Top Banner
Operating Range: - Max viscosity 200cSt - Max system pressure 16BAR - Flow up tp 140 m3/h - Head up to 36m -Temperature Range for PFA/PP from -5 to +80°C - Temperature Range for PFA/PVDF from -35 to +100°C - Electric motors from 1,5 to 18.5KW - ATEX II - /3G cbk II C T5 S I S etting nnovative tandards The best solution for moving highly corrosive liquids, difficult to seal fluids and high purity C MAG-PL HORIZONTAL SEALLESS LINED CENTRIFUGAL MAGNETIC DRIVE PUMP, NO MECHANICAL SEAL Data for reference only. Parameters not associated Via dell’artigianato, 120 45015 Corbola (RO) Italy Tel: +39 0426346304 Fax: +39 0426349126 M PUMPS PROCESS s.r.l
6

C MAG-PL 2016 · 2018. 12. 30. · Operating Range: - Max viscosity 200cSt - Max system pressure 16BAR - Flow up tp 140 m3/h - Head up to 36m-Temperature Range for PFA/PP from -5

Aug 21, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: C MAG-PL 2016 · 2018. 12. 30. · Operating Range: - Max viscosity 200cSt - Max system pressure 16BAR - Flow up tp 140 m3/h - Head up to 36m-Temperature Range for PFA/PP from -5

Operating Range:

- Max viscosity 200cSt

- Max system pressure 16BAR

- Flow up tp 140 m3/h

- Head up to 36m

-Temperature Range for PFA/PP from -5 to +80°C

- Temperature Range for PFA/PVDF from -35 to +100°C

- Electric motors from 1,5 to 18.5KW

- ATEX II - /3G cbk II C T5

S I Setting nnovative tandards

The best solution for moving highly corrosive liquids, difficult to seal fluids and high purity

C MAG-PLHORIZONTAL SEALLESS LINED

CENTRIFUGAL MAGNETIC DRIVE PUMP,

NO MECHANICAL SEAL

Data for reference only. Parameters not associated

Via dell’artigianato, 120

45015 Corbola (RO) Italy

Tel: +39 0426346304

Fax: +39 0426349126

M PUMPS PROCESS s.r.l

Page 2: C MAG-PL 2016 · 2018. 12. 30. · Operating Range: - Max viscosity 200cSt - Max system pressure 16BAR - Flow up tp 140 m3/h - Head up to 36m-Temperature Range for PFA/PP from -5

RWP QUICK CARTRIDGE KIT to guarantee an easy and fast maintenance, materials PP and PVDF.

Epoxy primer and polyacrylic enamel water-based painting for the best chemical resistance against corrosion

O ring sealing system to avoid leakages to the atmosphere-different materials available:

- EPDM®- VITON

- FEP

Drain Plug for safe release of hazardous fluids or for flushing and monitoring.

One single piece PFA front casing liner firmly anchored onto outer Ductile Iron shell to withstand piping loads, high system pressure and vacuum conditions. Transfer moulding technology assures constance of 5 mm thickness in PFA lining.

P u m p D e t a i l s Succ ess ful Instal lations

Transfer of Hydrofluoric Acid, Nitric Acid and Phosphoric Acid in a Germany based Fine Chemical Plant

C MAG-PL50 installed into Fiscal Sampling Systems for the oil and gas.

Bekaert China application for waste water transferring

C MAG-PL80 applied for truck unloading of H2SO4 at 96% concentration

Page 3: C MAG-PL 2016 · 2018. 12. 30. · Operating Range: - Max viscosity 200cSt - Max system pressure 16BAR - Flow up tp 140 m3/h - Head up to 36m-Temperature Range for PFA/PP from -5

Application Fields:- Fine Chemical Industry. - Petrochemical Industry- Semi-Conductor Industry- Power Plant- Pulp and Paper Industry- Recycling Industry - Plating Industry

- Chemcical Industry- PCB Industry- Waster Water Industry- Pharmaceutical Industry- Galvanizing Industry- Plating Industry

Double shell design with signle piece primary shell made of thermoplastic materials , in PP GFR, PVDF CFR.Zero magnetic losses. No Eddy current lost, no waste of

Totally encapsulated high power synchronous magnetic coupling with magnetic elements being mechanically locked. Insure the magnetic elments retain its position under unfavourable atmospheric conditions.Magnetic elements are dislodged on conventional glue system when operating in corrosive and high heat environment which

Shaft is frmly supported by front casing shaft support and rear casing support which design for handling high radial load and eradicate shaft defection. Over size front and rear thrust bearings design for handling high axial load.Field assembling of the product lubricated bearing arrangement does not require special tools.The Shaft/ Bearing materials are available in three different configurations to provide the best solution each specific application:

- PTFEC – ALLUMINA 99,7% (standard);- CARBON – ALLUMINA 99,7%,- Silicon Carbide (SSIC) - Silicon Carbide (SSIC).

