Top Banner
Watch Movement Specification and Drawing CALENDAR Cal. VX43E Movement Size Casing Diameter Height Battery Life 11 1/2’’’ Ø 25.6mm 2.98mm 3 years
23

Cal. VX43E - Epson · Equipment to be used SEIKO quartz tester QT-99, Greiner quartz timer-C , Witschi Q-tester 4000 Duration of measurement 10 seconds Microphone to be used Electromagnetic

Aug 02, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Cal. VX43E - Epson · Equipment to be used SEIKO quartz tester QT-99, Greiner quartz timer-C , Witschi Q-tester 4000 Duration of measurement 10 seconds Microphone to be used Electromagnetic

Watch Movement Specification and Drawing

CALENDAR

Cal. VX43E

Movement Size

Casing Diameter

Height

Battery Life

11 1/2’’’

Ø 25.6mm

2.98mm

3 years

Page 2: Cal. VX43E - Epson · Equipment to be used SEIKO quartz tester QT-99, Greiner quartz timer-C , Witschi Q-tester 4000 Duration of measurement 10 seconds Microphone to be used Electromagnetic

Date: 29/Jun./'20

Cal. VX43EItems Rev. Page

Specifications 03 1

Appearance 04 2

Casing 05 3

Hand fitting 05 4

Hand setting stem 04 5

Dial-01 02 6-01

Dial-04 01 6-04

Dial-05 01 6-05

Dial-06 01 6-06

Dial-07 02 6-07

Dial-08 02 6-08

Dial-09 02 6-09

Dial-10 01 6-10

Dial-11 01 6-11

Dial-12 01 6-12

Dial-13 01 6-13

Dial-14 01 6-14

Dial-15 00 6-15

Dial-16 00 6-16

Dial-17 00 6-17

Casing ring 02 7

Page 3: Cal. VX43E - Epson · Equipment to be used SEIKO quartz tester QT-99, Greiner quartz timer-C , Witschi Q-tester 4000 Duration of measurement 10 seconds Microphone to be used Electromagnetic

Date :

1. MOVEMENT DIMENSIONSOutside diameter φ26.40mm × 23.50mm(3-9H) × 23.50mm(12-6H)Casing diameter φ25.60mm × 21.90mm(3-9H) × 23.50mm(12-6H)Total height 2.98mm ( including battery )

2. TIME STANDARDType of quartz oscillator Tuning forkFrequency of quartz oscillator 32,768 HzAccuracy ±20 seconds per month (on wrist)Operating temperature range -5℃ to +50℃Regulation device Nil (Pre-adjusted)

3. INDICATOR / FUNCTIONS3 Hands Hour / Minute / SecondDay / Date Instant setting device for day / date calendarReset switchSetting mechanism Crown at normal position : Free

Crown pulled out 1st click : Instant day / date change Crown pulled out 2nd click : Time setting / Reset

4. FEATURESJewels 0 JewelsAnti-magnetism Over 1600A/m (Direct current magnetic field)Maximum unbalance of hands Hour hand : 0.5μN・m

Minute hand : 0.6μN・mSecond hand : 0.07μN・m

5. BATTERY Type / Size Silver oxide battery /φ9.5mm × t 2.0mmRecommended battery SR920SW (Maxell, Sony, Seizaiken)Nominal voltage 1.55 VBattery life Approx. 3 yearsDriving current consumption Approx. 1.6μAOperation stopping voltage 1.1 V

6. SEPARATED PARTS (Parts code)Hand setting stem 0351177 or 0351578Battery SR920SW

7. TEST OF ACCURACYEquipment to be used SEIKO quartz tester QT-99,

Greiner quartz timer-C , Witschi Q-tester 4000Duration of measurement 10 secondsMicrophone to be used Electromagnetic detection type

All specifications are subject to change without notice.

Cal.

