William Fisher Architecture, Inc. 603 Front Street, Santa Cruz, California 95060 831 246 - 0117 bill@modern - architecture.com modern - architecture.com Licensed Architect William Fisher C−11008 10/31/19 RENEWS ON A I N O F I L A R C COPYRIGHT 2019, WILLIAM FISHER ARCHITECTURE, INC. Date Printed: 10/2/2019 11:29:52 AM Cabrillo College A0.0 Cabrillo College Room 356, Building 350 2600 Soquel Ave. Aptos, CA 95003 Issue Date General Notes and Project Information DON'T SCALE THE DRAWINGS. STUDY THE CONTRACT DOCUMENTS AND THE FIELD CONDITIONS BEFORE BIDDING OR DOING WORK ON THIS PROJECT. IMMEDIATELY REPORT TO THE ARCHITECT ANY ERRORS, OMISSIONS, OR UNCLEAR DIRECTIONS. THE ARCHITECT WILL EVALUATE THE PROBLEM AND MAKE A WRITTEN INTERPRETATION. NOTIFY THE ARCHITECT IMMEDIATELY OF ANY DEVIATIONS OR VARIATIONS FROM THE DRAWINGS OR SPECIFICATIONS SHOWN HEREIN. DIMENSIONS MARKED "CLEAR" SHALL BE MAINTAINED AND SHALL ALLOW FOR THICKNESS OF FINISH MATERIALS. DIMENSIONS ARE TAKEN FROM FACE OF FINISH (FOF), OR FROM CENTER LINES AS INDICATED. THE GENERAL CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE PROJECT. THE ARCHITECT MUST BE NOTIFIED IMMEDIATELY OF ANY DEVIATIONS OR VARIATIONS FROM THE DRAWINGS OR SPECIFICATIONS SHOWN HEREIN. "ALIGN" MEANS TO LOCATE FINISHED FACES IN SAME PLANE. "APPROVED" MEANS, UNLESS INDICATED OTHERWISE BY THE ARCHITECT, APPROVED IN WRITING BY THE ARCHITECT. "AS DIRECTED" OR "AS INDICATED" MEANS AS DESCRIBED EITHER VERBALLY OR IN WRITING BY THE ARCHITECT. "AS INDICATED" NORMALLY REFERS TO AN ITEM EXPLAINED IN THE CONTRACT. "THE CONTRACTOR" REFERS TO THE GENERAL CONTRACTOR, NOT HIS SUBCONTRACTORS. "PROVIDE" MEANS THAT THE CONTRACTOR SHALL FURNISH AND INSTALL. "UNLESS NOTED OTHERWISE", "UNO", OR "UNLESS INDICATED OTHERWISE" MEANS THAT THE ITEM DESCRIBED IS TYPICAL AS SHOWN EXCEPT AS WHERE SPECIFICALLY CALLED OUT AS DIFFERENT. "VERIFY" MEANS, UNLESS INDICATED OTHERWISE BY THE ARCHITECT, TO OBTAIN WRITTEN VERIFICATION OF THE ITEM OR METHOD INDICATED FROM THE ARCHITECT. THIS VERIFICATION MIGHT INCLUDE ELABORATION OR EXPLANATION BY THE ARCHITECT REQUIRING A MORE COMPLEX CONSTRUCTION SOLUTION THAN MIGHT BE ASSUMED BY READING THE DRAWING WITHOUT THE VERIFICATION, THEREFORE PLEASE MAKE VERIFICATIONS AS EARLY AS POSSIBLE BEFORE BIDDING THE WORK. APPROVED SHOP DRAWINGS DO NOT CONSTITUTE VERIFICATION. ANY ERROR, OMISSION, OR OTHER CONFLICT BETWEEN THESE DOCUMENTS MUST BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR HIS RESOLUTION AS SOON AS IT IS DISCOVERED. INFORM THE ARCHITECT IMMEDIATELY IF THE DRAWINGS, SPECIFICATIONS, OR OTHER CONSTRUCTION DOCUMENTS DON'T SEEM TO COMPLY WITH CURRENT APPLICABLE LAWS, CODES, OR REGULATIONS. U.N.O., APPLY, INSTALL, CONNECT, ERECT, CLEAN, AND CONDITION PRODUCTS PER THEIR MANUFACTURER'S CURRENT WRITTEN INSTRUCTIONS. VERIFY WITH MANUFACTURERS THEIR EQUIPMENT REQUIREMENTS (FOR INSTANCE, STRUCTURAL BLOCKING OR SUPPORT, ELECTRICAL OR MECHANICAL REQUIREMENTS, ETC.). OBTAIN EQUIPMENT SPECIFICATIONS FROM MANUFACTURER(S) TO HELP ENSURE PROPER FIT AND OPERATION. SURVEY FIELD CONDITIONS AND VERIFY FEASIBILITY OF INDICATED WORK, FOR INSTANCE LOCATIONS OF OUTLETS IN RELATION TO STRUCTURAL ELEMENTS. COVER HVAC DUCTS AIRTIGHT DURING CONSTRUCTION All work shall comply with 2016 California Building Code (Building Code), , 2016 California Electrical Code (Electrical Code), 2016 California Mechanical Code (Mechanical Code), 2016 California Plumbing Code (Plumbing Code), 2016 California Energy Code (Energy Code), 2016 California Fire Code (Fire Code), 2016 California Green Code (Green Code). CABRILLO COLLEGE ROOM 356 (REMODEL) 350 BUILDING PROJECT INFORMATION PROJECT DESCRIPTION GENERAL NOTES DIRECTIONS From