Ring

60 INPUT T1 Channel 16 Receive Ring

Page 209: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Equipment specifications

phn-2779_001v000 (Jul 2012) 4-21

Figure 60 Data order wire - RS-422 connector

Interface Pin Type Signal

RJ-45 female

1 OUTPUT TX Clock -

2 OUTPUT TX Clock +

3 OUTPUT TX Data -

4 INPUT RX Data -

5 INPUT RX Data +

6 OUTPUT TX Data +

7 INPUT RX Clock -

8 INPUT RX Clock +

Figure 61 Data order wire - RS-232 connector

Interface Pin Type Signal

RJ-45 female

1 N/A NC

2 N/A NC

3 N/A Signal GND

4 N/A NC

5 INPUT RX Data +

6 OUTPUT TX Data +

7 N/A NC

8 N/A NC

Figure 62 XPIC connector (Modem module)

Interface Pin Type Signal

RJ-45 female

1 OUTPUT XPIC I-

2 OUTPUT XPIC I-

3 OUTPUT XPIC Q-

4 INPUT XPIC I-

5 INPUT XPIC I-

6 OUTPUT XPIC Q-

7 INPUT XPIC Q-

8 INPUT XPIC Q-

Page 210: Cambium network ptp 810 series 01 00 user guide

Equipment specifications Chapter 4: Reference information

4-22 phn-2779_001v000 (Jul 2012)

Figure 63 ODU connector (Modem module)

Interface Pin Type Signal

TNC coaxial female

Center I/O 350 MHz TX IF / 140 MHz RX IF / -48 V dc

Shield N/A Shield / Chassis GND

Page 211: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Wireless specifications

phn-2779_001v000 (Jul 2012) 4-23

Wireless specifications

This section contains specifications of the PTP 810 wireless interface, including RF bands, channel width and link loss.

General wireless specifications

The PTP 810 conforms to the general wireless specifications listed in Table 88.

Table 88 General wireless specifications

Feature Specification

Channel separation (ETSI) 7, 13.75, 14, 27.5, 28, 29.65, 30, 40, 55, 56 or 60 MHz.

Channel bandwidth (FCC/IC) 10, 20, 30, 40, 50 or 80 MHz.

Modulation QPSK, 16QAM, 32QAM, 64QAM, 128QAM and 256QAM. Fixed or adaptive modulation.

Duplex scheme Frequency division duplex.

Capacity options Basic capacity is 10 Mbps in each link direction.

May be upgraded via software license key to one of the following capacity levels: 20, 30, 40, 50, 100, 150, 200, 300, 400 or 600 Mbps.

Latency Ultra-low latency, <130 us @ 300 Mbps with 64 bytes frame.

APC Supported in all configurations apart from XPIC.

Page 212: Cambium network ptp 810 series 01 00 user guide

Wireless specifications Chapter 4: Reference information

4-24 phn-2779_001v000 (Jul 2012)

Frequency bands and channel separation

EN 302 217 refers to the relevant ITU-R and CEPT recommendations which are appropriate for operation in ETSI regions. These are summarized in Table 89.

Table 89 ETSI band plan

Band Frequency range (GHz)

Channel separation (MHz)

T/R spacing (MHz)

ERC (CEPT/ERC)

ITU-R

Lower 6 GHz

5.925-6.425 29.65 252.04 14-01 An 1 F.383-8

Upper 6 GHz

6.425-7.100 30, 40, 60 340 14-02E F.384-10

7, 14 340 - -

7 GHz 7.125-7.9 7, 14, 28 154, 161, 168, 196, 245

02-06 Annex 1 and 3

F.385-9

8 GHz 7.725 – 8.5 7, 14, 28 119, 208, 266 - F.386-8 An 2, 3, 5

29.65 311.32 - F.386-8 An 6

11 GHz 10.7-11.7 40 490, 530 12-06E F.387-10

13 GHz 12.75-13.25 7, 14, 28 266 12-02E F.497-7

15 GHz

14.4-15.35 7, 14, 28, 56 420, 490, 644, 728

T/R 12-07 F.636-3

315 - -

18 GHz 17.7-19.7 7, 13.75, 27.5, 55

1010 12-03E F.595-9

23 GHz 21.2-23.6 7, 14, 28, 56 1008 13-02E An A F.637-3 An 3, 5

7, 14, 28, 56 1232 - F.637-3 An 1

26 GHz 24.5-26.5 7, 14, 28, 56 1008 13-02E An B F.748-4 An 1

32 GHz 31.8-33.4 7, 14, 28, 56 812 Rec 01(02) F.1520-2 An 1, 2

38 GHz 37-39.5 7, 14, 28, 56 1260 T/R 12-01 F.749-2 An 1

Page 213: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Wireless specifications

phn-2779_001v000 (Jul 2012) 4-25

FCC 101.147 defines the frequency plans for FCC. These are summarized in Table 90 (ODU platforms).

Table 90 FCC and IC band plan

Band Frequency range (GHz)

Bandwidth (MHz)

T/R spacing (MHz)

FCC/IC Reference

Lower 6 GHz

5.925-6.425 10, 30 252.04 FCC, IC -

Upper 6 GHz

6.525-6.875 10, 30 160, 170 FCC only -

11 GHz 10.7-11.7 10, 30, 40 490 FCC, IC Part 101-147 (o) 10-1-08 Edition

18 GHz 17.7-19.7 10, 20, 30, 40, 50

ODU-B: 80

1560 FCC, IC Part 101-147 (r) 10-1-08 Edition

23 GHz 21.8-23.6 10, 20, 30, 40, 50

1200 FCC, IC Part 101-147 (s) 10-1-08 Edition

26 GHz 24.25-25.25 10, 20, 40 800 FCC only Part 101-147 (s) 10-1-08 Edition

38 GHz 38.6-40 10, 50 700 FCC, IC -

Capacity license keys and frequency bands

Table 91 shows capacity license keys cross-referenced to frequency bands and regulatory agencies for PTP 810.

The purchase of a capacity license key results in the generation of both a “1+x” and a “2+0” authorization key. However, there are some capacity license key and frequency band combinations which only support the “1+x” authorization key.

Page 214: Cambium network ptp 810 series 01 00 user guide

Wireless specifications Chapter 4: Reference information

4-26 phn-2779_001v000 (Jul 2012)

Table 91 Cross-Reference of capacity license keys to frequency band

Capacity key

Cambium part number

ETSI band (GHz) FCC/IC band (GHz)

L6 U6 15 18 23 26 28 32 38

7 8 13

11 L6 U6

11 26 18 23

38

10 Mbps Default None 1+x 1+x None None None 1+x 1+x 1+x

20 Mbps WB3538 None 1+x, 2+0

1+x, 2+0

None None None 1+x 1+x 1+x

30 Mbps WB3539 None 1+x, 2+0

1+x, 2+0

None None None 1+x, 2+0

1+x, 2+0

1+x, 2+0

40 Mbps WB3540 1+x 1+x, 2+0

1+x, 2+0

None None None 1+x, 2+0

1+x, 2+0

1+x, 2+0

50 Mbps WB3541 1+x 1+x, 2+0

1+x, 2+0

None 1+x 1+x 1+x, 2+0

1+x, 2+0

1+x, 2+0

100 Mbps WB3542 1+x, 2+0

1+x, 2+0

1+x, 2+0

None 1+x, 2+0

1+x, 2+0

1+x, 2+0

1+x, 2+0

1+x, 2+0

150 Mbps WB3543 1+x, 2+0

1+x, 2+0

1+x, 2+0

1+x 1+x, 2+0

1+x, 2+0

1+x, 2+0

1+x, 2+0

1+x, 2+0

200 Mbps WB3544 2+0 1+x, 2+0

2+0 1+x 2+0 1+x, 2+0

1+x, 2+0

1+x, 2+0

1+x, 2+0

300 Mbps WB3545 2+0, XPIC

All 2+0, XPIC

2+0, XPIC

2+0, XPIC

2+0, XPIC

2+0, XPIC

All 1+x, 2+0

400 Mbps WB3546 None 2+0, XPIC

None 2+0, XPIC

XPIC 2+0, XPIC

2+0, XPIC

2+0, XPIC

2+0, XPIC

600 Mbps N000081 K001

None 2+0, XPIC

None None None None None 2+0, XPIC

2+0, XPIC

Page 215: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Wireless specifications

phn-2779_001v000 (Jul 2012) 4-27

Maximum E1/T1 circuit capacity

Table 92 shows the maximum number of E1/T1 circuits referenced to link type, modulation mode and ETSI channel spacing. Table 93 shows the maximum number of E1/T1 circuits referenced to link type, modulation mode and FCC/IC bandwidth.

The maximum number of E1/T1 circuits is dependent on the choice of Master I/O module. The values in Table 92 and Table 93 are based on the Standard Master I/O Module which supports 126 E1/T1 circuits per modem. The GigE Master I/O Module only supports 63 E1/T1 circuits per modem.

Table 92 Maximum number of E1/T1 circuits with ETSI channel separations

Link Type

Modulation mode

7 MHz 13.75

14 MHz

30, 28 27.5 29.65 MHz

40 MHz 55, 56 60 MHz

1+x 256QAM 81 110 126

1+x 128QAM 16 34 70 96 126

1+x 64QAM 14 29 59 81 123

1+x 32QAM 11 23 50 68 101

1+x 16QAM 9 18 39 53 75

1+x QPSK 4 9 19 26 39

2+0 256QAM 162 205 205

2+0 128QAM 32 68 140 192 205

2+0 64QAM 28 58 118 162 205

2+0 32QAM 22 46 100 136 202

2+0 16QAM 18 36 78 106 150

2+0 QPSK 8 18 38 52 78

XPIC 256QAM 168 205 205

XPIC 128QAM 146 198 205

XPIC 64QAM 120 168 205

Page 216: Cambium network ptp 810 series 01 00 user guide

Wireless specifications Chapter 4: Reference information

4-28 phn-2779_001v000 (Jul 2012)

Table 93 Maximum number of E1/T1 circuits with FCC and Canada bandwidths

Link Type

Modulation mode

10 MHz 20 MHz 30 MHz 40 MHz 50 MHz 80 MHz

1+x 256QAM 73 110 126 126 126

1+x 128QAM 31 63 96 126 126 126

1+x 64QAM 26 53 86 109 126 126

1+x 32QAM 21 43 68 91 114 125

1+x 16QAM 17 35 53 71 89 104

1+x QPSK 8 17 26 35 44 51

2+0 256QAM 146 205 205 205 205

2+0 128QAM 62 126 192 205 205 205

2+0 64QAM 52 106 172 205 205 205

2+0 32QAM 42 86 136 182 205 205

2+0 16QAM 34 70 106 142 178 205

2+0 QPSK 16 34 52 70 88 102

XPIC 256QAM 205 205 205 205

XPIC 128QAM 198 205 205 205

XPIC 64QAM 174 205 205 205

Page 217: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Wireless specifications

phn-2779_001v000 (Jul 2012) 4-29

Capacity, transmit power and sensitivity

This section contains tables of wireless performance for PTP 810 links. The tables specify, for each frequency band, region (FCC and ETSI), bandwidth and modulation mode, the following data:

• F/R mode: This means ‘Fixed or reference mode’. It indicates whether or not the modulation mode is available as a fixed or reference mode.

• Cap (Mbps): This means ‘Capacity’. It is the maximum user capacity applied to the TDM channels, Ethernet data ports and management ports that can be transmitted over the radio interface.

• Sens (dBm): This means ‘Sensitivity’ It is the minimum receive power which can achieve a Bit Error Rate of 1 x 10-6 as defined in EN 302 217 Annex F.

• Max tx (dBm): This means 'Maximum transmit power', the maximum transmit power that can be configured in the MMU.

• Min tx (dBm): This means 'Minimum transmit power', the minimum transmit power that can be configured in the MMU.

The tables are ordered by frequency band as follows:

• Wireless performance in the Lower 6 GHz band on page 4-30

• Wireless performance in the Upper 6 GHz band on page 4-31

• Wireless performance in the 7 GHz band on page 4-35

• Wireless performance in the 8 GHz band on page 4-36

• Wireless performance in the 11 GHz band on page 4-38

• Wireless performance in the 13 GHz band on page 4-42

• Wireless performance in the 15 GHz band on page 4-44

• Wireless performance in the 18 GHz band on page 4-46

• Wireless performance in the 23 GHz band on page 4-53

• Wireless performance in the 26 GHz band on page 4-61

• Wireless performance in the 32 GHz band on page 4-67

• Wireless performance in the 38 GHz band on page 4-69

Page 218: Cambium network ptp 810 series 01 00 user guide

Wireless specifications Chapter 4: Reference information

4-30 phn-2779_001v000 (Jul 2012)

Wireless performance in the Lower 6 GHz band

The following tables contain capacity, transmit power and sensitivity data for PTP 810 links operating in the Lower 6 GHz band. For column definitions, refer to Capacity, transmit power and sensitivity on page 4-29.

Table 94 Lower 6 GHz FCC and Canada with 10 MHz bandwidth

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

128QAM 0.86 Yes 49.2 98.3 -73.8 22 9

64QAM 0.84 Yes 41.4 82.8 -77.4 22 9

32QAM 0.83 Yes 33.9 67.8 -81.1 22 9

16QAM 0.81 Yes 27.8 55.5 -85.4 22 9

QPSK 0.81 Yes 13.8 27.6 -91.6 22 9

Table 95 Lower 6 GHz FCC and Canada with 30 MHz bandwidth

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 Yes 173.0 345.9 -64.9 22 9

128QAM 0.86 Yes 149.9 299.8 -69.8 22 9

64QAM 0.89 Yes 134.4 268.8 -71.6 22 9

32QAM 0.82 Yes 107.4 214.8 -77.5 22 9

16QAM 0.81 Yes 83.5 167.1 -80.8 22 9

QPSK 0.81 Yes 41.6 83.2 -87.0 22 9

Table 96 Lower 6 GHz FCC and Canada with 30 MHz bandwidth (XPIC)

Modulation mode

F/R mode

Cap XPIC (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 Yes 357.9 -65.2 22 9

128QAM 0.86 Yes 310.2 -70.8 22 9

64QAM 0.88 Yes 273.7 -73.8 22 9

Page 219: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Wireless specifications

phn-2779_001v000 (Jul 2012) 4-31

Table 97 Lower 6 GHz ETSI with 29.65 MHz channel separation

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 Yes 168.3 336.7 -64.7 22 14

128QAM 0.86 Yes 145.9 291.8 -69.7 24 14

64QAM 0.84 Yes 123.5 246.9 -72.9 24 14

32QAM 0.83 Yes 104.5 209.0 -77.5 28 14

16QAM 0.81 Yes 81.3 162.6 -80.8 28 14

QPSK 0.81 Yes 40.5 81.0 -87.0 30 14

Table 98 Lower 6 GHz ETSI with 29.65 MHz channel separation (XPIC)

Modulation mode

F/R mode

Cap XPIC (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 Yes 348.3 -65.2 22 14

128QAM 0.86 Yes 301.8 -70.8 24 14

64QAM 0.84 Yes 255.4 -73.8 24 14

Wireless performance in the Upper 6 GHz band

The following tables contain capacity, transmit power and sensitivity data for PTP 810 links operating in the Upper 6 GHz band. For column definitions, refer to Capacity, transmit power and sensitivity on page 4-29.

Table 99 Upper 6 GHz FCC with 10 MHz bandwidth

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

128QAM 0.86 Yes 49.2 98.3 -73.8 22 9

64QAM 0.84 Yes 41.4 82.8 -77.4 22 9

32QAM 0.83 Yes 33.9 67.8 -81.1 22 9

16QAM 0.81 Yes 27.8 55.5 -85.4 22 9

QPSK 0.81 Yes 13.8 27.6 -91.6 22 9

Page 220: Cambium network ptp 810 series 01 00 user guide

Wireless specifications Chapter 4: Reference information

4-32 phn-2779_001v000 (Jul 2012)

Table 100 Upper 6 GHz FCC with 30 MHz bandwidth

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 Yes 173.0 345.9 -64.9 22 9

128QAM 0.86 Yes 149.9 299.8 -69.8 22 9

64QAM 0.89 Yes 134.4 268.8 -71.6 22 9

32QAM 0.82 Yes 107.4 214.8 -77.5 22 9

16QAM 0.81 Yes 83.5 167.1 -80.8 22 9

QPSK 0.81 Yes 41.6 83.2 -87.0 22 9

Table 101 Upper 6 GHz FCC with 30 MHz bandwidth (XPIC)

Modulation mode

F/R mode

Cap XPIC (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 Yes 357.9 -65.2 22 9

128QAM 0.86 Yes 310.2 -70.8 22 9

64QAM 0.88 Yes 273.7 -73.8 22 9

Table 102 Upper 6 GHz ETSI with 7 MHz channel separation

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

128QAM 0.86 Yes 35.5 70.9 -75.1 24 14

64QAM 0.84 Yes 30.0 60.0 -78.5 24 14

32QAM 0.83 Yes 24.6 49.1 -82.2 26 14

16QAM 0.81 Yes 20.0 40.1 -86.4 28 14

QPSK 0.81 Yes 10.0 19.9 -92.8 30 14

Page 221: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Wireless specifications

phn-2779_001v000 (Jul 2012) 4-33

Table 103 Upper 6 GHz ETSI with 14 MHz channel separation

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

128QAM 0.86 Yes 71.9 143.8 -72.7 24 14

64QAM 0.84 Yes 60.9 121.7 -74.8 24 14

32QAM 0.83 Yes 49.8 99.6 -79.3 26 14

16QAM 0.81 Yes 40.2 80.4 -83.4 28 14

QPSK 0.81 Yes 20.0 40.1 -89.9 30 14

Table 104 Upper 6 GHz ETSI with 30 MHz channel separation

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 Yes 168.3 336.7 -64.7 22 14

128QAM 0.86 Yes 145.9 291.8 -69.7 24 14

64QAM 0.84 Yes 123.5 246.9 -72.9 24 14

32QAM 0.83 Yes 104.5 209.0 -77.5 26 14

16QAM 0.81 Yes 81.3 162.6 -80.8 28 14

QPSK 0.81 Yes 40.5 81.0 -87.0 30 14

Table 105 Upper 6 GHz ETSI with 30 MHz channel separation (XPIC)

Modulation mode

F/R mode

Cap XPIC (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 Yes 348.3 -65.2 22 14

128QAM 0.86 Yes 301.8 -70.8 24 14

64QAM 0.84 Yes 255.4 -73.8 24 14

Page 222: Cambium network ptp 810 series 01 00 user guide

Wireless specifications Chapter 4: Reference information

4-34 phn-2779_001v000 (Jul 2012)

Table 106 Upper 6 GHz ETSI with 40 MHz channel separation

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 No 230.4 460.8 - 22 14

128QAM 0.86 Yes 199.7 399.4 -68.5 24 14

64QAM 0.84 Yes 169.0 338.0 -71.6 24 14

32QAM 0.82 No 142.3 284.7 - 26 14

16QAM 0.81 No 110.7 221.4 - 28 14

QPSK 0.81 No 55.4 110.8 - 30 14

Table 107 Upper 6 GHz ETSI with 40 MHz channel separation (XPIC)

Modulation mode

F/R mode

Cap XPIC (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 No 474.4 - 22 14

128QAM 0.86 Yes 411.1 -69.4 24 14

64QAM 0.84 Yes 347.9 -72.9 24 14

Table 108 Upper 6 GHz ETSI with 60 MHz channel separation

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 Yes 339.5 679.0 -62.1 22 14

128QAM 0.86 Yes 294.2 588.5 -66.7 24 14

64QAM 0.84 Yes 255.4 510.7 -70.7 24 14

32QAM 0.82 No 208.9 417.9 - 28 14

16QAM 0.81 No 155.2 310.3 - 28 14

QPSK 0.81 No 81.3 162.6 - 30 14

Page 223: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Wireless specifications

phn-2779_001v000 (Jul 2012) 4-35

Table 109 Upper 6 GHz ETSI with 60 MHz channel separation (XPIC)

Modulation mode

F/R mode

Cap XPIC (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 Yes 696.4 -63.0 22 14

128QAM 0.86 Yes 603.6 -67.5 24 14

64QAM 0.84 Yes 510.7 -71.0 24 14

Wireless performance in the 7 GHz band

The following tables contain capacity, transmit power and sensitivity data for PTP 810 links operating in the 7 GHz band. For column definitions, refer to Capacity, transmit power and sensitivity on page 4-29.

Table 110 7 GHz ETSI with 7 MHz channel separation

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

128QAM 0.86 Yes 35.5 70.9 -75.1 24 14

64QAM 0.84 Yes 30.0 60.0 -78.5 24 14

32QAM 0.83 No 24.6 49.1 - 28 14

16QAM 0.81 Yes 20.0 40.1 -86.4 28 14

QPSK 0.81 Yes 10.0 19.9 -92.8 30 14

Table 111 7 GHz ETSI with 14 MHz channel separation

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

128QAM 0.86 Yes 71.9 143.8 -72.7 24 14

64QAM 0.84 Yes 60.9 121.7 -74.8 24 14

32QAM 0.83 Yes 49.8 99.6 -79.3 28 14

16QAM 0.81 Yes 40.2 80.4 -83.4 28 14

QPSK 0.81 Yes 20.0 40.1 -89.9 30 14

Page 224: Cambium network ptp 810 series 01 00 user guide

Wireless specifications Chapter 4: Reference information

4-36 phn-2779_001v000 (Jul 2012)

Table 112 7 GHz ETSI with 28 MHz channel separation

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 Yes 168.3 336.7 -64.7 22 14

128QAM 0.86 Yes 145.9 291.8 -69.7 24 14

64QAM 0.84 Yes 123.5 246.9 -72.9 24 14

32QAM 0.83 Yes 104.5 209.0 -77.5 28 14

16QAM 0.81 Yes 81.3 162.6 -80.8 28 14

QPSK 0.81 Yes 40.5 81.0 -87.0 30 14

Table 113 7 GHz ETSI with 28 MHz channel separation (XPIC)

Modulationmode

F/R mode

Cap XPIC (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 Yes 348.3 -65.2 22 14

128QAM 0.86 Yes 301.8 -70.8 24 14

64QAM 0.84 Yes 255.4 -73.8 24 14

Wireless performance in the 8 GHz band

The following tables contain capacity, transmit power and sensitivity data for PTP 810 links operating in the 8 GHz band. For column definitions, refer to Capacity, transmit power and sensitivity on page 4-29.

Table 114 8 GHz ETSI with 7 MHz channel separation

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

128QAM 0.86 Yes 35.5 70.9 -75.1 24 14

64QAM 0.84 Yes 30.0 60.0 -78.5 24 14

32QAM 0.83 No 24.6 49.1 - 28 14

16QAM 0.81 Yes 20.0 40.1 -86.4 28 14

QPSK 0.81 Yes 10.0 19.9 -92.8 30 14

Page 225: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Wireless specifications

phn-2779_001v000 (Jul 2012) 4-37

Table 115 8 GHz ETSI with 14 MHz channel separation

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

128QAM 0.86 Yes 71.9 143.8 -72.7 24 14

64QAM 0.84 Yes 60.9 121.7 -74.8 24 14

32QAM 0.83 Yes 49.8 99.6 -79.3 28 14

16QAM 0.81 Yes 40.2 80.4 -83.4 28 14

QPSK 0.81 Yes 20.0 40.1 -89.9 30 14

Table 116 8 GHz ETSI with 28 MHz channel separation

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 Yes 168.3 336.7 -64.7 22 14

128QAM 0.86 Yes 145.9 291.8 -69.7 24 14

64QAM 0.84 Yes 123.5 246.9 -72.9 24 14

32QAM 0.83 Yes 104.5 209.0 -77.5 28 14

16QAM 0.81 Yes 81.3 162.6 -80.8 28 14

QPSK 0.81 Yes 40.5 81.0 -87.0 30 14

Table 117 8 GHz ETSI with 28 MHz channel separation (XPIC)

Modulation mode

F/R mode

Cap XPIC (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 Yes 348.3 -65.2 22 14

128QAM 0.86 Yes 301.8 -70.8 24 14

64QAM 0.84 Yes 255.4 -73.8 24 14

Page 226: Cambium network ptp 810 series 01 00 user guide

Wireless specifications Chapter 4: Reference information

4-38 phn-2779_001v000 (Jul 2012)

Table 118 8 GHz ETSI with 29.65 MHz channel separation

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 Yes 168.3 336.7 -64.7 22 14

128QAM 0.86 Yes 145.9 291.8 -69.7 24 14

64QAM 0.84 Yes 123.5 246.9 -72.9 24 14

32QAM 0.83 Yes 104.5 209.0 -77.5 28 14

16QAM 0.81 Yes 81.3 162.6 -80.8 28 14

QPSK 0.81 Yes 40.5 81.0 -87.0 30 14

Table 119 8 GHz ETSI with 29.65 MHz channel separation (XPIC)

Modulation mode

F/R mode

Cap XPIC (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 Yes 348.3 -65.2 22 14

128QAM 0.86 Yes 301.8 -70.8 24 14

64QAM 0.84 Yes 255.4 -73.8 24 14

Wireless performance in the 11 GHz band

The following tables contain capacity, transmit power and sensitivity data for PTP 810 links operating in the 11 GHz band. For column definitions, refer to Capacity, transmit power and sensitivity on page 4-29.

Table 120 11 GHz FCC and Canada with 10 MHz bandwidth (ODU-A)

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

128QAM 0.86 Yes 49.2 98.3 -74.3 19 6

64QAM 0.84 Yes 41.4 82.8 -77.9 19 6

32QAM 0.83 Yes 33.9 67.8 -81.6 19 6

16QAM 0.81 Yes 27.8 55.5 -85.9 19 6

QPSK 0.81 Yes 13.8 27.6 -92.1 19 6

Page 227: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Wireless specifications

phn-2779_001v000 (Jul 2012) 4-39

Table 121 11 GHz FCC and Canada with 10 MHz bandwidth (ODU-B)

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

128QAM 0.86 Yes 49.2 98.3 -74.3 20 5

64QAM 0.84 Yes 41.4 82.8 -77.9 20 5

32QAM 0.83 Yes 33.9 67.8 -81.6 20 5

16QAM 0.81 Yes 27.8 55.5 -85.9 20 5

QPSK 0.81 Yes 13.8 27.6 -92.1 20 5

Table 122 11 GHz FCC and Canada with 30 MHz bandwidth (ODU-A)

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 Yes 173.0 345.9 -65.4 19 6

128QAM 0.86 Yes 149.9 299.8 -70.3 19 6

64QAM 0.89 Yes 134.4 268.8 -72.1 19 6

32QAM 0.82 Yes 107.4 214.8 -78.0 19 6

16QAM 0.81 Yes 83.5 167.1 -80.1 19 6

QPSK 0.81 Yes 41.6 83.2 -87.5 19 6

Table 123 11 GHz FCC and Canada with 30 MHz bandwidth (ODU-B)

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 Yes 173.0 345.9 -65.4 20 5

128QAM 0.86 Yes 149.9 299.8 -70.3 20 5

64QAM 0.89 Yes 134.4 268.8 -72.1 20 5

32QAM 0.82 Yes 107.4 214.8 -78.0 20 5

16QAM 0.81 Yes 83.5 167.1 -80.1 20 5

QPSK 0.81 Yes 41.6 83.2 -87.5 20 5

Page 228: Cambium network ptp 810 series 01 00 user guide

Wireless specifications Chapter 4: Reference information

4-40 phn-2779_001v000 (Jul 2012)

Table 124 11 GHz FCC and Canada with 30 MHz bandwidth (XPIC) (ODU-A)

Modulation mode

F/R mode

Cap XPIC (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 Yes 357.9 -65.8 19 6

128QAM 0.86 Yes 310.2 -71.4 19 6

64QAM 0.88 Yes 273.7 -74.0 19 6

Table 125 11 GHz FCC and Canada with 30 MHz bandwidth (XPIC) (ODU-B)

Modulation mode

F/R mode

Cap XPIC (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 Yes 357.9 -65.8 20 5

128QAM 0.86 Yes 310.2 -71.4 20 5

64QAM 0.88 Yes 273.7 -74.0 20 5

Table 126 11 GHz FCC and Canada with 40 MHz bandwidth (ODU-A)

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 Yes 231.7 463.5 -64.7 19 6

128QAM 0.86 Yes 200.8 401.7 -68.9 19 6

64QAM 0.84 Yes 170.0 339.9 -72.0 19 6

32QAM 0.83 Yes 143.2 286.3 -76.7 19 6

16QAM 0.81 Yes 111.4 222.7 -80.1 19 6

QPSK 0.81 Yes 55.7 111.4 -86.3 19 6

Page 229: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Wireless specifications

phn-2779_001v000 (Jul 2012) 4-41

Table 127 11 GHz FCC and Canada with 40 MHz bandwidth (ODU-B)

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 Yes 231.7 463.5 -64.7 20 5

128QAM 0.86 Yes 200.8 401.7 -68.9 20 5

64QAM 0.84 Yes 170.0 339.9 -72.0 20 5

32QAM 0.83 Yes 143.2 286.3 -76.7 20 5

16QAM 0.81 Yes 111.4 222.7 -80.1 20 5

QPSK 0.81 Yes 55.7 111.4 -86.3 20 5

Table 128 11 GHz FCC and Canada with 40 MHz bandwidth (XPIC) (ODU-A)

Modulation mode

F/R mode

Cap XPIC (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 Yes 477.1 -65.1 19 6

128QAM 0.86 Yes 413.5 -69.9 19 6

64QAM 0.84 Yes 349.9 -73.3 19 6

Table 129 11 GHz FCC and Canada with 40 MHz bandwidth (XPIC) (ODU-B)

Modulation mode

F/R mode

Cap XPIC (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 Yes 477.1 -65.1 20 5

128QAM 0.86 Yes 413.5 -69.9 20 5

64QAM 0.84 Yes 349.9 -73.3 20 5

Page 230: Cambium network ptp 810 series 01 00 user guide

Wireless specifications Chapter 4: Reference information

4-42 phn-2779_001v000 (Jul 2012)

Table 130 11 GHz ETSI with 40 MHz channel separation

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 No 230.4 460.8 - 19 11

128QAM 0.86 Yes 199.7 399.4 -69.0 21 11

64QAM 0.84 Yes 169.0 338.0 -72.1 21 11

32QAM 0.82 No 142.3 284.7 - 26 11

16QAM 0.81 No 110.7 221.4 - 26 11

QPSK 0.81 No 55.4 110.8 - 28 11

Table 131 11 GHz ETSI with 40 MHz channel separation (XPIC)

Modulation mode

F/R mode

Cap XPIC (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 No 474.4 - 19 11

128QAM 0.86 Yes 411.1 -69.9 21 11

64QAM 0.84 Yes 347.9 -73.4 21 11

Wireless performance in the 13 GHz band

The following tables contain capacity, transmit power and sensitivity data for PTP 810 links operating in the 13 GHz band. For column definitions, refer to Capacity, transmit power and sensitivity on page 4-29.

Table 132 13 GHz ETSI with 7 MHz channel separation

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

128QAM 0.86 Yes 35.5 70.9 -75.6 18 8

64QAM 0.84 Yes 30.0 60.0 -79.0 18 8

32QAM 0.83 No 24.6 49.1 - 23 8

16QAM 0.81 Yes 20.0 40.1 -86.9 23 8

QPSK 0.81 Yes 10.0 19.9 -93.3 26 8

Page 231: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Wireless specifications

phn-2779_001v000 (Jul 2012) 4-43

Table 133 13 GHz ETSI with 14 MHz channel separation

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

128QAM 0.86 Yes 71.9 143.8 -73.2 18 8

64QAM 0.84 Yes 60.9 121.7 -75.3 18 8

32QAM 0.83 Yes 49.8 99.6 -79.8 23 8

16QAM 0.81 Yes 40.2 80.4 -83.9 23 8

QPSK 0.81 Yes 20.0 40.1 -90.4 26 8

Table 134 13 GHz ETSI with 28 MHz channel separation

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 Yes 168.3 336.7 -65.2 16 8

128QAM 0.86 Yes 145.9 291.8 -70.2 18 8

64QAM 0.84 Yes 123.5 246.9 -73.4 18 8

32QAM 0.83 Yes 104.5 209.0 -78.0 23 8

16QAM 0.81 Yes 81.3 162.6 -81.3 23 8

QPSK 0.81 Yes 40.5 81.0 -87.5 26 8

Table 135 13 GHz ETSI with 28 MHz channel separation (XPIC)

Modulation mode

F/R mode

Cap XPIC (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 Yes 348.3 -65.7 16 8

128QAM 0.86 Yes 301.8 -71.3 18 8

64QAM 0.84 Yes 255.4 -74.3 18 8

Page 232: Cambium network ptp 810 series 01 00 user guide

Wireless specifications Chapter 4: Reference information

4-44 phn-2779_001v000 (Jul 2012)

Wireless performance in the 15 GHz band

The following tables contain capacity, transmit power and sensitivity data for PTP 810 links operating in the 15 GHz band. For column definitions, refer to Capacity, transmit power and sensitivity on page 4-29.

Table 136 15 GHz ETSI with 7 MHz channel separation

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

128QAM 0.86 Yes 35.5 70.9 -75.6 18 8

64QAM 0.84 Yes 30.0 60.0 -79.0 18 8

32QAM 0.83 No 24.6 49.1 - 23 8

16QAM 0.81 Yes 20.0 40.1 -86.9 23 8

QPSK 0.81 Yes 10.0 19.9 -93.3 26 8

Table 137 15 GHz ETSI with 14 MHz channel separation

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

128QAM 0.86 Yes 71.9 143.8 -73.2 18 8

64QAM 0.84 Yes 60.9 121.7 -75.3 18 8

32QAM 0.83 Yes 49.8 99.6 -79.8 23 8

16QAM 0.81 Yes 40.2 80.4 -83.9 23 8

QPSK 0.81 Yes 20.0 40.1 -90.4 26 8

Table 138 15 GHz ETSI with 28 MHz channel separation

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 Yes 168.3 336.7 -65.2 16 8

128QAM 0.86 Yes 145.9 291.8 -70.2 18 8

64QAM 0.84 Yes 123.5 246.9 -73.4 18 8

32QAM 0.83 Yes 104.5 209.0 -78.0 23 8

16QAM 0.81 Yes 81.3 162.6 -81.3 23 8

QPSK 0.81 Yes 40.5 81.0 -87.5 26 8

Page 233: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Wireless specifications

phn-2779_001v000 (Jul 2012) 4-45

Table 139 15 GHz ETSI with 28 MHz channel separation (XPIC)

Modulation mode

F/R mode

Cap XPIC (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 Yes 348.3 -65.7 16 8

128QAM 0.86 Yes 301.8 -71.3 18 8

64QAM 0.84 Yes 255.4 -74.3 18 8

Table 140 15 GHz ETSI with 56 MHz channel separation

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256 QAM 0.86 Yes 339.5 679.0 -62.6 16 8

128 QAM 0.86 Yes 294.2 588.5 -67.2 18 8

64 QAM 0.84 Yes 255.4 510.7 -71.2 18 8

32 QAM 0.83 No 208.9 417.9 - 23 8

16 QAM 0.81 Yes 155.2 310.3 -78.7 23 8

QPSK 0.81 Yes 81.3 162.6 -84.2 26 8

Table 141 15 GHz ETSI with 56 MHz channel separation (XPIC)

Modulation mode

F/R mode

Cap XPIC (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 Yes 696.4 -63.5 16 8

128QAM 0.86 Yes 603.6 -68.0 18 8

64QAM 0.84 Yes 510.7 -71.5 18 8

Page 234: Cambium network ptp 810 series 01 00 user guide

Wireless specifications Chapter 4: Reference information

4-46 phn-2779_001v000 (Jul 2012)

Wireless performance in the 18 GHz band

The following tables contain capacity, transmit power and sensitivity data for PTP 810 links operating in the 18 GHz band. For column definitions, refer to Capacity, transmit power and sensitivity on page 4-29.

Table 142 18 GHz FCC and Canada with 10 MHz bandwidth (ODU-A)

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

128QAM 0.86 Yes 49.2 98.3 -74.3 17 2

64QAM 0.84 Yes 41.4 82.8 -77.9 17 2

32QAM 0.83 Yes 33.9 67.8 -81.6 22 2

16QAM 0.81 Yes 27.8 55.5 -85.9 22 2

QPSK 0.81 Yes 13.8 27.6 -92.1 23 2

Table 143 18 GHz FCC and Canada with 10 MHz bandwidth (ODU-B)

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

128QAM 0.86 Yes 49.2 98.3 -74.3 19 2

64QAM 0.84 Yes 41.4 82.8 -77.9 19 2

32QAM 0.83 Yes 33.9 67.8 -81.6 23 2

16QAM 0.81 Yes 27.8 55.5 -85.9 23 2

QPSK 0.81 Yes 13.8 27.6 -92.1 24 2

Table 144 18 GHz FCC and Canada with 20 MHz bandwidth (ODU-A)

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256 QAM 0.86 Yes 114.5 229.1 -68.0 15 2

128 QAM 0.86 Yes 99.3 198.5 -72.1 17 2

64 QAM 0.84 Yes 84.0 168.0 -75.1 17 2

32 QAM 0.83 Yes 68.8 137.5 -78.6 22 2

16 QAM 0.81 Yes 55.7 111.4 -82.7 22 2

QPSK 0.81 Yes 27.8 55.5 -89.1 23 2

Page 235: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Wireless specifications

phn-2779_001v000 (Jul 2012) 4-47

Table 145 18 GHz FCC and Canada with 20 MHz bandwidth (ODU-B)

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256 QAM 0.86 Yes 114.5 229.1 -68.0 17 2

128 QAM 0.86 Yes 99.3 198.5 -72.1 19 2

64 QAM 0.84 Yes 84.0 168.0 -75.1 19 2

32 QAM 0.83 Yes 68.8 137.5 -78.6 23 2

16 QAM 0.81 Yes 55.7 111.4 -82.7 23 2

QPSK 0.81 Yes 27.8 55.5 -89.1 24 2

Table 146 18 GHz FCC and Canada with 30 MHz bandwidth (ODU-A)

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256 QAM 0.86 Yes 173.0 345.9 -65.4 15 2

128 QAM 0.86 Yes 149.9 299.8 -70.3 17 2

64 QAM 0.84 Yes 134.4 268.8 -72.1 17 2

32 QAM 0.83 Yes 107.4 214.8 -78.0 22 2

16 QAM 0.81 Yes 83.5 167.1 -80.1 22 2

QPSK 0.81 Yes 41.6 83.2 -87.5 23 2

Table 147 18 GHz FCC and Canada with 30 MHz bandwidth (ODU-B)

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256 QAM 0.86 Yes 173.0 345.9 -65.4 17 2

128 QAM 0.86 Yes 149.9 299.8 -70.3 19 2

64 QAM 0.84 Yes 134.4 268.8 -72.1 19 2

32 QAM 0.83 Yes 107.4 214.8 -78.0 23 2

16 QAM 0.81 Yes 83.5 167.1 -80.1 23 2

QPSK 0.81 Yes 41.6 83.2 -87.5 24 2

Page 236: Cambium network ptp 810 series 01 00 user guide

Wireless specifications Chapter 4: Reference information

4-48 phn-2779_001v000 (Jul 2012)

Table 148 18 GHz FCC and Canada with 30 MHz bandwidth (XPIC) (ODU-A)

Modulation mode

F/R mode

Cap XPIC (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256 QAM 0.86 Yes 357.9 -65.8 15 2

128 QAM 0.86 Yes 310.2 -71.4 17 2

64 QAM 0.84 Yes 273.7 -74.0 17 2

Table 149 18 GHz FCC and Canada with 30 MHz bandwidth (XPIC) (ODU-B)

Modulation mode

F/R mode

Cap XPIC (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256 QAM 0.86 Yes 357.9 -65.8 17 2

128 QAM 0.86 Yes 310.2 -71.4 19 2

64 QAM 0.84 Yes 273.7 -74.0 19 2

Table 150 18 GHz FCC and Canada with 40 MHz bandwidth (ODU-A)

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256 QAM 0.86 Yes 231.7 463.5 -64.7 15 2

128 QAM 0.86 Yes 200.8 401.7 -68.9 17 2

64 QAM 0.84 Yes 170.0 339.9 -72.0 17 2

32 QAM 0.83 Yes 143.2 286.3 -76.7 22 2

16 QAM 0.81 Yes 111.4 222.7 -80.1 22 2

QPSK 0.81 Yes 55.7 111.4 -86.3 23 2

Page 237: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Wireless specifications

phn-2779_001v000 (Jul 2012) 4-49

Table 151 18 GHz FCC and Canada with 40 MHz bandwidth (ODU-B)

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256 QAM 0.86 Yes 231.7 463.5 -64.7 17 2

128 QAM 0.86 Yes 200.8 401.7 -68.9 19 2

64 QAM 0.84 Yes 170.0 339.9 -72.0 19 2

32 QAM 0.83 Yes 143.2 286.3 -76.7 23 2

16 QAM 0.81 Yes 111.4 222.7 -80.1 23 2

QPSK 0.81 Yes 55.7 111.4 -86.3 24 2

Table 152 18 GHz FCC and Canada with 40 MHz bandwidth (XPIC) (ODU-A)

Modulation mode

F/R mode

Cap XPIC (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256 QAM 0.86 Yes 477.1 -64.7 15 2

128 QAM 0.86 Yes 200.8 -68.9 17 2

64 QAM 0.84 Yes 170.0 -72.0 17 2

Table 153 18 GHz FCC and Canada with 40 MHz bandwidth (XPIC) (ODU-B)

Modulation mode

F/R mode

Cap XPIC (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256 QAM 0.86 Yes 477.1 -65.1 17 2

128 QAM 0.86 Yes 413.5 -69.9 19 2

64 QAM 0.84 Yes 349.9 -73.3 19 2

Page 238: Cambium network ptp 810 series 01 00 user guide

Wireless specifications Chapter 4: Reference information

4-50 phn-2779_001v000 (Jul 2012)

Table 154 18 GHz FCC and Canada with 50 MHz bandwidth (ODU-A)

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256 QAM 0.86 Yes 290.7 581.4 -63.2 15 2

128 QAM 0.86 Yes 252.0 503.9 -68.0 17 2

64 QAM 0.84 Yes 218.7 437.3 -72.2 17 2

32 QAM 0.83 Yes 178.9 357.9 -75.7 22 2

16 QAM 0.81 Yes 139.2 278.4 -78.9 22 2

QPSK 0.81 Yes 69.6 139.2 -85.0 23 2

Table 155 18 GHz FCC and Canada with 50 MHz bandwidth (ODU-B)

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256 QAM 0.86 Yes 290.7 581.4 -63.2 17 2

128 QAM 0.86 Yes 252.0 503.9 -68.0 19 2

64 QAM 0.84 Yes 218.7 437.3 -72.2 19 2

32 QAM 0.83 Yes 178.9 357.9 -75.7 23 2

16 QAM 0.81 Yes 139.2 278.4 -78.9 23 2

QPSK 0.81 Yes 69.6 139.2 -85.0 24 2

Table 156 18 GHz FCC and Canada with 50 MHz bandwidth (XPIC) (ODU-A)

Modulation mode

F/R mode

Cap XPIC (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256 QAM 0.86 Yes 596.3 -64.4 15 2

128 QAM 0.86 Yes 516.8 -68.7 17 2

64 QAM 0.84 Yes 437.1 -72.1 17 2

Page 239: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Wireless specifications

phn-2779_001v000 (Jul 2012) 4-51

Table 157 18 GHz FCC and Canada with 50 MHz bandwidth (XPIC) (ODU-B)

Modulation mode

F/R mode

Cap XPIC (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256 QAM 0.86

Yes 596.3 -64.4 17 2

128 QAM 0.86

Yes 516.8 -68.7 19 2

64 QAM 0.84

Yes 437.1 -72.1 19 2

Table 158 18 GHz FCC and Canada with 80 MHz bandwidth (ODU-B)

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256 QAM 0.86 Yes 339.5 679.0 -62.6 17 2

128 QAM 0.86 Yes 294.2 588.5 -67.2 19 2

64 QAM 0.84 Yes 255.4 510.7 -71.2 19 2

32 QAM 0.83 Yes 208.9 417.9 -74.9 23 2

16 QAM 0.81 Yes 162.5 325.0 -77.9 23 2

QPSK 0.81 Yes 81.3 162.6 -84.2 24 2

Table 159 18 GHz FCC and Canada with 80 MHz bandwidth (XPIC) (ODU-B)

Modulation mode

F/R mode

Cap XPIC (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256 QAM 0.86 Yes 696.4 -63.5 17 2

128 QAM 0.86 Yes 603.6 -67.8 19 2

64 QAM 0.84 Yes 510.7 -71.3 19 2

Page 240: Cambium network ptp 810 series 01 00 user guide

Wireless specifications Chapter 4: Reference information

4-52 phn-2779_001v000 (Jul 2012)

Table 160 18 GHz ETSI with 7 MHz channel separation

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

128 QAM 0.86 Yes 35.5 70.9 -75.6 17 7

64 QAM 0.84 Yes 30.0 60.0 -79.0 17 7

32 QAM 0.83 No 24.6 49.1 - 22 7

16 QAM 0.81 Yes 20.0 40.1 -86.9 22 7

QPSK 0.81 Yes 10.0 19.9 -93.3 25.5 7

Table 161 18 GHz ETSI with 13.75 MHz channel separation

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

128 QAM 0.86 Yes 71.9 143.8 -73.2 17 7

64 QAM 0.84 Yes 60.9 121.7 -75.3 17 7

32 QAM 0.83 Yes 49.8 99.6 -79.8 22 7

16 QAM 0.81 Yes 40.2 80.4 -83.9 22 7

QPSK 0.81 Yes 20.0 40.1 -90.4 25.5 7

Table 162 18 GHz ETSI with 27.5 MHz channel separation

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 Yes 168.3 336.7 -65.2 15 7

128QAM 0.86 Yes 145.9 291.8 -70.2 17 7

64QAM 0.84 Yes 123.5 246.9 -73.4 17 7

32QAM 0.83 Yes 104.5 209.0 -78.0 22 7

16QAM 0.81 Yes 81.3 162.6 -81.3 22 7

QPSK 0.81 Yes 40.5 81.0 -87.5 25.5 7

Page 241: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Wireless specifications

phn-2779_001v000 (Jul 2012) 4-53

Table 163 18 GHz ETSI with 55 MHz channel separation

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256 QAM 0.86 Yes 339.5 679.0 -62.6 15 7

128 QAM 0.86 Yes 294.2 588.5 -67.2 17 7

64 QAM 0.84 Yes 255.4 510.7 -71.2 17 7

32 QAM 0.83 No 208.9 417.9 - 22 7

16 QAM 0.81 Yes 155.2 310.3 -78.7 22 7

QPSK 0.81 Yes 81.3 162.6 -84.2 25.5 7

Wireless performance in the 23 GHz band

The following tables contain capacity, transmit power and sensitivity data for PTP 810 links operating in the 23 GHz band. For column definitions, refer to Capacity, transmit power and sensitivity on page 4-29.

