C103-E094 Infrared Spectrophotometer Control Workstation Introduction to the Functions of LabSolutions IR
Printed in Japan 3655-10325-30AIT
C103-E094
Infrared Spectrophotometer Control Workstation
Introduction to the Functions of LabSolutions IR
Introduction to the Functions of LabSolutions IR
LabSolutions IR provides the following functions:
In addition, a variety of other convenient functions enables simple, reliable infrared analysis.
Next-Generation Workstation Designed for the Future
• Easily create simple macro programs
• Validation functions that comply with regulations from a variety of countries
• Identification test program with improved operability
• Advanced contaminant analysis program
LabSolutions IR Functions
Macro Functions P.4,5
• Optimal for periodic inspections! A function is included to display
the number of days until the next inspection.
• Function included to display the number of days of optical source/laser usage
• Automatic scaling during monitoring adopted
• Measurement time display function
Spectrum Measurements P.6,7
• Horizontal axis correction function added for ATR spectra
• Overlay functions, etc. to accommodate a variety of needs
Data Processing Functions P.8,9
• A rich standard database (12,000 spectra)
• Simple differential spectra calculation functions, etc.
Spectrum Searches P.10,11
• Photometric measurements
• Time course measurements (option)
• New infrared microscope software (AIMView) (option)
Other Convenient Functions P.14,15
Macro Functions Provide Automation and Labor-Savings
Network-Enabled Rich Libraries and a High-Performance Search Function
Network-Enabled
LabSolutions IR
Rich Libraries and
a High-Performance
Search Function
Macro Functions
Provide Automation and
Labor-Savings
A Wealth ofNew Functions
LabSolutions IR provides the following functions:
In addition, a variety of other convenient functions enables simple, reliable infrared analysis.
Next-Generation Workstation Designed for the Future
• Easily create simple macro programs
• Validation functions that comply with regulations from a variety of countries
• Identification test program with improved operability
• Advanced contaminant analysis program
LabSolutions IR Functions
Macro Functions P.4,5
• Optimal for periodic inspections! A function is included to display
the number of days until the next inspection.
• Function included to display the number of days of optical source/laser usage
• Automatic scaling during monitoring adopted
• Measurement time display function
Spectrum Measurements P.6,7
• Horizontal axis correction function added for ATR spectra
• Overlay functions, etc. to accommodate a variety of needs
Data Processing Functions P.8,9
• A rich standard database (12,000 spectra)
• Simple differential spectra calculation functions, etc.
Spectrum Searches P.10,11
• Photometric measurements
• Time course measurements (option)
• New infrared microscope software (AIMView) (option)
Other Convenient Functions P.14,15
Macro Functions Provide Automation and Labor-Savings
Network-Enabled Rich Libraries and a High-Performance Search Function
Network-Enabled
LabSolutions IR
Rich Libraries and
a High-Performance
Search Function
Macro Functions
Provide Automation and
Labor-Savings
A Wealth ofNew Functions
4 5LabSolutions IR
Analytical Data System for FTIR
Advanced Primary Functions with LabSolutions IR
The following presents functions that were unavailable with IRsolution software,
as well as more advanced functions.
Various measurements and postrun analysisprograms can be selected.
Various macro programs can be selected.
Launcher
Validation Programs Compliant with Various Countries' RegulationsIn addition to existing Japanese/European Pharmacopoeias and ASTM
compliance, the software is now compliant with the Chinese Pharmacopoeia.
Easy-to-Operate Identification Test ProgramUp to 20 compounds can be preregistered for rapid analysis. Test with
a simple mouse click for easier operation and reduced errors.
Food Additive Identification Test Program
An identification macro program for food additives has been newly
added. Simplify identification tests by using transmission/ATR spectra
included in the 8th edition of the Japanese Standards of Food
Additives, a standard library.
Advanced Contaminant Analysis ProgramThe data has been increased by 553 components in comparison to the
previous contaminant analysis program. Furthermore, Shimadzu
proprietary algorithms have been adopted to significantly increase the
accuracy of contaminant analysis.
These programs enable complete automation of routine work,
from measurements to data processing and printing.
User-Created Macro Programs
4 5LabSolutions IR
Analytical Data System for FTIR
Advanced Primary Functions with LabSolutions IR
The following presents functions that were unavailable with IRsolution software,
as well as more advanced functions.
Various measurements and postrun analysisprograms can be selected.
Various macro programs can be selected.
Launcher
Validation Programs Compliant with Various Countries' RegulationsIn addition to existing Japanese/European Pharmacopoeias and ASTM
compliance, the software is now compliant with the Chinese Pharmacopoeia.
Easy-to-Operate Identification Test ProgramUp to 20 compounds can be preregistered for rapid analysis. Test with
a simple mouse click for easier operation and reduced errors.
