GEN-ABSTCONSTRUCTION OF TOILET BLOCK BUILDING AT
DARGAH-E-HAZRATH KHWAJA BANDA NAWAZ, GULBARGA-KARNATAKAGENERAL
ABSTRACT4401116Sl. No.Item of WorkAmount(Rs. In Lakhs)1GROUND
FLOOR92.0002FIRST FLOOR70.100GRAND TOTAL Rs.162.1001.62
FinalCONSTRUCTION OF TOILET BLOCK BUILDING AT DARGAH-E-HAZRATH
KHWAJA BANDA NAWAZ, GULBARGA-KARNATAKADETAILED AND ABSTRACT
ESTIMATE FOR FIRST FLOORSl. No.Description of
ItemsMeasurementQty.UnitRateAmountNo.LBD1KSRB 2-2.1: Earthwork
excavation for foundation of buildings, culverts, water supply,
sanitary lines and electrical conduits either in pits or in
trenches 1.5 m and above in width in ordinary soil not exceeding
1.5 m. in depth including dressing the bottom and sides of pits and
trenches, stacking the excavated soil clear from edges of
excavation with lead upto 50 m. after breaking of colds complete as
per specifications. Specification. No. KBS 2.1(a)/ 2.3.5 (PWP &
ITWD DSR, Glb. 2013-14 P.No. 5 I.No.
2.3)Column-F1121.801.802.0077.76Column-F2121.801.802.0077.76Column-F3132.102.102.00114.66Column-F492.102.102.0079.38Column-F522.102.102.0017.64Column-F632.102.102.0026.46Total393.66Cum13954718.742KSRB
4-1.3: Providing and laying in position plain cement concrete of
nominal mix M7.5 with OPC cement @ 180 Kg with 40 mm and down size
graded granite metal coarse aggregates @ 0.85 cum and fine
aggregates @ 0.57 cum machine mixed, concrete laid in layers not
exceeding 15 cms thick well compacted in foundation and plinth
including cost of all materials, labour, HOM of machinery, curing,
complete as per specification (PWP & IWTD DSR, Glb. 2013-14
P.No. 12 I.No.
4.3)Column-F1121.801.800.155.832Column-F2121.801.800.155.832Column-F3132.102.100.158.5995Column-F492.102.100.155.9535Column-F522.102.100.151.323Column-F632.102.100.151.9845Total29.5245Cum3877114466.48653KSRB
4.2.9: Providing and laying in position reinforced cement concrete
of mix M15 with OPC cement @ 240 Kgs with 20 mm and down size
graded graite metal coarse aggregates @ 0.878 cum and fine
aggregates at 0.459 cum, machine mixed concrete laid in layers not
exceeding 15 cms thick vibrated for RCC beams, columns of all sizes
in foundation plinth and super structure ground floor level for
roof slabs, staircase, lintels, columns including cost of all
materials, labour, HOM of machinery, curing complete as per
specification (PWP & IWTD DSR Glb. 2012.13 P.No. 15 I.No.
4.18)First
FootingColumn-F1121.501.500.236.21Column-F2121.501.500.236.21Column-F3131.801.800.239.69Column-F491.801.800.236.71Column-F521.801.800.301.94Column-F631.801.800.302.92Secand
FootingColumn-F1121.201.200.305.18Column-F2121.201.200.305.18Column-F3131.501.500.3710.82Column-F491.501.500.377.49Column-F521.501.500.301.35Column-F631.501.500.302.03Coloumn
Upto Roof LevelColoumn - C1120.450.2310.0512.48Coloumn -
C2120.450.2310.0512.48Coloumn - C3130.600.2310.0518.03Coloumn -
C490.600.2310.0512.48Coloumn - C520.600.2310.052.77Coloumn -
C630.600.2310.054.16Plinth
BeamPB11173.040.230.3011.94PB2110.830.230.300.75PB3150.080.230.384.38PB4122.450.230.452.32PB5125.320.230.382.21Total149.74Cum4447665908.882012
DET&ABS (37)CONSTRUCTION OF TOILET BLOCK BUILDING AT
DARGAH-E-HAZRATH KHWAJA BANDA NAWAZ,
GULBARGA-KARNATAKA52558.435911DETAILED AND ABSTRACT ESTIMATE FOR
FIRST FLOORSl. No.Description of
ItemsMeasurementQty.UnitRateAmountNo.LBD1KSRB 4.2.9: Providing and
laying in position reinforced cement concrete of mix M15 with OPC
cement @ 240 Kgs with 20 mm and down size graded graite metal
coarse aggregates @ 0.878 cum and fine aggregates at 0.459 cum,
machine mixed concrete laid in layers not exceeding 15 cms thick
vibrated for RCC beams, columns of all sizes in foundation plinth
and super structure ground floor level for roof slabs, staircase,
lintels, columns including cost of all materials, labour, HOM of
machinery, curing complete as per specification (PWP & IWTD DSR
Glb. 2012.13 P.No. 15 I.No. 4.18)Column
(Ht=11)C1120.751.5011.00148.50C2120.751.5011.00148.50C3130.752.0011.00214.50C490.752.0011.00148.50C520.752.0011.0033.00C630.752.0011.0049.50Roof
beam1878.500.751.50988.31Lintel1878.500.750.50329.44Roof
slab1106.1374.750.544283.74Dedt-18.758.500.54-40.16-117.5037.000.54-349.65-175.635.000.54-204.20-142.0010.750.54-243.81-151.006.500.54-179.01-120.7516.000.54-179.28Staircase418.004.000.42120.9620x4.001.000.5040.005308.83CftSay150.48Cum4447.006691722KSRB
6.2.2: Providing and constructing burnt brick masonry with approved
quality of non-modular bricks of standard size of class designation
50 (table moulded) with cement mortar 1:6 for basement and
superstructure including cost of materials, labour charges,
scaffolding, curing complete as per specifications. Specification
No. KBS 6.2 (PWP & IWTD DSR, Glb. 2013-14 P.No. 30 I.No.
6.6)External Walls13470.7511.002862.75Gents
Toilet1240.420.7511.001983.47Ladies
Toilet1228.250.7511.001883.06Partition WallGents
Toilet1020.50.3311.00744.15WC304.000.3311.00435.60Bath141.50.3311.00150.6510411.000.33145.20Ladies
Toilet326.2511.000.33285.8612411.000.33174.24119.5011.000.3370.7944.0011.000.3358.088411.000.33116.16Duct
Area174.1711.000.33269.2416411.000.33232.32Store15.8811.000.3321.33Deduct
Door
D-912.507.000.33-525.53D1-94.007.000.33-83.16-173.001.500.75-57.38Lintel-1878.500.750.50-329.44Deductions
V-1505.340.752.00-379.01Steps45.002.501.5075.001404.10CftSay39.80Cum5194.002067153KSRB
15.3.8: Providing 18mm thick cement plaster in single coat with
cement mortar 1:4, to brick masonry including rounding off corners
wherever required smooth rendering,: Providing and removing
scaffolding, including cost of materials, labour, curing complete
as per specifications. (PWP & IWTD DSR, Glb. 2013-14 P.No. 123
I.No.
15.16)Room-1159.3011.00652.30Room-2165.0011.00715.00Room-3165.0011.00715.00Gents
Toilet W/c
Area363.0011.002079.002920.5011.006539.50604.0011.002640.00Staircase
area150.1311.00551.38Bath
area174.1711.00815.87141.2511.00453.75194.0011.00836.00115.0011.00165.00Ladies
Toilet W/c
-Bath1276.3411.003039.74W/C175.0011.00825.001267.0011.002937.001140.2511.001542.75Store131.4111.00345.51Wash
Basin Area172.2511.00794.75Ladies
Staircase161.5011.00676.50Passage1191.5011.002106.50Deduct
D-912.507.00-1592.50D1-94.007.00-252.0026586.05Say2470.82Sqm164.004052154KSRB
15.3.13: Providing 12mm thick cement plaster in single coat with
cement mortar 1:3, to ceiling including rounding off corners
wherever required smooth rendering, Providing and removing
scaffolding, including cost of materials, labour, curing complete
as per specifications. (PWP & IWTD DSR, Glb. 2013-14 P.No. 123
I.No. 15.21)Gents
Toilet334.005.00660.00Passage137.715.00188.55320.504.00246.00Room-3110.0014.00140.00Room-2110.0014.00140.00Room-119.1314.00127.75Bath14.005.0020.00W/c18.715.7550.08Urinals127.675.75159.10Wash
Basin Area131.7110.00317.10Ladies
Toilet194.005.00380.00Passage225.754.00206.00Toilet44.005.0080.00Passage18.504.0034.00Bath174.005.00340.00Passage174.176.42476.17HWC15.889.8357.75Wash
Basin
Area128.389.75276.66Passage137.7510.00377.50127.7510.00277.50110.506.5068.25Ladies
Staircase121.009.75204.75Staircase plaster
Slab018.004.000.00018.001.000.004827.16Say448.62Sqm145.00650505KSRB
15.3.11: Providing 20mm thick cement plaster in single coat with
cement mortar 1:4, to stone masonry including rounding off corners
wherever required smooth rendering, Providing and removing
scaffolding, including cost of materials, labour, curing complete
as per specifications. (PWP & IWTD DSR, Glb. 2013-14 P.No. 123
I.No. 15.19)1347.0011.003817.00Duct
area274.1711.001631.7425.0011.00110.00Deductions
V-1505.342.00-1010.684548.06Say422.68Sqm174.00735476KSRB 14.10-1:
Flooring with 25mm to 40mm thick polished Tandur blue stone slabs
using cement mortar 1:6, 25mm thick over existing cement concrete
bed or top of roof laid to line and level and jointed with cement
slurry mixed with pigment to match the shade of the slab, including
finishing cost of materials, labour, curing complete as per
specifications. (PWP & IWTD DSR, Glb. 2013-14 P.No. 112 I.No.
14.15)Passage131.7110.00317.10520.504.00410.00142.255.00211.25Passage18.504.0034.00Passage174.176.42476.17Wash
Basin
Area128.389.75276.66Passage137.7510.00377.50127.7510.00277.50110.506.5068.25Ladies
Staircase121.009.75204.75Staircase plaster
Slab018.004.000.00018.001.000.002653.18Say246.58Sqm941.002320307KSRB
14.14-5: Providing Ceramic tiles of approved make, shade and size
for flooring, treads of steps and landings laid on a bed of 12mm
thick, cement mortar 1:3 mix, flush pointing with white cement
using colour pigment, including cost of materials, labour, curing,
complete as per specifications ceramic tiles of size 30x30 cms.
(PWP & IWTD DSR, Glb. 2013-14 P.No. 115 I.No.
14.36.2)Toilet/Bath
flooring914.005.001820.00Dadoing9118.007.0011466.00128.927.00202.44Washbasin
area131.717.00221.97131.327.00219.24Deduct door
D1-912.507.00-1592.5012337.15Say1146.58Sqm941.0010789278KSRB 4.9.2:
Providing Fe500 TMT bars reinforcement for RCC work including
straightening, cutting, bending, hooking, placing in position,
lapping and/ or welding, wherever required, tying with binding wire
and anchoring to the adjoining members wherever necessary complete
as per design (laps, hooks and wastage shall not be measured and
paid) cost of materials, labour, HOM of machinery complete as per
specification. Specification No. KBS 4.6.3. (PWP & IWTD DSR,
Glb. 2013-14 P.No. 19 I.No. 4.46.2)Column, beam & lintel58.38@
110 Kg/Cum6421.80Roof slab87.50@ 80 Kg/Cum7000.00Staircase2.28@ 80
Kg/Cum182.4013604.20KgsSay136.04Qtl6846.009313449KSRB 9.4-3:
Providing matti/ nandi wood frames of doors, windows, clerestory
windows, ventilators and other frames, wrought, framed or assembled
including making plaster groves (excluding cost of cement concrete
and side clamps), but including cost of materials, labour, HOM of
machineries complete as per specifications. Specification No. KBS
9.33 (PWP & IWTD DSR, Glb. 2013-14 P.No. 56 I.No.
9.12)D13.5+2x70.330.422.43D1913.0+2x70.330.42214.41216.84CftSay6.15Cum65470.0040239510KSRB
9-7.3: Providing and fixing in position fully panelled nandi wood
shutters for doors, styles and rails of 30mm. thick with bottom and
lock rails 180mm wide top rail and styles 100mm wide as per drawing
and panels of 25mm thick including cost of materials, labour, HOM
of machineries complete as per specifications. (excluding cost of
fixtures) Specification No. KBS 9.34 (PWP & IWTD DSR, Glb.
2013-14 P.No. 57 I.No.
