  • 8/12/2019 C Node Presen3.0

    1/33

    NEC Corporation 2002

    SDD C-Node 20030203

    Confidential Information [ Disclosed/distributed to NEC and authorized customers only ]

    SpectralWave C-Node

    February 2003

    International Operations UnitNEC Corporation

  • 8/12/2019 C Node Presen3.0

    2/33

    NEC Corporation 2002 Confidential Information [ Disclosed/distributed to NEC and authorized customers only ]

    SDD C-Node 20030203

    What is the C-Node ?

    Overview

    Application Examples

    Specifications

    Contents

  • 8/12/2019 C Node Presen3.0

    3/33

    NEC Corporation 2002 Confidential Information [ Disclosed/distributed to NEC and authorized customers only ]

    SDD C-Node 20030203

    1. What is the C1. What is the C--Node ?Node ?

  • 8/12/2019 C Node Presen3.0

    4/33 NEC Corporation 2002 Confidential Information [ Disclosed/distributed to NEC and authorized customers only ]

    SDD C-Node 20030203

    SpectralWave C-Node is the Multi-Service Compact Node that supports

    STM-1, STM-4, 2M, 34M, 45M and Fast Ethernet.

    SpectralWave C-Node supports wide variety of network Applicationsincluding mobile network, data communication network, enterprise

    intranet and so on.

    What is the CWhat is the C--Node ?Node ?

    *SpectralWave : The trade-mark of NECs optical

    network products

    *C-Node : The name C-Node means Compact Node

    and appeals its compactness and

    economical benefit.

  • 8/12/2019 C Node Presen3.0

    5/33 NEC Corporation 2002 Confidential Information [ Disclosed/distributed to NEC and authorized customers only ]

    SDD C-Node 20030203

    Applicable Area of the CApplicable Area of the C--NodeNode

    STM-16/64 Ring

    U-Node

    U-Node

    U-Node

    C-Node

    Backbone/Metro Area Business Access Area

    STM-1/4

    Point-to-Point

    connection

    Multi-ring connectionSTM-4 Ring connection

    STM-1 Ring

    connection

    10M or 100MEther

    C-Node

    2M

    PBX

    2M

    C-Node

    45M, 34M

    STM-1/4Linear busconnection

    C-Node 10M or 100MEther

    C-Node

    2MC-Node C-Node

    Micro-link connection

    NMS

    C-Node

    C-Node

    NECAPEX3000

    NECAPEX3000

  • 8/12/2019 C Node Presen3.0

    6/33 NEC Corporation 2002 Confidential Information [ Disclosed/distributed to NEC and authorized customers only ]

    SDD C-Node 20030203

    FeaturesFeatures

    FlexibleFlexibleFlexible

    Supporting of Various Tributary Interface

    STM-1, STM-4, 2M, 34M, 45M, 10Base-T and 100Base-Tx

    Supporting of Various Network TopologiesPoint-to-Point, Linear, Ring, Multiple Ring

    Upgradeable from STM-1 to STM-4 system

    Flexible and Scalable Network Design

    Seamless Network ManagementSeamless Network ManagementSeamless Network Management

    End-to-End Path Creation using Integrated

    Network Management System

    CompactCompactCompact

    Rack Mount (19inch) and Wall mount

    2U size in 19 inch rack

  • 8/12/2019 C Node Presen3.0

    7/33 NEC Corporation 2002 Confidential Information [ Disclosed/distributed to NEC and authorized customers only ]

    SDD C-Node 20030203

    2. Overview2. Overview

  • 8/12/2019 C Node Presen3.0

    8/33 NEC Corporation 2002 Confidential Information [ Disclosed/distributed to NEC and authorized customers only ]

    SDD C-Node 20030203

    (1) Point(1) Point--toto--PointPoint (2) Linear(2) Linear

    (3) Ring (SNCP)(3) Ring (SNCP) (4) Multi(4) Multi--Ring (SNCP)Ring (SNCP)

    Network TopologiesNetwork Topologies

    Terminal TerminalTerminal Terminal

    Working

    Protection* Only working is possible in the case of STM-4

    Linear ADM

    Working

    Protection *

    Working

    Protection *

    STMSTM--1/41/4

    RingRing

    Protection

    Working STMSTM--44

    RingRing

    STMSTM--11

    RingRing

    Protection

    Protection

    Working

    Working

  • 8/12/2019 C Node Presen3.0

    9/33 NEC Corporation 2002 Confidential Information [ Disclosed/distributed to NEC and authorized customers only ]