Table 164 23 GHz FCC and Canada with 10 MHz bandwidth (ODU-A)

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

128 QAM 0.86 Yes 49.2 98.3 -73.8 17 2

64 QAM 0.84 Yes 41.4 82.8 -77.4 17 2

32 QAM 0.83 Yes 33.9 67.8 -81.1 22 2

16 QAM 0.81 Yes 27.8 55.5 -85.4 22 2

QPSK 0.81 Yes 13.8 27.6 -91.6 23 2

Page 242: Cambium network ptp 810 series 01 00 user guide

Wireless specifications Chapter 4: Reference information

4-54 phn-2779_001v000 (Jul 2012)

Table 165 23 GHz FCC and Canada with 10 MHz bandwidth (ODU-B)

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

128 QAM 0.86 Yes 49.2 98.3 -73.8 19 2

64 QAM 0.84 Yes 41.4 82.8 -77.4 19 2

32 QAM 0.83 Yes 33.9 67.8 -81.1 23 2

16 QAM 0.81 Yes 27.8 55.5 -85.4 23 2

QPSK 0.81 Yes 13.8 27.6 -91.6 23 2

Table 166 23 GHz FCC and Canada with 20 MHz bandwidth (ODU-A)

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256 QAM 0.86 Yes 114.5 229.1 -67.5 15 2

128 QAM 0.86 Yes 99.3 198.5 -71.6 17 2

64 QAM 0.84 Yes 84.0 168.0 -74.6 17 2

32 QAM 0.83 Yes 68.8 137.5 -78.1 22 2

16 QAM 0.81 Yes 55.7 111.4 -82.2 22 2

QPSK 0.81 Yes 27.8 55.5 -88.6 23 2

Table 167 23 GHz FCC and Canada with 20 MHz bandwidth (ODU-B)

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256 QAM 0.86 Yes 114.5 229.1 -67.5 17 2

128 QAM 0.86 Yes 99.3 198.5 -71.6 19 2

64 QAM 0.84 Yes 84.0 168.0 -74.6 19 2

32 QAM 0.83 Yes 68.8 137.5 -78.1 23 2

16 QAM 0.81 Yes 55.7 111.4 -82.2 23 2

QPSK 0.81 Yes 27.8 55.5 -88.6 23 2

Page 243: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Wireless specifications

phn-2779_001v000 (Jul 2012) 4-55

Table 168 23 GHz FCC and Canada with 30 MHz bandwidth (ODU-A)

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256 QAM 0.86 Yes 173.0 345.9 -64.9 15 2

128 QAM 0.86 Yes 149.9 299.8 -69.8 17 2

64 QAM 0.84 Yes 134.4 268.8 -71.6 17 2

32 QAM 0.83 Yes 107.4 214.8 -77.5 22 2

16 QAM 0.81 Yes 83.5 167.1 -80.8 22 2

QPSK 0.81 Yes 41.6 83.2 -87.0 23 2

Table 169 23 GHz FCC and Canada with 30 MHz bandwidth (ODU-B)

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256 QAM 0.86 Yes 173.0 345.9 -64.9 17 2

128 QAM 0.86 Yes 149.9 299.8 -69.8 19 2

64 QAM 0.84 Yes 134.4 268.8 -71.6 19 2

32 QAM 0.83 Yes 107.4 214.8 -77.5 23 2

16 QAM 0.81 Yes 83.5 167.1 -80.8 23 2

QPSK 0.81 Yes 41.6 83.2 -87.0 23 2

Table 170 23 GHz FCC and Canada with 30 MHz bandwidth (XPIC) (ODU-A)

Modulation mode

F/R mode

Cap XPIC (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256 QAM 0.86 Yes 357.9 -65.3 15 2

128 QAM 0.86 Yes 310.2 -70.9 17 2

64 QAM 0.84 Yes 273.7 -73.5 17 2

Page 244: Cambium network ptp 810 series 01 00 user guide

Wireless specifications Chapter 4: Reference information

4-56 phn-2779_001v000 (Jul 2012)

Table 171 23 GHz FCC and Canada with 30 MHz bandwidth (XPIC) (ODU-B)

Modulation mode

F/R mode

Cap XPIC (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256 QAM 0.86 Yes 357.9 -65.3 17 2

128 QAM 0.86 Yes 310.2 -70.9 19 2

64 QAM 0.84 Yes 273.7 -73.5 19 2

Table 172 23 GHz FCC and Canada with 40 MHz bandwidth (ODU-A)

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256 QAM 0.86 Yes 231.7 463.5 -64.2 15 2

128 QAM 0.86 Yes 200.8 401.7 -68.4 17 2

64 QAM 0.84 Yes 170.0 339.9 -71.5 17 2

32 QAM 0.83 Yes 143.2 286.3 -76.2 22 2

16 QAM 0.81 Yes 111.4 222.7 -79.6 22 2

QPSK 0.81 Yes 55.7 111.4 -85.8 23 2

Table 173 23 GHz FCC and Canada with 40 MHz bandwidth (ODU-B)

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256 QAM 0.86 Yes 231.7 463.5 -64.2 17 2

128 QAM 0.86 Yes 200.8 401.7 -68.4 19 2

64 QAM 0.84 Yes 170.0 339.9 -71.5 19 2

32 QAM 0.83 Yes 143.2 286.3 -76.2 23 2

16 QAM 0.81 Yes 111.4 222.7 -79.6 23 2

QPSK 0.81 Yes 55.7 111.4 -85.8 23 2

Page 245: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Wireless specifications

phn-2779_001v000 (Jul 2012) 4-57

Table 174 23 GHz FCC and Canada with 40 MHz bandwidth (XPIC) (ODU-A)

Modulation mode

F/R mode

Cap XPIC (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256 QAM 0.86 Yes 477.1 -64.6 15 2

128 QAM 0.86 Yes 200.8 -69.4 17 2

64 QAM 0.84 Yes 170.0 -72.8 17 2

Table 175 23 GHz FCC and Canada with 40 MHz bandwidth (XPIC) (ODU-B)

Modulation mode

F/R mode

Cap XPIC (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256 QAM 0.86 Yes 477.1 -64.6 17 2

128 QAM 0.86 Yes 413.5 -69.4 19 2

64 QAM 0.84 Yes 349.9 -72.8 19 2

Table 176 23 GHz FCC and Canada with 50 MHz bandwidth (ODU-A)

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256 QAM 0.86 Yes 290.7 581.4 -62.7 15 2

128 QAM 0.86 Yes 252.0 503.9 -67.5 17 2

64 QAM 0.84 Yes 218.7 437.3 -71.7 17 2

32 QAM 0.83 Yes 178.9 357.9 -75.2 22 2

16 QAM 0.81 Yes 139.2 278.4 -78.4 22 2

QPSK 0.81 Yes 69.6 139.2 -84.5 23 2

Page 246: Cambium network ptp 810 series 01 00 user guide

Wireless specifications Chapter 4: Reference information

4-58 phn-2779_001v000 (Jul 2012)

Table 177 23 GHz FCC and Canada with 50 MHz bandwidth (ODU-B)

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256 QAM 0.86 Yes 290.7 581.4 -62.7 17 2

128 QAM 0.86 Yes 252.0 503.9 -67.5 19 2

64 QAM 0.84 Yes 218.7 437.3 -71.7 19 2

32 QAM 0.83 Yes 178.9 357.9 -75.2 23 2

16 QAM 0.81 Yes 139.2 278.4 -78.4 23 2

QPSK 0.81 Yes 69.6 139.2 -84.5 23 2

Table 178 23 GHz FCC and Canada with 50 MHz bandwidth (XPIC) (ODU-A)

Modulation mode

F/R mode

Cap XPIC (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256 QAM 0.86 Yes 596.3 -63.9 15 2

128 QAM 0.86 Yes 516.8 -68.2 17 2

64 QAM 0.84 Yes 437.1 -71.6 17 2

Table 179 23 GHz FCC and Canada with 50 MHz bandwidth (XPIC) (ODU-B)

Modulation mode

F/R mode

Cap XPIC (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256 QAM 0.86 Yes 596.3 -63.9 17 2

128 QAM 0.86 Yes 516.8 -68.2 19 2

64 QAM 0.84 Yes 437.1 -71.6 19 2

Page 247: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Wireless specifications

phn-2779_001v000 (Jul 2012) 4-59

Table 180 23 GHz ETSI with 7 MHz channel separation

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

128 QAM 0.86 Yes 35.5 70.9 -75.1 17 2

64 QAM 0.84 Yes 30.0 60.0 -78.5 17 2

32 QAM 0.83 No 24.6 49.1 - 22 2

16 QAM 0.81 Yes 20.0 40.1 -86.4 22 2

QPSK 0.81 Yes 10.0 19.9 -92.8 25 2

Table 181 23 GHz ETSI with 14 MHz channel separation

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

128 QAM 0.86 Yes 71.9 143.8 -72.7 17 7

64 QAM 0.84 Yes 60.9 121.7 -74.8 17 7

32 QAM 0.83 Yes 49.8 99.6 - 22 7

16 QAM 0.81 Yes 40.2 80.4 -83.4 22 7

QPSK 0.81 Yes 20.0 40.1 -89.9 25 7

Table 182 23 GHz ETSI with 28 MHz channel separation

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 Yes 168.3 336.7 -64.7 15 7

128QAM 0.86 Yes 145.9 291.8 -69.7 17 7

64QAM 0.84 Yes 123.5 246.9 -72.9 17 7

32QAM 0.83 Yes 104.5 209.0 -77.5 22 7

16QAM 0.81 Yes 81.3 162.6 -80.8 22 7

QPSK 0.81 Yes 40.5 81.0 -87.0 25 7

Page 248: Cambium network ptp 810 series 01 00 user guide

Wireless specifications Chapter 4: Reference information

4-60 phn-2779_001v000 (Jul 2012)

Table 183 23 GHz ETSI with 28 MHz channel separation (XPIC)

Modulation mode

F/R mode

Cap XPIC (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 Yes 348.3 -65.2 15 7

128QAM 0.86 Yes 301.8 -70.8 17 7

64QAM 0.84 Yes 255.4 -73.8 17 7

Table 184 23 GHz ETSI with 56 MHz channel separation

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256 QAM 0.86 Yes 339.5 679.0 -62.1 15 7

128 QAM 0.86 Yes 294.2 588.5 -66.7 17 7

64 QAM 0.84 Yes 255.4 510.7 -70.7 17 7

32 QAM 0.83 No 208.9 417.9 - 22 7

16 QAM 0.81 Yes 155.2 310.3 -78.2 22 7

QPSK 0.81 Yes 81.3 162.6 -83.7 25 7

Table 185 23 GHz ETSI with 56 MHz channel separation (XPIC)

Modulation mode

F/R mode

Cap XPIC (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 Yes 696.4 -65.2 15 7

128QAM 0.86 Yes 603.6 -70.8 17 7

64QAM 0.84 Yes 510.7 -73.8 17 7

Page 249: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Wireless specifications

phn-2779_001v000 (Jul 2012) 4-61

Wireless performance in the 26 GHz band

The following tables contain capacity, transmit power and sensitivity data for PTP 810 links operating in the 26 GHz band. For column definitions, refer to Capacity, transmit power and sensitivity on page 4-29.

Table 186 26 GHz FCC with 10 MHz bandwidth

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

128 QAM 0.86 Yes 49.2 98.3 -73.8 17 2

64 QAM 0.84 Yes 41.4 82.8 -77.4 17 2

32 QAM 0.83 Yes 33.9 67.8 -81.1 22 2

16 QAM 0.81 Yes 27.8 55.5 -85.4 22 2

QPSK 0.81 Yes 13.8 27.6 -91.6 23 2

Table 187 26 GHz FCC with 20 MHz bandwidth

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256 QAM 0.86 Yes 114.5 229.1 -67.5 15 2

128 QAM 0.86 Yes 99.3 198.5 -71.6 17 2

64 QAM 0.84 Yes 84.0 168.0 -74.6 17 2

32 QAM 0.83 Yes 68.8 137.5 -78.1 22 2

16 QAM 0.81 Yes 55.7 111.4 -82.2 22 2

QPSK 0.81 Yes 27.8 55.5 -88.6 23 2

Page 250: Cambium network ptp 810 series 01 00 user guide

Wireless specifications Chapter 4: Reference information

4-62 phn-2779_001v000 (Jul 2012)

Table 188 26 GHz FCC with 40 MHz bandwidth

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256 QAM 0.86 Yes 231.7 463.5 -64.2 15 2

128 QAM 0.86 Yes 200.8 401.7 -68.4 17 2

64 QAM 0.84 Yes 170.0 339.9 -71.5 17 2

32 QAM 0.83 Yes 143.2 286.3 -76.2 22 2

16 QAM 0.81 Yes 111.4 222.7 -79.6 22 2

QPSK 0.81 Yes 55.7 111.4 -85.8 23 2

Table 189 26 GHz FCC with 40 MHz bandwidth (XPIC)

Modulation mode

F/R mode

Cap XPIC (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256 QAM 0.86 Yes 477.1 -64.6 15 2

128 QAM 0.86 Yes 200.8 -69.4 17 2

64 QAM 0.84 Yes 170.0 -72.8 17 2

Table 190 26 GHz ETSI with 7 MHz channel separation

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

128 QAM 0.86 Yes 35.5 70.9 -75.1 17 7

64 QAM 0.84 Yes 30.0 60.0 -78.5 17 7

32 QAM 0.83 No 24.6 49.1 - 22 7

16 QAM 0.81 Yes 20.0 40.1 -86.4 22 7

QPSK 0.81 Yes 10.0 19.9 -92.8 25 7

Page 251: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Wireless specifications

phn-2779_001v000 (Jul 2012) 4-63

Table 191 26 GHz ETSI with 14 MHz channel separation

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

128 QAM 0.86 Yes 71.9 143.8 -72.7 17 7

64 QAM 0.84 Yes 60.9 121.7 -74.8 17 7

32 QAM 0.83 Yes 49.8 99.6 - 22 7

16 QAM 0.81 Yes 40.2 80.4 -83.4 22 7

QPSK 0.81 Yes 20.0 40.1 -89.9 25 7

Table 192 26 GHz ETSI with 28 MHz channel separation

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 Yes 168.3 336.7 -64.7 15 7

128QAM 0.86 Yes 145.9 291.8 -69.7 17 7

64QAM 0.84 Yes 123.5 246.9 -72.9 17 7

32QAM 0.83 Yes 104.5 209.0 -77.5 22 7

16QAM 0.81 Yes 81.3 162.6 -80.8 22 7

QPSK 0.81 Yes 40.5 81.0 -87.0 25 7

Table 193 26 GHz ETSI with 28 MHz channel separation (XPIC)

Modulation mode

F/R mode

Cap XPIC (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 Yes 348.3 -65.2 15 7

128QAM 0.86 Yes 301.8 -70.8 17 7

64QAM 0.84 Yes 255.4 -73.8 17 7

Page 252: Cambium network ptp 810 series 01 00 user guide

Wireless specifications Chapter 4: Reference information

4-64 phn-2779_001v000 (Jul 2012)

Table 194 26 GHz ETSI with 56 MHz channel separation

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256 QAM 0.86 Yes 339.5 679.0 -62.1 15 7

128 QAM 0.86 Yes 294.2 588.5 -66.7 17 7

64 QAM 0.84 Yes 255.4 510.7 -70.7 17 7

32 QAM 0.83 No 208.9 417.9 - 22 7

16 QAM 0.81 Yes 155.2 310.3 -78.2 22 7

QPSK 0.81 Yes 81.3 162.6 -83.7 25 7

Table 195 26 GHz ETSI with 56 MHz channel separation (XPIC)

Modulation mode

F/R mode

Cap XPIC (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 Yes 696.4 -65.2 15 7

128QAM 0.86 Yes 603.6 -70.8 17 7

64QAM 0.84 Yes 510.7 -73.8 17 7

Page 253: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Wireless specifications

phn-2779_001v000 (Jul 2012) 4-65

Wireless performance in the 28 GHz band

The following tables contain capacity, transmit power and sensitivity data for PTP 810 links operating in the 28 GHz band. For column definitions, refer to Capacity, transmit power and sensitivity on page 4-29.

Table 196 28 GHz ETSI with 7 MHz bandwidth

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

128 QAM 0.86 Yes 35.5 70.9 -74.6 17 7

64 QAM 0.84 Yes 30.0 60.0 -78.0 17 7

32 QAM 0.83 No 24.6 49.1 -81.7 20 7

16 QAM 0.81 Yes 20.0 40.1 -85.9 22 7

QPSK 0.81 Yes 10.0 19.9 -92.3 25 7

Table 197 28 GHz ETSI with 14 MHz channel separation

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

128 QAM 0.86 Yes 71.9 143.8 -72.2 17 7

64 QAM 0.84 Yes 60.9 121.7 -74.3 17 7

32 QAM 0.83 Yes 49.8 99.6 -78.8 20 7

16 QAM 0.81 Yes 40.2 80.4 -82.9 22 7

QPSK 0.81 Yes 20.0 40.1 -89.4 25 7

Table 198 28 GHz ETSI with 28 MHz channel separation

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 Yes 168.3 336.7 -64.2 15 7

128QAM 0.86 Yes 145.9 291.8 -69.2 17 7

64QAM 0.84 Yes 123.5 246.9 -72.4 17 7

32QAM 0.83 Yes 104.5 209.0 -77.0 20 7

16QAM 0.81 Yes 81.3 162.6 -80.3 22 7

QPSK 0.81 Yes 40.5 81.0 -86.5 25 7

Page 254: Cambium network ptp 810 series 01 00 user guide

Wireless specifications Chapter 4: Reference information

4-66 phn-2779_001v000 (Jul 2012)

Table 199 28 GHz ETSI with 28 MHz channel separation (XPIC)

Modulation mode

F/R mode

Cap XPIC (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 Yes 348.3 -64.7 15 7

128QAM 0.86 Yes 301.8 -70.3 17 7

64QAM 0.84 Yes 255.4 -73.3 17 7

Table 200 28 GHz ETSI with 56 MHz channel separation

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256 QAM 0.86 Yes 339.5 679.0 -61.6 15 7

128 QAM 0.86 Yes 294.2 588.5 -66.2 17 7

64 QAM 0.84 Yes 255.4 510.7 -70.2 17 7

32 QAM 0.83 No 208.9 417.9 -73.9 20 7

16 QAM 0.81 Yes 155.2 310.3 -77.7 22 7

QPSK 0.81 Yes 81.3 162.6 -83.2 25 7

Table 201 28 GHz ETSI with 56 MHz channel separation (XPIC)

Modulation mode

F/R mode

Cap XPIC (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 Yes 696.4 -62.5 15 7

128QAM 0.86 Yes 603.6 -67.0 17 7

64QAM 0.84 Yes 510.7 -70.5 17 7

Page 255: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Wireless specifications

phn-2779_001v000 (Jul 2012) 4-67

Wireless performance in the 32 GHz band

The following tables contain capacity, transmit power and sensitivity data for PTP 810 links operating in the 32 GHz band. For column definitions, refer to Capacity, transmit power and sensitivity on page 4-29.

Table 202 32 GHz ETSI with 7 MHz channel separation

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

128 QAM 0.86 Yes 35.5 70.9 -74.1 16 6

64 QAM 0.84 Yes 30.0 60.0 -77.5 16 6

32 QAM 0.83 No 24.6 49.1 -81.2 19 6

16 QAM 0.81 Yes 20.0 40.1 -85.4 21 6

QPSK 0.81 Yes 10.0 19.9 -91.8 23 6

Table 203 28 GHz ETSI with 14 MHz channel separation

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

128 QAM 0.86 Yes 71.9 143.8 -71.7 16 6

64 QAM 0.84 Yes 60.9 121.7 -73.8 16 6

32 QAM 0.83 Yes 49.8 99.6 -78.3 19 6

16 QAM 0.81 Yes 40.2 80.4 -82.4 21 6

QPSK 0.81 Yes 20.0 40.1 -88.9 23 6

Table 204 32 GHz ETSI with 28 MHz channel separation

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 Yes 168.3 336.7 -63.7 14 6

128QAM 0.86 Yes 145.9 291.8 -68.7 16 6

64QAM 0.84 Yes 123.5 246.9 -71.9 16 6

32QAM 0.83 Yes 104.5 209.0 -76.5 19 6

16QAM 0.81 Yes 81.3 162.6 -79.8 21 6

QPSK 0.81 Yes 40.5 81.0 -86.0 23 6

Page 256: Cambium network ptp 810 series 01 00 user guide

Wireless specifications Chapter 4: Reference information

4-68 phn-2779_001v000 (Jul 2012)

Table 205 32 GHz ETSI with 28 MHz channel separation (XPIC)

Modulation mode

F/R mode

Cap XPIC (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 Yes 348.3 -64.2 14 6

128QAM 0.86 Yes 301.8 -69.8 16 6

64QAM 0.84 Yes 255.4 -72.8 16 6

Table 206 32 GHz ETSI with 56 MHz channel separation

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256 QAM 0.86 Yes 339.5 679.0 -61.1 14 6

128 QAM 0.86 Yes 294.2 588.5 -65.7 16 6

64 QAM 0.84 Yes 255.4 510.7 -69.7 16 6

32 QAM 0.83 No 208.9 417.9 -73.4 19 6

16 QAM 0.81 Yes 155.2 310.3 -77.2 21 6

QPSK 0.81 Yes 81.3 162.6 -82.7 23 6

Table 207 32 GHz ETSI with 56 MHz channel separation (XPIC)

Modulation mode

F/R mode

Cap XPIC (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 Yes 696.4 -62.0 14 6

128QAM 0.86 Yes 603.6 -66.5 16 6

64QAM 0.84 Yes 510.7 -70.0 16 6

Page 257: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Wireless specifications

phn-2779_001v000 (Jul 2012) 4-69

Wireless performance in the 38 GHz band

The following tables contain capacity, transmit power and sensitivity data for PTP 810 links operating in the 38 GHz band. For column definitions, refer to Capacity, transmit power and sensitivity on page 4-29.

Table 208 38 GHz FCC and Canada with 10 MHz bandwidth

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

128 QAM 0.86 Yes 49.2 98.3 -70.8 16 1

64 QAM 0.84 Yes 41.4 82.8 -74.4 16 1

32 QAM 0.83 Yes 33.9 67.8 -78.1 20 1

16 QAM 0.81 Yes 27.8 55.5 -82.4 20 1

QPSK 0.81 Yes 13.8 27.6 -88.6 21 1

Table 209 38 GHz FCC and Canada with 50 MHz bandwidth

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256 QAM 0.86 Yes 290.7 581.4 -59.7 14 1

128 QAM 0.86 Yes 252.0 503.9 -64.5 16 1

64 QAM 0.84 Yes 218.7 437.3 -68.7 16 1

32 QAM 0.83 Yes 178.9 357.9 -72.2 20 1

16 QAM 0.81 Yes 139.2 278.4 -75.4 20 1

QPSK 0.81 Yes 69.6 139.2 -81.5 21 1

Page 258: Cambium network ptp 810 series 01 00 user guide

Wireless specifications Chapter 4: Reference information

4-70 phn-2779_001v000 (Jul 2012)

Table 210 38 GHz FCC and Canada with 50 MHz bandwidth (XPIC)

Modulation mode

F/R mode

Cap XPIC (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256 QAM 0.86 Yes 596.3 -60.9 14 1

128 QAM 0.86 Yes 516.8 -65.2 16 1

64 QAM 0.84 Yes 437.1 -68.6 16 1

Table 211 38 GHz ETSI with 7 MHz channel separation

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

128 QAM 0.86 Yes 35.5 70.9 -73.1 16 6

64 QAM 0.84 Yes 30.0 60.0 -76.5 16 6

32 QAM 0.83 No 24.6 49.1 - 20 6

16 QAM 0.81 Yes 20.0 40.1 -84.4 20 6

QPSK 0.81 Yes 10.0 19.9 -90.8 23 6

Table 212 38 GHz ETSI with 14 MHz channel separation

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

128 QAM 0.86 Yes 71.9 143.8 -70.7 16 6

64 QAM 0.84 Yes 60.9 121.7 -72.8 16 6

32 QAM 0.83 Yes 49.8 99.6 - 20 6

16 QAM 0.81 Yes 40.2 80.4 -81.4 20 6

QPSK 0.81 Yes 20.0 40.1 -87.9 23 6

Page 259: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Wireless specifications

phn-2779_001v000 (Jul 2012) 4-71

Table 213 38 GHz ETSI with 28 MHz channel separation

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 Yes 168.3 336.7 -62.7 14 6

128QAM 0.86 Yes 145.9 291.8 -67.7 16 6

64QAM 0.84 Yes 123.5 246.9 -70.9 16 6

32QAM 0.83 Yes 104.5 209.0 -75.5 20 6

16QAM 0.81 Yes 81.3 162.6 -78.8 20 6

QPSK 0.81 Yes 40.5 81.0 -85.0 23 6

Table 214 38 GHz ETSI with 28 MHz channel separation (XPIC)

Modulation mode

F/R mode

Cap XPIC (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 Yes 348.3 -63.2 14 6

128QAM 0.86 Yes 301.8 -68.8 16 6

64QAM 0.84 Yes 255.4 -71.8 16 6

Table 215 38 GHz ETSI with 56 MHz channel separation

Modulation mode

F/R mode

Cap 1+x (Mbps)

Cap 2+0 (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256 QAM 0.86 Yes 339.5 679.0 -60.1 14 6

128 QAM 0.86 Yes 294.2 588.5 -64.7 16 6

64 QAM 0.84 Yes 255.4 510.7 -68.7 16 6

32 QAM 0.83 No 208.9 417.9 - 20 6

16 QAM 0.81 Yes 155.2 310.3 -76.2 20 6

QPSK 0.81 Yes 81.3 162.6 -81.7 23 6

Page 260: Cambium network ptp 810 series 01 00 user guide

Wireless specifications Chapter 4: Reference information

4-72 phn-2779_001v000 (Jul 2012)

Table 216 38 GHz ETSI with 56 MHz channel separation (XPIC)

Modulation mode

F/R mode

Cap XPIC (Mbps)

Sens (dBm)

Max tx (dBm)

Min tx (dBm)

256QAM 0.86 Yes 696.4 -61.0 14 6

128QAM 0.86 Yes 603.6 -65.5 16 6

64QAM 0.84 Yes 510.7 -69.0 16 6

Page 261: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Data network specifications

phn-2779_001v000 (Jul 2012) 4-73

Data network specifications

This section contains specifications for the PTP 810 Ethernet interfaces.

Fast Ethernet specifications

The PTP 810 conforms to the Fast Ethernet specifications listed in Table 217.

Table 217 Fast Ethernet specifications

Feature Specification

Ethernet Speed 100 Base-T

Operation Full-Duplex, Half-Duplex, Auto-Negotiation

Bridging type Store and forward switching, dynamic address learning, spanning tree protocol capable.

Supports 802.1D-2004:

Section 9 Encoding of bridge protocol data units.

Section 14 Bridge Management (partial support via GUI and proprietary MIB).

Section 16 Bridge Performance.

Section 17 Rapid Spanning Tree Protocol.

MAC address capacity The MMU supports two MAC addresses. One is for NMS and the other is for payload. In addition, internal Ethernet switches can learn up to 4096 addresses.

Buffering 64 KB for Standard Master I/O module

Packet Size Min = 64 bytes

Max = 2048 bytes for Standard Master I/O module

VLAN support VLAN tagged packets may be passed through without modification. User configurable Port based and Tag based VLANs are also supported.

Page 262: Cambium network ptp 810 series 01 00 user guide

Data network specifications Chapter 4: Reference information

4-74 phn-2779_001v000 (Jul 2012)

Feature Specification

Quality of Service

(QoS)

QoS is implemented using weighted priority queues.

Incoming packets are assigned to a priority queue based on one or more of the following criteria:

-Incoming Port: port based priority allows assignment to a priority queue based upon the port the packet arrived on

-802.1Q VLAN Tag Priority: packets are assigned to a priority queue based upon the priority tag field in the VLAN TAG.

-DiffServ: packets are assigned to a priority queue based upon the value of the DS field of the IPv4 header (the DS field is the re- defined IPv4 TOS field)

Priority Queues: 4

Flow Control Flow control is supported in both full-duplex and half-duplex. Full-Duplex is implemented with respect for PAUSE packets as well as generation of PAUSE packets. Half-Duplex is implemented with back-pressure.

Page 263: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Data network specifications

phn-2779_001v000 (Jul 2012) 4-75

Gigabit Ethernet specifications

The PTP 810 conforms to the Gigabit Ethernet specifications listed in Table 218.

Table 218 Gigabit Ethernet specifications

Feature Specification

Ethernet Speed 1000 Base-T

Operation Full-Duplex, Half-Duplex, Auto-Negotiation

Bridging type Store and forward switching, dynamic address learning, spanning tree protocol capable.

Supports 802.1D-2004:

Section 9 Encoding of bridge protocol data units.

Section 14 Bridge Management (partial support via GUI and proprietary MIB).

Section 16 Bridge Performance.

Section 17 Rapid Spanning Tree Protocol.

MAC address capacity The MMU supports two MAC addresses. One is for NMS and the other is for payload. In addition, internal Ethernet switches can learn up to 1024 addresses.

Buffering 128KB for GigE Master I/O module

Packet Size Min = 64 bytes

Max = 4000 bytes for GigE Master I/O module with “S” software version.

Max = 9728 bytes for GigE Master I/O module with “J” software version.

VLAN support VLAN tagged packets may be passed through without modification. User configurable Port based and Tag based VLANs are also supported.

Page 264: Cambium network ptp 810 series 01 00 user guide

Data network specifications Chapter 4: Reference information

4-76 phn-2779_001v000 (Jul 2012)

Feature Specification

Quality of Service

(QoS)

QoS is implemented using weighted priority queues.

Incoming packets are assigned to a priority queue based on one or more of the following criteria:

Incoming Port: port based priority allows assignment to a priority queue based upon the port the packet arrived on.

802.1Q VLAN Tag Priority: packets are assigned to a priority queue based upon the priority tag field in the VLAN TAG.

DiffServ: packets are assigned to a priority queue based upon the value of the DS field of the IPv4 header (the DS field is the re-defined IPv4 TOS field).

Priority Queues: 4

Flow Control Flow control is supported in both full-duplex and half-duplex. Full-Duplex is implemented with respect for PAUSE packets as well as generation of PAUSE packets. Half-Duplex is implemented with back-pressure.

Page 265: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Network management specifications

phn-2779_001v000 (Jul 2012) 4-77

Network management specifications

This section lists supported SNMP objects from the standard MIB-II, IF-MIB and Bridge-MIB.

Standard SNMP MIBs

PTP 810 supports the following SNMP objects from the standard MIB-II, IF-MIB and Bridge-MIB:

MIBs

A Managed Information Base (MIB) file describes a type of device in a network as a data structure. The MMU SNMP agent supports the following MIBs.

• ccm_reg.mib: This MIB file contains the registration for CarrierComm enterprise OID and sub trees for CarrierComm products.

• ccm_SDIDU.mib: This is the main MIB file for the MMU product.

• ccm_SDIDU_v1Traps.mib: MMU product version 1 trap MIB file

• ccm_SDIDU_v2Traps.mib: MMU product version 2 trap MIB file

Etherlike-MIB.mib - This MIB contains generic Ethernet interface parameters.

SONET-MIB.mib - This MIB contains parameters for configuring the SONET/SDH interface.

• RFC1573.mib - This MIB file contains access to interface parameters.

• RFC2493.mib - This MIB file contains performance history parameters.

• RFC1573.mib - This MIB file contains parameters for configuring SONET.

• RFC2558.mib - This MIB file contains parameters for configuring SONET data.

DS1-MIB.mib - This MIB file contains parameters for configuring DS1.

IANAifType-MIB.mib - This MIB file contains parameters for accessing interface data using IANA textual convention.

IF-MIB.mib - This MIB file contains parameters for accessing interface data.

PerfHist-TC-MIB.mib - This MIB file contains parameters for accessing performance data.

The SNMP agent interface uses these MIB files to configure the system.

Page 266: Cambium network ptp 810 series 01 00 user guide

Network management specifications Chapter 4: Reference information

4-78 phn-2779_001v000 (Jul 2012)

SNMP Agent Parameters

The SNMP agent interface configurable parameters are described in the following sections.

WEB and CLI interfaces can be used to configure the SNMP parameters below. Change in any of the parameters below reconfigures the agent.

If the agent is configured in ‘v3 only’ or ‘v1-v2-v3’ mode, SNMPv3 ‘admin’ user can configure the SNMP users. There are 3 possible levels of users.

The SNMP agent does not support level based access if the agent is configured as ‘v1 only’ or ‘v2 only’ mode. In the case of v1 and v2 modes of operation, Level1 access is given to the read operation and Level4 access is given for the write operation. Thus, in v1 and v2 modes of operation, the user has full access to system configurations if a valid write community string is used.

SNMP Mode

The SNMP agent can be configured to operate in any of the following modes:

• disable

• v1 only

• v2 only

• v3 only

• v1-v2-v3

If the agent is configured to run as v1 only, v2 only or v3 only, then the user can access the agent only using SNMP v1, v2 or v3 respectively.

If the agent is configured to operate in the v1-v2-v3 mode, then the user can access the agent using SNMP v1, v2 or v3.

The SNMP agent is disabled by selecting the disable mode.

In 1.4.18x non-encrypted version of the application, the v1-v2-v3 option is replaced by v1-v2 option.

SNMP v1 and v2 provides a weak security by using the community strings. The user can always configure the SNMP agent to operate in ‘v3 only’ mode, which uses authentication as well as encryption for secure transaction.

Page 267: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Electromagnetic compliance

phn-2779_001v000 (Jul 2012) 4-79

Electromagnetic compliance

This section describes how the PTP 810 complies with the regulations that are in force in various countries, and contains notifications made to regulatory bodies for the PTP 810.

Compliance testing

Changes or modifications not expressly approved by Cambium could void the user’s authority to operate the system.

This system has achieved Type Approval in various countries around the world. This means that the system has been tested against various local technical regulations and found to comply.

Electrical safety compliance

The PTP 810 hardware has been tested for compliance to the electrical safety specifications listed in Table 219.

Table 219 Electrical safety specifications

Region Specification

USA UL 60950-1

Canada CSA C22.2 No.60950-1

Europe EN 60950-1:2006, Amdt 11:2009

(This covers the essential requirements of the R&TTE Directive Article 3.1(a) Product Safety)

International CB certified & certificate to IEC 60950-1: 2005 Edition 2

Page 268: Cambium network ptp 810 series 01 00 user guide

Electromagnetic compliance Chapter 4: Reference information

4-80 phn-2779_001v000 (Jul 2012)

European Union compliance

RF performance

The PTP 810 system has been tested for compliance to harmonized European standard ETSI EN 302 217-2-2 Fixed Radio Systems; Characteristics and requirements for point-to-point equipment and antennas; Part 2-2: Digital systems operating in frequency bands where frequency co-ordination is applied; Harmonized EN covering the essential requirements of article 3.2 of the R&TTE Directive.

This covers the essential requirements of R&TTE directive Article 3.2 Effective Use of the Spectrum.

Electromagnetic compatibility

The PTP810 System has also been tested for compliance to the electro-magnetic compatibility standards given below:

• ETSI EN 301 489-4: Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 4: Specific conditions for fixed radio links, Broadband Data Transmission System Base stations, ancillary equipment and services.

• ETSI EN 301 489-1: Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements.

The limits for radiated and conducted radiations of Class A have been applied.

This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

This covers the essential requirements of R&TTE directive Article 3.1(b) Electromagnetic Compatibility.

Non-ionizing radiation

Radiation Hazard requirements of the R&TTE directive are covered in Radiation hazard assessment on page 4-83.

Canada compliance

The PTP 810 system has been verified for compliance to RSS-GEN and the band specific Technical Requirements documents in the SRSP series.

Page 269: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Electromagnetic compliance

phn-2779_001v000 (Jul 2012) 4-81

United States compliance

The PTP 810 system has been tested for compliance to FCC Code of Federal Regulations Title 47:

• Part 2: Frequency Allocations and Radio Treaty Matters; General Rules and Regulations.

• Part 15: Radio Frequency Devices.

• Part 101: Fixed Microwave Services.

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules and with RSS-GEN of Industry Canada. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Page 270: Cambium network ptp 810 series 01 00 user guide

Electromagnetic compliance Chapter 4: Reference information

4-82 phn-2779_001v000 (Jul 2012)

Notifications

General notification

Where necessary, the end user is responsible for obtaining any national licenses required to operate this product and these must be obtained before using the product in any particular country. Contact the appropriate national administrations for details on the conditions of use for the bands in question and any exceptions that might apply.

In order to reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the Effective Isotropic Radiated Power (EIRP) is not more than that permitted for successful communication.

European Union notification

The PTP 810 is a Class 2 device as it operates on frequencies that are not harmonized across the EU. See http://www.ero.dk for further information.

Hereby, Cambium Networks declares that the PTP 810 product complies with the essential requirements and other relevant provisions of Directive 1999/5/EC. The declaration of conformity may be consulted at the support web page (see Contacting Cambium Networks on page 2).

This equipment is marked to show compliance with the European R&TTE directive 1999/5/EC (Figure 64).

Figure 64 European Union compliance label

Page 271: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Radiation hazard assessment

phn-2779_001v000 (Jul 2012) 4-83

Radiation hazard assessment

This section evaluates the radiation levels produced by the PTP 810 products against ETSI and FCC standards.

ETSI method

This section evaluates the radiation levels produced by the PTP 810 products against the following standards:

• 1999/519/EC of 12 July 1999 on the limitation of exposure of the general public to electromagnetic fields (0 Hz to 300 GHz).

• EN 50385:2002 Product standard to demonstrate the compliances of radio base stations and fixed terminal stations for wireless telecommunication systems with the basic restrictions or the reference levels related to human exposure to radio frequency electromagnetic fields (110 MHz to 40 GHz) — general public.

• EN 50383:2002 Basic standard for the calculation and measurement of electromagnetic field strength and SAR related to human exposure from radio base stations and fixed terminal stations for wireless telecommunication systems (110 MHz to 40 GHz).

Exposure categories

EN 50385:2002 Clause 3.1 defines the restrictions on exposure to time-varying electric, magnetic, and electromagnetic fields that are based directly on established health effects. Between 10 GHz and 40 GHz, the physical quantity is the power density.

1999/519/EC defines the exposure limit (‘Basic Restriction’) to be considered for the general public. Annex II and Table 1 define this to be 10 W/m2.

Antenna directivity

The Cambium recommended antennas have Hi-Performance polar patterns in accordance with ETSI EN302 217-4-1 classes 2 and 3. They have gains in excess of 30 dB and beamwidths of less than 5 degrees. Thus, they provide high attenuation of radiated energy at the sides and rear of the antenna.

Page 272: Cambium network ptp 810 series 01 00 user guide

Radiation hazard assessment Chapter 4: Reference information

4-84 phn-2779_001v000 (Jul 2012)

Calculation

Calculation is used to identify the Compliance Boundary; outside this boundary the radiation levels meet the Basic Restriction, which is defined in 1999/519/EC as 10 W/m2.

The distance from the antenna at which the Power Flux Density limit is equal to some specified value is calculated using the Cylindrical Wave model as follows:

δπ DdPS 180.

=

Where S = Power density (W/m2), P = Maximum average transmit power capability of the radio (Watts), D = Antenna diameter (meters), d = Distance from point source (meters), δ = 3 dB antenna beamwidth (degrees).

Rearranging terms to solve for distance yields:

δπ DSP

d180.

=

Distances from antenna

Table 220 specifies calculated minimum separation distances for a range of frequency bands and antenna sizes at the peak of the antenna beam. At these and greater distances, the power density from the RF field is not considered to be hazardous.

Table 220 PTP 810 minimum separation distances, ETSI method

Band Antenna diameter

0.3 m (1 ft)

0.6 m (2 ft)

0.8 m (2.5 ft)

1.2 m (4 ft)

1.8 m (6 ft)

6 GHz N/A N/A N/A 1.7 m 1.8 m

7 and 8 GHz N/A 2.0 m 2.2 m 2.2 m 2.1 m

11 GHz N/A 1.8 m 2.2 m 2.0 m 1.8 m

13 GHz 1.6 m 1.4 m 1.4 m 1.5 m 1.4 m

15 GHz 1.8 m 1.5 m 1.6 m 1.6 m 1.6 m

18 GHz 2.1 m 1.6 m 1.7 m 1.9 m 1.6 m

23 GHz 2.0 m 1.8 m 2.0 m 2.0 m 2.0 m

26 GHz 2.4 m 2.0 m 2.3 m 2.5 m N/A

32 and 38 GHz 2.4 m 2.1 m N/A N/A N/A

Page 273: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Radiation hazard assessment

phn-2779_001v000 (Jul 2012) 4-85

These separation distances are significantly lower than those calculated by the method specified by the FCC. The ETSI method recognises that radiation is distributed across the antenna aperture and is not in reality a point source.

FCC method

Relevant standards (North America and EC) applicable when working with RF equipment are:

• ANSI IEEE C95.1-1991, IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz.

• US FCC limits for the general population. See the FCC web site at http://www.fcc.gov, and the policies, guidelines, and requirements in Part 1 of Title 47 of the Code of Federal Regulations, as well as the guidelines and suggestions for evaluating compliance in FCC OET Bulletin 65.

• Health Canada limits for the general population. See the Health Canada web site at http://www.hc-sc.gc.ca/ewh-semt/pubs/radiation/99ehd-dhm237/limits-limites_e.html and Safety Code 6.

• ICNIRP (International Commission on Non-Ionizing Radiation Protection) guidelines for the general public. See the ICNIRP web site at http://www.icnirp.de/ and Guidelines for Limiting Exposure to Time-Varying Electric, Magnetic, and Electromagnetic Fields.

Calculation

FCC OET Bulletin 65 specifies the far-field method to calculate power density:

24 RGPS

π=

Where S = Power density (W/m2), P = Maximum average transmit power capability of the radio (Watts), G = Antenna gain, R = Distance from point source (meters).

FCC Title 47 Part 1.1310 defines the exposure limit for the general population to be 10 W/m2 (1 mW/cm2) in the frequency range 1500 to 100,000 MHz. This defines an exposure time of 30 minutes. Higher levels are permitted for shorter periods of exposure.

Rearranging terms to solve for distance yields:

GPSR π4

=

Page 274: Cambium network ptp 810 series 01 00 user guide

Radiation hazard assessment Chapter 4: Reference information

4-86 phn-2779_001v000 (Jul 2012)

Distances from antenna

For ODU deployments, Table 221 specifies calculated minimum separation distances for a range of frequency bands and antenna sizes at the peak of the antenna beam. At these and greater distances, the power density from the RF field is not considered to be hazardous. These tables are based on the worst case transmit power.

Table 221 PTP 810 minimum separation distances, FCC method (ODU)

Band Antenna diameter

0.3 m (1 ft)

0.6 m (2 ft)

0.8 m (2.5 ft)

1.2 m (4 ft)

1.8 m (6 ft)

6 GHz 7 GHz 8 GHz

N/A N/A N/A 2.7 m (8.8 ft)

4.2 m (13.6 ft)

11 GHz N/A 1.9 m (6.3 ft)

2.7 m (8.9 ft)

3.7 m (12.2 ft)

5.6 m (18.4 ft)

18 GHz 2.9 m (9.6 ft)

4.8 m (15.8 ft)

6.3 m (20.7 ft)

9.6 m (31.5 ft)

14.0 m (46.0 ft)

23 GHz 3.0 m (9.9 ft)

5.4 m 17.8 ft)

7.1 m (23.3 ft)

10.7 m (35.2 ft)

14.9 m (48.9 ft)

26 GHz 3.4 m (11.2 ft)

5.9 m (19.4 ft)

8.0 m (26.3 ft)

11.7 m (38.4 ft)

N/A

38 GHz 4.0 m (13.2 ft)

7.4 m (24.3 ft)

N/A N/A N/A

Page 275: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide

phn-2779_001v000 (Jul 2012) 5-1

Chapter 5: Installation

This chapter describes how to install and test the hardware for a PTP 810 link.

Before starting the installation, refer to:

• Preparing for installation on page 5-2 describes the checks to be performed before proceeding with the installation.

To install the ODU and IF cables, refer to:

• Installing antennas and ODUs on page 5-5 describes how to install the antennas, ODUs and waveguide connections at each link end.

• Installing the IF and ground cables on page 5-38 describes how to install the IF cables and how to install grounding and lightning protection.

• Testing the ODU and IF cable on page 5-63 describes how to perform pre-power tests on the ODU, LPUs and IF cable.

To install the MMU and network connections, refer to:

• Installing the MMU on page 5-71 describes how to mount the MMU in the building or cabinet, and to connect it to ground, power supply and PC.

• Preparing network connections (1+0 and 2+0 links) on page 5-77 describes how to prepare the cables to connect the MMU to the customer and (optionally) management networks. It applies only to unprotected ends (1+0 and 2+0 links).

Page 276: Cambium network ptp 810 series 01 00 user guide

Preparing for installation Chapter 5: Installation

5-2 phn-2779_001v000 (Jul 2012)

Preparing for installation

Before starting the installation, perform the checks described in this section.

Safety precautions during installation

When developing a site, installing equipment, or performing maintenance, ensure that all national and local safety standards are followed by all personnel.

Ensure that personnel are not exposed to unsafe levels of RF energy. The units start to radiate as soon as they are powered up. Respect the safety standards defined in Radiation hazard assessment on page 4-83, in particular the minimum separation distances.

Observe the following guidelines:

• Never work in front of the antenna when the MMU is powered.

• Always power down the MMU before connecting or disconnecting the drop cable from the MMU, ODU or LPU.

Grounding and lightning protection requirements

Ensure that the installation meets the requirements defined in Grounding and lightning protection on page 2-7.

Selecting installation options

Use the installation report to determine which installation options are required. Refer to Link planning on page 2-2.

When installing a 1+1 Hot Standby link, refer to Planning 1+1 links on page 2-25 for an overview of alternative hardware configurations.

Page 277: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Preparing for installation

phn-2779_001v000 (Jul 2012) 5-3

Preparing personnel

In no event shall Cambium Networks be liable for any injury or damage caused during the installation of the Cambium PTP 810.

Ensure that only qualified personnel undertake the installation of a PTP 810 link.

Ensure that all safety precautions are observed.

Preparing inventory

Perform the following inventory checks:

• Check that an installation report is available and that it is based on the principles described in Chapter 2: Planning considerations.

• Check that the correct components are available, as described Ordering components on page 2-39.

• Check the contents of all packages against their packing lists.

Preparing tools

Check that the tools listed in Table 222 are available.

Table 222 Tools required for PTP 810 installation

Equipment to be Installed Tools Required

MMU Pozi screw driver (PZ1)

Ground lug crimp tool (diameter 5mm)

8mm spanner

Direct Mount ODU Lubricant (supplied)

Remote Mount 17mm spanner

Lubricant (supplied)

Flexible Wave Guide Allen key (supplied in the kit)

Flexible Wave Guide hanger 13mm spanner

5mm Allen key

Flat bladed screw driver (6mm) or

Pozi screw driver (PZ2)

Page 278: Cambium network ptp 810 series 01 00 user guide

Preparing for installation Chapter 5: Installation

5-4 phn-2779_001v000 (Jul 2012)

Equipment to be Installed Tools Required

Coupler 6mm Allen key

2.5mm and 3mm Allen keys (supplied)

Lubricant (supplied)

Antenna 17mm spanner

7 mm spanner (for tapered transition)

Voltmeter and BNC lead

Compass and GPS meter

Inclinometer

Cable Cable cutters

Cable hoist

Flat file to dress the cable inner core

Wire brush to comb the braid

Crimp tool Cambium part 66010063001

Torque wrench

Page 279: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Installing antennas and ODUs

phn-2779_001v000 (Jul 2012) 5-5

Installing antennas and ODUs

This section describes how to install the antennas, ODUs and waveguide connections at each link end.

Use Table 223 to select installation procedures.

Table 223 Selecting antenna and ODU installation procedures

Hardware configuration

Antenna mounting

Procedures to be performed

1+0 Direct Installing a direct mount antenna with one ODU on page 5-6.

1+0 Remote Installing a remote mount antenna with one ODU on page 5-10.

1+1 HSB Direct Installing a direct mount antenna with two ODUs (via coupler) on page 5-21.

1+1 HSB Remote Installing a remote mount antenna with two ODUs (via coupler) on page 5-28.

1+1 HSB SD Direct Installing a direct mount antenna with one ODU on page 5-6. Repeat for the second antenna and ODU.

1+1 HSB SD Remote Installing a remote mount antenna with one ODU on page 5-10. Repeat for the second antenna and ODU.

Dual 1+0 Direct Installing a direct mount antenna with one ODU on page 5-6. Repeat for the second antenna and ODU.

Dual 1+0 Remote Installing a remote mount antenna with one ODU on page 5-10. Repeat for the second antenna and ODU.

2+0 co-polar Direct Installing a direct mount antenna with two ODUs (via coupler) on page 5-21.

2+0 co-polar Remote Installing a remote mount antenna with two ODUs (via coupler) on page 5-28.

