Top Banner
Cables for alarm- and safety systems Flexible and safe solutions, for decades.
16

Cables for alarm- and safety systems - Nexans · Cables for alarm- and safety systems Flexible and safe solutions, for decades. e offer the widest ... IP67 outlet box offers a safe

Nov 01, 2018

Download

Documents

doanque
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Cables for alarm- and safety systems - Nexans · Cables for alarm- and safety systems Flexible and safe solutions, for decades. e offer the widest ... IP67 outlet box offers a safe

Cables for alarm- and safety systems

Flexible and

safe solutions,

for decades.

Page 2: Cables for alarm- and safety systems - Nexans · Cables for alarm- and safety systems Flexible and safe solutions, for decades. e offer the widest ... IP67 outlet box offers a safe

We offer the widest

range of cables on

the market for every

kind of installation.

2

Page 3: Cables for alarm- and safety systems - Nexans · Cables for alarm- and safety systems Flexible and safe solutions, for decades. e offer the widest ... IP67 outlet box offers a safe

It´s all about reliability.It is always important to choose high quality cables,

especially when it comes to alarms and safety systems.

Even small and seemingly insignificant details can make

a big difference in terms of ease of handling, functiona-

lity and service life.

We have the cables you are looking for

We offer the widest range of cables on the market for

every kind of installation. The cables we supply carry

signals and power supplies. For extra peace of mind

concerning fire protection, our cables are available in

versions meeting specified fire safety requirements in

installations.

Halogen free for greater safety

We have decided only to include halogen free cables

in this brochure. There is a clear trend in that direc-

tion, and there is no longer any reason for not choosing

halogen free cables. Halogen free cables offer many

advantages – in particular, they make it easier to escape

the building in the event of fire, generating substantial

savings in the long run.

100 years of experience thrown in

At Nexans we research, develop and manufacture cables

for the whole world. For different environments and cli-

mates. And we’ve been doing it for more than a hundred

years. So when you choose our cables, they come with a

whole lot more – our dedication and all the experience

and expertise we’ve built up over the decades.

3

Page 4: Cables for alarm- and safety systems - Nexans · Cables for alarm- and safety systems Flexible and safe solutions, for decades. e offer the widest ... IP67 outlet box offers a safe

Product segments

Fire alarms Detector networks often occupy

large volumes so cables must be

easy to install. Nexans cables are

easy to strip and are optimised

to simplify installation in pipes.

Choose from simple, non twisted

pair cables for small conventional

systems and twisted pair cables for

larger addressable systems. The

cables used in fire alarm detector

networks should normally have a

red sheath. If the cables are requi-

red to keep working during a fire,

you should use Nexans Alsecure®

(see page 12 ”Performance during

a fire”).

Video surveillance (CCTV) Locally installed CCTV (closed circuit

TV) systems are increasingly being

used as a crime prevention tool.

4

Page 5: Cables for alarm- and safety systems - Nexans · Cables for alarm- and safety systems Flexible and safe solutions, for decades. e offer the widest ... IP67 outlet box offers a safe

Access protection Burglar alarms usually have a

system of control units and sensors.

Indoor and outdoor entry systems

contain card readers, central units

and computers. The cables used

for intruder protection and entry

control are signal cables with vary-

ing flexibility, shielding and cores.

Alternatively, combination cables

can be used with separate cores

carrying the power supply.

Nexans’ wide range makes it easy

to choose the right cables for the

various components.

Performance during a fireThere is a separate fire class for

cables that are required to maintain

sircuit integrity during a fire. These

cables all have unique insulation

material that is not damaged like

normal cables. This category can

include power supply cables as well

as signal cables. They should also

be flame retardant low fire hazard

cables – in other words they must

not give off any toxic or corrosive

gases, and only small amounts of

smoke, if there is a fire.

The Nexans cables for these appli-

cations are called Alsecure®. The

unique insulation (INFIT™) makes the

cables easy to install while ensuring

they still work during a fire.

5

Page 6: Cables for alarm- and safety systems - Nexans · Cables for alarm- and safety systems Flexible and safe solutions, for decades. e offer the widest ... IP67 outlet box offers a safe

CCTV (Closed Circuit TeleVision) is a locally installed

video surveillance system. A CCTV system consists of

cameras, monitors, transmission elements (cables),

control systems and storage systems. Our range of

halogen free cables for CCTV includes 75 ohm coaxial

cable.