    SDD C-Node 20030203

    Various Interface TypesVarious Interface Types

    Physical InterfacesSTM-4 : S-4.1,L-4.1,L-4.2

    STM-1 : S-1.1,L-1.1,L-1.2, Electrical

    PDH : 2M, 34M, 45M

    Fast Ethernet : 10Base-T,100Base-TX

    VC Multiplexing StructureVCVC--44 TUGTUG--33 TUGTUG--22 TUTU--1212 VCVC--1212 2M2M

    VCVC--44 TUGTUG--33 TUTU--33 VCVC--33 34M34M

    VCVC--44 TUGTUG--33 TUTU--33 VCVC--33 45M45M

    VCVC--44

    TUGTUG--33

    TUGTUG--22

    TUTU--1212

    VCVC--1212--XvXv

    10/100Base10/100Base--TxTx

  • 8/12/2019 C Node Presen3.0

    10/33

    NEC Corporation 2002 Confidential Information [ Disclosed/distributed to NEC and authorized customers only ]

    SDD C-Node 20030203

    System Configuration (1) PointSystem Configuration (1) Point --toto--PointPoint

    STMSTM--1 1+1 MSP1 1+1 MSP

    C-Node

    2M x 8

    FE x 4

    STM-1W

    2M x 8

    FE x 4 BLANK

    STM-1o x 2BLANK

    C-Node

    P

    FE: Fast Ethernet: 10Base-T,100Base-TX

    S C fi i (2) Li

  • 8/12/2019 C Node Presen3.0

    11/33

    1 NEC Corporation 2002 Confidential Information [ Disclosed/distributed to NEC and authorized customers only ]

    SDD C-Node 20030203

    C-Node

    2M x 8

    FE x 4

    STM-1W

    STM-1o x 2

    FE x 4 BLANK

    STM-1o x 22M x 8

    C-Node C-Node

    W

    P P

    STM-1

    System Configuration (2) Linear

    STM-1 1+1 MSP

    FE: Fast Ethernet: 10Base-T,100Base-TX

    S t C fi ti (3) M ltiS t C fi ti (3) M lti RiRi

  • 8/12/2019 C Node Presen3.0

    12/33

    1 NEC Corporation 2002 Confidential Information [ Disclosed/distributed to NEC and authorized customers only ]

    SDD C-Node 20030203

    System Configuration (3) MultiSystem Configuration (3) Multi --RingRing

    STMSTM--4 SNCP + STM4 SNCP + STM--1 SNCP1 SNCP

    STM-1o x 2

    FE x 4 2M x 32

    STM-4 x 2

    2M x 32

    STM-4

    STM-1

    2M x 63ch

    FE x 4

    C-Node

    C-Node

    C-Node

    C-Node

    C-Node C-Node

    C-NodeFE: Fast Ethernet: 10Base-T,100Base-TX

  • 8/12/2019 C Node Presen3.0

    13/33

    1 NEC Corporation 2002 Confidential Information [ Disclosed/distributed to NEC and authorized customers only ]

    SDD C-Node 20030203

    Interface Configuration (150M Type )Interface Configuration (150M Type )

    * Symbol indicates Slot that module/board can be installed in

    SUB SLOT 1SUB SLOT 2 SUB SLOT 4

    MAIN SLOTSUB SLOT 3

    Note: Table shows the configuration in maximum

    installation

    East West

    Up to 2STM-1e x 1 module

    Up to 2STM-1o x 1 module

    WEST

    Maximum

    Number

    SLOT4SLOT3SLOT2SLOT1MAIN

    Up to 4

    Up to 1

    Up to 1

    Up to 3

    Up to 4

    Up to 4

    Up to 4

    Up to 2

    Up to 2

    2M x 8 / board

    STM-1o x 2 / board

    STM-1e x 2 / board

    10/100Base-T x 4 / board

    45M x 3 / board

    34M x 3 / board

    2M x 32 / board

    STM-1e x 1 / board

    STM-1o x 1 / board

    EAST

  • 8/12/2019 C Node Presen3.0

    14/33

    1 NEC Corporation 2002 Confidential Information [ Disclosed/distributed to NEC and authorized customers only ]

    SDD C-Node 20030203

    Interface Configuration (600M Type )Interface Configuration (600M Type )