Hwy 1 S, take Park Ave exit, turn left on Park Ave, turn right on Soquel Dr., site is on the left. From Hwy 1 N, take Park Ave exit, turn right on Park Ave, turn right on Soquel Dr., site is on the left. New Brighton State Beach Park Ave S o quel Dr . C abrillo C ollege Dr. P e ri mete r Rd . C a br i l l o Col lege SITE H W Y 1 N Site Address: 6500 Soquel Drive, Aptos, CA 95003, Building 350 APN: 03726103 Zoning: PF Construction Type: 1 Hour Construction Non - sprinklered CONTACT INFORMATION CLIENT Cabrillo College Contact: Mary Talpas Phone: (831) 477 - 5288 Email: [email protected]ARCHITECT William FIsher Architecture, Inc. Contact: Brian Lawler blawler@modern - architecture.com (650) 392 - 9233 Remodel of existing room 356 and HVAC system upgrade. Reconfigure space within existing shell for new electrical layout and addition of concrete equipment pad at exterior of building for new HVAC equipment. SCOPE OF SERVICES Base Responsibilities : Demolish, remove, replace and configure existing space as shown on plans. DESIGN CRITERIA FURTHER QUESTIONS During bidding process please direct all questions or requests for additional detailing to Cabrillo College Purchasing Department: [email protected]Sheet List A0.0 General Notes and Project Information A2.0 Floor Plans A3.1 Details E01 Electrical Symbols, Notes E10 Electrical Floor Plans - Demo E20 Electrical Power Plan E30 Electrical Lighting Plan E40 Electrical Low Voltage/ Signal Plan E50 Electrical Specifications M0.1 Mechanical Legends, Notes and Schedules M1.1 Mechanical Demolition Floor and Attic Plans M2.1 Mechanical New Work Plan M3.1 Mechanical Details P0.1 Plumbing Legend, Notes, Schedules and Details P1.1 Plumbing Demolition and New Work Plans Revision Schedule Rev. No. Date Room 356 Staging Area Contact Mary Talpas for specific direction on staging and contractor parking areas.
14
Embed
C−11008 CABRILLO COLLEGE ROOM 356 (REMODEL) 350 … · ROOM 356 (REMODEL) 350 BUILDING GENERAL NOTES PROJECT DESCRIPTION PROJECT INFORMATION DIRECTIONS From Hwy 1 S, take Park Ave
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Willi
am
Fis
her A
rc
hit
ectu
re, In
c.
603 F
ront
Str
eet,
Santa
Cru
z, C
alif
orn
ia 9
5060
831 2
46-0
117 b
ill@
modern
-arc
hitectu
re.c
om
modern
-arc
hitectu
re.c
om
Licensed
Architect
William Fisher
C−11008
10/31/19RENEWS ON
AINOFIL
AR
C
COPYRIGHT 2019, WILLIAM FISHER ARCHITECTURE, INC.
Date Printed:10/2/2019 11:29:52 AM
Cabrillo College
A0.0
Ca
bri
llo C
olle
ge
Ro
om
35
6, B
uild
ing
350
260
0 S
oq
ue
l A
ve
.A
pto
s,
CA
95
003
Issue Date
Gen
era
l N
ote
s a
nd
Pro
ject
Info
rmatio
n
DON'T SCALE THE DRAWINGS.
STUDY THE CONTRACT DOCUMENTS AND THE FIELD CONDITIONS BEFORE BIDDING OR DOING WORK ON THIS PROJECT. IMMEDIATELY REPORT TO THE ARCHITECT ANY ERRORS, OMISSIONS, OR UNCLEAR DIRECTIONS. THE ARCHITECT WILL EVALUATE THE PROBLEM AND MAKE A WRITTEN INTERPRETATION.
NOTIFY THE ARCHITECT IMMEDIATELY OF ANY DEVIATIONS OR VARIATIONS FROM THE DRAWINGS OR SPECIFICATIONS SHOWN HEREIN.
DIMENSIONS MARKED "CLEAR" SHALL BE MAINTAINED AND SHALL ALLOW FOR THICKNESS OF FINISH MATERIALS.
DIMENSIONS ARE TAKEN FROM FACE OF FINISH (FOF), OR FROM CENTER LINES AS INDICATED.
THE GENERAL CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE PROJECT. THE ARCHITECT MUST BE NOTIFIED IMMEDIATELY OF ANY DEVIATIONS OR VARIATIONS FROM THE DRAWINGS OR SPECIFICATIONS SHOWN HEREIN.
"ALIGN" MEANS TO LOCATE FINISHED FACES IN SAME PLANE.
"APPROVED" MEANS, UNLESS INDICATED OTHERWISE BY THE ARCHITECT, APPROVED IN WRITING BY THE ARCHITECT.
"AS DIRECTED" OR "AS INDICATED" MEANS AS DESCRIBED EITHER VERBALLY OR IN WRITING BY THE ARCHITECT. "AS INDICATED" NORMALLY REFERS TO AN ITEM EXPLAINED IN THE CONTRACT.
