8/13/2019 C200_eng
1/12
Pressures to 30.000 psi
8/13/2019 C200_eng
2/122 Este catalogo est disponible en espaol en www.abac.com.ar
Contentpage
ThreadsTaper: NPT standard threads, according ANSI B1.20.1
Lnea Media Presin
High pressure fittings
Medium pressure fittings
Maximum allowable working pressures
How to OrderTheABAC numbering system allows identifying easily,
the fitting type, threading size and material.
The union service pressure will be given by the mnimum
working admisible pressure of the ends that is composed
(*) Silver zinc plated treatment, thickness 10/12 microns, in carbn steel accesories
A PTFE tape or thread sealant should always be used when assembling tapered threads
Not applicable to nipples, half couples or brass acceories
Type (eg. Reducing bushing)
Material: 316: stainless steel AISI 316
C: carbon steel
B: brass
Pipe connections. in eighteenths of an inch
(eg. 1/4 x 1/8)
BUR 2 - 1 316
Allowable working pressure (psi) Size
thread
(inches)
1/8 7300 12300 5700 9700
1/4 7300 9900 5400 7800
Straight Tee or elbow
Female Male Female Male
3/8 5500 9000 5000 7500
1/2 4900 8900 4600 7400
3/4 3700 8300 4100 6900
1 4300 5900
Materials (*)
General Information
St. steel AISI 316 Bars ASTM A276
Forgings ASTM A182Carbon steel Bars SAE1040
Forgings ASTM A105
Type Variety Standards
Taper NPT
Coned and threaded AU
15000
30000
Thread Allowable working pressure (psi)
General information ........... 2
Medium pressure fittings
Coupling .............................................. 3
Reducing bushings ............................. 3
Reducing adapter ............................... 3
Adapters .............................................. 4
Nipples ................................................ 4
Hex nipples ......................................... 4
Hex reducing nipple ............................ 5
Elbows ................................................ 5
Tees .................................................... 6
Plugs ................................................... 6
High pressure fittings
NPT threaded connections
Coupling ............................................... 7
Hex nipples ......................................... 7
Elbows ................................................ 7
Tees ..................................................... 7
AU coned-and-threaded connections
Coupling ............................................... 8
Reducing bushing ............................... 8
Reducing adapter ................................ 8
Hex nipples ......................................... 8
Hex reducing nipple ............................ 9
Elbows ................................................ 9
Tees .................................................... 9