    SUB SLOT 1SUB SLOT 2 SUB SLOT 4

    MAIN SLOTSUB SLOT 3

    Note: Table shows the configuration in maximum

    installation

    * Symbol indicates Slot that module can be installed in

    East West

    Up to 2STM-4 x 1 / board

    Up to 2STM-1e x 1 module

    Up to 2STM-4 x 1 module

    Up to 2STM-1o x 1 module

    WEST

    Maximum NumberSLOT4SLOT3SLOT2SLOT1MAIN

    Up to 4

    Up to 4

    Up to 4

    Up to 4

    Up to 4

    Up to 4

    Up to 4

    Up to 4

    Up to 4

    10/100Base-T x 4 / board

    2M x 8 / board

    STM-1o x 2 / board

    STM-1e x 2 / board

    45M x 3 / board

    34M x 3 / board

    2M x 32 / board

    STM-1e x 1 / board

    STM-1o x 1 / board

    EAST

  • 8/12/2019 C Node Presen3.0

    15/33

    1 NEC Corporation 2002 Confidential Information [ Disclosed/distributed to NEC and authorized customers only ]

    SDD C-Node 20030203

    Upgrade STMUpgrade STM--1 System1 System STMSTM--4 System4 System

    Capacity UpgradeCapacity Upgrade

    Tributary Interface

    2M : Max. 63ch(two SUB boards)

    at Center node in STM-1 Ring

    Tributary Interface

    2M : Max. 128ch(four SUB boards)

    at Center node in STM-4 Ring

    Upgrade by Adding/Replacing of Module (replacing of InterfaceUpgrade by Adding/Replacing of Module (replacing of Interface

    module, adding Matrix submodule, adding Matrix sub--module)module)

    STM-1

    (WEST)

    STM-1

    (EAST)

    STM-1

    SUB boardSUB board

    SUB board SUB board

    STM-4

    (WEST)

    STM-4

    (EAST)

    STM-4SUB boardSUB board

    SUB board SUB board

    Extended

    XC

    AddAdd ReplaceReplace

  • 8/12/2019 C Node Presen3.0

    16/33

    1 NEC Corporation 2002 Confidential Information [ Disclosed/distributed to NEC and authorized customers only ]

    SDD C-Node 20030203

    Small Start for Cost-Effective

    Flexible and Scalable Network Design

    Flexible Expandabil ity according to

    Customer Traffic Demand

    Flexible and Scalable Network DesignFlexible and Scalable Network Design

    Supporting Various Interface Types

    Supporting Wide Variety of Network Topologies

    Flexibili ty of Installing Tributary INF

    Upgrade STM-1 System to STM-4 System

  • 8/12/2019 C Node Presen3.0

    17/33

    1 NEC Corporation 2002 Confidential Information [ Disclosed/distributed to NEC and authorized customers only ]

    SDD C-Node 20030203

    Ethernet Connection Mechanism (1/2)Ethernet Connection Mechanism (1/2)

    For Ethernet traffic, incoming signal from client is shaped in bandwidth ofVC-12 x n and mapped into VC-12 x n paths of network side.

    SpectralWave C-Node has two types of Ethernet Interface

    10/100BaseT Board (four WAN port),

    10/100Base-T2 Board (two WAN port)

    10/100Base-TNo. of 10/100Base-T port: 4No. of WAN port: 4Encapsulation: GFP, LAPSConcatenation Level: VC-12-Xv ( X=1, 2, 3, 21 / Port)

    10/100Base-T2No. of 10/100Base-T port: 4

    No. of WAN port: 2

    Encapsulation: LAPS

    Concatenation Level: VC-12-Xv ( X=1, 2, 3, 16 / Port)

  • 8/12/2019 C Node Presen3.0

    18/33

    1 NEC Corporation 2002 Confidential Information [ Disclosed/distributed to NEC and authorized customers only ]

    SDD C-Node 20030203

    Ethernet Connection Mechanism (2/2)Ethernet Connection Mechanism (2/2)

    10/100BASE-T2

    (2 WAN port)

    L2 SW (Mac Bridge) L2 SW (Mac Bridge)

    VC-12-Xv

    (X=1 to 16 / port)

    VC-12-Xv

    (X=1 to 21 / Port)

    STM-1/ 4

    (East)

    STM-1/ 4

    (West)

    10/100BASE-T

    (4 WAN port)

    Framing (LAPS) Framing (GFP / LAPS)

    Virtual Concatenation Virtual Concatenation

    POH Termination POH Termination

    Crossconnect

    PHY PHY

    WAN port

    (two)

    WAN port

    (four)

  • 8/12/2019 C Node Presen3.0

    19/33

    1 NEC Corporation 2002 Confidential Information [ Disclosed/distributed to NEC and authorized customers only ]

    SDD C-Node 20030203

    Layer 2 Switch FunctionLayer 2 Switch Function

    IEEE 802.1D Relay Entity

    Mac Forwarding, Mac Learning

    VLANPort VLAN

    Tag VLAN

    Prioritization IEEE 802.1D Spanning Tree Protocol

    IEEE 802.3X Flow Control

  • 8/12/2019 C Node Presen3.0

    20/33

    1 NEC Corporation 2002 Confidential Information [ Disclosed/distributed to NEC and authorized customers only ]

    SDD C-Node 20030203

    Various Synchronization SourceVarious Synchronization Source

    C-Node supports various synchronization sources

    STM-N Line, 2M(120 or 75ohm) Tributary,

    2M(only 75ohm) External Clock(single input/output)

    Providing more reliable synchronization network !

