Top Banner
Bulk Cable / Custom Cable Assemblies / Cable Management Products /Small Panel Assembly Get it Started and Stay Connected. CABLE GUIDE
57

Cable Guide

Nov 28, 2015

Download

Documents

vinaybaba

hfhc
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Cable Guide

Bulk Cable / Custom Cable Assemblies / Cable Management Products /Small Panel Assembly

Get it Started and Stay Connected.

CABLE GUIDE

Page 2: Cable Guide

Contents COMPANY OVERVIEW ............................................................................................................................... 4

CONTACT INFORMATION .......................................................................................................................... 7

8 AWG Cable Specifications....................................................................................................................... 8

8 AWG / 4C ............................................................................................................................................ 9

10 AWG Cable Specifications .................................................................................................................. 10

10 AWG / 3C ........................................................................................................................................ 11

10 AWG / 4C ........................................................................................................................................ 12

10 AWG / 6C ........................................................................................................................................ 13

12 AWG Cable Specifications .................................................................................................................. 14

12 AWG / 3C ........................................................................................................................................ 15

12 AWG / 4C ........................................................................................................................................ 16

12 AWG / 4C ........................................................................................................................................ 17

12 AWG / 7C ........................................................................................................................................ 18

14 AWG Cable Specifications .................................................................................................................. 19

14 AWG / 3C ........................................................................................................................................ 20

14 AWG / 3C ........................................................................................................................................ 21

14 AWG / 4C ........................................................................................................................................ 22

14 AWG / 4C ........................................................................................................................................ 23

14 AWG / 5C ........................................................................................................................................ 24

14 AWG / 7C ........................................................................................................................................ 25

16 AWG Cable Specifications .................................................................................................................. 26

16 AWG / 3C ........................................................................................................................................ 27

16 AWG / 3C ........................................................................................................................................ 28

16 AWG / 4C ........................................................................................................................................ 29

16 AWG / 4C ........................................................................................................................................ 30

16 AWG / 7C ........................................................................................................................................ 31

16 AWG / 7C ........................................................................................................................................ 32

16 AWG / 7C ........................................................................................................................................ 33

16 AWG / 7C ........................................................................................................................................ 34

16 AWG / 12C ...................................................................................................................................... 35

16 AWG / 12C ...................................................................................................................................... 36

Page 3: Cable Guide

16 AWG / 12C ...................................................................................................................................... 37

16 AWG / 18C ...................................................................................................................................... 38

16 AWG / 19C ...................................................................................................................................... 39

16 AWG / 25C ...................................................................................................................................... 40

16 AWG / 25C ...................................................................................................................................... 41

16 AWG / 33C ...................................................................................................................................... 42

16 AWG / 37C ...................................................................................................................................... 43

22 AWG Cable Specifications .................................................................................................................. 44

22 AWG / 24C ...................................................................................................................................... 45

Communication / Shielded Cable Specifications ..................................................................................... 46

20 AWG / 3C ........................................................................................................................................ 47

20 AWG / 2 PR ..................................................................................................................................... 48

20 AWG / 3 PR ..................................................................................................................................... 49

20 AWG / 16 PR ................................................................................................................................... 50

22 AWG / 3 PR ..................................................................................................................................... 51

22 AWG / 3 PR ..................................................................................................................................... 52

22 AWG / 17 PR ................................................................................................................................... 53

22 AWG / 37 PR ................................................................................................................................... 54

Hybrid / Composite Cable Specifications ................................................................................................ 55

16AWG/1PR 22AWG/3PR .................................................................................................................... 56

14AWG/4C | 18AWG/2PR ................................................................................................................... 56

Page 4: Cable Guide

COMPANY OVERVIEW

Get Started with Electrivert. Automation equipment doesn’t run by itself. It needs power. Electrivert helps deliver that power with top quality, NFPA-79 certified, control and power cables – customized for your specific applications.

As a leading manufacturer and full-service provider of molded and custom cable assemblies, Electrivert works with companies across the U.S. – meeting and exceeding their interconnect needs for industrial machinery and factory automation.

Flexible and Fast Electrivert has built a “reputation of excellence” by adhering to a simple philosophy…we listen. We work with you to match a solution to your requirements. Whether it’s a planned application or last minute request, we’re flexible and fast enough to get it done on time and on budget. And, our in-house engineering and testing teams ensure that all products meet and exceed industry standards – as well as your expectations. That’s why we’re the preferred supplier for top quality custom cable assemblies.

Our Mission – To be the Best! At Electrivert, our goal is to be your best source for custom cable assemblies:

• Outstanding service and support • Engineering expertise in design innovations • Manufacturing capabilities that offer mechanical and molded assemblies • A Flexible work force to service you more effectively and efficiently • Approved as a government build source (U.S. Government CAGE CODE 08 NE8) • ISO 9002 registered • Free local shipping • Made in the USA Every product is 100% tested and defect free.

Page 5: Cable Guide

Electrivert PERFORMANCE PLUS™ Molded Industrial Cables

Electrivert’s PERFORMANCE PLUS™ molded cable assemblies are available as both straight and 90° configurations and are rated to IP65 and NEMA 12 when mated to DIN 43652 receptacles. And, our diecast shells use ElectriLatch™, instead of pins, which makes it more resistant to shock and vibration. Nickel-plating offers increased conductivity, improved corrosion resistance and better appearance.

PERFORMANCE PLUS™ molded cable assemblies are also engineered to comply with and meet GM NCCC-3 specifications for automotive control cables.

Features and Benefits:

• Two-stage molding process ensures a high quality product that reduces downtime and maintenance costs, improves process quality and reduces installation times

• Tamper-proof to ensure the reliability and uptime of any installation • Designed to eliminate conductor stress and contact push back to help reduce system failures • 250 lbs pull out force ratings improve system reliability and eliminate intermittent connection issues • Omni-directional flex strain relief reduces installation and maintenance issues • Overmolding process ensures reliable connections in harsh environments, including IP65 • Rugged design decreases downtime and maintenance costs related to damaged hoods or latch pins • Availability in standard and custom lengths to facilitate your design process and reduce

procurement costs • Fewer components to provide quick turnaround and delivery times • Availability in Flex or Static/Tray for total design flexibility • Made in Michigan, supporting local manufacturing

Get it Started and Stay Connected.

Custom Cable Assemblies

Page 6: Cable Guide

DISTRIBUTION PRODUCTS

Electrivert is also a leading distributor for Harting rectangular connectors, Remke mini and micro machine tool cords and Mohawk/Alpha custom cable. This distribution rela- tionship allows us to give our customers faster turnaround time for either kits or custom built assemblies.

Harting Han® Industrial Cable Assemblies

These multi-pin connectors utilize robust metal hoods and housings for protection from dust, liquids and physical damage.

• UL and CSA approved • NEMA Type 4/12 Rating • Flexible conduit and jacketed cable • IP 68 protection available • Power and signal combinations

Remke Tuff-Seal™ Wire Management Products Remke’s wire management products include strain relief cord connectors in a variety of sizes and styles, wire mesh grips, corrosion-resistant and liquid-tight connectors. The rugged cord grips, conduit adapters and basketweaves protect cable from damage and environmental concerns.

• Can be customized to fit your specific needs • Your choice of NPT, Pg or Metric threads. • Meet UL and CSA specifications for keeping out oil, water, dirt and other contaminants.

Remke Tuff-Link™ Molded Connectors and Cordsets Remke’s full-line of mini, micro (M12) and pico (M8) tool cords are manufactured to indus- try standards along with various splitters, distribution boxes and accessories. They are used as the interconnect for sensors, actuators and other control devices in automated manufacturing and production equipment.

• Can be customized to fit your specific needs

Mohawk/Alpha Cable Products Mohawk’s cables meet all of your factory automation applications – from power to control to communication. We can work with you to develop and engineer a cable to meet your specific needs.

• All 600V cables are manufactured to meet NFPA-79 specifications. • Meets and supports TIA/EIA, ISO/IEC, ICEA and NEMA standards.

Contact us today, toll-free, at 877-768-5535 or email us at [email protected] to discover how we can help you get it started and stay connected.

Custom Cable Assemblies

17850 14 Mile Road Fraser, MI 48026-2271 877-768-5535 Toll-Free Phone: 586-285-0720 Fax: 586-285-0742 [email protected] www.electrivert.com

Made with Pride in the USA

Page 7: Cable Guide

CONTACT INFORMATION

Mailing Address: 17850 14 Mile Road Fraser, MI 48026-2271

Toll Free: (877) 768-5535 Local Telephone: (586) 285-0720 Fax: (586) 285-0742

General E-mail: [email protected]

Website: www.electrivert.com

Sales: Ken Murphy – (586) 764-5874

Jody Williquette – (586) 489-1818

Customer Service & Estimating

Terri Berliner – (586) 285-0720 x 131 Gary Ellingham – (586) 285-0720 x 135

Production and Mfg: Bonny Letlow – (586) 285-0720 x 127

Page 8: Cable Guide

8 AWG Cable Specifications

Page 9: Cable Guide

INSULATION: .032” (.81 mm) OF 105°C PVC

TEMP. RANGE: -25°C TO +105°C NOMINAL DIAMETER: .251” (6.37 mm)

APPLICATIONS 9.0” LEFT HAND LAY

25% OVERLAP • ROBOTICS AND PLANT AUTOMATION EQUIPMENT

TRAYS - EXPOSED RUNS LISTINGS: CSA AWM I/II A/B FT4 - 90°C, 600V

Cabling Excellence for Open Architecture

Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations.

SPECIFICATION 4 CONDUCTOR HEAVY DUTY

POWER SUPPLY CABLE

K40185 8 AWG / 4C

Jacket

Insulation

Conductor

Barrier

CONSTRUCTION PHYSICAL CHARACTERISTICS

PRIMARIES: COND: 8 AWG (8.60 mm²) (168/30) BARE CABLE WEIGHT: 390 lbs/1000ft (573 kg/km) COPPER BENDING RADIUS: 7.4” (188 mm) MIN (10 x CABLE OD)

SHEATH: .0055” (.14 mm) OF NYLON RECOMMENDED

CABLE ASSEMBLY: 4 CONDUCTORS CABLED WITH FILLERS IN A

BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING

JACKET: ORANGE THERMOPLASTIC ELASTOMER • MACHINE TOOLS

NOMINAL OD: .740” (18.80 mm) • MATERIAL HANDLING EQUIPMENT

RATINGS/ UL TYPE TC-ER - 90°C, 600V • TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE

CE / LOW VOLTAGE DIRECTIVE CONDUCTOR COLOR CODE CONDUCTOR #1-#3: BLACK W/WHITE NUMBER PRINTING CONDUCTOR #4: GREEN W/YELLOW STRIPE

PRINT LEGEND: MOHAWK E163873 M58150 8 AWG (8.60 mm sq) 4 COND - UL 1277 TC-ER - 600V THHN (UL) --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40185 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE)

MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA

(978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com

This document is the property of Mohawk. The information contained herein is considered proprietary and not to be

reproduced by any means without written consent of Mohawk.

Rev Description Date Init. A ADD M#, K# , OPEN WIRING; CHANGE TEMP RANGE 02/26/02 WL

B ADD mm sq TO PRINT 06/03/03 VB C UPDATE HEADER/FOOTER, LISTINGS, PRINT 02/03/05 JS D CHG TEMPS, PRINT, APPLICATIONS; ADDED ROHS 11/07/07 VB

Date: 07/03/01 Page 1 of 1

Part Number:

M58150 Orig: Review:

Page 10: Cable Guide

10 AWG Cable Specifications

Page 11: Cable Guide

SHEATH: .005” (.13 mm) OF NYLON

TEMP. RANGE: -25°C TO +90°C CABLE

APPLICATIONS

• MACHINE TOOLS NOMINAL WALL: .052" (1.32 mm)

TRAYS - EXPOSED RUNS RATINGS: CSA AWM I/II A/B FT4 - 90°C, 600V

ELECTRICAL CHARACTERISTICS CONDUCTOR #2: WHITE W/YELLOW STRIPE

CONDUCTOR DCR: .33 Ω/100m (1.02 Ω/Mft) MAX

Cabling Excellence for Open Architecture

Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations.

SPECIFICATION 3 CONDUCTOR HEAVY DUTY

POWER SUPPLY CABLE

K40194 10 AWG / 3C

Jacket

Insulation

Conductor

Barrier

CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 10 AWG (5.32 mm2) (105/30) BARE COPPER CABLE WEIGHT: 180 lbs/1000ft (268 kg/km)

INSULATION: .022” (.56 mm) OF 105°C PVC BENDING RADIUS: 4.9” (124 mm) MIN (10 x CABLE OD)

NOMINAL DIAMETER: .172” (4.37 mm) RECOMMENDED

ASSEMBLY: 3 CONDUCTORS CABLED TOGETHER IN A 4.75” LEFT HAND LAY

BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, 25% OVERLAP • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING

JACKET: GRAY THERMOPLASTIC ELASTOMER • ROBOTICS AND PLANT AUTOMATION EQUIPMENT

NOMINAL OD: .494” (12.55 mm) • MATERIAL HANDLING EQUIPMENT

LISTINGS/ UL TYPE TC-ER - 90°C, 600V • TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE

CE - LOW VOLTAGE DIRECTIVE CONDUCTOR COLOR CODE CONDUCTOR #1: RED W/YELLOW STRIPE

CONDUCTOR #3: GREEN W/YELLOW STRIPE

PRINT LEGEND: MOHAWK E163873 M 10 AWG (5.32 mm sq) 3 COND - UL 1277 TC-ER - 600V THHN (UL) --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40194 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE)

MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA

(978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com

This document is the property of Mohawk. The information contained herein is considered proprietary and not to be

reproduced by any means without written consent of Mohawk.

Rev Description Date Init.

Date: 05/14/08 Page 1 of 1

Part Number:

- Orig: Review:

Page 12: Cable Guide

SHEATH: .005” (.13 mm) OF NYLON

TEMP. RANGE: -25°C TO +90°C CABLE

APPLICATIONS

• MACHINE TOOLS NOMINAL OD: .559” (14.20 mm)

• STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING RATINGS: CSA AWM I/II A/B FT4 - 90°C, 600V

TRAYS - EXPOSED RUNS

CONDUCTOR DCR: .33 Ω/100m (1.02 Ω/Mft) MAX CONDUCTOR #4: GREEN W/YELLOW STRIPE

Cabling Excellence for Open Architecture

Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations.