2+0 cross-polar Direct Installing a direct mount dual-polar antenna with two ODUs on page 5-34.

2+0 cross-polar Remote Installing a remote mount antenna with one ODU on page 5-10. Install two ODUs and waveguides and one dual-polar antenna, but connect both ODUs to the antenna via the waveguide ports.

2+0 XPIC Direct Installing a direct mount dual-polar antenna with two ODUs on page 5-34.

Page 280: Cambium network ptp 810 series 01 00 user guide

Installing antennas and ODUs Chapter 5: Installation

5-6 phn-2779_001v000 (Jul 2012)

Hardware configuration

Antenna mounting

Procedures to be performed

2+0 XPIC Remote Installing a remote mount antenna with one ODU on page 5-10. Install two ODUs and waveguides and one dual-polar antenna, but connect both ODUs to the antenna via the waveguide ports.

Follow applicable health and safety rules for use of silicone grease. If necessary use the latex gloves supplied with the products.

If upgrading an unprotected link to 1+1 Hot Standby, mute the active unit before installing the coupler. For safety reasons this is required when working with the ODUs or when working close to the antenna. See Disabling, enabling, muting and unmuting the ODU on page 7-21.

When installing 1+1 Hot Standby links, observe that the ODUs are labeled ‘Hi’ or ‘Lo’ depending on the frequency sub-band. Install the two ‘Hi’ ODUs at one end of the link and the two ‘Lo’ ODUs at the other end.

Installing a direct mount antenna with one ODU

In the direct mount configuration, attach the ODU directly to the antenna (with Cambium ODU interface) via four latches.

To install a direct mount antenna with a single ODU, proceed as follows:

1 Follow the antenna manufacturer’s instructions to attach the antenna to its bracket.

Page 281: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Installing antennas and ODUs

phn-2779_001v000 (Jul 2012) 5-7

2 Polarization depends upon the antenna waveguide interface position. To change polarization, rotate the antenna transition, following the antenna manufacturer’s instructions.

3 Apply silicone grease to the ‘O’ Ring of the antenna transition.

4 Remove the ODU waveguide interface dust cover.

Page 282: Cambium network ptp 810 series 01 00 user guide

Installing antennas and ODUs Chapter 5: Installation

5-8 phn-2779_001v000 (Jul 2012)

5 Fit the ODU to the antenna transition, ensuring that the antenna and ODU waveguide interfaces align correctly. Observe the polarization of the antenna waveguide interface.

6 Secure the ODU to the antenna with the four latches, taking care to ensure they are correctly engaged.

7 Check that the antenna, mounting bracket and ODU are assembled.

Page 283: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Installing antennas and ODUs

phn-2779_001v000 (Jul 2012) 5-9

8 Follow the manufacturer’s instructions to attach the assembly to the mast or pole.

Page 284: Cambium network ptp 810 series 01 00 user guide

Installing antennas and ODUs Chapter 5: Installation

5-10 phn-2779_001v000 (Jul 2012)

Installing a remote mount antenna with one ODU

In the remote mount configuration, the antenna and ODU are attached to the mast separately, connected to each other via a flexible waveguide. The flexible waveguide is designed to isolate vibration and eliminate difficulties caused by misalignment.

The flexible waveguide must be protected from damage that may be caused by contamination, vibration or bending.

When installing a flexible waveguide, observe the following precautions:

• Unpacking: To avoid damage to the waveguide, do not unpack it until required. When unpacked, protect the waveguide from dirt, dust or ingress of foreign objects.

• Vibration: Flexible waveguides may be damaged if subjected to excessive vibration or excessive bending. If a flexible waveguide is installed in a stressed (tensile) condition, vibration should be kept to a minimum, as the waveguide rubber jacket may become more susceptible to ozone and general environmental attack. Always use the waveguide hangers; two hangers should be used for the 900mm (3ft) flexible waveguide.

• Bend radius: Conform to the bend radii, maximum twist and torque settings specified in Flexible waveguide specifications on page 4-9.

• Static bend radius: When installing a flexible waveguide, pay attention to the static bend radius (quoted in the waveguide manufacturer’s data sheet). Static bend radius is the minimum bend that an assembly may be subject to without repeat movement (except as a consequence of small vibrations or axial expansions).

Before installation, check that the ODU, RMK, waveguide and antenna have compatible interfaces.

For a 2+0 cross-polar remote mount configuration, follow the procedures in this section to install two ODUs and waveguides and one dual-polar antenna, but connect both ODUs to the antenna via the waveguide ports (Figure 65).

Page 285: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Installing antennas and ODUs

phn-2779_001v000 (Jul 2012) 5-11

Figure 65 Dual-polar antenna in remote mount configuration

Page 286: Cambium network ptp 810 series 01 00 user guide

Installing antennas and ODUs Chapter 5: Installation

5-12 phn-2779_001v000 (Jul 2012)

Mounting ODU on pole using RMK

To mount the ODU on the pole using a remote mounting kit (RMK), proceed as follows:

1 Follow the manufacturer’s instructions to attach the RMK to the mast or pole.

2 Apply silicone grease to the ‘O’ ring of the RMK transition.

3 Remove the ODU waveguide interface dust cover.

Page 287: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Installing antennas and ODUs

phn-2779_001v000 (Jul 2012) 5-13

4 Fit the ODU to the RMK transition, ensuring that the locating pegs on the RMK transition fit into the peg holes in the ODU waveguide interface.

5 Secure the ODU to the RMK with the four latches, taking care to ensure they are correctly engaged.

Page 288: Cambium network ptp 810 series 01 00 user guide

Installing antennas and ODUs Chapter 5: Installation

5-14 phn-2779_001v000 (Jul 2012)

6 Check that the RMK and ODU are correctly mounted on the mast or pole.

Assembling the flexible waveguide hangers

To provide adequate support for a 900mm flexible waveguide, install two hangers. To assemble the flexible waveguide hangers, proceed as follows:

1 Check the flexible waveguide hanger kit contents.

2 Assemble the pole clip, making note of the angle of the slots in the metal strip.

Page 289: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Installing antennas and ODUs

phn-2779_001v000 (Jul 2012) 5-15

3 Fit the rubber moulding clamp to the studding.

4 Use the 5mm Allen key to fit the pole clip to the studding.

5 Temporarily fit the rubber mouldings.

6 Check the finished assembly.

Page 290: Cambium network ptp 810 series 01 00 user guide

Installing antennas and ODUs Chapter 5: Installation

5-16 phn-2779_001v000 (Jul 2012)

Attaching antenna and waveguide to pole

If the antenna is 11 GHz, fit a tapered transition between the antenna and waveguide as described in Mounting an 11 GHz antenna with tapered transition and waveguide on page 5-19.

To mount the antenna on the pole and attach it to the ODU via the flexible waveguide, proceed as follows:

1 Follow the antenna manufacturer’s instructions to attach the antenna to its bracket and to the mast or pole.

2 Check that the waveguide, antenna and RMK have compatible interfaces. Check that the mating surfaces are clean and free from damage.

3 Fit one of the ‘O’ ring seals supplied with the waveguide kit to the flexible waveguide flange that has the O ring groove.

4 Using the waveguide flange fitted with the ‘O’ ring, fit the flexible waveguide to the remote mount. Ensure that the waveguide cavity orientation matches the opening in the RMK. Fit four shorter screws, using a spring washer and a plain washer on each screw. It is sometimes more convenient to complete this operation before the assembly is fitted to the mast, connecting the flexible waveguide to the antenna when fitting the remote mount to the mast.

Page 291: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Installing antennas and ODUs

phn-2779_001v000 (Jul 2012) 5-17

5 Fit the remote mount to the tower. Fit an ‘O’ ring seal to the antenna interface and secure the plain flange of flexible waveguide to the antenna. Ensure that the waveguide cavity orientation matches the opening in the antenna. Secure the flexible waveguide using four of the shorter screws to the antenna. Fit each screw with a spring washer and a plain washer.

6 Fit the rubber inserts from the hanger kit to the flex waveguide.

7 Insert the rubber insert and flex waveguide into the hanger.

Page 292: Cambium network ptp 810 series 01 00 user guide

Installing antennas and ODUs Chapter 5: Installation

5-18 phn-2779_001v000 (Jul 2012)

8 Fit the hanger cover and tighten.

9 When routing the flex waveguide ensure that the minimum bend radius is not exceeded.

Page 293: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Installing antennas and ODUs

phn-2779_001v000 (Jul 2012) 5-19

10 Check the complete assembly.

Mounting an 11 GHz antenna with tapered transition and waveguide

When installing an 11 GHz remote mount antenna, fit a tapered transition between the antenna and the flexible waveguide. The tapered transition converts from the PDR100 waveguide flange on the antenna to the UBR120 flange on the flexible waveguide.

11 GHz antennas with a CPR90G interface need a different flexible waveguide and have the tapered transition next to the RMK not the antenna. Ensure that flanges are matched accordingly.

Page 294: Cambium network ptp 810 series 01 00 user guide

Installing antennas and ODUs Chapter 5: Installation

5-20 phn-2779_001v000 (Jul 2012)

To mount an 11 GHz antenna with taper transition and flexible waveguide, proceed as follows:

1 Mount the bracket on the antenna.

2 Remove the protective film from the antenna waveguide and fit the gasket, (supplied in the kit).

3 Use the 8 screws to fit the tapered transition to the antenna.

Page 295: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Installing antennas and ODUs

phn-2779_001v000 (Jul 2012) 5-21

4 Fit the seal to the tapered transition, (supplied in the kit).

5 Use the four screws supplied in the kit to fit the flexible waveguide to the tapered transition. It makes taping the joint easier if the four screws are inserted in the direction shown.

6 Use FT-TB fusion tape (Andrews part FT-TB) to water proof the junctions as shown.

Installing a direct mount antenna with two ODUs (via coupler)

In the direct mount configuration, attach the coupler (with ODUs) directly to the antenna (with Cambium ODU interface) via four latches.

Page 296: Cambium network ptp 810 series 01 00 user guide

Installing antennas and ODUs Chapter 5: Installation

5-22 phn-2779_001v000 (Jul 2012)

If the coupler is asymmetric, one side is embossed with the word ‘MAIN’ and the other side with ‘STANDBY’ (Figure 66). The ‘MAIN’ side has lower loss. Ensure that the ‘MAIN’ and ‘STANDBY’ sides can still be identified after the ODUs are fitted, as this allows them to be connected to the correct modem in the MMU.

Figure 66 Words embossed on coupler

Attaching coupler to antenna

To attach the coupler to the antenna, proceed as follows:

1 Follow the antenna manufacturer’s instructions to attach the antenna to its bracket.

Page 297: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Installing antennas and ODUs

phn-2779_001v000 (Jul 2012) 5-23

2 Check that the supplied coupler is the correct type for this installation. Check the contents of the coupler mounting kit.

3 Fit the correct spacers to each of the four legs:

11GHz - spacer length 27mm

18 GHz, 23 GHz, and 26 GHz - spacer length 7.75mm.

Page 298: Cambium network ptp 810 series 01 00 user guide

Installing antennas and ODUs Chapter 5: Installation

5-24 phn-2779_001v000 (Jul 2012)

4 For a 1+1 Hot Standby link, check that the circular transitions on the coupler have the same alignment (vertical or horizontal depending on the antenna polarity).

If necessary, rotate the circular transitions according to the manufacturer’s instructions.

5 Take note of the word ‘TOP’ embossed in the casting; ensure this edge is upper most when attached to the antenna.

6 Remove protective film from coupler antenna port.

Page 299: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Installing antennas and ODUs

phn-2779_001v000 (Jul 2012) 5-25

7 Apply silicone grease to the ‘O’ Ring of the antenna transition.

8 Fit the coupler to the antenna by following this sequence:

Initially, hand-tighten two of the diagonally opposed M8 bolts with the Allen key supplied in the kit.

Using the latch clamp, clip the same two corners.

Repeat the above on the remaining two diagonally opposed bolts and clips.

Torque down all four M8 bolts to 18 Nm.

Page 300: Cambium network ptp 810 series 01 00 user guide

Installing antennas and ODUs Chapter 5: Installation

5-26 phn-2779_001v000 (Jul 2012)

Attaching ODUs to coupler

To attach the ODUs to the coupler and mount the assembly on the pole, proceed as follows:

1 Remove protective film from the coupler ports.

2 Apply silicone grease to the ‘O’ rings of the coupler transitions.

3 Fit the ODUs to the coupler transitions, ensuring that the waveguide interfaces align correctly for vertical or horizontal polarization. Fit both ODUs such that handles are at the top and connectors at the bottom. For asymmetric couplers, check that the ‘MAIN’ and ‘STANDBY’ sides of the coupler can still be identified.

Page 301: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Installing antennas and ODUs

phn-2779_001v000 (Jul 2012) 5-27

4 Follow the manufacturer’s instructions to attach the assembly to the mast or pole.

5 Check the finished installation.

Page 302: Cambium network ptp 810 series 01 00 user guide

Installing antennas and ODUs Chapter 5: Installation

5-28 phn-2779_001v000 (Jul 2012)

Installing a remote mount antenna with two ODUs (via coupler)

In the remote mount configuration, attach the antenna and coupler (with two ODUs) to the mast separately, connected to each other via a flexible waveguide. The flexible waveguide is designed to isolate vibration and eliminate difficulties caused by misalignment.

Protect the flexible waveguide from damage that may be caused by contamination, vibration or bending. Observe the precautions in Installing a remote mount antenna with one ODU on page 5-10.

Before installation, check that the ODUs, coupler, RMK, waveguide and antenna have compatible interfaces.

If the coupler is asymmetric, one side is embossed with the word ‘MAIN’ and the other side with ‘STANDBY’ (Figure 66). The ‘MAIN’ side has lower loss. Ensure that the ‘MAIN’ and ‘STANDBY’ sides can still be identified after the ODUs are fitted, as this allows them to be connected to the correct MMUs.

Attaching coupler to RMK

To attach the coupler to the RMK, proceed as follows:

1 Ensure the correct RMK, coupler and flexible waveguide are present for the frequency band.

Page 303: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Installing antennas and ODUs

phn-2779_001v000 (Jul 2012) 5-29

2 Check that the supplied coupler is the correct type for this installation. Check the contents of the coupler mounting kit.

3 Fit the correct spacers to each of the four legs:

11GHz - spacer length 27mm

18 GHz, 23 GHz and 26 GHz - spacer length 7.75mm

Page 304: Cambium network ptp 810 series 01 00 user guide

Installing antennas and ODUs Chapter 5: Installation

5-30 phn-2779_001v000 (Jul 2012)

4 Check that the circular transition on the coupler is correctly aligned for remote mount bracket polarity (vertical or horizontal). If necessary, rotate the circular transition according to the manufacturer’s instructions.

5 Take note of the polarization marks on the remote mount bracket.

6 Take note of the word ‘TOP’ embossed in the casting; ensure this edge is upper most when attached to the antenna.

Page 305: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Installing antennas and ODUs

phn-2779_001v000 (Jul 2012) 5-31

7 Remove the protective film from the coupler remote mount port.

8 Apply silicone grease to the ‘O’ ring of the remote mount transition.

9 Fit the coupler to the remote mount bracket by following this sequence:

Initially, hand tighten two of the diagonally opposed M8 bolts with the Allen Key supplied in the kit.

Using the latch clamp, clip the same two corners.

Repeat the above on the remaining two diagonally opposed bolts and clips.

Torque down all four M8 bolts to 18Nm.

Assembling the flexible waveguide hangers

Assemble the hangers as described in Assembling the flexible waveguide hangers on page 5-14.

Page 306: Cambium network ptp 810 series 01 00 user guide

Installing antennas and ODUs Chapter 5: Installation

5-32 phn-2779_001v000 (Jul 2012)

Attaching antenna to pole

Follow the antenna manufacturer’s instructions to attach the antenna to its bracket and to the mast or pole.

Attaching ODUs to coupler

To attach the ODUs to the coupler and mount the assembly on the pole, proceed as follows:

1 Fit the flex waveguide to the remote mount bracket.

2 Fit assembly to pole.

Page 307: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Installing antennas and ODUs

phn-2779_001v000 (Jul 2012) 5-33

3 Connect the flexible waveguide to the antenna.

4 Remove protective film from coupler ports.

5 Apply silicone grease to the ‘O’ rings of the coupler transitions.

6 Fit the ODUs to the coupler transitions, ensuring that the waveguide interfaces align correctly for vertical or horizontal polarization. Fit both ODUs such that handles are at the top and connectors at the bottom. For asymmetric couplers, check that the ‘MAIN’ and ‘STANDBY’ sides of the coupler can still be identified.

Page 308: Cambium network ptp 810 series 01 00 user guide

Installing antennas and ODUs Chapter 5: Installation

5-34 phn-2779_001v000 (Jul 2012)

7 Support the flexible waveguide with the waveguide hangers. Do not exceed the flexible waveguide minimum bend radius.

8 Check the finished installation.

Installing a direct mount dual-polar antenna with two ODUs

Direct mount dual-polar antennas are supplied with an orthogonal mode transducer (OMT) with two direct-mount interfaces.

To upgrade any standard antenna to a direct mount dual polar antenna, purchase an orthogonal mount kit (OMK) from Cambium.

Page 309: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Installing antennas and ODUs

phn-2779_001v000 (Jul 2012) 5-35

To install a direct mount dual-polar antenna with two ODUs, proceed as follows:

1 Follow the manufacturer’s instructions to fit the antenna mounting bracket and fit the antenna to the orthogonal mode transducer.

2 Remove protective film from the OMT transitions.

Page 310: Cambium network ptp 810 series 01 00 user guide

Installing antennas and ODUs Chapter 5: Installation

5-36 phn-2779_001v000 (Jul 2012)

3 Apply silicone grease to the ‘O’ rings of the OMT transitions.

4 Fit the ODUs to the transitions, ensuring that the waveguide interfaces align correctly for vertical or horizontal polarization.

5 Follow the manufacturer’s instructions to attach the assembly to the mast or pole.

Page 311: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Installing antennas and ODUs

phn-2779_001v000 (Jul 2012) 5-37

6 Place the supplied spirit level on the leveling flat and use it to achieve horizontal alignment of the antenna and OMT assembly.

To confirm that the assembly is level, place an inclinometer on the leveling flat and measure inclination angle. The example shows an inclination of 0.2°.

Page 312: Cambium network ptp 810 series 01 00 user guide

Installing the IF and ground cables Chapter 5: Installation

5-38 phn-2779_001v000 (Jul 2012)

Installing the IF and ground cables

This section describes how to install the IF cables and how to install grounding and lightning protection.

When installing a 1+1 Hot Standby link, install and ground separate IF cables for the Primary and Secondary ODUs.

When installing a 2+0 link, install and ground separate IF cables for the link A and link B ODUs.

This task consists of the following procedures:

• Preparing IF cables on page 5-40.

• Fitting an N type or straight TNC connector on page 5-40.

• Connecting the ODU to the top LPU on page 5-44.

• Weatherproofing an N type connector on page 5-47.

• Hoisting the main IF cable on page 5-52.

• Installing and grounding the main IF cable on page 5-55.

• Making an IF cable ground point on page 5-57.

• Installing and grounding the IF cable at building entry on page 5-61.

When installing IF and ground cables, observe the following precautions:

o Ensure that the IF and ground cable installation meets the requirements defined in Grounding and lightning protection on page 2-7.

o To provide effective protection against lightning induced surges, grounding cables must be installed without drip loops and pointing down towards the ground.

o To ensure that IF connections are not damaged by water ingress, all outdoor IF connectors must be protected from the weather with self-amalgamating and vinyl tape.

o Do not connect or disconnect the IF cable when the power supply is applied to the MMU.

o Always ensure the lightning protection units are connected the correct way round (Figure 67).

Page 313: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Installing the IF and ground cables

phn-2779_001v000 (Jul 2012) 5-39

Figure 67 Correct orientation of LPUs

MMU

EQUIPMENT port

SURGE port

EQUIPMENT port

SURGE port

ODU Antenna

Top LPU

Bottom LPU

Page 314: Cambium network ptp 810 series 01 00 user guide

Installing the IF and ground cables Chapter 5: Installation

5-40 phn-2779_001v000 (Jul 2012)

Preparing IF cables

Prepare the following lengths of IF cable:

• ‘ODU-LPU’ IF cable: To connect the ODU to the top LPU, use the braided cable assembly supplied in the coaxial cable installation assembly kit (Table 55), as this is pre-fitted with N type connectors. If this is not suitable, cut a short section of IF cable and fit N type connectors to both ends, as described in Fitting an N type or straight TNC connector on page 5-40.

• ‘Main’ IF cable: Cut a length of IF cable to connect the top LPU to the bottom LPU. Slide one or more hoisting grips onto the top end of the cable, as described in Hoisting the main IF cable on page 5-52. Fit N type connectors to both ends, as described in Fitting an N type or straight TNC connector on page 5-40.

• ‘LPU-MMU’ IF cable: Cut a length of IF cable to connect the bottom LPU to the MMU. Fit an N type connector to the LPU end, as described in Fitting an N type or straight TNC connector on page 5-40. For the MMU end, choose one of the following options:

o To fit a right angle TNC male connector, follow the procedure Fitting a right angle TNC connector on page 5-44.

o To fit a straight TNC male connector, follow the procedure Fitting an N type or straight TNC connector on page 5-40.

o To fit an N type connector, follow the procedure Fitting an N type or straight TNC connector on page 5-40, then fit the N-Type to TNC Adapter (Cambium part number N000081L007).

Fitting an N type or straight TNC connector

Prerequisites:

• CNT-400 coaxial cable, 50 Ω (IF cable) (Cambium part number 30010194001 or 30010195001), cut to length.

• Crimp tool for N-type and TNC connectors (Cambium part number 66010063001).

• For ODU or LPU connections: N type connector supplied in Coaxial cable installation assembly kit (Cambium part number WB3616).

• For MMU connections: TNC Male for CNT-400 braided cable (Cambium part number N000081L005A).

• Grease, ruler, file, wire brush, cable cutter.

Page 315: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Installing the IF and ground cables

phn-2779_001v000 (Jul 2012) 5-41

To prepare an IF cable to receive an N type or straight TNC connector, proceed as follows:

1 Remove 21mm (0.827 inch) of the outer jacket:

2 Slide ferrule over braid, ensure the chamfer is towards the braid:

3 Comb braid straight with wire brush:

4 Fold braid around ferrule, ensuring that it is straight and equally spaced. Trim braid back to 9mm (0.354 inch):

5 Remove foam insulation and trim centre conductor to 6mm (0.236 inch):

Page 316: Cambium network ptp 810 series 01 00 user guide

Installing the IF and ground cables Chapter 5: Installation

5-42 phn-2779_001v000 (Jul 2012)

6 Chamfer the centre conductor at a angle of 45°:

Failure to correctly chamfer the centre conductor will cause damage to the connector when assembling the cable into the connector.

7 Mark a line 22 mm from the end of the ferrule:

8 Daub grease onto the braid uniformly:

Page 317: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Installing the IF and ground cables

phn-2779_001v000 (Jul 2012) 5-43

To crimp an N type or straight TNC connector to an IF cable, proceed as follows:

1 Insert the cable into connector. The cable centre conductor must be inserted into the inner contact fingers:

2 Ensure that the cable is not inserted beyond the line marked in Step 8.

Crimp the connector body in the area shown:

3 Use the larger of the openings in the crimp tool:

4 Check the finished part:

Page 318: Cambium network ptp 810 series 01 00 user guide

Installing the IF and ground cables Chapter 5: Installation

5-44 phn-2779_001v000 (Jul 2012)

Fitting a right angle TNC connector

Prerequisites:

• CNT-400 coaxial cable, 50 Ω (IF cable) (Cambium part number 30010194001 or 30010195001), cut to length.

• TNC Male Right Angle for CNT-400 braided cable (Cambium part number N000081L006A).

• Spanner, ruler, file, wire brush, cable cutter.

To fit a right angle TNC connector, follow manufacturer’s instructions.

Connecting the ODU to the top LPU

Perform this procedure to connect the ODU to the top lightning protection unit (LPU) via ground and IF cables, and to ground the LPU to the supporting structure (Figure 68).

Figure 68 ODU and top LPU grounding

To connect and ground the ODU and top LPU, proceed as follows:

Page 319: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Installing the IF and ground cables

phn-2779_001v000 (Jul 2012) 5-45

1 Attach one end of the ODU ground cable to the ODU.

2 Attach the other end of the ODU ground cable to the top LPU, under the LPU mounting nut. Attach one end of the LPU ground cable to the LPU, under the LPU mounting nut.

Page 320: Cambium network ptp 810 series 01 00 user guide

Installing the IF and ground cables Chapter 5: Installation

5-46 phn-2779_001v000 (Jul 2012)

3 Attach one end of the ODU-LPU IF cable to the ODU.

4 Attach the other end of the ODU-LPU IF cable to the EQUIPMENT port of the top LPU.

5 Mount the top LPU on the supporting structure.

6 Route and fasten the ODU ground cable and ODU-LPU IF cable. The ground cable should be routed downwards without any loops.

Page 321: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Installing the IF and ground cables

phn-2779_001v000 (Jul 2012) 5-47

7 Attach the other end of the LPU ground cable to the grounding bar of the supporting structure.

8 Protect the N type connectors at the ODU and LPU from the weather by applying self-amalgamating and PVC tape, as described in Weatherproofing an N type connector on page 5-47.

Weatherproofing an N type connector

Use this procedure to weatherproof the N type connectors fitted to the ODU and LPU.

Before weatherproofing the connectors, ensure that the installation has been tested as described in Testing the ODU and IF cable on page 5-63. These tests require connection and disconnection of the IF cables at various places.

Tighten N type connectors using a torque wrench, set to 1.7 Nm (15 lb in). If a torque wrench is not available, finger tighten the N type connectors.

To weatherproof an N type connector, proceed as follows:

Page 322: Cambium network ptp 810 series 01 00 user guide

Installing the IF and ground cables Chapter 5: Installation

5-48 phn-2779_001v000 (Jul 2012)

1 Ensure the connection is tight, using a torque wrench (if available):

2 Wrap the connection with a layer of 19 mm (0.75 inch) PVC tape, starting 25 mm (1 inch) below the connector body. Overlap the tape to half-width and extend the wrapping to the body of the LPU. Avoid making creases or wrinkles:

3 Smooth tape edges:

Page 323: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Installing the IF and ground cables

phn-2779_001v000 (Jul 2012) 5-49

4 Cut a 125mm (5 inches) length of rubber tape (self amalgamating):

5 Expand the width of the tape by stretching it so that it will wrap completely around the connector and cable:

6 Press the tape edges together so that there are no gaps. The tape should extend 25mm (1inch) beyond the PVC tape:

Page 324: Cambium network ptp 810 series 01 00 user guide

Installing the IF and ground cables Chapter 5: Installation

5-50 phn-2779_001v000 (Jul 2012)

7 Wrap a layer of 50 mm (2 inch) PVC tape from bottom to top, starting from 25 mm (1 inch) below the edge of the self-amalgamating tape, overlapping at half width.

8 Repeat with a further four layers of 19 mm (0.75 inch) PVC tape, always overlapping at half width. Wrap the layers in alternate directions:

Second layer: top to bottom.

Third layer: bottom to top.

Fourth layer: top to bottom.

Fifth layer: bottom to top.

The bottom edge of each layer should be 25 mm (1 inch) below the previous layer.

Page 325: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Installing the IF and ground cables

phn-2779_001v000 (Jul 2012) 5-51

9 Completed weatherproof connection:

Page 326: Cambium network ptp 810 series 01 00 user guide

Installing the IF and ground cables Chapter 5: Installation

5-52 phn-2779_001v000 (Jul 2012)

Hoisting the main IF cable

Use hoisting grips to hoist the main IF cable safely up a tower or building and provide permanent support so that mechanical connection to an antenna can be made. The correct hoisting grip for CNT-400 IF cable is Cambium part number 07009304001, used with the correct crimp tool SG-IT (Andrew part number 243333).

Failure to obey the following precautions may result in injury or death.

Observe the following precautions:

• Use the hoisting grip to hoist one cable only. Attempting to hoist more than one cable may cause the hoisting grip to break or the cables to fall.

• Do not use the hoisting grip for lowering cable unless the clamp is securely in place.

• Do not reuse hoisting grips. Used grips may have lost elasticity, stretched, or become weakened. Reusing a grip can cause the cable to slip, break, or fall.

• Use hoisting grips at intervals of no more than 60 m (200 ft).

• Use the proper hoisting grip for the cable being installed. If the wrong hoisting grip is used, slippage or insufficient gripping strength will result.

Attaching the hoisting grip

Attach one or more hoisting grips to the main IF cable before fitting the N type connector to the top end (as described in Preparing IF cables on page 5-40). Attach one additional hoisting grip for each 60 m (200 ft) of cable.

Page 327: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Installing the IF and ground cables

phn-2779_001v000 (Jul 2012) 5-53

To attach a hoisting grip to the main IF cable, proceed as follows:

1 Compress the grip ends towards each other and slide the grip heel (woven end) onto the cable (see photo). Place the hoisting grip(s) at the proper location on the cable before attaching the connector. Allow a sufficient length of cable leader to reach the antenna connector when cable hoisting and attachment of the grip handle is completed. Hold the heel with one hand and firmly slide the other hand along the grip to tighten it.

2 Slide the clamp onto the grip and position it 25 mm (1”) from the heel.

3 Crimp the clamp with Andrew crimping tool 243333 at each hoisting grip clamp location.

Page 328: Cambium network ptp 810 series 01 00 user guide

Installing the IF and ground cables Chapter 5: Installation

5-54 phn-2779_001v000 (Jul 2012)

Using the hoist line

Maintain tension on the hoisting grip during hoisting. Loss of tension can cause dangerous movement of the cable and result in injury or death to personnel on or near the tower. Also, do not release tension on the grip until after the cable has been fastened to the tower members.

Attach the hoist line to the grip (Figure 69). Tie the cable leader to the hoist line so that the leader does not dangle. Apply tension slowly to the hoist line, allowing the hoisting grip to tighten uniformly on the cable. Hoist the main IF cable up to the ODU.

Figure 69 Using the hoist line

Minimum leader 1.5 m

(5 ft)

N type connector

Clevis

Cable hoist

When the cable is in position, fasten the grip handle to a tower member and remove the hoist line.

Page 329: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Installing the IF and ground cables

phn-2779_001v000 (Jul 2012) 5-55

Installing and grounding the main IF cable

Perform this procedure to install and ground the IF cable from the top LPU to the building entry point (Figure 70). The IF cable must be grounded at the points specified in Protection requirements for a mast or tower installation on page 2-10.

Figure 70 IF cable grounding on a mast or tower

Page 330: Cambium network ptp 810 series 01 00 user guide

Installing the IF and ground cables Chapter 5: Installation

5-56 phn-2779_001v000 (Jul 2012)

To install and ground the main IF cable, proceed as follows:

1 Attach the N type connector at the top end of the main IF cable to the SURGE port of the top LPU.

2 Protect the N type connectors on the LPU from the weather by applying self-amalgamating and PVC tape, as described in Weatherproofing an N type connector on page 5-47.

3 Lay the main IF cable as far as the building entry point, ensuring there is enough length to extend through the wall of the building to the bottom LPU.

4 Attach the main IF cable to the supporting structure using the cable ties provided.

5 Ground the IF cable at the points specified in Protection requirements for a mast or tower installation on page 2-10.

Follow the procedure Making an IF cable ground point on page 5-57.

Page 331: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Installing the IF and ground cables

phn-2779_001v000 (Jul 2012) 5-57

Making an IF cable ground point

Perform this task to connect the screen of the IF cable to the metal of the supporting structure using a cable grounding kit.

The cable grounding kit for 1/4” and 3/8” cable (Figure 26) contains the following components:

• 1 x grounding cable with grounding 2 hole lug fitted (M10)

• 1 x self Amalgamating tape

• 1 x PVC tape

• 3 x tie wraps

• 2 x bolt, washer and nut

Install ground cables without drip loops and pointing down towards the ground, otherwise they may not be effective.

To ground the IF cable to a metal structure using the Cambium grounding kit (part number 01010419001), proceed as follows:

1 Remove 60 mm (2.5 inches) of the IF cable outer jacket:

Page 332: Cambium network ptp 810 series 01 00 user guide

Installing the IF and ground cables Chapter 5: Installation

5-58 phn-2779_001v000 (Jul 2012)

2 Cut 38 mm (1.5 inches) of rubber tape (self amalgamating) and fit to the ground cable lug. Wrap the tape completely around the lug and cable:

3 Fold the ground wire strap around the drop cable screen and fit cable ties.

4 Tighten the cable ties with pliers.

Cut the surplus from the cable ties.

Page 333: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Installing the IF and ground cables

phn-2779_001v000 (Jul 2012) 5-59

5 Cut a 38 mm (1.5 inches) section of self-amalgamating tape and fit to the ground cable lug. Wrap the self-amalgamating tape completely around the lug and cable.

6 Use the remainder of the self-amalgamating tape to wrap the complete assembly. Press the tape edges together so that there are no gaps:

Page 334: Cambium network ptp 810 series 01 00 user guide

Installing the IF and ground cables Chapter 5: Installation

5-60 phn-2779_001v000 (Jul 2012)

7 Wrap a layer of PVC tape from bottom to top, starting from 25 mm (1 inch) below and finishing 25 mm (1 inch) above the edge of the self-amalgamating tape, over lapping at half width.

8 Repeat with a further four layers of PVC tape, always overlapping at half width. Wrap the layers in alternate directions:

Second layer: top to bottom.

Third layer: bottom to top.

Fourth layer: top to bottom.

Fifth layer: bottom to top.

The edges of each layer should be 25mm (1 inch) above (A) and 25 mm (1 inch) below (B) the previous layer.

9 Prepare the metal grounding point of the supporting structure to provide a good electrical contact with the grounding cable clamp. Remove paint, grease or dirt, if present. Apply anti-oxidant compound liberally between the two metals.

Page 335: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Installing the IF and ground cables

phn-2779_001v000 (Jul 2012) 5-61

10 Clamp the bottom lug of the grounding cable to the supporting structure using site approved methods.

Use a two-hole lug secured with fasteners in both holes. This provides better protection than a single-hole lug.

Installing and grounding the IF cable at building entry

Perform this procedure to install and ground the main IF cable at the building (or cabinet) entry point (Figure 71).

Figure 71 Grounding at building entry

External Ground Bar (EGB)

Lightning Protection Unit (LPU)

Master Ground Bar (MGB)

Ground cable

IF cable

To MMU

Ground ring

Page 336: Cambium network ptp 810 series 01 00 user guide

Installing the IF and ground cables Chapter 5: Installation

5-62 phn-2779_001v000 (Jul 2012)

To connect the IF cable to the bottom LPU, proceed as follows:

1 Make an entry point into the building and run the main IF cable into the building.

2 Ground the IF cable to the external ground bar outside the building entry point, as described in Making an IF cable ground point on page 5-57.

3 Install the bottom LPU inside the building entry point.

4 Ground the bottom LPU to the master ground bar.

5 Connect the main IF cable (from the ODU) to the SURGE port of the bottom LPU.

6 Connect the LPU-MMU IF cable to the EQUIPMENT port of the bottom LPU and run it to the location of the MMU.

Page 337: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Testing the ODU and IF cable

phn-2779_001v000 (Jul 2012) 5-63

Testing the ODU and IF cable

This section describes how to perform pre-power tests on the ODU, LPUs and the IF cable.

Recommended pre-power tests

After installation of the ODU, LPUs and the IF cable, but before connecting and applying power to the MMU, perform the following tests:

• Cable loss with ODU disconnected:

Confirm that the total cable loss, including loss from the LPUs, is within acceptable limits.

• Cable loss with the ODU connected:

Confirm that the cable contains no short circuit or open circuit.

• Distance to fault (DTF) return loss with the ODU connected:

Confirm the position of the LPUs in the cable run and confirm that there are no other points of discontinuity in the cable. To detect any degradation over time, compare a current plot to a previously recorded plot, if available.

Test equipment

Use an RF cable analyzer such as an Anritsu ‘Site Master’ to confirm that the installed cable between the ODU and the MMU has the correct loss and does not have any short or open circuits. If the cable is faulty, use this equipment to identify the location of a fault in the cable.

Figure 72 is an example of a cable analyzer that is suitable for performing the tests described in this section.

Page 338: Cambium network ptp 810 series 01 00 user guide

Testing the ODU and IF cable Chapter 5: Installation

5-64 phn-2779_001v000 (Jul 2012)

Figure 72 Example of a cable analyzer

Test preparation

Set up the equipment to perform the pre-power tests. Figure 73 is an example to show how this is done. In this example, there is a short length of cable from the analyzer (in place of the MMU) to the first LPU, a length of cable ‘y’ from the first LPU to the second LPU (at the top of the tower) and a short length of cable from the second LPU to the ODU (0.7m long supplied in the accessory kit).

Figure 73 Example of the cable test

Perform these tests in conjunction with the test equipment manufacturer’s instructions.

Page 339: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Testing the ODU and IF cable

phn-2779_001v000 (Jul 2012) 5-65

To prepare for pre-power testing, proceed as follows:

1 Connect the analyzer to the first LPU (Figure 73).

2 Connect the first LPU to the second (Figure 73).

3 Check that the second LPU is disconnected from the cable that leads to the ODU (Figure 73) (the second LPU and ODU are reconnected during testing).

4 Power on the analyzer.

When these preparations are complete, perform the following tests:

• Testing cable loss on page 5-65.

• Measuring distance to fault on page 5-68.

Testing cable loss

The purpose of this test is to ensure that the total cable loss is within acceptable limits.

Before performing this test, ensure that the test equipment is set up as described in Test preparation on page 5-64.

To measure cable loss, proceed as follows:

1 Select the ‘cable loss-one port’ mode of the cable analyzer (Figure 72).

2 Set the frequency of measurement to:

F1 = 100 MHz

F2 = 400 MHz.

3 Calibrate the instrument for the selected frequencies, using the correct calibration kit.

4 Before connecting the ODU, obtain a plot of cable loss and check that it is within the expected limits for the given cable length. Compare it to examples of good installations (Figure 74).

5 Connect the ODU.

6 Observe the effect of the ODU connection on the plot of cable loss.

Compare it to examples of good installations (Figure 75).

If there is little or no change to the plot when the ODU is connected, it indicates a short or open circuit on the cable.

7 Keep a copy of the cable loss plots so that they can be compared with subsequent plots to determine if there is any degradation with time.

Page 340: Cambium network ptp 810 series 01 00 user guide

Testing the ODU and IF cable Chapter 5: Installation

5-66 phn-2779_001v000 (Jul 2012)

Cable loss example using a 14 meter cable

This example is for a cable run consisting of the following:

• 0.7m cable from the test equipment to the first LPU.

• The first LPU.

• 14m of cable between the two LPUs (length ‘y’ in Figure 73).

• The second (mast mounted) LPU.

• 0.7m of cable from the LPU to ODU.

When testing cable loss, compare the ‘before’ and ‘after’ plots of cable loss:

• Figure 74 is a plot of cable loss taken before the ODU was connected. The plot shows an average cable loss of 1.57 dB. For a cable length of approximately 16m (14m +0.7m + 0.7m) with two LPUs, the table result is 1.42 dB, which is within the expected tolerance of +/- 10%.

• Figure 75 is a plot of cable loss taken after the ODU was connected.

Figure 74 Cable loss plot for a 14 meter cable with no ODU

Page 341: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Testing the ODU and IF cable

phn-2779_001v000 (Jul 2012) 5-67

Figure 75 Cable loss plot for a 14 meter cable with ODU connected

Expected cable loss

Table 224 quotes the expected cable loss for given cable lengths when the ODU is not connected. All loss figures have a tolerance of plus or minus 10%, for example, 1.76 dB means that the loss is expected to be between 1.58 and 1.94 dB.

Table 224 Expected cable loss when ODU is not connected

Cable Length (meters)

Cable Loss (+/- 10%) at 350 MHz (dB)

Cable Loss (+/- 10%) with two Lightning Protection Units fitted, at 350 MHz (dB)

1 0.08 0.3

2 0.15 0.37

3 0.23 0.45

4 0.31 0.53

5 0.39 0.61

6 0.46 0.68

7 0.54 0.76

Page 342: Cambium network ptp 810 series 01 00 user guide

Testing the ODU and IF cable Chapter 5: Installation

5-68 phn-2779_001v000 (Jul 2012)

Cable Length (meters)

Cable Loss (+/- 10%) at 350 MHz (dB)

Cable Loss (+/- 10%) with two Lightning Protection Units fitted, at 350 MHz (dB)

8 0.62 0.84

9 0.69 0.91

10 0.77 0.99

20 1.54 1.76

30 2.31 2.53

40 3.08 3.3

50 3.85 4.1

100 7.7 7.92

Measuring distance to fault

The distance to fault (DTF) test is used as a means of characterizing the cable installation, but can also be used to determine the location of a fault in an installation.

Before performing this test, ensure that the test equipment is set up as described in Test preparation on page 5-64.

To measure distance to fault, proceed as follows:

1 Select the ‘DTF-return loss’ mode of the cable analyzer (Figure 72).

2 Select ‘DTF Aid’.

3 Use the up/down key to select and set the following:

Cable type - select LMR400 (similar to CNT-400) or LMR600 (similar to CNT-600) as appropriate.

F2 - select the highest frequency possible for the greatest resolution, 1600 MHz.

D1 and D2 - set as appropriate for the specific installation.

4 Recalibrate the instrument.

5 Before connecting the ODU, obtain a plot of DTF loss. Compare it to an example of a good installation (Figure 76).

6 Connect the ODU.

7 Observe the effect of the ODU connection on the DTF plot. Compare it to an example of a good installation (Figure 77).

Page 343: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Testing the ODU and IF cable

phn-2779_001v000 (Jul 2012) 5-69

8 Keep a copy of the DTF plots so that they can be compared with subsequent plots to determine if there is any degradation with time.

The absolute readings of DTF should be read with care, as many different variables affect both distance and amplitude accuracy.

DTF return loss example

This example shows typical DTF return loss in a good installation. The distances from the test equipment to first LPU (marker M2), and then the second LPU (marker M3) are clearly shown. The cable between them shows no discontinuity. There are two plots:

• Figure 76 is a plot of DTF return loss before the ODU is connected. The final peak (marker M1) is the position of the cable open circuit.

• Figure 77 is a plot of DTF return loss after the ODU is connected. The final peak remains in the same position but is now reduced in amplitude because less signal is reflected, as a consequence of the better match of the ODU.

Figure 76 DTF plot for a 17 meter cable with no ODU

-60

-50

-40

-30

-20

-10

0

0.0 2.5 5.0 7.5 10.0 12.5 15.0 17.5 20.0 22.5 25.0

M1M2 M3

Distance-to-faultLPU+17M

Model: S311D Serial #: 00936036 Prop.Vel:0.850Date: 11/10/2009 Time: 04:49:26 Ins.Loss:0.135dB/mStd: --- Channel: N/AResolution: 517 CAL:ON(COAX) CW: OFF

dB

Distance (0.0 - 25.0 Meter)

M1: -5.03 dB @ 18.56 m M2: -13.11 dB @ .63 m M3: -17.41 dB @ 17.83 m

Page 344: Cambium network ptp 810 series 01 00 user guide

Testing the ODU and IF cable Chapter 5: Installation

5-70 phn-2779_001v000 (Jul 2012)

Figure 77 DTF plot for a 17 meter cable with ODU connected

-60

-50

-40

-30

-20

-10

0

0.0 2.5 5.0 7.5 10.0 12.5 15.0 17.5 20.0 22.5 25.0

M1M2 M3

Distance-to-faultODU+LPU+17M

Model: S311D Serial #: 00936036 Prop.Vel:0.850Date: 11/10/2009 Time: 04:50:58 Ins.Loss:0.135dB/mStd: --- Channel: N/AResolution: 517 CAL:ON(COAX) CW: OFF

dB

Distance (0.0 - 25.0 Meter)

M1: -16.41 dB @ 18.70 m M2: -13.08 dB @ .63 m M3: -17.50 dB @ 17.83 m

Page 345: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Installing the MMU

phn-2779_001v000 (Jul 2012) 5-71

Installing the MMU

This section describes how to mount the MMU in the building or cabinet, and to connect it to ground, power supply and PC.

To minimise radiated emissions, use screened Ethernet cable for all copper connections from the MMU Ethernet ports. This includes the Data port connection to any network switch and the Management port to any network switch.

Mounting the MMU

The MMU is designed to fit into 19" cabinets and equipment frames. The MMU kit contains the MMU, two MMU rack mounting brackets, and power connector.

To prevent the MMU from overheating, air must be able to pass freely over the chassis, especially the front panel of the MMU (the end where the connectors are located).

To rack mount the MMU in a 19 inch cabinet rack, use the supplied mounting brackets to secure the chassis of the MMU to the rack cabinet (Figure 78). If mounting in an equipment frame, locate the mounting brackets in the middle of the MMU. To maintain good airflow and cooling, install the MMU in a slot that has blank spaces above and below the unit.

Figure 78 MMU with rack mounting bracket (front mounting option shown)

Page 346: Cambium network ptp 810 series 01 00 user guide

Installing the MMU Chapter 5: Installation

5-72 phn-2779_001v000 (Jul 2012)

To avoid damaging the RF cable, route it in such a way that the minimum bend radius for the selected cable is always exceeded.

If cables are laid in an air-handling cavity, they must be Plenum rated.

A right angle IF cable connector (Cambium part number N000081L006A) can make it easier to install the MMU in the rack.

Grounding the MMU

Ground the MMU to a rack ground bar, master ground bar or other suitable ground using a minimum cable cross section of 10 mm2 (6AWG) (Figure 37). It is a condition of the safety approval that the unit is grounded. Attach the ground cable to either one of the two MMU ground connectors on the front panel (Figure 79).

Figure 79 MMU ground connector

Page 347: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Installing the MMU

phn-2779_001v000 (Jul 2012) 5-73

Connecting the MMU to the IF cable

For links requiring a dual modem MMU, repeat this procedure for the second ODU and MMU modem module.

Connect the IF cable (from the bottom LPU) to the MMU modem module. The example (Figure 80) shows the N-Type to TNC Adapter.

Figure 80 MMU IF cable connector (non-standard connector shown)

Connecting the MMU power supply

Use of a power supply with an inappropriate ground reference may cause damage to the MMU and/or the supply. The MMU is designed to operate normally with a reversed polarity with a floating -48 V dc power-supply. If the -48 V dc power-supply is ground referenced (not floating), then two problems can occur if the ground reference is connected to the -48 V dc input of the MMU power module:

1) If the MMU is properly grounded, then a power-supply short will occur. Damage to the rest of the MMU is unlikely, but the MMU's internal power supply module could be damaged. This would require replacement of the power supply module.

2) If the MMU is not properly grounded and the ODU is grounded, then a short or high-current path is likely. The high- current path scenario could affect components on the MMU modem module and also cause damage to the MMU power supply module.

Page 348: Cambium network ptp 810 series 01 00 user guide

Installing the MMU Chapter 5: Installation

5-74 phn-2779_001v000 (Jul 2012)

Power supply redundancy

For a single modem MMU sourcing power to a single ODU, connect the MMU power supply module to a -48 V dc power supply capable of supplying a maximum of 2.1 amps. For either a dual modem MMU or a single modem MMU with a redundant power supply module, connect a power cable to both of the MMU power supply modules. If one of the power supply modules fails on a dual modem MMU, the remaining power supply module must be capable of potentially supplying power to the MMU and two active ODUs. This requires a −48 V dc power supply capable of supplying a maximum of 3.2 amps.

Preparing the MMU power cable

Assemble the MMU power cable, ensuring that the following requirements are met:

• If the power cable is under 3 meters (10 ft) in length and supplies -48 V dc, use wire size 16 AWG.

• Use a power cable that is long enough to avoid tension in the cable and provides a service loop for connection, but is not too long.

• To reduce tension on the MMU DC power connector, use stranded wire, not a solid conductor.

• Using the supplied power cable connector provided with the MMU, connect pin 2 (labeled -V) to the power supply terminal supplying -48V dc, and connect pin 1 (labeled RET) to the power supply return (Figure 81).