    STM-N STM-N

    External Clock ports can be configured both in Main board and FAN unit

    2M External clock input / output2M Tributary

  • 8/12/2019 C Node Presen3.0

    21/33

    2 NEC Corporation 2002 Confidential Information [ Disclosed/distributed to NEC and authorized customers only ]

    SDD C-Node 20030203

    TCP/IP NW

    Integrated Network Management (INCIntegrated Network Management (INC--100MS)100MS)

    C-Node U-NodeBBM U-NodeBBM

    C-Node

    C-Node C-Node

    End-to-end path provisioningto managed NEs

    Server

    PC Clients

    Reporting of alarm and

    performance information

    Multi-Server configurationfor large network

    (up to 4,096 NEs

    @16 servers)

    GUI for end-to-end path creationINC-100MS (NMS/EMS)

    Intelligent and sophisticated total network management

  • 8/12/2019 C Node Presen3.0

    22/33

    2 NEC Corporation 2002 Confidential Information [ Disclosed/distributed to NEC and authorized customers only ]

    SDD C-Node 20030203

    Management of CManagement of C--Node using CID (Craft Interface Device)Node using CID (Craft Interface Device)

    C-Node

    C-Node

    C-Node

    C-Node

    Remote Access throughSDH overhead (DCCr)

    10Base-T

    Cross-Connect setupUser Login

    Windows OS

    Complete management functions at element level- Fault management

    - Performance management

    - Configuration management

    - Security management

    A

  • 8/12/2019 C Node Presen3.0

    23/33

    2 NEC Corporation 2002 Confidential Information [ Disclosed/distributed to NEC and authorized customers only ]

    SDD C-Node 20030203

    AppearanceAppearanceFront View

    Front View

    482mm300mm

    88mm

    It is possible to install in 19 inch

    Rack (2U size)

    Front Access

    I t ll tiI t ll ti

  • 8/12/2019 C Node Presen3.0

    24/33

    2 NEC Corporation 2002 Confidential Information [ Disclosed/distributed to NEC and authorized customers only ]

    SDD C-Node 20030203

    InstallationInstallation

    Wall MountRack MountBracket

    19 inch

    Shelf Support

  • 8/12/2019 C Node Presen3.0

    25/33

    2 NEC Corporation 2002 Confidential Information [ Disclosed/distributed to NEC and authorized customers only ]

    SDD C-Node 20030203

    3. Application Examples3. Application Examples

    Application (1)Application (1)

  • 8/12/2019 C Node Presen3.0

    26/33

    2 NEC Corporation 2002 Confidential Information [ Disclosed/distributed to NEC and authorized customers only ]

    SDD C-Node 20030203

    STMSTM--1 or STM1 or STM--44

    Company ACompany A

    Company BCompany B

    pp ca o ( )pp ( )

    Enterprise Dedicated Line Service (Enterprise Dedicated Line Service (PtoPPtoP))

    Service Interfaces2Mbps

    45Mbps

    34Mbps

    155Mbps

    10Base-T100Base-Tx

    Router,

    L2/3 SW

    PBX PBX

    NECAPEX3000

    NECAPEX3000

    NECAPEX3000

    NECAPEX3000

    Router,

    L2/3 SW

    C-Node C-Node

    Application (2)Application (2)

  • 8/12/2019 C Node Presen3.0

    27/33

    2 NEC Corporation 2002 Confidential Information [ Disclosed/distributed to NEC and authorized customers only ]

    SDD C-Node 20030203

    U-Node

    Company A

    Company A

    Company C

    Company B Company CCompany B

    STMSTM--16/64 Ring16/64 Ring

    STMSTM--11RingRing

    Service Interfaces

    2Mbps

    45Mbps

    34Mbps

    155Mbps10Base-T

    100Base-Tx

    STMSTM--11

    RingRing

    STMSTM--4 Ring4 RingC-Node

    C-Node

    C-Node

    C-Node

    C-Node

    C-Node

    C-Node

    U-Node

    U-Node

    Application (2)Application (2)

    Enterprise Dedicated Line Service (Ring)Enterprise Dedicated Line Service (Ring)

    Application (3)

