Top Banner
CO 2 CALIBRATION Sathish 06182013
32

C O 2 CALIBRATION Sathish 06182013. TEST 1 (200 SCCM ) Synthetic air 350 ppm Test gas 10 min.

Dec 18, 2015

Download

Documents

Dylan Fletcher
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: C O 2 CALIBRATION Sathish 06182013. TEST 1 (200 SCCM ) Synthetic air 350 ppm Test gas 10 min.

CO2 CALIBRATION

Sathish06182013

Page 2: C O 2 CALIBRATION Sathish 06182013. TEST 1 (200 SCCM ) Synthetic air 350 ppm Test gas 10 min.

TEST 1 (200 SCCM)

Synthetic air

350 ppm

Test gas

10 min

10 min

10 min

Page 3: C O 2 CALIBRATION Sathish 06182013. TEST 1 (200 SCCM ) Synthetic air 350 ppm Test gas 10 min.

RESULT

Page 4: C O 2 CALIBRATION Sathish 06182013. TEST 1 (200 SCCM ) Synthetic air 350 ppm Test gas 10 min.

TEST 2 (200 SCCM)

Synthetic air

Test gas

10 min

10 min

Page 5: C O 2 CALIBRATION Sathish 06182013. TEST 1 (200 SCCM ) Synthetic air 350 ppm Test gas 10 min.

TEST 2 RESULTS

Page 6: C O 2 CALIBRATION Sathish 06182013. TEST 1 (200 SCCM ) Synthetic air 350 ppm Test gas 10 min.

TEST 3 (500 SCCM)

Synthetic air

Test gas

10 min

10 min

Page 7: C O 2 CALIBRATION Sathish 06182013. TEST 1 (200 SCCM ) Synthetic air 350 ppm Test gas 10 min.

RESULT

Page 8: C O 2 CALIBRATION Sathish 06182013. TEST 1 (200 SCCM ) Synthetic air 350 ppm Test gas 10 min.

TEST 4 (200 SCCM)

Synthetic air

Test gas

Test gas

30 min

10 min

10 min

Page 9: C O 2 CALIBRATION Sathish 06182013. TEST 1 (200 SCCM ) Synthetic air 350 ppm Test gas 10 min.

RESULT

Page 10: C O 2 CALIBRATION Sathish 06182013. TEST 1 (200 SCCM ) Synthetic air 350 ppm Test gas 10 min.

TEST 5 (200 SCCM)

Synthetic air

Test gas

20 min

20 min

Page 11: C O 2 CALIBRATION Sathish 06182013. TEST 1 (200 SCCM ) Synthetic air 350 ppm Test gas 10 min.

RESULT

Page 12: C O 2 CALIBRATION Sathish 06182013. TEST 1 (200 SCCM ) Synthetic air 350 ppm Test gas 10 min.

WIND SPEED AND DIRECTION SENSOR

Page 13: C O 2 CALIBRATION Sathish 06182013. TEST 1 (200 SCCM ) Synthetic air 350 ppm Test gas 10 min.

Gill ultrasonic wind sensors are true solid-state devices

No need for regular maintenance, making them the ideal choice for a wide range of applications, particularly those in hostile environments.

Page 14: C O 2 CALIBRATION Sathish 06182013. TEST 1 (200 SCCM ) Synthetic air 350 ppm Test gas 10 min.

WIND OBSERVER

All Wind Observer sensors have an IP66 rated stainless steel construction.

The Wind Observer 65, 70 & 75 are available with a range of mounting and connection

Wind Observer IS has approval for use in hazardous petrochemical environments

Page 15: C O 2 CALIBRATION Sathish 06182013. TEST 1 (200 SCCM ) Synthetic air 350 ppm Test gas 10 min.

WIND OBSERVER 65

The Wind Observer 65 will monitor wind speeds up to 65m/s(145mph) and provides data via digital and optional analogue outputs.

This wind sensor is particularly suitable for use in land based and marine environments.

Page 16: C O 2 CALIBRATION Sathish 06182013. TEST 1 (200 SCCM ) Synthetic air 350 ppm Test gas 10 min.

DETAILS OF WIND OBSERVER 65

Wind Speed Range 65m/s (145mph) Construction Stainless Steel Operational Temp -55°C to +70°C Weight 1.4kg (50oz)

Page 17: C O 2 CALIBRATION Sathish 06182013. TEST 1 (200 SCCM ) Synthetic air 350 ppm Test gas 10 min.