The S/FTP Category 6A cable together with the

IP67 outlet box offers a safe and robust solution for

solutions for IP network cameras outdoor and in harsh

environments.

For added safety, vi-deo surveillance cables are also flame retar-dant and halogen free.

RG 59 LSZHCoaxial cable for video surveillance. The impedance of the

cable: 75 ohm.

Cable Nexans no. Outer diam. Length

RG 59 LSZH 19502641 6,1 mm Bobbin/100

RG 59 LSZH 19502671 6,1 mm Bobbin/500

Video surveillance (CCTV)

6

Page 7: Cables for alarm- and safety systems - Nexans · Cables for alarm- and safety systems Flexible and safe solutions, for decades. e offer the widest ... IP67 outlet box offers a safe

LANmark Industry outlet IP67The LANmark Industry outlet enables the installation of data

outlets in exposed areas as well as outdoor solutions. The IP67

level of protection is maintained both when the outlet is unused

and when the appropriate IP67 patchcords are connected.

Includes 2 screened category 6 or category 6A connectors.Cable Nexans no.

IP67 outer with RJ45 cat.6 shielded Snap-in connector, black. 40060109

IP67 outer with RJ45 cat.6A shielded Snap-in connector, black. 40061009

S/FTP Category 6A LSZH + PECategory 6A, 500 MHz Screened data cable. The 4 pairs are

individually foiled and covered with a common braid. Due to

the outer sheath of PE the cable is appropriate for outdoor

installation as well as in exposed areas. It can be installed indo-

ors when the PE sheet is removed. The cable fulfills cat 6A per-

formance according to EN 50288, IEC 61156 and TIA 568-B

Cable Nexans no. Outer diam. Length

Category 6A 4x2x0,5 39020771 8,6 mm B/500

7

Page 8: Cables for alarm- and safety systems - Nexans · Cables for alarm- and safety systems Flexible and safe solutions, for decades. e offer the widest ... IP67 outlet box offers a safe

Find out more about fire safety and fire classes.

8

Page 9: Cables for alarm- and safety systems - Nexans · Cables for alarm- and safety systems Flexible and safe solutions, for decades. e offer the widest ... IP67 outlet box offers a safe

You often won’t know whether you chose the right cable until after a fire.People always talk about fire protection but it is important to know what this actually

means in practical terms, and to be certain which flame spread rating you need to use.

For cables, you also need to distinguish between flame spread, fire hazard properties and

fire resistance.

Cables that prevent flame spread

Cables running through building levels and walls are a great way for fires to spread. So

the most important requirement when establishing fire protection is to use cables with

properties that prevent the spread of fire. This is why there are general flame spread

classes, and these must always be defined. Our cables have clearly marked flame spread

classes that are informative and easy to understand.

Halogen free – saving lives and money

Smoke and gases from burning cables often cause the biggest problems for people and

equipment. These problems can be reduced if halogen free cables are used. The smoke

from halogen free cables during a fire is much thinner and does not corrode metals.

This makes it easier to clear smoke from rooms, potentially saving lives. That is why our

cables for alarms and safety systems are halogen free.

Still working during a fire

The most critical cables must also be fire resistant. This means they must be guaranteed

to work even during a fire. This is made possible by special insulation material, which is

merely altered rather than destroyed by fire. The cable keeps its shape, the conductors

are kept separate and the cable continues to work. These cables are needed for the fire

alarm system itself, but also for the safety lighting guiding people out of the building, for

the smoke extraction fans and for the lifts. Our range includes fire resistant cables for

power supply and for communication.

9

Page 10: Cables for alarm- and safety systems - Nexans · Cables for alarm- and safety systems Flexible and safe solutions, for decades. e offer the widest ... IP67 outlet box offers a safe

Nexans has a full range of cables for fire alarm systems

The right cable for the right use

Cables for fire alarms are available with either red or grey

sheaths depending on the regulations, aesthetic requi-

rements, etc. In larger addressable systems, twisted pair

cable should be used, KLM-LSZH 2x1.0 mm. If shielded

cable is required, Nexans supplies the KLMA LSZH. If the

cables are required to keep working during a fire, fire

resistant Alsecure cables are used.

Installation

The cables for fire alarms are intended for permanent

indoor installation.

ELQRBSignal cable for fire alarms. ELQRB construction is as specified

in SS 424 16 09.