This connector has screw clamp terminals that accommodate 24 AWG to 12 AWG wire.

• At the opposite end of the MMU power cable, use a termination that is appropriate for the power supply being used.

Connect the MMU to its power cable (Figure 82).

Figure 81 MMU DC power cable connector

Page 349: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Installing the MMU

phn-2779_001v000 (Jul 2012) 5-75

Figure 82 MMU with power cable connected

Powering up the MMU

To connect the MMU to its power supply, proceed as follows:

1 Connect the MMU power cable to the -48 V dc power supply.

Place the voltmeter probes on the unconnected MMU end of the power cable, with the positive voltmeter probe on pin 2 (-V) of the cable connector and the negative probe on pin 1 (RET) (Figure 81). The connector terminal screw heads may be used as convenient monitor points.

2 Turn the -48 V dc supply on.

Verify that the digital voltmeter reads -48 V dc when monitoring the cable points specified above.

To achieve this reading, adjust the power supply output voltage or change the connections at the power supply.

3 Turn the -48 V dc supply off.

Page 350: Cambium network ptp 810 series 01 00 user guide

Installing the MMU Chapter 5: Installation

5-76 phn-2779_001v000 (Jul 2012)

4 Plug the MMU power cable into the MMU front panel DC power connector (DC Input).

Place the voltmeter probes on the cable connector terminal screw heads as per Step 1 above (Figure 81).

Before applying power, ensure that the antenna is directed safely. As the MMU does not have a power on/off switch, the digital radio begins transmitting as soon as power is applied. There can be up to 320 mW of RF power present at the antenna port.

5 Turn the -48 V dc power supply on.

Verify that the reading on the digital voltmeter is as specified in Step 2 above.

Page 351: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Preparing network connections (1+0 and 2+0 links)

phn-2779_001v000 (Jul 2012) 5-77

Preparing network connections (1+0 and 2+0 links)

This section describes how to prepare the cables to connect the MMU to router ports, switch ports or other equipment in the customer and (optionally) management networks. It applies only to unprotected ends (1+0 and 2+0 links).

When installing a 2+0 link, prepare separate network connections for the link ‘A’ and the link ‘B’ MMUs.

The MMU is not normally connected to the network equipment until antenna alignment is complete (as described in Task 13: Connecting link to the network on page 6-94).

Choose from the following installation procedures:

• Installing an Ethernet data interface on page 5-78

• Installing a fiber data interface on page 5-79

• Installing a management interface on page 5-82

• Installing an E1/T1 interface on page 5-83

• Installing an XPIC interface on page 5-85

Page 352: Cambium network ptp 810 series 01 00 user guide

Preparing network connections (1+0 and 2+0 links) Chapter 5: Installation

5-78 phn-2779_001v000 (Jul 2012)

Installing an Ethernet data interface

To provide an Ethernet data interface, connect USER 10/100 port 1 or 2 (Master I/O module) to the network as shown in Figure 83. For pinout connections, refer to Table 81.

Figure 83 Copper data interface connections

Page 353: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Preparing network connections (1+0 and 2+0 links)

phn-2779_001v000 (Jul 2012) 5-79

Installing a fiber data interface

To provide a fiber data interface, connect the MMU Fiber SFP (GigE module) port to the network as shown in Figure 84. For fiber connections, refer to Table 83.

The SFP interface is only available if the MMU has a GigE Master I/O module.

Figure 84 Fiber data interface connections

Tx Rx

Tx Rx

SFP module in MMU

SFP module in Ethernet switch

MMU Tx port to Ethernet switch Rx port

MMU Rx port to Ethernet switch Tx port

Page 354: Cambium network ptp 810 series 01 00 user guide

Preparing network connections (1+0 and 2+0 links) Chapter 5: Installation

5-80 phn-2779_001v000 (Jul 2012)

Connecting fiber cables to the MMU

To connect fiber cables to the MMU, proceed as follows:

1 Insert an SFP module into the SFP port of the GigE Master I/O module with the PCB connector down and label up.

2 Remove the protective caps from the LC connectors.

Page 355: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Preparing network connections (1+0 and 2+0 links)

phn-2779_001v000 (Jul 2012) 5-81

3 Plug the LC connectors into the SFP module, ensuring they snap home.

Page 356: Cambium network ptp 810 series 01 00 user guide

Preparing network connections (1+0 and 2+0 links) Chapter 5: Installation

5-82 phn-2779_001v000 (Jul 2012)

Installing a management interface

To provide a management interface, connect NMS 10/100 port 1 or 2 (Control module) to the network as shown in Figure 85. For pinout connections, refer to Table 84.

At the edge of a network, if the management network equipment is inaccessible, leave the MMU management port disconnected.

Figure 85 Management interface connections

MMU Control ModuleNMS 10/100 port 1 or 2

Ethernet switch port

RJ48 plug

Cat5e cable

Page 357: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Preparing network connections (1+0 and 2+0 links)

phn-2779_001v000 (Jul 2012) 5-83

Installing an E1/T1 interface

To provide an E1/T1 (RJ-48C) interface, connect E1/T1 port 1 or 2 (Master I/O module) to the telecommunications network as shown in Figure 86. For pinout connections, refer to Table 86.

Figure 86 E1/T1 interface (RJ-48C)

Page 358: Cambium network ptp 810 series 01 00 user guide

Preparing network connections (1+0 and 2+0 links) Chapter 5: Installation

5-84 phn-2779_001v000 (Jul 2012)

Alternatively, To provide an E1/T1 (molex 60-pin) interface containing 14 E1/T1 connections, E1/T1 port 3-16 (Master I/O module) to the telecommunications network as shown in Figure 87. For pinout connections, refer to Table 87.

The molex 60-pin interface is only available if the MMU has a Standard Master I/O module or an Expansion I/O module.

Figure 87 E1/T1 interface (molex 60-pin)

Page 359: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Preparing network connections (1+0 and 2+0 links)

phn-2779_001v000 (Jul 2012) 5-85

Installing an XPIC interface

To provide an XPIC link, use an XPIC cable (Cambium part number N000081L004A) to connect the two modem modules of a dual modem MMU together using the XPIC Interface ports located on each modem module (Figure 88).

Figure 88 XPIC interface

Page 360: Cambium network ptp 810 series 01 00 user guide

Preparing network connections (1+0 and 2+0 links) Chapter 5: Installation

5-86 phn-2779_001v000 (Jul 2012)

Page 361: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide

phn-2779_001v000 (Jul 2012) 6-1

Chapter 6: Configuration and alignment

This chapter describes how to configure a PTP 810 link and align its antennas.

Observe the precautions in Preparing for configuration and alignment on page 6-2.

Configure the two units by performing the following tasks:

• Task 1: Connecting to the unit on page 6-3

• Task 2: Configuring IP and Ethernet interfaces on page 6-14

• Task 3: Configuring wireless interface on page 6-24

• Task 4: Configuring E1/T1 interfaces on page 6-38

• Task 5: Configuring data orderwire on page 6-48

• Task 6: Configuring protection on page 6-50

• Task 7: Setting up SNMP agent on page 6-54

• Task 8: Configuring alarms and messages on page 6-57

• Task 9: Configuring syslog on page 6-62

When all equipment has been installed at both link ends, perform the following tasks:

• Task 10: Configuring quality of service on page 6-63

• Task 11: Configuring VLAN on page 6-73

• Task 12: LACP configuration on page 6-92

• Task 13: Connecting link to the network on page 6-94

• Task 14: Aligning antennas on page 6-98

• Task 15: Reviewing configuration and performance on page 6-104

Page 362: Cambium network ptp 810 series 01 00 user guide

Preparing for configuration and alignment Chapter 6: Configuration and alignment

6-2 phn-2779_001v000 (Jul 2012)

Preparing for configuration and alignment

Before proceeding with unit configuration and antenna alignment, perform the checks described in this section.

Safety precautions during configuration and alignment

All national and local safety standards must be followed while configuring the units and aligning the antennas.

Ensure that personnel are not exposed to unsafe levels of RF energy. The units start to radiate as soon as they are powered up. Respect the safety standards defined in Radiation hazard assessment on page 4-83, in particular the minimum separation distances.

Never work in front of the antenna when the MMU is powered.

Always power down the MMU before connecting or disconnecting the drop cable from the MMU, ODU or LPU.

Regulatory compliance during configuration and alignment

When configuring the units and aligning the antennas, follow all applicable radio regulations. For more information, refer to Electromagnetic compliance on page 4-79.

Selecting configuration options

Use the installation report to determine which configuration options are required. Refer to Link planning on page 2-2.

Purchasing license key

Before starting configuration of the MMU, purchase authorization key(s) for data throughput capacity or XPIC capability (if required). Refer to Ordering capacity upgrades and XPIC capability on page 2-40.

Page 363: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 1: Connecting to the unit

phn-2779_001v000 (Jul 2012) 6-3

Task 1: Connecting to the unit

To connect the MMU to a PC for the purpose of initial configuration, perform the following procedures:

• Configuring the management PC on page 6-3

• Updating the ARP table on page 6-6

• Connecting to the PC and powering up on page 6-7

To log into the MMU for configuration purposes, use one of the following alternative methods:

• Logging into the web interface on page 6-7

• Logging into the CLI interface on page 6-9

The remaining tasks in this chapter describe how to configure the MMU using the web interface only.

Configuring the management PC

To configure the local management PC to communicate with the PTP 810, proceed as follows:

Page 364: Cambium network ptp 810 series 01 00 user guide

Task 1: Connecting to the unit Chapter 6: Configuration and alignment

6-4 phn-2779_001v000 (Jul 2012)

1 Display the Local Area Connection Properties dialog.

The path to this dialog depends on Windows version and PC configuration, for example select: Control Panel, Network Connections, Local Area Connection, Properties.

Page 365: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 1: Connecting to the unit

phn-2779_001v000 (Jul 2012) 6-5

2 Select Internet Protocol (TCP/IP) and click on Properties. The Internet Protocol (TCP/IP) Properties dialog is displayed:

3 Enter an IP address that is valid for the 192.168.0.X network, avoiding:

192.168.0.0 and 192.168.0.1

A good example is 192.168.0.3 as shown.

4 Enter a subnet mask of 255.255.255.0.

Leave the default gateway blank.

5 Click on OK.

Page 366: Cambium network ptp 810 series 01 00 user guide

Task 1: Connecting to the unit Chapter 6: Configuration and alignment

6-6 phn-2779_001v000 (Jul 2012)

6 If the network adaptor supports advanced properties then configure Ethernet Speed and Duplex for automatic negotiation. One example, based on a Broadcom™ adaptor, is shown:

Updating the ARP table

All PTP 810 units are supplied by Cambium with the same default IP address. When the management PC is connected to a PTP 810 unit, it creates an association between the default IP address (192.168.0.1) and the MAC address of the PTP 810.

If two or more PTP 810 units are being configured, then remove this association after each unit has been configured. To remove the association between IP address and MAC address in the ARP table of the management PC: open a command prompt window on the PC and enter this command:

arp –d 192.168.0.1

When this address is next used, the PC will connect it with the MAC address of the unit being configured and update the ARP table with the new association.

Page 367: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 1: Connecting to the unit

phn-2779_001v000 (Jul 2012) 6-7

Connecting to the PC and powering up

To connect the MMU to the PC and power it up, proceed as follows:

1 Connect the MMU to an ODU for a single modem MMU or to two ODUs for a dual modem MMU.

2 Connect the PC Ethernet port to the NMS 1 or NMS 2 port of the MMU using a straight-through or crossed Cat5e cable.

3 Switch on the MMU power supply.

4 Wait until the MMU Control Module Status LED shows green steady. This normally occurs within 3 minutes from applying power.

Logging into the web interface

If the management PC is connected to another LAN it may need to be configured to not use proxy servers for this IP address.

To log into the MMU web interface, proceed as follows:

1 Start the web browser from the management PC. Use either Internet Explorer version 5.5 (or above) or Mozilla Firefox (latest version). The web interface also requires the use of Sun Java Runtime Environment 5.0 (or above).

2 Type the default IP address of the unit into the address bar: 192.168.0.1 and press ENTER.

A popup window prompts for user name and password entry:

3 Enter default user name ‘administrator’ and password (Table 225), then select OK.

Page 368: Cambium network ptp 810 series 01 00 user guide

Task 1: Connecting to the unit Chapter 6: Configuration and alignment

6-8 phn-2779_001v000 (Jul 2012)

4 Upon successful authentication, the Starting Information page is displayed (Figure 89).

Table 225 Default usernames and passwords

User Level Username Password

Monitor monitor monitor

Operator operator col1ma

Administrator administrator d1scovery

Figure 89 Starting Information page

Page 369: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 1: Connecting to the unit

phn-2779_001v000 (Jul 2012) 6-9

Logging into the CLI interface

View CLI pages using a window of 25 rows by 80 columns (25 x 80). A window of less than 25 x 80 will have incomplete content.

The CLI provides a text based interface for configuring and monitoring the terminal. To access the CLI, use one of the following methods: Ethernet interface, Windows standard telnet client, or RS232 connection via a serial terminal.

Ethernet interface

To access the CLI via an Ethernet interface, proceed as follows:

1 Telnet / SSH to the terminal (using IP address of the terminal).

2 Enter a user name and password at the login prompt.

Windows standard telnet client

To access the CLI via a Windows standard telnet client, proceed as follows:

1 Select menu option Start, Run.

2 In the Run window type: telnet [IP address]

3 Enter a user name and password at the login prompt.

RS232 connection via a serial terminal

To establish an RS232 connection using a serial terminal, proceed as follows:

1 Connect the Serial/Alarm port on the MMU to a COM port on the computer.

2 Start a hyperterminal session and select the following COM port settings:

Bits per second: 38400 Data bit: 8 Parity: None Stop bits: 1 Flow Control: None

Page 370: Cambium network ptp 810 series 01 00 user guide

Task 1: Connecting to the unit Chapter 6: Configuration and alignment

6-10 phn-2779_001v000 (Jul 2012)

3 For optimum viewing, use the following terminal and ASCII settings:

Emulation: VT 100 Line Delay: 50 ms Character Delay: 10 ms Text Wrap: On

4 Power on the MMU. Once the boot process is complete, press the keyboard return key to receive a login prompt.

5 Enter a user name and password at the login prompt.

Successful authentication

Upon successful authentication, the CLI General Information page is displayed (Figure 90). Switch to the ‘Main Menu’ screen by pressing the M-key. Use the Main Menu to navigate through various interface screens.

Figure 90 CLI General Information page

Menu pages

Use the menu screens to navigate between functions. They display a list of navigation choices. Each choice is listed with a character encased within [ ] braces, or ‘hotkey’. Press the ‘hotkey’ to switch to the corresponding page. For example, in the CLI Main Menu (

Figure 91), enter ‘a’ / ‘A’, to switch to the General Information page.

Page 371: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 1: Connecting to the unit

phn-2779_001v000 (Jul 2012) 6-11

Figure 91 CLI Main Menu page

Further references to ‘hotkey’ in this document will refer to the character encapsulated in [ ] brackets for the individual parameter.

Configurable pages

Configurable pages are used to set various parameters. For example, Figure 92 shows the Date and Time page.

Page 372: Cambium network ptp 810 series 01 00 user guide

Task 1: Connecting to the unit Chapter 6: Configuration and alignment

6-12 phn-2779_001v000 (Jul 2012)

Figure 92 Example of a configurable CLI page

Parameters are listed with their values and a ‘hotkey’. Press the ‘hotkey’ to configure the corresponding parameter. For example, enter ‘a’ / ‘A’, to edit Date, then press ‘Enter’ key. Some parameters may have a set list of values. For example, the SNTP Server Enable parameter has two values: Enabled and Disable. To edit this type of parameter, press the corresponding ‘hotkey’ (in this case ‘D’), then press the ‘Space Bar’-key, to scroll through different values. Once the desired value is displayed, press the ‘Enter’ key. If the parameter is displayed without a ‘hotkey’, it indicates a read-only parameter.

All the CLI pages display the following message types:

• Navigation Message: Help message about possible navigation from the page. This is displayed at top left and top right of the page.

• Screen Message: Help message about the page. This is displayed at the 24th row.

• Access Message: Help message about how to access parameters of the page. This is displayed at the 25

th (last) row.

Page 373: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 1: Connecting to the unit

phn-2779_001v000 (Jul 2012) 6-13

In the CLI, there are two different types of parameter updates. Some parameters are updated individually and others are updated as a group:

• To perform an individual update: edit the parameter value and press the ENTER key. If update is successful, the message Updated Successfully is displayed. If the update fails, a failure message is displayed.

• To perform a group update: edit the parameter value, press the ENTER key and press the character specified for ‘Update’. If update is successful, the message Updated Successfully is displayed. If the update fails, a failure message is displayed.

Page 374: Cambium network ptp 810 series 01 00 user guide

Task 2: Configuring IP and Ethernet interfaces Chapter 6: Configuration and alignment

6-14 phn-2779_001v000 (Jul 2012)

Task 2: Configuring IP and Ethernet interfaces

This task consists of the following procedures:

• Configuring the IP interface on page 6-14

• Reconnecting to the management PC on page 6-15

• Configuring Serial Port on page 6-15

• Configuring Ethernet payload on page 6-16

• Configuring Ethernet network management on page 6-21

Configuring the IP interface

The IP interface allows users to connect to the PTP 810 web interface, either from a locally connected computer or from a management network.

To configure the IP interface, select menu option Administration, Network Configuration, General. The General Network Configuration page is displayed (Figure 93). Update the attributes (Table 226) and select Update.

To revert to previous values, select Reset.

Figure 93 General Network Configuration page

Page 375: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 2: Configuring IP and Ethernet interfaces

phn-2779_001v000 (Jul 2012) 6-15

Table 226 General Network Configuration attributes

Attribute Meaning

IP Address The IP address of the MMU.

IP Netmask The appropriate netmask depending on the class of the network.

IP Gateway The gateway IP Address for the subnet. This should be on the same subnet as the IP Address of the MMU.

Ethernet Address The MAC or Hardware address of the terminal.

DHCP Client ‘Enabled’ means that network parameters are obtained dynamically from a DHCP server. The other parameters on the page cannot be modified when DHCP is enabled.

Reconnecting to the management PC

If the IP Address, IP Netmask and IP Gateway addresses of the unit have been updated to meet network requirements, then reconfigure the local management PC to use an IP address that is valid for the network. Refer to Configuring the management PC on page 6-3.

When the IP address of the unit has been reconfigured, log in using the new IP address. Refer to Logging into the web interface on page 6-7.

Access to the MMU can be recovered by restoring system defaults as described in Restoring system defaults on page 7-54.

Configuring Serial Port

A serial port is provided for basic control and provisioning of the MMU prior to establishing an Ethernet NMS connection. The IP address of the MMU can be read or set from this port. The serial port connector terminates in a high-density DB-15 connector. This connector is shared with the alarm interface.

To configure the serial port, select menu option Administration, Serial Configuration. The Serial Configuration page is displayed (Figure 94). Select a suitable Data Baud Rate for the selected device. The default is 38,400 kbps (N,8,1). Select Update.

To revert to previous value, select Reset.

Page 376: Cambium network ptp 810 series 01 00 user guide

Task 2: Configuring IP and Ethernet interfaces Chapter 6: Configuration and alignment

6-16 phn-2779_001v000 (Jul 2012)

Figure 94 Serial Configuration page

Configuring Ethernet payload

To configure the Ethernet payload, select menu option Administration, Network Configuration, Ethernet Payload. The installed Master I/O module determines which Ethernet Payload page is displayed: Standard Master I/O module (Figure 95) or GigE Master I/O module (Figure 96), or GigE Master I/O module with an SFP module installed (Figure 97). Update the attributes (Table 227 and Table 228) and select Update.

To revert to previous values, select Reset.

Page 377: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 2: Configuring IP and Ethernet interfaces

phn-2779_001v000 (Jul 2012) 6-17

Figure 95 Ethernet Payload page for MMU Standard Master I/O module

Page 378: Cambium network ptp 810 series 01 00 user guide

Task 2: Configuring IP and Ethernet interfaces Chapter 6: Configuration and alignment

6-18 phn-2779_001v000 (Jul 2012)

Figure 96 Ethernet Payload page for MMU GigE Master I/O module

Page 379: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 2: Configuring IP and Ethernet interfaces

phn-2779_001v000 (Jul 2012) 6-19

Figure 97 Ethernet Payload page for MMU GigE Master I/O module with an SFP module

Page 380: Cambium network ptp 810 series 01 00 user guide

Task 2: Configuring IP and Ethernet interfaces Chapter 6: Configuration and alignment

6-20 phn-2779_001v000 (Jul 2012)

Table 227 Ethernet Payload attributes (Spanning Tree Configuration)

Attribute Meaning

Spanning Tree Mode Either ‘IEEE 802.1w (RSTP)’ or ‘Disabled’.

Bridge Priority Bridge priority in range 0 to 61440 (default 32768).

Max Age The maximum age in seconds in range 6 to 40 seconds (default 20 seconds).

Hello Time The time in range 1 to 10 seconds (default 2 seconds).

Forward Delay The delay in range 4 to 30 seconds (default 15 seconds).

Fast Hello Time Enables configuration of Hello Times between 600 and 900 milliseconds. Fast Hello Time is not interoperable with third party equipment such as switches and routers.

Priority The Ethernet priority for all ports and for the radio link(s).

Table 228 Ethernet Payload attributes (Ethernet Port Configuration)

Attribute Meaning

SFP Vendor Name Only available when an SFP module is installed.

Displays the SFP module vendor name.

SFP Link Type Only available when an SFP module is installed.

Displays the SFP module link type: Optical or Electrical.

Auto-Negotiation (*) Enable or Disable auto-negotiation.

Port Speed (*) Speed of the Ethernet port (Mbps):

Auto, 10 or 100

1000 (GigE Master I/O module only)

Port Duplex (*) Half / Full

Flow Control (*) The method of flow control employed:

Disable or Symmetric

Receive Only (GigE Master I/O module only)

Transmit Only (GigE Master I/O module only)

Master-Slave (*) Only available with GigE Master I/O module.

Slave, Master or Auto

Page 381: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 2: Configuring IP and Ethernet interfaces

phn-2779_001v000 (Jul 2012) 6-21

Attribute Meaning

Restart Auto-Negotiation (*)

Enable or Disable checkbox

Shutdown on Link Failure (*)

Enable or Disable checkbox

Ethernet Trunk Mode Only available when GigE Master I/O is installed and MMU is configured in East/East operational mode or 2+0 XPIC operational mode.

‘Disable’, ‘2+0 Trunk Port Aggregation’ or ‘4+0 Master’.

Select ‘2+0 Trunk Port Aggregation’ to enable Wireless Link Aggregation (see Wireless link aggregation on page 1-7).

Shutdown Radio Ports on Link Failure

Enable or Disable checkbox

Always enable Shutdown Radio Ports on Link Failure. This is a requirement for PTP 810.

(*) Set these attributes for: Ports 1-2 (Standard Master I/O module installed); Ports 1-4 (GigE Master I/O module installed); SFP (SFP module installed).

Configuring Ethernet network management

To configure the Ethernet NMS related parameters, select menu option Administration, Network Configuration, Ethernet NMS. The Ethernet NMS page is displayed (Figure 98). Update the attributes (Table 229 and Table 230) and select Update.

To revert to previous values, select Reset.

Page 382: Cambium network ptp 810 series 01 00 user guide

Task 2: Configuring IP and Ethernet interfaces Chapter 6: Configuration and alignment

6-22 phn-2779_001v000 (Jul 2012)

Figure 98 Ethernet NMS page

Page 383: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 2: Configuring IP and Ethernet interfaces

phn-2779_001v000 (Jul 2012) 6-23

Table 229 Ethernet NMS attributes (Spanning Tree Configuration)

Attribute Meaning

Spanning Tree Mode Either ‘IEEE 802.1w (RSTP)’ or ‘Disabled’.

Bridge Priority Bridge priority in range 0 to 61440 (default 32768).

Max Age The maximum age in seconds in range 6 to 40 seconds (default 20 seconds).

Hello Time The time in range 1 to 10 seconds (default 2 seconds).

Forward Delay The delay in range 4 to 30 seconds (default 15 seconds).

Priority The Ethernet priority for all ports and for the radio link(s).

Table 230 Ethernet NMS attributes (Ethernet Port Configuration)

Attribute Meaning

Auto-Negotiation (*) Enable or Disable auto-negotiation.

Port Speed (*) Speed of the Ethernet port (Mbps):

10 or 100

Port Duplex (*) Half / Full

Flow Control (*) The method of flow control employed:

Disable or Enable

Shutdown Radio Ports on Link Failure

Enable or Disable checkbox

(*) Set these attributes for both Ports (1-2).

Page 384: Cambium network ptp 810 series 01 00 user guide

Task 3: Configuring wireless interface Chapter 6: Configuration and alignment

6-24 phn-2779_001v000 (Jul 2012)

Task 3: Configuring wireless interface

The Link Configuration Wizard handles the important configuration settings that must be set to comply with the individual license conditions. The Link Configuration Wizard consists of the following procedures:

• Viewing the configuration summary on page 6-24

• Updating link configuration on page 6-25

• Configuring APC and coupler loss compensation on page 6-34

Viewing the configuration summary

To view the configuration summary, select menu option Link Configuration, Configuration Summary. The current Summary of Configurations page is displayed (Figure 99). Review the summary.

Figure 99 Summary of Configurations page

Page 385: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 3: Configuring wireless interface

phn-2779_001v000 (Jul 2012) 6-25

Updating link configuration

Before updating link configuration, check that all license details are available, including: maximum transmit power, antenna gain, transmit and receive frequencies, channel bandwidth, and modulation mode.

Select menu option Link Configuration, Radio Link, Link Configuration. This displays the first of the following series of Link Configuration pages:

• ODU Operational Mode

• IDU Operational Mode

• Payload Configuration

• ODU Tx Power Configuration

• ODU Channel Selection

• Adaptive Coding/Modulation

• Summary of Configurations (Redo or Update)

Use the last page in the series to choose whether to cancel (Redo) or apply (Update All) any change made in the first six Link Configuration pages.

In the Link Configuration pages, use only the Back and Next buttons to move to previous or next page. Do not use the browser back button.

If the selected parameters on the current page are not supported by the MMU terminal, an error message will be displayed on the next page. To correct the error, go back to the previous page and select a different value for that parameter.

ODU Operational Mode

The ODU Operational Mode page (Figure 100) is the first Link Configuration page (menu option Link Configuration, Radio Link, Link Configuration).

The ODU Operational Modes map to the PTP 810 link configurations as shown in Table 231. Update the ODU Operational Mode as required and select Next.

Table 231 also shows the number of sets of payload configuration and ODU parameters that are displayed for each ODU operational mode.

Page 386: Cambium network ptp 810 series 01 00 user guide

Task 3: Configuring wireless interface Chapter 6: Configuration and alignment

6-26 phn-2779_001v000 (Jul 2012)

Figure 100 ODU Operational Mode page

Table 231 Step 1: Link Configuration mapping to ODU Operational Modes

Link Configuration

ODU Operational Mode

Payload configuration parameters displayed

ODU parameters displayed

1+ 0 Standard One set One set

1+1 HSB Protected Non-Diversity One set One set

1+1 HSB SD Protected Non-Diversity One set One set

Dual 1+0 East/West Two sets Two sets

2+0 Co-Polar East/East Two sets Two sets

2+0 Cross-Polar East/East Two sets Two sets

2+0 XPIC 2+0 XPIC Two sets Two sets

Page 387: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 3: Configuring wireless interface

phn-2779_001v000 (Jul 2012) 6-27

IDU Operational Mode

The IDU Operational Mode page (Figure 101) is the second Link Configuration page (menu option Link Configuration, Radio Link, Link Configuration).

‘IDU Operational Mode’ means ‘MMU Operational Mode’.

The IDU Operational Mode drop-down menu displays the installed and authorized modes that are available for use. These modes are populated from the authorized entries in the Modes file. Update the IDU Operational Mode as required and select Next.

Figure 101 IDU Operational mode page

In the Modes file, the IDU Operational Modes have the following format:

[nnM] “-“ [xxxQ / QPSK] “-“ [E1 / T1] “-“ [X] ;

for example 56M-256Q-E1-X , where:

• Bandwidth (MHz): [nnM] = “7M”, “10M”, “14M”, “20M”, “28M”, “30M”, “40M”, “50M”, “56M”, or “80M”.

• Modulation: [xxxQ / QPSK] = “16Q”, “32Q”, “64Q”, “128Q”, “256Q” or “QPSK”.

• TDM Channel Type: [E1 / T1] = “E1”, “T1”.

• XPIC: [X] = “X” (appended to IDU Operational Mode parameter only if this is a mode used by XPIC).

Page 388: Cambium network ptp 810 series 01 00 user guide

Task 3: Configuring wireless interface Chapter 6: Configuration and alignment

6-28 phn-2779_001v000 (Jul 2012)

Payload Configuration

The Payload Configuration page (Figure 102) is the third Link Configuration page (menu option Link Configuration, Radio Link, Link Configuration).

The configured payload capacity parameter is used to determine the E1/T1, STM-1 and Ethernet capacity over the wireless interface. The maximum number of E1/T1 links over the wireless interface is dependent on the TDM switch capacity of the Master I/O module, the number of termination ports, as well as the link capacity of the modulation mode.

Available Ethernet payload capacity is automatically calculated following the selection of the desired TDM payload capacity. Ethernet input/termination capacity greater than 98.7 Mbps is not supported unless a GigE Master I/O module is installed. Update the TDM payload capacity as required and select Next.

The web interface displays 100 Mbps, but the maximum user data capacity for Fast Ethernet is 98.7 Mbps.

Figure 102 Payload Configuration page

Page 389: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 3: Configuring wireless interface

phn-2779_001v000 (Jul 2012) 6-29

ODU Tx Power Configuration

The ODU Tx Power Configuration page (Figure 103) is the fourth Link Configuration page (menu option Link Configuration, Radio Link, Link Configuration).

Update the ODU Tx Configuration attributes (Table 232) and select Next.

Tx Power is limited by the ODU Maximum and Minimum values. The Tx Power level can be further restricted by the selected IDU Operational Mode. If a Tx Power level is entered that is above the maximum allowed Tx value (based on the ODU value or a more restrictive IDU Operational Mode file value), there is no explicit error message generated, but the entry will be rejected.

Figure 103 ODU Tx Power Configuration page

Page 390: Cambium network ptp 810 series 01 00 user guide

Task 3: Configuring wireless interface Chapter 6: Configuration and alignment

6-30 phn-2779_001v000 (Jul 2012)

Table 232 ODU Tx Power Configuration attributes

Attribute Meaning

Type ‘HT’ means that the ODU is high transmit frequency.

‘LT’ means that the ODU is low transmit frequency.

The MMU obtains this attribute from the ODU; it cannot be updated from the web interface.

Start Tx Power The required starting Tx power of the ODU.

Tx Power The current Tx power of the ODU. This is automatically updated on completion of the Link Configuration Wizard.

Update Remote Tx Power

The starting Tx Power of the remote ODU in the link is automatically updated to match that of the local ODU.

ODU Channel Selection

The ODU Channel Selection page (Figure 104) is the fifth Link Configuration page (menu option Link Configuration, Radio Link, Link Configuration).

Select the Manual Frequency Entry radio button, then enter the ODU center Tx frequency value in units of GHz.

The MMU will read the Tx Spacing configuration parameter from the ODU and display it along with calculating the corresponding ODU center Rx frequency.

Pre-configuration of the Tx frequency without an ODU attached to the MMU modem is not supported.

The MMU will only ensure that the center Tx frequency value is within the allowed frequency range of the ODU, but it will not protect against selecting a center Tx frequency that is so close to the high or low end points in the allowed Tx frequency range that the bandwidth of the channel will exceed the max. or min. values of the allowed Tx frequency range.

Select Next.

Page 391: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 3: Configuring wireless interface

phn-2779_001v000 (Jul 2012) 6-31

Figure 104 ODU Channel Selection page

Adaptive Coding/Modulation

The Adaptive Coding/Modulation page (Figure 105) is the sixth Link Configuration page (menu option Link Configuration, Radio Link, Link Configuration).

Release 01-00 of the PTP 810 MMU does not support Adaptive Coding Modulation, but it does not block it either.

Select the Disabled radio button and press Next.

Figure 105 Adaptive Coding Modulation page

Page 392: Cambium network ptp 810 series 01 00 user guide

Task 3: Configuring wireless interface Chapter 6: Configuration and alignment

6-32 phn-2779_001v000 (Jul 2012)

Summary of Configurations (Redo or Update)

The Summary of Configurations page with Redo and Update All buttons (Figure 106) is the last Link Configuration page (menu option Link Configuration, Radio Link, Link Configuration).

Choose whether to cancel or apply the configuration changes:

• To cancel all changes and retain existing configuration, select Redo.

• To apply all changes to the link configuration, select Update All. Wait for the update process to complete; it will take up to two minutes.

Page 393: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 3: Configuring wireless interface

phn-2779_001v000 (Jul 2012) 6-33

Figure 106 Summary of Configurations page with Redo and Update All buttons

Configuring the ODU

Action to be taken on ODU communication failure

The ODU Tx Mute Configuration option is not available if the MMU is in 1+1 Hot Standby operation.

Page 394: Cambium network ptp 810 series 01 00 user guide

Task 3: Configuring wireless interface Chapter 6: Configuration and alignment

6-34 phn-2779_001v000 (Jul 2012)

To configure the action to be taken in the event of an ODU communication failure, select menu option Link Configuration, Radio Link, ODU Tx Mute Config. The ODU Tx Mute page is displayed (Figure 107). This page is not available in the case of protected (1+1) operation.

Click on the required Action on ODU Comm Failure radio button:

• ‘Mute’ means that the ODU will be muted to prevent spurious transmission.

• ‘Output Remains Same’ means that no action will be taken on failure.

Always select ‘Output Remains Same’. The ‘Mute’ option does not allow ODU-A and ODU-B to recover after a communication failure with the MMU.

Figure 107 ODU Tx Mute page

Configuring APC and coupler loss compensation

To configure adaptive power control (APC) and coupler loss compensation, select menu option Link Configuration, Radio Link, APC Configuration. The APC Configuration page is displayed (Figure 108).

APC and coupler loss compensation can be configured independently.

Page 395: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 3: Configuring wireless interface

phn-2779_001v000 (Jul 2012) 6-35

Figure 108 APC Configuration page

APC

To configure APC, click on the Adaptive Power Control ‘Enabled’ radio button and update the APC attributes (Table 233). Select Update.

Table 233 APC attributes

Attribute Meaning

APC ‘Enabled’ means that adaptive power control is enabled.

‘Disabled’ means that adaptive power control is disabled.

RSL Low Threshold The Received Signal Level Low Threshold.

RSL High Threshold The Received Signal Level High Threshold.

RSL Maximum Threshold

The Received Signal Level Maximum Threshold.

Page 396: Cambium network ptp 810 series 01 00 user guide

Task 3: Configuring wireless interface Chapter 6: Configuration and alignment

6-36 phn-2779_001v000 (Jul 2012)

Attribute Meaning

CER Threshold This represents a Channel Error Rate (CER) threshold at which the MMU will request the link partner to increase power. The SNR value on the Status Panel and Graphs is derived from the CER. As CER increases the SNR decreases. The CER Threshold is set to default at 10-5, which would be approximately a BER (Bit Error Rate) of 10-12.

Tx Power Maximum Maximum allowed transmit power.

For Tx Power Maximum, use the values for the appropriate band as given in Capacity, transmit power and sensitivity on page 4-29 or in the LINKPlanner report. The default values from the modes file are not correct for all bands.

Tx Power Minimum Minimum allowed transmit power.

For Tx Power Minimum, use the values for the appropriate band as given in Capacity, transmit power and sensitivity on page 4-29 or in the LINKPlanner report. The default values from the modes file are not correct for all bands.

Step Size The size of the step increments (dB) in which the APC algorithm will raise or lower the transmit power. Default is 1 dB.

Update Far End Threshold

‘Enabled’ means that user modifications to the local MMU thresholds will be duplicated at the far end MMU.

Coupler Loss Compensation

In a 1+1 HSB configuration, when a coupler with asymmetric attenuation is used, the MMU supports the ability to compensate for coupler loss during HSB switching (assuming that this does not exceed the maximum power for the ODU or the MMU Operational Mode).

To configure coupler loss compensation, set Coupler Nominal Power Side to ‘East’ or ‘West’ to select which modem is connected to the Primary ODU and enter the additional loss of the Secondary path into the Coupler Loss field (Table 234). Select Update.

Page 397: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 3: Configuring wireless interface

phn-2779_001v000 (Jul 2012) 6-37

Table 234 Coupler loss attributes

Attribute Meaning

Coupler Nominal Power Side

Select East / West. This setting is used for 1+1 Hot Standby operation. It defines whether the East or West modem is connected to the Primary ODU. It should be set to the same value as Preferred ODU Selection (see Table 239).

Coupler Loss This defines the additional radio loss to the Secondary ODU compared to the Primary ODU. The MMU will ensure that the Secondary ODU increases its transmit power (up to the maximum configured transmit power) to compensate for any additional loss compared to the Primary ODU.

If the Primary and Secondary ODUs are connected to a single antenna through an asymmetric coupler, set this to the difference between the Main and Standby coupler losses which are defined in Table 79.

If the Primary and Secondary ODUs are connected to a single antenna through a symmetric coupler, set this to 0.

If the Primary and Secondary ODUs are connected to separate antennas, set this to the difference between the gains of the two antennas.

Page 398: Cambium network ptp 810 series 01 00 user guide

Task 4: Configuring E1/T1 interfaces Chapter 6: Configuration and alignment

6-38 phn-2779_001v000 (Jul 2012)

Task 4: Configuring E1/T1 interfaces

If only Ethernet interfaces are required, skip this task.

Perform this task to configure the E1/T1 interfaces on the PTP 810 MMU. The MMU uses Channel Mapping to configure the TDM Switch to provide the required E1/T1 routing between the front panel ports and the RF modem links. For an overview description of E1/T1 Channel Mapping and the configuration of the TDM Switch, see E1/T1 switching on page 1-59.

This task consists of the following procedures:

• Configuring channel mapping on page 6-38

• Configuring E1/T1 ports on page 6-42

• Configuring E1/T1 protection switching on page 6-45

Configuring channel mapping

To configure E1/T1 channel mapping, select menu option Link Configuration, Data Link, E1/T1 Channel Map. The E1/T1 Channel Map page is displayed (Figure 109).

Depending on the operator’s requirements, there are two ways to configure channel mapping:

• Pre-defined: Select a pre-defined channel map from the E1/T1 Channel Map page.

• Custom mapping: Type the switch mapping into the E1/T1 Channel Map page.

Pre-defined channel maps

For pre-defined channel mapping, select an option (other than ‘Custom’) from the Channel Mapping Type drop-down list (Figure 109). Select Update.

There are fourteen pre-defined channel maps. They are all intended to be examples to help in creating custom channel maps. The first eight mappings are general use cases that provision the MMU for looping back available interfaces, mapping various front panel ports to “east” mappings, mapping various front panel ports to “west” mappings and mapping various “demuxed” STM-1 channels to various front port mappings. STM-1 channels are not supported in PTP 810 01-00.

The general purpose mappings supported in PTP 810 01-00 are listed in Table 235.

Page 399: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 4: Configuring E1/T1 interfaces

phn-2779_001v000 (Jul 2012) 6-39

Table 235 General purpose mappings

Mapping Meaning

Loopback All E1/T1 ports mapped to perform local interface loopback (LIU).

All_East All E1/T1 ports mapped to East modem.

All_West All E1/T1 ports mapped to West modem.

16_East_16_West Sixteen E1/T1 ports mapped to East modem and sixteen E1/T1 ports mapped to West modem.

8_East_8_West Eight E1/T1 ports mapped to East modem and eight E1/T1 ports mapped to West modem.

The general purpose mappings not supported in PTP 810 01-00 include STM1_East, STM1_West and STM1_FP.

The remaining six pre-defined channel maps involve multiple MMUs and are intended as examples for testing purposes. These complex mappings utilize internal cross-connections and require external cross-connections and are not within the scope of this document.

Figure 109 E1/T1 Channel Map page (pre-defined mapping)

Page 400: Cambium network ptp 810 series 01 00 user guide

Task 4: Configuring E1/T1 interfaces Chapter 6: Configuration and alignment

6-40 phn-2779_001v000 (Jul 2012)

The contents of the selected Channel Mapping Type are displayed in the Channel Map field. The naming convention is described in Table 236.

Table 236 Naming convention used in channel maps

Designation Example Meaning

En E2 East modem timeslot number.

Wn W3 West modem timeslot number.

MAn MA4 Master IO card front panel port number.

EXn EX2 Expansion IO card front panel port number.

In the example shown in Figure 109, the MMU was configured in a 4-E1, 1+0 mode such that only the first four timeslots on the East modem are available (E1-E4). This is reflected in the four mappings containing E1-E4 listed under ‘Valid Mappings’. The additional mappings, pointing to unavailable modem timeslots, are grouped under the ‘Unused Mappings’.

Instead of creating a dedicated mapping for each mode, simply create a set of generic mappings. The software automatically ignores any mappings that do not apply to the current mode.

Custom channel maps

For custom channel mapping, select ‘Custom’ from the Channel Mapping Type drop-down list (Figure 110). Type the channel mapping into the Channel Map field. Use the naming convention described in Table 236.

Before selecting Update, ensure that:

• All available front panel ports are mapped.

• A modem timeslot is not mapped more than once.

• For pass-throughs, an East modem timeslot is mapped to a corresponding West modem timeslot.

Select Update.

In the example shown in Figure 110, a switch mapping has been typed into the Channel Map display. This mapping configures the TDM Switch to connect the first four East timeslots to the first four Master IO front panel ports, and the first four West timeslots to Master IO ports 5-8. After selecting Update, the TDM Switch is reconfigured. The resulting screen is shown in Figure 111.

Page 401: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 4: Configuring E1/T1 interfaces

phn-2779_001v000 (Jul 2012) 6-41

Figure 110 E1/T1 Channel Map page (custom mapping)

Figure 111 E1/T1 Channel Map page (custom mapping updated)

Page 402: Cambium network ptp 810 series 01 00 user guide

Task 4: Configuring E1/T1 interfaces Chapter 6: Configuration and alignment

6-42 phn-2779_001v000 (Jul 2012)

The resulting mapping in this example is grouped in the same way as in the pre-defined mapping example. Because the MMU is configured in a 4-E1, 1+0 mode, the West modem mappings are all set as unused. If the system is reconfigured to 2+0 operation, the west mappings are automatically connected and moved to the “Valid Mappings” list. The custom channel maps can continue to be edited.

A pre-defined channel map can also be copied and pasted into the Channel Map field. The map can then be edited and updated: only the changed E1/T1 links will be affected. All other E1/T1 links will continue to pass data error free.

Channel map errors

The E1/T1 Channel Map page attempts to catch any errors. This is especially useful when editing custom channel maps. The system groups mappings into four basic categories:

• ‘Valid Mappings’: These are syntactically correct mappings which are valid with the current hardware and mode.

• ‘Unused Mappings’: These are syntactically correct mappings, but either the mode or the installed hardware makes them impossible to connect. If the mode is changed, or other hardware is installed (for example, a different Master IO card or an Expansion IO card is added), these mappings will be automatically moved to the valid list.

• ‘Invalid Mappings’: These mappings have a syntax error. They might refer to an invalid port number, or have a spelling mistake.

• ‘Incomplete Mappings’: This is a summary of all of the modem timeslots that are available in the current mode, but either do not have a mapping defined, or have an invalid mapping defined.

Configuring E1/T1 ports

Before configuring E1/T1 related parameters, ensure that the Master IO card is configured and present. Otherwise an error message will be displayed.

To configure E1/T1 channel related parameters, select menu option Link Configuration, Data Link, E1/T1 Ports. The E1/T1 Configurations page is displayed (Figure 112).

To configure a channel: tick the Apply Settings box, update the required parameters under New Settings (Table 237), then select Update.

To revert to the previous values, select Reset.

Page 403: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 4: Configuring E1/T1 interfaces

phn-2779_001v000 (Jul 2012) 6-43

Figure 112 E1/T1 Configurations page

Page 404: Cambium network ptp 810 series 01 00 user guide

Task 4: Configuring E1/T1 interfaces Chapter 6: Configuration and alignment

6-44 phn-2779_001v000 (Jul 2012)

Table 237 E1/T1 Configurations attributes

Attribute Meaning

Physical Channel All configured channels are displayed with their current configurations. Inactive channels appear in grey. The number of available channels is dependent on the MMU configuration.

‘MA’ means that the channel is a Master IO card front panel port.

‘EX’ means that the channel is an Expansion IO card front panel port.

Apply Settings When ticked, the parameters of this Physical Channel are displayed under New Settings.

Encoding The encoding method used for this channel.

‘B8ZS’ means Bipolar with Eight Zero Substitution.

‘AMI’ means Alternate Mark Inversion.

TX Data The type of TX data stream sent over this channel.

‘Normal’ means that the channel transmits what is received on the front-panel port onto the RF link.

‘All Ones’ means that the channel replaces the transmit data with a stream of all ones (1111111…), effectively generating an alarm condition. This is useful in some debug contexts.

Loopback The type of loopback employed over this channel.

‘Normal’ means no loopback operation.

‘Far’ means loopback E1/T1 signal received from RF Link back to RF Link.

‘Near ‘ means loopback E1/T1 signal received on front-panel port back out the front-panel port.

LOS Action The action to be taken when an LOS is detected at the input to the front-panel E1/T1 port.

‘AIS’ means generate an AIS signal to be transmitted on the RF link for the E1/T1 channel.

‘Nothing’ means transmit what is received on the front-panel port on the RF link.

LOS/AIS Detection LOS and AIS detection criteria based upon the specified standards (G.775, I.431/ETSI, T1.231 or I.431/T1.231). Depending on the channel type (E1/T1) configuration, the choices displayed will differ.

Page 405: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 4: Configuring E1/T1 interfaces

phn-2779_001v000 (Jul 2012) 6-45

Attribute Meaning

Build Out Build out criteria. Depending on the channel type (E1/T1) configuration, the choices displayed will differ.

Configuring E1/T1 protection switching

E1/T1 Protection Switching or SNCP-Like switching is a feature to provide the redundant path on failure.

PTP 810 only supports SNCP-like protection switching. Set the ‘SNCP upon BER’ attribute to ON.

To configure E1/T1 protection switching, select menu option Link Configuration, Data Link, E1/T1 Protection Switching. The E1/T1 Protection Switching page is displayed (Figure 113).

Update the attributes (Table 238), then select Update. To revert to the previous values, select Reset.

Figure 113 E1/T1 Protection Switching page

Page 406: Cambium network ptp 810 series 01 00 user guide

Task 4: Configuring E1/T1 interfaces Chapter 6: Configuration and alignment

6-46 phn-2779_001v000 (Jul 2012)

Table 238 E1/T1 Protection Switching attributes

Attribute Meaning

SNCP upon BER ‘ON’ means that sub-network connection protection (SNCP) is enabled in E1/T1 path.

Trigger Threshold Only available when SNCP upon BER is ‘ON’.

Threshold parameter for BER, above which it triggers the protection switching by inserting AIS on the working path.

Clear Threshold Only available when SNCP upon BER is ‘ON’.

Threshold parameter for BER, below which it removes the AIS from the working path.

Hold off Timer Only available when SNCP upon BER is ‘ON’.

Wait duration by system to insert the AIS upon BER reached above the trigger threshold.

Enable Protection ‘Enable’ means that E1/T1 protection switching is enabled.

Select All Apply this configuration to all channels rather than one selected channel.

Hold off Only available when Enable Protection is ‘Enable’.

Wait time to switch between the working to protection and vice versa after system finds fault with the current E1/T1 data path.

Lockout of Protection Only available when Enable Protection is ‘Enable’.

The system will never switch to protection path for the particular couplet.

Forced Switch to Protection

Only available when Enable Protection is ‘Enable’.

The system will switch the data to protection path irrespective of protection path status.