9.22)D13.007.0021.00D1912.507.001592.501613.50SftSay149.95Sqm2781.0041702111KSRB
7.7: Providing and fixing in position in cement concrete 1:3:6
Steel glazed winfows and ventilators side hung/ top hung fully
openable as per approved drawings using Z angles of 25x33x3
weighing 1.419 Kg/m both for outer and inner frames and cental
mullion section of size 25x46x3 mm . Weighing 2.28 Kg/m duly
providing T section 19x19x3 mm weighing 0.839 kg/m for glazing of
windows not more than 34 cms c to c including providing anf fixing
4 mm . thick reeded glass with Teak wood beading of required size,
all sections should confirm to IS 7452:1990, 4 Nos of holdfasts of
approved size, section should be cut to length welded and
electrically grinded suubdividing frames of unit shall be tenonned
and revetted in to the frames electrically. All steel surface shall
be roughly cleaned free of rust and painted with one coat of
anticorrosive paint and finishing with two coats of ready mix paint
of approved colour and make including cost of materials, fixtures,
labour and HOM of machinery complete as per specifications. (PWP
& IWTD DSR, Glb. 2013-14 P.No. 37 I.No.
7.7)Ventilators1505.342.001010.681010.68SftSay93.93Sqm3413.0032058112KSRB
7.1: Providing and fixing in position collapsible steel shutters
with single or double leaf with vertical channel 20mmx10mmx2mm
braced with flat iron diagonals 20mmx5mm size, with top and bottom
rails of T iron sections of 40x40x6mm with 38mm dia steel pulleys
complete with bolt and nuts, locking arrangements, stoppers,
handles on both sides with 7.5cms openings at 10 cms c to c
applying a priming coat of red lead paint, cost of materials,
labour, HOM of machinery complete as per specifications. size of
gate 2.4mx1.4m. Specification No. KBS 7.7 / 7.12 (PWP & IWTD
DSR, Glb. 2013-14 P.No. 36 I.No.
7.1)Corridor110.007.0070.0070.00SftSay6.51Sqm4051.00263541315.17.1:
Applying priming coat over new wood surface and / or wood based
surface with white lead paint priming including preparing the
surface after throughly cleaning oil, grease, dirt and foreign
matter, sand papering and knotting ready mix paint including cost
of materials, labour, complete as per specifications. (PWP &
IWTD DSR, Glb. 2013-14 P.No. 127 I.No.
15.55)D13.007.002.2547.25D1912.507.002.253583.133630.38SftSay337.40Sqm27.50927814KSRB
15-18.1: Applying red lead ready mix priming coat over new steel or
other metal surface including preparing the surface after
thoroughly cleaning oil, grease, dirt and other foreign matter, and
scoured with wire brushes, fine steel wool, sand papers including
cost of materials, labour, complete as per specifications. (PWP
& IWTD DSR, Glb. 2013-14 P.No. 130 I.No.
15.73)Ventilators1505.342.001010.68Collapsible
gate110.007.0070.001080.68SftSay100.43Sqm23.40235015KSRB 15.17.6:
Providing and applying painting two coats (excluding priming coat)
on new wood surface and/ or wood based surface with enamel paint to
give an even shade, cleaning the surface of all dirt, dust and
foreign matter, sand papering including cost of materials, labour,
complete as per specifications. (PWP & IWTD DSR, Glb. 2013-14
P.No. 128 I.No.
15.60.1)D13.007.002.2547.25D1912.507.002.253583.133630.38SftSay337.40Sqm73.702486616KSRB
15-18.2: Providing and applying enamel metal paint two coats
(excluding priming coat) over new steel or other metal surface
brushing to give an even shade after cleaning oil, grease, dirt and
other foreign matter, including cost of materials, labour, complete
as per specifications. (PWP & IWTD DSR, Glb. 2013-14 P.No. 130
I.No. 15.74)Ventilators1505.342.001010.68Collapsible
gate110.007.0070.001080.68SftSay100.43Sqm71.84721517KSRB 15.14.1:
Providing and applying two coats with oil bound washable distemper
of approved brand and shade on wall surface including priming coat
with distemper primer after thoroughly brooming the surface free
from mortar drops and other foreign matter, including preparing the
surface, even and sand paper smooth, cost of materials, labour,
complete as per specifications. (PWP & IWTD DSR, Glb. 2013-14
P.No. 126 I.No. 15.49.1)Inside Plaster Qty26586.05Ceiling Plaster
Qty4827.1631413.21SftSay2919.44Sqm55.5516217518KSRB 15.16.1:
Providing and finishing external walls in two coats with water
proof cement paint of approved brand and shade to give an even
shade after throughly brooming the surface to remove all dirt and
loose powdered material, free from mortar drops and other foreign
matter cost of materials, labour, complete as per specifications.
(PWP & IWTD DSR, Glb. 2013-14 P.No. 127 I.No. 15.53.1)Outside
plaster4548.064548.06SftSay422.68Sqm48.922067819KSRB 11-2:
Providing and fixing White vitreous china clay , water closet
orissa patten of size 580x440 mm with integral type footrests ,
100mm S or P trap, 10 litre low level , PVC flushing cistern (all
are approved make) with fittings, CI/MS Brackets , 32 mm diameter
flush pipe fittings and clamps , overflow arrangements with special
and 25mm mosquito proof coupling of approved design , painting of
fittings and brackets , cutting and making good the wall and floor
whereever required ,including cost of materials , labour complete
as per specifications. (PWP & IWTD DSR, Glb. 2013-14 P.No.79
I.No. 12.2)Pan74.00Pan4185.0030969020KSRB 11-11.1: Providing and
fixing White vitreous china clay , Flat back wash basin size
630x450mm wtith a pair of 15mm CP Brass Pillar Tap with CI/MS
Brackets ,32 mm CP Brass waste of standard pattern , painting of
fittings and brackets , cutting and making good the wall and floor
whereever required ,including cost of materials , labour complete
as per specifications. (PWP & IWTD DSR, Glb. 2013-14 P.No. 82
I.No. 12.23)20.00Unit3838.007676021Add Lumpsum for Door
Fixtures100000TOTAL5541363Add 7.5% for internal
electrification415602Add 7.5% for water supply and sanitation
work415602TOTAL6372567Add 10% lift charges637257TOTAL7009824Add LS
for other miscellaneous item176GRAND TOTAL7010000
&C&P
AbstractTourism Development Works in Gulbarga City
Construction of Toilet and Kitchen Block at Khwaja Banda Nawaz
(Rh.) at Gulbarga.ABSTRACTSl. No.Sub - EstimateDescriptionAmount in
Rs.Amount in Crores1Sub - Estimate - 1Construction of Toilet Block
Building and Dining Hall at Dargah Hazarath Khwaja Banda Nawaz
(Rh), Gulbarga.14038273.271.402Sub - Estimate - 2Water Supply and
Sanitation for Toilet and Kitchen Block at Dargah Hazarath Khwaja
Banda Nawaz (RH) at Gulbarga.1789564.980.183Sub - Estimate -
3Electrical Estimate of Proposed Toilet and Kitchen Block at Dargah
at Hazrat Khwaja Banda Nawaz (Rh) at Gulbarga.439177.000.04Grand
Total16267015.241.631.627
Toilet Block updatedSUB ESTIMATE 1 :-Construction of Toilet
Block Building and Dining Hall at Dargah Hazarath Khwaja Banda
Nawaz (Rh), Gulbarga.Sl. NoParticulars of workNoL (m)B (m)D
(m)QtyUnitRate (Rs)Amount (Rs)1Surface EXCIVATIONKSRB 2-1.2 :
Earthwork in surface excavation in Ordinary soil for levelling and
lowering the ground manually (other than foundation of buildings,
culverts, road drainns and trenches of pipe line and cables) and
removing the excavated ftuff to a distance not exceeding 50m and
lift up to 1.5m, excavated surface levelled and neatly dressed,
disposed earth to be neatly dressed as per specificaton. Page No-6
Item No 2.2(PW,P & IWTD,Gulbarga circle Gulbarga Circle 2013-14
P-5 i-2.1)143.00240.15154.80Cum116.0017956.802EXCAVATIONKSRB 2-2.2
Earthwork excavation for foundation of buildings, watersupply ,
sanitary lines & electrical conduits either in pits or in
trenches 1.5 m & above in width, in hard soil not exceeding 1.5
m in depth including dressing the bottom & sides of pits &
trenches, starting the excavated soil clear from edges of
excavation with lead upto 50 m after breaking the clods with all
lead and lift, including cost and conveyance of all materials,
labour, all other incidental charges etc., complete as per
specification and as directed by the Engineer-in-charge of
work.(PW,P & IWTD,Gulbarga circle Gulbarga Circle 2013-14 P-5
i-2.4)For PitsFooting F141.501.502.0018.00Footing
F291.501.502.0040.50Footing F3181.501.202.0064.80Footing
F461.501.502.0027.00Footing F5181.801.802.00116.64Footing
F691.801.802.0058.32325.26Cum209.0067979.343P.C.C 1:3:6KSRB 4-1.3:
Providing and laying in position plain cement concrete of nominal
mix M7.5 with OPC cement @ 180 Kg with 40 mm and down size graded
granite metal coarse aggregates @ 0.85 cum and fine aggregates @
0.57 cum machine mixed, concrete laid in layers not exceeding 15
cms thick well compacted in foundation and plinth including cost of
all materials, labour, HOM of machinery, curing, complete as per
specification (PWP & IWTD DSR, Glb. 2013-14 P.No. 12 I.No.