Cable Nexans no. Outer diam. Length

ELQRB 2 x 0,6 mm 18641541 2,9 x 4,2 mm Bobbin/100

ELQRB 2 x 0,6 mm 18641571 2,9 x 4,2 mm Bobbin/500

ELQRB 2 x 1,0 mm 18641641 3,3 x 4,9 mm Bobbin/100

ELQRB 2 x 1,0 mm 18641671 3,3 x 4,9 mm Bobbin/500

ELQRB 4 x 1,0 mm 18641971 5,7 mm Bobbin/500

KLM LSZH 2x1,0Halogen free, pair-twisted signal cable. The cable construction

is as specified in SS 424 16 54 (ELQYB).Cable Nexans no. Outer diam. Length

KLM LSZH 2x1,0 37159271 5,7 mm Bobbin/500

Fire alarms

KLMA LSZH Halogen free, pair-twisted signal cable. The cable construction

is as specified in SS 424 16 54 (ELQYB).Cable Nexans no. Outer diam. Length

KLMA LSZH 2x0,8 37158243 5,0 mm Coil/150

KLMA LSZH 2x0,8 37158258 5,0 mm Bobbin/600

KLMA LSZH 4x0,8 37158443 5,5 mm Coil/150

KLMA LSZH 4x0,8 37158458 5,5 mm Bobbin/600

KLM LSZH Halogen free signal cable. The cable construction is, where

applicable, as specified in SFS 2751.Cable Nexans no. Outer diam. Length

KLM LSZH 2x0,8 37156243 4,0 mm Coil/150

KLM LSZH 2x0,8 37156258 4,0 mm Bobbin/600

KLM LSZH 4x0,8 37156443 5,0 mm Coil/150

KLM LSZH 4x0,8 37156458 5,0 mm Bobbin/600

10

Page 11: Cables for alarm- and safety systems - Nexans · Cables for alarm- and safety systems Flexible and safe solutions, for decades. e offer the widest ... IP67 outlet box offers a safe

Fire resistant cables maintain circuit integrity even when affected by heat or flames.

11

Page 12: Cables for alarm- and safety systems - Nexans · Cables for alarm- and safety systems Flexible and safe solutions, for decades. e offer the widest ... IP67 outlet box offers a safe

Fire resistant cables are recommended for use in instal-

lations that must maintain circuit integrity during a fire.

Using these cables in important alarm, control, signal and

power supply systems means you can guarantee they will

not be taken down, even if the fire reaches the cables

themselves.

No gases, little smoke

As well as continuing to work during and after a fire,

Nexans fire resistant cables are halogen free so they do

not release any toxic or corrosive gases, and only small

amounts of smoke, if there is a fire. Studies show that this

can save lives and money.

Installation

Examples of systems that must maintain circuit integrity

during a fire include signal and safety systems guiding

people out of the building. Other examples are smoke

extraction fans and lifts. Fire alarm cables, too, if they

pass through areas that are not monitored by detectors,

are required to maintain circuit integrity during a fire.

ALSECURE® PLUS TEL, screenedFire resistant, twisted pair, shielded telecom and signal cables

for permanent installation indoors or in pipes. Fire performance

according to IEC60331, IEC 60332-3.Cable Nexans

no.Outer diam.

Length

Alsecure Plus Tel 1 x 2 x 0,9 mm 17541198 6,7 mm Drum/500

Alsecure Plus Tel 2 x 2 x 0,9 mm 17541298 7,4 mm Drum/500

Alsecure Plus Tel 10 x 2 x 0,9 mm 17541698 16,0 mm Drum/500

ALSECURE® PREMIUMFire resistant, twisted pair, fire alarm cables for permanent

installation indoors or in pipes. Fire performance according to

IEC60331, IEC 60332-3. Cable Nexans

no.Outer diam.

Length

Alsecure Premium 2 x 1,0 mm 17542171 6,2 mm Bobbin/500

Alsecure Premium 10 x 2 x 1,0 mm 17542698 17,0 mm Drum/500

ALSECURE® PLUS 0,6/1kV, FRHFFire resistant power cable with round or sector shaped, stranded,

