BXB ELECTRONICS CO., LTD. 1 W W M M P P - - 1 1 2 2 0 0 6 6 Speaker Circuit Zone Selector User Manual V Ve e r r s s i i o o n n : : 1 1 . . 0 0 D D a a t t e e : : F F e e b b r r u u a a r r y y 2 2 0 0 , , 2 2 0 0 1 1 3 3
BXB ELECTRONICS CO., LTD.
1
WWMMPP--11220066 SSppeeaakkeerr CCiirrccuuiitt ZZoonnee SSeelleeccttoorr
UUsseerr MMaannuuaall
VVVeeerrrsssiiiooonnn::: 111...000
DDDaaattteee::: FFFeeebbbrrruuuaaarrryyy 222000,,, 222000111333
BXB ELECTRONICS CO., LTD.
2
Contents ................................................................................................................................................ 2
Overview ............................................................................................................................................... 3
System Features ................................................................................................................................... 4
Safety Instructions ............................................................................................................................... 5
Operation and Features........................................................................................................................ 6
Front Panel Description ....................................................................................................................... 6
Rear Panel Description ........................................................................................................................ 7
Connection ............................................................................................................................................ 8
Contents
BXB ELECTRONICS CO., LTD.
3
Thank you for purchasing WMP-1206 Speaker Circuit Zone Selector from BXB Electronics Co.
WMP-1206 is the latest speaker circuit zone selector with superb performance and elegant design
which can be used in various occasions.
The advanced digital control module provides 6 in 12 out single-area broadcast buttons, 1
programmable group button and 1 all-call button to make your PA system even more powerful.
Built-in RS-485, RS-232 and USB ports facilitate integrating with other control systems.
High reliability is our utmost purpose when developing BXB system. Each main control unit and its
fittings have all gone through careful assembly and strict test in our ISO 9001 approved factory. The
excellent performance, high reliability and reasonable price make it the indispensable system for you.
Overview
BXB ELECTRONICS CO., LTD.
4
1. 12 single-zone buttons, loads more than 300W
2. 1 programmable group button
3. 1 all-call button
4. LED display on each button
5. Group button setting can be changed anytime
6. Zone activate by relay connection
7. Crosstalk prevents design
8. RS-485, RS-232 and USB ports facilitate integrating with other control systems
9. Input control flip-flops for remote activate timer-clock
10. Output control flip-flops for remote activate amplifier
11. WMP-1206 can be used individually or used with digital/ analog connect. With RS-485 port, it can
expand another WMP-1206; expand apparatuses are unlimited when using analog contacts.
12. Up to 6 speaker circuit inputs and 12 speaker circuit outputs for random combination.
13. Multiple units connectable for area expansion.
【Specification】
◎ Power Supply: DC15V/1A (MAX)
◎ Output: 12 zones, 300W for each zone, maximum 3600W in total
◎ 12 single-zone switches, 1 group switch and 1 all-zone switch
◎ 1 remote all-call input terminal
◎ All the switches are equipped with indicators.
◎ W 483 x H 89 x D 270 (mm)
System Features
BXB ELECTRONICS CO., LTD.
5
Safety Instructions
1. Please read and observe these instructions before installing and using the apparatus.
2. Use only accessories specified by the manufacturer. The manufacturer is not liable for damage
caused by the use of non-specified accessories.
3. Install the apparatus and its accessories carefully. Strike and fierce shaking may damage the
apparatus.
4. Make sure the power cord is fixed properly.
5. Do not overload wall outlets and extension cords as this can result in a risk of fire or short circuit.
6. To reduce the risk of damage from lightning strikes, it is important that all electric cables should
be bonded to the same grounding point.
7. Do not block any ventilation openings to prevent overheating and malfunction.
8. Do not expose the apparatus to rain or moisture.
Humidity may lead inside components to damage. Appropriate shelter is necessary when placing
it outside (Best working environment: Temperature 0°C ~ 40°C , humidity below
90%).
9. Please do not switch on and off the apparatus rapidly.
Rapid switch on and off the apparatus should be avoided all the time to prevent inside sensitive
electronic circuits from being damaged by surges.
10. Do not clean the apparatus and its accessories with chemical solvents. Use only a clean,
dry/dampish cloth.
11. Refer to maintenance technician when the apparatus has been damaged in any way, such as:
A• power-supply cord or plug is damaged
B• liquid has been spilled in
C• has been exposed to rain or moisture
D• has been dropped
E• objects have fallen into the apparatus
F• does not operate normally
12. Note: When the printed circuit board is going through electric static treatment, correct ESD
safety precaution and grounding should be assured.
13. Note: Before connecting the apparatus to main AC, please select the supply voltage in
accordance with the wall voltage in your country to prevent damage. Refer to Installation and
Setting (Page 8) for selecting.
14. Warning: Do not disassemble or remodel the product, as these actions may lead to electrical
shock or damage. The guarantee on the product will become null if the product is ever
disassembled.
BXB ELECTRONICS CO., LTD.
6
Front Panel Description
○1 1-12 single-zone broadcast buttons
○2 1-12 single-zone LED indicators
○3 Programmable group button
Simply press the group button and you can broadcast to preset groups.