4.3)For PitsFooting F141.501.500.151.35Footing
F291.501.500.153.04Footing F3181.501.200.154.86Footing
F461.501.500.152.03Footing F5181.801.800.158.75Footing
F691.801.800.154.3724.39Cum3877.0094577.484KSRB 4.2.9: Providing
and laying in position reinforced cement concrete of mix M20 with
OPC cement @ 320 Kgs with 20 mm and down size graded graite metal
coarse aggregates @ 0.69 cum and fine aggregates at 0.46 cum,
machine mixed concrete laid in layers not exceeding 15 cms thick
vibrated for RCC beams, columns of all sizes in foundation plinth
and super structure ground floor level for roof slabs, staircase,
lintels, columns including cost of all materials, labour, HOM of
machinery, curing complete as per specification (PWP & IWTD DSR
Glb. 2013.14 P.No. 15 I.No. 4.17)FootingsFooting
F141.201.200.251.44Footing F291.201.200.253.24Footing
F3181.200.900.254.86Footing F461.201.200.302.59Footing
F5181.501.500.3012.15Footing F691.501.500.306.08Conical
ShapeFooting F140.720.720.200.41Footing F290.720.720.351.61Footing
F3180.720.570.352.55Footing F460.720.720.300.92Footing
F5180.870.870.304.04Footing F690.870.870.302.02Total Quantity of
Footings41.90Coloumns Upto First Floor
SlabC140.230.454.902.03C290.230.454.754.42C3180.230.454.758.85C460.230.604.803.97C5180.230.604.8011.92C690.230.604.805.96Total
Quantity of Coloumn37.16Plinth BeamPB1 Front Full
Length137.930.230.302.62PB1116.610.230.301.15PB1114.580.230.301.01PB115.820.230.300.40PB114.000.230.300.28PB1222.190.230.303.06PB1122.410.230.301.55PB118.140.230.300.56PB114.870.230.300.34PB112.590.230.300.18PB114.200.230.300.29PB112.230.230.300.15PB118.000.230.300.55PB113.000.230.300.21PB113.300.230.300.23PB1117.520.230.301.21PB113.780.230.300.26PB116.940.230.300.48PB116.630.230.300.46PB268.350.230.303.46PB214.300.230.300.30PB213.000.230.300.21PB222.440.230.300.34PB313.000.230.380.26PB315.120.230.380.45PB315.730.230.380.50PB315.380.230.380.47PB314.060.230.380.35PB314.280.230.380.37PB315.370.230.380.47PB445.880.230.452.43Total
Quantity of Plinth Beam24.58Roof
BeamB1114.520.230.451.50B1322.410.230.456.96B119.410.230.450.97B1117.810.230.451.84B1113.150.230.451.36B118.700.230.450.90B1110.460.230.451.08B112.610.230.450.27B113.460.230.450.36B116.930.230.450.72B112.830.230.450.29B2114.750.230.451.53B2115.040.230.451.56B214.130.230.450.43B212.820.230.450.29B214.070.230.450.42B214.490.230.450.46B213.230.230.450.33B215.470.230.450.57B328.120.230.451.68B3104.760.230.454.93B315.840.230.450.60B355.250.230.452.72B315.260.230.450.54B446.930.230.603.83B426.600.230.601.82Total
Quantity of Roof Beam37.97Roof SlabFor Gents
Toilet122.899.780.1533.58For Ladies Toilet122.894.270.1514.66For
Ladies Toilet119.742.840.158.41For Ladies
Toilet17.124.800.155.13For Ladies Toilet12.742.820.151.16For Ladies
Toilet16.583.230.153.19Passage120.113.000.159.05Passage12.233.600.151.20Cooking
Hall114.604.300.159.42Cooking Hall14.306.500.154.19Store
Room14.122.820.151.74Stair Case15.332.920.152.33Total Quantity of
Roof Slab94.06Grand total of Ground
Floor235.68Cum5071.001195115.56For First Floor Additional rate of
Rs. 50.00/CumColoumn From Ground floor Roof Slab to First Floor
Roof
SlabC140.230.455.162.14C290.230.455.164.81C3180.230.455.169.61C460.230.65.164.27C5180.230.65.1612.82C690.230.65.166.41Total
Quantity of Coloumn40.05Roof
BeamB1114.520.230.451.50B1322.410.230.456.96B119.410.230.450.97B1117.810.230.451.84B1113.150.230.451.36B118.70.230.450.90B1110.460.230.451.08B112.610.230.450.27B113.460.230.450.36B116.930.230.450.72B112.830.230.450.29B2114.750.230.451.53B2115.040.230.451.56B214.130.230.450.43B212.820.230.450.29B214.070.230.450.42B214.490.230.450.46B213.230.230.450.33B215.470.230.450.57B328.120.230.451.68B3104.760.230.454.93B315.840.230.450.60B355.250.230.452.72B315.260.230.450.54B446.930.230.63.83B426.60.230.61.82Total
Quantity of Roof Beam37.97Roof SlabFor Gents
Toilet122.899.780.1533.58For Ladies Toilet122.894.270.1514.66For
Ladies Toilet119.742.840.158.41For Ladies Toilet17.124.80.155.13For
Ladies Toilet12.742.820.151.16For Ladies
Toilet16.583.230.153.19Passage120.1130.159.05Passage12.233.60.151.20Cooking
Hall114.64.30.159.42Cooking Hall14.36.50.154.19Store
Room14.122.820.151.74Stair Case15.332.920.152.33Total Quantity of
Roof Slab94.06Total Quantity of First
Floor172.09Cum5121.00881264.475FillingaKSRB 2.3 : Filling available
excavated earth (excluding rock) in sides of foundations upto
plinth in layers not exceeding 20 cms. in depth, compacting each
deposited layer by ramming after watering with lead upto 50m. and
lift upto 1.5m. including cost of all labour complete as per
specifications.(PW,P & IWTD,Gulbarga circle Gulbarga. 2013-14
It. No. 2.10, P. No. 6)For Gents Toilet122.899.780.45100.74For
Ladies Toilet122.894.270.4543.98For Ladies
Toilet119.742.840.4525.23For Ladies Toilet17.124.80.4515.38For
Ladies Toilet12.742.820.453.48For Ladies
Toilet16.583.230.459.56Passage120.1130.4527.15Passage12.233.60.453.61Cooking
Hall114.64.30.4528.25Cooking Hall14.36.50.4512.58Store
Room14.122.820.455.23Total Qty275.19Cum93.925840.1569216BBM in CM
1:6KSRB 6-2.3 Providing and constructing burnt brick masonary with
approved quality of non modular bricks of standard size of class
designation 50(table moulded) with cement mortar 1:6 for basement
and super structure including cost of materials.labours charges,
scaffolding,curing complete as per specification No KBS 6.3(PW,P
& IWTD,Gulbarga circle Gulbarga. 2013-14 It. No. 6.6 P.
No30)Outer Wall Full Length1140.640.233.20103.51Inner
Wall222.380.233.2032.94Inner Wall19.460.233.206.96Inner
Wall44.300.233.2012.66Inner Wall11.520.233.201.12Deduction of
OpeningGate13.000.233.20-2.21Door D141.200.232.10-2.32Door
D221.500.232.10-1.45Ventilatar163.000.230.60-6.62For Ground
FloorNet Qty144.60Cum5194.00751028.92Outer Wall Full
Length1140.640.233.2103.51Inner Wall222.380.233.232.94Inner
Wall19.460.233.26.96Inner Wall44.30.233.212.66Inner
Wall11.520.233.21.12Deduction of OpeningDoor
D141.200.232.10-2.32Door
D221.500.232.10-1.45Ventilatar163.000.230.60-6.62For First FloorNet
Qty146.80Cum5219.00766167.36For Parapet Wall (Full
length)1140.640.230.7524.26Cum5219.00126615.037TMT steelKSRB 4.9.2
: providing TMT steel reinforcement for RCC work including
straighten, cutting, bending, placing in position lapping & /
or welding wherever required tying with+B48 binding wire and
anchoring to the adjoining members wherever necessary completed as
per design (lapps, hooks & eastage shall not be measured &
paid) cost of materials, labour, HOM of machinery complete as per
specification & lift charge for steel of all diameters for
additional floors over ground floor per q floor height of 3.5m or
part there of cost of labour, complete as per specifications.No-KBS
4.6.3 (Fe 500)(PWDSR 2013-14 P-16 It no-4.46.2)62.13For Ground
Floor 100Kg/ Cum1235.6823567.65Kgs2356765.047579.06For First Floor
100Kg/
Cum1172.0917208.84Kgs1720883.5587.5Total40776.49Kgs228.6922869400776.49/100407.76Qtl6846.002791558.23228.698Centering
Charges40547.80AKSRB 4-6.1 : Providing and removing centering,
shuttering, strutting, propping etc., and removal of form work for
foundations, footings, bases of columns for mass concrete including
cost of all materials, abour complete as per specifications.
Specification No. KBSspecification No. KBS 4.6.2(PWD DSR 2013-14
It.No.4.28, P.No.16For FootingFooting F141.201.200.251.44Footing
F291.201.200.253.24Footing F3181.200.900.254.86Footing
F461.201.200.302.59Footing F5181.501.500.3012.15Footing
F691.501.500.306.0830.36Sqm197.005980.33BKSRB 4-6.5 : Providing and
removing centering, shuttering, strutting, propping etc., for
columns, pillars, piers, abutments, post and struts, square /
rectangular / polygon in plan including cost of all materials,
labour complete as per specifications.(PWD DSR 2013-14 It No.4-32 P
No.17)For Coloumn upto Ground
FloorC140.230.454.902.03C290.230.454.754.42C3180.230.454.758.85C460.230.604.803.97C5180.230.604.8011.92C690.230.604.805.96Total
Qty For Coloumn upto Ground Floor37.16Sqm303.0011259.99For Coloumn
First Floor ( Additional rate Rs. 20 Shall be added for every
additional meter or part there of for the above
limits.C140.230.455.162.14C290.230.455.164.81C3180.230.455.169.61C460.230.65.164.27C5180.230.65.1612.82C690.230.65.166.41Total
Qty For Coloumn First Floor40.05Sqm403.0016141.96CKSRB 4-6.7 :
Providing and removing centering, shuttering, strutting, propping
etc., and removal of form work for sides and soffits of beams, beam
haunchings, cantilever girders, bressumers and lintels not
exceeding 1m in depth including cost of all materials, labour
complete as per specifications. Specification No. KBS 4.6.2PWD
SR.2013-14 It No.4-34 P No 17Plinth BeamPB1 & PB2
(0.30+0.23+0.30)=0.831279.210.83231.74PB3
(0.38+0.23+0.38)=0.99132.940.9932.61PB4
(0.45+0.23+0.45)=1.13123.521.1326.58Total Qty For Plinth
beam290.93Sqm219.0063714.22Roof BeamRB1, RB2,
RB31304.181.13343.72RB4140.921.4358.52Total Qty For Roof
beam402.24Sqm219.0088090.34RB1, RB2,
RB31304.181.13343.72RB4140.921.4358.52For First Floor Roof
Beam402.24Sqm319.00128314.24KSRB 4-6.2 : Providing and removing
centering, shuttering, strutting, propping etc., and removal of
form work for flat surface such as suspended floors, roofs.
landings, balconies and likes, thickness upto 200mm including cost
of all materials, labour com Gulbarga circle Gulbarga. 2013-14 It
No.4.29 , P. No.14For ground Floor SlabFor Gents
Toilet122.899.78223.86For Ladies Toilet122.894.2797.74For Ladies
Toilet119.742.8456.06For Ladies Toilet17.124.8034.18For Ladies
Toilet12.742.827.73For Ladies
Toilet16.583.2321.25Passage120.113.0060.33Passage12.233.608.03Cooking
Hall114.604.3062.78Cooking Hall14.306.5027.95Store
Room14.122.8211.62Stair Case15.332.9215.56Total Quantity of Roof
Slab627.09Sqm257.00161162.72For Gents Toilet122.899.78223.86For
Ladies Toilet122.894.2797.74For Ladies Toilet119.742.8456.06For
Ladies Toilet17.124.834.18For Ladies Toilet12.742.827.73For Ladies
Toilet16.583.2321.25Passage120.11360.33Passage12.233.68.03Cooking
Hall114.64.362.78Cooking Hall14.36.527.95Store
Room14.122.8211.62Stair Case15.332.9215.56Total Quantity of Roof
Slab627.09Sqm800.00501673.84Total Quantity of First Floor9Partition
WallKSRB 6-7.4 :Construction of Partition wall 11.2 cms thick with
non modular table moulded burnt bricks of class designation 50 with
cement mortar 1:4 including cost of materials, labour charges,
scaffolding, curing with all lead and lift, including cost and
conveyance of all materials, labour, all other incidental charges
etc., complete as per specification and as directed by the
Engineer-in-charge of work.(PWD DSR 2013-14 P-33 L-6.26)For Toilet
Block ( Gents) Main26.202.1326.41For Toilet Block ( Gents)
(WC)242.002.13102.24For Toilet Block ( Gents) (
Bath)102.002.1342.60For HWC14.952.1310.54Urinals61.302.1316.61For
Toilet Block ( Ladies) Main113.422.1328.58For Ladies Toilet (Bath
and WC)162.002.1368.16For Ladies Toilet (Bath )11.332.132.83For
Ladies Toilet (Bath and WC)181.903.13107.05For Ladies Toilet (Bath
and WC)61.904.1347.08For cooking Hall114.581.2017.50For cooking
Hall17.771.209.32For cooking Hall23.351.208.04For cooking
Hall53.281.2019.68For Ground Floor506.66Sqm697.00353138.54For First
FloorFor Toilet Block ( Gents) Main26.22.1326.41For Toilet Block (
Gents) (WC)2422.13102.24For Toilet Block ( Gents) (
Bath)1022.1342.60For HWC14.952.1310.54Urinals61.32.1316.61For
Toilet Block ( Ladies) Main113.422.1328.58For Ladies Toilet (Bath
and WC)1622.1368.16For Ladies Toilet (Bath )11.332.132.83For Ladies
Toilet (Bath and WC)181.93.13107.05For Ladies Toilet (Bath and
WC)61.94.1347.08Total Qty452.12Sqm697.00315124.1610Grill DoorKSRB
7.1 : Providing and fixing in position collapsible steel shuttures
with single or double leaf with verticle channel 20mmX10mmX2mm
braced with flat iron diagonals 20mmX5mm size, with top and bottam
rails of T iron sections of 40X40X6mm with 38mmdia steel pulleys
complete with bolt and nuts, locking arrangements, stoppers,
handles on both sides with 7.5cms openings at 10cms. c to c
applying a priming coat of red lead paint. cost of materials,
labour, HOM of machinery complete as per specifications.size of
gate 2.4mX 1.40m Specification No. KBS 7.7/7.12Specification No.
