Online data sheet C40S-1502CI010 C4000 Entry/Exit SAFETY LIGHT CURTAINS
8

C4000 Entry/Exit C40S-1502CI010, Online data sheet · Resolution 20 mm Synchronization ... Configuration method PC with CDS ... Brief description Type Part no. 4 pieces, Mounting

Aug 19, 2018

Download

Documents

dangdang
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: C4000 Entry/Exit C40S-1502CI010, Online data sheet · Resolution 20 mm Synchronization ... Configuration method PC with CDS ... Brief description Type Part no. 4 pieces, Mounting

On

lin

e d

ata

sh

ee

t

C40S-1502CI010C4000 Entry/Exit

SAFETY LIGHT CURTAINS

Page 2: C4000 Entry/Exit C40S-1502CI010, Online data sheet · Resolution 20 mm Synchronization ... Configuration method PC with CDS ... Brief description Type Part no. 4 pieces, Mounting

ABCDEF

HIJKLMNOPQRST

C40S-1502CI010 | C4000 Entry/ExitSAFETY LIGHT CURTAINS

Ordering information

Type Part no.

C40S-1502CI010 1024050

Other models and accessories www.sick.com/C4000_Entry_Exit

Detailed technical data

FeaturesProtective field height 1,500 mm

Resolution 20 mm

Synchronization Optical synchronisation

Safety-related parametersType Type 4 (IEC 61496-1)

Safety integrity level SIL3 (IEC 61508)SILCL3 (EN 62061)

Category Category 4 (EN ISO 13849)

Performance level PL e (EN ISO 13849)

PFHD (mean probability of a dangerous fail-ure per hour)

1.5 x 10-8 (EN ISO 13849)

TM (mission time) 20 years (EN ISO 13849)

Safe state in the event of a fault At least one OSSD is in the OFF state.

FunctionsBeam coding ✔

Safe SICK device communication via EFI ✔

InterfacesSystem connection

Connection type Hirschmann male connector M26, 12-pin

Permitted cable length ≤ 50 m 1)

Conductor cross-section 0.75 mm²

Configuration connection

Connection type Female connector M8, 4-pin

Configuration method PC with CDS (Configuration and Diagnostic Software)

Display elements 7-segment display

Fieldbus, industrial network

Integration via EFI gateways CANopen, Ethernet, PROFIBUS DP, PROFIBUS PROFIsafe, PROFINET PROFIsafe 2)

1) Depending on load, power supply and wire cross-section. The technical specifications must be observed.2) For a suitable EFI-gateway see modules and gateways in the accessory section of connection systems.3) For additional information on Flexi Soft -> www.sick.com/Flexi_Soft.

2 OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK Online data sheet | 2018-06-16 08:58:37

Subject to change without notice

Page 3: C4000 Entry/Exit C40S-1502CI010, Online data sheet · Resolution 20 mm Synchronization ... Configuration method PC with CDS ... Brief description Type Part no. 4 pieces, Mounting

C40S-1502CI010 | C4000 Entry/ExitSAFETY LIGHT CURTAINS

Integration via Flexi Soft safety controller CANopen, DeviceNet™, EtherCAT®, EtherNet/IP™, Modbus TCP, PROFIBUS DP, PROFINET 3)

1) Depending on load, power supply and wire cross-section. The technical specifications must be observed.2) For a suitable EFI-gateway see modules and gateways in the accessory section of connection systems.3) For additional information on Flexi Soft -> www.sick.com/Flexi_Soft.

Electrical data

Protection class III (EN 50178)

Power consumption 1 A

Mechanical data

Housing cross-section 48 mm x 40 mm

Weight 3,110 g

Ambient data

Enclosure rating IP65 (IEC 60529)

Ambient operating temperature 0 °C ... +55 °C

Storage temperature –25 °C ... +70 °C

Air humidity 15 % ... 95 %, Non-condensing

Vibration resistance 5 g, 10 Hz ... 55 Hz (EN 60068-2-6)

Shock resistance 10 g, 16 ms (EN 60068-2-27)