SPECIFICATION 4 CONDUCTOR HEAVY DUTY

POWER SUPPLY CABLE

K40178 10 AWG / 4C

Jacket

Insulation

Conductor

Barrier

CONSTRUCTION PHYSICAL CHARACTERISTICS

PRIMARIES: COND: 10 AWG (5.31 mm²) (105/30) BARE COPPER CABLE WEIGHT: 252 lbs/1000ft (375 kg/km) INSULATION: .022” (.56 mm) OF 105°C PVC BENDING RADIUS: 5.6” (142 mm) MIN (10 x CABLE OD)

NOMINAL DIAMETER: .172” (4.37 mm) RECOMMENDED

ASSEMBLY: 4 CONDUCTORS CABLED WITH FILLERS IN A 5.5” LEFT HAND LAY

BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, 25% OVERLAP • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING

JACKET: ORANGE THERMOPLASTIC ELASTOMER • ROBOTICS AND PLANT AUTOMATION EQUIPMENT

LISTINGS/ UL TYPE TC-ER - 90°C, 600V • MATERIAL HANDLING EQUIPMENT

CE / LOW VOLTAGE DIRECTIVE • TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE

ELECTRICAL CHARACTERISTICS CONDUCTOR COLOR CODE CONDUCTOR #1-#3: BLACK W/WHITE NUMBER PRINTING

PRINT LEGEND: MOHAWK E163873 M58099 - 10 AWG (5.31 mm sq) 4 COND UL 1277 TC-ER - 600V THHN (UL) --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40178 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE)

MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA

(978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com

This document is the property of Mohawk. The information contained herein is considered proprietary and not to be

reproduced by any means without written consent of Mohawk.

Rev Description Date Init. D UPDATE HEADER/FOOTER, LISTINGS, PRINT 02/03/05 JS

E ADDED ROHS INFOR AND MODIFIED TEMP RATING 06/27/07 VB F UPDATE HDR, BEND RADIUS, APPLICATIONS 07/20/07 BA G CHG RECOMMENDED TEMP RANGE TO 90°C 08/03/07 BA

Date: 04/27/01 Page 1 of 1

Part Number:

M58099 Orig: Review:

Page 13: Cable Guide

SHEATH: .005” (.13 mm) OF NYLON

TEMP. RANGE: -25°C TO +90°C CABLE

APPLICATIONS

• MACHINE TOOLS NOMINAL OD: .660” (16.76 mm)

• STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING RATINGS: CSA AWM I/II A/B FT4 - 90°C, 600V

TRAYS - EXPOSED RUNS

CONDUCTOR DCR: .33 Ω/100m (1.02 Ω/Mft) MAX CONDUCTOR #2: BLUE W/WHITE STRIPE

Cabling Excellence for Open Architecture

Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations.

SPECIFICATION 6 CONDUCTOR HEAVY DUTY

POWER SUPPLY CABLE

K40237 10 AWG / 6C

JACKET

CONDUCTOR INSULATION

BARRIER TAPE

CONSTRUCTION PHYSICAL CHARACTERISTICS

PRIMARIES: COND: 10 AWG (5.31 mm²) (105/30) BARE COPPER CABLE WEIGHT: 358 lbs/1000ft (533 kg/km) INSULATION: .022” (.56 mm) OF 105°C PVC BENDING RADIUS: 6.6” (168 mm) MIN (10 x CABLE OD)

NOMINAL DIAMETER: .172” (4.37 mm) RECOMMENDED

ASSEMBLY: 6 CONDUCTORS CABLED AROUND A FILLER IN A 6.75” LEFT HAND LAY

BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, 25% OVERLAP • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING

JACKET: GRAY THERMOPLASTIC ELASTOMER • ROBOTICS AND PLANT AUTOMATION EQUIPMENT

LISTINGS/ UL TYPE TC-ER - 90°C, 600V • MATERIAL HANDLING EQUIPMENT

CE / LOW VOLTAGE DIRECTIVE • TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE

ELECTRICAL CHARACTERISTICS CONDUCTOR COLOR CODE CONDUCTOR #1: BLUE

CONDUCTOR #3: GREEN W/YELLOW STRIPE, NUMBERED #1 CONDUCTOR #4: RED CONDUCTOR #5: WHITE CONDUCTOR #6: GREEN W/YELLOW STRIPE, NUMBERED #2

PRINT LEGEND: MOHAWK E163873 M58911 - 10 AWG (5.31 mm sq) 6 COND UL 1277 TC-ER - 600V THHN (UL) --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40237 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE)

MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA

(978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com

This document is the property of Mohawk. The information contained herein is considered proprietary and not to be

reproduced by any means without written consent of Mohawk.

Rev Description Date Init. A ADD K # TO PRINT 10/15/09 JS

Date: 07/22/09 Page 1 of 1

Part Number:

M58911 Orig: Review:

Page 14: Cable Guide

12 AWG Cable Specifications

Page 15: Cable Guide

SHEATH: .005” (.13 mm) OF NYLON

TEMP. RANGE: -25°C TO + 90°C CABLE

APPLICATIONS

• MACHINE TOOLS NOMINAL OD: .410” (10.41 mm)

• TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE LISTINGS: CSA AWM I/II A/B FT4 - 90°C, 600V

CONDUCTOR #2: WHITE W/BLACK NUMBER PRINTING

Cabling Excellence for Open Architecture

Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations.

SPECIFICATION 3 CONDUCTOR HEAVY DUTY

POWER SUPPLY CABLE

K40223 12 AWG / 3C

Jacket

Insulation

Conductor

Barrier Filler

CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 12 AWG (3.29mm2) (65/30) BARE COPPER CABLE WEIGHT: 128 lbs/1000ft (190 kg/km)

INSULATION: .016” (.41 mm) OF 105°C PVC BENDING RADIUS: 4.1” (104 mm) MIN (10 x CABLE OD)

NOMINAL DIAMETER: .135” (3.43 mm) RECOMMENDED

ASSEMBLY: 3 CONDUCTORS CABLED WITH FILLERS IN A 3.75” LEFT HAND LAY

BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, 25% OVERLAP • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING

JACKET: GRAY THERMOPLASTIC ELASTOMER • ROBOTICS AND PLANT AUTOMATION EQUIPMENT

RATINGS/ UL TYPE TC-ER - 90°C, 600V • MATERIAL HANDLING EQUIPMENT

CE / LOW VOLTAGE DIRECTIVE TRAYS - EXPOSED RUNS

CONDUCTOR COLOR CODE

ELECTRICAL CHARACTERISTICS CONDUCTOR #1: RED W/BLACK NUMBER PRINTING

CONDUCTOR DCR: .55 Ω/100m (1.67 Ω/Mft) MAX CONDUCTOR #3: GREEN W/YELLOW STRIPE

PRINT LEGEND: MOHAWK E163873 M58832 - UL 1277 TC-ER - 600V THHN (UL) 12 AWG (3.29 mm sq) 3 COND --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40223 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE)

MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA

(978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com

This document is the property of Mohawk. The information contained herein is considered proprietary and not to be

reproduced by any means without written consent of Mohawk.

Rev Description Date Init. A ADJ DIA & DCR; CORRECT STRANDING 03/28/08 JS

B ADD M # & K # 04/07/08 JS

Date: 03/26/08 Page 1 of 1

Part Number:

M58832 Orig: Review:

Page 16: Cable Guide

SHEATH: .005” (.13 mm) OF NYLON

TEMP. RANGE: -25°C TO +90°C CABLE

APPLICATIONS

• MACHINE TOOLS

RATINGS: CSA AWM I/II A/B FT4 - 90°C, 600V

CONDUCTOR #4: GREEN W/YELLOW STRIPE

Cabling Excellence for Open Architecture

Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations.

SPECIFICATION 4 CONDUCTOR HEAVY DUTY

POWER SUPPLY CABLE

K40201 12 AWG / 4C

Jacket

Braid

Insulation

Conductor

Barrier Separator

CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 12 AWG (3.29 mm2) (65/30) BARE COPPER CABLE WEIGHT: 187 lbs/1000ft (278 kg/km)

INSULATION: .016” (.41 mm) OF 105°C PVC BENDING RADIUS: 5.0” (128 mm) MIN (10 x CABLE OD)

NOMINAL DIAMETER: .135” (3.43 mm) RECOMMENDED

ASSEMBLY: 4 CONDUCTORS CABLED WITH FILLERS IN A 4.25” LEFT HAND LAY

BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, 25% OVERLAP • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING

BRAID: 34 AWG TINNED COPPER, 85% COVERAGE • ROBOTICS AND PLANT AUTOMATION EQUIPMENT

SEPARATOR: OVERALL PAPER TAPE, 25% OVERLAP • MATERIAL HANDLING EQUIPMENT

JACKET: ORANGE THERMOPLASTIC ELASTOMER • TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE NOMINAL WALL: .065" (1.65 mm) TRAYS - EXPOSED RUNS NOMINAL OD: .506” (12.85 mm)

LISTINGS/ UL TYPE TC-ER - 90°C, 600V CONDUCTOR COLOR CODE

CE - LOW VOLTAGE DIRECTIVE CONDUCTOR #1-#3: BLACK W/ NUMBER PRINTING

ELECTRICAL CHARACTERISTICS

CONDUCTOR DCR: .54 Ω/100m (1.64 Ω/Mft) MAX

PRINT LEGEND: MOHAWK E163873 M58807 12 AWG (3.29 mm sq) 4 COND SHIELDED - UL 1277 TC-ER - 600V TFFN (UL) --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40201 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE)

MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA

(978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com

This document is the property of Mohawk. The information contained herein is considered proprietary and not to be

reproduced by any means without written consent of Mohawk.

Rev Description Date Init. A UPDATE HEADER, APPLICATIONS, PRINT 07/20/07 BA B CHG RECOMMENDED TEMP RANGE TO 90°C 08/03/07 BA

Date: 05/30/07 Page 1 of 1

Part Number:

M58807 Orig: Review:

Page 17: Cable Guide

SHEATH: .005” (.13 mm) OF NYLON

TEMP. RANGE: -25°C TO +105°C CABLE

APPLICATIONS

• MATERIAL HANDLING EQUIPMENT NOMINAL OD: .474” (12.0 mm)

Cabling Excellence for Open Architecture

Mohawk reserves the right to change any specification in the interest of product enhancement.

SPECIFICATION 4 CONDUCTOR HEAVY DUTY

FLEXIBLE POWER SUPPLY CABLE

K40171 12 AWG / 4C

Jacket

Insulation

Conductor

Barrier

CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 12 AWG (3.29 mm2) (65/30) BARE COPPER CABLE WEIGHT: 189 lbs/1000ft (281 kg/km)

INSULATION: .016” (.41 mm) OF 105°C PVC BENDING RADIUS: 3.8” (96 mm) MIN (8 x CABLE OD)

NOMINAL DIAMETER: .135” (3.43 mm) RECOMMENDED

ASSEMBLY: 4 CONDUCTORS CABLED WITH FILLERS IN A 4.25” LEFT HAND LAY

BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, 25% OVERLAP • ROBOTICS AND PLANT AUTOMATION EQUIPMENT

JACKET: ORANGE THERMOPLASTIC ELASTOMER • MACHINE TOOLS

RATINGS/ UL TYPE TC-ER - 90°C, 600V CONDUCTOR COLOR CODE LISTINGS: CSA AWM I/II A/B FT4 - 90°C, 600V CONDUCTOR #1-#3: BLACK W/WHITE NUMBER PRINTING

CE / LOW VOLTAGE DIRECTIVE CONDUCTOR #4: GREEN W/YELLOW STRIPE

ELECTRICAL CHARACTERISTICS

CONDUCTOR DCR: .54 Ω/100m (1.64 Ω/Mft) MAX

PRINT LEGEND: MOHAWK E163873 M58071 - UL 1277 TC-ER - 600V THHN (UL) 12 AWG (3.29 mm sq) 4 COND --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40171 CE

MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA

(978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com

This document is the property of Mohawk. The information contained herein is considered proprietary and not to be

reproduced by any means without written consent of Mohawk.

Rev Description Date Init. D DELETE SEQ FOOTAGE MARKS & DATE CODE 12/10/03 JS E UPDATE HEADER/FOOTER, LISTINGS, PRINT 02/03/05 JS F CHANGE CSA RATING FROM 105C TO 90C 06/14/05 VB G CHANGE DIA, WT, MBR, PRINT 07/11/05 RA

Date: 03/29/01 Page 1 of 1

Part Number:

M58071 Orig: Review:

Page 18: Cable Guide

SHEATH: .005” (.13 mm) OF NYLON

TEMP. RANGE: -25°C TO +90°C CABLE

APPLICATIONS

• MACHINE TOOLS NOMINAL OD: .550” (13.97 mm)

• TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE LISTINGS: CSA AWM I/II A/B FT4 - 90°C, 600V

CONDUCTOR DCR: .54 Ω/100m (1.64 Ω/Mft) MAX

Cabling Excellence for Open Architecture

Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations.

SPECIFICATION 7 CONDUCTOR HEAVY DUTY

POWER SUPPLY CABLE

K40152 12 AWG / 7C

JACKET

CONDUCTOR

INSULATION

BARRIER

CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: 12 AWG (3.29 mm2) (65/30) BARE COPPER CABLE WEIGHT: 244 lbs/1000ft (363 kg/km)

INSULATION: .016” (.41 mm) OF 105°C PVC BENDING RADIUS: 5.5” (139 mm) MIN (10 x CABLE OD)

NOMINAL DIAMETER: .135” (3.43 mm) RECOMMENDED

ASSEMBLY: 7 CONDUCTORS CABLED TOGETHER WITH WITH A LEFT HAND LAY

BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, 25% OVERLAP • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING

JACKET: BLACK FLAME RETARDANT TPE • ROBOTICS AND PLANT AUTOMATION EQUIPMENT

RATINGS/ UL TYPE TC - 90°C, 600V • MATERIAL HANDLING EQUIPMENT

CE / LOW VOLTAGE DIRECTIVE TRAYS - EXPOSED RUNS

CONDUCTOR COLOR CODE ELECTRICAL CHARACTERISTICS CONDUCTOR #1-#6: BLACK W/WHITE NUMBER PRINTING

CONDUCTOR #7: GREEN W/YELLOW STRIPE

PRINT LEGEND: MOHAWK E163873 M57863 - UL 1277 TC-ER - 600V TFFN (UL) 12 AWG (3.29 mm sq) 7 COND SUN RES --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40152 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE)

MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA

(978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com

This document is the property of Mohawk. The information contained herein is considered proprietary and not to be

reproduced by any means without written consent of Mohawk.

