Top Banner
BY DEREK H. AND YAZMEEN T. Lead Shielding and Muons 1
18
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: BY DEREK H. AND YAZMEEN T. Lead Shielding and Muons 1.

1

BY DEREK H. AND YAZMEEN T.

Lead Shielding and Muons

Page 2: BY DEREK H. AND YAZMEEN T. Lead Shielding and Muons 1.

2

TO DETERMINE HOW LEAD

THICKNESS AFFECTS THE

MUON COUNT RATE

Purpose

Page 3: BY DEREK H. AND YAZMEEN T. Lead Shielding and Muons 1.

3

The Experiment

The Question: How is muon flux affected by lead shielding?

From the captured data, we want to see if there is a

correlation between lead thickness and count rate.

Energies of muons will be looked at to help understand this

correlation; a loss of lower energy muons in lead will affect

count rate.

Page 4: BY DEREK H. AND YAZMEEN T. Lead Shielding and Muons 1.

4

Hypothesis

The majority of low energy muons will ionize and

interact with more atoms in the lead bricks than in

air, causing them to be slowed down or completely

stopped. We expect to see a substantial decline in

the count rate due to the lead bricks.

Page 5: BY DEREK H. AND YAZMEEN T. Lead Shielding and Muons 1.

5

Calibration/Plateauing

0.5 0.6 0.7 0.8 0.9 1 1.1 1.2 1.30

10

20

30

40

50

60

70

80

90

100

CPS A:2CPS BCPS CCPS D

• This is done to achieve the maximum signal to noise ratio

Page 6: BY DEREK H. AND YAZMEEN T. Lead Shielding and Muons 1.

6

Experiment Set-Up

Detector A

Detector BDetector CDetector D

Lead Bricks40cm

Page 7: BY DEREK H. AND YAZMEEN T. Lead Shielding and Muons 1.

7

Procedure

• Run a control to find the muon count-rate

• Calculate sky (solid) angle: Angle: 0.455 steradiansPercent of entire sky: 3.26%

• Shield with lead bricks in intervals of three

• Perform a 24 hour run for each layer of thickness

• Look how the flux varies with lead thickness

Page 8: BY DEREK H. AND YAZMEEN T. Lead Shielding and Muons 1.

8

Flux vs. Thickness of Lead

We tried an exponential fit to show the relationship between the flux and lead thickness

With an increase of thickness=decrease in flux

Flux= 618.75e-

0.009(thickness)

*expected a 1% decrease but

instead found 15% decrease

0 5 10 15 20 25 300

100

200

300

400

500

600

700

Counts/min

Exponential (Counts/min)

Lead Thickness (cm)

Flux (Counts/min)

Page 9: BY DEREK H. AND YAZMEEN T. Lead Shielding and Muons 1.

9

15% Decrease?

The concrete of the

building (4th floor

and roof concrete).

155/170 = less than

10% of muons are

blocked.

Page 10: BY DEREK H. AND YAZMEEN T. Lead Shielding and Muons 1.

10

Justification for the Exponential Fit

The range for the correlation coefficient (R2) is from -1 to 1.

How good of a correlation between two data sets.

R2 =0.7907

0 5 10 15 20 25 305

5.2

5.4

5.6

5.8

6

6.2

6.4

Natural Log of Flux

LNLinear (LN)Linear (LN)

Lead Thickness (cm)

Ln (Flux) (Counts/min)

Page 11: BY DEREK H. AND YAZMEEN T. Lead Shielding and Muons 1.

11Energy Loss Graph

This graph shows

the loss of energy

per distance

traveled, for

different

elements.

Page 12: BY DEREK H. AND YAZMEEN T. Lead Shielding and Muons 1.

12

Experiment: Analysis

Energy Loss:

Lead Density=11.3 g/cm3

-dE/dρx=(1.12MeVcm2/g)(11.3g/cm3)

-dE/dx=(12.7MeV/cm)

Find deltaE by multiplying the –dE/dx by the thickness of the

brick (5 cm).

DeltaEBrick =60.35MeV

Minimum Ionization energy

Page 13: BY DEREK H. AND YAZMEEN T. Lead Shielding and Muons 1.

13

Muon Counts

This shows the

cumulative counts

per second for

energies of muons

(at sea level).

Energy loss and

count rate

connection.

Less than 1% of muons have less than60MeV of kinetic energy.

Page 14: BY DEREK H. AND YAZMEEN T. Lead Shielding and Muons 1.

14

Recreating the Energy Distribution

50cm of concrete blocks less than 10% muons

~10% of muons in 20MeV -> 400MeV range-> Flux vs. Energy graph would be moved to lower energies by 400MeV

The larger population of higher energy muons are slowed down -> more lower energy muons after concrete.

Page 15: BY DEREK H. AND YAZMEEN T. Lead Shielding and Muons 1.

15

Recreating the Energy Distribution

Total Population = 100%

10% are lost -> Total = 90% of original population.After shift to lower energies, 20/90 = 22% of muons are less than 500MeV. 500MeV/8.3 = 60MeV, so 22%/8.3 = 2.66% > percent of muons with less than 60MeV of kinetic energy.

2.66% is much less than 15%

Page 16: BY DEREK H. AND YAZMEEN T. Lead Shielding and Muons 1.

16

5 cm Lead

50 cm Concrete

Energy Before Concrete

Theoretical

Page 17: BY DEREK H. AND YAZMEEN T. Lead Shielding and Muons 1.

17

Next Step…

We could increase data run time to get a more accurate percentage loss while doing further research into energy distribution.

One layer of lead repeat: 8% decrease (?)

Page 18: BY DEREK H. AND YAZMEEN T. Lead Shielding and Muons 1.

18

AND TO ALL THOSE WHO HELPED :STUART BRIBERVICKI JOHNSONJASON NIELSEN

TANMAYI SAIBRENDAN WELLS

THE SPEAKERSAND THE OTHER INTERNS

Thank You for Your Time