WIND OBSERVER 70

The Wind Observer 70 will monitor wind speeds up to 70m/s (157mph) and has been accepted for service by the FAA and CAA for reporting of surface wind in airport applications

Page 18: C O 2 CALIBRATION Sathish 06182013. TEST 1 (200 SCCM ) Synthetic air 350 ppm Test gas 10 min.

DETAILS OF WIND OBSERVER 70

Wind Speed Range 70m/s (157mph) Construction Stainless Steel Operational Temp -55°C to +70°C Weight 1.4kg (50oz) Heating Option High Power

Page 19: C O 2 CALIBRATION Sathish 06182013. TEST 1 (200 SCCM ) Synthetic air 350 ppm Test gas 10 min.

WIND OBSERVER 75

The Wind Observer 75 will monitor wind speeds up to 75m/s (168mph) and features 150 Watts of electrical heating power in the anemometer head.

This sensor has been designed for use in freezing weather conditions

Page 20: C O 2 CALIBRATION Sathish 06182013. TEST 1 (200 SCCM ) Synthetic air 350 ppm Test gas 10 min.

DETAILS OF WIND OBSERVER 75

Wind Speed Range 75m/s (168mph) Construction Stainless Steel Operational Temp -55°C to +70°C Weight 1.4kg (50oz) Heating Option High Power

Page 21: C O 2 CALIBRATION Sathish 06182013. TEST 1 (200 SCCM ) Synthetic air 350 ppm Test gas 10 min.

PRINCIPLE OF OPERATION

Page 22: C O 2 CALIBRATION Sathish 06182013. TEST 1 (200 SCCM ) Synthetic air 350 ppm Test gas 10 min.

CONTINUE

Page 23: C O 2 CALIBRATION Sathish 06182013. TEST 1 (200 SCCM ) Synthetic air 350 ppm Test gas 10 min.

CONTINUE

Where as

L = Distance between the transducer faces . C = Speed of sound. V = Velocity of air flow. T1= Transit time of ultrasound T2= Transit time of ultrasound

Page 24: C O 2 CALIBRATION Sathish 06182013. TEST 1 (200 SCCM ) Synthetic air 350 ppm Test gas 10 min.
Page 25: C O 2 CALIBRATION Sathish 06182013. TEST 1 (200 SCCM ) Synthetic air 350 ppm Test gas 10 min.
Page 26: C O 2 CALIBRATION Sathish 06182013. TEST 1 (200 SCCM ) Synthetic air 350 ppm Test gas 10 min.

DUST SENSOR

Q_ bit (PM2.5 and PM10)

Baud rate 19200

Precise measures are reached after 4 minutes warm _ up time

Page 27: C O 2 CALIBRATION Sathish 06182013. TEST 1 (200 SCCM ) Synthetic air 350 ppm Test gas 10 min.

SENSOR SPECIFICATION

Page 28: C O 2 CALIBRATION Sathish 06182013. TEST 1 (200 SCCM ) Synthetic air 350 ppm Test gas 10 min.

BAROMETRIC PRESSURE SENSOR

Infineon (KP 254)

Page 29: C O 2 CALIBRATION Sathish 06182013. TEST 1 (200 SCCM ) Synthetic air 350 ppm Test gas 10 min.

PRODUCT DESCRIPTION

The KP254 is a miniaturized Digital Barometric Air Pressure Sensor IC based on a capacitive principle.

The sensor converts a pressure into a 10-bit digital value and sends the information via the SPI interface. In addition, a temperature sensor is integrated on chip.

Page 30: C O 2 CALIBRATION Sathish 06182013. TEST 1 (200 SCCM ) Synthetic air 350 ppm Test gas 10 min.

FEATURES

High accuracy pressure sensing (± 1.5 kPa) Real 10-bit pressure resolution Integrated temperature sensor Real 10-bit temperature resolution Self diagnosis features

Page 31: C O 2 CALIBRATION Sathish 06182013. TEST 1 (200 SCCM ) Synthetic air 350 ppm Test gas 10 min.

APPLICATIONS

Automotive applications Industrial control Consumer applications Medical applications Weather stations

Page 32: C O 2 CALIBRATION Sathish 06182013. TEST 1 (200 SCCM ) Synthetic air 350 ppm Test gas 10 min.

THANK YOU