Plug ..................................................... 9
Combined connections
Adapters ............................................. 10
Other models
ACDDielectric coupler ...................... 11
Coned-and-cylindrical threaded:
(1) Compatible with F250C AUTOCLAVE connection(2) Compatible with F562C AUTOCLAVE connections
1/4 AU
9/16 AU
1/4
9/16
11.1
19
4.75
11.1
2.5
6.35
UNF 9/16 x 18 hpp (1)
UNF 11/8 x 12 hpp (2)
NameDimensions (mm)
A C DR
Outsidetube
diameter
60
R
C
D
A
+1-0
8/13/2019 C200_eng
3/123
CUP Coupling
MEASURES (mm)Model
CUP-1- 1/8 21 14.3 8.5
CUP-2- 1/4 30 19.05 11.2
NPT thread
L E D
CUP-3- 3/8 32 22.2 14
CUP-4- 1/2 40 27.0 18
CUP-6- 3/4 45 38.1 23
CUP-8- 1 51 44.4 28
MEDIUM PRESSURE
CUR Reducing Coupling
MEASURES (mm)Model
CUR-3-2- 3/8 32 22.2 11.5
CUR-4-2- 1/2 37 27 11.5
NPT thread
LR1 R2 E D
CUR-4-3- 1/2 37 27 14
CUR-6-2- 3/4 40 38.1 11.5
CUR-6-3- 3/4 40 38.1 14
CUR-6-4- 3/4
1/4
1/4
3/8
1/4
3/8
CUR-8-6- 1 55 44.4 233/4
1/2 45 38.1 18
MEASURES (mm)
Model
BUR-2-1- 1/4 25 14.3 7
BUR-3-2- 3/8 32 19.1 10
NPT thread
LR1 R2 E D
BUR-4-2- 1/2 28 22.2 11.5
BUR-4-3- 1/2 35 22.2 12
BUR-6-2- 3/4 43 27 11.5
BUR-6-4- 3/4
1/8
1/4
1/4
3/8
1/4
BUR-8-4- 1 40 34.92 16.51/2
BUR-8-6- 1 47 34.92 223/4
1/2 30 27 16.5
ADR Reducing Adapter
MEASURES (mm)
Model
ADR-2-1- 1/4 19 30 4
ADR-4-2- 1/2 27 45 7
NPT thread
ER M L D
ADR-4-3- 1/2 27 45 9.5
ADR-6-4- 3/4 34.9 50 12
1/8
1/4
3/8
1/2
BUR Reducing Bushing
8/13/2019 C200_eng
4/124
ADN NPTF-BSPM Adapter
MEASURES (mm)Model
ADN-2-2-
ADN-3-3-
Thread
ADN-4-4-
1/4
3/8
R
1/2
19.05
22.2
E
27
38
40
L
45
5
5
D
5
M
1/4
3/8
1/2
ADB BSPF-NPTM Adapter
MEASURES (mm)
Model
ADB-2-2-
ADB-3-3-
Thread
ADB-4-4-
1/4
3/8
R
1/2
19.05
22.2
E
27
35
37
L
45
5
5
D
5
M
1/4
3/8
1/2
ALR Lap-Joint to Thread Adapter
MEASURES (mm)Model
ALR-4-4-
ALR-4-6-
1/2
1/2
NPT
thread
70
73
L
34.9
42.9
A
10.5
10.5
D
Flange
Size (*)
1/2
3/4
21.3
26.9
B
(*) For use with ANSI #150 and #300 lap joint pipe flanges. Smooth finish sealing surface
NIP Nipple
MEASURES (mm)Model
NIP-2-07-
NIP-2-10-
NIP-2-15-
NIP-4-07-
NIP-4-10-
NIP-4-15-NIP-4-20-
1/4
1/4
NPT thread
1/4
1/2
1/2
1/21/2
75
100
L
150
75
100
150200
13.75
13.75
E
13.75
21.34
21.34
21.3421.34
To order, insert suffix 40 to indicate SCH40 and 80 for SCH 80. Ex: NIP 4-10-80-316
ENT Hex Nipple
MEASURES (mm)Model
ENT-1- 1/8
ENT-2- 1/4
NPT thread
ENT-3- 3/8
ENT-4- 1/2
ENT-6- 3/4
ENT-8- 1
30
40
L
40
50
55
62
11.1
14.3
E
17.4
22.2
27
34.9
5
7
D
10
12
16
23
MEDIUM PRESSURE
8/13/2019 C200_eng
5/125
ENR Hex Reducing Nipple
MEASURES (mm)Model
ENR-2-1- 1/8
ENR-4-2- 1/4
NPT thread
R1 R2
ENR-4-3- 3/8
ENR-6-4- 1/2
14.3
22.2
E
22.2
27
32
43
L
43
49
4.75
6
D
8
11
1/4
1/2
1/2
3/4
MEDIUM PRESSURE
CHH Female Elbow
CMM Male Elbow
COR Reducing Elbow
CMH Male-Female Elbow
MEASURES (mm)Model
CMM-1- 1/8