Preset groups:
Press the single zones that you want to added in the group button (LED is on), and then press
the group button for three seconds, flashing LED means setting is saved.
Repeat instructions above to change setting. Reprogram the memory is not essential.
○4 Group broadcast LED indicator
○5 All-zone broadcast LED indicator
Operation and Features
BXB ELECTRONICS CO., LTD.
7
Rear Panel Description
USB
RS-485
RS-232
DC 15V/2AID
OUTPUT
INPUT
100V COM
BGM
○1 BGM background music amplifier (COM/100V) input terminal
○2 1-6 groups of speaker circuit input terminal (1 input corresponds to 2 outputs)
○3 RS-485 communication port for other controller expansion
○4 USB 2.0: USB port (connects to PC for BXB graphical control software)
○5 RS-232 communication port for other control systems
2nd foot: Transmitted Data (Tx)
3rd foot: Received Data (Rx)
5th foot: Signal Ground (G)
○6 1-12 groups of speaker circuit output terminal (2 outputs correspond to1 input)
○7 ID: DIP switch identity code (for expanders)
○8 External dry contact: all zone broadcast activates when contacted.
○9 Dry contact: contacted when WMP-1206 is activated (to activate amplifier).
○10 WMP-1206 working voltage: DC12V ~ DC15V (MAX)
BXB ELECTRONICS CO., LTD.
8
Connection
Sound amplifies to 100V high voltage through power amplifiers, and transmits to WMP1206. Last, it is
outputted to speakers that broadcaster prefer. Dry contacts are triggered when the zone is activated,
they would turn on power amplifiers.
CD Player
LEVEL
POWER
PL
AC0FF
ON
AUTO FUSE AUTO FUSE
DC
Amplifier
BXB graphical managing controller
USB PORT
Microphone
STANDBY/ON
STANDBYOPEN/CLOSE
01INDEX
EDIT
01TRACK MIN
00:00
SEC
DISPLAY OFFTIME
disc..AUTO
EDITHI-LITE
CD-DECK SYNCHIROPROGRAM
.COMPU
RANDOM REPEAT
1 2 3 4 5 6
87 9 10 11 12
ALL Call
Dry Contact Output
POWER
WMP-1206
AMX-1001 Mixer
Dry Contact Input
Ceiling-mounted or Wall Speaker
Audio Signal
LEVEL
POWER
PL
AC0FF
ON
AUTO FUSE AUTO FUSE
DC
Amplifier
1 2 3 4 5 6
87 9 10 11 12
ALL Call
LEVEL
POWER
PL
AC0FF
ON
AUTO FUSE AUTO FUSE
DC
Amplifier
High
1 2 3 4 5 6
87 9 10 11 12
ALL Call
Up to 4 units, 48 zones
Zone 1
Ceiling-mounted or Wall Speaker
Zone 2
Other application control system
RS-232 PORT
Ceiling-mounted or Wall Speaker
Zone 11
Ceiling-mounted or Wall Speaker
Zone 12
Ceiling-mounted or Wall Speaker
Zone 3
Ceiling-mounted or Wall Speaker
Zone 4
Ceiling-mounted or Wall Speaker
Zone 5
Ceiling-mounted or Wall Speaker
Zone 6
OUTPUT1,2
OUTPUT3,4
OUTPUT5,6
OUTPUT11,12
WMP-1206
WMP-1206
RS-485PORT
CD Player
Microphone
STANDBY/ON
STANDBYOPEN/CLOSE
01INDEX
EDIT
01TRACK MIN
00:00
SEC
DISPLAY OFFTIME
disc..AUTO
EDITHI-LITE
CD-DECK SYNCHIROPROGRAM
.COMPU
RANDOM REPEAT
POWER
AMX-1001 Mixer
CD Player
Microphone
STANDBY/ON
STANDBYOPEN/CLOSE
01INDEX
EDIT
01TRACK MIN
00:00
SEC
DISPLAY OFFTIME
disc..AUTO
EDITHI-LITE
CD-DECK SYNCHIROPROGRAM
.COMPU
RANDOM REPEAT
POWER
AMX-1001 Mixer
CD Player
Microphone
STANDBY/ON
STANDBYOPEN/CLOSE
01INDEX
EDIT
01TRACK MIN
00:00SEC
DISPLAY OFFTIME
disc..AUTO
EDITHI-LITE
CD-DECK SYNCHIROPROGRAM
.COMPU
RANDOM REPEAT
POWER
AMX-1001 Mixer
Audio Signal
Audio Signal
Audio Signal LEVEL
POWER
PL
AC0FF
ONAUTO FUSE AUTO FUSE
DC
Amplifier
INPUT1
INPUT2
INPUT3
INPUT6
VoltageSignal
100V/COM
HighVoltageSignal
100V/COM
HighVoltageSignal
100V/COM
HighVoltageSignal
100V/COM
High Voltage Signal(Max 300W for each zone)
1 2 3 4 5 6
87 9 10 11 12
ALL Call
WMP-1206
RS-485PORT
RS-485PORT
BXB Electronics Co., LTD. TAIWAN | Website: www.bxb.tw
PA System / Conference System / Language Laboratory System
TEL:+886(7)970-3838 FAX:+886(7)970-3883
http://www.bxb.tw/