P u m p C o d i f i c a t i o n

34 NEMA 143 TC

40 NEMA 184 TC38 NEMA 182 TC36 NEMA 145 TC

42 NEMA 213 TC44 NEMA 215 TC

Page 4: C MAG-PL 2016 · 2018. 12. 30. · Operating Range: - Max viscosity 200cSt - Max system pressure 16BAR - Flow up tp 140 m3/h - Head up to 36m-Temperature Range for PFA/PP from -5

P u m p P e r f o r m a n c e s

3500 RPM2900 RPM

C MAG-PL50

HE

AD

[m

]

FLOW [US GPM]

PO

WE

R [kW

]

PO

WE

R [H

P]

NP

SH

r [m

]

NP

SH

r [ft]

HE

AD

[ft]

3FLOW [m /h]

HE

AD

[m

]

FLOW [US GPM]

PO

WE

R [kW

]

PO

WE

R [H

P]

NP

SH

r [m

]

NP

SH

r [ft]

HE

AD

[ft]

3FLOW [m /h]

40

35

20

25

30

15

10

5

4

5

32

3.0

3.5

2.5

2.0

1.5

1.0

0.50 5 10 15 20 25 30 35 40

1

2

3

4

5

10

15

20

40

60

80

100

120

14040200 60 80 100 120 140 160 180

0 40 80 120 160 200

40

20

10

30

0

6

4

2

4

1

2

3

5

20100 30 40 50

2

3

4

6

5

7

105

0

1520

60

40

80

100

120

140

3500 RPM2900 RPM

C MAG-PL65

HE

AD

[m

]

FLOW [US GPM]

PO

WE

R [kW

]

PO

WE

R [H

P]

NP

SH

r [m

]

NP

SH

r [ft]

HE

AD

[ft]

3FLOW [m /h]

0 100 200 300 400 500 600 70060

50

40

30

20

10

0

86420

25

20

15

10

50 20 40 60 80 100 120 140 160

20

15

10

25

30

35

10

20

30

0

0

20

40

60

80

100

120

140

160

180

3500 RPM2900 RPM

C MAG-PL80

PO

WE

R [H

P]

HE

AD

[m

]

FLOW [US GPM]

PO

WE

R [kW

]N

PS

Hr

[m]

NP

SH

r [ft]

HE

AD

[ft]

3FLOW [m /h]

0 50 100 150 200 250 300 350 400 500

20

40

60

80

100

120

140

160

180

5

10

20

30

40

50

234567

5

7

9

11

13

15

3

0 20 30 40 50 60 70 80 90 100 11010

10

15

20

25

101214161820

68

3500 RPM2900 RPM

C MAG-PL100

STD Version (PTFE-Alumina) Up to 5 min. NOT FREQUENTLY

- SPECIAL DRY RUNNING Version (Carbon-Sic) Up to 1 hour

- SPECIAL FO NOT FREQUENTLY If diamond coating Up to 30 min (on request).

R SOLID Version (Full Sic) Up to 1 min.

Solid handling capability

- STD Version (PTFE-Alumina) Solids up to 3%, particles up to 2 mm.

- HYDRAULIC BARRIER Version Solids up to 30%, particles up to 3* mm.

*Depend on each application, please contact M PUMPS

Dry running capability

Guideline for C MAG-PL Pumps series

Note: The present chart is referred to Dry running with residual liquid into the pump.

Dry Running Capability Chart

DRY RNING Ver Ca

- i ) - 3000 P

UN s. ( rbon S C

R MSTD. Vers. (PTFEC - Alumina) - 3000 RPM

D

NG

a-

3

RY RUNNI Vers. (C

rbon SiC) - 600 RPMSTD. Vers. (PTFEC - Alumina) - 3600 RPM

Vers.for solid (Full SiC) - 3600 RPM

Vers.for solid (Full SiC) - 3000 RPM

0 5 10 15 20 25 30t [ min ]

0 5 10 15 20 25 30t [ min ]

Page 5: C MAG-PL 2016 · 2018. 12. 30. · Operating Range: - Max viscosity 200cSt - Max system pressure 16BAR - Flow up tp 140 m3/h - Head up to 36m-Temperature Range for PFA/PP from -5

Temperature Limits

-35 -20 0 20 40 60 80 100 120

O u t l i n e d i m e n s i o n s

2 Poles motor

Pump Model

Motor size [IEC]

Motor power [kW]