KBS 7.7/7.12 (PWD DSR 2013-14 It No.7.1 P No.36)Main
Door33.003.2028.80sqm4051.00116668.8011KSRB 7.17: Providing,
fabricating, assembling and fixing in position anodized aluminium
doors using following aluminium mat finish or glossy finish, outer
frame plain section101.6x44.45mm thickness 3.18mm, section weight
2.404 kg/m, door shutters vertical section 44.62x44.45mm thickness
3.18mm, section weight 1.505klg/m, top section 47.62x44.45mm
thickness 3.00 mm, section weight 1.426kg/m bottom section
114.3x44.45 thickness 3.18mm, section weight 2.646kg/m door central
section 49.91x44.45mm thickness 3.00mm, section weight 1.495 kg/m
glazing clips 19x17.3x11mm thickness 0.9mm section weight
0.124kg/m; aluminium sections anodized 12 to 15 microns cut to
length joint metred corners grinded, the shutters pivoted opening
arrangement with heavy duty aluminium alloy automatic door closures
floor mounted, providing and fixing standard approved accessories,
such as aluminium handle for full width or length, tower bolts,
lock, pivots PVC or rubber gasket with 5.5m thick plain glass for
top and bottom panel aluminium sections treated for removal of any
rust and prevetnion of further rust formation, and coated with
greasy materials for non adherence of mortars or any other sticky
materials; the7.17Sqm4329assembled frame fitted with the corner
angles, strips and fitted with screws, rawl plugs or teakwood
gutties to R.C.C. columns or masonry on sides beams and flooring in
bottom including cutting, chistling and making good with cement
mortar to match the surface; all the frames throughly cleaned free
from rust, scale, or dirt including cost of materials, fixtures,
labour and HOM of machinery complete as per specifications. (PWD
DSR 07-08 It. No. 7.17, P. No. 41)Main
Door41.502.9017.40Sqm5879.00102294.6012PROVIDING & FIXING DOOR
FRAMEProviding Honne wood frames of doors, windows, clerestory
windows ventilators and other frames, wrought, framed or assembled
including making plaster groves (excluding cost of cement concrete
and side clamps), but including cost of materials, labour,HOM of
machineries with all lead and lift, including cost and conveyance
of all materials, labour, all other incidental charge etc.,
complete as per specification and as directed by the
engineer-in-charge of work,(PWDSR 2013-14 P-55 L-9.11)For Gents
Toilet (Ground Floor)355.600.10.081.47For Gents Toilet (First
Floor)505.600.10.082.10For Ladies Toilet (Ground
Floor)415.600.10.081.72For Ladies Toilet (First
Floor)415.600.10.081.727.01cum81044.00568442.6213PROVIDING &
FIXING DOOR Shutter40600010000KSRB 9.5-1 Providing and fixing in
position fully panelled Hone wood shutters for door, style and
rails of 40mm.thick with bottom and rock rails 180mm wide top rails
and styles 100mm wide as per drawing and panels of 25mm thick
including cost of materials, labours, HOM of machineries complete
as per Specification with all lead and lifts and as per the
direction of Engineer-in-charge.Specification No KBS 9.34KSRB
2010-2011 It No 9.15 P No.56For Gents Toilet (Ground
Floor)350.802.1058.80For Gents Toilet (First
Floor)500.802.1084.00For Ladies Toilet (Ground
Floor)410.802.1068.88For Ladies Toilet (First
Floor)410.802.1068.88Total Qty280.56Sqm3707.001040035.92For
Fixtures (Add 10% of Total cost)104003.5914KSRB 7.12 : Providing
and fixing in position anodized aluminum windows and ventilators as
per approved drawings with sliding shutters using four track window
framwe of size 122.2X31.75mm.for bottom section 1.1mm thick, weight
1.205kg/m: sides and top sections 1.2mm. thick weight 1.093 kg/m:
shutter section comprising top and bottom section of size 40mm X
18mm wall thickness 1.25mm. weight 0.417kg/m, shutter side outeer
40mmX 18mm wall thickness 1.25mm weight 0.417kg/m, shutter inerlock
sections 40mm X26.7mm wall thickness 1.1mm weight 0.469 kg/m,
shutters mouunted on nylonrollers with approved quality of fixtures
suck as aluminuun handles, tower boolts etc, providing and fixing
5.5 mm. thick plain glass for shutters fitted with rubber beading
aluminium sections anodised 12 to 15 microns, including cutting to
requried length , joint mitred subdividing the frame. tenonned and
rivetted in the assembled frame to be frame to be stiffened with
end clips at cormers,angle etc, fixed to the walls intels,
floorbeams, cills, as the case may be with necessary steel screw s,
raul plugs, or teak wood gatties including cutting masonary or
concrete and making good the original surface using cement mortar:
aluminium sections pretreated of removal of any rust and coated
with greasy materials for non adhesion of mortar and other sticky
materials,(this coating should be cleaned after installation)
including cost of materials, foxtures, labour and HOM of machinery
complete as per specification. ( PWP& IWTD 2013-14, P.No 39.
It,No.7.12V1630.628.8028.80Sqm326193916.8015KSRB 7.9 : Providing
and fixing M.S. grill work of windows and ventilators weighing 21
kg/sqm using M.S flats, or M.S. square rods, or combination of M.S.
flats and square rods as per approved design, drawing including
cutting steel sections and welding the same to required pattern
with a coat of red lead primer, cost of materials, fixtures, labour
and HOM of machinery complete as per specifications. Specification
No. KBS 7.12 (PWD DSR 2013-14 It. No. 7.9, P. No. 37)V28.80Total
Qty28.8028.80 at 21kg/sqm604.80Kgs89.4954123.5516Plaster inner
sideKSRB 15-3.10 :Providing 20mm thick cement plaster in single
coat with cement mortar 1:4, to stone masonry and concrete surrface
including rounding off corners wherever required smooth rendering,
:Providing and removing scaffolding, including cost of materials,
labour, curing complete as per specifications. (PWD DSR 2013-14 It.
No. 15.19, P. No. 123)Outer Wall Full Length1140.643.2450.05Inner
Wall222.383.2143.23Inner Wall19.463.230.27Inner
Wall44.33.255.04Inner Wall11.523.24.86Deduction of
OpeningGate133.2-9.60Door D141.22.1-10.08Door
D221.52.1-6.30Ventilatar1630.6-28.80For Ground FloorNet
Qty628.68Outer Wall Full Length1140.643.2450.05Inner
Wall222.383.2143.23Inner Wall19.463.230.27Inner
Wall44.33.255.04Inner Wall11.523.24.86Deduction of OpeningDoor
D145.40.234.968Door D225.70.232.622Ventilatar167.20.2326.496For
First FloorNet Qty717.54Total Qty of Ground Floor & First
Floor1346.22Sqm174.00234241.93For Parapet Wall (Full
Length)11400.75105.00Sqm174.0018270.0017Plaster Out sideKSRB
15-3.10 :Providing 20mm thick cement plaster in single coat with
cement mortar 1:3, to stone masonry and concrete surrface including
rounding off corners wherever required smooth rendering, :Providing
and removing scaffolding, including cost of materials, labour,
curing complete as per specifications. (PWD DSR 2013-14 It. No.
15.18, P. No. 123)Outer Wall Full Length1140.643.2450.048For Ground
FloorNet Qty450.048Outer Wall Full Length1140.643.2450.048For First
FloorNet Qty450.048Total Qty of Ground Floor & First
Floor900.10Sqm196.00176418.82For Parapet Wall (Full
Length)1140.460.75105.35Sqm196.0020647.6218C.C 1:3:6 for
FlooringKSRB 4-1.7 : Providing and laying in position plain cement
concrete of nominal mix M10 With OPC cement @ 220Kgs, with 40mm and
down size graded granite metal coarse aggregates @0.892 cum and
fine aggregate @0.465cum machin mixed, concrete laid in layers not
exceeding 15 cms. Thick, well compacted, in foundation and plinth,
including cost of all materials, labour, HOM of machinery, curing
complete as per specifications. specificationsNo-KSB 4.1,4.2(PW,P
& IWTD,Gulbarga circle Gulbarga. 2013-14 It. No. 4.2, P. No.
12)For Gents Toilet122.899.780.1022.39For Ladies
Toilet122.894.270.109.77For Ladies Toilet119.742.840.105.61For
Ladies Toilet17.124.80.103.42For Ladies Toilet12.742.820.100.77For
Ladies
Toilet16.583.230.102.13Passage120.1130.106.03Passage12.233.60.100.80Cooking
Hall114.64.30.106.28Cooking Hall14.36.50.102.80Store
Room14.122.820.101.16Deduction of
WC590.450.60-15.9345.22Cum4098.00185323.3219vetrified
tilesProviding vitrified tiles 60 x 60cms of approved make, shade
and size for flooring laid on a bed of 12mm thick cement mortar 1:3
mix, flush pointing with white cement using colour pigment,
including cost of materials, labour, curing complete as per
specifications. (PWD DSR 2013-14 It. No. 14.45, P. No. 116For
Ground floor Ladies Toilet1196.32For Ground floor Gents Toilet 1/2
Portion1107.00For Ground floor Gents Toilet 1/2 Portion198.86For
Ground Floor Passage Area1175.21For First Floor Ladies
Toilet1196.32For First Floor Gents Toilet1107.00For First Floor
Gents Toilet198.86For First Floor Passage
Toilet175.21954.78DeductionPartion WallFor Toilet Block ( Gents)
Main26.20.115-1.43For Toilet Block ( Gents) (WC)2420.115-5.52For
Toilet Block ( Gents) ( Bath)1020.115-2.30For
HWC14.950.115-0.57Urinals61.30.115-0.90For Toilet Block ( Ladies)
Main113.420.115-1.54For Ladies Toilet (Bath and WC)1620.115-3.68For
Ladies Toilet (Bath )11.330.115-0.15For Ladies Toilet (Bath and
WC)181.90.115-3.93For Ladies Toilet (Bath and WC)61.90.115-1.31For
cooking Hall114.580.115-1.68For cooking Hall17.770.115-0.89For
cooking Hall23.350.115-0.77For cooking Hall53.280.115-1.89For
Ground Floor000.1150.00For First Floor000.1150.00For Toilet Block (
Gents) Main26.20.115-1.43For Toilet Block ( Gents)
(WC)2420.115-5.52For Toilet Block ( Gents) ( Bath)1020.115-2.30For
HWC14.950.115-0.57Urinals61.30.115-0.90For Toilet Block ( Ladies)
Main113.420.115-1.54For Ladies Toilet (Bath and WC)1620.115-3.68For
Ladies Toilet (Bath )11.330.115-0.15For Ladies Toilet (Bath and
WC)181.90.115-3.93For Ladies Toilet (Bath and
WC)61.90.115-1.31Total
Qty-47.89WC1340.450.60-36.18870.71Sqm1115.00970839.7020KSRB 14.
10-1 : Flooring with 25mm to 40mm thick polished tandur blue stone
slabs using cement mortar 1:6, 25mm thick over existing cement
concrete bed or top of roof laid to line and level and jointed with
cement slurry mixed with pigment to match the shade of hte slab,
including cost of materials, labour, curing, polishing complete as
per specifications. Specification No. KBS. (PWD DSR 2013-14 It. No.
14.15, P. No. 112)For Ground Floor - Cooking
Hall1145.00Sqm941.00136445.00For First Floor - Cooking
Hall1145.00Sqm941.00136445.0021Viterfied tiles for
claddingProviding flooring with 60 cms.x 60 cms size vitrified
glazed tiles of approved quality and make, fixed on top of existing
flooring fixed with suitable adhesive, including cutting the tiles
to the required size and fixing etc., complete. (PWD DSR 2013-14
It. No. 14.44, P. No. 116)Outer Wall Full
Length1140.641.5210.96Inner Wall222.381.567.14Inner
Wall19.461.514.19Inner Wall44.31.525.80Inner
Wall11.521.52.28Deduction of OpeningGate131.5-4.50Door
D141.21.5-7.20Door D221.51.5-4.50For Ground Floor304.17Outer Wall
Full Length1140.641.5210.96Inner Wall222.381.567.14Inner
Wall19.461.514.19Inner Wall44.31.525.80Inner
Wall11.521.52.28Deduction of OpeningDoor D141.21.5-7.20Door
D221.51.5-4.50For First Floor308.67For Portion WallFor Toilet Block
( Gents) Main26.21.518.60For Toilet Block ( Gents)
(WC)2421.572.00For Toilet Block ( Gents) ( Bath)1021.530.00For
HWC14.951.57.43Urinals61.31.511.70For Toilet Block ( Ladies)
Main113.421.520.13For Ladies Toilet (Bath and WC)1621.548.00For
Ladies Toilet (Bath )11.331.52.00For Ladies Toilet (Bath and
WC)181.91.551.30For Ladies Toilet (Bath and WC)61.91.517.10For
cooking Hall114.581.217.50For cooking Hall17.771.29.32For cooking
Hall23.351.28.04For cooking Hall53.281.219.68For Ground FloorFor
First FloorFor Toilet Block ( Gents) Main26.21.518.60For Toilet
Block ( Gents) (WC)2421.572.00For Toilet Block ( Gents) (
Bath)1021.530.00For HWC14.951.57.43Urinals61.31.511.70For Toilet
Block ( Ladies) Main113.421.520.13For Ladies Toilet (Bath and
WC)1621.548.00For Ladies Toilet (Bath )11.331.52.00For Ladies
Toilet (Bath and WC)181.91.551.30For Ladies Toilet (Bath and
WC)61.91.517.10Total Qty of Partion Wall611.04Net
Qty1223.88Sqm1226.001500476.8822O.B.D on ceiling & wallKSRB
15-14.1 : Providing and applying two coats with oil bound washable
distemper of approved brand and shade on wall surface including
priming coat with distemper primer after throughly brooming the
surface free from mortar drops and other foreign matter including
preparing the surface even and sand paper smooth, cost of
materials, labour, complete as per specifications. (PWD DSR 2013-14
It. No. 15.49.1, P. No. 126)Outer Wall Full
Length1140.641.7239.09Inner Wall222.381.776.09Inner
Wall19.461.716.08Inner Wall44.31.729.24Inner Wall11.521.72.58For
Ground Floor363.09Outer Wall Full Length1140.641.7239.09Inner
Wall222.381.776.09Inner Wall19.461.716.08Inner
Wall44.31.729.24Inner Wall11.521.72.58For First Floor363.09For
Portion WallFor Toilet Block ( Gents) Main26.20.637.81For Toilet
Block ( Gents) (WC)2420.6330.24For Toilet Block ( Gents) (
Bath)1020.6312.60For HWC14.950.633.12For Toilet Block ( Ladies)
Main113.420.638.45For Ladies Toilet (Bath and WC)1620.6320.16For
Ladies Toilet (Bath )11.330.630.84For Ladies Toilet (Bath and
WC)181.90.6321.55For Ladies Toilet (Bath and WC)61.90.637.18For
cooking Hall114.581.217.50For cooking Hall17.771.29.32For cooking
Hall23.351.28.04For cooking Hall53.281.219.68For Ground
Floor166.49For First FloorFor Toilet Block ( Gents)
Main26.20.637.81For Toilet Block ( Gents) (WC)2420.6330.24For
Toilet Block ( Gents) ( Bath)1020.6312.60For HWC14.950.633.12For
Toilet Block ( Ladies) Main113.420.638.45For Ladies Toilet (Bath
and WC)1620.6320.16For Ladies Toilet (Bath )11.330.630.84For Ladies
Toilet (Bath and WC)181.90.6321.55For Ladies Toilet (Bath and
WC)61.90.637.18Total Qty of Partion Wall111.95For
Celling1254.18Total Qty2258.7986Sqm55.55125476.2623Enamel PaintKSRB
15-18.2 : Providing and applying enamel metal paint two coats
(exluding priming coat) over new steel or other metal surface
brushing to give an even shade after cleaning oil, graease, dirt
and other foreign matter, including cost of materials, labour,
complete as per specifications. (PWD DSR 2013-14 It. No. 15.74, P.