"THE CONTRACTOR" REFERS TO THE GENERAL CONTRACTOR, NOT HIS SUBCONTRACTORS.
"PROVIDE" MEANS THAT THE CONTRACTOR SHALL FURNISH AND INSTALL.
"UNLESS NOTED OTHERWISE", "UNO", OR "UNLESS INDICATED OTHERWISE" MEANS THAT THE ITEM DESCRIBED IS TYPICAL AS SHOWN EXCEPT AS WHERE SPECIFICALLY CALLED OUT AS DIFFERENT.
"VERIFY" MEANS, UNLESS INDICATED OTHERWISE BY THE ARCHITECT, TO OBTAIN WRITTEN VERIFICATION OF THE ITEM OR METHOD INDICATED FROM THE ARCHITECT. THIS VERIFICATION MIGHT INCLUDE ELABORATION OR EXPLANATION BY THE ARCHITECT REQUIRING A MORE COMPLEX CONSTRUCTION SOLUTION THAN MIGHT BE ASSUMED BY READING THE DRAWING WITHOUT THE VERIFICATION, THEREFORE PLEASE MAKE VERIFICATIONS AS EARLY AS POSSIBLE BEFORE BIDDING THE WORK. APPROVED SHOP DRAWINGS DO NOT CONSTITUTE VERIFICATION.
ANY ERROR, OMISSION, OR OTHER CONFLICT BETWEEN THESE DOCUMENTS MUST BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR HIS RESOLUTION AS SOON AS IT IS DISCOVERED.
INFORM THE ARCHITECT IMMEDIATELY IF THE DRAWINGS, SPECIFICATIONS, OR OTHER CONSTRUCTION DOCUMENTS DON'T SEEM TO COMPLY WITH CURRENT APPLICABLE LAWS, CODES, OR REGULATIONS.
U.N.O., APPLY, INSTALL, CONNECT, ERECT, CLEAN, AND CONDITION PRODUCTS PER THEIR MANUFACTURER'S CURRENT WRITTEN INSTRUCTIONS.
VERIFY WITH MANUFACTURERS THEIR EQUIPMENT REQUIREMENTS (FOR INSTANCE, STRUCTURAL BLOCKING OR SUPPORT, ELECTRICAL OR MECHANICAL REQUIREMENTS, ETC.). OBTAIN EQUIPMENT SPECIFICATIONS FROM MANUFACTURER(S) TO HELP ENSURE PROPER FIT AND OPERATION.
SURVEY FIELD CONDITIONS AND VERIFY FEASIBILITY OF INDICATED WORK, FOR INSTANCE LOCATIONS OF OUTLETS IN RELATION TO STRUCTURAL ELEMENTS.
COVER HVAC DUCTS AIRTIGHT DURING CONSTRUCTION
All work shall comply with 2016 California Building Code (Building Code), , 2016 California Electrical Code (Electrical Code), 2016 California Mechanical Code (Mechanical Code), 2016 California Plumbing Code (Plumbing Code), 2016 California Energy Code (Energy Code), 2016 California Fire Code (Fire Code), 2016 California Green Code (Green Code).
Remodel of existing room 356 and HVAC system upgrade. Reconfigure space within existing shell for new electrical layout and addition of concrete equipment pad at exterior of building for new HVAC equipment.
SCOPE OF SERVICES
Base Responsibilities: Demolish, remove, replace and configure existing space as shown on plans.
DESIGN CRITERIA
FURTHER QUESTIONS
During bidding process please direct all questions or requests for additional detailing to Cabrillo College Purchasing Department: [email protected]
Sheet List
A0.0 General Notes and Project Information
A2.0 Floor Plans
A3.1 Details
E01 Electrical Symbols, Notes
E10 Electrical Floor Plans - Demo
E20 Electrical Power Plan
E30 Electrical Lighting Plan
E40 Electrical Low Voltage/ Signal Plan
E50 Electrical Specifications
M0.1 Mechanical Legends, Notes and Schedules
M1.1 Mechanical Demolition Floor and Attic Plans
M2.1 Mechanical New Work Plan
M3.1 Mechanical Details
P0.1 Plumbing Legend, Notes, Schedules and Details
P1.1 Plumbing Demolition and New Work Plans
Revision Schedule
Rev. No. Date
Room 356
Staging Area
Contact Mary Talpas for specific direction on staging and contractor parking areas.
"a" INDICATES CONTROLLING SWITCH, "10" INDICATES CIRCUIT#.
AutoCAD SHX Text
SWITCH, W/ INTEGRATED TIMER FOR TIMED OPERATION
AutoCAD SHX Text
FL
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
H
AutoCAD SHX Text
2
AutoCAD SHX Text
1
AutoCAD SHX Text
OCCUPANCY SENSOR: WATTSTOPPER #W-2000H
AutoCAD SHX Text
OCCUPANCY SENSOR: WATTSTOPPER #DT-355-U
AutoCAD SHX Text
OCCUPANCY SENSOR: WATTSTOPPER #W-1000A
AutoCAD SHX Text
OCCUPANCY SENSOR: WATTSTOPPER #W-500A
AutoCAD SHX Text
5
AutoCAD SHX Text
PP
AutoCAD SHX Text
OCCUPANCY SENSOR POWER PACK:-WATTSTOPPER
AutoCAD SHX Text
TO
AutoCAD SHX Text
S
AutoCAD SHX Text
OS
AutoCAD SHX Text
S
AutoCAD SHX Text
EXIT SIGN, WIRED CONSTANT HOT, WITH BATTERY BACK-UP. SHADED QUADRANT INDICATES FACING DIRECTION. ARROW ON FACE IF NOTED. COMBINATION EXIT SIGN AND EGRESS LIGHT IF NOTED ON FIXTURE SCHEDULE.