Rev Description Date Init. D UPDATE FORMAT; ADD FILE #'s & UL 1277 TO PRINT 04/11/01 JS

E ADD MM SQ; UPDATE TO TC-ER PRINT; CHG TEMP 06/23/04 JS F CHANGE HEADER & FOOTER, MODIFICATIONS 02/13/07 VB G UPD HDR, TEMPS, APPS, PRINT; ADD ROHS 05/14/08 JS

Date: 03/07/00 Page 1 of 1

Part Number:

M57863 Orig: Review:

Page 19: Cable Guide

14 AWG Cable Specifications

Page 20: Cable Guide

SHEATH: .005” (.13 mm) OF NYLON

TEMP. RANGE: -25°C TO +90°C CABLE

APPLICATIONS

• MACHINE TOOLS NOMINAL OD: .360” (9.14 mm)

• TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE RATINGS: CSA AWM I/II A/B FT4 - 90°C, 600V

CONDUCTOR #3: GREEN W/YELLOW STRIPE

Cabling Excellence for Open Architecture

Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations.

SPECIFICATION 3 CONDUCTOR HEAVY DUTY

POWER SUPPLY CABLE

K40227 14 AWG / 3C

Jacket

Insulation

Conductor

Barrier Filler

CONSTRUCTION PHYSICAL CHARACTERISTICS

PRIMARIES: COND: 14 AWG (2.08 mm²) (41/30) BARE COPPER CABLE WEIGHT: 86 lbs/1000ft (128 kg/km) INSULATION: .016” (.41 mm) OF 105°C PVC BENDING RADIUS: 3.6” (91 mm) MIN (10 x CABLE OD)

NOMINAL DIAMETER: .114” (2.9 mm) RECOMMENDED

ASSEMBLY: 3 CONDUCTORS CABLED TOGETHER IN A 3.25” LEFT HAND LAY

BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, 25% OVERLAP • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING

JACKET: GRAY THERMOPLASTIC ELASTOMER • ROBOTICS AND PLANT AUTOMATION EQUIPMENT

LISTINGS/ UL TYPE TC-ER - 90°C, 600V • MATERIAL HANDLING EQUIPMENT

CE - LOW VOLTAGE DIRECTIVE TRAYS - EXPOSED RUNS

CONDUCTOR COLOR CODE ELECTRICAL CHARACTERISTICS CONDUCTOR #1: ORANGE

CONDUCTOR DCR: .86 Ω/100m (2.61 Ω/Mft) MAX CONDUCTOR #2: WHITE W/ORANGE STRIPE

PRINT LEGEND: MOHAWK E163869 M58835 14 AWG (2.08 mm sq) 3 COND - UL 1277 TC-ER - 600V THHN --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40227 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE)

MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA

(978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com

This document is the property of Mohawk. The information contained herein is considered proprietary and not to be

reproduced by any means without written consent of Mohawk.

Rev Description Date Init. A UPDATE PRINT; ADD PART NUMBER 04/28/08 JS

Date: 04/03/08 Page 1 of 1

Part Number:

M58835 Orig: Review:

Page 21: Cable Guide

SHEATH: .005” (.13 mm) OF NYLON

TEMP. RANGE: -25°C TO +90°C CABLE

APPLICATIONS

• MACHINE TOOLS NOMINAL OD: .360” (9.14 mm)

• TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE RATINGS: CSA AWM I/II A/B FT4 - 90°C, 600V

CONDUCTOR #3: GREEN W/YELLOW STRIPE

Cabling Excellence for Open Architecture

Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations.

SPECIFICATION 3 CONDUCTOR HEAVY DUTY

POWER SUPPLY CABLE

K40212 14 AWG / 3C

Jacket

Insulation

Conductor

Barrier Filler

CONSTRUCTION PHYSICAL CHARACTERISTICS

PRIMARIES: COND: 14 AWG (2.08 mm²) (41/30) BARE COPPER CABLE WEIGHT: 86 lbs/1000ft (128 kg/km) INSULATION: .016” (.41 mm) OF 105°C PVC BENDING RADIUS: 3.6” (91 mm) MIN (10 x CABLE OD)

NOMINAL DIAMETER: .114” (2.9 mm) RECOMMENDED

ASSEMBLY: 3 CONDUCTORS CABLED TOGETHER IN A 3.25” LEFT HAND LAY

BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, 25% OVERLAP • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING

JACKET: GRAY THERMOPLASTIC ELASTOMER • ROBOTICS AND PLANT AUTOMATION EQUIPMENT

LISTINGS/ UL TYPE TC-ER - 90°C, 600V • MATERIAL HANDLING EQUIPMENT

CE - LOW VOLTAGE DIRECTIVE TRAYS - EXPOSED RUNS

ELECTRICAL CHARACTERISTICS CONDUCTOR COLOR CODE CONDUCTOR DCR: .86 Ω/100m (2.61 Ω/Mft) MAX CONDUCTOR #1-#2: YELLOW W/BLACK NUMBER PRINTING

PRINT LEGEND: MOHAWK E163869 M58750 14 AWG (2.08 mm sq) 3 COND - UL 1277 TC-ER - 600V THHN --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40212 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE)

MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA

(978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com

This document is the property of Mohawk. The information contained herein is considered proprietary and not to be

reproduced by any means without written consent of Mohawk.

Rev Description Date Init. C ADDED ROHS INFORMATION 06/27/07 VB

D CHANGED CSA TEMP TO 90°C 07/11/07 VB E UPDATE HDR, BEND RADIUS, APPLICATIONS 07/10/07 BA F PERM. CHG FROM PUR/AWM TO TPE/TC-ER 04/08/08 JS

Date: 01/11/05 Page 1 of 1

Part Number:

M58750 Orig: Review:

Page 22: Cable Guide

BENDING RADIUS: 4.3" (109 mm) MIN (10 x CABLE OD) INSULATION: .016” (.41 mm) OF 105°C PVC

3.5” LEFT HAND LAY

• ROBOTICS AND PLANT AUTOMATION EQUIPMENT 25% OVERLAP ORANGE THERMOPLASTIC ELASTOMER JACKET: • MATERIAL HANDLING EQUIPMENT

ELECTRICAL CHARACTERISTICS

Cabling Excellence for Open Architecture

Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations.

SPECIFICATION 4 CONDUCTOR HEAVY DUTY

POWER SUPPLY CABLE

K40157 14 AWG / 4C

Jacket

Insulation

Conductor

Barrier

CONSTRUCTION PHYSICAL CHARACTERISTICS

PRIMARIES: COND: 14 AWG (2.08 mm2) (41/30) BARE COPPER CABLE WEIGHT: 126 lbs/1000ft (188 kg/km)

SHEATH: .005” (.13 mm) OF NYLON RECOMMENDED NOMINAL DIAMETER: .114” (2.9 mm) TEMP. RANGE: -25°C TO +90°C

CABLE ASSEMBLY: 4 CONDUCTORS CABLED TOGETHER IN A APPLICATIONS

BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING

• MACHINE TOOLS

NOMINAL OD: .426” (10.82 mm) • TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE LISTINGS/ UL TYPE TC-ER - 90°C, 600V TRAYS - EXPOSED RUNS RATINGS: CSA AWM I/II A/B FT4 - 90°C, 600V

CE / LOW VOLTAGE DIRECTIVE CONDUCTOR COLOR CODE CONDUCTOR #1-#3: BLACK W/ NUMBER PRINTING CONDUCTOR #4: GREEN W/YELLOW STRIPE

CONDUCTOR DCR: .86 Ω/100m (2.61 Ω/Mft) MAX

PRINT LEGEND: MOHAWK E163873 M58002 14 AWG (2.08 mm sq) 4 COND - UL 1277 TC-ER - 600V THHN (UL) --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40157 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE)

MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA

(978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com

This document is the property of Mohawk. The information contained herein is considered proprietary and not to be

reproduced by any means without written consent of Mohawk.

Rev Description Date Init. K CHANGED MIN BENDING RADIUS TO 10 X DIA 06/04/07 VB L ADD SEQ FT MARKS & DATE CODE 06/06/07 JS M UPD HDR, BEND RAD, APPS, PRINT; ADD ROHS 07/20/07 BA N CHG RECOMMENDED TEMP RANGE TO 90°C 08/03/07 BA

Date: 09/14/00 Page 1 of 1

Part Number:

M58002 Orig: Review:

Page 23: Cable Guide

BENDING RADIUS: 4.0” (101 mm) MIN (10 x CABLE OD) INSULATION: .016” (.41 mm) OF 105°C PVC

3.5” LEFT HAND LAY

• ROBOTICS AND PLANT AUTOMATION EQUIPMENT 25% OVERLAP GRAY THERMOPLASTIC ELASTOMER JACKET: • MATERIAL HANDLING EQUIPMENT

ELECTRICAL CHARACTERISTICS

Cabling Excellence for Open Architecture

Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations.

SPECIFICATION 4 CONDUCTOR HEAVY DUTY

POWER SUPPLY CABLE

K40093 14 AWG / 4C

Jacket

Insulation

Conductor

Barrier

CONSTRUCTION PHYSICAL CHARACTERISTICS

PRIMARIES: COND: 14 AWG (2.08 mm2) (41/30) BARE COPPER CABLE WEIGHT: 115 lbs/1000ft (171 kg/km)

SHEATH: .005” (.13 mm) OF NYLON RECOMMENDED NOMINAL DIAMETER: .114” (2.9 mm) TEMP. RANGE: -25°C TO + 90°C

CABLE ASSEMBLY: 4 CONDUCTORS CABLED TOGETHER IN A APPLICATIONS

BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING

• MACHINE TOOLS

NOMINAL OD: .399” (10.13 mm) • TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE RATINGS/ UL TYPE TC-ER - 90°C, 600V TRAYS - EXPOSED RUNS LISTINGS: CSA AWM I/II A/B FT4 - 90°C, 600V

CE / LOW VOLTAGE DIRECTIVE CONDUCTOR COLOR CODE CONDUCTOR #1-#3: BLACK W/WHITE NUMBER PRINTING CONDUCTOR #4: GREEN W/YELLOW STRIPE

CONDUCTOR DCR: .86 Ω/100m (2.61 Ω/Mft) MAX

PRINT LEGEND: MOHAWK E163873 M58829 - UL 1277 TC-ER - 600V THHN (UL) 14 AWG (2.08 mm sq) 4 COND --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40093 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE)

MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA

(978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com

This document is the property of Mohawk. The information contained herein is considered proprietary and not to be

reproduced by any means without written consent of Mohawk.

Rev Description Date Init. A CHANGE PRINT, HEADER & FOOTER 09/28/06 VB

B CHG TEMP RATINGS, CHG PRINT, ADDED ROHS 11/13/07 VB C ADD P/N & K # 03/26/08 JS

Date: 01/22/04 Page 1 of 1

Part Number:

M58829 Orig: Review:

Page 24: Cable Guide

INSULATION: .016” (.41 mm) OF 105°C PVC

TEMP. RANGE: -25°C TO +90°C NOMINAL DIAMETER: .114” (2.9 mm)

APPLICATIONS 4.0” LEFT HAND LAY

25% OVERLAP • ROBOTICS AND PLANT AUTOMATION EQUIPMENT

TRAYS - EXPOSED RUNS LISTINGS: CSA AWM I/II A/B FT4 - 90°C, 600V

ELECTRICAL CHARACTERISTICS CONDUCTOR #5: GREEN W/YELLOW STRIPE

Cabling Excellence for Open Architecture

Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations.

SPECIFICATION 5 CONDUCTOR HEAVY DUTY

POWER SUPPLY CABLE

K40096 14 AWG / 5C

JACKET

CONDUCTOR

INSULATION

BARRIER

CONSTRUCTION PHYSICAL CHARACTERISTICS

PRIMARIES: COND: 14 AWG (2.08 mm²) (41/30) BARE CABLE WEIGHT: 136 lbs/1000ft (201 kg/km) COPPER BENDING RADIUS: 4.3” (109 mm) MIN (10 x CABLE OD)

SHEATH: .005” (.13 mm) OF NYLON RECOMMENDED

CABLE ASSEMBLY: 5 CONDUCTORS CABLED TOGETHER IN A

BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING

JACKET: GRAY THERMOPLASTIC ELASTOMER • MACHINE TOOLS

NOMINAL OD: .432” (10.97 mm) • MATERIAL HANDLING EQUIPMENT

RATINGS/ UL TYPE TC-ER - 90°C, 600V • TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE

CE / LOW VOLTAGE DIRECTIVE CONDUCTOR COLOR CODE CONDUCTOR #1-#4: DK. BLUE W/WHITE NUMBER PRINTING

CONDUCTOR DCR: .86 Ω/100m (2.61 Ω/Mft) MAX

PRINT LEGEND: MOHAWK E163873 M58830 - UL 1277 TC-ER - 600V THHN (UL) 14 AWG (2.08 mm sq) 5 COND --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40096 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE)

MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA

(978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com

This document is the property of Mohawk. The information contained herein is considered proprietary and not to be

reproduced by any means without written consent of Mohawk.

Rev Description Date Init. A CHANGE HEADER, FOOTER & PRINT 09/28/06 VB

B CHG TEMP RATINGS, CHG PRINT, ADDED ROHS 11/13/07 VB C ADD P/N & K # 03/26/08 JS

Date: 01/22/04 Page 1 of 1

Part Number:

M58830 Orig: Review:

Page 25: Cable Guide

BENDING RADIUS: 5.0” (127 mm) MIN (10 x CABLE OD) SHEATH: .005” (.13 mm) OF NYLON

25% OVERLAP ORANGE THERMOPLASTIC ELASTOMER JACKET: • ROBOTICS AND PLANT AUTOMATION EQUIPMENT

• TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE LISTINGS: CSA AWM I/II A/B FT4 - 90°C, 600V

ELECTRICAL CHARACTERISTICS

Cabling Excellence for Open Architecture

Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations.

SPECIFICATION 7 CONDUCTOR HEAVY DUTY

POWER SUPPLY CABLE

K40129 14 AWG / 7C

JACKET

CONDUCTOR

INSULATION

BARRIER

CONSTRUCTION PHYSICAL CHARACTERISTICS

PRIMARIES: COND: 14 AWG (2.08 mm²) (41/30) BARE COPPER CABLE WEIGHT: 178 lbs/1000ft (265 kg/km) INSULATION: .016” (.41 mm) OF 105°C PVC

NOMINAL DIAMETER: .114” (2.9 mm) RECOMMENDED

CABLE 7 CONDUCTORS CABLED TOGETHER IN A TEMP. RANGE: -25°C TO +90°C ASSEMBLY: 4.50” LEFT HAND LAY

BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, APPLICATIONS

• STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING

NOMINAL OD: .495” (12.57 mm) • MACHINE TOOLS

RATINGS/ UL TYPE TC-ER - 90°C, 600V • MATERIAL HANDLING EQUIPMENT

CE / LOW VOLTAGE DIRECTIVE TRAYS - EXPOSED RUNS

CONDUCTOR COLOR CODE CONDUCTOR #1-#6: BLACK W/WHITE NUMBER PRINTING

CONDUCTOR DCR: .86 Ω/100m (2.61 Ω/Mft) MAX CONDUCTOR #7: GREEN W/YELLOW STRIPE

PRINT LEGEND: MOHAWK E163873 M58942 - UL 1277 TC-ER - 600V THHN (UL) 14 AWG (2.08 mm sq) 7 COND --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40129 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE)

MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA

(978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com

This document is the property of Mohawk. The information contained herein is considered proprietary and not to be

reproduced by any means without written consent of Mohawk.