No. 130)Main Door333.228.80V16300.628.857.60Sqm71.844137.9824Water
Proof PaintingKSRB 15-16 : Providing and finishing external walls
in two coats with water proof cement paint of approved bran and
shade to give an even shade after throghly brooming the surface to
remove all dirt and loose powdered material, free from mortar drops
and other foreign matter cost of materials, labour, complete as per
specifications. (PWD DSR 2013-14 It. No. 15.53, P. No. 127) do with
primer ( item No 15.53.2) Page No 127Outer Wall Full
Length1140.648.71223.5681223.57Sqm62.0075861.2225Stainless steel
english Letters2323.00Each500.0011500.0014038273.2714433593.27For
Water Supply and Sanitation1789564.9815827838.2416197838.24
water Supply and sanitationSub Estimate 2 :-Water Supply and
Sanitation for Toilet Block at Dargah Hazarath Khwaja Banda Nawaz
(RH) at Gulbarga.Sl. No.Particulars of workNoL (m)B (m)D
(m)QtyUnitRate (Rs)Amount (Rs)1EXCAVATIONKSRB 2-2.2 : Earthwork
excavation for foundation of buildings, water supply, sanitary
lines and electrical conduits either in pits or in trenches 1.5m
and above in width, in hard soil not exceeding 1.5 m. in depth
including dressing the bottom and sides of pits and trenches,
stacking the excavated soil clear from edges of excavation with
lead upto 50 m. after breaking of clods complete as per
specifications. Specification No. KBS 2.1(b)/2.3.5 (PWD DSR 2013-14
It. No. 2.4, P. No. 5)Raising
main1250.000.500.5062.50Cum209.0013062.502RefillingKSRB 2-4:
Refilling available earth around pipe lines, cables in layers not
exceeding 20cms in depth, compacting each deposited layer by
ramming after watering with lead upto 50m. and lift upto 1.5m.
including cost of all labour complete as per specifications allow
60% of rate considered under item KSRB 2.3. (PWD DSR 2013-14 It.
No. 2.11, P. No. 6)1250.000.500.5062.50Cum56.353521.883Polyethylene
pipeKSRB 13-9.1: Providing and fixing to wall, ceiling and floor
high density polyethene pipes 6.00 kgf/sq.cm working pressure 63mm
outside diamter with special flange, compression type fittings,
wall clips, making good the wall, ceiling and floor including cost
of all materials, labour charges, HOM of equipments and testing
complete as per specifications. Specification No. 13.2.15.2/13.9
(PWD DSR 13-14 It. No. 13.71, P. No.102)Rising main upto
Tank1250.00250.00Rmt250.0062500.00Add 10% for specials.6250.004KSRB
13-10.2: Providing and fixing to wall, ceiling and floor
unplasticised PVC pipes 10.00 kgf/sq.cm working pressure 32mm
outside diameter chemp plast/wavin or equivalent make with pipe
fittings, wall clips, making god the wall, ceiling and floor,
including cost of all materials, labour charges, HOM of
specification (PWD DSR 13-14 It. No. 13.77, P. No. 103)Distribution
from Tank to Toilets1250.00250.00250.00Rmt111.0027750.00Add 10% for
specials.2775.005BIB COCKKSRB 13-6.1-1 : Providing and fixing in
position brass bib cock of approved quality 15mm nominal bore
including cost of all materials, labour and HOM of equipments with
all leads complete as per specifications. Specification No. KBS
13.2.2 /13.3 (PWD DSR 2013-14 It. No. 13.23, P. No.96)Bath and
Wc164164164Each218.0035752.006Stop CockKSRB 13-6.2-2 : Providing
and fixing in position brass stop cock of approved quality 20mm
nominal bore including cost of all materials, labour and HOM of
equipments with all leads complete as per specifications.
Specifications. No. KBS 13.2.2 /13.3 (PWD DSR 2013-14 It. No. 13.27
P. No. 96)3030.00Each160.004800.007Brass gate ValveKSRB 13-6.3-1 :
Providing and fixing in position brass gate valve with C.I wheel of
approved quality (screwed end) (25,20)mm nominal bore including
cost of all materials, labour and HOM of equipments with all leads
complete as per specifications. Specification No. KBS 13.2.6 / 13.3
(Item No 13.34) (PWD DSR 2013-14 It. No. 13.34, P. No.
89)25mm204204Each580.00118320.008Providing gum metel piller cocks
15mm dia of 1 class conforming to ISI specifications and fixing
them in position as per direcrtion including of cost of materials
and fixtures and conveyance to spot.(PWP&IWTD 2013-2014 P No.
104 It No 13.80)4040Each245.009800.009KSRB 11-2 : Providing and
fixing white vitreous china clay, water closet Orrissa pattern of
size 580 X 440 mm with integral type footrests, 100mm S or Ptrap,
10 litre low level, P.V.C. flushing cistern (all are approved make)
with fittings, C.I. /M.S brackets, 32mm diameter flush bean with
fittings and clamps, overflow arrangements with special and 25mm
mosquito proof coupling of approved design, painting of fittings
and brackets, cutting and making good the wall and floor wherever
required, including cost of materials, labour complete as per
specifications. Specification No KBS 11(PW,P & IWTD,Gulbarga
circle Gulbarga 2013-14 It. No. 12.2, P. No.
78)132132Each4185.00552420.0010KSRB 11-5 : Providing and fixing
white vitreous china clay, water closet European type (Pedestal
type) with black solid plastic seat and lid, C.P. brass hinges,
rubber buffers. 10 litre low level, P.V.C. flushing cistern (all
are approved make) with fittings, C.I. /M.S brackets, 40mm diameter
flush bean with fittings and clamps, overflow arrangements with
special and 25mm mosquito proof coupling of approved design,
painting of fittings and brackets, cutting and making good the wall
and floor wherever required, including cost of materials, labour
complete as per specifications.Specification No KBS 11 (PWD DSR
2013-14 It. No. 12.5, P. No. 78)22Each4852.009704.0011KSRB 11-7.2 :
Providing and fixing white vitreous china clay, flat back, lipped
front urinal basin of 430x260x350mm. with 5 litres PVC automatic
flushing cistern, C.I./M.S brackets, standard flush pipe and C.P.
brass spreaders with brass unions and G.I. clamps complete painting
of fittings and brackets, cutting and making good the wall and
floor wherever required, including cost of materials, labour
complete as per specification. Specification No. KBS 11 (PWD
DSR2013-14 It. No. 12.8, P. No. 79)77Unit3838.0026866.0012KSRB
11-11.3 : Providing and fixing white vitreous china clay, flat back
wash basin size 550x400mm with a pair of 15mm C.P brass pillar taps
with C.I/M.S brackets, 32mm C.P. brass waste of standard pattern,
painting of fittings and brackets, cutting and making good the wall
and floor wherever required including cost of materials, labour
complete as per specifications. Specification No. KBS 11 (PWD DSR
2013-14 It. No. 12.25, P. No. 82)404Unit3402.0013608.0013Wall bores
in Brick masonry upto 45 cms thick ( item No 37.35 P No.267
DSR.2013-14164164Each57.009348.0014KSRB 11-15.3 : Providing and
fixing 453 X 357 mm dia circular shape mirror with plastic moulded
frame of approved make and shade with 6mm thick hard board backing
including cost of materials, labour complete as per specifications.
(PWD DSR 2013-14 It. No. 12.41, P. No.
84)7070Unit1135.0079450.0015KSRB 11-17.1 : Providing and fixing
C.P. brass towel rail 740mm length, 20mm dia with C.P brackets,
fixed to wooden cleats with C.P. brass screws including cost of
materials, labour complete as per specifications. (PWD DSR 2013-14
It. No. 12.45, P. No. 84)702Unit740.001480.0016Providing and laying
floor for corridors/lobbies using combination of pre polished 19mm
thick water cut/gang saw grey granite, black granite and strips of
50mm wide pre flamed grey granite using pre polished grey granite
19mm thick 76% pre polished black granite 19mm thick @ 2% and
preplamed 19mm thick grey granite @ 22% over existing cement
concrete bed in CM 1:4 aveage 20mm thick pointed with white
cement/colour pigment etc., complete. (PWD DSR 2013-14 It. No.
14.48, P. No. 115)Urinal
Portion49.711.0038.8438.84Sqm3320.00128948.8017KSRB 8.6-5:
Providing and fixing on wall surface 2.5kg/sq.cm H.D.P.E. rain down
water pipes 110mm outer dia approved make and brand with necessary
specials like shoes, bends and offsets fixed with iron clamps, wall
plugs, screws, including cost of materials, labour, curing complete
as per specifications. (PWD DSR 2013-14 It. No. 8.17 P. No.
52)127.2086.40Rmt472.0040780.80SANITATION18Providing, laying and
jointing PVC pipes of 110mm dia ( superme/ Finolex ) confirmaing to
IS 4085-1960 & 7634-1975 Specification of approved make with
necessary specials such as collars, bends, elbows, tees, nipples,
plugs with cuts and theads using jointing KUWSDB, 2013-14 Item No
6(sl No 7)For Ground Floor (185+25+50)1260.00260.00For First
Floor1130.00130.00From I/C to
MH230.0060.00450.00Rmt237.00106650.0019Providing and fixing CI
Nahani trap of approved make conforming to ISI specifications and
construction of cistern in CC 1:2:4 as per directions (Rate is
inclusive of cost of materials and fixtures and conveyance of
materials to work spot.) (PWD DSR2013-14 It. No. 12.113.2, P. No.
91)Do 12.5 cms X 7.5 cms134134.00Each270.0036180.0020Providing
stoneware gully trap of approved quality and make fixing in CC
1:2:4 and plastering with CM 1:3 wherever necessary (Rate includes
cost of all materials, fixtures and lead) (PWD DSR 2013-14 It. No.
12.112, P. No. 91)do (15cms X 10
cms)134134.00Each175.0023450.0021KSRB 12-8.1 : Constructing brick
masonry inspection chamber 455x610mm, and 450mm depth, (clear
inside dimension) for single pipeline, using table moulded
non-modular bricks of class designation 50 in cement mortar 1:5,
C.I. cover with frame (light duty) 455x610mm internal dimensions,
total weight of cover with frame to be not less than 38 kg (weight
of cover 23kg and weight of frame 15 kg) R.C.C. top slab with
cement concrete 1:2:4 mix 20mm and downsize granite metal,
foundation concrete 1:5:10 with 40mm and downsize granite metal
inside plastering 12mm thick with cement mortar 1:3, finish smooth
with a floating coat of cement on walls and bed concrete complete
as per standard design including cost of materials, labour charges,
curing complete as per specifications. (PWD DSR 2013-14 It. No.