AutoCAD SHX Text
OS1
AutoCAD SHX Text
S
AutoCAD SHX Text
OCCUPANCY SENSOR SWITCH: WALL MOUNTED PIR DUAL RELAY: WATTSTOPPER #WI-300A
AutoCAD SHX Text
OCCUPANCY SENSOR SWITCH: WALL MOUNTED PIR SINGLE RELAY WATTSTOPPER #WI-200
AutoCAD SHX Text
NEW 2X2 LAY-IN OR SURFACE LIGHT FIXTURE. SEE FIXTURE SCHEDULE.
AutoCAD SHX Text
SYMBOL LEGEND-LIGHTING-COMMERCIAL
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
SYMBOL
AutoCAD SHX Text
SWITCH, SINGLE GANG, +48" FINISH FLOOR TO CENTER
AutoCAD SHX Text
CAN LIGHT FIXTURE, CEILING MOUNTED, RECESSED
AutoCAD SHX Text
LIGHT FIXTURE, WALL MOUNTED, SCONCE
AutoCAD SHX Text
EMERGENCY FLOOD LIGHT, WIRED CONSTANT HOT
AutoCAD SHX Text
NEW 2X4 LED LAY-IN LIGHT FIXTURE. SEE FIXTURE SCHEDULE.
AutoCAD SHX Text
W/ BATTERY BACK-UP
AutoCAD SHX Text
NEW SURFACE STRIP LIGHT FIXTURE. SEE FIXTURE SCHEDULE.
AutoCAD SHX Text
S
AutoCAD SHX Text
TS
AutoCAD SHX Text
7-DAY ASTRONOMIC TIME SWITCH WITH MINIMUM 2 INDEPENDENT CHANNELS. PROVIDE MORE CHANNELS IF DIRECTED BY CONTROL DIAGRAM.
AutoCAD SHX Text
DIMMER SWITCH. CONTRACTOR SHALL CONFIRM COMPATIBILITY WITH LIGHTS CONTROLLED FOR PROPER OPERATION IN COMPLIANCE WITH TITLE 24 TABLE 130.1-A
AutoCAD SHX Text
EXTERIOR POLE MOUNTED PARKING/AREA LIGHT.
AutoCAD SHX Text
#
AutoCAD SHX Text
FINISH FLOOR
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
CL OF HANDLE
AutoCAD SHX Text
CONDUIT STUB OUT
AutoCAD SHX Text
J
AutoCAD SHX Text
#
AutoCAD SHX Text
POWER POLE FOR CONNECTION TO MOD. FURN.
AutoCAD SHX Text
SHEET NOTE TAG
AutoCAD SHX Text
CONDUIT STUB UP
AutoCAD SHX Text
MOTOR RATED DISCONNECT SIZED TO EQUIPMENT NAMEPLATE
AutoCAD SHX Text
JUNCTION BOX, W/ 3/4" EMT STUBBED UP TO HEIGHT AS
AutoCAD SHX Text
DIRECTED BY CLIENT
AutoCAD SHX Text
ELECTRICAL PANEL
AutoCAD SHX Text
SYMBOL
AutoCAD SHX Text
SYMBOL LEGEND-POWER
AutoCAD SHX Text
PNL-CKT
AutoCAD SHX Text
CIRCUIT OR HOMERUN WITH 2#12 HOT LEGS, 1#12 NEUTRAL
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
OR SWITCH
AutoCAD SHX Text
DATA BOX
AutoCAD SHX Text
CONVENIENCE
AutoCAD SHX Text
VISUAL ALARM DEVICE
AutoCAD SHX Text
80" A.F.F. OR 6" BELOW CLG.
AutoCAD SHX Text
WHICHEVER ONE IS LOWER.
AutoCAD SHX Text
15" MIN.
AutoCAD SHX Text
44"
AutoCAD SHX Text
80"
AutoCAD SHX Text
6"
AutoCAD SHX Text
TELEPHONE AND/OR
AutoCAD SHX Text
RECEPTACLE BOX
AutoCAD SHX Text
CONTROL DEVICE
AutoCAD SHX Text
A
AutoCAD SHX Text
N
AutoCAD SHX Text
G
AutoCAD SHX Text
B
AutoCAD SHX Text
HOME RUN TO PANEL WITH 1 HOT LEG, 1 NEUTRAL + 1GND
AutoCAD SHX Text
ALL #12 CU U.O.N.
AutoCAD SHX Text
CIRCUIT OR HOMERUN WITH 3#12HOT LEGS, 1#10 NEUTRAL
AutoCAD SHX Text
AND 1#12 GND U.O.N.
AutoCAD SHX Text
C
AutoCAD SHX Text
A
AutoCAD SHX Text
N
AutoCAD SHX Text
G
AutoCAD SHX Text
B
AutoCAD SHX Text
VERIFY COLOR BEFORE ORDERING DEVICES
AutoCAD SHX Text
MOTOR RATED DISCONNECT, WEATHERPROOF, SIZED TO EQUIPMENT
AutoCAD SHX Text
NAME PLATE RATING. F INDICATES DUAL ELEMENT FUSE PER PHASE.