Rev Description Date Init. A ADJUST JKT DIA, CABLE WGT, BEND RADIUS 12/10/09 JS

B UPDATE PRINT WITH M # AND K # 12/11/09 JS

Date: 12/07/09 Page 1 of 1

Part Number:

- Orig: Review:

Page 26: Cable Guide

16 AWG Cable Specifications

Page 27: Cable Guide

SHEATH: .0045” (.11 mm) OF NYLON

TEMP. RANGE: -25°C TO + 90°C CABLE

APPLICATIONS

• MACHINE TOOLS NOMINAL OD: .337” (8.56 mm)

• TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE LISTINGS: CSA AWM I/II A/B FT4 - 90°C, 600V

CONDUCTOR #3: GREEN W/YELLOW STRIPE

Cabling Excellence for Open Architecture

Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations.

SPECIFICATION 3 CONDUCTOR HEAVY DUTY

POWER SUPPLY CABLE

K40240 16 AWG / 3C

Jacket

Insulation

Conductor

Barrier Filler

CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 16 AWG (1.31mm2) (65/34) BARE COPPER CABLE WEIGHT: 73 lbs/1000ft (108 kg/km)

INSULATION: .016” (.41 mm) OF 105°C PVC BENDING RADIUS: 3.3” (84 mm) MIN (10 x CABLE OD)

NOMINAL DIAMETER: .101” (2.57 mm) RECOMMENDED

ASSEMBLY: 3 CONDUCTORS CABLED WITH FILLERS IN A 2.75” LEFT HAND LAY

BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, 25% OVERLAP • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING

JACKET: GRAY THERMOPLASTIC ELASTOMER • ROBOTICS AND PLANT AUTOMATION EQUIPMENT

RATINGS/ UL TYPE TC-ER - 90°C, 600V • MATERIAL HANDLING EQUIPMENT

CE / LOW VOLTAGE DIRECTIVE TRAYS - EXPOSED RUNS

CONDUCTOR COLOR CODE

ELECTRICAL CHARACTERISTICS CONDUCTOR #1-#2: ORANGE W/BLACK NUMBER PRINTING

CONDUCTOR DCR: 1.46 Ω/100m (4.44 Ω/Mft) MAX

PRINT LEGEND: MOHAWK E163873 M 16 AWG (1.31 mm sq) 3 COND - UL 1277 TC-ER - 600V TFFN (UL) --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE)

MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA

(978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com

This document is the property of Mohawk. The information contained herein is considered proprietary and not to be

reproduced by any means without written consent of Mohawk.

Rev Description Date Init. A MODIFY PRINT 10/12/09 JS

Date: 03/11/08 Page 1 of 1

Part Number:

- Orig: Review:

Page 28: Cable Guide

SHEATH: .0045” (.11 mm) OF NYLON

TEMP. RANGE: -30°C TO +105°C CABLE

APPLICATIONS

• MATERIAL HANDLING EQUIPMENT NOMINAL OD: .337” (8.56 mm)

CONDUCTOR COLOR CODE LISTINGS: CSA AWM I/II A/B FT4 - 105°C, 600V

Cabling Excellence for Open Architecture

Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations.

SPECIFICATION 3 CONDUCTOR HEAVY DUTY

FLEXIBLE POWER SUPPLY CABLE

K40127 16 AWG / 3C

Jacket

Insulation

Conductor

Barrier Filler

CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 16 AWG (1.31mm2) (65/34) BARE COPPER CABLE WEIGHT: 73 lbs/1000ft (108 kg/km)

INSULATION: .016” (.41 mm) OF 105°C PVC BENDING RADIUS: 2.7” (68 mm) MIN (8 x CABLE OD)

NOMINAL DIAMETER: .099” (2.51 mm) RECOMMENDED

ASSEMBLY: 3 CONDUCTORS CABLED WITH FILLERS IN A 2.75” LEFT HAND LAY

BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, 25% OVERLAP • ROBOTICS AND PLANT AUTOMATION EQUIPMENT

JACKET: GRAY THERMOPLASTIC ELASTOMER • MACHINE TOOLS

RATINGS/ UL TYPE TC-ER - 90°C, 600V

CE / LOW VOLTAGE DIRECTIVE CONDUCTOR #1-#2: YELLOW W/BLACK NUMBER PRINTING CONDUCTOR #3: GREEN W/YELLOW STRIPE

ELECTRICAL CHARACTERISTICS

CONDUCTOR DCR: 1.46 Ω/100m (4.44 Ω/Mft) MAX

PRINT LEGEND: MOHAWK E83542 M58792 - UL 1277 TC-ER - 600V TFFN (UL) 16 AWG (1.31 mm sq) 3 COND --- LL34280 CSA AWM I/II A/B 105C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40127 CE

MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA

(978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com

This document is the property of Mohawk. The information contained herein is considered proprietary and not to be

reproduced by any means without written consent of Mohawk.

Rev Description Date Init. A ADD P/N & ROHS; UPDATE LISTINGS, PRINT 04/27/07 JS

Date: 01/22/04 Page 1 of 1

Part Number:

M58792 Orig: Review:

Page 29: Cable Guide

SHEATH: .0045” (.11 mm) OF NYLON

TEMP. RANGE: -25°C TO +90°C CABLE

APPLICATIONS

• MACHINE TOOLS NOMINAL OD: .363” (9.22 mm)

• TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE LISTINGS: CSA AWM I/II A/B FT4 - 90°C, 600V

CONDUCTOR DCR: 1.46 Ω/100m (4.44 Ω/Mft) MAX

Cabling Excellence for Open Architecture

Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations.

SPECIFICATION 4 CONDUCTOR HEAVY DUTY

POWER SUPPLY CABLE

K40159 16 AWG / 4C

Jacket

Insulation

Conductor

Barrier

CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 16 AWG (1.31 mm2) (65/34) BARE COPPER CABLE WEIGHT: 90 lbs/1000ft (134 kg/km)

INSULATION: .016” (.41 mm) OF 105°C PVC BENDING RADIUS: 3.6” (91 mm) MIN (10 x CABLE OD)

NOMINAL DIAMETER: .099” (2.51 mm) RECOMMENDED

ASSEMBLY: 4 CONDUCTORS CABLED WITH FILLERS IN A 3.0” LEFT HAND LAY

BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, 25% OVERLAP • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING

JACKET: GRAY THERMOPLASTIC ELASTOMER • ROBOTICS AND PLANT AUTOMATION EQUIPMENT

RATINGS/ UL TYPE TC-ER - 90°C, 600V • MATERIAL HANDLING EQUIPMENT

CE / LOW VOLTAGE DIRECTIVE TRAYS - EXPOSED RUNS

CONDUCTOR COLOR CODE ELECTRICAL CHARACTERISTICS CONDUCTOR #1-#3: BLUE W/WHITE NUMBER PRINTING

CONDUCTOR #4: GREEN W/YELLOW STRIPE

PRINT LEGEND: MOHAWK E163873 M58793 - UL 1277 TC-ER - 600V TFFN (UL) 16 AWG (1.31 mm sq) 4 COND --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40159 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE)

MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA

(978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com

This document is the property of Mohawk. The information contained herein is considered proprietary and not to be

reproduced by any means without written consent of Mohawk.

Rev Description Date Init. A ADD P/N & ROHS; UPDATE LISTINGS, PRINT, WGT 04/27/07 JS B CHG FILE # ON PRINT, TEMP RATING, CHG HEADER 07/25/07 VB C CHG RECOMMENDED TEMP RANGE TO 90°C 08/01/07 VB

Date: 01/22/04 Page 1 of 1

Part Number:

M58793 Orig: Review:

Page 30: Cable Guide

SHEATH: .0045” (.11 mm) OF NYLON

TEMP. RANGE: -30°C TO +105°C CABLE

APPLICATIONS

• MATERIAL HANDLING EQUIPMENT

CONDUCTOR COLOR CODE RATINGS/ UL TYPE TC-ER - 90°C, 600V

Cabling Excellence for Open Architecture

Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations.

SPECIFICATION 4 CONDUCTOR HEAVY DUTY

FLEXIBLE POWER SUPPLY CABLE

K40221 16 AWG / 4C

Jacket

Insulation

Conductor

Barrier

Braid

CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 16 AWG (1.31 mm2) (65/34) BARE COPPER CABLE WEIGHT: 104 lbs/1000ft (155 kg/km)

INSULATION: .016” (.41 mm) OF 105°C PVC BENDING RADIUS: 3.9” (99 mm) MIN (8 x CABLE OD)

NOMINAL DIAMETER: .099” (2.51 mm) RECOMMENDED

ASSEMBLY: 4 CONDUCTORS CABLED TOGETHER WITH FILLERS IN A 3.0" LEFT HAND LAY

BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, 25% OVERLAP • ROBOTICS AND PLANT AUTOMATION EQUIPMENT

BRAID: #36 AWG TINNED COPPER, 65% COVERAGE • MACHINE TOOLS

JACKET: ORANGE THERMOPLASTIC ELASTOMER NOMINAL OD: .385” (9.78 mm)

LISTINGS: CSA AWM I/II A/B FT4 - 105°C, 600V CONDUCTOR #1-#3: BLACK W/WHITE NUMBER PRINTING

CE / LOW VOLTAGE DIRECTIVE CONDUCTOR #4: GREEN W/YELLOW STRIPE

ELECTRICAL CHARACTERISTICS

CONDUCTOR DCR: 1.46 Ω/100m (4.44 Ω/Mft) MAX

PRINT LEGEND: MOHAWK E83542 M58796 - UL 1277 TC-ER - 600V TFFN (UL) 16 AWG (1.31 mm sq) 4 COND --- LL34280 CSA AWM I/II A/B 105C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40221 CE

MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA

(978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com

This document is the property of Mohawk. The information contained herein is considered proprietary and not to be

reproduced by any means without written consent of Mohawk.

Rev Description Date Init. A UPDATE PRINT; ADD PART NUMBER 05/08/07 JS

Date: 05/02/07 Page 1 of 1

Part Number:

M58796 Orig: Review:

Page 31: Cable Guide

SHEATH: .005” (.13 mm) OF NYLON

TEMP. RANGE: -25°C TO +90°C CABLE

APPLICATIONS

• MACHINE TOOLS NOMINAL OD: .445” (11.30 mm)

• TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE LISTINGS: CSA AWM I/II A/B FT4 - 90°C, 600V

CONDUCTOR #7: GREEN W/YELLOW STRIPE

Cabling Excellence for Open Architecture

Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations.

SPECIFICATION 7 CONDUCTOR HEAVY DUTY

POWER SUPPLY CABLE

K40238 16 AWG / 7C

JACKET

CONDUCTOR

INSULATION

BARRIER

CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 16 AWG (1.31 mm2) (65/34) BARE COPPER CABLE WEIGHT: 129 lbs/1000ft (192 kg/km)

INSULATION: .016” (.41 mm) OF 105°C PVC BENDING RADIUS: 4.2” (107 mm) MIN (10 x CABLE OD)

NOMINAL DIAMETER: .101” (2.57 mm) RECOMMENDED

ASSEMBLY: 7 CONDUCTORS CABLED TOGETHER WITH A LEFT HAND LAY

BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, 25% OVERLAP • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING

JACKET: GRAY THERMOPLASTIC ELASTOMER • ROBOTICS AND PLANT AUTOMATION EQUIPMENT

RATINGS/ UL TYPE TC-ER - 90°C, 600V • MATERIAL HANDLING EQUIPMENT

CE / LOW VOLTAGE DIRECTIVE TRAYS - EXPOSED RUNS

CONDUCTOR COLOR CODE ELECTRICAL CHARACTERISTICS CONDUCTOR #1-#6: ORANGE W/BLACK NUMBER PRINTING

CONDUCTOR DCR: 1.46 Ω/100m (4.44 Ω/Mft) MAX

PRINT LEGEND: MOHAWK E163873 M 16 AWG (1.31 mm sq) 7 COND - UL 1277 TC-ER - 600V TFFN (UL) --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE)

MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA

(978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com

This document is the property of Mohawk. The information contained herein is considered proprietary and not to be

reproduced by any means without written consent of Mohawk.

Rev Description Date Init. A MODIFY PRINT 10/12/09 JS

Date: 03/11/08 Page 1 of 1

Part Number:

- Orig: Review:

Page 32: Cable Guide

SHEATH: .005” (.13 mm) OF NYLON

TEMP. RANGE: -25°C TO +90°C CABLE

APPLICATIONS

• MACHINE TOOLS NOMINAL OD: .444” (11.28 mm)

• TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE LISTINGS: CSA AWM I/II A/B FT4 - 90°C, 600V

CONDUCTOR #7: GREEN W/YELLOW STRIPE

Cabling Excellence for Open Architecture

Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations.

SPECIFICATION 7 CONDUCTOR HEAVY DUTY

POWER SUPPLY CABLE

K40215 16 AWG / 7C

JACKET

CONDUCTOR

INSULATION

BARRIER

CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 16 AWG (1.31 mm2) (65/34) BARE COPPER CABLE WEIGHT: 129 lbs/1000ft (192 kg/km)

INSULATION: .016” (.41 mm) OF 105°C PVC BENDING RADIUS: 4.2” (107 mm) MIN (10 x CABLE OD)

NOMINAL DIAMETER: .100” (2.54 mm) RECOMMENDED

ASSEMBLY: 7 CONDUCTORS CABLED TOGETHER WITH A LEFT HAND LAY

BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, 25% OVERLAP • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING

JACKET: GRAY THERMOPLASTIC ELASTOMER • ROBOTICS AND PLANT AUTOMATION EQUIPMENT

RATINGS/ UL TYPE TC-ER - 90°C, 600V • MATERIAL HANDLING EQUIPMENT

CE / LOW VOLTAGE DIRECTIVE TRAYS - EXPOSED RUNS

CONDUCTOR COLOR CODE ELECTRICAL CHARACTERISTICS CONDUCTOR #1-#6: DK. BLUE W/WHITE NUMBER PRINTING

CONDUCTOR DCR: 1.46 Ω/100m (4.44 Ω/Mft) MAX

PRINT LEGEND: MOHAWK E163873 M58715 - UL 1277 TC-ER - 600V TFFN (UL) 16 AWG (1.31 mm sq) 7 COND --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40215 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE)

MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA

(978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com

This document is the property of Mohawk. The information contained herein is considered proprietary and not to be

reproduced by any means without written consent of Mohawk.

