Sampoong Department Store
Five-story tall department store, complex.
40,000 people shopped in the department store every day.
New pink edifice of commercialization.
Background Information
Owner is Mr.Lee Joon. Constructed in 1987. Considered to be one of the
“swankiest” stores in town. Had everything under one roof, from
a gourmet grocery to high-end clothing and cosmetic boutiques.
Disaster Strikes!
6:00 pm on June 29th, 1995. In less than 20 seconds, the 5-story
department store collapses into its four basements.
Estimated 1,500 unsuspecting shoppers and employees trapped inside.
Statistics
Killed more than 500 people. Injured over 900 people. Resulted in about ₩270 billion
(approximately US$216 million) worth of property damage.
So why did it collapse??
No signs of a natural disaster.
•Was not a terrorist act.
•No wrecking ball was in sight.
Looking Deeper
Architect’s drawings did not match the engineers calculations.
Still not within building standards the structure should have been safe because of the margins of error calculated into design standards.
Management Decisions
Originally designed as an office building with four floors.
Mr. Joon carried out modifications over objections of the original contractors, whom he fired and replaced.
Construction Flaws
Foundation on a former trash dump. Addition of the concrete slab for the
5th floor exceeded the design loads by a factor of 4.
Relocation of AC unit on roof damaged the roof structure.
Concrete was mixed with salt-water, speeding the deterioration of the steel used to strengthen the building.
Construction Flaws Part 2
Rebars were centimeters thinner than regulations would allow.
Size of columns reduced from 80 cm to 60 cm (under regulation size).
16 rebars per column was reduced to 8. Support columns were cut away to
accommodate escalators. OVERALL-the strength was reduced by
half.
Weren’t there any signs?
Warnings
Building showed cracking due to the overload.
Cracks appeared in the ceiling of the fifth floor.
A worker noted a gas leak but request to close store was denied.
At the day of the collapse, the ceiling on the fifth floor started crumbling.
Response
The only response to this was an order from Mr. Joon to move the expensive merchandise from the fifth to the ground floor.
No further action was taken, nothing that would hinder the daily income.
Conclusion
It is considered the worst disaster in South Korea's (admittedly short) history as well as the worst structural collapse of a building in modern history.
Blamed for faulty design and shortcuts during construction.