A B C D E F G H I L M N O P

Q R Pump Kg

less motor

Baseplate Kg

Motor Kg **PN 16 ANSI

150#PN 16 ANSI

150#

C MAG-PL 50

90 2.2

149

267

84

184 210 57 106

21

200

62.5

105

180

13

11 50 2" 40 1" 1/2

23.5

22.5

53

100 / 112

3 / 5.5 277 194 220 53 120 250 135 15 27.5 70

C MAG-PL 65

100 / 112

3 / 5.5

172

321

103

218 250 80 100

38

250

73

135

210

15

14 65 3" 50 2"

37

27

70

132 7.5 341 238 250 80 120 300 153 15 38.5 106

C MAG-PL 80 132 7.5 198 368 121 247 250 89 120

38

300 82 153 210 15 14 80 4" 65 3" 46 34 106

C MAG-PL 100 160 18.5 227 409 129 280 290 93 150 350 102 180 250 20 14 100 4" 80 3" 56 51 173

Q

R

BC D

A

F G H

I

M

NE

O

N°4 Holes F PDrain portLiquid sensor(on request)

Vibration probe (on request)

L

Q

R

BC D

A

I

M

Vibration probe (on request)

L

O

F

G

H NE

P

*: depend on the motor manufacturer**: for reference only

Page 6: C MAG-PL 2016 · 2018. 12. 30. · Operating Range: - Max viscosity 200cSt - Max system pressure 16BAR - Flow up tp 140 m3/h - Head up to 36m-Temperature Range for PFA/PP from -5

How to protect your pump

•It detects process inefficiency.Early warnings allow you to takepreventive action.

•It protects pumps and other equipmentagainst damage

•It measure shaft power output and usesthe motor as a sensor.

•The result is reduced maintenanceand installation costs, extendedequipment lifetime and increasedreliability.

Emotron M20 Technical data

•Supply voltage 100-240 VAC / 380-500 VAC / 525-690 VAC

•Frequency 50 Hz / 60 Hz

•Rated current Up to 999 Avia current transformer

•Protection class IP20

•Approvals CE, UL, cUL

7) Closed coupled version reduces installation cost, , small footprint requirements.

superb permeation resistance.

2) Transfer moulding technology assures homogeneity of 5mm thickness in PFA lining that offers

1) Single stage, PFA lined , PP / PVDF wetted parts, in-between supported closed impeller,

magnetic drive centrifugal pump.

3) Vacuum Proof by unique technique of anchoring PFA lining onto the pump casing.

4) One piece solid machined impeller with no metal insert.

5) Module designed allows quick changing of parts and minimum stock.

6) Separate Impeller and internal magnet allows individual component replacement.

Design and Features

1750 RPM1450 RPM

C MAG-PL100

HE

AD

[m

]

FLOW [US GPM]

PO

WE

R [kW

]

PO

WE

R [H

P]

NP

SH

r [m

]

NP

SH

r [ft]

HE

AD

[ft]

3FLOW [m /h]

0 10 20 30 40 50 60 70 80

2

1.5

1

2.5

3

3.5

0 50 100 150 200 250 300 350

2.75

2.25

1.75

1.25

0.75

43210 0

5

10

150

5

10

15

20

25

30

35

40

45

0

2.5

5

7.5

10

12.5

15

1750 RPM1450 RPM

HE

AD

[m

]

FLOW [US GPM]

PO

WE

R [kW

]

PO

WE

R [H

P]

NP

SH

r [m

]

NP

SH

r [ft]

HE

AD

[ft]

3FLOW [m /h]

C MAG-PL80

3

5

7

9

11

13

0 50 100 150 200 250 300 350

0

2

1

0 10 20 30 40 50 60 70 80

0

4

3

2

1

10

20

30

40

0

2

1

3

0

5

10

1750 RPM1450 RPM

C MAG-PL50

HE

AD

[m

]

FLOW [US GPM]

PO

WE

R [kW

]

PO

WE

R [H

P]

NP

SH

r [m

]

NP

SH

r [ft]

HE

AD

[ft]

3FLOW [m /h]

0 20 40 60 80 100

9

8

7

5

6

4

3

2

1

30

25

20

15

10

5

54

123

0 0

5

10

15

0.4

0.3

0.5

0.6

0.7

0.5

0.3

0.4

0 2 4 6 8 10 12 14 16 18 20 22 24

HE

AD

[m

]

FLOW [US GPM]

PO

WE

R [kW

]

PO

WE

R [H

P]

NP

SH

r [m

]

NP

SH

r [ft]

HE

AD

[ft]

3FLOW [m /h]

0 20 40 60 80 100 120

40

30

20

10

4

3

2

1

0

10

0

5

0 5 10 15 20 25 30

1.0

0.9

0.8

0.7

0.6

0.5

1.3

0.8

0.9

1.0

1.1

1.2

1.4

0.7

9

13

11

7

5

3

1

1750 RPM1450 RPM

C MAG-PL65