Rev Description Date Init. A UPDATE PRINT; ADD K # & P/N 01/04/06 JS B REVISE PRINT 09/28/06 VB C CHG TEMP RATINGS, CHG PRINT, ADDED ROHS 11/13/07 VB D INCREASE OVERALL CABLE DIAMETER 01/11/08 VB

Date: 08/24/05 Page 1 of 1

Part Number:

M58715 Orig: Review:

Page 33: Cable Guide

SHEATH: .0045” (.11 mm) OF NYLON

TEMP. RANGE: -25°C TO +105°C CABLE

APPLICATIONS

• MATERIAL HANDLING EQUIPMENT NOMINAL OD: .418” (10.62 mm)

CONDUCTOR COLOR CODE RATINGS: CSA AWM I/II A/B FT4 - 90°C, 600V

Cabling Excellence for Open Architecture

Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations.

SPECIFICATION 7 CONDUCTOR HEAVY DUTY

FLEXIBLE POWER SUPPLY CABLE

K40181 16 AWG / 7C

JACKET

CONDUCTOR

INSULATION

BARRIER

CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 16 AWG (1.31 mm2) (65/34) BARE COPPER CABLE WEIGHT: 121 lbs/1000ft (180 kg/km)

INSULATION: .016” (.41 mm) OF 105°C PVC BENDING RADIUS: 4.2” (107 mm) MIN (10 x CABLE OD)

NOMINAL DIAMETER: .099” (2.51 mm) RECOMMENDED

ASSEMBLY: 7 CONDUCTORS CABLED TOGETHER IN A 3.75” LEFT HAND LAY

BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, 25% OVERLAP • ROBOTICS AND PLANT AUTOMATION EQUIPMENT

JACKET: GRAY THERMOPLASTIC ELASTOMER • MACHINE TOOLS

LISTING/ UL TYPE TC-ER - 90°C, 600V

CE - LOW VOLTAGE DIRECTIVE CONDUCTOR #1-#6: RED W/BLACK NUMBER PRINTING CONDUCTOR #7: GREEN W/YELLOW STRIPE

ELECTRICAL CHARACTERISTICS

CONDUCTOR DCR: 1.46 Ω/100m (4.44 Ω/Mft) MAX

PRINT LEGEND: MOHAWK E163873 M58107 16 AWG (1.31 mm sq) 7 COND - UL 1277 TC-ER - 600V TFFN (UL) --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40181 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & YEAR/SHOP ORDER CODE)

MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA

(978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com

This document is the property of Mohawk. The information contained herein is considered proprietary and not to be

reproduced by any means without written consent of Mohawk.

Rev Description Date Init. B UPDATE PRINT 01/04/05 JS

C CHG PUR TO TPE, AWM TO TC-ER, ADDED ROHS 05/17/07 VB D CHANGED TEMP & FILE NOS. 05/24/07 VB E CHANGED DIA TO .418" AND MIN BEND RADIUS 06/04/07 VB

Date: 05/16/01 Page 1 of 1

Part Number:

M58107 Orig: Review:

Page 34: Cable Guide

SHEATH: .0045” (.11 mm) OF NYLON

TEMP. RANGE: -25°C TO +90°C CABLE

APPLICATIONS

• MACHINE TOOLS NOMINAL OD: .428” (10.87 mm)

• TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE RATINGS: CSA AWM I/II A/B FT4 - 90°C, 600V

CONDUCTOR DCR: 1.46 Ω/100m (4.44 Ω/Mft) MAX

Cabling Excellence for Open Architecture

Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations.

SPECIFICATION 7 CONDUCTOR HEAVY DUTY

POWER SUPPLY CABLE

K40208 16 AWG / 7C

JACKET

CONDUCTOR

INSULATION

BARRIER

CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 16 AWG (1.31 mm2) (65/34) BARE COPPER CABLE WEIGHT: 121 lbs/1000ft (180 kg/km)

INSULATION: .016” (.41 mm) OF 105°C PVC BENDING RADIUS: 4.3” (109 mm) MIN (10 x CABLE OD)

NOMINAL DIAMETER: .099” (2.51 mm) RECOMMENDED

ASSEMBLY: 7 CONDUCTORS CABLED TOGETHER IN A 3.75” LEFT HAND LAY

BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, 25% OVERLAP • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING

JACKET: GRAY THERMOPLASTIC ELASTOMER • ROBOTICS AND PLANT AUTOMATION EQUIPMENT

LISTINGS/ UL TYPE TC-ER - 90°C, 600V • MATERIAL HANDLING EQUIPMENT

CE - LOW VOLTAGE DIRECTIVE TRAYS - EXPOSED RUNS

CONDUCTOR COLOR CODE ELECTRICAL CHARACTERISTICS CONDUCTOR #1-#6: YELLOW W/BLACK NUMBER PRINTING

CONDUCTOR #7: GREEN W/YELLOW STRIPE

PRINT LEGEND: MOHAWK E163873 M58599 16 AWG (1.31 mm sq) 7 COND - UL 1277 TC-ER - 600V TFFN (UL) --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40208 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE)

MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA

(978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com

This document is the property of Mohawk. The information contained herein is considered proprietary and not to be

reproduced by any means without written consent of Mohawk.

Rev Description Date Init. C UPDATE PRINT & TEMPERATURES 06/01/07 JS D CHANGED OVERALL DIA TO .428" O.D. 06/08/07 VB E UPDATE HDR, BEND RADIUS, APPS, DATE CODE 07/20/07 BA F CHG RECOMMENDED TEMP RANGE TO 90°C 08/03/07 BA

Date: 10/26/04 Page 1 of 1

Part Number:

M58599 Orig: Review:

Page 35: Cable Guide

SHEATH: .0045” (.11 mm) OF NYLON

TEMP. RANGE: -30°C TO +105°C CABLE

APPLICATIONS

• MATERIAL HANDLING EQUIPMENT NOMINAL OD: .550” (13.97 mm)

CONDUCTOR COLOR CODE RATINGS: CSA AWM I/II A/B FT4 - 105C, 600V

Cabling Excellence for Open Architecture

Mohawk reserves the right to change any specification in the interest of product enhancement.

SPECIFICATION 12 CONDUCTOR HEAVY DUTY FLEXIBLE POWER SUPPLY CABLE

K40210 16 AWG / 12C

JACKET

CONDUCTOR

INSULATION BARRIER

CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 16 AWG (1.31mm2) (65/34) BARE COPPER CABLE WEIGHT: 215 lbs/1000ft (318 kg/km)

INSULATION: .016” (.41 mm) OF 105°C PVC BENDING RADIUS: 4.4” (111 mm) MIN (8 x CABLE OD)

NOMINAL DIAMETER: .099” (2.51 mm) RECOMMENDED

ASSEMBLY: 12 CONDUCTORS CABLED TOGETHER IN A 5.25” LEFT HAND LAY

BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, 25% OVERLAP • ROBOTICS AND PLANT AUTOMATION EQUIPMENT

JACKET: GRAY THERMOPLASTIC ELASTOMER • MACHINE TOOLS

LISTING/ UL TYPE TC-ER - 90C, 600V

CE - LOW VOLTAGE DIRECTIVE CONDUCTOR #1-#11: RED W/BLACK NUMBER PRINTING CONDUCTOR #12: GREEN W/YELLOW STRIPE

ELECTRICAL CHARACTERISTICS

CONDUCTOR DCR: 1.46 Ω/100m (4.44 Ω/Mft) MAX

PRINT LEGEND: MOHAWK E83542 M58601 16 AWG (1.31 mm sq) 12 COND - UL 1277 TC-ER - 600V TFFN (UL) --- LL34280 CSA AWM I/II A/B 105C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40210 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & YEAR/SHOP ORDER CODE)

MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA

(978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com

This document is the property of Mohawk. The information contained herein is considered proprietary and not to be

reproduced by any means without written consent of Mohawk.

Rev Description Date Init. A ADD PART NUMBER; UPDATE PRINT 01/04/05 JS B CHG PUR TO TPE, AWM TO TC-ER, ADDED ROHS 05/21/07 VB

Date: 12/22/04 Page 1 of 1

Part Number:

M58601 Orig: Review:

Page 36: Cable Guide

SHEATH: .0045” (.11 mm) OF NYLON

TEMP. RANGE: -25°C TO +90°C CABLE

APPLICATIONS

• MACHINE TOOLS NOMINAL OD: .535” (13.59 mm)

• TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE RATINGS: CSA AWM I/II A/B FT4 - 90C, 600V

ELECTRICAL CHARACTERISTICS CONDUCTOR #1-#11: YELLOW W/BLACK NUMBER PRINTING

Cabling Excellence for Open Architecture

Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations.

SPECIFICATION 12 CONDUCTOR HEAVY DUTY

POWER SUPPLY CABLE

K40216 16 AWG / 12C

JACKET

CONDUCTOR

INSULATION BARRIER

CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 16 AWG (1.31mm2) (65/34) BARE COPPER CABLE WEIGHT: 199 lbs/1000ft (296 kg/km)

INSULATION: .016” (.41 mm) OF 105°C PVC BENDING RADIUS: 5.35” (136 mm) MIN (10 x CABLE OD)

NOMINAL DIAMETER: .099” (2.51 mm) RECOMMENDED

ASSEMBLY: 12 CONDUCTORS CABLED TOGETHER IN A 5.25” LEFT HAND LAY

BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, 25% OVERLAP • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING

JACKET: GRAY FLAME RETARDANT TPE • ROBOTICS AND PLANT AUTOMATION EQUIPMENT

LISTING/ UL TYPE TC-ER - 90C, 600V • MATERIAL HANDLING EQUIPMENT

CE - LOW VOLTAGE DIRECTIVE TRAYS - EXPOSED RUNS

CONDUCTOR COLOR CODE

CONDUCTOR DCR: 1.46 Ω/100m (4.44 Ω/Mft) MAX CONDUCTOR #12: GREEN W/YELLOW STRIPE

PRINT LEGEND: MOHAWK E163873 M58716 16 AWG (1.31 mm sq) 12 COND - UL 1277 TC-ER - 600V TFFN (UL) --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40216 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE)

MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA

(978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com

This document is the property of Mohawk. The information contained herein is considered proprietary and not to be

reproduced by any means without written consent of Mohawk.

Rev Description Date Init. A UPDATE PRINT; ADD K # & P/N 01/04/06 JS

B UPD HDR, PRINT, TEMPS, APPS, BEND; ADD ROHS 09/02/08 JS

Date: 08/24/05 Page 1 of 1

Part Number:

M58716 Orig: Review:

Page 37: Cable Guide

SHEATH: .005” (.13 mm) OF NYLON

TEMP. RANGE: -25°C TO +90°C CABLE

APPLICATIONS

• MACHINE TOOLS NOMINAL OD: .565” (14.35 mm)

• TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE RATINGS: CSA AWM I/II A/B FT4 - 90°C, 600V

CONDUCTOR DCR: 1.46 Ω/100m (4.44 Ω/Mft) MAX

Cabling Excellence for Open Architecture

Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations.

SPECIFICATION 12 CONDUCTOR HEAVY DUTY

POWER SUPPLY CABLE

K40052 16 AWG / 12C

JACKET

CONDUCTOR

INSULATION BARRIER

CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 16 AWG (1.31mm2) (65/34) BARE COPPER CABLE WEIGHT: 216 lbs/1000ft (321 kg/km)

INSULATION: .016” (.41 mm) OF 105°C PVC BENDING RADIUS: 5.5” (140 mm) MIN (10 x CABLE OD)

NOMINAL DIAMETER: .101” (2.56 mm) RECOMMENDED

ASSEMBLY: 12 CONDUCTORS CABLED TOGETHER IN A 5.25” LEFT HAND LAY

BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, 25% OVERLAP • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING

JACKET: GRAY THERMOPLASTIC ELASTOMER • ROBOTICS AND PLANT AUTOMATION EQUIPMENT

LISTING/ UL TYPE TC-ER - 90°C, 600V • MATERIAL HANDLING EQUIPMENT

CE - LOW VOLTAGE DIRECTIVE TRAYS - EXPOSED RUNS

CONDUCTOR COLOR CODE ELECTRICAL CHARACTERISTICS CONDUCTOR #1-#11: DK. BLUE W/WHITE NUMBER PRINTING

CONDUCTOR #12: GREEN W/YELLOW STRIPE

PRINT LEGEND: MOHAWK E163873 M56561 16 AWG (1.31 mm sq) 12 COND - UL 1277 TC-ER - 600V TFFN (UL) --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40052 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & YEAR/SHOP ORDER CODE)

MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA

(978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com

This document is the property of Mohawk. The information contained herein is considered proprietary and not to be

reproduced by any means without written consent of Mohawk.

Rev Description Date Init. I UPDATE PRINT FOR mm sq & SQ FOOTAGE MARKS 05/08/02 JS

J UPDATE HEADER/FOOTER, WGT, PRINT 06/08/05 JS K CHG PUR TO TPE, AWM TO TC-ER, ADJ DIA/WGT 08/20/07 VB L ADJ COND NOM DIA, ADJ FINAL OD 08/28/07 VB

Date: 07/17/95 Page 1 of 1

Part Number:

M56561 Orig: Review:

Page 38: Cable Guide

GENERAL PRODUCT SPECIFICATION Phone 800-316-8877 Fax 978-368-1275

www.jamesmonroewire.com

Description: Eighteen Conductor, 16 AWG, Tray Cable-ER PP Foam Tape and Overall TPE Jacket

Date: 9/2/2008

Cable Diagram

Jacket

Binder Insulated Conductor

Components Eighteen 16 AWG Insulated Conductors

Conductor: 16 AWG, 65/34 bare copper

Insulation: .016" nominal wall of PVC (See Color Code)

Nylon Jacket: .005" nominal wall of Clear Nylon .100"

Cable Construction

Cabling: Eighteen conductors cabled together around solid PVC filler with contra-helical lays

Binder: Foam Propylene tape

Jacket: .072" nominal wall of Gray TPE .657" (.690" max)

Print JMWCC E73202 18/C 16 AWG (1.31 mm 2) TC-ER 90C DRY 75C WET 600V (UL) - - - LL41103 CSA AWM I/II A/B 90C 600V FT4 - - - ELECTRIVERT FLEX-LINK SERIES K40233 CE (with Sequential Footage Marks every 2 feet)

Color Code Conductors 1 thru 17:

Conductor 18: Yellow and numerically printed Green/Yellow ground

Requirements Temperature: 90°C

Voltage: 600V Approvals: UL Type TC-ER

CSA AWM, I/II, A/B CE - LVD RoHS Compliant

File:Public\JMWC_Ref\Spec\JMEVT40233-18C16-65str-TPE-TC.xls

Written By: RA 9/2/2008 Rev. 0 Initial Issue Revised By: Revised By: Revised By:

K40233 16 AWG / 18C

Page 39: Cable Guide

SHEATH: .005” (.13 mm) OF NYLON

TEMP. RANGE: -25°C TO +90°C

STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING

NOMINAL OD: .690” (17.53 mm) MACHINE TOOLS

ELECTRICAL CHARACTERISTICS

Cabling Excellence for Open Architecture

Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations.