Forced Switch to Working

Only available when Enable Protection is ‘Enable’.

The system will switch the data to working path irrespective of working path status.

Manual Switch to Protection

Only available when Enable Protection is ‘Enable’.

The system will switch the data to protection path, only if the protection path works fine.

Page 407: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 4: Configuring E1/T1 interfaces

phn-2779_001v000 (Jul 2012) 6-47

Attribute Meaning

Manual Switch to Working

Only available when Enable Protection is ‘Enable’.

The system will switch the data to working path, only if the working path works fine.

Clear Clears any local user command.

Page 408: Cambium network ptp 810 series 01 00 user guide

Task 5: Configuring data orderwire Chapter 6: Configuration and alignment

6-48 phn-2779_001v000 (Jul 2012)

Task 5: Configuring data orderwire

Perform this task to configure a serial data orderwire channel over the wireless link.

The MMU enables an auxiliary serial data orderwire (DOW) channel for control of external equipment. The channel will support operation at a rate of 64 kbps using the RS-422 protocol or 19.2 kbps using the RS-232 protocol.

Configuring orderwire

To configure data orderwire, select menu option Link Configuration, Data Link, Orderwire. The Voice Orderwire Configuration page is displayed (Figure 114). Select the value for the DOW Mode (RS-232 / RS-422). Select Update.

The Voice Orderwire Configuration page allows the configuration of both voice orderwire (VOW) and data orderwire (DOW), but VOW is not supported in PTP 810.

Page 409: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 5: Configuring data orderwire

phn-2779_001v000 (Jul 2012) 6-49

Figure 114 Voice Orderwire Configuration

Page 410: Cambium network ptp 810 series 01 00 user guide

Task 6: Configuring protection Chapter 6: Configuration and alignment

6-50 phn-2779_001v000 (Jul 2012)

Task 6: Configuring protection

Perform this task if the PTP 810 link is to be protected. This task is the same for both 1+1 HSB and 1+1 HSB SD. This task consists of the following procedure:

• Configuring protection on page 6-50

Configuring protection

The Protection Configuration page is available only if the MMU is configured for 1+1 operation (that is, two Modem/IF Modules and two Power Supply Modules are installed in the MMU).

To configure link protection, select menu option Link Configuration, Radio Link, Protection Configuration. The Protection Configuration page is displayed (Figure 115). Update the attributes (Table 239) and select Update.

Figure 115 Protection Configuration page

Page 411: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 6: Configuring protection

phn-2779_001v000 (Jul 2012) 6-51

Table 239 Protection Configuration attributes

Attribute Meaning

Power down ODU after switch

‘Enabled’ means that the ODU is powered down after a protection switch. Use this option to ensure that the ODU that had a fault does not transmit outside of a licensed band. If 'Enabled' is selected and a protection switch occurs, the MMU will attempt to power up the ODU that had a fault automatically after 3 minutes (as stand-by ODU). It will automatically power down the ODU that had a fault if an alarm condition still exists.

Preferred ODU Select East or West. This defines whether the East or West modem is connected to the Primary ODU. This is the preferred ODU for transmitting and must be connected to the antenna or coupler with the lowest path loss. For 1+1 Hot Standby deployments where the ODUs are coupled to a common antenna, the Primary ODU must connect to the side of the coupler labeled MAIN. For 1+1 deployments where the ODUs are connected to separate antennas, the Primary ODU connects to the antenna with the highest gain. If the gains are equal, either ODU can be the Primary ODU.

If the East modem is connected to the Primary ODU, set this to East. If the West modem is connected to the Primary ODU, set this to West.

APS Switch (Automatic Protection Switch)

‘Enabled’ means that 1+1 Hot Standby Tx switching is enabled. This would normally be set to enabled, but could be disabled to allow for system maintenance on a live link. Disabling this feature turns off the ODU Alarm, ODU Hot-Swap and Remote Switching. Remote Switching has a separate user configurable option for enabling and disabling.

Remote Transmitter Switching

Remote Transmitter Switching is a method by which a 1+1 Hot Standby protected link can try to recover from a one way lock condition. For more information, refer to Remote transmitter switching algorithm on page 6-52.

Update Remote APS Switch

An update to enable or disable APS on the local MMU will likewise enable or disable APS on the remote MMU.

Switch Transmitting ODU

User initiated transmit protection switch.

Page 412: Cambium network ptp 810 series 01 00 user guide

Task 6: Configuring protection Chapter 6: Configuration and alignment

6-52 phn-2779_001v000 (Jul 2012)

Remote transmitter switching algorithm

The algorithm is visually explained in Figure 116. By enabling the feature, it allows a near end MMU to monitor the Lock Status of the remote MMU. If a one way link occurs due to, for example, a transmitter failure on the near side ODU that does not trigger an ODU alarm, the far end Lock Status will become ’Unlocked’. The near end MMU will perform a protection switch to try to recover by switching to the stand-by ODU.

In other words, the near end ODU may have a transmitter failure, but no issue with its receiver. In this case, it can still receive Lock Status information from the far side. The far side can, in effect, tell the near side that it is no longer locked (not receiving a signal). The near side will perform a protection switch based on this data if Remote Switching is enabled.

The switching takes place at the system software application level. This feature is not designed as a fast protection switch but rather further redundancy to recover a link in a situation in which the ODU cannot self detect a transmit alarm condition.

Page 413: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 6: Configuring protection

phn-2779_001v000 (Jul 2012) 6-53

Figure 116 Remote transmit switch algorithm

Page 414: Cambium network ptp 810 series 01 00 user guide

Task 7: Setting up SNMP agent Chapter 6: Configuration and alignment

6-54 phn-2779_001v000 (Jul 2012)

Task 7: Setting up SNMP agent

Perform this task to configure SNMP, if required.

Configuring SNMP agent

Perform this procedure to configure the system to generate Simple Network Management Protocol (SNMP) traps.

To configure the SNMP agent, select menu option Administration, Network Configuration, SNMP. The SNMP Configuration page is displayed (Figure 117). Update the attributes (Table 226) and select Update.

Figure 117 SNMP Configuration page

Page 415: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 7: Setting up SNMP agent

phn-2779_001v000 (Jul 2012) 6-55

Table 240 SNMP Configuration attributes

Attribute Meaning

SNMP Mode Mode in which SNMP Agent is currently configured (v1-v2-v3 / v1 only / v2 only / v3 only / Disabled)

Trap Version Trap Version in which SNMP Agent is currently configured (v1 / v2).

A trap is an SNMP message issued by an SNMP agent that reports an event.

The Trap Version parameter configures the SNMP trap version. The SNMP agent uses the specified version to send the traps to configured trap managers.

Auth Trap Enable Enable/Disable sending of authorization traps to SNMP manager.

When enabled, SNMP agent generates Authentication failure trap on authentication failure in any request.

Read Community Community String used while reading data from the SNMP Agent in SNMP V1/V2 mode.

A community string is an SNMP security password. The Read Community string is used in read operation of SNMP v1 or v2, and allows the SNMP manager to issue Get and GetNext messages.

Write Community Community String used while writing data to the SNMP Agent in SNMP V1/V2 mode.

The Write Community string is used in write operation of SNMP v1 or v2, and allows the SNMP Manager to issue Set messages.

Trap Community Community String used while sending traps from the SNMP Agent.

The Trap Community string allows the SNMP agent to issue Trap messages.

SNMP Auth Password Password required for authorization while reading or writing data in SNMP V3 Mode.

The SNMP Auth Password is used in only SNMP v3 mode of operation and is the authorization password for the ‘admin’ user.

Page 416: Cambium network ptp 810 series 01 00 user guide

Task 7: Setting up SNMP agent Chapter 6: Configuration and alignment

6-56 phn-2779_001v000 (Jul 2012)

Attribute Meaning

SNMP Priv Password Privacy password required while reading or writing data in SNMP V3 Mode.

The SNMP Priv Password is used in only SNMP v3 mode of operation and is the privacy password for the ‘admin’ user.

Trap Manager #1 - #4 IP Addresses of the Trap Managers to which Traps are to be sent.

Trap Manager configures the trap manager’s IP addresses. A maximum of four Trap managers can be configured. The SNMP agent sends the traps to all the configured trap managers.

The MMU implements SNMPv3 as follows:

• Auth Protocol: MD5

• Priv Protocol: DES

• Security model: ‘authPriv’ with authentication and with privacy

To access the MMU via SNMPv3 both Auth password and Priv password (passwords length >= 8 characters) are required. For the default security name ’admin’, Auth and Priv passwords can be configured from Web GUI and SNMP Configuration.

Page 417: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 8: Configuring alarms and messages

phn-2779_001v000 (Jul 2012) 6-57

Task 8: Configuring alarms and messages

This task consists of the following procedures:

• Configuring generation of diagnostics alarms on page 6-57

• Configuring alarm thresholds on page 6-59

Configuring generation of diagnostics alarms

To select which diagnostic alarms will be notified to the system administrator, select menu option Analysis, Alarms, Alarm Configuration. The Alarm Configuration page is displayed (Figure 118). The full list of alarms is described in Alarms on page V. Update attributes as required (Table 241) and select Update.

To mask all alarms, select Check All Mask.

To unmask all alarms, select Uncheck All Mask.

To activate E-mail notification for all alarms, select Check All Mail.

To deactivate E-mail notification for all alarms, select Uncheck All Mail.

PTP 810 does not support E-mail notification for alarms. Select Uncheck All Mail to deactivate this feature.

Page 418: Cambium network ptp 810 series 01 00 user guide

Task 8: Configuring alarms and messages Chapter 6: Configuration and alignment

6-58 phn-2779_001v000 (Jul 2012)

Figure 118 Alarm Configuration page

Page 419: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 8: Configuring alarms and messages

phn-2779_001v000 (Jul 2012) 6-59

Table 241 Alarm Configuration attributes

Attribute Meaning

Description Displays the description of the alarm. If an alarm is active (set), the description of that alarm is red in color.

Mask Masking of a particular alarm. If checked , that particular alarm will be ignored. A masked alarm being “ignored” means the alarm will not appear in the Analysis, Alarms, Active page or in the Analysis, Alarms, History page from the time that the alarm was masked. The alarms will also not appear in the Alarm screens of the CLI.

E-mail If checked, upon occurrence of this alarm the configured users are notified by E-mail.

Severity Displays the type of the alarm (Critical / Major / Info).

AL1 – AL4 Maps alarm output to one of the four external alarm outputs.

Configuring alarm thresholds

To configure alarm threshold parameters, select menu option Analysis, Alarms, Threshold. The Alarm Threshold page is displayed (Figure 119). Update attributes as required (Table 242) and select Update.

Page 420: Cambium network ptp 810 series 01 00 user guide

Task 8: Configuring alarms and messages Chapter 6: Configuration and alignment

6-60 phn-2779_001v000 (Jul 2012)

Figure 119 Alarm Threshold page

Page 421: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 8: Configuring alarms and messages

phn-2779_001v000 (Jul 2012) 6-61

Table 242 Alarm Threshold attributes

Attribute Meaning

RSL Alarm Threshold Threshold value for RSL alarm (in ‘dBm’ units).

SNR Threshold Threshold value for Signal/Noise alarm (in ‘dB’ units).

Max/Min MMU Temperature

Threshold values for temperature alarm (in ‘Celsius’ units).

Max/Min ODU Temperature (East and West)

Threshold values for temperature alarm (in ‘Celsius’ units).

External Alarm Signal Level

Select Active Low or Active High. These correspond to the four external alarm inputs available on the Control Module DB15 connector: pins 9, 14, 10 and 15 and they default to ‘active low’. Each alarm input can be configured to be ’active high’ (pulled down to GND with a 10K Ω resistor) or ’active low’ (pulled up to +5 VDC with a 10K Ω resistor). Voltage swings on these alarm inputs should not exceed 0 to 5 VDC.

Jumper positions

Based on the ‘External Alarm Signal Level’ radio button selection, the external alarm input jumper positions are displayed on the Alarm Threshold page (Figure 119).

The Control Module has configurable shunt jumpers to control the active polarity of these signals. The diagram above identifies which jumpers to manipulate as required when the ‘Active Low’ or ‘Active High’ state is selected.

The jumpers shown on the Alarm Threshold page represent the jumpers located on the left side, top of the controller card. These jumpers have to be physically placed to match the picture shown on this page. Operators can change these jumper settings at their discretion to be driven by the specific external devices at a particular operator site (such as a sensor indicating a door open to the building where the MMU is located).

Page 422: Cambium network ptp 810 series 01 00 user guide

Task 9: Configuring syslog Chapter 6: Configuration and alignment

6-62 phn-2779_001v000 (Jul 2012)

Task 9: Configuring syslog

Perform this task when system logging is required.

For more information on syslog, refer to Managing event notification messages on page 7-20.

Configuring system logging (syslog)

Only users with ‘Administrator’ access rights are permitted to configure the syslog client.

To configure system logging, select menu option Administration, Network Configuration, Syslog Server Configuration. The Syslog Configuration page is displayed (Figure 120). Update the attributes as required (Table 243), then select Update.

Figure 120 Syslog Configuration page

Table 243 Syslog Configuration attributes

Attribute Meaning

Syslog Server The IP Address of the Syslog server. If unsure contact your network administrator.

Syslog Facility Syslog facilities in accordance with the standard UNIX Syslog facilities Local0 – Local7, which are eight facilities identified for customized auditing.

Page 423: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 10: Configuring quality of service

phn-2779_001v000 (Jul 2012) 6-63

Task 10: Configuring quality of service

Perform this task when configuration of Ethernet Quality of Service is required.

This task consists of the following procedures:

• Setting QoS priority method on page 6-63

• Setting QoS port priorities on page 6-66

• Setting QoS VLAN p-bit tag priorities on page 6-68

• Setting QoS DiffServ DSCP priorities on page 6-69

• Setting QoS switch priorities on page 6-71

Setting QoS priority method

To choose which QoS priority method is to be enabled, select menu option Administration, QoS Configuration, Global Settings. The installed Master I/O module determines which QoS Global Configuration page is displayed.

Standard Master I/O module

For an MMU with the Standard Master I/O module installed, the QoS Global Configuration page is displayed as shown in Figure 121. Update the attributes as required (Table 244), then select Update.

Figure 121 QoS Global Configuration page (Standard Master I/O module)

Page 424: Cambium network ptp 810 series 01 00 user guide

Task 10: Configuring quality of service Chapter 6: Configuration and alignment

6-64 phn-2779_001v000 (Jul 2012)

Table 244 QoS Global Configuration attributes (Standard Master I/O module)

Attribute Meaning

Port Priority Enabled or Disabled.

VLAN p-bit Tag Priority

Enabled or Disabled.

DiffServ Priority Enabled or Disabled.

Priority Resolution Only available when both VLAN p-bit TAG Priority and DiffServ Priority are ‘Enabled’. Resolves which QoS protocol (VLAN p-bit TAG or Diffserv) will be used to determine the priority queue.

If VLAN p-bit TAG is selected as the Priority Resolution, the p-bit will be used to determine the priority queue on a packet that has both p-bit and DSCP field. On a packet that has no p-bit (because it is not VLAN tagged), the DSCP field will be used to determine the priority queue.

If Diffserv is selected as the Priority Resolution, only the DSCP field will be used to determine the priority queue on a packet, while p-bit will be ignored.

Queue Scheduling Policy

The queue scheduling policy: ‘Strict Priority Scheme’ or ‘Weighted Fair Queuing Scheme’.

GigE Master I/O module

For an MMU with the GigE Master I/O module installed, the QoS Global Configuration page is displayed as shown in Figure 122. Update the attributes as required (Table 245), then select Update.

Page 425: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 10: Configuring quality of service

phn-2779_001v000 (Jul 2012) 6-65

Figure 122 QoS Global Configuration page (GigE Master I/O module)

Page 426: Cambium network ptp 810 series 01 00 user guide

Task 10: Configuring quality of service Chapter 6: Configuration and alignment

6-66 phn-2779_001v000 (Jul 2012)

Table 245 QoS Global Configuration attributes (GigE Master I/O module)

Attribute Meaning

Port Priority Select Enabled / Disabled.

VLAN p-bit Tag Priority

Select Enabled / Disabled.

DiffServ Priority Select Enabled / Disabled.

High Queue Preempt

Select Enabled / Disabled. High Queue Preempt services the highest priority queue, interrupting the weighted fair queuing, as needed. When the highest priority queue is empty, the remaining queues are serviced per the weighted fair queuing algorithm and configured weights.

Priority Queue Weight 0 - 3

Set the number of Tx packets per round (1-49) for each priority queue weight.

Setting QoS port priorities

Use the QoS Port Priority Map page to map traffic from Ethernet (FE or GE) ports to specific priority queues. To set the QoS port priority mappings, select menu option Administration, QoS Configuration, Port Priority. The installed Master I/O module determines which QoS Port Priority Map page is displayed.

Standard Master I/O module

For an MMU with the Standard Master I/O module installed, the QoS Port Priority Map page is displayed as shown in Figure 123.

Use this page to configure the QoS priority for front panel Ports 1 and 2 and the East and West radio ports. Enter the frame priority for each port (0 Low - 3 High). Select Update.

Page 427: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 10: Configuring quality of service

phn-2779_001v000 (Jul 2012) 6-67

Figure 123 QoS Port Priority Map page (Standard Master I/O module)

GigE Master I/O module

For an MMU with the GigE Master I/O module installed, the QoS Port Priority Map page is displayed as shown in Figure 124.

Use this page to configure the QoS priority for front panel Ports 1 – 4, the SFP port priority (available only if the SFP module is installed) and the East and West radio ports. Enter the frame priority for each port (0 Low – 7 High). Select Update.

Page 428: Cambium network ptp 810 series 01 00 user guide

Task 10: Configuring quality of service Chapter 6: Configuration and alignment

6-68 phn-2779_001v000 (Jul 2012)

Figure 124 QoS Port Priority Map for GigE Master I/O module

Setting QoS VLAN p-bit tag priorities

Use the QoS VLAN p-bit Tag Priority Map page to map VLAN tagged packets to specific priority queues based upon the priority field in the VLAN tag (IEEE 802.1Q).

To set the QoS VLAN p-bit tag priority mappings, select menu option Administration, QoS Configuration, VLAN p-bit Tag Priority. The QoS VLAN p-bit Tag Priority Map page is displayed (Figure 125). Both the Standard Master I/O module and the GigE Master I/O module display the same version of this page.

Enter the frame priority for each tag. The GigE Master I/O module supports prioritization values of 0-7. The Standard Master I/O module supports prioritization values of 0-3. The default frame priority values for tag priorities will differ with the installed Master I/O module. Select Update.

Page 429: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 10: Configuring quality of service

phn-2779_001v000 (Jul 2012) 6-69

Figure 125 QoS VLAN p-bit Tag Priority Map page

Setting QoS DiffServ DSCP priorities

Use the QoS DiffServ DSCP Map page to map IPv4 packets to specific priority queues based upon the DS field in the IPv4 header (see RFC 2474). To set the QoS DiffServ DSCP mappings, select menu option Administration, QoS Configuration, DiffServ Priority. The installed Master I/O module determines which QoS DiffServ DSCP Map page is displayed.

Standard Master I/O module

For an MMU with the Standard Master I/O module installed, the QoS DiffServ DSCP Map page is displayed as shown in Figure 126. Use this page to configure the QoS DiffServ DSCP Priority Map for DSCP Priority 0 – DSCP Priority 63. Enter the Tx queue for each DSCP priority (0 Low – 3 High). Select Update.

Page 430: Cambium network ptp 810 series 01 00 user guide

Task 10: Configuring quality of service Chapter 6: Configuration and alignment

6-70 phn-2779_001v000 (Jul 2012)

Figure 126 QoS DiffServ DSCP Map page (Standard Master I/O module)

GigE Master I/O module

For an MMU with the GigE Master I/O module installed, the QoS DiffServ DSCP Map page is displayed as shown in Figure 127. Use this page to configure the QoS DiffServ DSCP Priority Map for DSCP Priority 0 – DSCP Priority 63. Enter the switch priority for each DSCP (switch priority: 0 Low – 7 High). The Switch Priority is an intermediate internal eight-level priority value which is assigned to the packets as they ingress the switch. Select Update.

Page 431: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 10: Configuring quality of service

phn-2779_001v000 (Jul 2012) 6-71

Figure 127 QoS DiffServ DSCP Priority Map for GigE Master I/O module

Setting QoS switch priorities

Use the QoS Switch Priority Map page used to configure an MMU with the GigE Master I/O module installed.

To set the QoS switch priority mappings, select menu option Administration, QoS Configuration, Switch Priority. The Switch Priority to Tx Priority Queue Map page is displayed (Figure 128).

Page 432: Cambium network ptp 810 series 01 00 user guide

Task 10: Configuring quality of service Chapter 6: Configuration and alignment

6-72 phn-2779_001v000 (Jul 2012)

Use this page to configure the QoS Switch Priority to Tx Priority Queue Map for Switch Priority 0 – Switch Priority 7. Enter the Tx queue for each switch priority (0 Low – 3 High). Select Update.

Figure 128 Switch Priority to Tx Priority Queue Map (GigE Master I/O module)

Page 433: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 11: Configuring VLAN

phn-2779_001v000 (Jul 2012) 6-73

Task 11: Configuring VLAN

Perform this task when configuration of Ethernet Virtual Local Area Networks (VLANs) is required. For an overview of VLAN operation, see Ethernet bridging in the customer network on page 1-38.

This task consist of the following procedures:

• Configuring global VLAN options on page 6-73

• Configuring static VLANs on page 6-75

• Configuring port based VLANs on page 6-77

• Configuring MSTPs on page 6-88

• Mapping VLANs to MSTP instances on page 6-91

To assist with VLAN configuration, two example VLAN configurations are provided in Example VLAN configurations on page 6-78.

Configuring global VLAN options

To configure global VLAN options, select menu option Administration, VLAN Configuration, Global VLAN Configuration. The Global VLAN Configuration page is displayed (Figure 129). Update the attributes (Table 246) and select Update.

Page 434: Cambium network ptp 810 series 01 00 user guide

Task 11: Configuring VLAN Chapter 6: Configuration and alignment

6-74 phn-2779_001v000 (Jul 2012)

Figure 129 Global VLAN Configuration page

Table 246 Global VLAN Configuration attributes

Attribute Meaning

VLAN Management Select VLAN operation (Disable, Single Tag, Double Tag (Stag+Ctag), Double Tag (Ctag+Ctag).

Default VLAN ID For each port select the default VLAN ID for packets that are untagged on ingress.

Default Priority For each port select the default VLAN Priority for packets that are untagged on ingress.

Page 435: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 11: Configuring VLAN

phn-2779_001v000 (Jul 2012) 6-75

Attribute Meaning

Ingress Policy For each port select the Ingress Policy (Admit All, Admit Tag Only) to be used for each port. Either all frames will be admitted or only 802.1Q frames will be admitted for ingress on the specified port. This configuration is only available when configured for Single Tag operation.

Egress Policy For each port select the Egress Policy (Remove, Don’t Remove) to be used for each port. Either the 802.1Q tag will be removed or it won’t be removed when the frame egresses on the specified port. This configuration is only available when configured for Single Tag operation.

Port Double Tag For each port select the Port Double Tag Mode (Network, User) to be used for each port. This selection is only available when configured for Double Tag operation.

Configuring static VLANs

To configure static VLANs, select menu option Administration, VLAN Configuratio, Static VLAN Configuration. The Static VLAN Configuration page is displayed with the currently configured VLANs in the Current Static VLAN Entries table (Figure 130). By default, all the ports are included in a “Default” VLAN with VLAN ID 1.

To add a new static VLAN entry, select Add New VLAN.

To edit a static VLAN entry, click on the pencil icon in the Edit column on the appropriate static VLAN entry row.

To remove a static VLAN entry, click on the red X in the Delete column on the appropriate static VLAN entry row.

Page 436: Cambium network ptp 810 series 01 00 user guide

Task 11: Configuring VLAN Chapter 6: Configuration and alignment

6-76 phn-2779_001v000 (Jul 2012)

Figure 130 Static VLAN Configuration

For new or edited static VLANs, the Add/Edit VLAN Configuration page is displayed (Figure 131). Update the attributes (Table 247) and select Update.

Figure 131 Add/Edit VLAN Configuration

Page 437: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 11: Configuring VLAN

phn-2779_001v000 (Jul 2012) 6-77

Table 247 Add/Edit VLAN Configuration attributes

Attribute Meaning

VLAN ID The VLAN ID of the static VLAN entry.

VLAN Name A descriptive name for the static VLAN entry.

Port ‘Include’ means the port is included in the static VLAN entry.

‘Exclude’ means the port is excluded from the static VLAN entry.

East/West For the VLAN ID, select whether to include or exclude the East modem port and the West modem port as part of the VLAN.

Configuring port based VLANs

To configure port based VLANs, select menu option Administration, VLAN Configuration, Port Based Forwarding. The Port Based Forwarding Mode page is displayed (Figure 132). Select the appropriate checkboxes to enable forwarding between ports. Select Update.

Figure 132 Port Based Forwarding Mode page

Page 438: Cambium network ptp 810 series 01 00 user guide

Task 11: Configuring VLAN Chapter 6: Configuration and alignment

6-78 phn-2779_001v000 (Jul 2012)

Example VLAN configurations

To assist with VLAN configuration, two example VLAN configurations are provided here. The first example gives the procedures for a Static Tag Based VLAN configuration. The second example gives the procedures for a Port Based VLAN configuration.

Static tag based VLAN configuration

When configuring the 2+0 with trunk mode, do not perform this procedure. See Link Aggregation on page 7-25.

This example shows the procedure to configure a Static Tag Based VLAN using the Single Tag VLAN Mode with the following configuration requirements:

• LAN Port 1 and East Port in one VLAN with VLAN ID 2.

• LAN Port 2 and West Port in another VLAN with VLAN ID 3.

• Untagged packets that ingress on LAN port 1 is added a tag with VLAN ID 2.

• Untagged packets that ingress on LAN port 2 is added a tag with VLAN ID 3.

To configure these requirements, proceed as follows:

1 Select menu option Administration, VLAN Configuration, Global VLAN Configuration. Set VLAN management to ‘Single Tag’ and select Update.

Page 439: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 11: Configuring VLAN

phn-2779_001v000 (Jul 2012) 6-79

2 Configure the Default VLAN ID and Default Priority of the LAN Ports. The MMU used Default VLAN ID and Default Priority to tag the untagged frames that ingress the port.

Page 440: Cambium network ptp 810 series 01 00 user guide

Task 11: Configuring VLAN Chapter 6: Configuration and alignment

6-80 phn-2779_001v000 (Jul 2012)

3 Configure the Ingress Policy: either to admit 802.1Q frames only, or to admit all frames for ingress on each port.

Page 441: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 11: Configuring VLAN

phn-2779_001v000 (Jul 2012) 6-81

4 Configure the Egress Policy, that is, whether or not to remove the 802.1Q tag when frames egress on the LAN Port.

Select Update.

Page 442: Cambium network ptp 810 series 01 00 user guide

Task 11: Configuring VLAN Chapter 6: Configuration and alignment

6-82 phn-2779_001v000 (Jul 2012)

5 To define ports to be included in the VLAN, select menu option Administration, VLAN Configuration, Static VLAN Configuration in the left panel. By default, all the ports are included in a “Default” VLAN with VLAN ID 1.

6 ‘Default VLAN’ is not required, so exclude it from the network. Click on the Edit icon to bring up the Add/Edit VLAN Configuration page. Exclude the ports from the Default VLAN before including them in another VLAN. When finished, select Update.

Page 443: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 11: Configuring VLAN

phn-2779_001v000 (Jul 2012) 6-83

7 Select Add New VLAN. Create a new VLAN with VLAN ID 2. Include LAN Port 1 and East Port in this VLAN. When finished, select Update.

8 Select Add New VLAN. Create a new VLAN with VLAN ID 3. Include LAN Port 2 and West Port in this VLAN. When finished, select Update.

Page 444: Cambium network ptp 810 series 01 00 user guide

Task 11: Configuring VLAN Chapter 6: Configuration and alignment

6-84 phn-2779_001v000 (Jul 2012)

9 This is the final state of the Static VLAN Configuration page with the new VLANs defined for the Single Tag VLAN.

Port Based VLAN Configuration

This example shows the procedure to configure a Port Based VLAN using the Port Based Forwarding Mode with the following configuration requirements:

• LAN Port 1 is grouped with LAN Port 4 & East Port.

• LAN Port 2 is grouped with LAN Port 3 & West Port.

• LAN Port 3 is grouped with West Port.

• LAN Port 4 is grouped with East Port.

• Any Packet (Untagged, Single or Double Tagged) ingressing at LAN Port 1 can only be forwarded out of LAN Port 4 & East Port’s respectively.

• Any Packet (Untagged, Single or Double Tagged) ingressing at LAN Port 2 can only be forwarded out of LAN Port 3 & West Port’s respectively.

• Any Packet (Untagged, Single or Double Tagged) ingressing at LAN Port 3 can only be forwarded out of West Port.

• Any Packet (Untagged, Single or Double Tagged) ingressing at LAN Port 4 can only be forwarded out of East Port.

To configure these requirements, proceed as follows:

Page 445: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 11: Configuring VLAN

phn-2779_001v000 (Jul 2012) 6-85

1 Navigate to Administration, VLAN Configuration, Port Based Forwarding Mode in the left panel. When Port Based Forwarding Mode is configured for the first time then the default configuration will be displayed.

2 Include the East port in the forwarding group of LAN Port 1. The bidirectional mapping marked in Port 1 row of Port Connection Table shown below indicates that packets ingressing at LAN Port 1 can only be forwarded to East Port & those ingressing at East Port can only be forwarded to LAN Port 1.

Page 446: Cambium network ptp 810 series 01 00 user guide

Task 11: Configuring VLAN Chapter 6: Configuration and alignment

6-86 phn-2779_001v000 (Jul 2012)

3 Include the West port in the forwarding group of LAN Port 2. The bidirectional mapping marked in Port 2 row of Port Connection Table shown below indicates that packets ingressing at LAN Port 2 can only be forwarded to West Port & those ingressing at West Port can only be forwarded to LAN Port 2.

4 Include the West port in the forwarding group of LAN Port 3. The bidirectional mapping marked in Port 3 row of Port Connection Table shown below indicates that packets ingressing at LAN Port 3 can only be forwarded to West Port & those ingressing at West Port can also be forwarded to LAN Port 3 in addition to LAN Port 2.

Page 447: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 11: Configuring VLAN

phn-2779_001v000 (Jul 2012) 6-87

5 Include the East port in the forwarding group of LAN Port 4. The bidirectional mapping marked in Port 4 row of Port Connection Table shown below indicates that packets ingressing at LAN Port 4 can only be forwarded to East Port & those ingressing at East Port can also be forwarded to LAN Port 4 in addition to LAN Port 1.

6 Edit the LAN Port 1 forwarding group so as to include LAN Port 4. This is required in order to forward packets ingressing at LAN Port 1 to LAN Port 4 in addition to East Port.

Page 448: Cambium network ptp 810 series 01 00 user guide

Task 11: Configuring VLAN Chapter 6: Configuration and alignment

6-88 phn-2779_001v000 (Jul 2012)

7 Edit the LAN Port 2 forwarding group so as to include LAN Port 3. This is required in order to forward packets ingressing at LAN Port 2 to LAN Port 3 in addition to West Port.

8 Press the ‘Update’ button to complete the Port Based VLAN configuration.

Configuring MSTPs

The IEEE 802.1s Multiple Spanning Tree Protocol (MSTP) defines an extension to RSTP to further develop the usefulness of virtual LANs (VLANs). This Per-VLAN Multiple Spanning Tree Protocol configures a separate Spanning Tree for each VLAN group and blocks all but one of the possible alternative paths within each Spanning Tree.

To configure MSTPs, select menu option Administration, VLAN Configuration, MSTP Configuration. The MSTP Configuration page is displayed. If no current MSTP instances exist (for example because the user is defining an MSTP instance for the first time), the page is as shown in Figure 133. If at least one MSTP instance has already been created, the page is as shown in Figure 134.

Update the attributes (Table 248). To create a new instance, select Create. To update an instance, select Update. To delete an instance, select Delete.

Page 449: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 11: Configuring VLAN

phn-2779_001v000 (Jul 2012) 6-89

Figure 133 MSTP Configuration page (when no MSTP instances exist)

Figure 134 MSTP Configuration page (when MSTP instances exist)

Page 450: Cambium network ptp 810 series 01 00 user guide

Task 11: Configuring VLAN Chapter 6: Configuration and alignment

6-90 phn-2779_001v000 (Jul 2012)

Table 248 MSTP Configuration attributes

Attribute Meaning

Configuration Name The name identifying the VLAN to MSTI mapping. Bridges must share the name and revision (see below), as well as the VLAN-to-MSTI mapping configuration in order to share spanning trees for MSTI's (Intra-region). The name is at most 32 characters.

Revision The revision of the MSTI configuration named above. This must be an integer between 0 and 65535.

Maximum Hops This defines the initial value of remaining Hops for MSTI information generated at the boundary of an MSTI region. It defines how many bridges a root bridge can distribute its BPDU information to. Valid values are in the range 6 to 40 hops.

Instance In this drop down menu the user can select the STP MSTI bridge instance to configure or can select create to create a new instance.

MST Instance ID When a new instance is to be created this field is used to identify that particular instance.

Instance Priority When a new instance is to be created this field sets the priority of this bridge for that particular instance.

Instance X port priority configuration

Allows port priority configuration which affects the topology of instance X only.

Page 451: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 11: Configuring VLAN

phn-2779_001v000 (Jul 2012) 6-91

Mapping VLANs to MSTP instances

To map VLANs to MSTP instances (MSTIs), select menu option Administration, VLAN Configuration, MSTP Instance VLAN. The MSTP Instance to VLAN Map page is displayed (Figure 135).

A VLAN can only be mapped to one MSTI. Bridges must share the same VLAN-to-MSTI mapping configuration in order to share spanning trees for MSTIs (Intra-region).

Use the Search option to find a specific VLAN ID to be mapped.

Click on the radio buttons to configure the mappings, then select Update.

Figure 135 MSTP Instance to VLAN Map page

Page 452: Cambium network ptp 810 series 01 00 user guide

Task 12: LACP configuration Chapter 6: Configuration and alignment

6-92 phn-2779_001v000 (Jul 2012)

Task 12: LACP configuration

Perform this task to configure a LACP aggregate link using two Gigabit Ethernet ports.

LACP configuration is only available on MMUs with the GigE Master I/O Module installed.

The MMU supports IEEE 802.3ad Link Aggregation Control Protocol (LACP) on the front-panel GigE ports. Within the IEEE 802.3ad standard, LACP provides a method to control the bundling of several physical ports together to form a single logical channel. LACP allows a network device to negotiate an automatic bundling of links by sending LACP packets to the peer (directly connected device that also implements LACP).

Configuring LACP

To configure LACP, select menu option Administration, LACP Configuration. The LACP Configuration page is displayed (Figure 136).

Update the attributes as required (Table 249) and select Update.

To delete an aggregator, set the LACP Mode to ‘Disabled’ on all ports belonging to that aggregator.

Figure 136 LACP Configuration page

Page 453: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 12: LACP configuration

phn-2779_001v000 (Jul 2012) 6-93

Table 249 LACP Configuration attributes

Attribute Meaning

System Priority The global LACP priority value. The range is 1-65535.

LACP System Timeout The administrative LACP timeout.

‘Short’ means a short timeout value.

‘Long’ means a long timeout value.

LACP Mode The administrative LACP control method.

‘Passive’ means that the port prefers not to transmit LACPDUs unless its partner's control value is ‘Active LACP’.

‘Active’ means that the port prefers to participate in the protocol regardless of the partner's control value.

‘Disabled’ means that that LACP is disabled at this port.

Port Priority The LACP priority value for the port. The range is 1-65535.

Port Admin Key The operational Key value assigned to the port. The range is 1-65535. Ports with the same admin key will join one aggregator.

Viewing LACP status

To view the current LACP port status, select LACP Status. The LACP Status page is displayed (Figure 137). This shows the current LACP port status based on the MMU LACP parameter settings in the LACP Configuration page, and the partner device configuration.

Figure 137 LACP Status page

Page 454: Cambium network ptp 810 series 01 00 user guide

Task 13: Connecting link to the network Chapter 6: Configuration and alignment

6-94 phn-2779_001v000 (Jul 2012)

Task 13: Connecting link to the network

Perform this task to connect to the network and set the system clock.

Ensure that the network security requirements are configured before connecting the PTP 810 to the network. Otherwise, security may be compromised. To configure user account or HTTP (SSL), refer to Managing user accounts and security on page 7-27.

This task consists of the following procedures:

• Connecting to the network on page 6-94

• Setting the real-time clock on page 6-95

Connecting to the network

To complete and test the network connections, proceed as follows:

1 Disconnect the local PC from the MMU management port at each MMU.

2 Connect the MMUs to the network equipment using the cables that were prepared in Preparing network connections (1+0 and 2+0 links) on page 5-77.

3 Check that each of the MMUs is reachable from the network management system by opening the web interface to the management agents, or by requesting ICMP echo response packets using the Ping application. The network management system will normally be geographically remote from the site, so it may be necessary to request that this action is completed by co-workers at the management centre. Alternatively, it may be possible to use remote login to the management system.

4 Check that the data network operates correctly across the wireless link. This may be by requesting ICMP echo response packets between hosts in the connected network segments, or by some more structured use of network testing tools.

5 For a 1+1 Hot Standby link:

Initiate a protection switch at one end of the link (as described in Forcing protection switches on page 7-23) and check that the data network operates correctly across the wireless link (as described in the previous step).

Initiate a switch back to the primary ODU.

Repeat for the other end of the link.

Page 455: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 13: Connecting link to the network

phn-2779_001v000 (Jul 2012) 6-95

6 Check that the wireless interface is enabled at both ends, as described in Enabling the ODU on page 7-22.

For a 1+1 Hot Standby link, check that both units are enabled at each end.

7 Select menu option Analysis, Alarms and check that there are no active alarms on any unit. For more information, see Managing alarms on page 7-15.

Setting the real-time clock

The clock supplies accurate date and time information to the MMU. It can be set to run with or without a connection to a network time server (SNTP):

• In the absence of an SNTP server connection, set the clock to run manually. The clock is battery backed and will continue to operate for several days after the MMU is switched off. The battery is installed on the Control Module.

• If an SNTP server connection is available, set the clock to synchronize with the server time at regular intervals.

Setting the real-time clock manually

To set the MMU clock to keep time without connecting to a networked time server, select menu option Administration, Device Information, Set Date & Time. The Set Date & Time page is displayed. Set the SNTP Server Enable attribute to ‘Disabled’ (Figure 138). Review and update the date and time parameters (Table 250), then select Update.

Page 456: Cambium network ptp 810 series 01 00 user guide

Task 13: Connecting link to the network Chapter 6: Configuration and alignment

6-96 phn-2779_001v000 (Jul 2012)

Figure 138 Set Data & Time page (SNTP disabled)

Table 250 Manual clock attributes

Attribute Meaning

SNTP Server Enable SNTP Server Client (Enabled / Disabled).

SNTP Server Address Client Server Address.

Time Zone Time difference from GMT.

Date Format Date format (US, European, Generic).

Date Current terminal date.

Time Current terminal time.

Page 457: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 13: Connecting link to the network

phn-2779_001v000 (Jul 2012) 6-97

Setting the real-time clock to synchronize using SNTP

To set the clock to synchronize with a networked time server, select menu option Administration, Device Information, Set Date & Time. The Set Date & Time page is displayed. Set the SNTP Server Enable attribute to ‘Enabled’ (Figure 139). Review and update the SNTP Server Address, Timezone and Date Format attributes (Table 251), then select Update.

Figure 139 Set Data & Time page (SNTP enabled)

Table 251 SNTP clock attributes

Attribute Meaning

SNTP Server Enable SNTP Server Client (Enabled / Disabled).

SNTP Server Address Client Server Address.

Time Zone Time difference from GMT.

Date Format Date format (US, European, Generic).

Date Current terminal date.

Time Current terminal time.

Page 458: Cambium network ptp 810 series 01 00 user guide

Task 14: Aligning antennas Chapter 6: Configuration and alignment

6-98 phn-2779_001v000 (Jul 2012)

Task 14: Aligning antennas

Do not start antenna alignment until it is safe for the antennas to radiate RF, that is, until the antennas and ODUs have been installed on the masts or poles and no personnel are in front of the antennas.

Before starting alignment, ensure that the installation report contains the required settings, and disable APC.

For background on the alignment process, refer to Introduction to antenna alignment on page 6-98.

Check that the requirements in Prerequisites for alignment on page 6-99 have been met.

For a 1+1 Hot Standby link with two antennas at each end of the link, perform Aligning protected antennas on page 6-99.

For an unprotected link, or for a 1+1 Hot Standby link that uses ODU couplers, perform Aligning a pair of antennas on page 6-100.

Introduction to antenna alignment

Licensed microwave links use parabolic dish antennas which have narrow beam widths ranging from 4.7° down to 0.5°. Beam width depends on antenna gain, larger gain antennas having narrower beam widths. It is most important that all PTP 810 antennas are precisely aligned at the centre of the main beam. If antennas are not aligned at the centre of the main beam, performance will be dramatically reduced.

The alignment process requires the elevation angle (vertical plane) and azimuth angle (horizontal plane) to be adjusted. Antenna assemblies provide a mechanism for independently adjusting in both planes whilst the antenna mounting bracket is securely mounted to the mast. Please refer to the instructions provided with the antenna.

Alignment is achieved by monitoring the receive signal strength indicator (RSSI). This is provided at the ODU BNC socket in the form of a dc voltage (RSSI Voltage). The BNC refresh rate is set to 1 second.

Page 459: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 14: Aligning antennas

phn-2779_001v000 (Jul 2012) 6-99

Prerequisites for alignment

Before starting alignment, confirm the following:

• The antennas, cables and MMUs have been installed at both ends of the link.

• A link planning report is available (for example, from LINKPlanner). It should include predicted RSSI voltage ranges (or received signal levels) and bearings for both ends of the link. If the report specifies predicted receive signal levels (dBm) but not voltages, then convert dBm to volts using the formula or graph in RSSI output on page 4-6.

• Two voltmeters with BNC connectors are available.

• No personnel are in front of the antennas.

Aligning protected antennas

For a 1+1 Hot Standby link with two antennas at each end of the link, align each of the following three pairs by following Aligning a pair of antennas on page 6-100:

1 Align the ‘Tx Hi’ primary antenna to the ‘Tx Lo’ primary antenna. Do not make any further adjustments to the two primary antennas.

2 Align the ‘Tx Hi’ secondary antenna to the (now fixed) ‘Tx Lo’ primary antenna.

3 Align the ‘Tx Lo’ secondary antenna to the (now fixed) ‘Tx Hi’ primary antenna.

Step 3 can be performed before step 2, if preferred.

Aligning dual-polar antennas

Perform alignment with either the Horizontal units muted or the Vertical units muted. Take RSSI readings on the unmated units. After alignment, check that the difference in receive power is within tolerance specified in the link planning report.

For more information, refer to the antenna manufacturer’s instructions.

Page 460: Cambium network ptp 810 series 01 00 user guide

Task 14: Aligning antennas Chapter 6: Configuration and alignment

6-100 phn-2779_001v000 (Jul 2012)

Aligning a pair of antennas

Connect the MMUs to a management PC and open the web interfaces at both ends of the link. For more information, see Connecting to the PC and powering up on page 6-7 and Logging into the web interface on page 6-7.

Antennas are aligned by monitoring ODU output voltage and receive power.

Align each pair of antennas by using Step 5, Step 6 and Step 7 of the Installation Wizard, as described in the following procedures:

• Starting antenna alignment on page 6-100

• Aligning antennas on page 6-100

• Completing alignment on page 6-103

Starting antenna alignment

The MMU does not provide a separate mode of operation for antenna alignment. Perform antenna alignment while the MMU is in an operational mode. At both ends of the link, check that the correct IDU Operational Mode and ODU Operational Mode have been configured. If necessary, select menu option Link Configuration, Radio Link, Link Configuration and click through the steps of the Link Configuration Wizard.

Aligning antennas

During the alignment process, ensure that antenna waveguide and coaxial components are not strained beyond their minimum bend radii.

Preparing for alignment

To prepare the antennas for alignment, proceed as follows at both link ends:

1 Using the instructions provided with the antenna, set the elevation and azimuth adjustment mechanisms to the centre of the range.

2 Using the instructions provided with the antenna, adjust the position of the antenna mounting bracket such that the antenna is pointing at the other end of the link. Use a compass and the bearing provided by the planning report.

3 Once the antenna is in position, resecure the mounting bracket.

Page 461: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 14: Aligning antennas

phn-2779_001v000 (Jul 2012) 6-101

4 Connect a suitable voltmeter to the RSSI connector. Figure 15 shows the location of this connector for the ODU. Connect the center of the RSSI connector to the positive terminal of the voltmeter.

5 Use the voltmeter to monitor the RSSI voltage during alignment.

Aligning one end

Align the antenna at one end of the link while keeping the antenna at the other end of the link stationary.

To find the correct elevation and azimuth angles at one end, proceed as follows:

1 Perform a complete sweep of the elevation range of the antenna by adjusting the elevation angle incrementally. The extent of the sweep depends upon antenna gain. Measure RSSI voltage at each point in the sweep.

2 The resulting plot of voltage against elevation should be symmetrical. Record the elevation angle that appears to be at the axis of symmetry, as this is likely to be the correct angle for aligning with the other antenna (Figure 140).

Figure 140 shows the axis of symmetry occurring at a voltage ‘peak’. However, it is possible for the axis of symmetry (and therefore the correct elevation angle) to occur at a voltage ‘trough’ (Figure 141).

3 Set the elevation angle to the axis of symmetry, as identified in the plot.

4 Perform a complete sweep of the azimuth range of the antenna and record the resulting plot of voltage against azimuth.

5 Set azimuth angle to the centre of the range over which the maximum RSSI voltage is recorded.

Page 462: Cambium network ptp 810 series 01 00 user guide

Task 14: Aligning antennas Chapter 6: Configuration and alignment

6-102 phn-2779_001v000 (Jul 2012)

Figure 140 Symmetrical relationship between voltage and alignment

Figure 141 Typical RSSI voltage peaks and troughs

Page 463: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 14: Aligning antennas

phn-2779_001v000 (Jul 2012) 6-103

Aligning the other end

Repeat the above procedure at the other end of the link.

Record the RSSI voltage at both ends of the link. If the voltage at either end of the link is not in the range predicted by the planning report, repeat alignment until this is the case.

Post-alignment actions

In a 1+1 Hot Standby link, the tolerances in the ODUs may result in the Receive Power delta between the primary and secondary ODUs at same end of the link being different from the delta predicted by the network designer. Configurations using a single antenna may have up to ±5 dB additional delta when compared with the design value. Where separate antennas are used, the tolerances may increase if either path incurs any Excess Path Loss.

When alignment is complete at both ends, proceed as follows:

1 At each end of the link in turn, lock off and tighten all the adjustment bolts as per the instructions provided with the antenna and check that the RSSI voltage does not change. If it does change, repeat alignment for the affected end.

2 Check that the following requirements are met:

a. RSSI voltage at both ends is within the range predicted by the planning report.

b. East /West Modem status in the Status Panel is ‘Locked’.

c. RSL at both ends of the link is within the range predicted by the planning report.

3 If any of the above requirements are not met, antenna alignment is not complete; refer to troubleshooting section Trouble establishing a wireless link on page 8-8.

Completing alignment

The installation process has been completed. The transmitter is now enabled. To review the current link status, look at the Status Panel displayed on the right side of the GUI.

Page 464: Cambium network ptp 810 series 01 00 user guide

Task 15: Reviewing configuration and performance Chapter 6: Configuration and alignment

6-104 phn-2779_001v000 (Jul 2012)

Task 15: Reviewing configuration and performance

Perform this task after antenna alignment is complete.