AutoCAD SHX Text
F
AutoCAD SHX Text
AND 1#12 GND U.O.N.
AutoCAD SHX Text
RATING. F INDICATES DUAL ELEMENT FUSE PER PHASE.
AutoCAD SHX Text
F
AutoCAD SHX Text
WP
AutoCAD SHX Text
G
AutoCAD SHX Text
120V, 15A NEMA 5-15R DUPLEX SPEC GRADE RECEPTACLE LEVITON: 5252 OR EQUAL. 'G' INDICATES GFCI PROTECTED. 'WP' INDICATES GFCI PROTECTED AND WP, GASKETTED COVER. WP WHILE IN USE COVER FOR ANY OUTLET EXPOSED TO DIRECT WATER CONTACT.
AutoCAD SHX Text
(2) 120V, 15A NEMA 5-15R DUPLEX SPEC GRADE RECEPTACLES MOUNTED SIDE-BY-SIDE IN 4 SQUARE BOX. "QUAD RECEPT" LEVITON: 5252 OR EQUAL.
AutoCAD SHX Text
120V, 20A NEMA 5-20R DUPLEX INDUSTRIAL GRADE RECEPTACLE LEVITON: 5352 OR EQUAL
AutoCAD SHX Text
(2) 120V, 20A NEMA 5-20R DUPLEX SPEC GRADE RECEPTACLES MOUNTED SIDE-BY-SIDE IN 4 SQUARE BOX. "QUAD RECEPT" LEVITON: 5352 OR EQUAL
AutoCAD SHX Text
HALF SWITCHED NEMA 5-15R DUPLEX SPEC GRADE RECEPTACLE LEVITON: 5252 OR EQUAL W/ TAB SPLIT.
AutoCAD SHX Text
SPECIAL OUTLET PLUG, REFER TO SHEET NOTES FOR SPEC.
AutoCAD SHX Text
48" MAX.
AutoCAD SHX Text
RECEPTACLE BOX
AutoCAD SHX Text
44" MAX.
AutoCAD SHX Text
48" MAX. TO
AutoCAD SHX Text
TOP OF BOX
AutoCAD SHX Text
SWITCH OR
AutoCAD SHX Text
%%UABBREVIATIONS
AutoCAD SHX Text
CO
AutoCAD SHX Text
WP
AutoCAD SHX Text
UON
AutoCAD SHX Text
NTS
AutoCAD SHX Text
(E)
AutoCAD SHX Text
(N)
AutoCAD SHX Text
EL
AutoCAD SHX Text
NL
AutoCAD SHX Text
AC
AutoCAD SHX Text
UC
AutoCAD SHX Text
MOUNTED ABOVE COUNTER @ 44" TO CENTER. COORDINATE MOUNTING HEIGHT, DEPTH AND ORIENTATION WITH COUNTER MANUFACTURER, ARCHITECT AND CUSTOMERS REP.
AutoCAD SHX Text
CONDUIT ONLY WITH YELLOW POLYPROPELENE PULL ROPE FULL LENGTH OF RACEWAY AND ANCHORED AT EACH END
AutoCAD SHX Text
EXTERIOR LIGHT - ON AT DUSK, OFF AT SET TIME
AutoCAD SHX Text
EXISTING EQUIPMENT
AutoCAD SHX Text
NEW EQUIPMENT
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
NIGHT LIGHT - ON AND OFF WITH PHOTO-CELL/SENSOR
AutoCAD SHX Text
MOUNTED BELOW COUNTER AT STANDARD HEIGHT
AutoCAD SHX Text
UNLESS OTHERWISE NOTED
AutoCAD SHX Text
EQUIPMENT OF WEATHERPROOF CONSTRUCTION
AutoCAD SHX Text
NIC
AutoCAD SHX Text
NOT IN CONTRACT
AutoCAD SHX Text
G
AutoCAD SHX Text
GFCI PROTECTED IF SHOWN BY RECEPTACLE
AutoCAD SHX Text
CU
AutoCAD SHX Text
COPPER CONDUCTOR OR BUS
AutoCAD SHX Text
IG
AutoCAD SHX Text
ISOLATED GROUND CONDUCTOR OR BUS
AutoCAD SHX Text
TYP
AutoCAD SHX Text
TYPICAL FOR ALL OCCURRENCES OF SAME SYMBOL/NOTE
AutoCAD SHX Text
(R)
AutoCAD SHX Text
EXISTING EQUIPMENT TO BE REMOVED
AutoCAD SHX Text
AL
AutoCAD SHX Text
ALUMINUM CONDUCTOR OR BUS
AutoCAD SHX Text
SYMBOL LEGEND-COMMUNICATIONS AND F/A
AutoCAD SHX Text
SYMBOL
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
COMBINATION PHONE AND DATA OUTLET
AutoCAD SHX Text
DUAL DATA OUTLET W/ 2 CAT6 CABLES TO LOCAL MEDIA CAB.
AutoCAD SHX Text
COMBINATION OUTLET, FLOOR MTD.