  • 8/12/2019 C Node Presen3.0

    28/33

    2 NEC Corporation 2002 Confidential Information [ Disclosed/distributed to NEC and authorized customers only ]

    SDD C-Node 20030203

    pp ( )

    Mixing Network with Micro Link

    Microwave

    STM-1o/e STM-1o/e

    STM-1o STM-1o

    Company A

    Company A

    C-Node

    C-Node

    C-Node

    C-Node

    STMSTM--11

    Ring

    Service Interfaces

    2Mbps

    45Mbps

    34Mbps

    155Mbps10Base-T

    100Base-T

    Application (4)Application (4)

  • 8/12/2019 C Node Presen3.0

    29/33

    2 NEC Corporation 2002 Confidential Information [ Disclosed/distributed to NEC and authorized customers only ]

    SDD C-Node 20030203

    pp ( )( )

    Mobile Network ServiceMobile Network Service

    BTS

    BTS

    BTS

    BTS

    BTS

    STM-1/4

    Access Ring

    STM-1/4

    Access Ring

    STM-1/4 LinearService Interfaces

    2Mbps

    BSC

    BTS

    C-NodeC-Node

    C-Node

    C-Node

    C-Node

    C-Node

    C-Node

    C-Node

    C-Node

    STMSTM--16/6416/64

    RingRing

    BTS: Base Transceiver Station

    BSC: Base Station Controller

    U-Node

    U-Node

    U-Node

    U-Node

    BTS

    Application (4)Application (4)

  • 8/12/2019 C Node Presen3.0

    30/33

    2 NEC Corporation 2002 Confidential Information [ Disclosed/distributed to NEC and authorized customers only ]

    SDD C-Node 20030203

    ( )

    Mobile Network ServiceMobile Network Service

    BTS

    BTS

    BTS

    BTS

    BTS

    STM-1/4

    Access Ring

    STM-1/4

    Access Ring

    STM-1/4 LinearService Interfaces

    2Mbps

    BSC

    BTS

    BTS

    C-NodeC-Node

    C-Node

    C-Node

    C-Node

    C-Node

    C-Node

    C-Node

    C-Node

    U-Node

    U-Node

    U-Node

    U-Node

    STMSTM--16/6416/64

    RingRing

    BTS: Base Transceiver Station

    BSC: Base Station ControllerCompany A Company A

    Ethernet Leased Line

  • 8/12/2019 C Node Presen3.0

    31/33

    3 NEC Corporation 2002 Confidential Information [ Disclosed/distributed to NEC and authorized customers only ]

    SDD C-Node 20030203

    4. Specifications4. Specifications

    SpecificationsSpecifications

  • 8/12/2019 C Node Presen3.0

    32/33

    3 NEC Corporation 2002 Confidential Information [ Disclosed/distributed to NEC and authorized customers only ]

    SDD C-Node 20030203

    SpecificationsSpecifications

    SpectralWave C-Node 150M Type SpectralWave C-Node 600M Type

    STM-4 (S-4.1, L-4.1, L-4.2) - Max 4ch

    STM-1 (S-1.1, L-1.1, L-1.2) Max 8ch Max 10ch

    STM-1e Max 8ch Max 10ch

    45M Max 6ch Max 12ch

    34M Max 6ch Max 12ch2M (75 or 120 ohms) Max 96ch Max 128ch

    10/100 Base-T Max 16ch Max 16ch

    VC-4 8 x 8 16 x 16

    VC-12 504 x 504 1,008 x 1,008

    Network Management Protcol

    35W (STM-1 x 2ch, 2M x 32ch) 40W (STM-4 x 2ch, 2M x 32ch)

    Redundancy

    Syncronizaton

    Items

    Interface

    Crossconnect Capacity

    Aggregate/

    Tributary

    Tributary

    Other Functions

    Dimension

    Operation Temperature

    STM-N Line, 2Mbps PDH Line, Internal Free run, Internal Holdover

    External CLK in/out (2Mbps or 2MHz selectable, 75ohms)

    Power Supply

    Power Comsumption

    1+1 Linear MSP, SNCP

    TCP/IP

    ITU-T G.826

    Orderwire (E1), User Channel (F1):V.11, HKC 4ch, HKA 8ch

    482 (W) x 88 (H) x 300 (D) (mm)

    0

    0

    C ~ 45

    0

    C-36 ~ -72V DC

    Performance Monitoring

  • 8/12/2019 C Node Presen3.0

    33/33

    3 NEC Corporation 2002 Confidential Information [ Disclosed/distributed to NEC and authorized customers only ]

    SDD C-Node 20030203

    Thank you very much for your interestThank you very much for your interest

    in NEC transport solutionin NEC transport solution