soldered copper conductor and concentric shielding. For perma-

nent installation in all areas. Fire performance according to IEC

60331, IEC 60332-3.Cable Nexans no. Outer diam. Length

Alsecure Plus 1kV 2 x 1,5/1,5 27005698 11,9 mm Drum/500

Alsecure Plus 1kV 3 x 1,5/1,5 27004498 12,5 mm Drum/500

Alsecure Plus 1kV 4 x 1,5/1,5 27005798 15,2 mm Drum/500

Alsecure Plus 1kV 2 x 2,5/2,5 27005898 14,7 mm Drum/500

Alsecure Plus 1kV 3 x 2,5/2,5 27005998 15,2 mm Drum/500

Alsecure Plus 1kV 4 x 2,5/2,5 27030198 16,4 mm Drum/500

Alsecure Plus 1kV 4 x 6/6 35123998 18,1 mm Drum/500

Alsecure Plus 1kV 4 x 10/10 35124198 22,0 mm Drum/500

Alsecure Plus 1kV 4 x 16/16 35124398 24,2 mm Drum/500

Alsecure Plus 1kV 4 x 25/16 35124598 26,0 mm Drum/500

Alsecure Plus 1kV 4 x 35/16 35124798 30,0 mm Drum/500

Alsecure Plus 1kV 4 x 50/25 35126598 35,0 mm Drum/500

Alsecure Plus 1kV 4 x 70/35 35125198 36,0 mm Drum/500

Alsecure Plus 1kV 4 x 95/50 35125398 41,0 mm Drum/500

Alsecure Plus 1kV 4 x 120/70 35125598 42,2 mm Drum/500

Alsecure Plus 1kV 4 x 150/70 35125798 49,0 mm Drum/500

Alsecure Plus 1kV 4 x 185/95 35125898 52,0 mm Drum/500

Alsecure Plus 1kV 4 x 240/120 35126198 60,0 mm Drum/500

Performance during a fire

12

Page 13: Cables for alarm- and safety systems - Nexans · Cables for alarm- and safety systems Flexible and safe solutions, for decades. e offer the widest ... IP67 outlet box offers a safe

Another important fire safety property is low smoke development.

ALSECURE® PREMIUM 300/500VFire resistant, halogen free control cables with round, solid

copper conductors. This cable is designed for permanent instal-

lation on cable ladders, directly on walls or in pipes or ducting.

Applications include emergency lighting, fire alarm systems and

control systems. Fire performance according to IEC60331, IEC

60332-3.Cable Nexans no. Outer diam. Length

Alsecure Premium 3G1,5 27010098 8,0 mm Drum/500

Alsecure Premium 3G2,5 27010198 10,0 mm Drum/500

Alsecure Premium 4G1,5 27010298 9,5 mm Drum/500

Alsecure Premium 5G1,5 27010398 10,0 mm Drum/500

Alsecure Premium 5G2,5 27010598 12,0 mm Drum/500

ALSECURE® PLUS STYR 300/500VFire resistant, halogen free, unshielded installation cables with

round, solid copper conductors. For permanent installation

on cable ladders, directly on walls or in pipes or ducting. Fire

performance according to IEC60331, IEC 60332-3.

Cable Nesans no. Outer diam. Length

Alsecure Plus Styr 7G1,5 27001498 14,0 mm Drum/500

Alsecure Plus Styr 12G1,5 27001198 19,5 mm Drum/500

Alsecure Plus Styr 19G1,5 27004198 22,5 mm Drum/500

Alsecure Plus Styr 7G2,5 27008298 16,0 mm Drum/500

13

Page 14: Cables for alarm- and safety systems - Nexans · Cables for alarm- and safety systems Flexible and safe solutions, for decades. e offer the widest ... IP67 outlet box offers a safe

Access protectionOur cables for intruder alarms and entry systems come in

a range of types. We have shielded as well as unshielded

twisted pair cables – up to ten pairs. We also offer flexible

single wire cables with 4 to 12 cores. Combination cables

are also available for entry systems – cables with twisted

pair signal elements and power supply elements (max 100

V).

MHS LSZHPair-twisted, shielded communication cable with halogen free,

flame retardant sheath. The cable construction is, where appli-

cable, as specified in SFS 5739.

Cable Nexans no. Outer diam. Length

MHS LSZH 1x4x0,5 38565040 5,0 Coil/100

MHS LSZH 1x4x0,5 38565098 5,0 Drum/1000

MHS LSZH 3x2x0,5 38565145 6,0 Coil/200

MHS LSZH 3x2x0,5 38565198 6,0 Drum/1000

MHS LSZH 5x2x0,5 38565243 6,5 Coil/150

MHS LSZH 5x2x0,5 38565298 6,5 Drum/1000

MHS LSZH 10x2x0,5 38565340 8,5 Coil/100

MHS LSZH 10x2x0,5 38565398 8,5 Drum/1000

EQQXB Easy TM (halogen free EKKX)Pair-twisted communication cable with halogen free, flame retar-

dant insulation and sheath. An important feature of the cable is

that both insulation and sheath are easy to peel. You can even

peel the insulation with your nail. Fire performance according to

IEC 60332-1.