Food Additive Identification Test Program
An identification macro program for food additives has been newly
added. Simplify identification tests by using transmission/ATR spectra
included in the 8th edition of the Japanese Standards of Food
Additives, a standard library.
Advanced Contaminant Analysis ProgramThe data has been increased by 553 components in comparison to the
previous contaminant analysis program. Furthermore, Shimadzu
proprietary algorithms have been adopted to significantly increase the
accuracy of contaminant analysis.
These programs enable complete automation of routine work,
from measurements to data processing and printing.
User-Created Macro Programs
6 7LabSolutions IR
Analytical Data System for FTIR
Spectrum Measurement Window
Direct Measurements from Monitor Measurements
Background measurements/sample
measurements can be started
directly during monitor
measurements.
Automatic Scaling Enabled Even During Monitor MeasurementsThe peak is never cut off at the top of the window during
monitor measurements.
Display of Time Until Measurements FinishThe time remaining until measurements finish is displayed.
Self-Diagnosis Function Can Be Completely VisualizedVisualize instrument control using displays showing elapsed days of
light source and laser usage, and days remaining until the next
periodic inspection.
6 7LabSolutions IR
Analytical Data System for FTIR
Spectrum Measurement Window
Direct Measurements from Monitor Measurements
Background measurements/sample
measurements can be started
directly during monitor
measurements.
Automatic Scaling Enabled Even During Monitor MeasurementsThe peak is never cut off at the top of the window during
monitor measurements.
Display of Time Until Measurements FinishThe time remaining until measurements finish is displayed.
Self-Diagnosis Function Can Be Completely VisualizedVisualize instrument control using displays showing elapsed days of
light source and laser usage, and days remaining until the next
periodic inspection.
8 9LabSolutions IR
Analytical Data System for FTIR
Simple Comparisons of Overlaid Spectra #1This shows peaks in the specified area with intensity aligned by baseline and peak top.
Right-Click Menus
Simple Comparisons of Overlaid Spectra #2All spectra are automatically scaled within the displayed vertical axis range.
Data Processing WindowAdvanced ATR Correction FunctionTo approximate the ATR spectrum closely to the transmission
spectrum, the software has been equipped with simultaneous
correction processing for the horizontal and vertical axes.
Wavenumber-Wavelength Conversion Function for Horizontal Axis UnitsAs a conversion for horizontal axis units, an nm display has been added.
correction processing for the horizontal and vertical axes.
8 9LabSolutions IR
Analytical Data System for FTIR
Simple Comparisons of Overlaid Spectra #1This shows peaks in the specified area with intensity aligned by baseline and peak top.
Right-Click Menus
Simple Comparisons of Overlaid Spectra #2All spectra are automatically scaled within the displayed vertical axis range.
Data Processing WindowAdvanced ATR Correction FunctionTo approximate the ATR spectrum closely to the transmission
spectrum, the software has been equipped with simultaneous
correction processing for the horizontal and vertical axes.
Wavenumber-Wavelength Conversion Function for Horizontal Axis UnitsAs a conversion for horizontal axis units, an nm display has been added.
10 11LabSolutions IR
Analytical Data System for FTIR
Search Window More Convenient Differential Calculations with the DatabaseEnables searches with respect to differential spectra, simplifying mixed
compound analysis. Furthermore, the difference coefficient can be up to 0.001.
Selecting All/Deselecting All Improves Work EfficiencySelect of deselect the databases used for searches with a
single click.
Rich Shimadzu Standard Library with Approximately 12,000 SpectraShimadzu's proprietary standard database, which includes polymers, inorganic
compounds, additives, pharmaceuticals, and reagents, has been significantly expanded.
Existing Standard Library (approx. 1,500 spectra)+
LabSolutions IR Standard Library Package (approx. 10,000 spectra)
1. Basic polymers (1,136 spectra)
2. Surfactants (1,031 spectra)
3. Ichem polymers (complete set) (540 spectra)
4. Alcohols and phenols (2,350 spectra)
5. Esters (3,650 spectra)
6. Organic solvents (664 spectra)
7. Semiconductor-related substances (645 spectra)
8. Cellulose (5 spectra)
10 11LabSolutions IR
Analytical Data System for FTIR
Search Window More Convenient Differential Calculations with the DatabaseEnables searches with respect to differential spectra, simplifying mixed
compound analysis. Furthermore, the difference coefficient can be up to 0.001.
Selecting All/Deselecting All Improves Work EfficiencySelect of deselect the databases used for searches with a
single click.
Rich Shimadzu Standard Library with Approximately 12,000 SpectraShimadzu's proprietary standard database, which includes polymers, inorganic
compounds, additives, pharmaceuticals, and reagents, has been significantly expanded.