AutoCAD SHX Text
MEDIA
AutoCAD SHX Text
TENANT TELEPHONE AND CABLE TV MEDIA SUB PANEL
AutoCAD SHX Text
COMBINATION SMOKE AND CARBON MONOXIDE DETECTOR AND ALARM. 120VAC POWERED WITH 12VDC BATTERY BACK UP.
AutoCAD SHX Text
SMOKE DETECTOR AND ALARM. 120VAC POWERED WITH 12VDC BATTERY BACK UP.
AutoCAD SHX Text
DAYLIGHTING SENSOR FOR LOCAL ROOM MULTI-LEVEL CONTROL. REFER
AutoCAD SHX Text
DLS
AutoCAD SHX Text
TITLE 24 CEnC SECTIONS 130.1(d) AND TABLE 130.1-A FOR MORE INFO.
AutoCAD SHX Text
(E)
AutoCAD SHX Text
(E)
AutoCAD SHX Text
(E)
AutoCAD SHX Text
(E) UNDERGROUND FEEDERS: (1) 3" PVC FOR POWER AND (1) 3.5 PVC FOR SIGNAL
AutoCAD SHX Text
(E) FLUSH IN-GRADE PULL BOX # PB81
AutoCAD SHX Text
(E) UNDERGROUND FEEDERS: (1) 3" PVC FOR POWER AND (1) 3.5 PVC FOR SIGNAL
AutoCAD SHX Text
175/3
AutoCAD SHX Text
(E) PANEL 'L1' 400AMP, 277/480V, 3 , 4W
AutoCAD SHX Text
(E)
AutoCAD SHX Text
(E)
AutoCAD SHX Text
300A/3P
AutoCAD SHX Text
100/3
AutoCAD SHX Text
(E)
AutoCAD SHX Text
(E) TRANSFORMER TRANSFORMER 'T1' 112.5KVA
AutoCAD SHX Text
1/0 GEC
AutoCAD SHX Text
5/8"X10' GRND RD
AutoCAD SHX Text
(E) DISTR. PANEL 'DP' 300A, 120/208V, 3ph
AutoCAD SHX Text
(E)
AutoCAD SHX Text
100/3
AutoCAD SHX Text
(E)
AutoCAD SHX Text
150/3
AutoCAD SHX Text
100/3
AutoCAD SHX Text
(E)
AutoCAD SHX Text
(E) PANEL 'R1'
AutoCAD SHX Text
(E) PANEL 'DR1'
AutoCAD SHX Text
(E) PANEL 'DR2'
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
1
AutoCAD SHX Text
E01
AutoCAD SHX Text
NONE
AutoCAD SHX Text
SINGLE LINE DIAGRAM
AutoCAD SHX Text
50/3
AutoCAD SHX Text
(E)
AutoCAD SHX Text
(E) PANEL 'R2'
AutoCAD SHX Text
CEILING MOUNTED SPEAKER
AutoCAD SHX Text
CEILING MOUNTED DROP DOWN MICROPHONE
AutoCAD SHX Text
WAP
AutoCAD SHX Text
WIRELESS ACCESS POINT W/ 1 CAT6 CABLE TO LOCAL MEDIA CAB.
AutoCAD SHX Text
PANEL DR2 NOTES
AutoCAD SHX Text
1. EXISTING CIRCUIT BREAKER TO REMAIN. DISCONNECT EXISTING CONDUCTORS AND REMOVE. CONNECT NEW CIRCUIT CONDUCTORS. EXISTING CIRCUIT BREAKER TO REMAIN. DISCONNECT EXISTING CONDUCTORS AND REMOVE. CONNECT NEW CIRCUIT CONDUCTORS. 2. EXISTING CIRCUIT BREAKER TO REMAIN. DISCONNECT EXISTING CONDUCTORS AND REMOVE. EXISTING CIRCUIT BREAKER TO REMAIN. DISCONNECT EXISTING CONDUCTORS AND REMOVE. 3. EXISTING CIRCUIT BREAKER TO REMAIN. EXISTING CIRCUIT BREAKER TO REMAIN. 4. EXISTING CIRCUIT BREAKER AND CONDUCTORS TO REMAIN. EXISTING CIRCUIT BREAKER AND CONDUCTORS TO REMAIN. 5. REMOVE EXISTING CIRCUIT BREAKER(S) AND CONDUCTORS. INSTALL NEW BREAKER SHOWN AND CONNECT NEW CONDUCTORS.REMOVE EXISTING CIRCUIT BREAKER(S) AND CONDUCTORS. INSTALL NEW BREAKER SHOWN AND CONNECT NEW CONDUCTORS.
AutoCAD SHX Text
D
AutoCAD SHX Text
S
AutoCAD SHX Text
CD
AutoCAD SHX Text
FIRE ALARM HORN/STROBE CANDELA AS INDICATED ON PLANS
364365
356E
356D
356C
356B
356A
356
361
366
357
360
359
358
354
363 M
362W
12
11
10
9
8
PROJECT
N
WE
S
E10
Willia
m F
is
he
r A
rc
hite
ctu
re
, In
c.
60
3 F
ro
nt S
tre
et, S
an
ta
C
ru
z, C
alifo
rn
ia
9
50
60
83
1 2
46
-0
11
7 b
ill@
mo
de
rn
-a
rch
ite
ctu
re
.co
m
mo
de
rn
-a
rch
ite
ctu
re
.co
m
LicensedArchitect
William FisherC-11008
10/31/19
RENEWS ON
A
I
N
O
F
I
L
A
R
C
Date Printed:
9/10/2019
Cabrillo C
ollege
Room
356, B
uilding 350
2600 S
oquel A
ve.