This task consists of the following procedures:

• Reviewing system configuration attributes on page 6-104

• Monitoring link performance on page 6-105

Reviewing system configuration attributes

To review and update the system configuration of a PTP 810 link, select menu option Link Configuration, Configuration Summary. The Summary of Configurations page is displayed (Figure 142). Review the configuration parameters. Update any incorrect configuration parameters by following the procedures in this chapter. Save a backup copy of the link configuration.

Figure 142 Summary of Configuration page

Page 465: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Task 15: Reviewing configuration and performance

phn-2779_001v000 (Jul 2012) 6-105

Monitoring link performance

For at least one hour of operation after alignment is complete, the link should be monitored to check that it is achieving predicted levels of performance.

To check performance, view the Status Panel displayed on the right side of the GUI. Monitor the following parameters:

• Tx Power

• Far End Tx Power

• RSL

• Far End RSL

• Signal/Noise

• Alarm Status

• Modem Status

Use the System Status panel (Figure 146 and Figure 147) to verify that the Modem(s) are ‘Locked’ and that the RSL, Far End RSL and Signal/Noise parameters display a “green” bar indicating acceptable link margin. PTP LINKPlanner provides a prediction of the RSL in the form of an installation report.

Page 466: Cambium network ptp 810 series 01 00 user guide

Task 15: Reviewing configuration and performance Chapter 6: Configuration and alignment

6-106 phn-2779_001v000 (Jul 2012)

Page 467: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide

phn-2779_001v000 (Jul 2012) 7-1

Chapter 7: Operation

This chapter describes how to operate a PTP 810 link.

The following topics are described in this chapter:

• Web-based management on page 7-2 describes the layout and the main menu options of the PTP 810 web-based management interface.

• Managing alarms and events on page 7-15 describes how to manage PTP 810 system alarms and events.

• Disabling, enabling, muting and unmuting the ODU on page 7-21 describes how to disable, enable, mute and unmute an ODU.

• Managing 1+1 Hot Standby links on page 7-23 describes how to manage 1+1 links, and how to force protection switches and inhibit protection switching.

• Managing 2+0 Co-Polar, Cross-Polar & XPIC links on page 7-25 describes how to manage 2+0 Cross-Polar, 2+0 Co-Polar and 2+0 XPIC aggregation links.

• Managing user accounts and security on page 7-27 describes how to manage user accounts, and how to configure the unit to operate in HTTPS (SSL) secure mode.

• Managing performance on page 7-31 describes how to view and manage PTP 810 system statistics and diagnostics.

• Saving, restoring and rebooting on page 7-51 describe how to save and restore the system configuration, and how to reboot the unit.

• Restoring system defaults on page 7-54 describes how to restore the MMU system default parameters.

• Viewing device information on page 7-57 describes how to view MMU general device and serial number information, and how to modify MMU device name related information.

• Upgrading the system on page 7-60 describes how to enter an authorization key to increase data capacity or implement XPIC, and how to install a new software version.

• Removing and installing modules on page 7-67 describes how to remove and install the individual MMU modules.

Page 468: Cambium network ptp 810 series 01 00 user guide

Web-based management Chapter 7: Operation

7-2 phn-2779_001v000 (Jul 2012)

Web-based management

This section describes the layout and the main menu options of the PTP 810 web-based management interface.

Accessing the web interface

The web interface is best viewed using a screen resolution of at least 1024 x 768 pixels. The web pages have been tested with Internet Explorer 7, Internet Explorer 8, Firefox 3 and Firefox 3.5. Other browsers have not been tested. The web interface also requires the use of Sun Java Runtime Environment 5.0 or above.

To access the web interface, type the IP address of the unit into the browser address bar and press ENTER. A popup window (Figure 143) will prompt for a user name and password. Enter a user name and password then select OK. The web interface initial is displayed in its initial state (Figure 144). Select View Status Panel.

Figure 143 System Administration Login page

Page 469: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Web-based management

phn-2779_001v000 (Jul 2012) 7-3

Figure 144 Web interface without status panel

Layout of the web interface

The web interface consists of three panels (Figure 145). The navigation tree menu is displayed in the left panel of the page. The specific page selected by using the menu is displayed in the center panel of the page. The status panel is displayed in the right panel of the page.

The menu selections used for configuration, along with their corresponding center panel pages, are described in the tasks that follow in this chapter.

Page 470: Cambium network ptp 810 series 01 00 user guide

Web-based management Chapter 7: Operation

7-4 phn-2779_001v000 (Jul 2012)

Figure 145 Web interface with status panel

Viewing the system status

To view the system status, select menu option Home. In addition, be sure that the Status Panel is visible by clicking on the “View Status Panel” text box displayed in the right panel of the web interface.

The Home page displays the IP address and name of the MMU along with the system uptime (Figure 145). The Status Panel gives the user a view of the operation of the PTP 810 from the wireless link perspective (Figure 146).

The content of the Status Panel will display either one or two modem links depending upon the configuration of the PTP 810. Figure 146 and Figure 147 contain examples of various configurations. The status panel page provides the modem and alarm status of the MMU (Table 252).

Page 471: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Web-based management

phn-2779_001v000 (Jul 2012) 7-5

Figure 146 Status panel examples (Standard and 2+0 XPIC)

Standard

2+0 XPIC

Page 472: Cambium network ptp 810 series 01 00 user guide

Web-based management Chapter 7: Operation

7-6 phn-2779_001v000 (Jul 2012)

Figure 147 Status panel examples (Protected Non-diversity, East/East and East/West)

Protected Non-diversity

East/East

East/West

Page 473: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Web-based management

phn-2779_001v000 (Jul 2012) 7-7

Table 252 Status panel modem and alarm status indicators

Indicator Meaning

Alarm Alarm Status:

Red indicates that one or more alarms are outstanding.

Green indicates that no alarms are outstanding.

Click on the colored disk to view the Active Alarms Page.

MODEM, EAST MODEM, WEST MODEM

MMU modem configuration:

‘MODEM’ is displayed when the standard ODU operational mode is configured.

‘EAST MODEM’ and ‘WEST MODEM’ are displayed when ODU operational modes using two modems are configured.

Locked, Unlocked, NA Status of the modem(s):

‘Locked’ means that the link is established (up).

‘Unlocked’ means that the link is not established (down).

‘NA’ means that the modem is inactive.

Transmitter ACTIVE, STANDBY, OFF, ON

Current status of the ODU:

‘ACTIVE’ means that the ODU transmitter and receiver are both on.

‘STANDBY’ means that the ODU Transmitter is off but the receiver is on.

‘OFF’ means that the ODU is off.

‘ON’ means that the ODU is on but not configured.

TX Power Transmitting power of the local ODU in dBm.

Far End TX Power Transmitting power of the remote ODU in dBm.

RSL Received signal level of the local ODU in dBm.

Far End RSL Received signal level of the remote ODU in dBm.

Signal/Noise Signal noise value in dB. If the modem is unlocked, this is displayed as ‘N/A’. The upper limit of 25.5 dB is a good level.

Tx Freq and Rx Freq Transmit frequency and receive frequency in GHz. When East and West modems are configured, Tx Freq and Rx Freq are displayed for both modems.

Mode, East mode, West mode

Modulation mode of the link from a single modem (Modem) or from two modems (East mode and West mode).

Page 474: Cambium network ptp 810 series 01 00 user guide

Web-based management Chapter 7: Operation

7-8 phn-2779_001v000 (Jul 2012)

Indicator Meaning

Local IP IP address of the local MMU.

Local Host Product name of the local MMU (‘PTP810’).

Remote IP IP address of the remote MMU.

Remote Host Product name of the remote MMU (‘PTP810’).

Page 475: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Web-based management

phn-2779_001v000 (Jul 2012) 7-9

Using the menu options

All web pages contain the menu navigation bar on the left hand side (Figure 148). The menu is used to navigate to other web pages.

Figure 148 Menu bar

Page 476: Cambium network ptp 810 series 01 00 user guide

Web-based management Chapter 7: Operation

7-10 phn-2779_001v000 (Jul 2012)

Table 253 lists the procedures that may be performed from each menu option. Many of these procedures are part of the initial configuration and alignment process described in Chapter 6: Configuration and alignment. Some of the menu options are hardware module or system configuration dependent and won’t be visible in the menu of a MMU that does not have a specific hardware module installed or system configuration deployed.

Table 253 Procedures performed from each menu option

Menu Option Description Task or procedure

Home View Starting Information and Status Panel

Accessing the web interface on page 7-2

Viewing the system status on page 7-4

Administration Network Configuration General Configure general network

related parameters Configuring the IP interface on page 6-14

SNMP Configure SNMP related parameters

Configuring SNMP agent on page 6-54

Syslog Server Configure Syslog IP Address and Syslog Facility

Configuring system logging (syslog) on page 6-62

E‐mail Configure E-mail related parameters

Configuring generation of diagnostics alarms on page 6-57

Ethernet NMS Configure Ethernet NMS related parameters

Configuring Ethernet network management on page 6-21

Ethernet Payload Configure Ethernet Payload related parameters

Configuring Ethernet payload on page 6-16

VLAN Configuration Global VLAN Configuration Configure general VLAN

related parameters Configuring global VLAN options on page 6-73

Static VLAN Configuration Configure Static VLAN Table Configuring static VLANs on page 6-75

Port Based Forwarding Mode Configure Port Based Forwarding groups

Configuring port based VLANs on page 6-77

MSTP Configuration Configure multiple spanning trees

Configuring MSTPs on page 6-88

Page 477: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Web-based management

phn-2779_001v000 (Jul 2012) 7-11

Menu Option Description Task or procedure

MSTP Instance VLAN Map Configure multiple spanning tree VLAN mapping

Mapping VLANs to MSTP instances on page 6-91

LACP Configuration Configure LACP related parameters

Configuring LACP on page 6-92

QoS Configuration Global Settings Configure general QoS

related parameters Setting QoS priority method on page 6-63

Port Priority Configure frame priority map Setting QoS port priorities on page 6-66

VLAN p‐bit Tag Priority Configure 802.1Q tag priority map

Setting QoS VLAN p-bit tag priorities on page 6-68

DiffServ Priority Configure DiffServ DSCP priority map

Setting QoS DiffServ DSCP priorities on page 6-69

Switch Priority Configure QoS Switch Priority to Tx Priority Queue map

Setting QoS switch priorities on page 6-71

Serial Configuration Configure data baud rate for RS-232 serial port

Configuring Serial Port on page 6-15

Security Configuration Configure HTTP Access and CLI Access security protection (SSL/SSH)

Configuring HTTP (SSL) on page 7-30

Device Information General Display model number and

active application version General device information on page 7-57

Device Names Modify terminal device information

Device name and owner information on page 7-58

Set Date and Time Set date, date format, time, time zone

Setting the real-time clock on page 6-95

Serial Numbers Display all module names, part numbers, serial numbers

Serial number information on page 7-58

Maintenance Reprogramming Used to reprogram the

software images. Installing new software versions on page 7-63

Add User Add users to the MMU with associated password

Creating user accounts on page 7-27

Page 478: Cambium network ptp 810 series 01 00 user guide

Web-based management Chapter 7: Operation

7-12 phn-2779_001v000 (Jul 2012)

Menu Option Description Task or procedure

Delete User Delete users from the MMU or change password of users

Deleting user accounts on page 7-28

View Event Log View event log of the MMU and clear it when required

Viewing event log of MMU access on page 7-29

Reboot Reboot the MMU or selected modules

Rebooting on page 7-53

Restore Configuration Restore a saved configuration or store existing configuration

Saving the system configuration on page 7-51

Restoring the system configuration on page 7-52

Restore Defaults Restore system defaults on MMU

Restoring system defaults on page 7-54

Link Configuration Authorization Enter an Authorization Key Entering an authorization key

on page 7-60

Configuration Summary View system configuration summary

Viewing the configuration summary on page 6-24

Radio Link APC Configuration Configure APC parameters Configuring APC and coupler

loss compensation on page 6-34

ODU Tx Mute Config Configure ODU Transmit Mute parameter on un-protected links

Configuring the ODU on page 6-33

Link Configuration Configure link operating mode and modulation mode

Viewing the configuration summary on page 6-24

ODU Configuration Configure enable/disable and mute/unmute of ODUs

Configuring the ODU on page 6-33

Disabling, enabling, muting and unmuting the ODU on page 7-21

Protection Configuration Configure protection parameters

Configuring protection on page 6-50

Managing 1+1 Hot Standby links on page 7-23

Data Link E1/T1 Channel Map Modify E1/T1 channel map

settings Configuring channel mapping on page 6-38

Page 479: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Web-based management

phn-2779_001v000 (Jul 2012) 7-13

Menu Option Description Task or procedure

E1/T1 Ports Configure settings of physical E1/T1 channels

Configuring E1/T1 ports on page 6-42

E1/T1 Protection Switching Configure protection switching priority of E1/T1 channels

Configuring E1/T1 protection switching on page 6-45

Orderwire Configure DOW operating mode

Configuring orderwire on page 6-48

Analysis Alarms Active Displays active alarms

information Managing alarms on page 7-15

Alarm Configuration Configure alarm attributes Configuring generation of diagnostics alarms on page 6-57

History Displays alarm history information

Managing alarms on page 7-15

Threshold Configure alarm thresholds related to temperature, SNR, Min. RSL

Configuring alarm thresholds on page 6-59

Graphs RSL Graph East/West RSL Viewing wireless link

performance on page 7-31

Signal/Noise Graph East/West SNR Viewing wireless link performance on page 7-31

Tx Power Graph East/West Tx Power Viewing wireless link performance on page 7-31

RF Link Performance Graph East/West RF error seconds

Viewing wireless link performance on page 7-31

Equalizer Taps Graph East/West tap indices Viewing wireless link performance on page 7-31

Constellation Graph East/West modulation constellation

Viewing wireless link performance on page 7-31

Temperature Graph East/West ODU and MMU temperature

Viewing wireless link performance on page 7-31

Ethernet Switch NMS Statistics Data switch statistics Viewing Ethernet switch

statistics on page 7-42

Page 480: Cambium network ptp 810 series 01 00 user guide

Web-based management Chapter 7: Operation

7-14 phn-2779_001v000 (Jul 2012)

Menu Option Description Task or procedure

Payload Statistics NMS switch statistics Viewing Ethernet switch statistics on page 7-42

NMS STP Status NMS spanning tree status Viewing Ethernet switch statistics on page 7-42

Payload STP Status Payload spanning tree status Viewing Ethernet switch statistics on page 7-42

BERT Mode Enable BERT testing across a link

BERT mode on page 8-18

Loopback Enable loopback testing across a link

Performing a loopback test on page 8-15

Logout Logout of MMU GUI Logging out on page 7-14

Logging out

To maintain security, always log out at the end of a session by selecting menu option Logout. In the case of Internet Explorer, the logout link will close the browser. For other browsers, the user may have to close the browser manually.

Page 481: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Managing alarms and events

phn-2779_001v000 (Jul 2012) 7-15

Managing alarms and events

This section describes how to manage PTP 810 system alarms and events.

This section contains the following procedures:

• Managing alarms on page 7-15.

• Managing SNMP traps on page 7-20.

• Managing event notification messages on page 7-20.

Managing alarms

Whenever system alarms are outstanding, the Alarm status LED at the top of the Status Panel turns red. The Status Panel and its Alarm status LED are visible from all web pages. Click on the Alarm status LED (or menu option Analysis, Alarms, Active) to view the active alarms. If the Alarm status LED turns green, it indicates that the outstanding alarms have been cleared. A change of state in most alarms generates an SNMP trap.

The alarm configuration procedure is described in Task 8: Configuring alarms and messages on page 6-57.

The example in Figure 149 shows the Alarm status LED in the Status Panel set to red and the Active Alarms displayed in the center panel.

Figure 149 Active Alarms page

Page 482: Cambium network ptp 810 series 01 00 user guide

Managing alarms and events Chapter 7: Operation

7-16 phn-2779_001v000 (Jul 2012)

The list of alarms and their descriptions are provided in Alarms on page V. This list of alarms is in the form of a table that includes five columns of status information associated with each alarm. This status information is as follows:

• Affected Component – The name of the MMU module card affected by the alarm, for example Modem Upper (West Modem), Modem Lower (East Modem), Controller, Master IO, Expansion IO or Power Supply; or the system component affected by the alarm. for example IDU, ODU, or Link Partner IDU.

• Description – The description of the event that triggered the alarm.

• LED to RED – The name of the module (if any) whose front panel status LED will turn red when the alarm is activated. The Controller, Master I/O, Expansion I/O, Power Supply and Modem cards all have a front panel status LED.

• Alarm Code – The number of the alarm code (if any) that will be flashed by the front panel status LED of the Controller card (see Controller card status LED on page 7-16).

• Severity – The relative severity of the alarm code. The severity is categorized as either Info, Major or Critical.

Controller card status LED

The controller card status LED is the primary front panel indicator of alarms. An alarm is generated when a specific condition is identified and is cleared when the specific condition is no longer detected. The status alarm LED of the controller card can operate in two ways:

• Solid on

• Flashing to indicate an alarm code

Alarms on page V provides a complete list of alarms and indicates whether the alarm is solid or will flash a code. When an alarm with a code is posted, the following sequence of events occurs:

1. The controller status LED turns orange for 5 seconds.

2. The controller status LED turns off for 5 seconds.

3. The controller status LED flashes orange the number of times specified by the first digit of the alarm code.

4. The controller status LED turns off for 3 seconds.

5. The controller status LED flashes orange the number of times specified by the second digit of the alarm code.

Steps 2-5 are repeated for each alarm posted. The entire process is repeated as long as the alarms are still posted.

Page 483: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Managing alarms and events

phn-2779_001v000 (Jul 2012) 7-17

Modem card status LED

The modem card status LED indicates the modem status as described in Table 254.

Table 254 Modem card status LED

LED Status

Green solid Active Locked Link

Orange solid Standby Locked Link (1+1 Non-Diversity Only)

Green blink Low SNR

Orange blink Unlocked

Red blink ODU –48 V power is disabled

Red solid ODU Power Fault. Occurs when the –48 V to the Modem Module is low or excessive current is being drawn from the –48 V. In either case, the –48 V will be disabled by the hardware.

Modem Hardware Fault. Occurs when any of the power-on self tests failed or IF Power Fault or Digital Power Fault detected during normal operation.

Alarm History

The Alarm History page is shown in Figure 150. To view the alarm history, select menu option Analysis, Alarms, History. This page lists alarms that have occurred and their description, status and time. A maximum of 300 alarms can be displayed. If the alarm history exceeds 300 alarms, the oldest alarms will be overwritten. The MMU stores the latest 200 alarms in non-volatile memory.

The following items are displayed on this page:

• Description – Displays the description (name) of the alarm.

• Status – Displays the status of the alarm (set/reset).

• Time – Displays the time at which this particular alarm was set/reset.

To clear the alarm history records, select Clear History.

To export the alarm history to a local Alarm History.csv file, select Export to CSV.

Page 484: Cambium network ptp 810 series 01 00 user guide

Managing alarms and events Chapter 7: Operation

7-18 phn-2779_001v000 (Jul 2012)

Figure 150 Alarm History page

ODU alarms

In the case of an ODU Fault Lower, ODU Fault Upper, or a Protection Switch alarm resulting from an ODU failure condition, the Active Alarms and Alarm History messages will indicate the fault code from the ODU. Text describing the alarm type from the ODU library will be added to the alarm text in the Active Alarms and Alarm History. Table 255 lists the ODU alarms that are reported by the MMU along with the associated fault code and description. These alarms and fault codes are common to both ODU-A and ODU-B.

Table 255 ODU Alarms

ODU Alarm Fault Code Description

Rx Synth Lock

00 This indicates a failure of the Rx RF synthesizer in the ODU.

Tx Synth Lock

01 This indicates a failure of the Tx RF synthesizer in the ODU.

IF Synth Lock 03 This indicates a failure of the IF synthesizer in the ODU.

Lockout Alarm

05 The connected device is not a Cambium branded ODU.

Page 485: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Managing alarms and events

phn-2779_001v000 (Jul 2012) 7-19

There are additional ODU alarms used to report “degraded” ODU status that are not reported by the MMU. These alarms include: 1) the Cable Alarm used to indicate that the IF signal strength has fallen outside the target voltage range, 2) the Cable Attenuator Adjustment alarm which is active when the ODU is executing the cable compensation procedure (typically on power-up or “hard” reset), and 3) the Tx Power Degraded alarm which is triggered if the Tx Output power has fallen more than 3 dBm below the commanded power.

XPIC alarms

Table 256 describes the MMU alarms that are specific to XPIC.

Table 256 XPIC Alarms

Alarm Name Alarm Description

Signal/XPI Threshold Low Lower

The XPIC signal-to-cross polarization interference ratio is below the minimum operational level of the link as set during configuration (see Configuring alarm thresholds on page 6-59). ‘Upper’ / ‘Lower’ is an indication of the modem card location in the MMU chassis. Fault detection is done via modem status polling, comparing user configured threshold value with threshold value in configuration table. Polling interval 5 seconds.

Signal/XPI Threshold Low Upper

XPIC Unlock Lower

and

XPIC Unlock Upper

XPIC is not providing cancellation, that is, XPIC has lost phase lock with the XPI signal. If this alarm is triggered when the Signal/XPI ratio is greater than 25 dB, the cross-polar interfering signal is too low to need to be cancelled and will not affect the operation of the link. Under this condition the alarm should be treated as informational only. Cancelling of the XPI signal usually occurs when the Signal/XPI ratio is between 10 and 25 dB. However, if the signals are impaired, for example due to high phase noise, then the alarm could be triggered, indicating a problem on the link. Equally, when the Signal/XPI ratio is below 10 dB, there is unlikely to be sufficient discrimination for effective cancellation and the alarm indicates a problem on the link. The Signal/XPI ratio is included in the Signal/Noise graph (Figure 158).

‘Upper’ / ‘Lower’ is an indication of the modem card location in the MMU chassis. Fault detection is done via modem status polling.

XPIC Cable Interface Error Lower

XPIC Loss of Link status of the modem card has unlocked indicating that the intermodem hi-speed cable interface has

Page 486: Cambium network ptp 810 series 01 00 user guide

Managing alarms and events Chapter 7: Operation

7-20 phn-2779_001v000 (Jul 2012)

Alarm Name Alarm Description

XPIC Cable Interface Error Upper

been disconnected. ‘Upper’ / ‘Lower’ is an indication of the modem card location in the MMU chassis.

West Modem XPIC FPGA Not Available

This alarm is raised when the ODU operational mode is 2+0 XPIC and the Active Image in the Modem West FPGA is not the XPIC FPGA.

East Modem XPIC FPGA Not Available

This alarm is raised when the ODU operational mode is 2+0 XPIC and the Active Image in the Modem East FPGA is not the XPIC FPGA.

Managing SNMP traps

The PTP 810 supports SNMP v2 and SNMP v1 remote management of traps. To configure SNMP traps, refer to Task 7: Setting up SNMP agent on page 6-54.

View SNMP traps using the IP address of one of the configured trap managers.

Managing event notification messages

When system logging is enabled, log entries are transmitted to a syslog server. System logging (syslog) on page 1-54 describes the system logging feature.

To configure system logging, refer to Task 9: Configuring syslog on page 6-62.

To enable system logging, select menu option Administration, Network Configuration, Syslog Server. The Syslog Configuration page is displayed (Figure 120).

The MMU will send syslog information to the syslog server where it can be accessed for viewing.

Page 487: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Disabling, enabling, muting and unmuting the ODU

phn-2779_001v000 (Jul 2012) 7-21

Disabling, enabling, muting and unmuting the ODU

This section describes how to disable, enable, mute and unmute an ODU.

Disabling the ODU

‘Disabling’ an ODU means turning off power to the ODU. With no power, both the transmitter and the receiver of the ODU are disabled. Do this before starting maintenance work near the antenna.

To disable an ODU, select menu option Link Configuration, Radio Link, ODU Configuration. The ODU Configuration page is displayed (Figure 151). Select the ODU (East / West) to be disabled, then select Disable ODU. The power to the selected ODU is disabled and the Transmitter Status in the Status Panel displays “OFF”.

Figure 151 ODU Configuration page

In a 1+1 Hot Standby link, disable protection switchover before disabling wireless transmission (see Enabling and disabling fault protection on page 7-24). Otherwise, a switchover to the inactive unit may occur when the wireless interface is muted. Re-enable protection switchover after wireless transmission is re-enabled.

Page 488: Cambium network ptp 810 series 01 00 user guide

Disabling, enabling, muting and unmuting the ODU Chapter 7: Operation

7-22 phn-2779_001v000 (Jul 2012)

Enabling the ODU

‘Enabling’ an ODU means turning on power to a disabled ODU.

To enable an ODU, select menu option Link Configuration, Radio Link, ODU Configuration. The ODU Configuration page is displayed (Figure 151). Select the ODU (East / West) to be enabled, then select Enable ODU button. The power to the selected ODU is enabled and the Transmitter Status in the Status Panel no longer displays “OFF”.

Muting the ODU

‘Muting’ an ODU means that the ODU transmitter is disabled but the ODU receiver is still enabled. This is used in 1+1 HSB protection where one ODU is actively transmitting while the ODU used for protection has its transmitter muted, but still has its receiver active for configurations like spatial diversity.

To mute an ODU (when MMU is in 1+1 HSB operation), select menu option Link Configuration, Radio Link, ODU Configuration. The ODU Configuration page is displayed (Figure 151). Select the ODU (East / West) to be muted, then select Mute ODU. The selected ODU is muted and the Transmitter Status in the Status Panel displays “STANDBY”.

Unmuting the ODU

‘Unmuting’ an ODU means enabling the transmitter at a muted ODU.

To unmute an ODU, select menu option Link Configuration, Radio Link, ODU Configuration. The ODU Configuration page is displayed (Figure 151). Select the ODU (East / West) to be unmuted, then select Unmute ODU. The selected ODU is unmuted and the Transmitter Status in the Status Panel no longer displays “STANDBY”.

Page 489: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Managing 1+1 Hot Standby links

phn-2779_001v000 (Jul 2012) 7-23

Managing 1+1 Hot Standby links

This section describes how to manage 1+1 Hot Standby links.

Forcing protection switches

Protection switches may be forced for a variety of reasons, for example:

• During maintenance operations.

• During software or hardware upgrades.

• To investigate error conditions that have not resulted in a protection switch.

• To confirm that the inactive unit remains fully functional.

To avoid loss of service, force protection switches only if link planning indicates that the unit(s) are capable of operating a satisfactory link.

After a protection switch has been initiated, if work is to be carried out on the newly inactive unit, ensure that fault protection is temporarily disabled until the activity is completed.

To force a protection switch, select menu option Link Configuration, Radio Link, Protection Configuration. Click on the Switch Transmitting ODU button on the Protection Configuration page (Figure 115). Monitor the Status Panel to verify that the “ACTIVE” ODU switches to “STANDBY” and the “STANDBY” ODU switches to “ACTIVE”.

Enabling revertive and non-revertive switching

For a 1+1 Hot Standby link, either revertive or non-revertive protection switching must be enabled. For non-revertive switching, the failed modem/ODU is marked as failed, powered down, and re-powered every three minutes to check for failure. If a failed alarm condition still exists, the modem/ODU is disabled again for three minutes. If it no longer fails, the modem/ODU is set for standby operation. For revertive switching, the failed modem/ODU pair is put directly into standby. Automatic reversion to the originally active modem is not supported.

To enable non-revertive protection switching, select menu option Link Configuration, Radio Link, Protection Configuration. Select the Enabled radio button of the 'Power down ODU after switch' parameter. To enable revertive protection switching, select the Disabled radio button of the 'Power down ODU after switch' parameter.

Page 490: Cambium network ptp 810 series 01 00 user guide

Managing 1+1 Hot Standby links Chapter 7: Operation

7-24 phn-2779_001v000 (Jul 2012)

Enabling and disabling fault protection

The Protection Configuration page (Figure 115) can be used to enable or disable fault protection switching during the operation of the link. When switching is disabled, a fault will not cause a protection switch, but the user may still manually switch. This feature is intended to be used during maintenance actions where the user does not wish faults to change which MMU/ODU is active.

This may be a required state with Spatial Diversity to prevent transmission through a non-compliant diverse antenna.

To enable and disable fault protection, select menu option Link Configuration, Radio Link, Protection Configuration. To enable or disable fault protection switching at the local end of the link, select the Enabled or Disabled radio button of the APS Switch parameter. To enable or disable fault protection switching at the remote end of the link, select the Enabled or Disabled radio button of the Update Remote APS Switch parameter.

To enable or disable protection switching triggered by remote end Lock Status information, select the Enabled or Disabled radio button of the Remote Transmitter Switching parameter.

Selecting preferred transmitting ODU

The Protection Configuration page (Figure 105) can be used to select the East or West ODU as the preferred transmitting ODU. This setting is used, for example, when an asymmetric coupler is being used in the antenna configuration. The ODU associated with the path in the coupler that has the lower loss is typically selected as the preferred ODU.

To configure the preferred ODU, select menu option Link Configuration, Radio Link, Protection Configuration. Select the East or West radio button of the Preferred ODU parameter. Press the Update button to reconfigure the preferred ODU.

Page 491: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Managing 2+0 Co-Polar, Cross-Polar & XPIC links

phn-2779_001v000 (Jul 2012) 7-25

Managing 2+0 Co-Polar, Cross-Polar & XPIC links

This section describes how to manage 2+0 Co-Polar, 2+0 Cross-Polar, and 2+0 XPIC links. In all three of these link configurations, two wireless links are used to transmit E1/T1 channels and Ethernet data between the MMUs located at the end points of the link. Channel mapping is used to divide the E1/T1 traffic between both wireless links. The operation of these links with Ethernet payload depends on the Master I/O card that is deployed.

GigE Master I/O operation

When a GigE Master I/O module is deployed, the MMU can be configured to support either Segregation or Link Aggregation of the Ethernet payload. Segregation is the default Ethernet payload configuration.

Segregation

In Segregation, the MMU’s front panel GigE ports are grouped into two groups of two ports. There are two methods for segregation configuration. The first method is to use RSTP. Select menu option Administration, Network Configuration, Ethernet Payload. Using the Spanning Tree Mode pulldown menu, select IEEE 802.1w (RSTP) (see Configuring Ethernet payload on page 6-16). Traffic from group 1 (port 1 and port 2) is sent across the “East” radio link and traffic from group 2 (port 3 and port 4) is sent across the “West” radio link. The second method is to use port forwarding. Select menu option Administration, VLAN Configuration, Port Based Forwarding and select the appropriate checkboxes to perform port based VLAN configuration (see Configuring port based VLANs on page 6-77).

Link Aggregation

In Link Aggregation, the MMU’s front panel GigE ports share the aggregate bandwidth. The MMU’s internal Layer 2 Ethernet switch load balances packets between the two radio links. To enable Link Aggregation select menu option Administration, Network Configuration, Ethernet Payload. Using the Ethernet Trunk Mode pulldown menu, select 2+0 Trunk Port Aggregation (see Configuring Ethernet payload on page 6-16).

When 2+0 Trunk Port Aggregation is enabled, the MMU’s VLAN configuration features are disabled. However, the MMU does provide transparent forwarding of VLAN tagged and untagged traffic, including traffic forwarding between front panel ports.

Page 492: Cambium network ptp 810 series 01 00 user guide

Managing 2+0 Co-Polar, Cross-Polar & XPIC links Chapter 7: Operation

7-26 phn-2779_001v000 (Jul 2012)

Standard Master I/O operation

The Standard Master I/O module does not support Link Aggregation as described above for the GigE Master I/O module. The Standard Master I/O module includes two front panel Fast Ethernet ports which can be configured to support Segregation using port based forwarding or MSTP/RSTP. The traffic from one port is sent over the “East” link and the traffic from the other port is sent over the “West” link. To perform port based forwarding select menu option Administration, VLAN Configuration, Port Based Forwarding and select the appropriate checkboxes (see Configuring port based VLANs on page 6-77). To perform MSTP select menu option Administration, VLAN Configuration, MSTP Configuration and input the required configuration parameters (see Configuring MSTPs on page 6-88).

Link outage considerations

In the event of a failure of a 2+0 Co-Polar or 2+0 Cross-Polar link, maximum throughput will be reduced by one-half. In the case of Link Aggregation, the Ethernet traffic on the failed link will be automatically re-routed to the remaining link. In the case of Segregation, the Ethernet traffic on the failed link will be “dropped”. The E1/T1 channels mapped across the East RF link will take priority during a link outage of either the East or West RF links. The E1/T1 channels mapped across the West RF link will be “dropped” during the link outage, and the Ethernet throughput will be reduced to what is available on the East RF link. QoS can be used to ensure high priority Ethernet traffic is transmitted on the remaining available Ethernet throughput.

To maximize protection of E1/T1 channels, map as many E1/T1 channels as possible to the East modem.

The 2+0 XPIC operational mode requires both links to remain active for proper operation. If a transmitter on an ODU fails, the other link will continue to operate, but the overall throughput will be reduced by one-half. However, if a receiver on an ODU fails, the reference signal required to cancel XPI will not be available and the remaining link will unlock if the XPI is too high. There is no XPIC fallback protection, so the link will fail.

Page 493: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Managing user accounts and security

phn-2779_001v000 (Jul 2012) 7-27

Managing user accounts and security

This section describes how to manage user accounts in operational PTP 810 links. It also describes how to configure the unit to operate in HTTPS (SSL) secure mode.

Creating user accounts

The MMU supports one administrator account and up to six user accounts. Multiple users may access the MMU with three defined levels of access: Administrator (administrator), Operator (Level 2) and Monitor (Level 1). Creating or updating user accounts may only be performed by a user with access level of Administrator.

To create a new user account, select menu option Administration, Maintenance, Add User. The Add User page is displayed (Figure 152). Enter the user’s attributes (Table 257) and select Add to create the new user account.

Figure 152 Add User page

Table 257 Add User attributes

Attribute Meaning

User Name The user’s name (maximum 15 characters).

User Name must start with an alphanumeric character and be followed by letters, numbers or other characters from the POSIX portable character class.

Group The user’s access level (Level 1 or Level 2).

Page 494: Cambium network ptp 810 series 01 00 user guide

Managing user accounts and security Chapter 7: Operation

7-28 phn-2779_001v000 (Jul 2012)

Attribute Meaning

Password The user’s password (maximum 15 characters).

Password must start with an alphanumeric character and be followed by letters, numbers or other characters from the POSIX portable character class.

Confirm Password Repetition of the user’s password.

Deleting user accounts

To delete a user account, select menu option Administration, Maintenance, Delete User. The Delete User page is displayed (Figure 153). In the ‘Delete User’ section of the page, choose User Name from the drop-down list and select Delete.

Figure 153 Delete User page

Page 495: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Managing user accounts and security

phn-2779_001v000 (Jul 2012) 7-29

Changing a password

To change a user’s password, select menu option Administration, Maintenance, Delete User. The Delete User page is displayed (Figure 153). In the ‘Change Password’ section of the page, choose User Name from the drop-down list, enter New Password and Confirm Password (Table 257), and select Change.

A user may change the password of any user whose access level is less than or equal to his own.

Viewing event log of MMU access

The event log shows the history of terminal access to the MMU in the form of a table listing users and their time of login. This log is non-volatile and available across MMU reboots.

To view the event log and clear it when required, select menu option Administration, Maintenance, View Event Log. The Event Log page is displayed (Figure 154). To clear the log, select Clear.

Figure 154 Event Log page

Page 496: Cambium network ptp 810 series 01 00 user guide

Managing user accounts and security Chapter 7: Operation

7-30 phn-2779_001v000 (Jul 2012)

Configuring HTTP (SSL)

Perform this procedure if the unit is required to operate in HTTP(SSL) mode.

To configure HTTPS (SSL), select menu option Administration, Security Configuration. The Security Configuration page is displayed (Figure 155). Update the attributes (Table 258) and select Update.

To revert to previous values, select Reset.

Figure 155 Security Configuration page

Table 258 Security Configuration attributes

Attribute Meaning

HTTP Access The type of HTTP Access (HTTP / HTTP(SSL) / Disabled).

‘HTTP(SSL)’ refers to the S-HTTP protocol, which uses SSL. There is a default certificate within the MMU for data encryption purposes.

Command Line Interface

The type of CLI Access (CLI over Telnet / CLI over SSH / Disabled).

Page 497: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Managing performance

phn-2779_001v000 (Jul 2012) 7-31

Managing performance

This section describes how to view and manage PTP 810 system statistics and diagnostics. To assist in managing PTP 810 performance, the GUI provides a number of graphs of the wireless link performance and tables of the Ethernet switch statistics.

Viewing wireless link performance

To review the graphs of the wireless link performance of a PTP 810 link, select menu option Analysis, Graphs. Based on the ODU Operational Mode configuration, the number of graphs displayed will differ.

Select any one link (that is, East or West) to view the graph of that parameter. The X-axis time range can be selected to be either 1, 2, 4, 12 or 24 hours. If 1 hour is selected, it will plot the graph using the last hour of data. The resolution of the data plotted is one value per 90 seconds.

When the mouse is moved over the graph area, the corresponding value at the mouse point will be displayed under the graph area. This enables the user to easily read X and Y values.

Page 498: Cambium network ptp 810 series 01 00 user guide

Managing performance Chapter 7: Operation

7-32 phn-2779_001v000 (Jul 2012)

RSL Graph

This screen graphs the East modem RSL, West modem RSL, or both for the time period selected (Figure 156).

Figure 156 RSL Graph

Page 499: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Managing performance

phn-2779_001v000 (Jul 2012) 7-33

Signal/Noise Ratio Graph

This screen graphs the East modem SNR, West modem SNR, or both for the time period selected (Figure 157). The SNR measurement is capped at a maximum of 25.5 dB.

When XPIC is enabled, the SNR is the resultant SNR after cross polar interference cancellation.

Figure 157 Signal Noise Ratio Graph

When XPIC is enabled, the SNR graph includes a plot of Signal/XPI (Figure 158). Signal/XPI measures the ratio of the wanted receive signal level to the cross polar interfering signal level in dB. This is prior to the effect of cross polar interference cancellation. Like SNR, the value is capped at 25.5 dB.

Page 500: Cambium network ptp 810 series 01 00 user guide

Managing performance Chapter 7: Operation

7-34 phn-2779_001v000 (Jul 2012)

Figure 158 XPIC SNR Graph

Page 501: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Managing performance

phn-2779_001v000 (Jul 2012) 7-35

Tx Power Graph

This screen graphs the East modem Tx Power, West modem Tx Power, or both for the time period selected (Figure 159).

Figure 159 Tx Power Graph

Page 502: Cambium network ptp 810 series 01 00 user guide

Managing performance Chapter 7: Operation

7-36 phn-2779_001v000 (Jul 2012)

RF Link Performance Graph

This screen graphs the East modem RF Link Performance or the West modem RF Link Performance for the time period selected. A variety of error second statistics are displayed (Figure 160).

Figure 160 RF Link Performance Graph

The statistics displayed are as follows:

• ES (Errored Seconds): A second in which at least one errored block is measured.

• SES (Severely Errored Seconds): A second in which more than 30% of Errored Blocks are measured.

• BBE (Background Block Errors): The number of Errored Blocks measured during a time period without SES.

• UAS (Unavailable Seconds): The period during which the link is out of service. It is detected counting the number of consecutive SES. The Unavailability is declared when 10 consecutive SES are detected on the radio link and removed when 10 consecutive non-SES are detected.

Page 503: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Managing performance

phn-2779_001v000 (Jul 2012) 7-37

• ESR (Errored Seconds Ratio): The ratio of Errored Seconds to available seconds.

• SESR (Severely Errored Seconds Ratio): The ratio of Severely Errored Seconds to available seconds.

• BBER (Background Block Errors Ratio): The ratio of Background Block Errors to blocks in available seconds.

• SUSPECT (Suspect Interval): A 15 minute interval in which the data is suspect due to one of the following user actions:

o Date and Time change

o SNTP parameter change

o System power up

o Link Reconfiguration

o Modem module extraction, insertion or not present

o Master IO module insertion

• TIME_ELAPSED (Elapsed Time): The amount of time that has elapsed in the current 15 minute interval. This value is more relevant to SNMP retrieval of current interval data than the value displayed in the graph.

Equalizer Taps Graph

This screen graphs the East modem Equalizer Taps or West modem Equalizer Taps (Figure 161). When XPIC mode is enabled, the Equalizer Taps graph includes XPIC plot data in the graph (Figure 162).

Figure 161 Equalizer Taps Graph

Page 504: Cambium network ptp 810 series 01 00 user guide

Managing performance Chapter 7: Operation

7-38 phn-2779_001v000 (Jul 2012)

Figure 162 XPIC Equalizer Taps Graph

Page 505: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Managing performance

phn-2779_001v000 (Jul 2012) 7-39

Constellation Graph

This screen graphs the East modem Constellation or West modem Constellation (Figure 163). When XPIC mode is enabled, the East or West Constellation graph includes Pre-XPIC constellation plot data in the provided graph (Figure 164).

Figure 163 Constellation Graph (256 QAM)

Page 506: Cambium network ptp 810 series 01 00 user guide

Managing performance Chapter 7: Operation

7-40 phn-2779_001v000 (Jul 2012)

Figure 164 XPIC Constellation Graph (256 QAM)

Page 507: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Managing performance

phn-2779_001v000 (Jul 2012) 7-41

Temperature Graph

This screen graphs the temperature of the MMU (shown as SDIDU), East ODU and West ODU over the time period selected. It also displays the current temperature of the MMU, East ODU and West ODU (Figure 165).

Figure 165 Temperature Graph

Page 508: Cambium network ptp 810 series 01 00 user guide

Managing performance Chapter 7: Operation

7-42 phn-2779_001v000 (Jul 2012)

Viewing Ethernet switch statistics

The MMU provides Ethernet switch statistics and STP status information for both NMS and payload. These statistics and status information are displayed in tables described in more detail below.

NMS switch statistics

To review the NMS switch statistics, select menu option Analysis, Statistics, NMS Switch. The NMS Switch Statistics screen is displayed (Figure 166). Press the ‘Clear’ button to clear the data and start accumulating again.

Figure 166 NMS Switch Statistics page

Page 509: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Managing performance

phn-2779_001v000 (Jul 2012) 7-43

The MMU provides the following Ethernet statistics for the Front-Panel NMS Ports as well as the radio link. The NMS Switch Statistics page (Figure 166) provides statistics and Tx/Rx Frames and Bytes per port in the switch.

• Each Port column lists the statistics related to the specified Front-Panel Port of the Master IO.

• The CPU column displays the statistics for the CPU port. This port will send and receive "management" packets for the Spanning-Tree Protocol. All packets transmitted and received on the CPU port will be reported, including HTTP, SNMP, and Telnet traffic.

• The Radio Link(s) column (East, West, or East & West) displays the statistics for the Radio Link port(s). The radio link refers to the RF link connected to the switch port. All packets sent and received over the radio link will be displayed in this column.

This page provides the attributes described in Table 259.

Table 259 NMS Switch Statistics attributes

Attribute Meaning

Spanning Tree Status Current Spanning Tree Port state:

Offline - Ethernet cable is disconnected.

Blocking - Port does not forward frames. Port will forward BPDU.

Learning - Port does not forward frames. Port will learn source address from frames received.

Forwarding - Port will forward frames.

Rx Bytes Cumulative bytes received into the MMU from the front panel or the radio link.

Rx Bytes/sec Bytes per second received into the MMU.

TX Bytes Cumulative bytes transmitted by the MMU out the front panel or the radio link.

TX Bytes/sec Bytes per second transmitted by the MMU.

Rx Frames Cumulative frames received into the MMU.

Rx Frames/sec Frames received per second into the MMU.

TX Frames Cumulative frames transmitted by the MMU.

TX Frames/sec Frames transmitted per second by the MMU.

Errors Cumulative number of packets received in error by the MMU. These packets are discarded.

Errors/sec Number of packets received in error per second.

Page 510: Cambium network ptp 810 series 01 00 user guide

Managing performance Chapter 7: Operation

7-44 phn-2779_001v000 (Jul 2012)

Attribute Meaning

Collisions Cumulative number of collisions on the Ethernet interface. Only valid when at least one interface is configured for half-duplex.

Collisions/sec Number of collisions per second on the Ethernet interface. Only valid when at least one interface is configured for half-duplex.

Payload switch statistics

To review the Payload switch statistics, select menu option Analysis, Statistics, Data Switch. The Data Switch Statistics page is displayed (Figure 167). Press the ‘Clear’ button to clear the data and start accumulating again.

Figure 167 Data Switch (payload port) Statistics page

Page 511: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Managing performance

phn-2779_001v000 (Jul 2012) 7-45

The MMU provides the following Ethernet statistics for the Front-Panel Payload Ports as well as the radio link. The data switch statistics screen provides statistics and Tx/Rx Frames and Bytes per port in the switch.

• Each Port column lists the statistics related to the specified Front-Panel Port of the Master IO.

• The CPU column displays the statistics for the CPU port. This port will send and receive "management" packets for the Spanning-Tree Protocol.

• The Radio Link(s) column (East, West, or East & West) displays the statistics for the Radio Link port(s). The radio link refers to the RF link connected to the switch port. All packets sent and received over the radio link will be displayed in this column.

This page provides the attributes described in Table 260.

Table 260 Data Switch (payload port) attributes

Attribute Meaning

STP Status Displays the Spanning-Tree Protocol status.

Rx Bytes Cumulative bytes received into the MMU from the front panel or the radio link.

Rx Bytes/sec Bytes per second received into the MMU.

TX Bytes Cumulative bytes transmitted by the MMU out the front panel or the radio link.

TX Bytes/sec Bytes per second transmitted by the MMU.

Rx Frames Cumulative frames received into the MMU.

Rx Frames/sec Frames received per second into the MMU.

TX Frames Cumulative frames transmitted by the MMU.

TX Frames/sec Frames transmitted per second by the MMU.

Errors Cumulative number of packets received in error by the MMU. These packets are discarded.

Errors/sec Number of packets received in error per second.

Collisions Cumulative number of collisions on the Ethernet interface. Only valid when at least one interface is configured for half-duplex.

Collisions/sec Number of collisions per second on the Ethernet interface. Only valid when at least one interface is configured for half-duplex.

Page 512: Cambium network ptp 810 series 01 00 user guide

Managing performance Chapter 7: Operation

7-46 phn-2779_001v000 (Jul 2012)

Ethernet NMS STP status

To review the system NMS STP status information, select menu option Analysis, Ethernet Switch, NMS STP Status. The Ethernet NMS status screen is displayed (Figure 168).

Figure 168 Ethernet NMS – IEEE 802.1w RSTP Status page

The Ethernet NMS Configuration allows for Spanning Tree Mode to be set as IEEE 802.1w (RSTP). When the Spanning Tree Mode selected is IEEE 802.1w RSTP, the NMS STP Status screen is active and provides system NMS status information for the IEEE 802.1w RSTP standard. The MMU provides the following Ethernet status for IEEE 802.1w RSTP and Front-Panel NMS Ports as well as the radio link.

Table 261 Ethernet NMS – IEEE 802.1w RSTP Status attributes

Attribute Meaning

Bridge Identifier Unique bridge identifier (ID) containing a configurable priority number and MAC address.

Root Bridge Identifier The bridge identifier with the smallest (lowest) bridge ID.

Designated Bridge Identifier

The bridge identifier for the Tx bridge.

Root Path Cost Path cost from the Tx bridge to the root bridge for the spanning tree instance.

Page 513: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Managing performance

phn-2779_001v000 (Jul 2012) 7-47

Attribute Meaning

Root Port Root port for the spanning tree instance.

Each Port column list the status and role related to the specified Front-Panel NMS Port of the Master IO.

The Radio Link(s) column (east, west, or East & West) displays the status and role for the Radio Link port(s). The radio link refers to the RF link connected to the switch port.

Ethernet Payload xSTP status

The MMU Ethernet Payload Configuration allows for Spanning Tree Mode to be set as IEE 802.1w (RSTP) or IEEE 802.1s (MSTP). When either Spanning Tree Mode is selected the Payload xSTP Status screen is active and provides system payload status information for the selected IEEE 802.1 standard. To review the system Payload xSTP status information, select menu option Analysis, Ethernet Switch, Payload STP Status. The Ethernet Payload page is displayed, either for RSTP (Figure 169) or for MSTP (Figure 170).