Existing Standard Library (approx. 1,500 spectra)+
LabSolutions IR Standard Library Package (approx. 10,000 spectra)
1. Basic polymers (1,136 spectra)
2. Surfactants (1,031 spectra)
3. Ichem polymers (complete set) (540 spectra)
4. Alcohols and phenols (2,350 spectra)
5. Esters (3,650 spectra)
6. Organic solvents (664 spectra)
7. Semiconductor-related substances (645 spectra)
8. Cellulose (5 spectra)
12 13LabSolutions IR
Analytical Data System for FTIR
Printing Window
Drag & Drop
Easy-to-Create Report FormatsCreate a flexible printing layout by simply
dragging and dropping layout items.
The Layout Is Evident at a GlanceItems that you drag and drop can be checked
without switching to print preview.
Adjustable LayoutFreely create your desired layout.
Examples are shown below.Peak Detection Layout Layout with Expanded View Insert Layout with Photograph Insert
12 13LabSolutions IR
Analytical Data System for FTIR
Printing Window
Drag & Drop
Easy-to-Create Report FormatsCreate a flexible printing layout by simply
dragging and dropping layout items.
The Layout Is Evident at a GlanceItems that you drag and drop can be checked
without switching to print preview.
Adjustable LayoutFreely create your desired layout.
Examples are shown below.Peak Detection Layout Layout with Expanded View Insert Layout with Photograph Insert
14 15LabSolutions IR
Analytical Data System for FTIR
* This software is packaged with the infrared microscope (AIM-8800).Example of Time Course Measurement for Vinyl Chloride Resin Adhesive
Example of Pass/Fail Judgment for Degree of Polymerization for Polypropylene/Polyethylene with Different Degrees of Polymerization (for Quality Control)
More Functions Available
Tracking Changes Over Time at Specified Wavenumbers (Photometric)Intensity (absorbance, transmittance, etc.), peak height, area, etc. can be scanned at specified wavenumbers.
The scanned values can be used for various calculations. Pass/fail judgments can be made from these values.
Tracking Changes Over Time for the Spectrum as a Whole (Time Course)You can measure the spectrum at set intervals, and track changes in specified peaks. Spectra and changes as a function of time can be
extracted from the time course data obtained. Reaction rates can also be calculated utilizing reaction peaks in the postrun analysis window.
Advanced Infrared Microscope Software (AIMView 2.00)*This software can coordinate with the LabSolutions IR spectrum measurement program to automatically measure specified positions (up
to 10 locations). The aperture size and shape can be set automatically, and images of the measurement position can be appended to
the measured spectra.
Measurement Position and Aperture Size Can Be Recorded
File name, background measurement frequency and other settings are extremely easy
Option
Arb.Units17.5
15.0
12.5
10.0
7.5
5.0
2.5
0.00 200 400 600 800 1000 1200 1400 1600 1800
Peak area near 1,708 cm-1
Peak area near 1,219 cm-1
Peak area near 609 cm-1
Set the pass/fail judgment standards, and then perform the measurements.
Automatic Display of Pass/Fail Judgments
14 15LabSolutions IR
Analytical Data System for FTIR
* This software is packaged with the infrared microscope (AIM-8800).Example of Time Course Measurement for Vinyl Chloride Resin Adhesive
Example of Pass/Fail Judgment for Degree of Polymerization for Polypropylene/Polyethylene with Different Degrees of Polymerization (for Quality Control)
More Functions Available
Tracking Changes Over Time at Specified Wavenumbers (Photometric)Intensity (absorbance, transmittance, etc.), peak height, area, etc. can be scanned at specified wavenumbers.
The scanned values can be used for various calculations. Pass/fail judgments can be made from these values.
Tracking Changes Over Time for the Spectrum as a Whole (Time Course)You can measure the spectrum at set intervals, and track changes in specified peaks. Spectra and changes as a function of time can be
extracted from the time course data obtained. Reaction rates can also be calculated utilizing reaction peaks in the postrun analysis window.
Advanced Infrared Microscope Software (AIMView 2.00)*This software can coordinate with the LabSolutions IR spectrum measurement program to automatically measure specified positions (up
to 10 locations). The aperture size and shape can be set automatically, and images of the measurement position can be appended to
the measured spectra.
Measurement Position and Aperture Size Can Be Recorded
File name, background measurement frequency and other settings are extremely easy
Option
Arb.Units17.5
15.0
12.5
10.0
7.5
5.0
2.5
0.00 200 400 600 800 1000 1200 1400 1600 1800
Peak area near 1,708 cm-1
Peak area near 1,219 cm-1
Peak area near 609 cm-1
Set the pass/fail judgment standards, and then perform the measurements.
Automatic Display of Pass/Fail Judgments
Printed in Japan 3655-10325-30AIT
C103-E094
Infrared Spectrophotometer Control Workstation
Introduction to the Functions of LabSolutions IR
Introduction to the Functions of LabSolutions IR