Aptos, C
A 95003
Issue Date
Revision Schedule
Rev. No. Date
303 P
OT
RE
RO
S
T. S
UIT
E 42-304
SA
NT
A C
RU
Z, C
A 95060
PH
ON
E: (831)430-3605
FA
X: (831)430-9490
PD
G P
RO
JE
CT
N
O.: 19120.00
PR
IM
E D
ES
IG
N G
RO
UP
ELE
CT
RIC
AL F
LO
OR
PLA
NS
- D
EM
O
AutoCAD SHX Text
EXISTING PANEL 'DR1'
AutoCAD SHX Text
EXISTING PANEL 'DR2'
AutoCAD SHX Text
EXISTING PANEL 'R1'
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
4
AutoCAD SHX Text
TYPICAL
AutoCAD SHX Text
3
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
1
AutoCAD SHX Text
E10
AutoCAD SHX Text
1/4"=1'-0"
AutoCAD SHX Text
EXISTING/DEMOLITION PLAN
AutoCAD SHX Text
KEYED SHEET NOTES
AutoCAD SHX Text
EXISTING PANEL TO REMAIN AS IS
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
EXISTING PANEL. "DR2". CONTRACTOR SHALL DISCONNECT CIRCUIT CONDUCTORS FROM ALL CIRCUIT BREAKERS SERVING ELECT. EQUIPMENT BEING REMOVED. SEE NEW ELECT. PLAN AND PANEL SCHEDULES FOR NEW CIRCUIT REQUIREMENTS.
AutoCAD SHX Text
CONTRACTOR SHALL REMOVE ALL POWER, LIGHTING AND LOW VOLTAGE EQUIPMENT AS ASSOCIATED CONTROL DEVICES, EXPOSED RACEWAYS AND CONDUCTORS BACK TO SOURCE.
AutoCAD SHX Text
4
AutoCAD SHX Text
TYPICAL EXISTING WALL TO BE REMOVED.
12
11
10
9
8
13
D E H J
Mechanical Equipment Pad on
Lower level
PROJECT
N
WE
S
E20
Willia
m F
is
he
r A
rc
hite
ctu
re
, In
c.
603 F
ront S
treet, S
anta C
ruz, C
alifornia 95060
831 246-0117 bill@
modern-architecture.com
modern-architecture.com
LicensedArchitect
William FisherC-11008
10/31/19
RENEWS ON
A
I
N
O
F
I
L
A
R
C
Date Printed:
9/10/2019
Cabrillo C
ollege
Room
356, B
uilding 350
2600 S
oquel A
ve.
Aptos, C
A 95003
Issue Date
Revision Schedule
Rev. No. Date
303 P
OT
RE
RO
S
T. S
UIT
E 42-304
SA
NT
A C
RU
Z, C
A 95060
PH
ON
E: (831)430-3605
FA
X: (831)430-9490
PD
G P
RO
JE
CT
N
O.: 19120.00
PR
IM
E D
ES
IG
N G
RO
UP
ELE
CT
RIC
AL P
OW
ER
P
LA
N
AutoCAD SHX Text
EXISTING PANEL 'DR2'
AutoCAD SHX Text
DR2-CKT
AutoCAD SHX Text
IU
AutoCAD SHX Text
201
AutoCAD SHX Text
DR2-8,10
AutoCAD SHX Text
+60"
AutoCAD SHX Text
+60"
AutoCAD SHX Text
+60"
AutoCAD SHX Text
OU
AutoCAD SHX Text
201
AutoCAD SHX Text
F
AutoCAD SHX Text
WP
AutoCAD SHX Text
WP
AutoCAD SHX Text
DR2-2,4,6
AutoCAD SHX Text
#8
AutoCAD SHX Text
5
AutoCAD SHX Text
DR2-13
AutoCAD SHX Text
DR2-3
AutoCAD SHX Text
DR2-5
AutoCAD SHX Text
DR2-3
AutoCAD SHX Text
DR2-3
AutoCAD SHX Text
5
AutoCAD SHX Text
DR2-15
AutoCAD SHX Text
DR2-5
AutoCAD SHX Text
DR2-1
AutoCAD SHX Text
DR2-1
AutoCAD SHX Text
DR2-11
AutoCAD SHX Text
5
AutoCAD SHX Text
2
AutoCAD SHX Text
#10
AutoCAD SHX Text
DR2-1
AutoCAD SHX Text
DR2-1
AutoCAD SHX Text
+60"
AutoCAD SHX Text
DR2-7
AutoCAD SHX Text
DR2-9
AutoCAD SHX Text
4
AutoCAD SHX Text
3
AutoCAD SHX Text
6
AutoCAD SHX Text
CLG.
AutoCAD SHX Text
7
AutoCAD SHX Text
DR2-14
AutoCAD SHX Text
8
AutoCAD SHX Text
J
AutoCAD SHX Text
J
AutoCAD SHX Text
DR2-16
AutoCAD SHX Text
9
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
1
AutoCAD SHX Text
E20
AutoCAD SHX Text
1/4"-1'-0"
AutoCAD SHX Text
ELECTRICAL POWER PLAN
AutoCAD SHX Text
GENERAL SHEET NOTES
AutoCAD SHX Text
VERIFY ALL EQUIPMENT LOCATIONS AND HEIGHTS WITH CABRILLO COLLEGE.