11.50.1, P. No. 75)do- 600X600mm and 450mm
depth4141.00Nos7607.00311887.006024.0022KSRB 12-5.1 : Constructing
brick masonry circular type manhole 0.91m internal dia at bottom
0.91m deep and 0.56m dia at top with table moulded non-modular
bricks of 50 class designation 50 in cement mortar 1:4, inside
cement plastered 12mm thick with cement mortar 1:3, finished with a
floating coat of neat cement, foundation concrete M 10 using 40mm
and downsize granite metal and making necessary channel in cement
concrete M 50 with 20mm and downsize granite metal finished with a
floating coat of neat cement, with S.F.R.C. cover and frame (heavy
duty, HD-20 grade designation) 560mm internal diametre confirming
IS : 12592, total weight cover and frame to be nto less than 182
kg, fixed in cement concrete 1:2:4, 20mm and downsize broken
granite metal, providing an dremoving centering, shuttering
including cost of materials, labour charges, HOM of machineries
complete as per specifications. (Excavation, footrests and 12mm
thick cement plaster on the external surface shall be paid
seperately)99.00Nos10845.0097605.0023KSRB 13-11.1: Providing and
placing on terrace, polyethene water storage tanks with manhole lid
and suitable locking arrangements, making holes of suitable
diameter for inlet, outlet and over flow pipes, including cost of
all materials, labour, transport charges, HOM of equipments and
testing complete as per specifications. (For 1000 litr capacity)
Specification No. KBS 13.22 (PW,P &IWTD GULB 2013-14 P.No103
It.No, 13.7888.00Nos.8332.0066656.00Grand
total1789564.988.99217.9838400.0014.61114.61100000.004.1114.1116336238.242.3924.782.54512.702.54512.702.151123.6523.92123.923.2326.467.06321.182.541230.482.5712.579.8519.85184.99111
Est KBN Toilet block (2)Sub Estimate 3 : - Electrical Estimate
for Proposed Toilet and Kitchen Block at Dargah at Hazrat Khwaja
Banda Nawaz (Rh) at Gulbarga.Sl.
No.ParticularsUnitQtyRateAmountConcealed Conduit System:1Supplying
19/20mm dia 2mm/2.5mm thick heavby gauge PVC conduit pipe with
suitable size bends, metal/PVC junction boxes adhesive paste etc.,
and running before concreting the slab. The conduit should be tied
to the reinforcement rods by sing binding wires and unused ways of
junction boxes and pipe ends should be covered using PVC end
enclosures, run with 18SWG GI fish wire wherever necessary.RA 1Per
Mtr65032.0020,800.002b) 25 mm dia 2mm thickPer
Mtr28041.0011,480.00RA 23Groove cuttingin in the wall supplying
19/20mm dia 2mm/2.5mm thick heavby gauge PVC conduit pipe with
suitable size bends, metal/PVC junction boxes adhesive paste etc.,
and bracing U or J hooks and cement plastering up to the surface of
the brick level and run with 18 SWG GI fish wire run through out
the conduit wherever necessary.Per Mtr70.0043.003,010.00RA 34b) 25
mm dia 2mm thickPer Mtr4053.002,120.00RA 45Supplying and flush
molunting teak wooden box without front plank, made of not less
than 12 mm thick wood, after due goove cutting, necessary masonry
patch work complete.12x"12"x3"
(300x300x76mm)Each1098.00980.00540000RA 5612x"9"x3"
(300x228x76mm)Each680.00480.00273,600.00RA 6710x"7"x3"
(254x178x76mm)Each668.00408.00180,848.00RA 788x"6"x3"
(203x152x76mm)Each652.00312.00123,424.00RA 894x"4"x3"
(101x101x76mm)Each1244.00528.00102,010.00RA
9679,882.00680010Supplying and wiring adopting loop system in
existing PVC conduit/casing capping using copper PVC insulated
multistrand 2 x 1.5 Sq.mm copper wire with a 6 Amps flush type SP
control switch shall be fixed on the exisiting plastic sheet/gang
box, the other end of the wires shall be terminated with sufficient
loose length in a wood/PVC round block complete for each
outlet.Point14175.002,450.00Short point upto 3 Mtr from tapping
point to out let via switch.RA 1011Medium point above 3 Mtr upto 6
Mtr from tapping point to outlet via
switch.Point95260.0024,700.00RA 1112Long point above 6 Mtr upto 10
Mtr from tapping point to outlet via
switch.Point46368.0016,928.00RA 1213Supplying and fixing PBBC
bakelite straigh or slant batten holder.Point16038.006,080.00RA
1314Supplying 6 Amps 3/5 way flush/projected type socket and 6 amps
flush/projected type SP switch either surface/flush mounting in a
existing gang box or in a 4 mm thick plastick sheet and fixing over
a flush mounted wooden box and wiring using necessary caopacity
wires as required.Each18106.001,908.00RA 1415Supplying and mounting
2 Nos. of 2 way 6 amps flush type switches either surfface/flush
mounted on exising gang box or in 4mm thick plastic sheet and
mounted on a flush mounted wooden box and wiring as
required.Each891.00728.00RA 1516Wiring for lighting/power circuit
using one of PVC insulated 1 Sq. mm, 1100V grade, multis and Copper
conductor single core cable in open or consealed system of
wiringPer Mtr65011.007,150.00RA 17017c) 2.5 sqmm.Per
Mtr150025.0037,500.00RA 18184 sqmm.Per Mtr30032.009,600.00RA
1919Supplying 4mm thick plastick sheet with necessary nitches for
fixing switches regulators etc., and fixing on existing wooden or
metal box using N.F. screws.Sq cm69500.221,529.00RA 2020Supplying
and fixing cast Aluminium round or oblong type bulk head fitting
with GI wire guard, glass cover with 60/100 walts 230V GLS lamp as
required.Each9604.005,436.00RA 2121Supplying patty type fluorescent
tube light fitting of 4'- 36/40 watts fluorescent tube fitting,
made out of M.S sheet and stove enameled with low loss open
construction copper wound ferromagnetic ballast, starter, locking
type brass contact holders mounted on double fold type sheet base
fuly wired for use on 230 Volts A C Supply including 1No. 4'-36/4
Watts fluorescent tube.Each100400.0040,000.00RA 2222Supplying 250
Watts High pressure sodium vapour street light fitting die cast
aluminium canopy with aluminium housing for control gear, finished
stove enamel gray glassy white canopy interior with a pair of
anodized aluminium reflectors clear acrylic blow, gasket lining for
drip inseat resistance duly wired with porcelain holder copper
choke, igniter and HPF condenser including a sodium vapour
lamp.Each36,150.0018,450.00RA 2323Supplying of 12" Sweep1440rpm
heavy duty exahust fan with bracket blades suitable for operate on
230V 50Hz, AC Supply complete.Each352,500.0087,500.00RA
2424Supplying capacitor type 48" Sweep (1200 mm) ceiling fan
complete with down road blades, shakle, canopies ertc., for
operation on 230 volts, 50 cycles, single phase AC supply
conforming to ISS - 374 - 1979 and with double ball rearing
system.Each121,800.0021,600.00RA 2525Supplying and fixing 32 mm dia
class A GI Pipe bracket upto 2.7 meters long for fixing
MV/SV/MH/FTL street light fitting of all capacities on
rail/RCC/wall/tublar pole, using suitable clapms, bolts and nuts
and wiring using suitable cpacity wires etc.
complete.Each3885.002,655.00RA 2626Fixing all types and all
capacities fluorescent/false ceiling/spot light/CFL fittings indor
on the wall/seiling/rafters/girders using 23/0.0076" twin twisted
PVC insulated wires, required nos of round blocks and clamps (if
required)Each100105.0010,500.00RA 2727Fixing a ceiling/Wall
mounting fan of all capacities and all types with necessary clamps
and S hook made out of 15 mm dia MS rod, with a 5 amps ceiling rose
of approved quality with necessary length of 23/0.0076 inch PVC
insulated twin twisted wire of approved quality with regulator
mounted on a suitable size wooden board and wired
complete.Each12210.002,520.00RA 2828Fixing one exhaust fan in the
nitch already left in the with bolts and nuts and 5 amps ceiling
rose with sufficient lingth of 23/0.0076 inch PVC insulated twin
core wire of approved make.Each35310.0010,850.00RA 2929Supplying of
63 A TPST with rewirable porcelain channels in SM sheet
enclosure.Each23,050.006,100.00RA 3030Supplying of 100 A TPST with
rewirable porcelain channels in SM sheet
enclosure.Each15,400.005,400.00RA 3131Fixing of 15 Amps to 63 TPST
/ change over switch / contactor along with neutral link with
screws, bolts, nuts and wiring using required capacity wires and
circuit lableling.Each2165.00330.00RA 3232Fixing of 100 Amps to 250
TPST / change over switch / contactor along with neutral link with
screws, bolts, nuts and wiring using required capacity wires and
circuit lableling.Each1500.00500.00RA 3333Supplying and fixing 20"
x 20" x 2.5" polished wood board made of not less than 15 mm thick
plank on bth sides with planks made out of not more than 2 pieces
and fixing the same to the wal using tapered invertred wooden plugs
screws etc.Each1285.00285.00RA 3434Supplying and fixing 12 Way
regular MCCB distribution panel confirm tgo IS 8828, on
wall/woodboard/flush mounting using required clamps, bolts, nuts
etc., with provision for fixing of suitable type capacity MCCB's as
an incomer of 3 phase Double door with necessary busbar completely
wired to use on 440 Volts 3 phase 4 wire powder coated painting
etc., complete with a rpovision for fixing of single / three phase
suitable capacity MCCB/MCB's as outgoings confirm to
IS8825.Each47,640.0030,560.00RA 3535Supplying and fixing 32 Amps DP
miniature circuit breakers on existing MCB distribution boards
using necessary fixing materials and wiring complete as
requiredEach20510.0010,200.00RA 3636Supplying, fixing and wiring
electronic 10 to 40 Amps three phase 4 wire class - 1 Accuracy
Energy Meter.Each14,120.004,120.00RA 3737Supplying, fixing, wiring,
earth electrode for grounding conduits, IC cutouts and other
equiments on the meter board using 40 mmdia 2.90 hick GI pipe 2.5
mtr long buried in a pit . The pit should be filled with equal
proportion of salt and charcoal 150 mm alround the pipe to complete
the depth. The connection from the pipe to the conduit etc. is to
be established through GI wire of size as per ISI specification
7.3.3 of IS 732 using 12 mm dia bolts, nuts, washers and check nuts
etc., the pipe shall have 16 through holes of 12 mm
dia.No61,950.0011,700.00RA 3838Supplying and running 8 SWG GI
conductor for grounding and (along with other wires in conduit
system of wiring) using necessary suitable size clamps, nails,
guttas/spacers etc.Per Mtr6020.001,200.00RA 3939Supplying of 3.5
core x 25 Sq. mm LT UG cable having aluminium conductor PVC
insulated, sheathed, galvanised, steel wire/steel tap armoured
cable with PVC outer sheathing 1.1 KV classPer
Mtr80215.0017,200.00RA 4040Labour charges for laying of 3.5 core x
25 Sq. mm, 1.1 KV/class UG cable when supplied agency in existing
trench GI pipe / stoneware pipe / on wall / on pole as required.R
Mtr8011.00880.00RA 4141Digging of trench of in Soil (hard), 0.6m
deep x 0.50 mtr wide refiling the trench to the required ground
level and consolidating etc., complete. (As per Civil SR KSRB 1-2,
P-7)R Mtr5050.002,500.00RA 42Total Rs.439,177.00
RA KBN Toilet blockElectrical Rate Analaysis of Proposed Toilet
and Kitchen Block at Dargah at Hazrat Khwaja Banda Nawaz (Rh) at
Gulbarga.Sl. No.ParticularsUnitRate1Concealed Conduit
System:Supplying 19/20mm dia 2mm/2.5mm thick heavby gauge PVC
conduit pipe with suitable size bends, metal/PVC junction boxes
adhesive paste etc., and running before concreting the slab. The
conduit should be tied to the reinforcement rods by sing binding
wires and unused ways of junction boxes and pipe ends should be
covered using PVC end enclosures, run with 18SWG GI fish wire
wherever necessaryPer Mtr32.00a) 19/20mm dia 2mm thickPWD SR 10 -
11 Pg No. 2 It.No. 2(a)Basic Rate32.00Add : AW0.0Sub- Total32.002b)
25 mm dia 2mm thickPer Mtr41.00PWD SR 10 - 11 Pg No. 2 It.No.