Other information

Wave length 950 nm

Classifications

ECl@ss 5.0 27272704

ECl@ss 5.1.4 27272704

ECl@ss 6.0 27272704

ECl@ss 6.2 27272704

ECl@ss 7.0 27272704

ECl@ss 8.0 27272704

ECl@ss 8.1 27272704

ECl@ss 9.0 27272704

ETIM 5.0 EC002549

ETIM 6.0 EC002549

UNSPSC 16.0901 46171620

2018-06-16 08:58:37 | Online data sheet

Subject to change without notice

OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK 3

Page 4: C4000 Entry/Exit C40S-1502CI010, Online data sheet · Resolution 20 mm Synchronization ... Configuration method PC with CDS ... Brief description Type Part no. 4 pieces, Mounting

ABCDEF

HIJKLMNOPQRST

C40S-1502CI010 | C4000 Entry/ExitSAFETY LIGHT CURTAINS

Dimensional drawing (Dimensions in mm (inch))

40 (1.57)20

(0.79)

DIN 43651 plug(M26 x 11 + FE)

DIN 43651 socket(M26 x 11 + FE)

Ca

. 1

40

(5

.51

)(c

on

ne

cto

r ra

nge

)

Cable sockets M26 x 11 + FE with crimp contacts

Ca

. 1

00

(3

.94

)(c

on

ne

cto

r ra

nge

)

Cable plug M26 x 11 + FEwith crimp contacts

Ca

. 1

50

(5

.91

)(c

on

ne

cto

r ra

nge

)

46

.5(1

.83

)

L2

L1

S

36

.2(1

.43

)

56

.3(2

.22

)

A7

4 (

2.9

1)

48(1.89)

22.4(0.88)

10

0 (

3.9

4)

75

(2

.95

)65 (2.56)

11

0 (

4.3

3)

Sliding nut groovefor side mounting

14(0.55)

6(0.24)

2.2

(0.0

9)

1(0

.04

)

3.5

(0.1

4)

10.5(0.41)

Illustration sender (receiver mirror image)

4 OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK Online data sheet | 2018-06-16 08:58:37

Subject to change without notice

Page 5: C4000 Entry/Exit C40S-1502CI010, Online data sheet · Resolution 20 mm Synchronization ... Configuration method PC with CDS ... Brief description Type Part no. 4 pieces, Mounting

C40S-1502CI010 | C4000 Entry/ExitSAFETY LIGHT CURTAINS

DIN 43651 plug(M26 x 11 + FE)

Sliding nut groovefor side mounting

Ca

. 1

40

(5

.51

)(c

on

ne

cto

r ra

nge

)

Cable sockets M26 x 11 + FE with crimp contacts

Ca

. 1

00

(3

.94

)(c

on

ne

cto

r ra

nge

)

40(1.57)

20(0.79)

10

(0.3

9)

L2

L1

S

A

36

.2(1

.43

)

56

.3(2

.22

)

48 (1.89)22.4(0.88)

74

(2

.91

)

14(0.55)

6(0.24)

2.2

(0.0

9)

1(0

.04

)

3.5

(0.1

4)

10.5(0.41)

10

0 (

3.9

4)

75

(2

.95

)

65 (2.56)

Illustration sender (receiver mirror image)

Recommended accessoriesOther models and accessories www.sick.com/C4000_Entry_Exit

Brief description Type Part no.

Mounting brackets and plates

4 pieces, Mounting kit 1, mounting bracket, rigid, L-shaped, including fixing screwsand washers

BEF-3WNGBAST4 7021352

Terminal and alignment brackets

4 pieces, Mounting kit 6, side bracket, rotatable, Zinc diecast BEF-1SHABAZN4 2019506

4 pieces, Omega bracket, rotatable, fixable with only one screw, for mounting on theswivel mount

BEF-2SMMEAAL4 2044847

2018-06-16 08:58:37 | Online data sheet

Subject to change without notice

OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK 5

Page 6: C4000 Entry/Exit C40S-1502CI010, Online data sheet · Resolution 20 mm Synchronization ... Configuration method PC with CDS ... Brief description Type Part no. 4 pieces, Mounting

ABCDEF

HIJKLMNOPQRST

C40S-1502CI010 | C4000 Entry/ExitSAFETY LIGHT CURTAINS

Brief description Type Part no.