Figure 169 Ethernet Payload – IEEE 802.1w RSTP page

Page 514: Cambium network ptp 810 series 01 00 user guide

Managing performance Chapter 7: Operation

7-48 phn-2779_001v000 (Jul 2012)

Figure 170 Ethernet Payload – IEEE 802.1s MSTP page

The MMU provides the Ethernet status attributes described in Table 262 for MSTP/RSTP and Front-Panel Payload Ports as well as the radio link.

Page 515: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Managing performance

phn-2779_001v000 (Jul 2012) 7-49

Table 262 Ethernet Payload attributes

Attribute Meaning

Configuration Name Variable length string encoded within a fixed field of 32 octets, conforming to RFC 2271's definition of SnmpAdminString.

Revision Revision level, an unsigned integer encoded within a fixed field of 2 octets.

Configuration Digest A 16-octet signature of type HMAC-MD5 created from the MST Configuration table.

Instance One of a number of Spanning Trees calculated by MSTP within an MST Region.

Instance Priority Priority of the Spanning Tree instance.

Included VLANs Allocation of defined VLAN to Spanning Trees.

Bridge Identifier Unique bridge identifier (ID) containing a configurable priority number and MAC address.

Root Bridge Identifier The bridge identifier with the smallest (lowest) bridge ID.

Designated Bridge Identifier

The bridge identifier for the Tx bridge.

Root Path Cost Path cost from the Tx bridge to the root bridge for the spanning tree instance.

Root Port Root port for the spanning tree instance.

CST Regional Root Common spanning tree bridge identifier (ID) as the single bridge in a Region whose CIST Root Port is a Boundary Port or the Bridge Identifier of the CIST Root if that is within the Region.

CST Internal Root Path Cost

Common spanning tree path cost to the CIST Regional Root.

Each Port column list the status and role related to the specified Front-Panel NMS Port of the Master IO.

The Radio Link(s) column (east, west, or East & West) displays the status and role for the Radio Link port(s). The radio link refers to the RF link connected to the switch port.

Page 516: Cambium network ptp 810 series 01 00 user guide

Managing performance Chapter 7: Operation

7-50 phn-2779_001v000 (Jul 2012)

Maintaining the system

Once installed, a PTP 810 link should require little or no maintenance.

Yearly maintenance

Recommended yearly physical maintenance:

• Check cables for corrosion, chafing etc.

• Check waterproofing.

• Check ground points for corrosion, tightness etc.

• 1+1 Hot Standby link maintenance

For a 1+1 Hot Standby link, consider a controlled switchover to the inactive unit (once every three months), to confirm that it is fully functional.

This can cause a short interruption to traffic and should be scheduled accordingly to minimize the effects.

Page 517: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Saving, restoring and rebooting

phn-2779_001v000 (Jul 2012) 7-51

Saving, restoring and rebooting

This section describes how to save and restore the system configuration, and how to reboot the unit.

This section contains the following procedures:

• Saving the system configuration on page 7-51

• Restoring the system configuration on page 7-52

• Rebooting on page 7-53

• Checking the recovery version on page 7-53

Saving the system configuration

The PTP 810 MMU supports a limited ability to save system configuration information. The Store Configuration feature of the MMU is designed to store general non-volatile configuration parameters, VLAN configuration parameters and STM Trace message configuration parameters. It is intended primarily for use in replicating the same custom configuration across several MMUs with identical hardware and software versions. This feature is supported only from the Web GUI.

The process for restoring a PTP 810 MMU to a previously saved configuration is described in Restoring the system configuration on page 7-52.

To save the current configuration, select menu option Administration, Restore Configuration. The Store/Restore Configuration page is displayed (Figure 171). Select Download the Configuration to store the set of configurations. A dialogue box indicating “save” option is displayed with the file name ‘config_info.bin’. Save the configuration file to a PC hard drive which can be used for restoring configurations.

Figure 171 Save/Restore Configuration page

Page 518: Cambium network ptp 810 series 01 00 user guide

Saving, restoring and rebooting Chapter 7: Operation

7-52 phn-2779_001v000 (Jul 2012)

Restoring the system configuration

Perform this procedure to restore a PTP 810 MMU to a previously saved configuration. Refer to Saving the system configuration on page 7-51 for instructions on when and how to save the configuration.

Licensed capabilities

The authorization key is not restored automatically if the configuration file is saved and then loaded on the same unit. When restoring configuration to a PTP 810 unit, ensure that a valid authorization key is installed as well. For instructions, see Entering an authorization key on page 7-60.

Restoring from the configuration file

To restore the system configuration from file, select menu option Administration, Restore Configuration. The Store/Restore Configuration page is displayed (Figure 171). Select Browse and navigate to the PC folder containing the saved configuration file named “config_info.bin”. Select the Upload the Configuration tab. The configuration file is uploaded and used to reconfigure the new unit to the same state as the old unit. After uploading the configuration file, do an “IDU Reboot”, see Rebooting on page 7-53, or power cycle the MMU to restore the configuration.

Attributes excluded from store and restore

The following system configuration attributes that were part of the configuration are not stored or restored automatically. These configuration attributes will retain their previous configuration values following a Restore Configuration operation.

• General Network Configuration:

o IP Address

o IP Netmask

o IP Gateway

• Device Information:

o Serial numbers

o Device Names:

Device Name

Host Name

Model Number

Owner

Page 519: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Saving, restoring and rebooting

phn-2779_001v000 (Jul 2012) 7-53

Contact

Description

Location

• Reprogramming Information:

o Version numbers and bank information

o Software components

• Authorization key.

Rebooting

To reboot the MMU, select menu option Administration, Reboot. The System Reboot page is displayed (Figure 172). This screen enables the operator to reboot the MMU or certain devices within the MMU. It will display a list of devices and the operator can select depending on the availability and configuration of devices. To reboot the MMU, select the IDU device. Click the Reboot button. The reboot progress message is displayed. On completion, the unit restarts.

Figure 172 System Reboot page

Checking the recovery version

To confirm the recovery software version, select menu option Administration, Maintenance, Reprogramming and note the Active software images highlighted in green.

Page 520: Cambium network ptp 810 series 01 00 user guide

Restoring system defaults Chapter 7: Operation

7-54 phn-2779_001v000 (Jul 2012)

Restoring system defaults

This section describes how to restore the MMU system defaults. There are two procedures that can be performed to restore the MMU parameters to their default values. One procedure requires the operator to press the CALL button of the Master I/O module during power up to restore system defaults. The other procedure uses the Restore System Defaults page from the GUI menu.

Power on reset to system defaults

The MMU may be reset to system defaults during power up. A power on reset restores the MMU parameters to their default values (see Table 263).

To perform a power on reset, proceed as follows:

1 Power on the MMU.

2 Toward the end of system bootup, the MMU will flash the controller card LED an alternating red and green pattern for a five second period.

3 Make sure the CALL button of the Master I/O module is not active at the start of this five second period.

4 While the LED is flashing the alternating red and green pattern, press the CALL button. Release the call button within one second after the LED stops flashing.

5 The MMU parameters will be restored to their system default values.

Restore system defaults page

The MMU may be reset to system defaults using the Restore System Defaults page from the GUI menu. Clicking the ‘Restore’ button on this page restores the MMU parameters to their default values (see Table 263).

To restore system defaults using the Restore System Defaults page, proceed as follows:

1 Navigate to Administration, Restore Defaults.

2 The Restore System Defaults page is displayed (Figure 173).

3 Click on the ‘Restore’ button.

4 The MMU parameters will be restored to their system default values.

Page 521: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Restoring system defaults

phn-2779_001v000 (Jul 2012) 7-55

Figure 173 Restore System Defaults page

System default parameter values

Table 263 lists the MMU parameters and their default values that are restored during a restore system defaults procedure.

Table 263 MMU system default parameters

MMU parameter Default value

IP Address 192.168.0.1

IP Netmask 255.255.255.0

IP Gateway 192.168.0.2

DHCP Enable Disable

SNTP Server Address 0.0.0.0

SNTP Server Enable Disable

Timezone 0

Date Format European

UPL STP status DISABLED

UPL Bridge Priority 32768

UPL Max Age 20

UPL Hello Time 2

UPL Forward Delay 15

Read Community public

Write Community private

Trap Community public

Trap Manager #1 0.0.0.0

Trap Manager #2 0.0.0.0

Page 522: Cambium network ptp 810 series 01 00 user guide

Restoring system defaults Chapter 7: Operation

7-56 phn-2779_001v000 (Jul 2012)

MMU parameter Default value

Trap Manager #3 0.0.0.0

Trap Manager #4 0.0.0.0

Auth Trap Enable Disable

Trap Version V1

SNMP Mode v1-v2-v3

Auth Password <blank field>

Priv Password <blank field>

SMTP Enable Disable

SMTP Server IP 0.0.0.0

SMTP Port 25

SMTP Username <blank field>

SMTP Password <blank field>

e-mail #1 <blank field>

e-mail #2 <blank field>

e-mail #3 <blank field>

HTTP Access Type HTTP

Command Line Interface

CLI over Telnet

Syslog Server 0.0.0.0

Syslog Facility Local 1

Data Baud rate 38400

Page 523: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Viewing device information

phn-2779_001v000 (Jul 2012) 7-57

Viewing device information

This section describes how to view MMU general device and serial number information, and how to modify MMU device name related information.

General device information

To view general device information, select menu option Administration, Device Information, General. The read-only terminal information is displayed on the Device Information page (Figure 174). Review the attributes (Table 264).

Figure 174 Device Information page

Table 264 Device Information attributes

Attribute Meaning

Model Number Model number of the terminal.

Chassis Serial Number Chassis serial number assigned during manufacturing.

Application Version Active application version information.

Date Current date.

Time Current time.

Page 524: Cambium network ptp 810 series 01 00 user guide

Viewing device information Chapter 7: Operation

7-58 phn-2779_001v000 (Jul 2012)

Serial number information

To review Part Number, Revision and Serial Number information for the various cards in the MMU, select menu option Administration, Device Information, Serial Numbers. This read-only information is displayed on the Serial Number Information page (Figure 175).

Figure 175 Serial Number Information page

The following cards numbers are displayed: Controller card, Master IO card, Expansion IO card (displayed only if Expansion card installed), Power Supply cards, Modem cards, IF cards, ODU, chassis, and SFP module (displayed only if SFP module installed).

The Part Number is a combination of four numbers for the module type and four numbers for the module revision xxxx-yyyy. The first four numbers xxxx can be used to determine the type of module installed such as the '4130-yyyy' for a GigE Master IO Module.

Device name and owner information

To modify MMU device name related information, select menu option Administration, Device Information, Device Names. The device name and owner related parameters are displayed with their current values on the Device Names page (Figure 176). Update the attributes (Table 265) and select Update.

The Device Name and Owner values are displayed at the top of each web interface page. These attributes can be used to give a personalized appearance to the web interface.

Page 525: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Viewing device information

phn-2779_001v000 (Jul 2012) 7-59

Figure 176 Device Names page

Table 265 Device Names attributes

Attribute Meaning

Device Name The name of the device.

Host Name The host name of the device. The host name should not contain any spaces.

Model Number MMU model number.

Owner The name of the device owner.

Contact The contact information of owner.

Description The device description.

Location The device location.

Page 526: Cambium network ptp 810 series 01 00 user guide

Upgrading the system Chapter 7: Operation

7-60 phn-2779_001v000 (Jul 2012)

Upgrading the system

This section describes how to enter an authorization key to increase data capacity or implement XPIC. It also describes how to install a new software version.

Entering an authorization key

Perform this task to increase the data throughput capacity of the MMU (it is shipped with capacity 10 Mbps) or to install XPIC capability.

Before performing this task, obtain the necessary authorization key(s), as described in Ordering capacity upgrades and XPIC capability on page 2-40. Only one authorization key can be entered and made active in the MMU at any time.

To enter an authorization key, select menu option Link Configuration, Authorization. The Authorization Key page is displayed (Figure 177). Update the attributes (Table 266) and select Update. To revert to previous values, select Reset.

If the entered authorization key is valid, “Key accepted” is displayed. Otherwise “Invalid Key” is displayed.

To authorize XPIC capability, enter an XPIC authorization key for the System Level as well as the East Modem and West Modem using the Slot Name parameter. When XPIC is enabled correctly with all three keys, the East and West Modem XPIC entries are displayed in the list of Authorized Features (Figure 178).

The MMU enables only those modulation modes in which:

Maximum throughput capacity of modulation mode (channel size and modulation) is less than or equal to authorization key capacity.

Page 527: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Upgrading the system

phn-2779_001v000 (Jul 2012) 7-61

Figure 177 Authorization Key

Table 266 Authorization Key attributes

Attribute Meaning

Slot Name The device for which the authorization key will apply (System Level / East Modem / West Modem). The default selection is System Level.

Auth Key The authorization key provided by PTP License Key Generator.

Embedded Payload Authorization

In the MMU the Authorization Key setting for Embedded Payload Configuration is always enabled and cannot be changed.

Page 528: Cambium network ptp 810 series 01 00 user guide

Upgrading the system Chapter 7: Operation

7-62 phn-2779_001v000 (Jul 2012)

Attribute Meaning

Authorized Features Displays the list of features that are enabled by a specific authorization key. Figure 177 displays the list of features enabled by a “1+x” Authorization Key.

Figure 178 XPIC Authorization Key

Page 529: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Upgrading the system

phn-2779_001v000 (Jul 2012) 7-63

Installing new software versions

This task consists of the following procedures:

• Checking the installed software version on page 7-63

• Installing a new software version on page 7-65

Ensure that the correct units are upgraded, as units cannot easily be downgraded afterwards.

If the link is operational, ensure that the remote end of the link is upgraded first using the wireless connection, and then the local end can be upgraded. Otherwise, the remote end may not be accessible.

Checking the installed software version

The MMU software consists of a number of software images associated with the various modules that are installed in the MMU. To check the installed software image versions, select menu option Administration, Maintenance, Reprogramming. The Reprogramming page is displayed (Figure 179). Two banks of MMU software versions are displayed for each software image. The Active software images are highlighted in green.

Page 530: Cambium network ptp 810 series 01 00 user guide

Upgrading the system Chapter 7: Operation

7-64 phn-2779_001v000 (Jul 2012)

Figure 179 Reprogramming page

The Reprogramming page is used to reprogram / upgrade the MMU software. This screen enables the user to upgrade the Kernel, Application, Controller FPGA, Master I/O FPGA, ODU, Boot Loader, ODU East/West firmware and Modem East/West firmware images. This screen also allows the user to upgrade the following:

• Modes: The Modes file is a customized list that defines the modes of the MMU.

• Channels: The Channels file is a customized channels file that is uploaded onto each MMU.

Go to the support web page (see Contacting Cambium Networks on page 2) and navigate to Point-to-Point Software and Documentation. Check that the latest software image versions are the same as the installed software image versions.

To upgrade to new image versions, perform Installing a new software version on page 7-65.

Page 531: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Upgrading the system

phn-2779_001v000 (Jul 2012) 7-65

Installing a new software version

MMU software versions must be the same at both ends of the link. Install the new software version at the remote end of a link before the local end. For a 1+1 Hot Standby link, if there are modem firmware or modem FPGA images that need new versions, install the new software versions in the inactive modems and force a protection switch to them before installing new versions in the active modems. This approach maximizes system availability.

To swap the Active and Passive firmware images for a given module, proceed as follows:

1 For each module that needs its software image to be swapped, select the square radio button located at the left side of the Image column.

2 To swap the Active and Passive software images for the selected modules, select Toggle.

To upload a new software image, proceed as follows:

1 Go to the support web page (see Contacting Cambium Networks on page 2) and navigate to Point-to-Point Software and Documentation. Download and save the required software image.

2 Use an FTP client and connect to the MMU via IP address.

3 Enter command “ftp <IP address of MMU>”.

4 Enter the administrator username and password when prompted.

5 Set the mode to binary by entering “bin”.

6 To upload the file, enter the command “put <filename>” and wait for the upload to complete.

7 Exit the FTP client.

8 Log into the MMU web interface and select menu option Administration, Maintenance, Reprogramming. The Reprogramming page is displayed (Figure 179).

9 For the software images being upgraded, click on the square radio button located at the left side of the Image column, then select Toggle.

10 When done, there should be a red dot next to each firmware image being upgraded.

11 Some firmware upgrades, such as the kernel, application, FPGA or ODU images, require that a reboot be performed before the upgrades are configured in the MMU. Select menu option Administration, Reboot and wait for the reboot to complete.

Page 532: Cambium network ptp 810 series 01 00 user guide

Upgrading the system Chapter 7: Operation

7-66 phn-2779_001v000 (Jul 2012)

12 Some firmware upgrades, such as the modes file, require that a new link configuration be performed before the upgrades are configured in the MMU. To achieve this:

a. Select menu option Link Configuration, Radio Link, Link Configuration.

b. Create a new link configuration.

c. In the Summary of Configuration page, select Update All and wait for the link configuration to complete.

13 When the reboot or link configuration is complete, there should be green dots next to each firmware image that was upgraded in the MMU.

To update the ODU East/West firmware images, proceed as follows:

1 Rename the ODU software image filename to “east_odu_fw.s19” if the ODU is connected to the “east” modem or “west_odu_fw.s19” if the ODU is connected to the west modem.

2 FTP one file at a time to the MMU. Administrator login credentials are required to perform this operation.

3 The ODU firmware will be installed in the inactive bank. Toggle the ODU firmware bank of the MMU.

4 Reboot the ODU for the uploaded ODU firmware to become active.

To enable XPIC, load the XPIC license authorization key and verify that the software image for the XPIC library is Active on both the Modem East FPGA and Modem West FPGA.

The spare Control Module is by default installed with the Standard Master I/O FPGA image. If a different Master I/O module (for example GigE Master I/O) is installed in an MMU where a spare Control Module needs to be installed, then reload the appropriate firmware image for the existing Master I/O module, toggle the “Master IO FPGA” bank and perform a Reboot of the MMU.

Page 533: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Removing and installing modules

phn-2779_001v000 (Jul 2012) 7-67

Removing and installing modules

This section describes the procedure to be performed to install or remove the various modules in the MMU.

There may be up to eight modules installed in a single MMU chassis. Figure 180 shows the front panel of the MMU with each module labelled. The PTP 810 01-00 release does not support the Mini I/O module.

Figure 180 MMU Modules

All the modules of the MMU are inserted from the front panel of the MMU chassis. All of the modules are hot swappable. Any module plugged into the MMU may be replaced without powering down the MMU.

Preparing to remove and install a module

To avoid damaging MMU modules, take the following precautions before performing any procedure on the MMU:

Modules are static sensitive and should only be handled in an ESD-safe environment. Always place the cards on a clean, anti-Static surface. When packaging modules for shipment or storage, place in an ESD bag.

When removing a module, remove existing front panel connections to the module.

Page 534: Cambium network ptp 810 series 01 00 user guide

Removing and installing modules Chapter 7: Operation

7-68 phn-2779_001v000 (Jul 2012)

Removing a module

No loss of user data occurs during a replacement of the Control Module, but the IP addresses will need to be reprogrammed.

Replacing a standby Modem module or Power Supply module used in a 1+1 protection configuration will not cause user traffic disruption or loss of lock.

Replacing a Master I/O module or an Expansion I/O module will result in user traffic disruption.

To remove a module, remove the two thumbscrews on either side of the module. Figure 181 shows the locations of the thumbscrews.

Figure 181 Thumbscrew Locations

Thread thumbscrew(s) into hole(s) shown in Figure 182. Remove the module by grasping the thumbscrew(s) and pulling the module straight out of the MMU. Both thumbscrews should be used for all modules except the Power Supply which only has one threaded hole.

Figure 182 Threaded Hole Locations

Page 535: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Removing and installing modules

phn-2779_001v000 (Jul 2012) 7-69

Installing a module

To install a module, proceed as follows:

1 Line up the module board with the guides in the chassis and slide the module into the MMU. Figure 183 shows a photo of the guides. As the module face plate comes flush with the face of the MMU, connectors on the back of the module will engage with the MMU backplane. It is possible to encounter interference from adjacent module front panels. If this occurs, loosen the thumbscrews holding the neighboring panels and shift them as necessary to ensure fit.

2 Install thumbscrews on either side of the module as shown in Figure 181.

3 Make front panel connections to the module.

4 Verify proper operation of the unit.

5 If the Control Module has been changed, reprogram the IP addresses (see Task 2: Configuring IP and Ethernet interfaces on page 6-14).

Figure 183 Guides

Installing dual modem upgrade kit

The dual modem upgrade kit consists of a second Modem module and Power Supply module that need to be installed into an existing single modem MMU. An operating MMU will not need to be powered down or cause user traffic disruption while installing these two modules.

To install the dual modem upgrade kit, proceed as follows:

Guide

Page 536: Cambium network ptp 810 series 01 00 user guide

Removing and installing modules Chapter 7: Operation

7-70 phn-2779_001v000 (Jul 2012)

1 Remove the thumbscrews on either side of the faceplates that cover the location for the second Power Supply module and Modem module.

2 Remove the faceplates that cover the location for the second Power Supply module and Modem module.

3 Install the second Power Supply module and Modem module using the Installing a module procedure on page 7-69.

4 Supply power to the new Power Supply module.

5 Install the additional antenna, ODU and IF cable planned for use with the second modem using the procedures from Chapter 5: Installation.

6 Connect the IF cable to the new Modem module.

7 Depending on the planned configuration of the MMU, a license key upgrade may need to be purchased and/or a new Authorization Key may need to be entered using the procedures from Entering an authorization key on page 7-60.

8 Review the MMU Reprogramming screen (see Figure 179) to ensure the correct Modem and ODU software images are in place using the Installing new software versions procedures on page 7-63. Toggle or upload software images as needed.

9 Reconfigure the MMU wireless interface to the desired operational mode using the Task 3: Configuring wireless interface on page 6-24.

Software images stored on MMU modules

The software images that are displayed on the MMU Reprogramming screen (see Figure 179) are not all stored on the same module in the MMU. This has a direct impact on which software images may need to be toggled or reloaded depending on which module cards are replaced or installed. Specific toggling/reloading requirements are dependent on specific replacement/installation scenarios. It is important to review the Reprogramming screen to ensure that the expected software components are in place after any hardware modification is completed.

Table 267 lists the MMU software images along with the modules where these images are stored.

Table 267 MMU software images and module storage

MMU software image Module where software image is stored

Kernel Control Module

Application Control Module

Controller FPGA Control Module

Master IO FPGA Control Module

Page 537: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Removing and installing modules

phn-2779_001v000 (Jul 2012) 7-71

MMU software image Module where software image is stored

ODU Control Module

Modes Control Module

Channels Control Module

ODU East Firmware ODU (ODU firmware version is displayed by the MMU)

ODU West Firmware ODU (ODU firmware version is displayed by the MMU)

Bootloader Control Module

Modem East Firmware Modem Module

Modem East FPGA Modem Module

Modem West Firmware Modem Module

Modem West FPGA Modem Module

Expansion IO FPGA Expansion IO Module

Page 538: Cambium network ptp 810 series 01 00 user guide

Removing and installing modules Chapter 7: Operation

7-72 phn-2779_001v000 (Jul 2012)

Page 539: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide

phn-2779_001v000 (Jul 2012) 8-1

Chapter 8: Troubleshooting

This chapter describes how to identify and correct faults in a PTP 810 link.

The following topics are described in this chapter:

• Trouble connecting to the web management interface on page 8-2: perform this task if any problems are encountered when connecting to the PTP 810 web interface.

• Trouble establishing a wireless link on page 8-8: perform this task if any problems are experienced with a newly installed (or operational) wireless link.

• Trouble bridging Ethernet data traffic on page 8-12: perform this task if any problems are encountered when attempting to send Ethernet data traffic over an established wireless link.

• Trouble bridging E1/T1 traffic on page 8-15: perform this task if any problems are experienced with E1/T1 channels in a newly installed (or operational) link.

• Trouble managing remote unit on page 8-20: perform this task if any problems are encountered when trying to manage the remote unit.

Page 540: Cambium network ptp 810 series 01 00 user guide

Trouble connecting to the web management interface Chapter 8: Troubleshooting

8-2 phn-2779_001v000 (Jul 2012)

Trouble connecting to the web management interface

Perform this task if any problems are encountered when connecting to the PTP 810 web interface.

Check the MMU power supply status LED

The MMU power supply status LED shows the presence of the DC supply within the MMU.

Check the state of the MMU power supply status LED and take action as described in Table 268.

Table 268 MMU power supply status LED checks

MMU power supply status LED state

Likely cause and action

Green steady Continue at Check the MMU status indicator on page 8-3.

Off The DC supply may be absent or the MMU may be faulty. Continue at Check the DC supply to the MMU on page 8-2.

Red When both power supply modules are installed, the LED will turn to red on the faulty supply. The DC supply may be absent or the MMU may be faulty. Continue at Check the DC supply to the MMU on page 8-2.

Check the DC supply to the MMU

Check the DC supply at the MMU using a suitable voltmeter and take action as described in Table 269.

Table 269 DC supply checks when MMU power supply status LED is off or red

DC supply state Likely cause and action

Absent or less than –41 V Check the AC supply, power converters, wiring, circuit breakers and fuses as appropriate.

Reversed polarity The MMU power supply module could be damaged. Correct the polarity, then replace the MMU Power Supply module.

Page 541: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Trouble connecting to the web management interface

phn-2779_001v000 (Jul 2012) 8-3

DC supply state Likely cause and action

Correct polarity and within the range –41 V to –60 V.

The MMU has an internal power supply fault. Replace the MMU Power Supply module.

Check the MMU status indicators

The MMU status indicators show if the MMU has a hardware fault or is operating in normal mode. Additionally, in normal mode it indicates if the wireless link is locked or unlocked.

Check the state of the MMU status indicator and take action as described in Table 270.

Table 270 MMU status indicator checks

MMU status indicator state Likely cause and action

Controller card status LED is Orange steady or flashing an alarm code in Orange.

The controller card is operating in normal mode. Continue at Check the NMS port Ethernet connection on page 8-3.

Controller card status LED is flashing an alarm code in Red.

This is an indication of a controller card fault, which may impair ability to connect to the web management interface. Replace the controller card.

Check the NMS port Ethernet connection

Check the state of the NMS port indicators and take action as described in Table 271.

Table 271 NMS port indicator checks

NMS port indicator state Likely cause and action

Green steady The Ethernet link is locked. Continue at Check IP network connection on page 8-4.

Off The Ethernet link is unlocked. Continue at NMS port indicator is off on page 8-4.

Page 542: Cambium network ptp 810 series 01 00 user guide

Trouble connecting to the web management interface Chapter 8: Troubleshooting

8-4 phn-2779_001v000 (Jul 2012)

NMS port indicator is off

If the NMS port indicator is off, it means that the Ethernet link is unlocked.

If the NMS port is connected to a management network, check the following:

• The associated network equipment (workstation, PC, router, switch etc.) is powered up and operating correctly.

• The Ethernet port in the associated equipment is enabled.

• The Ethernet cable between the MMU and the network equipment is connected and is not damaged. If possible, substitute a known good Ethernet cable.

If the NMS port is connected directly to a PC, check the following:

• The Ethernet port in the PC is enabled.

• The Ethernet cable between the MMU and the PC is connected and is not damaged. If possible, substitute a known good Ethernet cable.

If these steps fail to resolve the problem, continue at Restoring system defaults on page 7-54.

Check IP network connection

If the NMS port indicators are illuminated but the IP address of the MMU is unknown, use a hyperterminal connection via a serial cable to set the IP address (see Using a serial port connection to set the IP address on page 8-5).

If the IP address of the MMU is known, send a sequence of ICMP Echo Request packets to the MMU management agent using the Ping program at the command line interface of the management PC or workstation.

If the MMU responds then the command line will appear similar to this:

C:\ping 169.254.1.1 Pinging 169.254.1.1 with 32 bytes of data: Reply from 169.254.1.1: bytes=32 time=1ms TTL=64 Reply from 169.254.1.1: bytes=32 time<1ms TTL=64 Reply from 169.254.1.1: bytes=32 time<1ms TTL=64 Reply from 169.254.1.1: bytes=32 time<1ms TTL=64 Ping statistics for 169.254.1.1: Packets: Sent = 4, Received = 4, Lost = 0 (0% loss), Approximate round trip times in milli-seconds: Minimum = 0ms, Maximum = 1 ms, Average = 0ms

Page 543: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Trouble connecting to the web management interface

phn-2779_001v000 (Jul 2012) 8-5

If the MMU fails to respond then the command line will appear similar to this: C:\ping 169.254.1.1 Pinging 169.254.1.1 with 32 bytes of data: Request timed out. Request timed out. Request timed out. Request timed out. Ping statistics for 169.254.1.1: Packets: Sent = 4, Received = 0, Lost = 4 (100% loss),

Check the Ping response and take action as described in Table 272.

Table 272 Ping response checks

Ping response Likely cause and action

Reply The IP network is providing connectivity between the PC and MMU. Continue at Check browser settings on page 8-5.

Request timed out There is no IP connectivity. Check network configuration including IP addresses, gateway address, subnet masks, VLAN membership in network equipment between the PC and the MMU. Check if the PC can reach other equipment in the same network.

If these steps fail to resolve the problem, continue at Power on reset to system defaults on page 7-54.

Check browser settings

If there is IP connectivity between the MMU and the management PC or workstation, but web-pages cannot be displayed, check that browser settings are appropriate for the PTP 810 web interface (see Logging into the web interface on page 6-7).

Using a serial port connection to set the IP address

To set the IP address using a serial port connector, proceed as follows:

1 Connect the Serial/Alarm port on the MMU (Table 85) to a COM port on the computer.

Page 544: Cambium network ptp 810 series 01 00 user guide

Trouble connecting to the web management interface Chapter 8: Troubleshooting

8-6 phn-2779_001v000 (Jul 2012)

2 Start a hyperterminal session and select the following COM port settings:

Bits per second: 38400 Data bit: 8 Parity: None Stop bits: 1 Flow control: None

3 The following terminal and ASCII settings are recommended for best viewing:

Emulation: VT100 Line delay: 50 ms Character delay: 10 ms Text wrap: On

4 Connect to the MMU. Once the connections complete, power on the MMU.

5 Once the boot process is complete, press the keyboard return key to receive a login prompt. Log in with the username and password.

6 Press the M-key to navigate to the Main Menu.

7 Press the B-key to navigate to Administration.

8 Press the A-key to navigate to Network Configuration.

9 Press the A-key to navigate to General.

10 Press the A-key to navigate to IP Address.

11 Enter the new IP address and press the D-Key to update. If the IP address has been entered correctly enter Y when prompted.

12 If necessary, use the same menus to set the IP Netmask and IP Gateway.

13 Close the hyperterminal connection.

Unable to access MMU using HTTPS

Verify that the IP address of the MMU can be pinged.

Verify that the HTTP Access in the Security Configuration page is set to ‘HTTP (SSL)’ (see Configuring HTTP (SSL) on page 7-30).

Verify that ‘Use SSL 2.0’ and ‘Use SSL 3.0’ options are selected in the Security options of the browser.

Re-attempt to login to the Web interface using HTTPS.

Page 545: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Trouble connecting to the web management interface

phn-2779_001v000 (Jul 2012) 8-7

Unable to access MMU using Telnet

Verify that the IP address of the MMU can be pinged.

Verify that Telnet is enabled (see Configuring HTTP (SSL) on page 7-30).

Re-attempt to access the MMU using the procedure given in Logging into the CLI interface on page 6-9.

Unable to access MMU using SSH

Verify that the IP address of the MMU can be pinged.

Verify that SSH is enabled (see Configuring HTTP (SSL) on page 7-30).

Re-attempt to access the MMU using the procedure given in Logging into the CLI interface on page 6-9.

Unable to access MMU using serial port

Verify that the serial cable between the MMU and the PC is properly connected and is not damaged (Table 85). If possible, substitute a known good serial cable.

Verify that the serial port is properly configured (see Configuring Serial Port on page 6-15).

Re-attempt to access the MMU using the procedure given in Logging into the CLI interface on page 6-9.

Page 546: Cambium network ptp 810 series 01 00 user guide

Trouble establishing a wireless link Chapter 8: Troubleshooting

8-8 phn-2779_001v000 (Jul 2012)

Trouble establishing a wireless link

Perform this task if any problems are experienced with a newly installed (or operational) wireless link.

Connect to the web management interface

See Trouble connecting to the web management interface on page 8-2.

Check for proper link configuration and connectivity

If the MMU is not properly configured on both ends of a link or if the MMU is not properly connected to the ODU, there will be problems in installing a wireless link.

If a problem occurs in installing a wireless link, check the link configuration problem list and take action as described in Table 273. For other problems, continue at Transmitter status on page 8-10.

Table 273 Link configuration problems

Link configuration problem Likely cause and action

Invalid ODU frequency:

When configuring the link, the ODU Channel Selection (see ODU Channel Selection on page 6-30) shows “0 GHz” frequency range.

This means that the MMU is not able to detect the ODU. Make sure that the ODU is connected correctly with the MMU. If problems persist, report a suspected ODU fault to Cambium.

Invalid ODU Start Tx Power:

When configuring the link, the ODU “Start Tx Power” pulldown menu (see ODU Tx Power Configuration on page 6-29) shows “0.0” only.

This means that the MMU is not able to detect the ODU. Make sure that the ODU is not impaired and make sure that the ODU and MMU are connected.

Page 547: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Trouble establishing a wireless link

phn-2779_001v000 (Jul 2012) 8-9

Link configuration problem Likely cause and action

Unable to get link locked:

When configuring the link, the Status Panel shows an RSL level of “Green”, but the link won’t lock.

Check the “Configuration Summary” page (see Figure 99):

Make sure that the configuration of both end matches with each other. For example, the modulation rate and channel size must be matched (both end use the same IDU operational mode), frequency configuration of both end matches with each other and the number of TDM channels configured on both ends are the same.

Check the “Reprogramming” page (see Figure 179):

Make sure that the MODES file being used (Active Image) on both ends of the link are correct and identical.

Continue at Transmitter status on page 8-10.

Link is locked on only one end:

One end of the link shows that it is locked, while the other end shows that it is unlocked.

View the “Status Panel” on the right hand side of the Web interface (see Viewing the system status on page 7-4). Check the Tx power on the “locked” end and verify that the ODU is transmitting at the expected Tx power.

Continue at Transmitter status on page 8-10.

Link is locked, but unable to access remote MMU’s management page

Check that RSTP is enabled on the NMS network (see Configuring Ethernet network management on page 6-21) of both ends of the link to avoid any Ethernet loop.

Make sure that all “Loopback” tests are disabled by checking the “Loopback” configuration page.

Page 548: Cambium network ptp 810 series 01 00 user guide

Trouble establishing a wireless link Chapter 8: Troubleshooting

8-10 phn-2779_001v000 (Jul 2012)

Link configuration problem Likely cause and action

Link is locked, but user IP traffic is not bridged

Check that the VLAN tagging configuration is correct if VLAN is used (see Task 11: Configuring VLAN on page 6-73).

In any ring configuration (East/West), verify that spanning tree is enabled for the payload network (see Configuring Ethernet payload on page 6-16).

In an 2+0 or 2+0 XPIC configuration, avoid loops by enabling “trunk mode”, spanning tree, or by properly configuring port forwarding (see Configuring port based VLANs on page 6-77).

Transmitter status

Ensure that the transmitter is enabled. The status of the transmitter is indicated by the Transmitter attribute (ACTIVE, STANDBY, OFF or ON) in the Status Panel of the web interface (Figure 146 and Figure 147).

The transmitter is enabled during installation (see Task 3: Configuring wireless interface on page 6-24). The transmitter may additionally be enabled, disabled, muted or unmuted using the web interface (see Disabling, enabling, muting and unmuting the ODU on page 7-21).

In the Status Panel the transmitter needs to be ‘Active’ and the modem ‘locked’ for proper operation of an active link. If the transmitter is ‘Active’, but the modem remains ‘Unlocked’, continue at (Antenna alignment on page 8-10).

Antenna alignment

Repeat the Antenna Alignment procedure as described Aligning antennas on page 6-100.

Check the receive power from the RSSI connector of the ODU.

If the receive power level is very small or cannot be measured, continue at Check transmit and receive frequencies on page 8-11.

If the receive power is close to the predicted power for the link then continue at Check link status on page 8-11.

Page 549: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Trouble establishing a wireless link

phn-2779_001v000 (Jul 2012) 8-11

Check transmit and receive frequencies

Check that the transmit frequency at the near end of the link is exactly equal to the receive frequency at the remote end of the link.

Check that the receive frequency at the near end of the link is exactly equal to the transmit frequency at the remote end of the link.

If this fails to resolve the problem, continue at Check waveguide and antennas

Check waveguide and antennas

Check the antennas, waveguides, RMKs and couplers for defects and incorrect assembly.

If this fails to resolve the problem replace the near end ODU and, if necessary, replace the remote ODU.

Check link status

If the receive signal power is close to the predicted value, check that the same channel bandwidth is configured for both ends of the link.

Page 550: Cambium network ptp 810 series 01 00 user guide

Trouble bridging Ethernet data traffic Chapter 8: Troubleshooting

8-12 phn-2779_001v000 (Jul 2012)

Trouble bridging Ethernet data traffic

Perform this task if any problems are encountered when attempting to send Ethernet data traffic over an established wireless link.

The following are the most common factors that could cause this problem:

• Invalid local Ethernet connectivity

• Link is unlocked

• Incorrect VLAN configuration

• Mismatch in 2+0 East/East ODU connections

• Loop among the link (links)

To investigate and correct Ethernet data traffic problems, proceed as follows::

1 Ensure that the IP devices that connect to the MMU payload Ethernet ports have good physical Ethernet connectivity.

2 Ensure that the “duplex” and “port speed” configuration of the MMU payload port are compatible with the IP devices connected. If the “port speed” of the MMU is configured to be GigE only, while the IP device attached can only support 100 Mbps, there will not be a valid Ethernet connection in between.

3 Ensure that the link is “Locked” by viewing the status panel of local unit and remote unit from the management web page.

4 If VLAN is enabled, ensure that VLAN is properly configured on both near end and remote end units.

Page 551: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Trouble bridging Ethernet data traffic

phn-2779_001v000 (Jul 2012) 8-13

5 For any 2+0 configuration, ensure that there is no payload data Ethernet loop. This means that the following should be properly configured and enabled:

a. port forwarding,

b. RSTP or

c. 2+0 trunk mode.

If none of the above is configured, there will be a loop as shown:

6 In a 2+0 configuration, it is possible that the links are locked but the connections of the ODUs are mismatched. For example, Near End East ODU is locked with Far End West ODU. This will cause a very high traffic error rate. Avoid the following incorrect connection:

To identify this incorrect connection, check the “status panel” of the MMU GUI which shows the RF frequency used for EAST and WEST ODUs. If the EAST ODU Tx frequency of one end is the same as the WEST ODU Rx Frequency of the other end, there is a mismatched configuration. If the mismatched configuration is as shown in the above diagram, fix the problem by switching the IF cables at the MMU.

Page 552: Cambium network ptp 810 series 01 00 user guide

Trouble bridging Ethernet data traffic Chapter 8: Troubleshooting

8-14 phn-2779_001v000 (Jul 2012)

7 Loopback test mode or BERT mode may block payload Ethernet data. When loopback test to local modem is enabled, no Ethernet data will be sent across the link. Therefore, ensure that loopback test mode to local modem is disabled. Also ensure that BERT test mode is not running.

Page 553: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Trouble bridging E1/T1 traffic

phn-2779_001v000 (Jul 2012) 8-15

Trouble bridging E1/T1 traffic

Perform this task if any problems are experienced with E1/T1 channels in a newly installed (or operational) link.

Check for proper configuration and connectivity

To confirm that the E1/T1 link is correctly configured and connected, proceed as follows:

1 View the Status Panel to verify that the RF link is locked.

2 Verify that the channel map is correct. Make sure that the syntax is correct and that all channels configured during the link configuration are mapped.

3 Check to be sure the E1/T1 cable connections between the MMU and the network equipment are connected and not damaged.

4 Perform a loopback test to help diagnose the failure point (see Performing a loopback test on page 8-15). Local LIU loopback helps to prove that the local E1/T1 connection is good. Remote LIU loopback helps to prove that the connection from the local E1/T1 port all the way to the remote loopback point is good.

Performing a loopback test

Loopback tests are described in Loopback on page 1-62. They may only be performed by an administrator.

To perform a loopback test, select menu option Analysis, Loopback. The Loopback page is displayed (Figure 184). Select loopback requirements (Table 274) and select Start.

To stop a loopback test, select Stop.

Page 554: Cambium network ptp 810 series 01 00 user guide

Trouble bridging E1/T1 traffic Chapter 8: Troubleshooting

8-16 phn-2779_001v000 (Jul 2012)

Figure 184 Loopback page

Page 555: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Trouble bridging E1/T1 traffic

phn-2779_001v000 (Jul 2012) 8-17

Table 274 Loopback attributes

Attribute Meaning

Loopback Type The component where Loopback should been enabled. The options are:

Local LIU

Local Modem

Local ODU - Not supported

Remote LIU

The Local Modem option will affect Ethernet traffic: the network management connection to the remote unit will be disrupted.

Loopback LIU Type The LIU to be configured in Loopback when the Loopback type selected is Local LIU or Remote LIU. The options are:

E1 - Enable loopback on the E1/T1 LIU. The GUI will always show “E1”, whether the T1/E1 interface is configured to be T1 or E1.

STM1- Enable loopback on the STM1 LIU. Requires STM1 capable hardware to be installed on the MMU.

Both - Enable loopback on the E1/T1 and STM1 LIU. Requires STM1 capable hardware to be installed on the MMU.

Loopback ODU Type This option is not supported.

Loopback Duration Select the duration for which Loopback should be enabled. The loopback is disabled when the loopback duration expires.

Loopback Status Displays the current Loopback status of the various components.

Start Enable Loopback on the component selected.

Stop Disable Loopback on the component selected. Loopback is disabled immediately even if the Loopback duration has not expired.

Page 556: Cambium network ptp 810 series 01 00 user guide

Trouble bridging E1/T1 traffic Chapter 8: Troubleshooting

8-18 phn-2779_001v000 (Jul 2012)

BERT mode

Use BERT mode as a diagnostic tool to measure bit error rate over the link without external test equipment. In BERT mode, the user communicates with the MODEM directly by sending a command and receiving the response.

When BERT mode is enabled, the link will be disrupted and the remote MMU will not be accessible.

As there is no separate NMS stream when operating in BERT mode, the BERT mode has to be enabled independently at both ends of the link. This requires the use of two PCs, one connected directly to the NMS port of each MMU.

BERT mode may only be accessed by an administrator.

To start BERT testing, proceed as follows:

1 Obtain two PCs. Connect one PC to the NMS port of one MMU, and the other PC to the NMS port of the other MMU.

2 Select menu option Analysis, BERT Mode. The BERT mode page is displayed (Figure 185).

3 Enable BERT mode at one MMU by selecting East Enable or West Enable.

After few seconds (depending on network speed) the response from MODEM for the given command will be displayed in the text area.

4 Enabling this mode will generate random data over the link causing the other MMU to trigger the buzzer, generating noise. To silence the buzzer noise, enable BERT mode at the other MMU.

5 Monitor the attributes (Table 275). Use the scroll bar to view all messages in the text area. Every new response message is appended to the end of the list.

6 To reset the cumulative bits, cumulative bit errors, and bit error rate counters:

a. Select Clear at both MMUs.

b. After few seconds (depending on network speed) the response from MODEM for the given command will be displayed in the text area.

7 To insert an error and see whether the modem catches it, select Insert Bit Error.

To stop BERT testing, disable BERT mode at one MMU by selecting East Disable or West Disable. This will cause this MMU to generate a buzzer noise. Disable BERT mode at the other MMU. This should silence the buzzer noise.

Page 557: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide Trouble bridging E1/T1 traffic

phn-2779_001v000 (Jul 2012) 8-19

Figure 185 BERT Mode page

Table 275 BERT Mode attributes

Attribute Meaning

Text area Displays the response messages from the MODEM.

Cumulative Bits (*) Total number of bits.

Cumulative Bit Error (*)

Total number of error bits.

Bit Error Rate (*) Percentage of error bits.

(*) These are accumulated until the BERTs are disabled, or the MMUs are power cycled, which will clear the BERT mode.

Page 558: Cambium network ptp 810 series 01 00 user guide

Trouble managing remote unit Chapter 8: Troubleshooting

8-20 phn-2779_001v000 (Jul 2012)

Trouble managing remote unit

Perform this task if any problems are encountered when trying to manage the remote unit.

To investigate and correct problems with remote unit management, proceed as follows::

1 Verify that the remote unit can be reached by pinging the IP address of the remote unit.

2 If the remote unit can be pinged, continue at Trouble connecting to the web management interface on page 8-2.

3 If the remote unit cannot be pinged, verify that the wireless link is successfully established (locked). If the wireless link is not successfully established, continue at Trouble establishing a wireless link on page 8-8.

4 If the wireless link is locked, ensure that no Ethernet loop is present in the network. Ensure that RSTP is turned on for network management from the local unit.

5 Ensure that the link is not running any test mode, such as loopback test mode or BERT test mode.

Page 559: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide

phn-2779_001v000 (Jul 2012) I

Glossary

Term Definition

ACM Adaptive Coding/Modulation

AES Advanced Encryption Standard

AIS Alarm Indication Signal

APC Adaptive Power Control

APS Automatic Protection Switch

ARP Address Resolution Protocol

ATPC Automatic Transmitter Power Control

AWG American Wire Gage

BER Bit Error Rate

BERT Bit Error Rate Test

CEPT European Conference of Postal and Telecommunications Administrations

CER Channel Error Rate

CIST Common and Internal Spanning Tree

CLI Command Line Interface

CPU Central Processing Unit

CST Common Spanning Tree

DES Data Encryption Standard

DHCP Dynamic Host Configuration Protocol

DOW Data Orderwire

DSCP Differentiated Services Code Point

DTF Distance To Fault

EIRP Equivalent Isotropic Radiated Power

EMC Electromagnetic compatibility

EMD Electromagnetic discharge

ETSI European Telecommunications Standards Institute

FCC Federal Communications Commission

Page 560: Cambium network ptp 810 series 01 00 user guide

Glossary

II phn-2779_001v000 (Jul 2012)

Term Definition

FE Fast Ethernet

FEC Forward Error Correction

FPGA Field Programmable Gate Array

FTP File Transfer Protocol

GUI Graphical User Interface

HSB Hot Standby

HT High Transmit frequency

HTTP Hypertext Transfer Protocol

HTTPS (SSL)

HTTP over Secure Sockets Layer

IC Industry Canada

ICMP Internet Control Message Protocol

ID Identity

IDU Indoor Unit

IEEE Institute of Electrical and Electronic Engineers

IF Intermediate Frequency

I/O Input/Output

IP Internet Protocol

ITU International Telecommunications Union

LACP Link Aggregation Control Protocol

LAN Local Area Network

LED Light Emitting Diode

LIU Line Interface Unit

LOS Loss Of Signal

LPU Lightning Protection Unit

LT Low Transmit frequency

MAC Medium Access Control Layer

MD5 Message Digest Algorithm

MIB Management Information Base

MMU Modular Modem Unit

Page 561: Cambium network ptp 810 series 01 00 user guide

PTP 810 Series User Guide

phn-2779_001v000 (Jul 2012) III

Term Definition

MPLS Multi-Protocol Label Switching

MSTP Multiple Spanning Tree Protocol

NMS Network Management Server

NTP Network Time Protocol

ODU Outdoor Unit

OMK Orthogonal Mounting Kit

OMT Orthogonal Mode Transducer

PC IBM Compatible Personal Computer

PDH Plesiochronous Digital Hierarchy

PING ICMP Echo Request

PTP Point-to-Point

QAM Quadrature Amplitude Modulation

QoS Quality of Service

QPSK Quadrature Phase Shift Keying

RMK Remote Mounting Kit

RF Radio Frequency

RSL Receive Signal Level

RSSI Received Signal Strength Indication

RSTP Rapid Spanning Tree Protocol

SD Spatial Diversity

SDH Synchronous Digital Hierarchy

SDIDU Alternative term for MMU

SELV Safety Extra Low Voltage

SFP Small Form-factor Pluggable

SMTP Simple Mail Transfer Protocol

SNCP Sub-Network Connection Protection

SNMP Simple Network Management Protocol

SNR Signal to Noise Ratio

SNTP Simple Network Time Protocol

SSH Secure Shell

Page 562: Cambium network ptp 810 series 01 00 user guide

Glossary

IV phn-2779_001v000 (Jul 2012)

Term Definition

STM Synchronous Transport Module

STP Spanning Tree Protocol

TCP Transmission Control Protocol

TDM Time Division Multiplexing

TPID Tag Protocol Identifier

UNI User-Network Interface

UV Ultraviolet

VID VLAN Identifier

VLAN Virtual Local Area Network

VSWR Voltage Standing Wave Ratio

XPI Cross-Polar Interference

XPIC Cross-Polar Interference Cancellation

Page 563: Cambium network ptp 810 series 01 00 user guide

phn-2779_001v000 (Jul 2012) V

Alarms

PTP 810 system alarms are described in the following pages.