2(b)Basic Rate41.00Add : AW0.0Sub- Total41.003Groove cuttingin in
the wall supplying 19/20mm dia 2mm/2.5mm thick heavby gauge PVC
conduit pipe with suitable size bends, metal/PVC junction boxes
adhesive paste etc., and bracing U or J hooks and cement plastering
up to the surface of the brick level and run with 18 SWG GI fish
wire run through out the conduit wherever necessary.Per Mtr43.00a)
19/20mm dia 2mm thickPWD SR 10 - 11 Pg No. 2 It.No. 3(a)Basic
Rate43.00Add : AW0.0Sub- Total43.004b) 25 mm dia 2mm thickPer
Mtr53.00PWD SR 10 - 11 Pg No. 2 It.No. 2(b)Basic Rate53.00Add :
AW0.0Sub- Total53.005Supplying and flush molunting teak wooden box
without front plank, made of not less than 12 mm thick wood, after
due goove cutting, necessary masonry patch work
complete.Each98.00a) 12x"12"x3" (300x300x76mm)PWD SR 10 - 11 Pg No.
3 It.No. 6(a)Basic Rate98.00Add : AW0.0Sub- Total98.006b) 12x"9"x3"
(300x228x76mm)Each80.00PWD SR 10 - 11 Pg No. 3 It.No. 6(b)Basic
Rate80.00Add : AW0.0Sub- Total80.007c) 10x"7"x3"
(254x178x76mm)Each68.00PWD SR 10 - 11 Pg No. 3 It.No. 6(c)Basic
Rate68.00Add : AW0.0Sub- Total68.008d) 8x"6"x3"
(203x152x76mm)Each52.00PWD SR 10 - 11 Pg No. 3 It.No. 6(d)Basic
Rate52.00Add : AW0.0Sub- Total52.009e) 4x"4"x3"
(101x101x76mm)Each44.00PWD SR 10 - 11 Pg No. 3 It.No. 6(e)Basic
Rate44.00Add : AW0.0Sub- Total44.0010Supplying and wiring adopting
loop system in existing PVC conduit/casing capping using copper PVC
insulated multistrand 2 x 1.5 Sq.mm copper wire with a 6 Amps flush
type SP control switch shall be fixed on the exisiting plastic
sheet/gang box, the other end of the wires shall be terminated with
sufficient loose length in a wood/PVC round block complete for each
outlet.Point175.00Short point upto 3 Mtr from tapping point to out
let via switch.PWD SR 10 - 11 Pg No. 3 It.No. I(a)Basic
Rate175.00Add : AW0.0Sub- Total175.0011Medium point above 3 Mtr
upto 6 Mtr from tapping point to outlet via switch.Point260.00PWD
SR 10 - 11 Pg No. 3 It.No. I(b)Basic Rate260.00Add : AW0.0Sub-
Total260.0012Long point above 6 Mtr upto 10 Mtr from tapping point
to outlet via switch.Point368.00PWD SR 10 - 11 Pg No. 3 It.No.
I(c)Basic Rate368.00Add : AW0.0Sub- Total368.0013Supplying and
fixing PBBC bakelite straigh or slant batten holder.Point38.00PWD
SR 10 - 11 Pg No. 50 It.No. 34I(f)Basic Rate38.00Add : AW0.0Sub-
Total38.0014Supplying 6 Amps 3/5 way flush/projected type socket
and 6 amps flush/projected type SP switch either surface/flush
mounting in a existing gang box or in a 4 mm thick plastick sheet
and fixing over a flush mounted wooden box and wiring using
necessary caopacity wires as required.Each106.006 Amps 3/5 wayPWD
SR 10 - 11 Pg No. 6 It.No. 12(b)Basic Rate106.00Add : AW0.0Sub-
Total106.0015Supplying and mounting 2 Nos. of 2 way 6 amps flush
type switches either surfface/flush mounted on exising gang box or
in 4mm thick plastic sheet and mounted on a flush mounted wooden
box and wiring as required.Each91.00PWD SR 10 - 11 Pg No. 6 It.No.
13Basic Rate91.00Add : AW0.0Sub- Total91.0016Wiring for
lighting/power circuit using one of PVC insulated 1100V grade,
multis and Copper conductor single core cable in open or consealed
system of wiringPer Mtr11.001 sqmm.11PWD SR 10 - 11 Pg No. 9 It.No.
20(I)(a)Basic Rate11.00Add : AW0.0Sub- Total11.0017c) 2.5 sqmm.Per
Mtr25.00PWD SR 10 - 11 Pg No. 9 It.No. 20(I)(c)Basic Rate25.00Add :
AW0.0Sub- Total25.00184 sqmm.Per Mtr32.00PWD SR 10 - 11 Pg No. 9
It.No. 20(I)(d)Basic Rate32.00Add : AW0.0Sub- Total32.0019Supplying
4mm thick plastick sheet with necessary nitches for fixing switches
regulators etc., and fixing on existing wooden or metal box using
N.F. screws.Sqcm0.22PWD SR 10 - 11 Pg No. 10 It.No. 22Basic
Rate0.22Add : AW0.0Sub- Total0.2220Supplying and fixing cast
Aluminium round or oblong type bulk head fitting with GI wire
guard, glass cover with 60/100 walts 230V GLS lamp as
required.Each604.00PWD SR 10 - 11 Pg No. 13 It.No. 5(a)Basic
Rate604.00Add : AW0.0Sub- Total604.0021Supplying patty type
fluorescent tube light fitting of 4'- 36/40 watts fluorescent tube
fitting, made out of M.S sheet and stove enameled with low loss
open construction copper wound ferromagnetic ballast, starter,
locking type brass contact holders mounted on double fold type
sheet base fuly wired for use on 230 Volts A C Supply including
1No. 4'-36/4 Watts fluorescent tube.Each400.00a) Group 'A'PWD SR 10
- 11 Pg No. 16 It.No. 2(a)Basic Rate400.00Add : AW0.0Sub-
Total400.0022SupplyingHigh pressure sodium vapour street light
fitting die cast aluminium canopy with aluminium housing for
control gear, finished stove enamel gray glassy white canopy
interior with a pair of anodized aluminium reflectors clear acrylic
blow, gasket lining for drip inseat resistance duly wired with
porcelain holder copper choke, igniter and HPF condenser including
a sodium vapour lamp.Each6,150.00II 250 Wattsa) Group 'A'PWD SR 10
- 11 Pg No. 19 It.No. 12(II)(a)Basic Rate6,150.00Add : AW0.0Sub-
Total6,150.0023Supplying of 12" Sweep1440rpm heavy duty exahust fan
with bracket blades suitable for operate on 230V 50Hz, AC Supply
complete.Each2,500.00PWD SR 10 - 11 Pg No. 23 It.No. 22I(a)Basic
Rate2,500.00Add : AW0.0Sub- Total2,500.0024Supplying capacitor type
48" Sweep (1200 mm) ceiling fan complete with down road blades,
shakle, canopies ertc., for operation on 230 volts, 50 cycles,
single phase AC supply conforming to ISS - 374 - 1979 and with
double ball rearing system.Each1,800.00PWD SR 10 - 11 Pg No. 23
It.No. 23(I)(a)Basic Rate1,800.00Add : AW0.0Sub-
Total1,800.0025Supplying and fixing 32 mm dia class A GI Pipe
bracket upto 2.7 meters long for fixing MV/SV/MH/FTL street light
fitting of all capacities on rail/RCC/wall/tublar pole, using
suitable clapms, bolts and nuts and wiring using suitable cpacity
wires etc. complete.Each885.00b) Using 32mm dia G.I. pipePWD SR 10
- 11 Pg No. 28 It.No. 2(b)Basic Rate885.00Add : AW0.0Sub-
Total885.0026Fixing all types and all capacities fluorescent/false
ceiling/spot light/CFL fittings indor on the
wall/seiling/rafters/girders using 23/0.0076" twin twisted PVC
insulated wires, required nos of round blocks and clamps (if
required)Each105.00a) On wall/ceiling/Rafters/Girders.PWD SR 10 -
11 Pg No. 29 It.No. 7(a)Basic Rate105.00Add : AW0.0Sub-
Total105.0027Fixing a ceiling/Wall mounting fan of all capacities
and all types with necessary clamps and S hook made out of 15 mm
dia MS rod, with a 5 amps ceiling rose of approved quality with
necessary length of 23/0.0076 inch PVC insulated twin twisted wire
of approved quality with regulator mounted on a suitable size
wooden board and wired complete.Each210.00PWD SR 10 - 11 Pg No. 29
It.No.9Basic Rate210.00Add : AW0.0Sub- Total210.0028Fixing one
exhaust fan in the nitch already left in the with bolts and nuts
and 5 amps ceiling rose with sufficient lingth of 23/0.0076 inch
PVC insulated twin core wire of approved make.Each310.00PWD SR 10 -
11 Pg No. 29 It.No.12Basic Rate310.00Add : AW0.0Sub-
Total310.0029Supplying of 63 A TPST with rewirable porcelain
channels in SM sheet enclosure.Each3,050.00PWD SR 10 - 11 Pg No. 32
It.No.1(b)Basic Rate3,050.00Add : AW0.0Sub-
Total3,050.0030Supplying of 100 A TPST with rewirable porcelain
channels in SM sheet enclosure.Each5,400.00PWD SR 10 - 11 Pg No. 32
It.No.1Basic Rate5,400.00Add : AW0.0Sub- Total5,400.0031Fixing of
15 Amps to 63 TPST / change over switch / contactor along with
neutral link with screws, bolts, nuts and wiring using required
capacity wires and circuit lableling.Each165.00PWD SR 10 - 11 Pg
No. 30 It.No.16 (a)Basic Rate165.00Add : AW0.0Sub-
Total165.0032Fixing of 100 Amps to 250 TPST / change over switch /
contactor along with neutral link with screws, bolts, nuts and
wiring using required capacity wires and circuit
lableling.Each500.00PWD SR 10 - 11 Pg No. 30 It.No.16 (b)Basic
Rate500.00Add : AW0.0Sub- Total500.0033Supplying and fixing 20" x
20" x 2.5" polished wood board made of not less than 15 mm thick
plank on bth sides with planks made out of not more than 2 pieces
and fixing the same to the wal using tapered invertred wooden plugs
screws etc.Each285.00PWD SR 10 - 11 Pg No. 32 It.No.2 (f)Basic
Rate285.00Add : AW0.0Sub- Total285.0034Supplying and fixing 12 Way
regular MCCB distribution panel confirm tgo IS 8828, on
wall/woodboard/flush mounting using required clamps, bolts, nuts
etc., with provision for fixing of suitable type capacity MCCB's as
an incomer of 3 phase Double door with necessary busbar completely
wired to use on 440 Volts 3 phase 4 wire powder coated painting
etc., complete with a rpovision for fixing of single / three phase
suitable capacity MCCB/MCB's as outgoings confirm to
IS8825.Each7,640.00PWD SR 10 - 11 Pg No. 36 It.No.11(c)Basic
Rate7,640.00Add : AW0.0Sub- Total7,640.0035Supplying and fixing 32
Amps DP miniature circuit breakers on existing MCB distribution
boards using necessary fixing materials and wiring complete as
requiredEach510.00PWD SR 10 - 11 Pg No. 36 It.No.12(C)(1)Basic
Rate510.00Add : AW0.0Sub- Total510.0036Supplying, fixing and wiring
electronic 10 to 40 Amps three phase 4 wire class - 1 Accuracy
Energy Meter.Each4,120.00PWD SR 10 - 11 Pg No. 39 It.No.26(a)Basic
Rate4,120.00Add : AW0.0Sub- Total4,120.0037Supplying, fixing,
wiring, earth electrode for grounding conduits, IC cutouts and
other equiments on the meter board using 40 mmdia 2.90 hick GI pipe
2.5 mtr long buried in a pit . The pit should be filled with equal
proportion of salt and charcoal 150 mm alround the pipe to complete
the depth. The connection from the pipe to the conduit etc. is to
be established through GI wire of size as per ISI specification
7.3.3 of IS 732 using 12 mm dia bolts, nuts, washers and check nuts
etc., the pipe shall have 16 through holes of 12 mm
dia.No1,950.00PWD EL SR 07-08 Pg No. 68 It.No.1Basic
Rate1,950.00Add : AW0.0Total1,950.0038Supplying and running 8 SWG
GI conductor for grounding and (along with other wires in conduit
system of wiring) using necessary suitable size clamps, nails,
guttas/spacers etc.Per Mtr20.00PWD EL SR 07-08 Pg No. 75
It.No.23(I)( c )Basic Rate20.00Add : AW0.0Total20.0039Supplying of
3.5 core x 25 Sq. mm LT UG cable having aluminium conductor PVC
insulated, sheathed, galvanised, steel wire/steel tap armoured
cable with PVC outer sheathing 1.1 KV classPer Mtr215.00PWD EL SR
07-08 Pg No. 68 It.No.4(I)(e).Basic Rate215.00Add :
AW0.0Total215.0040Labour charges for laying of 3.5 core x 25 Sq.