CMM-2- 1/4
NPT thread
CMM-3- 3/8
CMM-4- 1/2
26.3
32.8
A
37.3
44
19
25.5
L
27.5
33
4.75
7
D
7.5
10.5
MEASURES (mm)
Model
CHH-1- 1/8
CHH-2- 1/4
NPT thread
CHH-3- 3/8
CHH-4- 1/2
26.3
31.8
A
35.3
44
19
22
L
25.5
29
8.5
11
D
14
17
MEASURES (mm)
Model
COR-3-2- 3/8COR-4-2- 1/2
NPT thread
31.831.8
A1M R
3740.3
A2
1/41/4
2222
L1
2833
L2
1010.5
D
MEASURES (mm)
Model
CMH-1- 26.3 26.3
CMH-2- 38.8 31.8
NPT threadA1 A2
1/8
1/4
19
29
L1
20
22
L2
5
7
CMH-3- 37.3 35.3
CMH-4- 55 44
3/8
1/2
27.5
40
25.5
29
10.5
12
D
8/13/2019 C200_eng
6/126
TAP Plug
MEASURES (mm)Model
TAP-1- 1/8 16 11.1
TAP-2- 1/4 22 14.3
NPT threadL E
TAP-3- 3/8 22 17.5
TAP-4- 1/2 28 22.2
TAP-6- 3/4 32 27
TAP-8- 1 38 34.9
THH Female Tee
MEASURES (mm)Model
THH-1- 1/8 47 34.5 8
THH-2- 1/4 51 36.5 11.25
NPT thread
A B D
THH-3- 3/8 60 45 14
THH-4- 1/2 76 54 17.5
THH-6- 3/4 80 55 23
23.5
25.5
C
34.5
38
40
MEASURES (mm)Model
TMM-1- 1/8 48 30 5
TMM-2- 1/4 51 32.5 7.5
NPT threadA B D
TMM-3- 3/8 61 42.5 7.5
TMM-4- 1/2 65 45 10.5
TMM-6- 3/4 80 56 16
23
25.5
C
32
34
40
TMM Male Tee
TML Male Run Tee
MEASURES (mm)
Model
TML-2- 1/4 63 44.5 7
NPT thread
AR1 M B D
1/41/4
R2
34
C
TMC Male Branch Tee
MEASURES (mm)Model
TMC-2- 1/4 63 44.5 7.5
NPT thread
AR1 M B D
1/41/4
R2
34
C
MEDIUM PRESSURE
8/13/2019 C200_eng
7/127
CUPA Coupling
ENTA Hex nipple
ENRA Hex Reduing Nipple
MEASURES (mm)
Model
CUPA-2- 1/4 30 25.4 10.6
CUPA-4- 1/2 44 38.1 17.35
NPT threadL E D
CHHA NPT Female Elbow
MEASURES (mm)
Model
CHHA-2- 1/4
CHHA-4- 1/2
NPT thread
38.1
57.1
L1
38.1
57.1
L2
25.4
38.1
Tick
10.6
D
17.35
25.4
38.1
A1
25.4
38.1
A2
THHA NPT Female Tee
MEASURES (mm)
Model
THHA-2- 1/4
THHA-4- 1/2
NPT thread
50.8
57.1
L1
50.8
63.5
L2
25.4
38.1
Tick
10.6
D
17.35
25.4
31.75
A1
25.4
38.1
A2
MEASURES (mm)
Model
ENTA-2- 1/4 40 14.3 5
ENTA-4- 1/2 50 22.2 8
NPT threadL E D
CURA Reducing coupling
MEASURES (mm)
Model
CURA-4-2- 1/2 37 38.1 10.6
NPT thread
LR1 R2 E D
1/4
MEASURES (mm)
Model
ENRA-4-2- 1/2 43 22.2 5
NPT thread
LR1 R2 E D
1/4
HIGH PRESSURE - NPT THREAD
8/13/2019 C200_eng
8/128
CUPH Coupling
BURH Reducing bushing
ADRH Reducing Adapter
MEASURES (mm)
Model
CUPH-2- 1/4 32 22.2 2.5
CUPH-5- 9/16 51 38.1 6.35
AUF connections
L E D
MEASURES (mm)
Model
ENTH-2- 1/4 43 15.8 2.5
ENTH-5- 9/16 83.1 31.7 6.35
AUM connectionsL E D
ENTH Hex Nipple
CURH Reducing coupling
MEASURES (mm)
Model
CURH-5-2- 9/16 45 38.1 2.5
AUF connections
LR1 R2 E D
1/4
MEASURES (mm)
Model
BURH-5-2- 9/16 49.05 31.7 2.5
AU connections
LR1 R2 E D
1/4
MEASURES (mm)
Model
ADRH-5-2- 9/16 50 38.1 2.5
AU connections
LR1 R2 E D
1/4
HIGH PRESSURE - CONED AND THREADED AU
8/13/2019 C200_eng
9/129
ENRH Hex ReduCing Nipple
THHHAU Tee
MEASURES (mm)
Model
THHH-2- 1/4
THHH-5- 9/16
AUF
connections
31.75
57.1
L1
31.75
63.5
L2
22.2
38.1
Tick.