Page 564: Cambium network ptp 810 series 01 00 user guide

PTP 810 MMU Alarms

Alarms‐1

Alarm Affected

Component Description LED to RED Alarm

Code Severity Modem Fault Lower

Modem The specified Modem cardhas indicated a fault. Fault detection is via reading Modem Hardware Status from MODEM during start- up and polling GPIO for MODEM fault indication. Polling interval 5 sec.

Modem Lower 11 Critical

Modem Comm Failure Lower

Modem The Controller Card isunable to communicate with the specified Modem card.

Modem Lower 12 Critical

Modem Card Removed Lower

Modem The specified Modem cardhas been removed from the IDU (only if the specified Modem card has been enabled for use). Fault detection via card-detect logic. Alarm is raised then lowered.

N/A 13 Major

Remote Fault East

Remote Fault West

T1E1 Expansion IO Test Mode

Link Reconfigured

Page 565: Cambium network ptp 810 series 01 00 user guide

PTP 810 MMU Alarms

Alarms‐2

Alarm Affected

Component Description LED to RED Alarm

Code Severity Modem Card Installed Lower

Modem The specified Modem cardhas been installed into the IDU (only if the specified Modem card is not enabled for use). Fault detection via card-detect logic. Alarm is raised then lowered.

N/A 14 Info

Modem Unlock Lower

Modem The demodulation functionalcomponents of the modem have lost lock to the incoming signal. The data received through the RF link is not valid. Fault detection via modem status polling. Polling interval: 1 sec.

N/A N/A Critical

RSL Low Lower Modem RSSI is approaching theminimum operational level of the link as set during configuration. Fault detection via modem status polling, comparing RSSI value to threshold value in configuration table. Polling interval 5 sec.

N/A N/A Major

Synthesizer Unlock Lower

Modem Modem synthesizer hasunlocked. Fault detection via modem status polling. Polling is done in conjunction with Modem Unlock polling.

N/A N/A Critical

SNR Low Lower Modem The signal-to-noise ratio isbelow the minimum operational level of the link as set during configuration. Fault detection via modem status polling, comparing Eb/No value to threshold value in configuration table. Polling interval 5 sec.

N/A N/A Major

Modem Fault Upper

Modem The specified Modem cardhas indicated a fault. Fault detection is via reading Modem Hardware Status from MODEM during start- up and polling GPIO for MODEM fault indication. Polling interval 5 sec.

Modem Upper 16 Critical

Page 566: Cambium network ptp 810 series 01 00 user guide

PTP 810 MMU Alarms

Alarms‐3

Alarm Affected

Component Description LED to RED Alarm

Code Severity Modem Comm Failure Upper

Modem The Controller Card isunable to communicate with the specified Modem card.

Modem Upper 17 Critical

Modem Card Removed Upper

Modem The specified Modem cardhas been removed from the IDU (only if the specified Modem card has been enabled for use). Fault detection via card-detect logic. Alarm is raised then lowered.

N/A 18 Major

Modem Card Installed Upper

Modem The specified Modem cardhas been installed into the IDU (only if the specified Modem card is not enabled for use). Fault detection via card-detect logic. Alarm is raised then lowered.

N/A 19 Info

Modem Unlock Upper

Modem The demodulation functionalcomponents of the modem have lost lock to the incoming signal. The data received through the RF link is not valid. Fault detection via modem status polling. Polling interval 1 sec.

N/A N/A Critical

RSL Low Upper Modem RSSI is approaching theminimum operational level of the link as set during configuration. Fault detection via modem status polling, comparing RSSI value to threshold value in configuration table. Polling interval 5 sec.

N/A N/A Major

SNR Low Upper Modem The signal-to-noise ratio isbelow the minimum operational level of the link as set during configuration. Fault detection via modem status polling, comparing Eb/N0 value to threshold value in configuration table. Polling interval 5 sec.

N/A N/A Major

Page 567: Cambium network ptp 810 series 01 00 user guide

PTP 810 MMU Alarms

Alarms‐4

Alarm Affected

Component Description LED to RED Alarm

Code Severity Synthesizer Unlock Upper

Modem Modem synthesizer hasunlocked. Fault detection via modem status polling. Polling is done in conjunction with Modem Unlock polling.

N/A N/A Critical

Fan Failure x Controller The Fan rotational speed istoo low. (Controller card LED flashed red rather than orange). Fault detection via polling fan controller status. The fan number shall be included in the Alarm message. Polling interval 3 sec.

Controller 21 Major

Controller Card Fault

Controller The CPU has detected afault in the controller card. (Controller card LED flashes red rather than orange). Fault detection via software.

Controller 22 Critical

Low Battery Voltage

Controller The CPU has detected alow-battery voltage condition. (Controller card LED flashes red rather than orange). Fault detection via software polling RTC via controller FPGA.

Controller 23 Info

Power Supply Fault Lower

Power Supply The Power Supply card hasindicated a fault. Fault detection via polling GPIO. Polling interval 5 sec.

N/A 31 Critical

Power Supply Card Removed Lower

Power Supply The specified Power Supplycard has been removed from the IDU. Fault detection via card-detect logic.

N/A 32 Major

Power Supply Fault Upper

Power Supply The Power Supply card hasindicated a fault. Fault detection via polling GPIO. Polling interval 5 sec.

N/A 36 Critical

Power Supply Card Removed Upper

Power Supply The specified Power Supplycard has been removed from the IDU. Fault detection via card-detect logic.

N/A 37 Major

Page 568: Cambium network ptp 810 series 01 00 user guide

PTP 810 MMU Alarms

Alarms‐5

Alarm Affected

Component Description LED to RED Alarm

Code Severity Standard I/O Card Removed

MstIO The Standard I/O card hasbeen removed from the IDU. Fault detect via card-detect logic.

N/A 41 Critical

Ethernet Payload Disconnect Port x

MstIO There is no cable detectedat the specified Ethernet payload port on I/O card (only if Ethernet mode enabled). Fault detection via polling of Ethernet PHY. Polling interval 5 sec.

Standard I/O 42 Critical

Mini I/O Card Removed

MiniIO The Mini I/O card has beenremoved from the IDU (only if Mini I/O card has been enabled for use). Fault detection via card-detect logic.

Standard I/O 46 Critical

Mini I/O Card Installed

MiniIO The Mini I/O card has beeninstalled into the IDU (only if Mini I/O card is noted enabled for use). Fault detection via card-detect logic. Alarm is raised then lowered.

Standard I/O 47 Info

Expansion I/O Card Removed

ExpIO The Expansion I/O card hasbeen removed from the IDU (only if the Expansion I/O card has been enabled for use). Fault detection via card-detect logic.

N/A 26 Critical

Expansion I/O Card Installed

ExpIO The Expansion I/O card hasbeen installed into the IDU (only if the Expansion I/O card is not enabled for use). Fault detection via card- detect logic. Alarm is raised then lowered.

Expansion I/O 27 Info

Page 569: Cambium network ptp 810 series 01 00 user guide

PTP 810 MMU Alarms

Alarms‐6

Alarm Affected

Component Description LED to RED Alarm

Code Severity T1E1 [Master, Expansion] IO x Disconnect

MstIO (1-42) ExpIO (1-21)

There is either no cabledetected at the specified E1/ T1 channel port on Standard I/O Card or there is an AIS condition detected (only for active T1/E1 channels). Fault detection via polling of LIUs on Standard I/O card and Expansion I/O Card when installed. Polling interval 2 channels per 1 sec. Report of this alarm in the GUI/Syslog/Alarm history shall indicate whether this is a disconnect or AIS condition. If both conditions are present, then the disconnect alarm shall take precedence over the AIS alarm. If the alarms masked, both disconnect and AIS conditions are masked

Turn LED orange rather than RED on Master I/O

51-58 (1-16)

61-68

(17-32)

Critical

T1/E1 Test Mode

MstIO The user has selected a T1/E1 test mode (loopback or TX Data). This alarm shall be set when the user sets the testmode for any of the T1/E1 channels, and cleared when all T1/E1 channels are not in loopback and TX Data is normal.

N/A 59 Info

BERT/LB/CW Test Mode

MstIO This alarm shall be set whenthe user enables either BERT, Loopback, or CW mode, and cleared when all BERT, Loopback and CW modes are disabled.

N/A 69 Info

Page 570: Cambium network ptp 810 series 01 00 user guide

PTP 810 MMU Alarms

Alarms‐7

Alarm Affected

Component Description LED to RED Alarm

Code Severity ODU Fault Lower

ODU The ODU has indicated afault condition. Fault detection via polling of ODU or unsolicited message, if supported. Polling interval 5 sec. Polling done via API functional call. Report of this alarm in the GUI/Syslog/ Alarm history shall indicate the fault code from the ODU.

N/A 71 Critical

ODU Comm Failure Lower

ODU The IDU is unable tocommunicate with the ODU. This could be a problem with the ODU or a problem with the cable connecting the ODU to the IDU.

N/A 72 Critical

ODU Fault Upper

ODU The ODU has indicated afault condition or unsolicited message, if supported. Fault detection via polling of ODU. Polling interval 5 sec. Polling done via API function call. Report of this alarm in the GUI/Syslog/ Alarm history shall indicate the fault code from the ODU.

N/A 73 Critical

ODU Comm Failure Upper

ODU The IDU is unable tocommunicate with the ODU. This could be a problem with the ODU or a problem with the cable connecting the ODU to the IDU.

N/A 74 Critical

Protection Switch

MODEM/ODU This alarm shall be set whenan AL1 command is received from the active MODEM/ODU, then cleared when an AL2 command is received from the standby MODEM/ODU. Report of this alarm in the GUI/Syslog/ Alarm history shall indicate the fault code from the ODU, if received.

N/A 75 Major

Page 571: Cambium network ptp 810 series 01 00 user guide

PTP 810 MMU Alarms

Alarms‐8

Alarm Affected

Component Description LED to RED Alarm

Code Severity East ATPC TX at Max Power

ODU The IDU is unable toincrease the TX Power as requested by link partner due to maximum power being reached. Maximum power is specified in the configuration table.

N/A 76 Info

West ATPC TX at Max Power

ODU The IDU is unable toincrease the TX Power as requested by link partner due to maximum power being reached. Maximum power is specified in the configuration table.

N/A 78 Info

Link Fault IDU Failed to receive linkheartbeat from link partner via Radio Overhead (ROH) channel. Fault detection via timeout counter, which is reset via reception of link heartbeat message.

N/A 81 Critical

Encryption Failure

IDU Data is not being decryptedproperly due to encryption key mismatch between link partners. Fault detection via software detection of unreadable ROH messages from link partner.

N/A 83 Critical

Encryption OneWay

IDU Only one IDU has dataencryption enabled. Fault detection via software messages to/from link partner.

N/A 84 Major

External Alarm 1 External The external Alarm 1 inputhas been activated. Fault detection via polling GPIO. Polling interval 1 sec.

N/A 91 Info

External Alarm 2 External The external Alarm 2 inputhas been activated. Fault detection via polling GPIO. Polling interval 1 sec.

N/A 92 Info

Page 572: Cambium network ptp 810 series 01 00 user guide

PTP 810 MMU Alarms

Alarms‐9

Alarm Affected

Component Description LED to RED Alarm

Code Severity External Alarm 3 External The external Alarm 3 input

has been activated. Fault detection via polling GPIO. Polling interval 1 sec.

N/A 93 Info

External Alarm 4 External The external Alarm 4 inputhas been activated. Fault detection via polling GPIO. Polling interval 1 sec.

N/A 94 Info

Remote IDU Alarm

Link Partner IDU

The link partner IDU hasindicated an alarm condition via ROH.

N/A 95 Major

Remote IDU External Alarm 1

Link Partner External

The link partner IDU hasindicated via ROH its external alarm input 1 has been activated.

N/A 96 Info

Remote IDU External Alarm 2

Link Partner External

The link partner IDU hasindicated via ROH its external alarm input 2 has been activated.

N/A 97 Info

Remote IDU External Alarm 3

Link Partner External

The link partner IDU hasindicated via ROH its external alarm input 3 has been activated.

N/A 98 Info

Remote IDU External Alarm 4

Link Partner External

The link partner IDU hasindicated via ROH its external alarm input 4 has been activated.

N/A 99 Info

STM Loss of Clock

IDU The SDH/SONET clock haslost lock. Fault detection via polling of LIU.

N/A Solid Critical

STM Loss of Signal

IDU The SDH/SONET has aLoss of Signal Defect. Fault detection via polling of LIU.

N/A Solid Critical

STM RS_B1 IDU The SDH/SONET Mux/Demux has a B1 Defect. Fault detection via polling of RS_B1_T bit in STM-1 Core. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Major

STM RS_LOF IDU The SDH/SONET Mux/Demux has a Loss of Frame Defect. Fault detection via polling of RS_LOF_T bit in STM-1 Core. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Critical

Page 573: Cambium network ptp 810 series 01 00 user guide

PTP 810 MMU Alarms

Alarms‐10

Alarm Affected

Component Description LED to RED Alarm

Code Severity STM RS_OOF IDU The SDH/SONET Mux/

Demux has a Out of Frame Defect. Fault detection via polling of RS_OOF_T bit in STM-1 Core. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Critical

STM RS_TIM IDU The SDH/SONET Mux/Demux has a Trace Identifier Mismatch Defect. Fault detection via polling of RS_TIM_T bit in STM-1 Core. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Major

STM MS-AIS IDU The SDH/SONET Mux/Demux has detected an AIS at the Multiplexer Level. Fault detection via polling of MS_AIS_T bit in STM-1 Core. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Critical

STM MS-REI IDU The SDH/SONET Mux/Demux has detected a Remote Error at the Multiplexer Level. Fault detection via polling of MS_REI_T bit in STM-1 Core. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Major

STM MS-RDI IDU The SDH/SONET Mux/Demux has detected an Remote Defect at the Multiplexer Level. Fault detection via polling of MS_RDI_T bit in STM-1 Core. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Major

Page 574: Cambium network ptp 810 series 01 00 user guide

PTP 810 MMU Alarms

Alarms‐11

Alarm Affected

Component Description LED to RED Alarm

Code Severity STM MS_B2 IDU The SDH/SONET Mux/

Demux has a B2 Defect at the Multiplex level. Fault detection via polling of MS_B2_T bit in STM-1 Core. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Major

STM AU-AIS IDU The SDH/SONET Mux/Demux has detected an AIS at the AU Level. Fault detection via polling of AU_AIS_T bit in STM-1 Core. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Critical

STM AU-LOP IDU The SDH/SONET Mux/Demux has detected an Loss of Pointer Defect at the AU Level. Fault detection via polling of AU_LOP_T bit in STM-1 Core. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Critical

STM HP-UNEQ IDU The SDH/SONET Mux/Demux HP is Unequipped. Fault detection via polling of HP_UNEQ_T bit in STM-1 Core. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Major

STM HP-TIM IDU The SDH/SONET Mux/Demux HP has a Trace Identifier Mismatch. Fault detection via polling of HP_TM_TIM_T bit in STM-1 Core. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Major

STM HP-REI IDU The SDH/SONET Mux/Demux HP has a Remote Error Indication. Fault detection via polling of HP_REI_T bit in STM-1 Core. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Major

Page 575: Cambium network ptp 810 series 01 00 user guide

PTP 810 MMU Alarms

Alarms‐12

Alarm Affected

Component Description LED to RED Alarm

Code Severity STM HP-RDI IDU The SDH/SONET Mux/

Demux HP has a Remote Defect Indication. Fault detection via polling of HP_RDI_T bit in STM-1 Core. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Major

STM HP-PLM IDU The SDH/SONET Mux/Demux HP has a Path Identifier Mismatch. Fault detection via polling of HP_PLM_T bit in STM-1 Core. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Critical

STM HP_B3 IDU The SDH/SONET Mux/Demux HP has a CRC Error. Fault detection via polling of HP_B3_T bit in STM-1 Core. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Major

STM TU-LOM lkm

IDU The SDH/SONET Mux/Demux TU number ‘x’ has a Loss of Multiframe. Fault detection via polling of TU_LOMF_T bit in STM-1 Core. Where ‘lkm’ is the TU index as LKM numbering. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Critical

STM TU-AIS lkm IDU The SDH/SONET Mux/Demux TU number ‘x’ has an AIS. Fault detection via polling of TU_AIS_T bit in STM-1 Core. Where ‘lkm’ is the TU index as LKM numbering. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Critical

Page 576: Cambium network ptp 810 series 01 00 user guide

PTP 810 MMU Alarms

Alarms‐13

Alarm Affected

Component Description LED to RED Alarm

Code Severity STM TU-LOP lkm

IDU The SDH/SONET Mux/Demux TU number ‘x’ has a Loss of Pointer Defect. Fault detection via polling of TU_LOP_T bit in STM-1 Core. Where ‘lkm’ is the TU index as LKM numbering. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Critical

STM LP-UNEQ lkm

IDU The SDH/SONET Mux/Demux LP number ‘x’ is Unequipped. Fault detection via polling of LP_UNEQ_T bit in STM-1 Core. Where ‘lkm’ is the LP index as LKM numbering. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Major

STM LP-TIM lkm IDU The SDH/SONET Mux/Demux LP number ‘x’ has a Trace Identifier Mismatch. Fault detection via polling of LP_TM_TIM_T bit in STM-1 Core. Where ‘lkm’ is the LP index as LKM numbering. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Major

STM LP-REI lkm IDU The SDH/SONET Mux/Demux LP number ‘x’ has a Remote Error Indication. Fault detection via polling of LP_REI_T bit in STM-1 Core. Where ‘lkm’ is the LP index as LKM numbering. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Major

Page 577: Cambium network ptp 810 series 01 00 user guide

PTP 810 MMU Alarms

Alarms‐14

Alarm Affected

Component Description LED to RED Alarm

Code Severity STM LP-RDI lkm IDU The SDH/SONET Mux/

Demux LP number ‘x’ has a Remote Defect Indication. Fault detection via polling of LP_RDI_T bit in STM-1 Core. Where ‘lkm’ is the LP index as LKM numbering. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Major

STM LP-PLM lkm

IDU The SDH/SONET Mux/Demux LP number ‘x’ has a Path Identifier Mismatch. Fault detection via polling of LP_PLM_T bit in STM-1 Core. Where ‘lkm’ is the LP index as LKM numbering. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Critical

STM LP-RFI lkm IDU The SDH/SONET Mux/Demux LP number ‘x’ has a Remote Fault Indication. Fault detection via polling of LP_RFI_T bit in STM-1 Core. Where ‘lkm’ is the LP index as LKM numbering. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Critical

STM LP-BIP2 lkm

IDU The SDH/SONET Mux/Demux LP number ‘x’ has a CRC Error. Fault detection via polling of LP_BIP2_T bit in STM-1 Core. Where ‘lkm’ is the LP index as LKM numbering. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Major

SDIDU Power- Up

IDU During power-up raise thenlower this alarm.

N/A Solid Info

SDIDU Re-boot IDU When a user reboots theMMU, raise then lower this alarm prior to re-booting.

N/A Solid Info

Page 578: Cambium network ptp 810 series 01 00 user guide

PTP 810 MMU Alarms

Alarms‐15

Alarm Affected

Component Description LED to RED Alarm

Code Severity NTP Update IDU When the system time is

updated via NTP raise then lower this alarm. The previous system time and new system time should be noted in the alarm log, snmp trap, and syslog messages.

N/A Solid Info

Master IO FPGA Mismatch

IDU When the FPGA image(s)does not match the installed Master IO card, this alarm shall be set.

N/A Solid Critical

FPGA Programming Failure

IDU When the FPGAprogramming fails, this alarm shall be set.

N/A Solid Critical

Receive Protection Switch

IDU It informs the user that areceive side protection switch has occurred. There are no user controls for a receive protection switch. The framer is always receiving from both east and west modems in a 1+1 configuration and may switch active receivers if the quality is better on one side versus the other.

N/A Solid Info

Page 579: Cambium network ptp 810 series 01 00 user guide

PTP 810 MMU Alarms

Alarms‐16

Alarm Affected

Component Description LED to RED Alarm

Code Severity East PDH Protection Switch

IDU When the FPGA initiates aPDH Ring Protection Switch this Alarm shall be set. The FPGA alarms bits shall be polled every 1 second, and the Alarm raised when the alarm bits are set, and cleared when the alarm bits are cleared.

N/A Solid Major

West PDH Protection Switch

IDU When the FPGA initiates aPDH Ring Protection Switch this Alarm shall be set. The FPGA alarms bits shall be polled every 1 second, and the Alarm raised when the alarm bits are set, and cleared when the alarm bits are cleared.

N/A Solid Major

ODU Alarm 1 ODU When the ODU sends afault message, this alarm will correspond to bit 0 of the alarm message. This alarm will be set when the bit is active, and reset when the bit is inactive. The ODU fault status will be polled at 5 second intervals, as well as spontaneous ODU messages. Text describing the alarm type from the ODU library shall be added to the alarm text in the active alarms and alarm history.

N/A Solid Major

Page 580: Cambium network ptp 810 series 01 00 user guide

PTP 810 MMU Alarms

Alarms‐17

Alarm Affected

Component Description LED to RED Alarm

Code Severity ODU Alarm 2 ODU When the ODU sends a

fault message, this alarm will correspond to bit 1 of the alarm message. This alarm will be set when the bit is active, and reset when the bit is inactive. The ODU fault status will be polled at 5 second intervals, as well as spontaneous ODU messages. Text describing the alarm type from the ODU library shall be added to the alarm text in the active alarms and alarm history.

N/A Solid Major

ODU Alarm 3 ODU When the ODU sends afault message, this alarm will correspond to bit 2 of the alarm message. This alarm will be set when the bit is active, and reset when the bit is inactive. The ODU fault status will be polled at 5 second intervals, as well as spontaneous ODU messages. Text describing the alarm type from the ODU library shall be added to the alarm text in the active alarms and alarm history.

N/A Solid Major

Page 581: Cambium network ptp 810 series 01 00 user guide

PTP 810 MMU Alarms

Alarms‐18

Alarm Affected

Component Description LED to RED Alarm

Code Severity ODU Alarm 4 ODU When the ODU sends a

fault message, this alarm will correspond to bit 3 of the alarm message. This alarm will be set when the bit is active, and reset when the bit is inactive. The ODU fault status will be polled at 5 second intervals, as well as spontaneous ODU messages. Text describing the alarm type from the ODU library shall be added to the alarm text in the active alarms and alarm history.

N/A Solid Major

ODU Alarm 5 ODU When the ODU sends afault message, this alarm will correspond to bit 4 of the alarm message. This alarm will be set when the bit is active, and reset when the bit is inactive. The ODU fault status will be polled at 5 second intervals, as well as spontaneous ODU messages. Text describing the alarm type from the ODU library shall be added to the alarm text in the active alarms and alarm history.

N/A Solid Major

Page 582: Cambium network ptp 810 series 01 00 user guide

PTP 810 MMU Alarms

Alarms‐19

Alarm Affected

Component Description LED to RED Alarm

Code Severity ODU Alarm 6 ODU When the ODU sends a

fault message, this alarm will correspond to bit 5 of the alarm message. This alarm will be set when the bit is active, and reset when the bit is inactive. The ODU fault status will be polled at 5 second intervals, as well as spontaneous ODU messages. Text describing the alarm type from the ODU library shall be added to the alarm text in the active alarms and alarm history.

N/A Solid Major

ODU Alarm 7 ODU When the ODU sends afault message, this alarm will correspond to bit 6 of the alarm message. This alarm will be set when the bit is active, and reset when the bit is inactive. The ODU fault status will be polled at 5 second intervals, as well as spontaneous ODU messages. Text describing the alarm type from the ODU library shall be added to the alarm text in the active alarms and alarm history.

N/A Solid Major

Page 583: Cambium network ptp 810 series 01 00 user guide

PTP 810 MMU Alarms

Alarms‐20

Alarm Affected

Component Description LED to RED Alarm

Code Severity ODU Alarm 8 ODU When the ODU sends a

fault message, this alarm will correspond to bit 7 of the alarm message. This alarm will be set when the bit is active, and reset when the bit is inactive. The ODU fault status will be polled at 5 second intervals, as well as spontaneous ODU messages. Text describing the alarm type from the ODU library shall be added to the alarm text in the active alarms and alarm history.

N/A Solid Major

ODU Alarm 9 ODU When the ODU sends afault message, this alarm will correspond to bit 8 of the alarm message. This alarm will be set when the bit is active, and reset when the bit is inactive. The ODU fault status will be polled at 5 second intervals, as well as spontaneous ODU messages. Text describing the alarm type from the ODU library shall be added to the alarm text in the active alarms and alarm history.

N/A Solid Major

Page 584: Cambium network ptp 810 series 01 00 user guide

PTP 810 MMU Alarms

Alarms‐21

Alarm Affected

Component Description LED to RED Alarm

Code Severity ODU Alarm 10 ODU When the ODU sends a

fault message, this alarm will correspond to bit 9 of the alarm message. This alarm will be set when the bit is active, and reset when the bit is inactive. The ODU fault status will be polled at 5 second intervals, as well as spontaneous ODU messages. Text describing the alarm type from the ODU library shall be added to the alarm text in the active alarms and alarm history.

N/A Solid Major

ODU Alarm 11 ODU When the ODU sends afault message, this alarm will correspond to bit 10 of the alarm message. This alarm will be set when the bit is active, and reset when the bit is inactive. The ODU fault status will be polled at 5 second intervals, as well as spontaneous ODU messages. Text describing the alarm type from the ODU library shall be added to the alarm text in the active alarms and alarm history.

N/A Solid Major

Page 585: Cambium network ptp 810 series 01 00 user guide

PTP 810 MMU Alarms

Alarms‐22

Alarm Affected

Component Description LED to RED Alarm

Code Severity ODU Alarm 12 ODU When the ODU sends a

fault message, this alarm will correspond to bit 11 of the alarm message. This alarm will be set when the bit is active, and reset when the bit is inactive. The ODU fault status will be polled at 5 second intervals, as well as spontaneous ODU messages. Text describing the alarm type from the ODU library shall be added to the alarm text in the active alarms and alarm history.

N/A Solid Major

ODU Alarm 13 ODU When the ODU sends afault message, this alarm will correspond to bit 12 of the alarm message. This alarm will be set when the bit is active, and reset when the bit is inactive. The ODU fault status will be polled at 5 second intervals, as well as spontaneous ODU messages. Text describing the alarm type from the ODU library shall be added to the alarm text in the active alarms and alarm history.

N/A Solid Major

Page 586: Cambium network ptp 810 series 01 00 user guide

PTP 810 MMU Alarms

Alarms‐23

Alarm Affected

Component Description LED to RED Alarm

Code Severity ODU Alarm 14 ODU When the ODU sends a

fault message, this alarm will correspond to bit 13 of the alarm message. This alarm will be set when the bit is active, and reset when the bit is inactive. The ODU fault status will be polled at 5 second intervals, as well as spontaneous ODU messages. Text describing the alarm type from the ODU library shall be added to the alarm text in the active alarms and alarm history.

N/A Solid Major

ODU Alarm 15 ODU When the ODU sends afault message, this alarm will correspond to bit 14 of the alarm message. This alarm will be set when the bit is active, and reset when the bit is inactive. The ODU fault status will be polled at 5 second intervals, as well as spontaneous ODU messages. Text describing the alarm type from the ODU library shall be added to the alarm text in the active alarms and alarm history.

N/A Solid Major

Page 587: Cambium network ptp 810 series 01 00 user guide

PTP 810 MMU Alarms

Alarms‐24

Alarm Affected

Component Description LED to RED Alarm

Code Severity ODU Alarm 16 ODU When the ODU sends a

fault message, this alarm will correspond to bit 15 of the alarm message. This alarm will be set when the bit is active, and reset when the bit is inactive. The ODU fault status will be polled at 5 second intervals, as well as spontaneous ODU messages. Text describing the alarm type from the ODU library shall be added to the alarm text in the active alarms and alarm history.

N/A Solid Major

SFP Module Installed

MstIO The SFP module has beeninstalled into the IDU (only if GigE card is installed). Fault detection via FPGA register read. Alarm is raised then lowered.

MstIO N/A Info

SFP Module Removed

MstIO The SFP module has beenremoved into the IDU (only if GigE card is installed). Fault detection via FPGA register read. Alarm is raised then lowered.

MstIO N/A Info

SFP Module TX Fault

MstIO The SFP module fault (onlyif GigE card is installed). Fault detection via FPGA register read. Alarm is raised until fault condition is cleared then lowered.

MstIO N/A Major

SFP Payload Disconnect

MstIO There is no cable detectedat the SFP module (only if Ethernet mode enabled and GigE card installed). Fault detection via polling of Ethernet PHY. Polling interval 5 sec.

MstIO N/A Critical

SDIDU Temperature out of Range

IDU The specified operatingtemperature of the MMU has exceeded the upper or lower temperature limit.

N/A N/A Info

Page 588: Cambium network ptp 810 series 01 00 user guide

PTP 810 MMU Alarms

Alarms‐25

Alarm Affected

Component Description LED to RED Alarm

Code Severity ODU East Temperature Out Of Range

ODU The specified operatingtemperature of the East ODU has exceeded the upper or lower temperature limit.

N/A N/A Info

ODU West Temperature Out Of Range

ODU The specified operatingtemperature of the West ODU has exceeded the upper or lower temperature limit.

N/A N/A Info

ODU MODE NOT AUTHORIZED

IDU When the system detectsthat the ODU operational mode is not authorized during bootup.

NA N/A Critical

IDU MODE NOT AUTHORIZED

IDU When the system detectsthat the IDU operational mode is not authorized during bootup.

NA N/A Critical

Application And ODU Image Mismatch

IDU When the system detectsthat there is a mismatch between the version of the Application and ODU Library, the alarm will be activated and the modem process will exit to avoid undesired system behavior

Controller N/A Critical

Page 589: Cambium network ptp 810 series 01 00 user guide

PTP 810 MMU Alarms

Alarms‐26

Alarm Affected

Component Description LED to RED Alarm

Code Severity

Adaptive Modulation Lower

IDU SET when an AdaptiveModulation/Coding switch occurred for the Lower Modem. The additional information with the alarm indicates the new mode when the alarm is SET and the old mode when the alarm is RESET.

Controller N/A Critical

Adaptive Modulation Upper

IDU SET when an AdaptiveModulation/Coding switch occurred for the Upper Modem. The additional information with the alarm indicates the new mode when the alarm is SET and the old mode when the alarm is RESET.

Controller N/A Critical

USB Key Missing

IDU SET when the USB Key isnot plugged in the Controller (only for CCM-4501). RESET when the USB Key is plugged in the Controller (only for CCM-4501). This alarm is generated when a USB key previously installed is removed. If the MMU is powered up without a USB key this alarm will not be generated.

Controller N/A Info

USB Key Fault IDU SET when the USB Keycannot be read or cannot be written or the content is not recognized ((it is not a Package File.) (Only for CCM-4501 Controller).

RESET when USB Key can be read or written or the content can be recognized Or RESET if ‘USB Key Missing’ alarm is SET (Only for CCM-4501 Controller).

Controller N/A Major

Page 590: Cambium network ptp 810 series 01 00 user guide

PTP 810 MMU Alarms

Alarms‐27

Alarm Affected

Component Description LED to RED Alarm

Code Severity

USB SW Key Mismatch

IDU SET when at least oneComponent version present in the USB Key is different from the version in the active bank of the related plugged unit or there is at least one unit whose component is not stored in the USB Key (Only for CCM-4501 Controller).

RESET when all Component versions present in the USB Key are the same as the version in the active bank of the related plugged unit or there is at least one unit whose component is not stored in the USB Key or RESET if ‘USB Key Missing’ alarm is SET or ‘USB Key Fault’ alarm is SET(Only for CCM-4501 Controller).

Controller N/A Major

USB Copy in- progress

IDU SET during the transferringof the software components contained in the USB Key to the system units (Only for CCM-4501 Controller).

RESET when copying is completed or ‘USB Key Missing’ alarm is SET (Only for CCM-4501 Controller).

Controller N/A Info

Exp STM MSP SD EXx(x=1,2)

ExpIO The Expansion STM MSPSignal degrades alarm for the front panel ports. SET when fault occurs in working path and RESET when it gets cleared.

ExpIO N/A Critical

Exp STM MSP SF Port EXx(x=1,2)

ExpIO The Expansion STM MSPSignal Failure alarm for the front panel ports. SET when fault occurs in working path and RESET when it gets cleared.

ExpIO N/A Critical

Page 591: Cambium network ptp 810 series 01 00 user guide

PTP 810 MMU Alarms

Alarms‐28

Alarm Affected

Component Description LED to RED Alarm

Code Severity

Exp STM SNCP SD EXx(x=A,B,C and D)

ExpIO The Expansion STM SNCPSignal degrades alarm for the channels present in the STM ADM Core. SET when fault occurs in working channels and RESET when it gets cleared.

ExpIO N/A Critical

Exp STM SNCP SF EXx(x=A,B,C and D)

ExpIO The Expansion STM SNCPSignal Failure alarm for the channels present in the STM ADM Core. SET when fault occurs in working channels and RESET when it gets cleared.

ExpIO N/A Critical

Exp’x’ STM Loss of Clock (x=Front Panel 1 and 2)

ExpIO The Expansion SDH/SONET clock has lost lock. Fault detection via polling of LIU.

N/A Solid Critical

Exp’x’ STM RS_LOS (x= Front Panel 1 and 2)

ExpIO The Expansion SDH/SONET has a Loss of Signal Defect. Fault detection via polling of LIU.

N/A Solid Critical

Exp STM RS_B1 EX’x’(x=ADM Core A,B,C, and D )

ExpIO The Expansion SDH/SONET Mux/Demux has a B1 Defect in the STM ADM Core. Fault detection via polling of RS_B1_T bit in STM-1 Core. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Major

Exp STM RS_LOF EX’x’(x= ADM Core A,B,C, and D)

ExpIO The Expansion SDH/SONET Mux/Demux has a Loss of Frame Defect in the STM ADM Core. Fault detection via polling of RS_LOF_T bit in STM-1 Core. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Critical

Page 592: Cambium network ptp 810 series 01 00 user guide

PTP 810 MMU Alarms

Alarms‐29

Alarm Affected

Component Description LED to RED Alarm

Code Severity Exp STM RS_OOF EX’x’(x=ADM Core A,B,C, and D)

ExpIO The Expansion SDH/SONET Mux/Demux has a Out of Frame Defect in the STM ADM Core. Fault detection via polling of RS_OOF_T bit in STM-1 Core. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Critical

Exp STM RS_TIM EX’x’(x=ADM Core A,B,C, and D)

ExpIO The Expansion SDH/SONET Mux/Demux has a Trace Identifier Mismatch Defect in the STM ADM Core. Fault detection via polling of RS_TIM_T bit in STM-1 Core. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Major

Exp STM MS- AIS EX’x’(x=ADM Core A,B,C, and D)

ExpIO The Expansion SDH/SONET Mux/Demux has detected an AIS at the Multiplexer Level in the STM ADM Core. Fault detection via polling of MS_AIS_T bit in STM-1 Core. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Critical

Exp STM MS- REI EX’x’(x=ADM Core A,B,C, and D)

ExpIO The Expansion SDH/SONET Mux/Demux has detected a Remote Error at the Multiplexer Level in the STM ADM Core. Fault detection via polling of MS_REI_T bit in STM-1 Core. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Major

Exp STM MS- RDI EX’x’(x=ADM Core A,B,C, and D)

ExpIO The Expansion SDH/SONET Mux/Demux has detected an Remote Defect at the Multiplexer Level in the STM ADM Core. Fault detection via polling of MS_RDI_T bit in STM-1 Core. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Major

Page 593: Cambium network ptp 810 series 01 00 user guide

PTP 810 MMU Alarms

Alarms‐30

Alarm Affected

Component Description LED to RED Alarm

Code Severity Exp STM MS_B2 EX’x’(x=ADM Core A,B,C, and D)

ExpIO The Expansion SDH/SONET Mux/Demux has a B2 Defect at the Multiplex level in the STM ADM Core. Fault detection via polling of MS_B2_T bit in STM-1 Core. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Major

Exp STM AU- AIS EX’x’(x=ADM Core A,B,C, and D)

ExpIO The Expansion SDH/SONET Mux/Demux has detected an AIS at the AU Level in the STM ADM Core. Fault detection via polling of AU_AIS_T bit in STM-1 Core. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Critical

Exp STM AU- LOP EX’x’(x=ADM Core A,B,C, and D)

ExpIO The Expansion SDH/SONET Mux/Demux has detected an Loss of Pointer Defect at the AU Level in the STM ADM Core. Fault detection via polling of AU_LOP_T bit in STM-1 Core. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Critical

Exp STM HP- UNEQ EX’x’(x=ADM Core A,B,C, and D)

ExpIO The Expansion SDH/SONET Mux/Demux HP is Unequipped in the STM ADM Core. Fault detection via polling of HP_UNEQ_T bit in STM-1 Core. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Major

Exp STM HP- TIM EX’x’(x=ADM Core A,B,C, and D)

ExpIO The Expansion SDH/SONET Mux/Demux HP has a Trace Identifier Mismatch in the STM ADM Core. Fault detection via polling of HP_TM_TIM_T bit in STM-1 Core. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Major

Page 594: Cambium network ptp 810 series 01 00 user guide

PTP 810 MMU Alarms

Alarms‐31

Alarm Affected

Component Description LED to RED Alarm

Code Severity Exp STM HP- REI EX’x’(x=ADM Core A,B,C, and D)

ExpIO The Expansion SDH/SONET Mux/Demux HP has a Remote Error Indication in the STM ADM Core. Fault detection via polling of HP_REI_T bit in STM-1 Core. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Major

Exp STM HP- RDI EX’x’(x=ADM Core A,B,C, and D)

ExpIO The Expansion SDH/SONET Mux/Demux HP has a Remote Defect Indication in the STM ADM Core. Fault detection via polling of HP_RDI_T bit in STM-1 Core. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Major

Exp STM HP- PLM EX’x’(x=ADM Core A,B,C, and D)

ExpIO The Expansion SDH/SONET Mux/Demux HP has a Path Identifier Mismatch in the STM ADM Core. Fault detection via polling of HP_PLM_T bit in STM-1 Core. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Critical

Exp STM HP_B3 EX’x’(x=ADM Core A,B,C, and D)

ExpIO The Expansion SDH/SONET Mux/Demux HP has a CRC Error in the STM ADM Core. Fault detection via polling of HP_B3_T bit in STM-1 Core. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Major

Exp STM TU- LOM EX’x’(x=ADM Core A,B,C, and D) lkm

ExpIO The Expansion SDH/SONET Mux/Demux TU has a Loss of Multiframe in the STM ADM Core. Fault detection via polling of TU_LOMF_T bit in STM-1 Core. Where ‘lkm’ is the TU index as LKM numbering. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Critical

Page 595: Cambium network ptp 810 series 01 00 user guide

PTP 810 MMU Alarms

Alarms‐32

Alarm Affected

Component Description LED to RED Alarm

Code Severity Exp STM TU- AIS EX’x’(x=ADM Core A,B,C, and D) lkm

ExpIO The Expansion SDH/SONET Mux/Demux TU has an AIS in the STM ADM Core. Fault detection via polling of TU_AIS_T bit in STM-1 Core. Where ‘lkm’ is the TU index as LKM numbering. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Critical

Exp STM TU- LOP EX’x’(x=ADM Core A,B,C, and D) lkm

ExpIO The Expansion SDH/SONET Mux/Demux TU has a Loss of Pointer Defect in the STM ADM Core. Fault detection via polling of TU_LOP_T bit in STM-1 Core. Where ‘lkm’ is the TU index as LKM numbering. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Critical

Exp STM LP- UNEQ EX’x’(x=ADM Core A,B,C, and D) lkm

ExpIO The Expansion SDH/SONET Mux/Demux LP is Unequipped in the STM ADM Core. Fault detection via polling of LP_UNEQ_T bit in STM-1 Core. Where ‘lkm’ is the LP index as LKM numbering. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Major

Exp STM LP- TIM EX’x’(x=ADM Core A,B,C, and D) lkm

ExpIO The Expansion SDH/SONET Mux/Demux LP has a Trace Identifier Mismatch in the STM ADM Core. Fault detection via polling of LP_TM_TIM_T bit in STM-1 Core. Where ‘lkm’ is the LP index as LKM numbering. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Major

Page 596: Cambium network ptp 810 series 01 00 user guide

PTP 810 MMU Alarms

Alarms‐33

Alarm Affected

Component Description LED to RED Alarm

Code Severity Exp STM LP- REI EX’x’(x=ADM Core A,B,C, and D) lkm

ExpIO The Expansion SDH/SONET Mux/Demux LP has a Remote Error Indication in the STM ADM Core. Fault detection via polling of LP_REI_T bit in STM-1 Core. Where ‘lkm’ is the LP index as LKM numbering. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Major

Exp STM LP- RDI EX’x’(x=ADM Core A,B,C, and D) lkm

ExpIO The Expansion SDH/SONET Mux/Demux LP has a Remote Defect Indication in the STM ADM Core. Fault detection via polling of LP_RDI_T bit in STM-1 Core. Where ‘lkm’ is the LP index as LKM numbering. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Major

Exp STM LP- PLM EX’x’(x=ADM Core A,B,C, and D) lkm

ExpIO The Expansion SDH/SONET Mux/Demux LP has a Path Identifier Mismatch in the STM ADM Core. Fault detection via polling of LP_PLM_T bit in STM-1 Core. Where ‘lkm’ is the LP index as LKM numbering. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Critical

Exp STM LP-RFI EX’x’(x=ADM Core A,B,C, and D) lkm

ExpIO The Expansion SDH/SONET Mux/Demux LP has a Remote Fault Indication in the STM ADM Core. Fault detection via polling of LP_RFI_T bit in STM-1 Core. Where ‘lkm’ is the LP index as LKM numbering. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Critical

Page 597: Cambium network ptp 810 series 01 00 user guide

PTP 810 MMU Alarms

Alarms‐34

Alarm Affected

Component Description LED to RED Alarm

Code Severity Exp STM LP- BIP2 EX’x’(x=ADM Core A,B,C, and D) lkm

ExpIO The Expansion SDH/SONET Mux/Demux LP has a CRC Error in the STM ADM Core. Fault detection via polling of LP_BIP2_T bit in STM-1 Core. Where ‘lkm’ is the LP index as LKM numbering. Alternate detection via Interrupt enabled in STM-1 core.

N/A Solid Major

Signal/XPI Threshold Low Lower

Modem The XPIC signal-to-crosspolarization interference ratio is below the minimum operational level of the link as set during configuration. ‘Lower’ is an indication of the modem card present in the lower position of the MMU chassis. Fault detection via modem status polling, comparing user configured threshold value with threshold value in configuration table. Polling interval 5 sec.

N/A N/A Major

Signal/XPI Threshold Low Upper

Modem The XPIC signal-to- crosspolarization interference ratio is below the minimum operational level of the link as set during configuration. ‘Upper’ is an indication of the modem card present in the upper position of the MMU chassis. Fault detection via modem status polling, comparing user configured threshold value with threshold value in configuration table. Polling interval 5 sec.

N/A N/A Major

Page 598: Cambium network ptp 810 series 01 00 user guide

PTP 810 MMU Alarms

Alarms‐35

Alarm Affected

Component Description LED to RED Alarm

Code Severity XPIC Unlock Lower

Modem XPIC is not providing cancellation, that is, XPIC has lost phase lock with the XPI signal. If this alarm is triggered when the Signal/XPI ratio is greater than 25 dB, the cross-polar interfering signal is too low to need to be cancelled and will not affect the operation of the link. Under this condition the alarm should be treated as informational only. Cancelling of the XPI signal usually occurs when the Signal/XPI ratio is between 10 and 25 dB. However, if the signals are impaired, for example due to high phase noise, then the alarm could be triggered, indicating a problem on the link. Equally, when the Signal/XPI ratio is below 10 dB, there is unlikely to be sufficient discrimination for effective cancellation and the alarm indicates a problem on the link. The Signal/XPI ratio is included in the Signal/Noise graph. ‘Upper’ / ‘Lower’ is an indication of the modem card location in the MMU chassis. Fault detection is done via modem status polling.

N/A N/A Major

XPIC Unlock Upper

Modem N/A N/A Major

XPIC Cable Disconnect Lower

Modem XPIC Loss of Link status ofthe modem card has unlocked indicating that the inter-modem hi-speed interface has been disconnected. ‘Lower’ is an indication of the modem card present in the lower position of the MMU chassis.

N/A N/A Major

Page 599: Cambium network ptp 810 series 01 00 user guide

PTP 810 MMU Alarms

Alarms‐36

Alarm Affected

Component Description LED to RED Alarm

Code Severity XPIC Cable Disconnect Upper

Modem XPIC Loss of Link status ofthe modem card has unlocked indicating that the inter-modem hi-speed interface has been disconnected. ‘Upper’ is an indication of the modem card present in the upper position of the MMU chassis.

N/A N/A Major

Exp Primary Sync Reference Unlocked

ExpIO 2xSTM1-PrimarySynchronization Reference Failure Indicator for Expansion IO Card.

N/A N/A INFO

Page 600: Cambium network ptp 810 series 01 00 user guide

PTP 810 MMU Alarms

Alarms‐37

Alarm Affected

Component Description LED to RED Alarm

Code Severity Exp Secondary Sync Reference Unlocked

ExpIO 2xSTM1-SecondarySynchronization Reference Failure Indicator for Expansion IO Card.

N/A N/A INFO

Exp Tertiary Sync Reference Unlocked

ExpIO 2xSTM1-TertiarySynchronization Reference Failure Indicator for Expansion IO Card.

N/A N/A INFO

Unified Modem Fault1 Lower

Modem The specified Lower Modemcard has indicated a security fault. Fault detection is via reading Modem Hardware Status from MODEM during start-up. ‘Lower’ is an indication of the modem card present in the lower position of the MMU chassis.

N/A N/A CRITICAL

Unified Modem Fault1 Upper

Modem The specified Upper Modemcard has indicated a security fault. Fault detection is via reading Modem Hardware Status from MODEM during start-up. ‘Upper’ is an indication of the modem card present in the upper position of the MMU chassis.

N/A N/A CRITICAL

Unified Modem Fault2 Lower

Modem The specified Lower Modemcard has indicated a security fault. Fault detection is via reading Modem Hardware Status from MODEM during start-up. ‘Lower’ is an indication of the modem card present in the lower position of the MMU chassis.

N/A N/A CRITICAL

Page 601: Cambium network ptp 810 series 01 00 user guide

PTP 810 MMU Alarms

Alarms‐38

Alarm Affected

Component Description LED to RED Alarm

Code Severity Unified Modem Fault2 Upper

Modem The specified Upper Modemcard has indicated a security fault. Fault detection is via reading Modem Hardware Status from MODEM during start-up. ‘Upper’ is an indication of the modem card present in the upper position of the MMU chassis.

N/A N/A CRITICAL