4 pieces, Mounting kit 2, rotatable, swivel mount, Polyamide PA6 BEF-2SMMEAKU4 2019659

Switching amplifiers

Expands C4000 Standard, Advanced, Palletizer, Entry/Exit and Fusion with the func-tions described in the technical data, e.g., bypass, operating mode switching or in ad-dition PSDI mode on C4000 Standard, Advanced.

UE402 1023577

Plug connectors and cables

Head A: female connector, M26, 12-pin, straightHead B: Flying leadsCable: PVC, unshielded, 5 mWithout EFI: Pin 9 and 10 not connected

DOL-0610G05M075KM1 2046888

Head A: female connector, M26, 12-pin, straightHead B: Flying leadsCable: PVC, unshielded, 10 mWithout EFI: Pin 9 and 10 not connected

DOL-0610G10M075KM1 2046889

Head A: female connector, M26, 12-pin, straightHead B: Flying leadsCable: PVC, unshielded, 5 m

DOL-0612G05M075KM0 2022545

Head A: female connector, M26, 12-pin, straightHead B: Flying leadsCable: PVC, unshielded, 10 m

DOL-0612G10M075KM0 2022547

Head A: female connector, M26, 12-pin, straightHead B: Flying leadsCable: PVC, unshielded, 15 m

DOL-0612G15M075KM0 2022548

Head A: female connector, M26, 12-pin, straightHead B: Flying leadsCable: PVC, unshielded, 20 m

DOL-0612G20M075KM0 2022549

Head A: male connector, M8, 4-pin, straightHead B: male connector, USB-A, straightCable: PVC, unshielded, 2 m

DSL-8U04G02M025KM1 6034574

Head A: male connector, M8, 4-pin, straightHead B: male connector, USB-A, straightCable: PVC, unshielded, 10 m

DSL-8U04G10M025KM1 6034575

Head A: female connector, M26, 12-pin, straightCable: unshielded12 crimping contacts enclosed

DOS-0612G000GA3KM0 6020757

Head A: female connector, M26, 12-pin, angledCable: unshielded12 crimping contacts enclosed

DOS-0612W000GA3KM0 6020758

Alignment aids

Laser alignment aid for various sensors, laser class 2 (IEC 60825). Do not look intothe beam!

AR60 1015741

Adapter AR60 for housing cross-section 48 mm x 40 mm AR60 adapter, 48x40 4032461

Adapter AR60 for housing cross-section 48 mm x 40 mm in PU3H device column AR60 adapter,48x40, PU3H

4056731

6 OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK Online data sheet | 2018-06-16 08:58:37

Subject to change without notice

Page 7: C4000 Entry/Exit C40S-1502CI010, Online data sheet · Resolution 20 mm Synchronization ... Configuration method PC with CDS ... Brief description Type Part no. 4 pieces, Mounting

C40S-1502CI010 | C4000 Entry/ExitSAFETY LIGHT CURTAINS

Brief description Type Part no.

Test and monitoring tools

20 mm diameter Test rod 20 mm 2022600

2018-06-16 08:58:37 | Online data sheet

Subject to change without notice

OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK 7

Page 8: C4000 Entry/Exit C40S-1502CI010, Online data sheet · Resolution 20 mm Synchronization ... Configuration method PC with CDS ... Brief description Type Part no. 4 pieces, Mounting

Onlin

e da

ta s

heet

SICK AG | Waldkirch | Germany | www.sick.com

SICK At A GlAnCeSICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applica-tions. A unique range of products and services creates the perfect basis for controlling processes securely and efficiently, protecting individuals from accidents and preventing damage to the environment.

We have extensive experience in a wide range of industries and understand their processes and require-ments. With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe, Asia and North America, system solutions are tested and optimized in accordance with customer specifications. All this makes us a reliable supplier and development partner.

Comprehensive services complete our offering: SICK lifetime Services provide support throughout the ma-chine life cycle and ensure safety and productivity.

For us, that is “Sensor Intelligence.”

WOrldWIde preSenCe:Contacts and other locations – www.sick.com