Analog Quartz 11 1/2''' Slim Movement / Three hands (H/M/S) with Day / Date

VX43E Rev. : 03

24/Feb./'14Specifications

P. 1

Page 4: Cal. VX43E - Epson · Equipment to be used SEIKO quartz tester QT-99, Greiner quartz timer-C , Witschi Q-tester 4000 Duration of measurement 10 seconds Microphone to be used Electromagnetic
Page 5: Cal. VX43E - Epson · Equipment to be used SEIKO quartz tester QT-99, Greiner quartz timer-C , Witschi Q-tester 4000 Duration of measurement 10 seconds Microphone to be used Electromagnetic
Page 6: Cal. VX43E - Epson · Equipment to be used SEIKO quartz tester QT-99, Greiner quartz timer-C , Witschi Q-tester 4000 Duration of measurement 10 seconds Microphone to be used Electromagnetic
Page 7: Cal. VX43E - Epson · Equipment to be used SEIKO quartz tester QT-99, Greiner quartz timer-C , Witschi Q-tester 4000 Duration of measurement 10 seconds Microphone to be used Electromagnetic
Page 8: Cal. VX43E - Epson · Equipment to be used SEIKO quartz tester QT-99, Greiner quartz timer-C , Witschi Q-tester 4000 Duration of measurement 10 seconds Microphone to be used Electromagnetic
Page 9: Cal. VX43E - Epson · Equipment to be used SEIKO quartz tester QT-99, Greiner quartz timer-C , Witschi Q-tester 4000 Duration of measurement 10 seconds Microphone to be used Electromagnetic
Page 10: Cal. VX43E - Epson · Equipment to be used SEIKO quartz tester QT-99, Greiner quartz timer-C , Witschi Q-tester 4000 Duration of measurement 10 seconds Microphone to be used Electromagnetic
Page 11: Cal. VX43E - Epson · Equipment to be used SEIKO quartz tester QT-99, Greiner quartz timer-C , Witschi Q-tester 4000 Duration of measurement 10 seconds Microphone to be used Electromagnetic
Page 12: Cal. VX43E - Epson · Equipment to be used SEIKO quartz tester QT-99, Greiner quartz timer-C , Witschi Q-tester 4000 Duration of measurement 10 seconds Microphone to be used Electromagnetic
Page 13: Cal. VX43E - Epson · Equipment to be used SEIKO quartz tester QT-99, Greiner quartz timer-C , Witschi Q-tester 4000 Duration of measurement 10 seconds Microphone to be used Electromagnetic
Page 14: Cal. VX43E - Epson · Equipment to be used SEIKO quartz tester QT-99, Greiner quartz timer-C , Witschi Q-tester 4000 Duration of measurement 10 seconds Microphone to be used Electromagnetic
Page 15: Cal. VX43E - Epson · Equipment to be used SEIKO quartz tester QT-99, Greiner quartz timer-C , Witschi Q-tester 4000 Duration of measurement 10 seconds Microphone to be used Electromagnetic
Page 16: Cal. VX43E - Epson · Equipment to be used SEIKO quartz tester QT-99, Greiner quartz timer-C , Witschi Q-tester 4000 Duration of measurement 10 seconds Microphone to be used Electromagnetic
Page 17: Cal. VX43E - Epson · Equipment to be used SEIKO quartz tester QT-99, Greiner quartz timer-C , Witschi Q-tester 4000 Duration of measurement 10 seconds Microphone to be used Electromagnetic
Page 18: Cal. VX43E - Epson · Equipment to be used SEIKO quartz tester QT-99, Greiner quartz timer-C , Witschi Q-tester 4000 Duration of measurement 10 seconds Microphone to be used Electromagnetic
Page 19: Cal. VX43E - Epson · Equipment to be used SEIKO quartz tester QT-99, Greiner quartz timer-C , Witschi Q-tester 4000 Duration of measurement 10 seconds Microphone to be used Electromagnetic
Page 20: Cal. VX43E - Epson · Equipment to be used SEIKO quartz tester QT-99, Greiner quartz timer-C , Witschi Q-tester 4000 Duration of measurement 10 seconds Microphone to be used Electromagnetic
Page 21: Cal. VX43E - Epson · Equipment to be used SEIKO quartz tester QT-99, Greiner quartz timer-C , Witschi Q-tester 4000 Duration of measurement 10 seconds Microphone to be used Electromagnetic
Page 22: Cal. VX43E - Epson · Equipment to be used SEIKO quartz tester QT-99, Greiner quartz timer-C , Witschi Q-tester 4000 Duration of measurement 10 seconds Microphone to be used Electromagnetic
Page 23: Cal. VX43E - Epson · Equipment to be used SEIKO quartz tester QT-99, Greiner quartz timer-C , Witschi Q-tester 4000 Duration of measurement 10 seconds Microphone to be used Electromagnetic