SPECIFICATION

19 CONDUCTOR HEAVY DUTY POWER SUPPLY CABLE

K40014 16 AWG / 19C

JACKET

CONDUCTOR

INSULATION

BARRIER

CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 16 AWG (1.31 mm2) (65/34) BARE COPPER CABLE WEIGHT: 355 lbs/1000ft (528 kg/km)

INSULATION: .016” (.41 mm) OF 105°C PVC BENDING RADIUS: 6.9” (175 mm) MIN (10 x CABLE OD)

NOMINAL DIAMETER: .101” (2.56 mm) RECOMMENDED

CABLE 19 CONDUCTORS AND FILLERS CABLED ASSEMBLY: TOGETHER WITH CONTRA-HELICAL LAYS

BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, APPLICATIONS 25% OVERLAP

JACKET: GRAY THERMOPLASTIC ELASTOMER ROBOTICS AND PLANT AUTOMATION EQUIPMENT

RATINGS/ UL TYPE TC-ER - 90°C, 600V MATERIAL HANDLING EQUIPMENT LISTINGS: CSA AWM I/II A/B FT4 - 90°C, 600V TC-ER COMPLIANT FOR CABLES EXTENDED FROM

CE / LOW VOLTAGE DIRECTIVE CABLE TRAYS - EXPOSED RUNS

CONDUCTOR COLOR CODE CONDUCTOR #1-#18: DK. BLUE W/WHITE NUMBER PRINTING

CONDUCTOR DCR: 1.46 /100m (4.44 /Mft) MAX CONDUCTOR #19: GREEN W/YELLOW STRIPE

PRINT LEGEND: MOHAWK E163873 M 16 AWG (1.31 mm sq) 19 COND - UL 1277 TC-ER - 600V TFFN (UL) --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE)

MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA

(978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com

This document is the property of Mohawk. The information contained herein is considered proprietary and not to be

reproduced by any means without written consent of Mohawk.

Rev Description Date Init.

A ADJUST DIAMETER, CABLE WGT, BEND RADIUS 01/07/10 JS

Date: 01/04/10 Page 1 of 1

Part Number:

- Orig: Review:

Page 40: Cable Guide

SHEATH: .005” (.13 mm) OF NYLON

TEMP. RANGE: -25°C TO +90°C CABLE

APPLICATIONS

• MACHINE TOOLS NOMINAL OD: .793” (20.14 mm)

• TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE LISTINGS: CSA AWM I/II A/B FT4 - 90°C, 600V

CONDUCTOR DCR: 1.46 Ω/100m (4.44 Ω/Mft) MAX

Cabling Excellence for Open Architecture

Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations.

SPECIFICATION 25 CONDUCTOR HEAVY DUTY

POWER SUPPLY CABLE

K40049 16 AWG / 25C

JACKET CONDUCTOR

INSULATION BARRIER

CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 16 AWG (1.31mm2) (65/34) BARE COPPER CABLE WEIGHT: 438 lbs/1000ft (652 kg/km)

INSULATION: .016” (.41 mm) OF 105°C PVC BENDING RADIUS: 7.9” (201 mm) MIN (10 x CABLE OD)

NOMINAL DIAMETER: .101” (2.56 mm) RECOMMENDED

ASSEMBLY: 25 CONDUCTORS AND FILLERS CABLED TOGETHER WITH CONTRA-HELICAL LAYS

BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, 25% OVERLAP • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING

JACKET: GRAY THERMOPLASTIC ELASTOMER • ROBOTICS AND PLANT AUTOMATION EQUIPMENT

RATINGS/ UL TYPE TC-ER - 90°C, 600V • MATERIAL HANDLING EQUIPMENT

CE / LOW VOLTAGE DIRECTIVE TRAYS - EXPOSED RUNS

CONDUCTOR COLOR CODE ELECTRICAL CHARACTERISTICS CONDUCTOR #1-#24: DK. BLUE W/WHITE NUMBER PRINTING

CONDUCTOR #25: GREEN W/YELLOW STRIPE

PRINT LEGEND: MOHAWK E163873 M56678 16 AWG (1.31 mm sq) 25 COND - UL 1277 TC-ER - 600V TFFN (UL) --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40049 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE)

MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA

(978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com

This document is the property of Mohawk. The information contained herein is considered proprietary and not to be

reproduced by any means without written consent of Mohawk.

Rev Description Date Init. K ADJUST DIAMETER & WEIGHT; ADD ROHS 05/02/07 JS

L CHG TEMPS, BEND RADIUS, PRINT LEGEND 08/20/07 VB M ADJ COND NOM OD, ADJ FINAL CABLE OD 08/28/07 VB N ADJUST BEND RADIUS 09/04/07 JS

Date: 01/15/96 Page 1 of 1

Part Number:

M56678 Orig: Review:

Page 41: Cable Guide

GENERAL PRODUCT SPECIFICATION Phone 800-316-8877 Fax 978-368-1275

www.jamesmonroewire.com

Description: Twenty-Five Conductor, 16 AWG, Tray Cable-ER PP Foam Tape and Overall TPE Jacket

Date: 9/2/2008

Cable Diagram

Jacket

Binder Insulated Conductor

Components Twenty-Five 16 AWG Insulated Conductors

Conductor: 16 AWG, 65/34 bare copper

Insulation: .016" nominal wall of PVC (See Color Code)

Nylon Jacket: .005" nominal wall of Clear Nylon .100"

Cable Construction

Cabling: Twenty-five conductors cabled together around solid PVC filler with contra-helical lays

Binder: Foam Propylene tape

Jacket: .083" nominal wall of Gray TPE .794" (.834" max)

Print JMWCC E73202 25/C 16 AWG (1.31 mm 2) TC-ER 90C DRY 75C WET 600V (UL) - - - LL41103 CSA AWM I/II A/B 90C 600V FT4 - - - ELECTRIVERT FLEX-LINK SERIES K40234 CE (with Sequential Footage Marks every 2 feet)

Color Code Conductors 1 thru 24:

Conductor 25: Yellow and numerically printed Green/Yellow ground

Requirements Temperature: 90°C

Voltage: 600V Approvals: UL Type TC-ER

CSA AWM, I/II, A/B CE - LVD RoHS Compliant

File:Public\JMWC_Ref\Spec\JMEVT40234-25C16-65str-TPE-TC.xls

Written By: RA 9/2/2008 Rev. 0 Initial Issue Revised By: Revised By: Revised By:

K40234 16 AWG / 25C

Page 42: Cable Guide

SHEATH: .005” (.13 mm) OF NYLON

TEMP. RANGE: -25°C TO +90°C CABLE

APPLICATIONS

• MACHINE TOOLS NOMINAL OD: .865” (21.97 mm)

• TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE LISTINGS: CSA AWM I/II A/B FT4 - 90°C, 600V

GROUND CONDUCTOR: GREEN W/YELLOW STRIPE

Cabling Excellence for Open Architecture

Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations.

SPECIFICATION 33 CONDUCTOR HEAVY DUTY FLEXIBLE POWER SUPPLY CABLE

K40218 16 AWG / 33C

JACKET

CONDUCTOR

INSULATION

BARRIER

CONSTRUCTION PHYSICAL CHARACTERISTICS

PRIMARIES: COND: 16 AWG (1.31 mm²) (65/34) BARE COPPER CABLE WEIGHT: 550 lbs/1000ft (818 kg/km)

INSULATION: .016” (.41 mm) OF 105°C PVC BENDING RADIUS: 8.6” (218 mm) MIN (10 x CABLE OD)

NOMINAL DIAMETER: .101” (2.57 mm) RECOMMENDED ASSEMBLY: 33 CONDUCTORS AND A FILLER CABLED

TOGETHER WITH CONTRA-HELICAL LAYS BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE,

25% OVERLAP • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING JACKET: GRAY FLAME RETARDANT TPE • ROBOTICS AND PLANT AUTOMATION EQUIPMENT

RATINGS/ UL TYPE TC-ER - 90°C, 600V • MATERIAL HANDLING EQUIPMENT

CE / LOW VOLTAGE DIRECTIVE TRAYS - EXPOSED RUNS

CONDUCTOR COLOR CODE ELECTRICAL CHARACTERISTICS CONDUCTOR #1-#32: DK. BLUE W/WHITE NUMBER PRINTING

CONDUCTOR DCR: 1.46 Ω/100m (4.44 Ω/Mft) MAX

PRINT LEGEND: MOHAWK E83542 M58766 - UL 1277 TC-ER - 600V TFFN (UL) 16 AWG (1.31 mm sq) 33 COND --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40218 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE)

MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA

(978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com

This document is the property of Mohawk. The information contained herein is considered proprietary and not to be

reproduced by any means without written consent of Mohawk.

Rev Description Date Init. A CHANGE JACKET COLOR TO LIGHT GRAY 09/06/06 VB

B ADD PART NUMBER; UPDATE PRINT & WEIGHT 09/11/06 JS C ADJ TEMPS, BEND RAD, PRINT, APPS; ADD ROHS 03/27/08 JS D ADJUST DIAMETERS, WGT, BEND RADIUS 03/28/08 JS

Date: 03/07/05 Page 1 of 1

Part Number:

M58766 Orig: Review:

Page 43: Cable Guide

POWER SUPPLY CABLE

NOMINAL DIAMETER: .099” (2.51 mm)

ASSEMBLY: 37 CONDUCTORS CABLED TOGETHER IN

TEMP. RANGE: -25°C TO +90°C

• STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING

• MACHINE TOOLS

• TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE NOMINAL OD: .925” (23.49 mm)

Cabling Excellence for Open Architecture

Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations.

SPECIFICATION 37 CONDUCTOR SHIELDED HEAVY DUTY

K40204 16 AWG / 37C

JACKET

BRAID

DRAIN

INSULATION

CONDUCTOR

BARRIER

CONSTRUCTION ELECTRICAL CHARACTERISTICS

PRIMARIES: CONDUCTOR: 16 AWG (1.31 mm²) CONDUCTOR DCR: 1.46 Ω/100m (4.44 Ω/Mft) MAX (65 STRANDS OF 34 AWG) BARE COPPER INSULATION: .016” (.41 mm) OF 105°C PVC SHEATH: .0045” (.11 mm) OF NYLON PHYSICAL CHARACTERISTICS

CABLE WEIGHT: 637 lbs/1000ft (948 kg/km)

CABLE BENDING RADIUS: 9.25” (235 mm) MIN (10 x CABLE OD)

CONTRA-HELICAL LAYS RECOMMENDED

BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, 25% OVERLAP

APPLICATIONS DRAIN WIRE: 18 AWG (16/30) TINNED COPPER

BRAID SHIELD: 34 AWG TINNED COPPER, 70% COVERAGE • NOT FOR CONTINUOUS FLEXING

JACKET: BLACK FLAME RETARDANT TPE • MATERIAL HANDLING EQUIPMENT

TRAYS - EXPOSED RUNS

RATINGS/ UL TYPE TC-ER - 90°C, 600V LISTINGS: CSA AWM I/II A/B FT4 - 90°C, 600V

CE / LOW VOLTAGE DIRECTIVE CONDUCTOR COLOR CODE CONDS #1 - #36: BLACK W/WHITE NUMBER PRINTING GROUND COND: GREEN W/YELLOW STRIPE

LEGEND: MOHAWK E163873 M58488 - UL 1277 TC-ER - 600V TFFN (UL) 16 AWG (1.31 mm sq) 37 COND SUN RES --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRIVERT FLEX-LINK SERIES K40204 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE)

MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA

(978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com

This document is the property of Mohawk. The information contained herein is considered proprietary and not to be

reproduced by any means without written consent of Mohawk.

Rev Description Date Init. C UPDATE TITLE, COND, ADD APPS 05/21/07 RA

D CHG TEMPS, PRINT LEGEND, ADDED ROHS 11/29/07 VB E MODIFIED ONE OF THE APPLICATIONS 12/05/07 VB F CHANGE FINAL OD 12/10/07 VB

Date: 03/01/04 Page 1 of 1

Part Number:

M58488 Orig: Review:

Page 44: Cable Guide

22 AWG Cable Specifications

Page 45: Cable Guide

NOMINAL DIAMETER: .050” (1.27 mm)

TEMP. RANGE: -20°C TO +105°C ASSEMBLY: 24 CONDUCTORS CABLED TOGETHER AROUND A

CONDUCTOR COLOR CODE

CONDUCTOR #24: GREEN W/YELLOW STRIPE RATINGS: NON-CSA

Cabling Excellence for Open Architecture

Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations.

SPECIFICATION 24 CONDUCTOR 22 AWG CABLE

POWER SUPPLY

K40182 22 AWG / 24C

JACKET

CONDUCTOR

INSULATION

BARRIER CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 22 AWG (.35 mm2) (7/30) TINNED COPPER CABLE WEIGHT: 108 lbs/1000ft (161 kg/km)

INSULATION: .010” (.25 mm) OF 80°C PVC BENDING RADIUS: 4.2” (107 mm) MIN (10 x CABLE OD)

CABLE RECOMMENDED

FILLER IN A LEFT HAND LAY BARRIER: OVERALL PAPER TAPE, 25% OVERLAP

JACKET: GRAY THERMOPLASTIC ELASTOMER NOMINAL OD: .415” (10.54 mm)

LISTING/ UL TYPE PLTC - 80C CONDUCTOR #1-#23: DK. BLUE W/WHITE NUMBER PRINTING

CE - LOW VOLTAGE DIRECTIVE ELECTRICAL CHARACTERISTICS

CONDUCTOR DCR: 5.74 Ω/100m (17.5 Ω/Mft) MAX

PRINT LEGEND: MOHAWK E M58122 22 AWG (.35 mm sq) 24 COND (UL) TYPE PLTC 80C --- --- K40182 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE)

MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA

(978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com

This document is the property of Mohawk. The information contained herein is considered proprietary and not to be

reproduced by any means without written consent of Mohawk.

Rev Description Date Init. B CHG PRINTTO INCLUDE mm sq, SFM, DATE CODE 10/09/02 JS

C UPDATE HDR/FTR, PRINT 12/15/05 JS D CHG TEMPS, BEND RADIUS, ADDED ROHS 11/15/07 VB E CHG FINAL OD, NO CSA LISTING 12/5/07 VB

Date: 06/06/01 Page 1 of 1

Part Number:

M58122 Orig: Review:

Page 46: Cable Guide

Communication / Shielded Cable Specifications

Page 47: Cable Guide

RATINGS: CSA AWM I/II A/B FT4 - 80°C, 300V

SHEATH: .003" (.076 mm) OF NYLON

ELECTRICAL CHARACTERISTICS

Cabling Excellence for Open Architecture

Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations.