Cable Nexans no.

Outer diam.

Length

EQQXB Easy TM 1 x 4 x 0,5 mm 17116041 3,5 mm Bobbin/100

EQQXB Easy TM 1 x 4 x 0,5 mm 17116071 3,5 mm Bobbin/500

EQQXB Easy TM 2 x 2 x 0,5 mm 17116141 4,3 mm Bobbin/100

EQQXB Easy TM 2 x 2 x 0,5 mm 17116171 4,3 mm Bobbin/500

EQQXB Easy TM 4 x 2 x 0,5 mm 17116341 5,5 mm Bobbin/100

EQQXB Easy TM 4 x 2 x 0,5 mm 17116371 5,5 mm Bobbin/500

EQQXB Easy TM 6 x 2 x 0,5 mm 17116441 6,0 mm Bobbin/100

EQQXB Easy TM 6 x 2 x 0,5 mm 17116471 6,0 mm Bobbin/500

EQQXB Easy TM 10 x 2 x 0,5 mm 17116641 7,3 mm Bobbin/100

EQQXB Easy TM 10 x 2 x 0,5 mm 17116671 7,3 mm Bobbin/500

FQQXBFlexible signal and alarm cables for intruder alarms and access

control systems. Cable Nexans no. Outer diam. Length

FQQXB 4 x 0,22 mm2 17523141 3,7 mm Bobbin/100

FQQXB 4 x 0,22 mm2 17523171 3,7 mm Bobbin/500

FQQXB 6 x 0,22 mm2 17523241 4,2 mm Bobbin/100

FQQXB 6 x 0,22 mm2 17523271 4,2 mm Bobbin/500

FQQXB 8 x 0,22 mm2 17523341 4,7 mm Bobbin/100

FQQXB 8 x 0,22 mm2 17523371 4,7 mm Bobbin/500

FQQXB 12 x 0,22 mm2 17523441 5,4 mm Bobbin/100

FQQXB 12 x 0,22 mm2 17523471 5,4 mm Bobbin/500

FQQXB 4 x 2 x 0,22 mm2 17524271 5,3 mm Bobbin/500

FQQXB 10 x 2 x 0,22 mm2 17524898 8,0 mm Drum/500

14

Page 15: Cables for alarm- and safety systems - Nexans · Cables for alarm- and safety systems Flexible and safe solutions, for decades. e offer the widest ... IP67 outlet box offers a safe

FLAQQBRCombined power supply and signal cables for intruder alarms

and entry systems. The twisted pair signal element is unshielded.Cable Nexans

no.Outer diam.

Length

FLAQQBR 2 x 1,0 + 1 x 2 x 0,22 mm2 17033341 6,5 mm Bobbin/100

FLAQQBR 2 x 1,0 + 1 x 2 x 0,22 mm2 17033371 6,5 mm Bobbin/500

FLAQQBR 2 x 1,0 + 2 x 2 x 0,22 mm2 17515198 8,0 mm Drum/500

FLAQQBR 3 x 1,0 + 2 x 2 x 0,6 mm 17034298 8,5 mm Drum/500

FLQQBRCombined power supply and signal cables for intruder alarms

and entry systems. The twisted pair signal element is unshielded.Cable Nexans

no.Outer diam.

Length

FLQQBR 2 x 1,5 + 2 x 2 x 0,5 mm2 17513198 8,5 mm Drum/500

FLQQBR 2 x 1,0 + 1 x 2 x 0,22 mm2 17513041 6,5 mm Bobbin/100

FLQQBR 2 x 1,0 + 1 x 2 x 0,22 mm2 17513071 6,5 mm Bobbin/500

FLQQBR 2 x 1,0 + 2 x 2 x 0,22 mm2 17513271 7,5 mm Bobbin/500

We have the exact

cable that complies

to all your needs.

FLAQQLYCombined power supply and signal cable for intruder alarms

and entry systems. The pairs for signalling have a common

screen of aluminium/polyesterfoil.

The cable has a protective PE sheath covering the inner sheat of

halogen free flame retardant plastic compound and is intended

for fixed installations both indoor and outdoor.

Cabel Nexans no.

Outer diam.

Length

FLAQQLY 2 x 1,0 + 2 x 2 x 0,22 mm2 17039298 9,0 mm Drum/500

15