AutoCAD SHX Text
KEYED SHEET NOTES
AutoCAD SHX Text
NEW OUTDOOR HVAC UNIT "OU-1": 35 MCA, 208V, 3ɸ.
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
FOR CONNECTION OF MEDIA CART.
AutoCAD SHX Text
FOR CONNECTION OF PROJECTION SCREEN.
AutoCAD SHX Text
FOR CONNECTION OF LED TV.
AutoCAD SHX Text
SEE PANEL SCHEDULE FOR REQUIREMENTS.
AutoCAD SHX Text
NEW INDOOR HVAC UNIT "IU-1": 4.29 MCA, 208V, 3ɸ.
AutoCAD SHX Text
7
AutoCAD SHX Text
FLUSH CEILING RECEPTACLE FOR WIRELESS ACCESS POINT POWER
AutoCAD SHX Text
8
AutoCAD SHX Text
RECEPTACLE AT +7'-0" FOR CONNECTION OF SECURITY ALARM PANEL TRANSFORMER. SECURITY ALARM SYSTEM COMPONENTS AND INSTALLATION TO BE INCLUDED IN GENERAL CONTRACTOR'S BID.
AutoCAD SHX Text
9
AutoCAD SHX Text
FLUSH J-BOXES WITH 120V CIRCUIT CONDUCTORS IN CONCEALED 3/4" CONDUIT AND CONNECTIONS TO DOOR ACTUATOR, INDOOR ADA PUSHBUTTON AND EXTERIOR ADA PUSHBUTTON. VERIFY EXACT REQUIREMENTS AND LOCATIONS WITH ARCHITECT AND EQUIPMENT MANUHACTURER.
12
11
10
9
8
13
D E H J
PROJECT
N
WE
S
E40
Willia
m F
is
he
r A
rc
hite
ctu
re
, In
c.
60
3 F
ro
nt S
tre
et, S
an
ta
C
ru
z, C
alifo
rn
ia
9
50
60
83
1 2
46
-0
11
7 b
ill@
mo
de
rn
-a
rch
ite
ctu
re
.co
m
mo
de
rn
-a
rch
ite
ctu
re
.co
m
LicensedArchitect
William FisherC-11008
10/31/19
RENEWS ON
A
I
N
O
F
I
L
A
R
C
Date Printed:
9/10/2019
Cabrillo C
ollege
Room
356, B
uilding 350
2600 S
oquel A
ve.
Aptos, C
A 95003
Issue Date
Revision Schedule
Rev. No. Date
303 P
OT
RE
RO
S
T. S
UIT
E 42-304
SA
NT
A C
RU
Z, C
A 95060
PH
ON
E: (831)430-3605
FA
X: (831)430-9490
PD
G P
RO
JE
CT
N
O.: 19120.00
PR
IM
E D
ES
IG
N G
RO
UP
ELE
CT
RIC
AL LO
W
VO
TLA
GE
/ S
IG
NA
L P
LA
N
ELEC.
UP
ROOM
MECH.
ROOM
PROJECT
N
WE
S
AutoCAD SHX Text
EXISTING PANEL 'DR2'
AutoCAD SHX Text
CLG.
AutoCAD SHX Text
CLG.
AutoCAD SHX Text
CLG.
AutoCAD SHX Text
CLG.
AutoCAD SHX Text
WAP
AutoCAD SHX Text
1
AutoCAD SHX Text
+60"
AutoCAD SHX Text
+60"
AutoCAD SHX Text
+60"
AutoCAD SHX Text
+60"
AutoCAD SHX Text
30CD
AutoCAD SHX Text
30CD
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
1
AutoCAD SHX Text
E40
AutoCAD SHX Text
1/4"-1'-0"
AutoCAD SHX Text
ELECTRICAL LOW VOLTAGE SIGNAL PLAN
AutoCAD SHX Text
GENERAL SHEET NOTES
AutoCAD SHX Text
SEE SHEET E01 FOR SYMBOL LEGEND. VERIFY ALL LOCATIONS AND REQUIREMENTS WITH CABRILLO COLLEGE.
AutoCAD SHX Text
KEYED SHEET NOTES
AutoCAD SHX Text
CEILING PROJECTOR. PROVIDE POWER AND MEDIA CABLE TO SOURCE AS DIRECTED.
AutoCAD SHX Text
1
AutoCAD SHX Text
(E) FIRE ALARM PANEL NOTIFIER NFS-320
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
2
AutoCAD SHX Text
E40
AutoCAD SHX Text
1/4"-1'-0"
AutoCAD SHX Text
FIRE ALARM PANEL LOCATION PLAN LOWER LEVEL
AutoCAD SHX Text
EXISTING (2) 12V 7Ah BATTERIES
AutoCAD SHX Text
EXISTING FACP-8 NOTIFIER NSF-320
AutoCAD SHX Text
NAC-109
AutoCAD SHX Text
(E) DEDICATED 120V, 20A CIRCUIT WITH RED MARKINGS LABELED "FIRE ALARM CONTROL CIRCUIT"