SPECIFICATION 3 COND 20 AWG SHIELDED CABLE

K40228 20 AWG / 3C

Jacket Braid Shield

Conductor Drain Wire

Shield Tape

CONSTRUCTION PRIMARIES: COND: 20 AWG (.52 mm2) (19/32) TINNED COPPER

LISTING/ UL PLTC-ER 105°C, 300V

INSULATION: .010” (.25 mm) OF PVC CE - LOW VOLTAGE DIRECTIVE

NOMINAL DIAMETER: .065” (1.65 mm) COLORS: BLACK, RED, WHITE

CABLE CONDUCTOR DCR: 9.3 Ω/100m (28.3 Ω/Mft) MAX ASSEMBLY: 3 CONDUCTORS CABLED TOGETHER IN A

2.25" LEFT HAND LAY

SHIELD TAPE: OVERALL ALUMINUM/POLYESTER TAPE, 25% OVERLAP, 100% COVERAGE, ALUM SIDE OUT

DRAIN WIRE: 22 AWG (19/34) TINNED COPPER

BRAID: #36 AWG TINNED COPPER, 80% COV

JACKET: MATERIAL: THERMOPLASTIC ELASTOMER WALL THICKNESS: .045" (1.14 mm) NOMINAL OD: .255” +/- .025" (6.48 mm +/- .63 mm) COLOR: GRAY

PRINT LEGEND: MOHAWK E M58837 20 AWG (0.52 mm sq) 3 COND (UL) TYPE PLTC-ER SUN RES 105C --- LL CSA AWM I/II A/B 80C 300V FT4 --- ELECTRIFLEX K40228 CE (W/SEQUENTIAL FOOTAGE MARKS & DATE CODE)

MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA

(978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com

This document is the property of Mohawk. The information contained herein is considered proprietary and not to be

reproduced by any means without written consent of Mohawk.

Rev Description Date Init. A ADDED CSA LISTING 02/22/08 VB B REVISE PRINT; ADD PART NUMBER 05/02/08 JS C REVISE PRINT; ADD K # 05/09/08 JS

Date: 09/26/07 Page 1 of 1

Part Number:

M58837 Orig: Review:

Page 48: Cable Guide

Conductor

RATINGS: CSA AWM I/II A/B FT4 - 80°C, 300V

SHEATH: .003" (.076 mm) OF NYLON

4.0" LEFT HAND LAY

Cabling Excellence for Open Architecture

M. ohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations.

SPECIFICATION 2 PAIR 20 AWG SHIELDED CABLE

K40229 20 AWG / 2 PR

Jacket Braid Shield Filler

Drain Wire

Shield Tape

CONSTRUCTION PRIMARIES: COND: 20 AWG (.52 mm2) (19/32) TINNED COPPER

LISTING/ UL PLTC-ER 105°C, 300V

INSULATION: .010” (.25 mm) OF PVC CE - LOW VOLTAGE DIRECTIVE

NOMINAL DIAMETER: .065” (1.65 mm)

PAIR PAIR COLOR CODE ASSEMBLY: 2 PRIMARIES TWISTED IN A 2.0" LEFT HAND LAY PAIR #1: RED & BLACK

PAIR #2: WHITE & BLACK CABLE ASSEMBLY: 2 PAIRS CABLED WITH FILLERS TOGETHER IN A ELECTRICAL CHARACTERISTICS

CONDUCTOR DCR: 9.3 Ω/100m (28.3 Ω/Mft) MAX

SHIELD TAPE: OVERALL ALUMINUM/POLYESTER TAPE, 25% OVERLAP, 100% COVERAGE, ALUM SIDE OUT

DRAIN WIRE: 22 AWG (19/34) TINNED COPPER

BRAID: #36 AWG TINNED COPPER, 80% COV

JACKET: MATERIAL: THERMOPLASTIC ELASTOMER WALL THICKNESS: .050" (1.27 mm) NOMINAL OD: .325” +/- .025" (8.25 +/- .63 mm) COLOR: GRAY

PRINT LEGEND: MOHAWK E M58838 20 AWG (0.52 mm sq) 2PR (UL) TYPE PLTC-ER SUN RES 105C --- LL CSA AWM I/II A/B 80C 300V FT4 --- ELECTRIFLEX K40229 CE (W/SEQUENTIAL FOOTAGE MARKS & DATE CODE)

MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA

(978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com

This document is the property of Mohawk. The information contained herein is considered proprietary and not to be

reproduced by any means without written consent of Mohawk.

Rev Description Date Init. A ADDED CSA LISTING 02/22/08 VB

B REVISE PRINT; ADD PART NUMBER 05/02/08 JS C REVISE PRINT; ADD K # 05/09/08 JS

Date: 09/26/07 Page 1 of 1

Part Number:

M58838 Orig: Review:

Page 49: Cable Guide

RATINGS: CSA AWM I/II A/B FT4 - 80°C, 300V

Cabling Excellence for Open Architecture

Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations.

SPECIFICATION 3 PAIR 20 AWG SHIELDED CABLE

K40231 20 AWG / 3 PR

Jacket Braid Shield

Conductor Drain Wire

Shield Tape

CONSTRUCTION LISTING/ UL PLTC-ER 105°C, 300V

PRIMARIES: COND: 20 AWG (.52 mm2) (19/32) TINNED COPPER CE - LOW VOLTAGE DIRECTIVE INSULATION: .010” (.25 mm) OF PVC SHEATH: .003" (.076 mm) OF NYLON NOMINAL DIAMETER: .065” (1.65 mm)

PAIR PAIR COLOR CODE ASSEMBLY: 2 PRIMARIES TWISTED IN A 2.0" LEFT HAND LAY PAIR #1: RED & BLACK

PAIR #2: BLUE & BLACK CABLE PAIR #3: GREEN & BLACK ASSEMBLY: 3 PAIRS CABLED TOGETHER IN A 4.0" LEFT HAND

LAY ELECTRICAL CHARACTERISTICS

SHIELD TAPE: OVERALL ALUMINUM/POLYESTER TAPE, 25% CONDUCTOR DCR: 9.3 Ω/100m (28.3 Ω/Mft) MAX OVERLAP, 100% COVERAGE, ALUM SIDE OUT

DRAIN WIRE: 22 AWG (19/34) TINNED COPPER

BRAID: #36 AWG TINNED COPPER, 80% COV

JACKET: MATERIAL: THERMOPLASTIC ELASTOMER WALL THICKNESS: .050" (1.27 mm) NOMINAL OD: .340” +/- .025" (8.64 +/- .63 mm) COLOR: GRAY

PRINT LEGEND: MOHAWK E M58840 20 AWG (0.52 mm sq) 3PR (UL) TYPE PLTC-ER SUN RES 105C --- LL CSA AWM I/II A/B 80C 300V FT4 --- ELECTRIFLEX K40231 CE (W/SEQUENTIAL FOOTAGE MARKS & DATE CODE)

MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA

(978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com

This document is the property of Mohawk. The information contained herein is considered proprietary and not to be

reproduced by any means without written consent of Mohawk.

Rev Description Date Init. A REVISE PRINT; ADD PART NUMBER 05/02/08 JS

B REVISE PRINT; ADD K # 05/09/08 JS

Date: 02/26/08 Page 1 of 1

Part Number:

M58840 Orig: Review:

Page 50: Cable Guide

GENERAL PRODUCT SPECIFICATION Phone 800-316-8877 Fax 978-368-1275

www.jamesmonroewire.com

Description: Sixteen 20 AWG Twisted Pairs, Overall Foil Shield, Braid Shield and TPE Jacket

Date: 8/29/2008

Jac ket

Braid Shield Drain Wire Foil Shield

Twisted Pair

Components Conductors:

Insulation: 20 AWG, 10/30 bare copper .016" nominal wall of PVC (see color code) .069"

Pair Twist: Two 20 AWG insulated conductors twisted together .138" (major axis)

Cable Construction Cabling: Sixteen twisted pairs cable together

Foil Shield: Mylar-Aluminum tape, Aluminum side Out

Drain Wire: 22 AWG, 7/30 tinned copper

Braid Shield: 36 AWG tinned copper braid, 85% coverage

Jacket: .065" nominal wall of Gray TPE .686" (.720" max)

Print JMWCC E67179 16/PR 20 AWG (0.50 mm 2) 105C (UL) TYPE PLTC - - - LL41103 CSA AWM I/II A/B 105C 300V FT4 - - - ELECTRIVERT K40232 (with Sequential Footage Marks every 2 feet)

CE

Color Code 1. 2. 3. 4. 5. 6.

Black and Red Black and White Black and Green Black and Blue Black and Yellow Black and Brown

7. 8. 9.

10. 11. 12.

Black and Orange Red and White Red and Green Red and Blue Red and Yellow Red and Brown

13. 14. 15. 16.

Red and Orange Green and White Green and Blue Green and Yellow

Requirements Temperature: 105C Approvals: UL PLTC

CSA AWM CE - Low Voltage Directive RoHS Compliant

Voltage: 300V

1 of 1 File: public\\JMEVT40232-16PR20-10str-OS-OBS-PLTC-CSA-AWM.xls

Written By: RA 8/29/2008 Rev. 0 Initial Issue Revised By: Revised By: Revised By:

K40232 20 AWG / 16 PR

Page 51: Cable Guide

P3

NOMINAL DIAMETER: .059” (1.50 mm)

PAIR TEMP. RANGE: -50°C TO +80°C

IN A 3.25” LEFT HAND LAY SHIELD TAPE: OVERALL ALUMINUM/POLYESTER TAPE, PAIR #2: GREEN & YELLOW

ALUMINUM SIDE FACING OUT AGAINST BRAID

MAXIMUM OD: .335” (8.51 mm)

Cabling Excellence for Open Architecture

Mohawk reserves the right to change any specification in the interest of product enhancement.

SPECIFICATION 3 PAIR 22 AWG SHIELDED CABLE

K40161 22 AWG / 3 PR

Jacket Braid Shield Insulation

P2 Conductor Shield Tape

PVC Filler P1

CONSTRUCTION PHYSICAL CHARACTERISTICS

PRIMARIES: COND: 22 AWG (0.33 mm²) (41/38) BARE COPPER CABLE WEIGHT: 57 lbs/1000ft (85 kg/km) INSULATION: .015” (.38 mm) OF POLYPROPYLENE BENDING RADIUS: 3.1” (79 mm) MIN (10 x CABLE OD)

RECOMMENDED

ASSEMBLY: 2 PRIMARIES TWISTED TOGETHER IN A 1.75” LEFT HAND LAY

CABLE ASSEMBLY: 3 PAIRS CABLED TOGETHER WITH PVC FILLERS PAIR COLOR CODE

PAIR #1: WHITE & BROWN

25% OVERLAP, 100% COVERAGE PAIR #3: GRAY & PINK

BRAID: #36 AWG TINNED COPPER, 85% COV, 29° ANGLE

JACKET: VIOLET POLYURETHANE ELECTRICAL CHARACTERISTICS NOMINAL OD: .310” (7.87 mm) CONDUCTOR DCR: 5.32 Ω/100m (16.21 Ω/Mft) MAX

LISTING/ UL AWM STYLE 20233 - 80C, 300V RATINGS: CE - LOW VOLTAGE DIRECTIVE

PRINT LEGEND: MOHAWK E28558 M58015 AWM STYLE 20233 80C 300V - 22 AWG (0.33 mm sq) 3 PRS --- ELECTRI-FLEX K40161 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & YEAR/SHOP ORDER CODE)

MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA

(978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com

This document is the property of Mohawk. The information contained herein is considered proprietary and not to be

reproduced by any means without written consent of Mohawk.

Rev Description Date Init. A UPDATE FORMAT & PRINT 09/26/00 JL

B ADD UL FILE # TO PRINT LEGEND & P/N 10/13/00 JL C ADD mm sq TO PRINT; ADD SEQ FOOTAGE MARKS 06/03/03 VB D UPDATE HEADER/FOOTER, PRINT 03/04/05 JS

Date: 09/15/00 Page 1 of 1

Part Number:

M58015 Orig: Review:

Page 52: Cable Guide

P3

NOMINAL DIAMETER: .059” (1.50 mm)

PAIR TEMP. RANGE: -50°C TO +80°C

IN A 3.25” LEFT HAND LAY SHIELD TAPE: OVERALL ALUMINUM/POLYESTER TAPE, PAIR #2: GREEN & YELLOW

ALUMINUM SIDE FACING OUT AGAINST BRAID

MAXIMUM OD: .335” (8.51 mm)

Cabling Excellence for Open Architecture

Mohawk reserves the right to change any specification in the interest of product enhancement.

SPECIFICATION 3 PAIR 22 AWG SHIELDED CABLE

K40160 22 AWG / 3 PR

Jacket Braid Shield Insulation

P2 Conductor Shield Tape

PVC Filler P1

CONSTRUCTION PHYSICAL CHARACTERISTICS PRIMARIES: COND: 22 AWG (0.33 mm2) (41/38) BARE COPPER CABLE WEIGHT: 57 lbs/1000ft (85 kg/km)

INSULATION: .015” (.38 mm) OF POLYPROPYLENE BENDING RADIUS: 3.1” (79 mm) MIN (10 x CABLE OD) RECOMMENDED

ASSEMBLY: 2 PRIMARIES TWISTED TOGETHER IN A 1.75” LEFT

HAND LAY CABLE ASSEMBLY: 3 PAIRS CABLED TOGETHER WITH PVC FILLERS PAIR COLOR CODE

PAIR #1: WHITE & BROWN

25% OVERLAP, 100% COVERAGE PAIR #3: GRAY & PINK

BRAID: #36 AWG TINNED COPPER, 85% COV, 29° ANGLE

JACKET: GRAY POLYURETHANE ELECTRICAL CHARACTERISTICS NOMINAL OD: .310” (7.87 mm) CONDUCTOR DCR: 5.32 Ω/100m (16.21 Ω/Mft) MAX

LISTING/ UL AWM STYLE 20233 - 80C, 300V RATINGS: CE - LOW VOLTAGE DIRECTIVE

PRINT LEGEND: MOHAWK E28558 M58014 AWM STYLE 20233 80C 300V - 22 AWG (0.33 mm sq) 3 PRS --- ELECTRI-FLEX K40160 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & YEAR/SHOP ORDER CODE)

MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA

(978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com

This document is the property of Mohawk. The information contained herein is considered proprietary and not to be

reproduced by any means without written consent of Mohawk.