mm, 1.1 KV/class UG cable when supplied agency in existing trench
GI pipe / stoneware pipe / on wall / on pole as required.R
Mtr11.00PWD EL SR 07-08 Pg No. 69 It.No.5(I)(b).Basic Rate11.00Add
: AW0.0Total11.0041Digging of trench of in Soil (hard), 0.6m deep x
0.50 mtr wide refiling the trench to the required ground level and
consolidating etc., complete. (As per Civil SR KSRB 1-2, P-7)R
Mtr50.00PWD EL SR 07-08 Pg No. 70 It.No.6(b).Basic Rate50.00Add :
AW0.0Total50.00
Rate AnalysisRate Analysis :-Construction of Toilet Block
Building and Dining Hall at Dargah Hazarath Khwaja Banda Nawaz
(Rh), Gulbarga.Sl. NoParticulars of workItem No & Page
NoUnitRate (Rs)1KSRB 2-1.2 : Earthwork in surface excavation in
Ordinary soil for levelling and lowering the ground manually (other
than foundation of buildings, culverts, road drainns and trenches
of pipe line and cables) and removing the excavated ftuff to a
distance not exceeding 50m and lift up to 1.5m, excavated surface
levelled and neatly dressed, disposed earth to be neatly dressed as
per specificaton. Page No-6 Item No 2.2(PW,P & IWTD,Gulbarga
circle Gulbarga Circle 2013-14 P-5 i-2.1)Cum116.002KSRB 2-2.2
Earthwork excavation for foundation of buildings, watersupply ,
sanitary lines & electrical conduits either in pits or in
trenches 1.5 m & above in width, in hard soil not exceeding 1.5
m in depth including dressing the bottom & sides of pits &
trenches, starting the excavated soil clear from edges of
excavation with lead upto 50 m after breaking the clods with all
lead and lift, including cost and conveyance of all materials,
labour, all other incidental charges etc., complete as per
specification and as directed by the Engineer-in-charge of
work.(PW,P & IWTD,Gulbarga circle Gulbarga Circle 2013-14 P-5
i-2.4)Cum209.003KSRB 4-1.3: Providing and laying in position plain
cement concrete of nominal mix M7.5 with OPC cement @ 180 Kg with
40 mm and down size graded granite metal coarse aggregates @ 0.85
cum and fine aggregates @ 0.57 cum machine mixed, concrete laid in
layers not exceeding 15 cms thick well compacted in foundation and
plinth including cost of all materials, labour, HOM of machinery,
curing, complete as per specification(PWP & IWTD DSR, Glb.
2013-14 P.No. 12 I.No. 4.3)Cum3877.004KSRB 4.2.9: Providing and
laying in position reinforced cement concrete of mix M20 with OPC
cement @ 320 Kgs with 20 mm and down size graded graite metal
coarse aggregates @ 0.69 cum and fine aggregates at 0.46 cum,
machine mixed concrete laid in layers not exceeding 15 cms thick
vibrated for RCC beams, columns of all sizes in foundation plinth
and super structure ground floor level for roof slabs, staircase,
lintels, columns including cost of all materials, labour, HOM of
machinery, curing complete as per specification(PWP & IWTD DSR
Glb. 2013.14 P.No. 15 I.No. 4.17)Cum5071.00For First Floor
Additional rate of Rs. 50.00/CumCum5121.005KSRB 2.3 : Filling
available excavated earth (excluding rock) in sides of foundations
upto plinth in layers not exceeding 20 cms. in depth, compacting
each deposited layer by ramming after watering with lead upto 50m.
and lift upto 1.5m. including cost of all labour complete as per
specifications.(PW,P & IWTD,Gulbarga circle Gulbarga. 2013-14
It. No. 2.10, P. No. 6)Cum93.96KSRB 6-2.3 Providing and
constructing burnt brick masonary with approved quality of non
modular bricks of standard size of class designation 50(table
moulded) with cement mortar 1:6 for basement and super structure
including cost of materials.labours charges, scaffolding,curing
complete as per specification No KBS 6.3(PW,P & IWTD,Gulbarga
circle Gulbarga. 2013-14 It. No. 6.6 P. No30)Cum5194.00For First
FloorCum5219.007KSRB 4.9.2 : providing TMT steel reinforcement for
RCC work including straighten, cutting, bending, placing in
position lapping & / or welding wherever required tying
with+B48 binding wire and anchoring to the adjoining members
wherever necessary completed as per design (lapps, hooks &
eastage shall not be measured & paid) cost of materials,
labour, HOM of machinery complete as per specification & lift
charge for steel of all diameters for additional floors over ground
floor per q floor height of 3.5m or part there of cost of labour,
complete as per specifications.No-KBS 4.6.3 (Fe 500)(PWDSR 2013-14
P-16 It no-4.46.2)Qtl6846.008KSRB 4-6.1 : Providing and removing
centering, shuttering, strutting, propping etc., and removal of
form work for foundations, footings, bases of columns for mass
concrete including cost of all materials, abour complete as per
specifications. Specification No. KBSspecification No. KBS
4.6.2(PWD DSR 2013-14 It.No.4.28, P.No.16Sqm197.009KSRB 4-6.5 :
Providing and removing centering, shuttering, strutting, propping
etc., for columns, pillars, piers, abutments, post and struts,
square / rectangular / polygon in plan including cost of all
materials, labour complete as per specifications.(PWD DSR 2013-14
It No.4-32 P No.17)Sqm303.0010For Coloumn First Floor ( Additional
rate Rs. 20 Shall be added for every additional meter or part there
of for the above limits.Sqm403.0011KSRB 4-6.7 : Providing and
removing centering, shuttering, strutting, propping etc., and
removal of form work for sides and soffits of beams, beam
haunchings, cantilever girders, bressumers and lintels not
exceeding 1m in depth including cost of all materials, labour
complete as per specifications. Specification No. KBS 4.6.2PWD
SR.2013-14 It No.4-34 P No 17Sqm219.00For First Floor Roof
BeamSqm319.0012KSRB 4-6.2 : Providing and removing centering,
shuttering, strutting, propping etc., and removal of form work for
flat surface such as suspended floors, roofs. landings, balconies
and likes, thickness upto 200mm including cost of all materials,
labour com Gulbarga circle Gulbarga.PWP&IWTD 2013-14 It No.4.29
, P. No.14Sqm257.00For First FloorSqm800.0013KSRB 6-7.4
:Construction of Partition wall 11.2 cms thick with non modular
table moulded burnt bricks of class designation 50 with cement
mortar 1:4 including cost of materials, labour charges,
scaffolding, curing with all lead and lift, including cost and
conveyance of all materials, labour, all other incidental charges
etc., complete as per specification and as directed by the
Engineer-in-charge of work.(PWD DSR 2013-14 P-33
L-6.26)Sqm697.0014KSRB 7.1 : Providing and fixing in position
collapsible steel shuttures with single or double leaf with
verticle channel 20mmX10mmX2mm braced with flat iron diagonals
20mmX5mm size, with top and bottam rails of T iron sections of
40X40X6mm with 38mmdia steel pulleys complete with bolt and nuts,
locking arrangements, stoppers, handles on both sides with 7.5cms
openings at 10cms. c to c applying a priming coat of red lead
paint. cost of materials, labour, HOM of machinery complete as per
specifications.size of gate 2.4mX 1.40m Specification No. KBS
7.7/7.12Specification No. KBS 7.7/7.12 (PWD DSR 2013-14 It No.7.1 P
No.36)sqm4051.0015KSRB 7.17: Providing, fabricating, assembling and
fixing in position anodized aluminium doors using following
aluminium mat finish or glossy finish, outer frame plain
section101.6x44.45mm thickness 3.18mm, section weight 2.404 kg/m,
door shutters vertical section 44.62x44.45mm thickness 3.18mm,
section weight 1.505klg/m, top section 47.62x44.45mm thickness 3.00
mm, section weight 1.426kg/m bottom section 114.3x44.45 thickness
3.18mm, section weight 2.646kg/m door central section 49.91x44.45mm
thickness 3.00mm, section weight 1.495 kg/m glazing clips
19x17.3x11mm thickness 0.9mm section weight 0.124kg/m; aluminium
sections anodized 12 to 15 microns cut to length joint metred
corners grinded, the shutters pivoted opening arrangement with
heavy duty aluminium alloy automatic door closures floor mounted,
providing and fixing standard approved accessories, such as
aluminium handle for full width or length, tower bolts, lock,
pivots PVC or rubber gasket with 5.5m thick plain glass for top and
bottom panel aluminium sections treated for removal of any rust and
prevetnion of further rust formation, and coated with greasy
materials for non adherence of mortars or any other sticky
materials; the(PWD DSR 07-08 It. No. 7.17, P. No.
41)Sqm5879.007.17Sqm4329assembled frame fitted with the corner
angles, strips and fitted with screws, rawl plugs or teakwood
gutties to R.C.C. columns or masonry on sides beams and flooring in
bottom including cutting, chistling and making good with cement
mortar to match the surface; all the frames throughly cleaned free
from rust, scale, or dirt including cost of materials, fixtures,
labour and HOM of machinery complete as per16Providing Honne wood
frames of doors, windows, clerestory windows ventilators and other
frames, wrought, framed or assembled including making plaster
groves (excluding cost of cement concrete and side clamps), but
including cost of materials, labour,HOM of machineries with all
lead and lift, including cost and conveyance of all materials,
labour, all other incidental charge etc., complete as per
specification and as directed by the engineer-in-charge of
work,(PWDSR 2013-14 P-55 L-9.11)cum81044.0017KSRB 9.5-1 Providing
and fixing in position fully panelled Hone wood shutters for door,
style and rails of 40mm.thick with bottom and rock rails 180mm wide
top rails and styles 100mm wide as per drawing and panels of 25mm
thick including cost of materials, labours, HOM of machineries
complete as per Specification with all lead and lifts and as per
the direction of Engineer-in-charge.Specification No KBS 9.34KSRB
2010-2011 It No 9.15 P No.56Sqm3707.0018KSRB 7.12 : Providing and
fixing in position anodized aluminum windows and ventilators as per
approved drawings with sliding shutters using four track window
framwe of size 122.2X31.75mm.for bottom section 1.1mm thick, weight
1.205kg/m: sides and top sections 1.2mm. thick weight 1.093 kg/m:
shutter section comprising top and bottom section of size 40mm X
18mm wall thickness 1.25mm. weight 0.417kg/m, shutter side outeer
40mmX 18mm wall thickness 1.25mm weight 0.417kg/m, shutter inerlock
sections 40mm X26.7mm wall thickness 1.1mm weight 0.469 kg/m,
shutters mouunted on nylonrollers with approved quality of fixtures
suck as aluminuun handles, tower boolts etc, providing and fixing
5.5mm. thick plain glass for shutters fitted with rubber beading
aluminium sections anodised 12 to 15 microns, including cutting to
requried length , joint mitred subdividing the frame. tenonned and
rivetted in the assembled frame to be frame to be stiffened with
end clips at cormers,angle etc, fixed to the walls intels, floor
beams, cills, as the case may be with necessary steel screw s, raul
plugs, or teak wood gatties including cutting masonary or concrete
and making good the original surface using cement mortar: aluminium
sections pretreated of removal of any rust and coated with greasy
materials for non adhesion of mortar and other sticky
materials,(this coating should be cleaned after installation)
including cost of materials, foxtures, labour and HOM of machinery
complete as per specification. ( PWP& IWTD 2013-14, P.No 39.
It,No.7.12Sqm326119KSRB 7.9 : Providing and fixing M.S. grill work
of windows and ventilators weighing 21 kg/sqm using M.S flats, or
M.S. square rods, or combination of M.S. flats and square rods as
per approved design, drawing including cutting steel sections and
welding the same to required pattern with a coat of red lead
primer, cost of materials, fixtures, labour and HOM of machinery
complete as per specifications. Specification No. KBS 7.12 (PWD DSR
2013-14 It. No. 7.9, P. No. 37)Kgs89.4920KSRB 15-3.10 :Providing
20mm thick cement plaster in single coat with cement mortar 1:4, to
stone masonry and concrete surrface including rounding off corners
wherever required smooth rendering, :Providing and removing
scaffolding, including cost of materials, labour, curing complete
as per specifications.(PWD DSR 2013-14 It. No. 15.19, P. No.
123)Sqm174.0021KSRB 15-3.10 :Providing 20mm thick cement plaster in
single coat with cement mortar 1:3, to stone masonry and concrete
surrface including rounding off corners wherever required smooth
rendering, :Providing and removing scaffolding, including cost of
materials, labour, curing complete as per specifications