2.5
D
6.35
15.88
31.75
A1
19.05
38.1
A2
MEASURES (mm)
Model
TAPH-2- 1/4
TAPH-5- 9/16
AUM
connections
28.6
45.6
L1
20.6
35
L2
15.8
31.7
E
CHHHAU Elbow
MEASURES (mm)
Model
CHHH-2- 1/4
CHHH-5- 9/16
AUF
connections
31.7
57.1
L1
31.7
57.1
L2
22.2
38.1
Tick
2.5
D
6.35
19.05
38.1
A1
19.05
38.1
A2
TAPHAU Plug
MEASURES (mm)
Model
ENRH-5-2- 9/16 66.5 31.7 2.5
AUM connections
LR1 R2 E D
1/4
HIGH PRESSURE - CONED AND THREADED AU
8/13/2019 C200_eng
10/120
ADAHAUM to NPTF Adapter
ADHAAUF to NPTM Adapter
MEASURES (mm)
Model
ADAH-2-2- 1/4 40 25.4 2.5
ADAH-2-4- 1/4 50 38.1 2.5
AUM-NPTF Connections
LR1 R2 E D
ADAH-5-2- 9/16 52.05 31.7 6.35
1/4
1/2
ADAH-5-4- 9/16 66.55 38.1 6.351/2
1/4
MEASURES (mm)
Model
ADHA-2-2- 1/4 31.5 22.2 2.5
ADHA-2-4- 1/4 34.1 22.2 2.5
AUF-NPTM Connections
LR1 R2 E D
ADHA-5-2- 9/16 44 38.1 5
1/4
1/2
ADHA-5-4- 9/16 47.5 38.1 6.351/2
1/4
HIGH PRESSURE - COMBINED CONNECTION
8/13/2019 C200_eng
11/1211
ACD Dielectric Coupler
Standard materials
(*) See installment required measures
Technical Specifications
Installment required measures
Accessory designed to isolate electrical currents in metal pipes,
while offering a large flow rate and resistance to high pressures.
In industrial plants it is desirable to protect measuring and control
instruments, isolating them from electrical currents generated byapplication of cathodic protection, statics current, etc.
The device is specially designed for use in CNG facilities, installed
between the compressor and the storage, transport units and
dispensers.
Ends
Nut
AISI 316
AISI 316
Isolating flange
Seals
Acetal
Buna
Rating
Max.operating pressure
Temperature rating
(*)
212F
Electrical resistance of insulator
Breakdown voltaje
Measures (mm)
Model End connections CVOperating
pressure @ 70F(psi)
ACD 50 MM-I 88 34.9 31.7
ACD 50 MH-I 88 34.9 31.7
A B C
ACD 50 HH-I 114 34.9 31.7
ACD 75 MM-I 103 44.4 38.1
ACD 75 MH-I 103 44.4 38.1
ACD 75 HH-I
ACD 80 MM-I 130 50.8 44.4
ACD 80 MH-I 130 50.8 44.4
134 44.4 38.1
-
-
D
27
-
-
-
-
34.9
10
10
Orifice
10
15
15
22
22
15
12
12
12
24
24
50
50
24
ACD 80 HH-I
1/2 MM NPT
1/2 MH NPT
1/2 HH NPT
3/4 MM NPT
3/4 MH NPT
3/4 HH NPT
1 MM NPT
1 MH NPT
1 HH NPT 164 50.8 44.4 44.4 22 50
(50% HRA) 1 x 10
(50% HRA) 2.3 KV
5000
5000
4900
5000
5000
5000
5000
4400
4300
8/13/2019 C200_eng
12/12