Rev Description Date Init. B ADJUST K # 10/03/00 WL

C ADD UL FILE # TO PRINT LEGEND & P/N 10/13/00 JL D ADD mm sq, SFM & DC TO PRINT 06/07/02 JS E UPDATE HEADER/FOOTER, PRINT 03/04/05 JS

Date: 09/15/00 Page 1 of 1

Part Number:

M58014 Orig: Review:

Page 53: Cable Guide

CONDUCTOR: 22 AWG (.35 mm2) (7/30) PRIMARIES:

NOMINAL DIAMETER: .050”

ASSEMBLY: 2 PRIMARIES TWISTED IN A 1.5” LEFT HAND LAY

P7 BLACK & ORANGE ASSEMBLY: 17 PAIRS CABLED WITH A 6” LEFT HAND LAY

NOMINAL OD: .560" (14.22 mm)

Cabling Excellence for Open Architecture

Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations.

SPECIFICATION 17 PAIR SHIELDED CABLE

K40036 22 AWG / 17 PR

CONSTRUCTION COLOR CODE

P1 BLACK & RED

BARE COPPER P2 BLACK & WHITE INSULATION: .010” OF SEMI-RIGID PVC P3 BLACK & GREEN

P4 BLACK & BLUE PAIR P5 BLACK & YELLOW

P6 BLACK & BROWN CABLE

(CORE: P1-P5, 1ST LAYER: P6-P17) P8 RED & WHITE

BARRIER: OVERALL FOAMED POLYPROPYLENE TAPE, P9 RED & GREEN 25% OVERLAP P10 RED & BLUE

DRAIN WIRE: 22 AWG (7/30) TINNED COPPER P11 RED & YELLOW

BRAID SHIELD: 34 AWG TINNED COPPER, 44° ANGLE P12 RED & BROWN 91% COVERAGE P13 RED & ORANGE

JACKET: COMPOUND: THERMOPLASTIC ELASTOMER P14 GREEN & WHITE NOMINAL WALL: .055" (1.40 mm) P15 GREEN & BLUE

COLOR: BLACK P16 GREEN & YELLOW

LISTING/ UL TYPE PLTC - 90C P17 GREEN & BROWN

RATINGS: CSA - NONE

LEGEND: MOHAWK E39829 M57325 22 AWG (.35 mm sq) 17PR (UL) TYPE PLTC 90C --- FT4 --- K40036 CE

ELECTRICAL CHARACTERISTICS

CONDUCTOR DCR: 5.54 Ω/100m (16.9 Ω/Mft) MAX

PHYSICAL CHARACTERISTICS

CABLE WEIGHT: 215 lbs/1000ft (320 kg/km)

MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA

(978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com

This document is the property of Mohawk. The information contained herein is considered proprietary and not to be

reproduced by any means without written consent of Mohawk.

Rev Description Date Init. A ADD UL TO LISTING 04/27/98 VB B UPDATE FORMAT & PRINT 11/30/05 JS C CHG JKT DIA & AWM TO PLTC; UPDATE PRINT, WT 03/22/07 JS D CHG BRD TO #34; ADJ JKT DIA; DEL CSA; ADD ROHS 12/28/07 JS

Date: 04/09/98 Page 1 of 1

Part Number:

M57325 Orig: Review:

Page 54: Cable Guide

PRIMARIES: CONDUCTOR: 22 AWG (7/30) BARE COPPER

P7 BLACK & ORANGE LAY OVERALL FOAMED POLYPROPYLENE TAPE, BARRIER:

BRAID SHIELD: 32 AWG TINNED COPPER, 90% COVERAGE

JACKET: COMPOUND: THERMOPLASTIC ELASTOMER

CE - LOW VOLTAGE DIRECTIVE

LEGEND: MOHAWK E M58506 22 AWG (.35 mm sq)

P28 ORANGE & YELLOW

CABLE WEIGHT: 383 lbs/1000ft (569 kg/km)

Cabling Excellence for Open Architecture

Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations.

SPECIFICATION 37 PAIR SHIELDED CABLE

K40205 22 AWG / 37 PR

CONSTRUCTION COLOR CODE

P1 BLACK & RED

INSULATION: .010” OF SEMI-RIGID PVC P2 BLACK & WHITE NOMINAL DIAMETER: .050” P3 BLACK & GREEN

PAIR P4 BLACK & BLUE ASSEMBLY: 2 PRIMARIES TWISTED IN A 1.5” LEFT HAND LAY P5 BLACK & YELLOW

CABLE P6 BLACK & BROWN ASSEMBLY: 37 PAIRS CABLED WITH AN 8.25” LEFT HAND

P8 RED & WHITE

25% OVERLAP P9 RED & GREEN

DRAIN WIRE: 22 AWG (7/30) TINNED COPPER P10 RED & BLUE P11 RED & YELLOW P12 RED & BROWN P13 RED & ORANGE

NOMINAL OD: .774" (19.66 mm) P14 GREEN & WHITE COLOR: BLACK P15 GREEN & BLUE

RATINGS: 80°C, 300V P16 GREEN & YELLOW

LISTING/ UL TYPE PLTC - 80C P17 GREEN & BROWN RATINGS: NON CSA P18 GREEN & ORANGE

P19 WHITE & BLUE P20 WHITE & YELLOW

37PR (UL) TYPE PLTC 80C --- K40205 CE P21 WHITE & BROWN (WITH SEQUENTIAL FOOTAGE MARKERS P22 WHITE & ORANGE EVERY 2 FEET & DATE CODE) P23 BLUE & YELLOW

P24 BLUE & BROWN P25 BLUE & ORANGE P26 BROWN & YELLOW

ELECTRICAL CHARACTERISTICS P27 BROWN & ORANGE

CONDUCTOR DCR: 5.54 Ω/100m (16.9 Ω/Mft) MAX P29 VIOLET & ORANGE

P30 VIOLET & RED P31 VIOLET & WHITE

PHYSICAL CHARACTERISTICS P32 VIOLET & DK. GREEN

P33 VIOLET & LT. BLUE P34 VIOLET & YELLOW P35 VIOLET & BROWN P36 VIOLET & BLACK P37 GRAY & WHITE

MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA

(978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com

This document is the property of Mohawk. The information contained herein is considered proprietary and not to be

reproduced by any means without written consent of Mohawk.

Rev Description Date Init. A REVISED FINAL OD, CHG AWG ON BRAID, NON CSA 12/06/07 VB

Date: 11/29/07 Page 1 of 1

Part Number:

M58506 Orig: Review:

Page 55: Cable Guide

Hybrid / Composite Cable Specifications

Page 56: Cable Guide

WALL THICKNESS: .050" (1.27 mm)

RATINGS: CSA AWM I/II A/B FT4 - 80°C, 300V ASSEMBLY: 2 PRIMARIES TWISTED IN A LEFT HAND LAY

NOMINAL DIAMETER: .085” (2.15 mm)

PAIR PAIR #2: WHITE & BLACK (22 AWG)

PAIR #4: WHITE & BROWN (16 AWG)

ELECTRICAL CHARACTERISTICS

LAY

Cabling Excellence for Open Architecture

Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations.

SPECIFICATION 1 PAIR 16 AWG & 3 PAIR 22 AWG SHIELDED CABLE

K40230 16AWG/1PR 22AWG/3PR

Jacket Braid Shield

Component A Conductor Component B Shielded Pair Drain Wire

Shield Tape

CONSTRUCTION

COMPONENT A (TOTAL THREE) JACKET: MATERIAL: THERMOPLASTIC ELASTOMER

PRIMARIES: COND: 22 AWG (.38 mm2) (19/34) TINNED COPPER NOMINAL OD: .340” (8.63 mm) INSULATION: .010” (.25 mm) OF PVC COLOR: GRAY SHEATH: .003" (.076 mm) OF NYLON NOMINAL DIAMETER: .056” (1.42 mm)

PAIR LISTING/ UL PLTC-ER 105°C, 300V

CE - LOW VOLTAGE DIRECTIVE COMPONENT B (TOTAL ONE)

PRIMARIES: COND: 16 AWG (1.32 mm2) (26/30) TINNED COPPER

INSULATION: .010” (.25 mm) OF PVC SHEATH: .003" (.076 mm) OF NYLON PAIR COLOR CODE

PAIR #1: RED & BLACK (22 AWG)

ASSEMBLY: 2 PRIMARIES TWISTED IN A 2.5" LEFT HAND LAY PAIR #3: GREEN & BLACK (22 AWG)

DRAIN WIRE: 22 AWG (19/34) TINNED COPPER

SHIELD TAPE: OVERALL ALUMINUM/POLYESTER TAPE, 25% OVERLAP, 100% COVERAGE, ALUM SIDE IN

CABLE CONDUCTOR DCR: 15.0 Ω/100m (45.7 Ω/Mft) MAX 22 AWG

ASSEMBLY: 4 PAIRS CABLED TOGETHER IN A 4.5" LEFT HAND CONDUCTOR DCR: 4.34 Ω/100m (13.2 Ω/Mft) MAX 16 AWG

SHIELD TAPE: OVERALL ALUMINUM/POLYESTER TAPE, 25% OVERLAP, 100% COVERAGE, ALUM SIDE OUT

DRAIN WIRE: 22 AWG (19/34) TINNED COPPER

BRAID: #36 AWG TINNED COPPER, 80% COV

PRINT LEGEND: MOHAWK E M58839 22 AWG (0.38 mm sq) 3PR & 16 AWG (1.32 mm sq) 1PR (UL) TYPE PLTC-ER SUN RES 105C --- LL CSA AWM I/II A/B 80C 300V FT4 --- ELECTRIFLEX K40230 CE (W/SEQUENTIAL FOOTAGE MARKS & DATE CODE)

MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA

(978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com

This document is the property of Mohawk. The information contained herein is considered proprietary and not to be

reproduced by any means without written consent of Mohawk.

Rev Description Date Init. A ADDED CSA LISTING 02/22/08 VB

B REVISE PRINT; ADD PART NUMBER 05/02/08 JS C REVISE PRINT; ADD K # 05/09/08 JS

Date: 09/26/07 Page 1 of 1

Part Number:

M58839 Orig: Review:

Page 57: Cable Guide

COMPOSITE CABLE

WITH FILLERS IN A 5.75” LEFT HAND LAY

OVERALL FOAMED POLYPROPYLENE, BARRIER:

COPPER

COPPER CONDUCTOR DCR:

CONDUCTOR DCR:

2.82 Ω/1000’ (COMPONENT A)

6.59 Ω/1000’ (COMPONENT B) SHEATH: .0045” (.11 mm) WALL OF NYLON

P1 BLUE #5 & #6

APPLICATIONS SURFACE FACING OUT AGAINST DRAIN

• ROBOTICS AND PLANT AUTOMATION EQUIPMENT

20° ANGLE • MATERIAL HANDLING EQUIPMENT

Cabling Excellence for Open Architecture

Mohawk reserves the right to change any specification in the interest of product enhancement. This cable complies with the EU-RoHS directive 2002/95/EC (restrictions on hazardous substances) regulations.

SPECIFICATION 4 COND #14 AWG, 2 PAIR #18 AWG,

K40162 14AWG/4C | 18AWG/2PR

Jacket

Pair Shield Conductor Insulation Barrier Filler Overall Shield

FINAL CABLE CONSTRUCTION ASSEMBLY: THE ABOVE COMPONENTS ARE CABLED

COMPONENT A (4 TOTAL) PRIMARIES: CONDUCTOR: #14 AWG (2.11 mm²) (105/34) BARE 25% OVERLAP

INSULATION: .016” (.41 mm) WALL OF 105°C PVC SHIELD: #34 AWG TINNED COPPER BRAID, 86% COV. SHEATH: .005” (.13 mm) WALL OF NYLON JACKET: MATERIAL: ORANGE THERMOPLASTIC ELASTOMER NOMINAL DIAMETER: .116” (2.95 mm) NOMINAL WALL: .062” (1.57 mm)

COLOR CODE: 3/C BLACK & NUMBERED #1 - #3 IN WHITE INK DIAMETER: .621” (15.77 mm) 1/C GREEN WITH YELLOW STRIPE LISTING/ UL TYPE TC-ER - 90°C, 600V

RATINGS: CSA AWM I/II A/B FT4 - 90°C, 600V CE - LOW VOLTAGE DIRECTIVE

COMPONENT B (2 TOTAL) PRIMARIES: CONDUCTOR: #18 AWG (0.82 mm²) (41/34) BARE ELECTRICAL CHARACTERISTICS

INSULATION: .016” (.41 mm) WALL OF 105°C PVC

NOMINAL DIAMETER: .088” (2.23 mm)

COLOR CODE: BLUE & NUMBERED #5 - #8 PHYSICAL CHARACTERISTICS PAIR TEMP. RATING: -25° to +90°C ASSEMBLY: 2 PRIMARIES TWISTED IN A 2.5” LEFT HAND LAY VOLTAGE RATING: 600 VOLTS

P2 BLUE #7 & #8 CABLE WEIGHT: 273 lbs/M’ (406 kg/km)

SHIELD: OVERALL ALUMINUM/POLYESTER TAPE, BENDING RADIUS: 6.2” (157 mm) MIN (10 x CABLE OD) 25% OVERLAP, 100% COVERAGE, ALUMINIZED

DRAIN: 20 AWG (10/30) TINNED COPPER • STATIONARY/CABLE TRAY AND SOME MINIMAL FLEXING

SHIELD: 36 AWG TINNED COPPER BRAID, 86% COVERAGE, • MACHINE TOOLS

ISOLATION: OVERALL POLYESTER TAPE, 50% OVERLAP • TC-ER COMPLIANT FOR CABLES EXTENDED FROM CABLE

TRAYS - EXPOSED RUNS

PRINT: MOHAWK E163873 M57997 -UL 1277 TC-ER - 600V (UL) 14 AWG (2.11 mm sq) 4 COND THHN - 18 AWG (0.82 mm sq) 2 PRS TFFN --- LL49185 CSA AWM I/II A/B 90C 600V FT4 --- ELECTRI-FLEX K40162 CE (WITH SEQUENTIAL FOOTAGE MARKERS EVERY 2 FEET & DATE CODE)

MOHAWK 9 Mohawk Drive Leominster, MA 01453 USA

(978) 537-9961 Fax: (978) 537-4358 (800) 422-9961 www.mohawk-cable.com

This document is the property of Mohawk. The information contained herein is considered proprietary and not to be

reproduced by any means without written consent of Mohawk.

Rev Description Date Init. E DELETE SEQ FOOTAGE MARKS & DATE CODE 12/10/03 JS F UPDATE HEADER/FOOTER, PRINT & LISTINGS 05/02/05 JS G UPDATE CSA TEMP, TEMP RATING, PRINT 05/31/06 JS H ADJ TEMP; ADD APPS, BEND, SQ FT/CODE, ROHS 11/14/07 JS

Date: 09/18/00 Page 1 of 1

Part Number:

M57997 Orig: Review: