Top Banner

of 32

BW Industries Steel Framing Systems 2014

Mar 10, 2016

Download

Documents

BW Industries

BW Industries or indeed a returning user then we would advise you that we are a competitive alternative for steel components and particularly for our range of Steel Framing of both Load Bearing and Non-Load Bearing sections.
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
  • Steel Framing Systems

    making steelmaking steelwork

    INDUSTRIES

    TECHNOLOGY

  • Fire Restraint Wall System Contents

    Introduction............................................................................................ 3

    Design and Certification ........................................................... 4

    BW Steel Framing Systems General Overview ............................................................................ 6

    BW Steel Framing Systems Key Facts and Benefits.............................................................. 7

    SureBUILD Framing System

    SureBUILD Framing System Overview...................... 8

    SureBUILD Framing System Key Facts and Benefits.............................................................. 9

    SureBUILD Framing Design to Delivery ............... 10

    SureBUILD Framing (F) Sections ................................ 12

    SureBUILD Framing (F) Section Properties ...... 13

    SureBUILD Connecting and Fixing Details ....... 14

    SFS Framing System

    SFS Framing System Overview.................................... 18

    SFS Framing System Key Facts and Benefits 19

    SFS Infill, Continuous and High Bay Separating Walls .......................................................................... 20

    SFS Stud (S) Sections............................................................ 22

    SFS Stud (S) Section Properties.................................. 23

    SFS Track (T) Sections........................................................... 24

    SFS Track (T) Section Properties ................................ 25

    Partition and Dry Lining Sections

    Partition and Dry Lining Sections Overview..... 26

    Partition and Dry Lining Sections Key Facts and Benefits ......................................................... 27

    Partition Walls and Dry Lining ........................................ 28

    Partition and Dry Lining (P) Sections....................... 29SureBUILD is a registered Trademark of BW Industries Ltd.

    About technologyThe material is steel, the technology is SureBUILD.Lightweight, load bearing framework for all applications industrial, commercial, modular and domestic. The SureBUILD name reflects the ongoing productdevelopment, independent testing and analysis, manufacturingspeed and accuracy, and overall cost effectiveness.

    SureBUILD solutions in steel

    TECHNOLOGY

    2BW Framing TEL 01262 400088 EMAIL [email protected] WEB www.bw-industries.co.uk

  • 3 BW FramingTEL 01262 400088 EMAIL [email protected] WEB www.bw-industries.co.uk

    Fire Restraint Wall System Introduction

    The CompanyBW Industries is a privately ownedcompany providing steelcomponents for the construction,manufacturing and agriculturalsectors from our 13175mproduction facility.

    BW Industries are also suppliers tothe domestic market and export toother countries worldwide.

    As a reflection of our clearcommitment we have gained aleading position in the steelsections industry by our insistencewithout compromise, that allcomponents are of high quality andare accurately manufactured whilstremaining cost effective.

    Since its establishment in 1974, BW Industries are proud to have an excellent reputation in theconstruction and manufacturingsectors, established throughcontinued commitment and anunrivalled service level.

    QualityBW Industries has a QualityAssurance System which isaccredited to BS EN ISO 9001-2008 and that covers all aspects ofour operations, and is CE approved.

    Our excellent personal servicebacked up by commitment toquality ensures that BW Industriesachieve the highest levels ofcustomer satisfaction.

    SustainabilityBW Industries are committed tosupporting and developingsustainability throughout all itsdepartments.

    Steel is one of the most recycledmaterials used in the world. Use ofrecycled material does notcompromise the quality of new steelproduced by it.

    By addressing key issues such asproduct design, CO emissions,recycling of waste materials andprudent use of all resources, BWIndustries take responsibility formanaging environmental issues.

    ProductsThe wide range of productssupplied by BW Industries may be split into the following areas:-

    Purlins, Sheeting Rails and Eaves Beams

    Mezzanine Floor Beams (primary and secondary)

    SureBUILD Framing

    SFS Framing

    Partition and Dry Lining Sections

    Offsite Modular Buildings

    Cold Formed Portal FramedBuildings

    Press Formed Sections

    Grainwalling

    Laser Cut Components

    This brochure relates specicallyto SureBUILD Framing, SFSFraming and Partition and DryLining Sections.

  • 4BW Framing TEL 01262 400088 EMAIL [email protected] WEB www.bw-industries.co.uk

    DesignAll of BW Industries steel section property informationand load tables have been independently assessedand verified under the SCI Assessed SchemeCalculation of the member resistances. The sectionproperties are calculated in accordance with BS-EN1993-1-3 (Design of steel structures. Part 1-3 Generalrules Supplementary rules for cold-formedmembers and sheeting BSI 2006).

    They are provided as an aid to designers andspecifiers to allow selection of the optimum section.

    ManufactureThe information on any fabrication drawings anddetails is programmed into a Cam data file which istransmitted directly to the rolling or fabrication plant.

    All major components are normally ink jet printed toshow what they are and from which material theyhave been formed.

    This process is so that there is a trail which showsexactly what has been manufactured.

    Dispatch and SupplyBW Industries have a team of experienced personnelwho hand pick the items for dispatch and load theseonto the vehicles which have been arranged foronward transportation. Depending on the end usersrequirements, specialist vehicles with on board liftingequipment can be arranged to facilitate material off-loading at the delivery address.

    CE MarkingBW Industries Limited Factory Production Controlwas third part assessed against EN 1090-1:2009+A12011, by SGS UK. We achieved accreditation toEXC2 and standard ISO 14731 and ISO 3834.

    This certification covers the following products:Steel Structural Purlins, Mezzanine Steel Channels,Fabricated Structural Steel Assemblies andSureBUILD Engineered Wall Panels.

    Certification

    BW Industries have developed steel sectionproperty information and load tables basedon the methodology in the relevant Europeanstandards.

    All technical information has been developedby a chartered structural engineer and hasbeen independently checked and verified bythe SCI.

    BW Industries are pleased to display the SCIlogo and to confirm that their products haveachieved SCI Assessed status with theappropriate certification.

    We are also a proud member of the LightSteel Framing Group.

    Photograph of SureBUILD Stud Section undergoing testing at Sheffield University.

    Fire Restraint Wall System Design and Certication

  • 5 BW FramingTEL 01262 400088 EMAIL [email protected] WEB www.bw-industries.co.uk

    Stables manufactured completely from cold rolled steel

    Joists attached to SureBUILD Framing Panels

    Assembled SureBUILD Framing PanelHigh Bay Separating Wall

    SFS Stud and Track

  • BW Steel Framing SystemsOverview

    6BW Framing TEL 01262 400088 EMAIL [email protected] WEB www.bw-industries.co.uk

    The market for steel framing isquickly expanding throughout thedomestic, educational, commercialand industrial sectors. With itsmany benefits including speed ofconstruction and erection, highstrength and long life, it is fastbecoming an economic andversatile alternative.

    BW Industries have invested heavilyin the development of our framingsystems to ensure that we are atthe forefront of technology. Withexpert design and product qualityour cold formed light gauge steelframing is already widely used inthe building industry for manyapplications. Our innovativetechnology and manufacturingmethods are backed up by adedicated and highly experiencedteam, who strive to constantlyimprove and maintain the highservice level and productexcellence.

    We offer three framing systems,SureBUILD Framing, SFS Framingand Partition and Dry LiningSections, all of which offer flexibility,high performance, accuracy andprecision, and weight reductioncompared to other traditionalbuilding methods. We can deliverthe steel to site pre-punched andcut to length ready for installation.

    The BW Industries SureBUILDFraming System is a sophisticatedpre-panelised system that is rivetedtogether within our factory, anddelivered to site in fully formedpanels ready for installation. It isloadbearing and offers a fast andefficient alternative to moretraditional methods of construction.

    The BW Industries SFS Framing isused for continuous, infill and highbay separating walls. We have arange of standard stud and tracksections that are suitable for theseapplications.

    The BW Industries Partition and DryLining Sections are used for drylining and partitions to create nonload bearing internal walls inresidential, industrial andcommercial structures.

    We can also manufacture bespokesection sizes with our vast range ofmachinery, which is capable ofrolling stud and track sections from50mm to 500mm deep with a rangeof gauges from 0.5mm to 5mm.

    All of the sections used in the BWIndustries Framing Systems arequality assured to Euro Codes andrigorous internal quality procedures,ensuring the highest quality timeafter time and we continue todevelop and enhance ourcomprehensive range of highquality products and services.

  • BW Steel Framing SystemsKey Facts and Benets

    7 BW FramingTEL 01262 400088 EMAIL [email protected] WEB www.bw-industries.co.uk

    Structural Framing Systems to suit all applications (loadbearing and non-loadbearing)

    SureBUILD Framing can be delivered to site pre-panelised

    Wide range of sizes available from 50mm to 500mm webs with a range of gauges from 0.5mm to 5mm

    Delivered to site pre-punched and cut to length ready for installation

    Speed of erection and completion on site

    Increased stability and durability

    Galvanised steel for tough, continuous long life protection

    Quality assured products with reliable performance

    Consistency, accuracy and precision time after time

    BW section properties are calculated in accordance with BS-EN 1993-1-3

    Quality assured to Eurocodes

    Rigorous internal procedures ensures quality

    All of the steelwork is 100% recyclable and all steel is currently manufactured using 40% recycled steel

  • BW Industries have installed a SureBUILD Framingrolling mill, housed in by a purpose built factory, toproduce a range of steel framing that can besupplied in either stick form or fully assembledpanels. The assembled panels are fitted togetherusing a sophisticated Rivet System, which is bothtime and cost effective.

    The SureBUILD light gauge steel framing is asophisticated load bearing wall framing system thatoffers fast erection and completion and alsoincreased stability and durability. It is ideal for off-site construction, house building and multi-storey applications. Fully load-bearing andnon-load bearing options are available, and we canprovide in-house design and drawing facilities.Complete with fully-integrated 3D CAD/CAM designsoftware by Vertex Systems and combined with theproduction facilities and the experience of BWIndustries, this product offers performance,predictability and design flexibility.

    Vertex Building Design (BD) is an advanced BuildingInformation Modelling (BIM) software package forcold-rolled steel framed construction. Utilising BIMtechnology, this stand-alone software maximisesproductivity and accuracy by generating wall paneldrawings, material reports and manufacturing dataall from one source. To save on design time, wallframing drawings are automatically produced, withevery component having a unique identificationnumber. Once the design is complete,manufacturing data is transferred directly from theVertexBD software to the BW Industries SureBUILDrolling line where each part is rolled and printed withits unique number.

    The components produced offer a flush finish panel,and the sections can be pre-punched to offerservice slots or holes to suit your individualapplication.

    8BW Framing TEL 01262 400088 EMAIL [email protected] WEB www.bw-industries.co.uk

    SureBUILD Framing SystemOverview

  • 9 BW FramingTEL 01262 400088 EMAIL [email protected] WEB www.bw-industries.co.uk

    BW Industries SureBUILD sections are supplied intwo standard widths of 75mm and 100mm

    Gauges for the 75mm section comprise 1.0, 1.2and 1.5mm

    Gauges for the 100mm section comprise 1.2, 1.5and 2.0mm *2mm from a lesser yield

    Used for load bearing applications

    Full stand-alone structural system

    Eliminates the need for hot rolled steel or aconcrete primary frame

    Swaging of the vertical studs allows for a flushfinish wall profile which facilitates fixing ofboarding or linings.

    The bottom corners of the studs are trimmedprior to folding the section to allow the stud to sitdirectly onto the face of the bottom track thusgiving direct transfer of vertical load rather thanthrough the fixings

    Window and door openings are easilyaccommodated

    Bracing formed from the stud section can beincorporated within the wall structure, which isstrong both in tension and compression thereforeeliminating the need for external cross bracing.

    BW Industries have the ability and capacity tosupply SureBUILD in either stick form or fullyassembled panels

    The steel gauges are core steel thickness plus thestandard (Z275) zinc coating thickness of0.04mm.

    Sections are generally manufactured from thegrade S450 steel with a minimum yield strength of450N/mm (2mm from lesser yield)

    SureBUILD Framing offers increased stability anddurability

    SureBUILD Framing SystemKey Facts and Benets

  • 12

    3 6 8 1010 1212 1414 1616 21211818

    4

    5

    7 9 1111 1313 1515 1717

    1919

    2020

    46204620

    2510

    2510

    476

    476

    1079

    1079

    1682

    1682

    2285

    2285

    2888

    2888

    3491

    3491

    4094

    4094

    B1B1 B1B1

    10BW Framing TEL 01262 400088 EMAIL [email protected] WEB www.bw-industries.co.uk

    SureBUILD Framing System

    Design to Delivery

    Typical Panel Drawing

    Vertex model designedby BW Industries

    3D Wall Panel image

  • Erected Steel Structure manufactured entirely from cold rolled steel

    Items loaded by dedicated team of experienced personnelAssembled panels awaiting delivery

    Framing panel riveted together in purpose made jigStud section rolled on the SureBUILD Framing line

    11 BW FramingTEL 01262 400088 EMAIL [email protected] WEB www.bw-industries.co.uk

    SureBUILD Framing System

  • 12BW Framing TEL 01262 400088 EMAIL [email protected] WEB www.bw-industries.co.uk

    SureBUILD Framing (F) Sections

    Range Depth Flange Lipmm mm mm

    F75 75 42 8

    F100 100 50 12.5

    Range Gauges mm

    F75 1.0, 1.2, 1.5

    F100 1.2, 1.5, 2.0

    Track sections are the same strip as above but with no lips

    Range Depth Flangemm mm

    F75 75 50

    F100 100 62.5

    Range Gauges mm

    F75 1.0, 1.2, 1.5

    F100 1.2, 1.5, 2.0

    These sections are generallyordered in panel format and supplied either fully

    assembled or in stick form

    *2mm from a lesser yield

    *2mm from a lesser yield

    SectionReference

    Weightkg/m

    Second Moment of Area

    Major Axiscm4

    Minor Axiscm4

    Major Axiscm3

    Minor Axiscm3

    Major Axiscm

    Minor Axiscm

    Major AxiskNm

    Section Modulus Radius of Gyration MomentCapacity

    F7510 1.31 14.99 3.72 4.00 1.32 3.05 1.52 1.69

    F7512 1.56 17.77 4.38 4.74 1.56 3.04 1.51 2.27

    F7515 1.92 21.72 5.31 5.79 1.89 3.01 1.49 3.11

    F10012 2.03 40.62 8.62 8.12 2.59 4.03 1.85 3.47

    F10015 2.51 50.00 10.53 10.00 3.16 4.00 1.84 4.95

    F10020 3.28 64.66 13.44 4.04 34.53 3.96 1.81 7.27

  • 13 BW FramingTEL 01262 400088 EMAIL [email protected] WEB www.bw-industries.co.uk

    F7510 1.24 0.87 0.63 0.37 0.23

    F7512 1.48 1.04 0.76 0.44 0.28

    F7515 1.83 1.29 0.94 0.54 0.34

    F10012 3.00 2.35 1.71 0.99 0.62

    F10015 3.00 2.92 2.13 1.23 0.78

    F10020 3.00 3.00 2.80 1.62 1.02

    Maximum Unfactored Horizontal Wind load for Studs at 600mm centresand full lateral bracing at mid-height, value limited to 3.0kN/m2

    Maximum Unfactored Axial Load for Studs withfull lateral bracing at mid-height

    Deflection Limit Span/240

    SectionReference

    Wall Height metres

    2.4 2.7 3.0 3.6 4.2

    F7510 0.83 0.58 0.42 0.24 0.15

    F7512 0.99 0.69 0.51 0.29 0.18

    F7515 1.22 0.86 0.63 0.36 0.23

    F10012 2.23 1.57 1.14 0.66 0.42

    F10015 2.77 1.95 1.42 0.82 0.52

    F10020 3.00 2.56 1.87 1.08 0.68

    Deflection Limit Span/360

    SectionReference

    Wall Height metres

    2.4 2.7 3.0 3.6 4.2

    F7510 0.50 0.35 0.25 0.15 0.09

    F7512 0.59 0.42 0.30 0.18 0.11

    F7515 0.73 0.52 0.38 0.22 0.14

    F10012 1.34 0.94 0.68 0.40 0.25

    F10015 1.66 1.17 0.85 0.49 0.31

    F10020 2.19 1.54 1.12 0.65 0.41

    Deflection Limit Span/600

    SectionReference

    Wall Height metres

    2.4 2.7 3.0 3.6 4.2

    F7510 16.10 13.45 11.29 8.19 6.23

    F7512 20.20 16.73 13.98 10.09 7.68

    F7515 26.21 21.54 17.96 12.99 9.91

    F10012 30.06 29.62 27.02 20.74 16.00

    F10015 46.20 41.62 36.06 27.00 20.73

    F10020 68.28 58.71 50.23 37.16 28.44

    Unfactored Axial Load, kN

    SectionReference

    Wall Height metres

    2.4 2.7 3.0 3.6 4.2

    SureBUILD Framing (F) Section Properties

    Panel Load Tables

  • 14BW Framing TEL 01262 400088 EMAIL [email protected] WEB www.bw-industries.co.uk

    SureBUILD Connection and Fixing Details

    Typical wall panel isometric

    Site Fit use 5.5mm wafer head tek screws (2 no. min. both sides)BW Factory Fit self piercing rivets 2 no. min. both sides)

    Bolt down using 6.3mm Tapcon Anchor 600mm CTS Maxbetween wall studs 40mm min embedment depth

    600mmcentres

    150

    50

    6.3mmTapconanchor

    Noggin / stud connection

    Stud / track connection (Swaged for flush finish)

    Typical wall panel bolting down details

    Fixing details shown as a guide only. Use 5.5mm wafer headself-drilling Tek screws

    Typical WallPanel FixingDetails

    150

    150

    50

    50

    50

    4 No. Fixings

    50

    4 No. Fixings

    2 No. Fixings

  • 15 BW FramingTEL 01262 400088 EMAIL [email protected] WEB www.bw-industries.co.uk

    Floor Joists

    SureBUILD Connection and Fixing Details

    Floor Joists and fixing details

    Cleat - Fixed with 6 x Wafer Head Light Duty Self drilling TekScrews. Fixing locations for illustrative purposes only.

    M125 125 52 17 1.3, 1.4, 1.5, 1.6, 1.8, 2.0

    M150 150 50 17 1.3, 1.4, 1.5, 1.6, 1.8, 2.0

    M175 175 64 17 1.3, 1.4, 1.5, 1.6, 1.8, 2.0, 2.3, 2.5

    M200 200 66 17 1.4, 1.5, 1.6, 1.8, 2.0. 2.3, 2.5

    M225 225 78 17 1.5, 1.6, 1.8, 2.0. 2.3, 2.5

    M250 250 85 17 1.6, 1.8, 2.0. 2.3, 2.5, 2.9

    Floor Joist Range

    Section Web Flange Lip Gauge

  • 16BW Framing TEL 01262 400088 EMAIL [email protected] WEB www.bw-industries.co.uk

    SureBUILD Connection and Fixing Detailscontinued

    Site Fit use 5.5mm wafer head self drilling Tek screws 600mm cts between studs

    Z129/75/15 125 129 75 100 1.5

    Z154/75/15 150 154 75 100 1.5

    Z179/75/15 175 179 75 100 1.5

    Z204/75/15 200 204 75 100 1.5

    Z229/75/15 225 229 75 100 1.5

    Z254/75/15 250 254 75 100 1.5

    Z Hanger Section (to suit 75mm Wall Panel)

    Section To Suit Web Top Bottom GaugeJoist Depth Flange Flange

    Z Hanger Section (to suit 100mm Wall Panel)

    Section To Suit Web Top Bottom GaugeJoist Depth Flange Flange

    Zed Hanger fixing details

    Z129/100/15 125 129 100 100 1.5

    Z154/100/15 150 154 100 100 1.5

    Z179/100/15 175 179 100 100 1.5

    Z204/100/15 200 204 100 100 1.5

    Z229/100/15 225 229 100 100 1.5

    Z254/100/15 250 254 100 100 1.5

    Zed Hanger Section

    Top Flange

    Bottom Flange

    Web

  • 17 BW FramingTEL 01262 400088 EMAIL [email protected] WEB www.bw-industries.co.uk

    SureBUILD Connection and Fixing Detailscontinued

    Bracing

    Bracing to give lateralstability to the framescan be provided ifrequired. For theSureBUILD system thiscan be in the form ofintegral K bracingformed within the panelthickness or alternativelycrossed flat bracing fixedto one or both sides ofpanel as required.

    125 129 80 100 1.5

    150 154 80 100 1.5

    175 179 80 100 1.5

    200 204 80 100 1.5

    225 229 80 100 1.5

    250 254 80 100 1.5

    Top Hat Section (to suit 75mm Framing Section)

    To Suit Joist Depth D F1 F2 T

    125 129 105 100 1.5

    150 154 105 100 1.5

    175 179 105 100 1.5

    200 204 105 100 1.5

    225 229 105 100 1.5

    250 254 105 100 1.5

    Top Hat Section (to suit 100mm Framing Section)

    To Suit Joist Depth D F1 F2 T

    Top Hat SectionNote Top Hat section will be used in lieu of Zed where required

    'F1'

    'F2'

    'D' 'T'

    'F2'

  • 18BW Framing TEL 01262 400088 EMAIL [email protected] WEB www.bw-industries.co.uk

    BW Industries SFS range is used forinfill panels, continuous walling andhigh separating walls.

    We supply our cold formedgalvanised SFS sections in stickform for assembly on site, andmanufacture the components cut tolength to suit individualapplications. They can be suppliedin either plain lengths or pre-punched for services etc.

    BW Industries SFS framing offersmany advantages over traditionalmethods of construction such asspeed of erection and completionon site, increased stability anddurability and reduction of weight.

    Our sections are robust andsufficiently light for site handlingand they dont suffer from shrinkageor settlement in comparison totimber and masonry.

    The benefits are both time and costeffective, making our SFS framing apopular option to many.

    With a dedicated andknowledgeable team ofexperienced personal, BW providean excellent and unrivalled servicefrom the point of initial contact rightthrough to delivery of the steel onsite.

    SFS Framing SystemOverview

  • SFS Framing SystemKey Facts and Benets

    19 BW FramingTEL 01262 400088 EMAIL [email protected] WEB www.bw-industries.co.uk

    BW Industries standard SFS sections range in depth from 75mm to 350mm with a range of gauges from 1mm to 3mm

    A range of larger sections up to depths of 500mm and gauges up to 5mm are also available (these can be arranged back to back in pairs to form main structural columns)

    Sections are perfectly straight and are easily adapted on site

    Freedom from shrinkage and settlement

    Weight reduction in comparison to masonry and concrete methods

    Safer and easier site installations

    Resistance against fire, insects and rot

    More time and cost effective to traditional methods of construction

    Increased stability and durability

    Sections are light gauge cold-formed pre-galvanised steel sheet with a Z275 coating

    The stated gauges are core steel thickness plus the standard (Z275) zinc coating thickness of 0.04mm

    Sections are generally manufactured from grade S450 steel with a minimum yield strength of 450M/mm

  • SFS Framing System

    20BW Framing TEL 01262 400088 EMAIL [email protected] WEB www.bw-industries.co.uk

    Infill Walling

    Continuous Walling

    Constructed outside the main frame to maximise the floorarea (requires vertical support for external cladding)

    High Bay Separating WallHigh performancedivision walls thatnormally do notrequire strengtheningof existing floor slabsand can be supplied infull lengths forminimum site work

    A secondary structure (fixed between primarystructures) to infill the external wall and enable thefixing of insulation and external cladding

  • 21 BW FramingTEL 01262 400088 EMAIL [email protected] WEB www.bw-industries.co.uk

  • 22BW Framing TEL 01262 400088 EMAIL [email protected] WEB www.bw-industries.co.uk

    SFS Stud (S) Sections

    Range Depth Flange Lipmm mm mm

    S75 75 42 8

    S100 100 50 12.5

    S125 125 52 17

    S150 150 50 17

    S175 175 64 17

    S200 200 66 17

    S225 225 78 17

    S250 250 85 17

    S300 300 90 19

    S350 350 95 21

    Range Gauges mm

    S75 1.0, 1.2, 1.5

    S100 1.2, 1.5, 2.0

    S125 1.3, 1.4, 1.5, 1.6, 1.8, 2.0

    S150 1.3, 1.4, 1.5, 1.6, 1.8, 2.0

    S175 1.3, 1.4, 1.5, 1.6, 1.8, 2.0, 2.3, 2.5

    S200 1.2, 1.4, 1.5, 1.6, 1.8, 2.0, 2.3, 2.5

    S225 1.5, 1.6, 1.8, 2.0, 2.3, 2.5

    S250 1.2, 1.6, 1.8, 2.0, 2.3, 2.5, 2.9

    S300 2.0, 2.3, 2.5, 2.9

    S350 2.3, 2.5, 2.7, 3.0

    Range Depth Flange Lipmm mm mm

    S400 400 100 25

    S425 425 90 22.5

    S450 450 125 25

    S475 475 112.5 25

    S500 500 100 25

    Range Gauges mm

    S400 3.0, 4.0, 5.0

    S425 3.0, 4.0, 5.0

    S450 3.0, 4.0, 5.0

    S475 3.0, 4.0, 5.0

    S500 3.0, 4.0, 5.0

    Also Available Standard Super-Stud Range

  • SectionReference

    Weightkg/m

    Second Moment of Area

    Major Axiscm4

    Minor Axiscm4

    Major Axiscm3

    Minor Axiscm3

    Major Axiscm

    Minor Axiscm

    Major AxiskNm

    Section Modulus Radius of Gyration MomentCapacity

    1.31 14.99 3.72 4.00 1.32 3.05 1.52 1.691.56 17.77 4.38 4.74 1.56 3.04 1.51 2.271.92 21.72 5.31 5.79 1.89 3.01 1.49 3.112.03 40.6 28.62 8.12 2.59 4.03 1.85 3.472.51 50.00 10.53 10.00 3.16 4.00 1.84 4.953.28 64.66 13.44 12.93 4.04 3.96 1.81 7.272.58 77.91 12.36 12.47 3.54 4.94 1.97 5.502.77 83.58 13.22 13.37 3.78 4.93 1.96 6.212.96 89.17 14.07 14.27 4.03 4.92 1.96 6.913.14 94.68 14.90 15.15 4.27 4.92 1.95 7.613.51 105.49 16.52 16.88 4.73 4.90 1.94 8.973.88 116.00 18.07 18.56 5.17 4.88 1.93 10.292.58 107.99 11.12 14.40 3.17 5.82 1.87 6.152.79 116.64 11.98 15.55 3.41 5.81 1.86 7.053.00 125.18 12.82 16.69 3.65 5.80 1.86 7.943.20 133.62 13.64 17.82 3.88 5.79 1.85 8.823.41 141.96 14.45 18.93 4.11 5.78 1.84 9.693.81 158.33 16.01 21.11 4.56 5.77 1.83 11.404.21 174.30 17.52 23.24 4.99 5.75 1.82 13.073.33 194.42 22.69 22.22 5.01 6.87 2.35 8.173.58 208.85 24.32 23.87 5.37 6.86 2.34 9.473.83 223.14 25.92 25.50 5.72 6.85 2.33 10.754.07 237.29 27.50 27.12 6.07 6.84 2.33 12.014.56 265.15 30.58 30.30 6.75 6.82 2.32 14.515.04 292.44 33.56 33.42 7.41 6.81 2.31 16.965.75 332.32 37.87 37.98 8.36 6.78 2.29 20.546.22 358.20 40.62 40.94 8.97 6.76 2.28 22.863.36 250.36 23.62 25.04 4.93 7.77 2.39 8.03 3.90 290.98 27.32 29.10 5.71 7.76 2.38 11.214.17 311.02 29.13 31.10 6.09 7.75 2.37 12.784.44 330.86 30.91 33.09 6.46 7.74 2.37 14.334.97 370.01 34.40 37.00 7.19 7.72 2.35 17.405.50 408.43 37.78 40.84 7.90 7.70 2.34 20.406.28 464.69 42.66 46.47 8.92 7.68 2.33 24.816.79 501.30 45.79 50.13 9.58 7.66 2.31 27.684.75 454.10 45.36 40.36 7.98 8.78 2.77 14.035.05 483.33 48.18 42.96 8.47 8.77 2.77 16.075.66 541.10 53.70 48.10 9.45 8.75 2.76 20.096.26 597.92 59.09 53.15 10.40 8.73 2.74 24.057.16 681.40 66.91 60.57 11.78 8.70 2.73 29.877.75 735.90 71.95 65.41 12.67 8.69 2.72 33.675.54 652.43 61.44 52.19 9.81 9.73 2.98 17.726.21 730.90 68.55 58.47 10.95 9.71 2.97 22.636.88 808.22 75.50 64.66 12.06 9.69 2.96 27.487.86 922.03 85.61 73.76 13.68 9.66 2.94 34.628.52 996.47 92.14 79.72 14.73 9.65 2.93 39.299.81 1141.93 104.74 91.35 16.75 9.61 2.91 48.427.88 1300.52 95.30 86.70 14.10 11.48 3.11 35.159.02 1485.69 108.22 99.05 16.01 11.46 3.09 44.799.77 1607.12 116.59 107.14 17.26 11.44 3.08 51.131.26 1845.16 132.78 123.01 19.66 11.40 3.06 63.54

    10.18 2235.94 133.92 127.77 18.49 13.23 3.24 55.6111.03 2420.39 144.39 138.31 19.94 13.21 3.23 63.8311.88 2602.70 154.66 148.73 21.37 13.20 3.22 71.9712.72 2782.86 164.70 159.02 22.76 13.18 3.21 80.00

    S7510S7512S7515S10012S10015S10020S12513S12514S12515S12516S12518S12520S15012 S15013S15014S15015S15016S15018S15020S17513S17514S17515S17516S17518S17520S17523S17525S20012S20014S20015S20016S20018S20020S20023S20025S22515S22516S22518S22520S22523S22525S25016S25018S25020S25023S25025S25029S30020S30023S30025S30029S35023 S35025 S35027 S35029

    23 BW FramingTEL 01262 400088 EMAIL [email protected] WEB www.bw-industries.co.uk

    SFS Stud (S) Section Properties

  • Deeper top track section can also beprovided for use in conjunction withdeflection head brackets.

    SFS Track (T) Sections

    Range Depth Flangemm mm

    T79 79 36

    T104 104 42

    T129 129 48

    T154 154 54

    T179 179 52

    T204 204 66

    T229 229 68

    T254 254 80

    T306 306 74

    T356 356 81

    Range Gauges mm

    T79 1.0, 1.2, 1.5

    T104 1.2, 1.5, 2.0

    T129 1.3, 1.5, 2.0

    T154 1.2, 1.3, 1.4, 1.5, 1.6, 1.8, 2.0

    T179 1.3, 1.4, 1.5, 1.6, 1.8, 2.0

    T204 1.2, 1.3, 1.4, 1.5, 1.6, 1.8, 2.0, 2.3, 2.5

    T229 1.4, 1.5, 1.6, 1.8, 2.0, 2.3, 2.5

    T254 1.5, 1.6, 1.8, 2.0, 2.3, 2.5

    T306 1.6, 1.8, 2.0, 2.3, 2.5, 2.9

    T356 2.0, 2.3, 2.5, 2.9

    Range Depth Flangemm mm

    T406 406 88

    T431 431 75

    T456 456 97

    T481 481 84

    T506 506 72

    24BW Framing TEL 01262 400088 EMAIL [email protected] WEB www.bw-industries.co.uk

    Range Gauges mm

    T406 2.3, 2.5, 2.7, 3.0

    T431 3.0, 4.0, 5.0

    T456 3.0, 4.0, 5.0

    T481 3.0, 4.0, 5.0

    T506 3.0, 4.0, 5.0

    Also Available Standard Super-Track Range

    Deflection head brackets

  • SectionReference

    Weightkg/m

    Second Moment of Area

    Major Axiscm4

    Minor Axiscm4

    Major Axiscm3

    Minor Axiscm3

    Major Axiscm

    Minor Axiscm

    Section Modulus Radius of Gyration

    1.12 14.16 1.81 3.59 0.67 3.15 1.121.35 16.98 2.16 4.30 0.80 3.14 1.121.70 21.12 2.67 5.35 1.00 3.13 1.111.28 24.46 1.93 4.89 0.69 3.87 1.091.54 29.37 2.31 5.87 0.82 3.86 1.081.94 36.60 2.85 7.32 1.02 3.85 1.082.03 65.08 5.52 10.09 1.48 5.02 1.462.54 81.29 6.85 12.60 1.84 5.01 1.453.40 107.75 9.00 16.71 2.43 4.99 1.442.36 106.80 8.03 13.87 1.89 5.96 1.63 2.57 115.76 8.69 15.03 2.05 5.95 1.632.77 124.68 9.34 16.19 2.21 5.95 1.632.97 133.56 9.99 17.34 2.36 5.94 1.633.17 142.40 10.63 18.49 2.52 5.94 1.623.57 159.96 11.90 20.77 2.82 5.93 1.623.97 177.37 13.15 23.03 3.12 5.92 1.612.77 161.07 8.12 18.00 1.94 6.75 1.522.99 173.52 8.73 19.39 2.08 6.75 1.513.21 185.92 9.33 20.77 2.23 6.74 1.513.43 198.26 9.93 22.15 2.37 6.74 1.513.86 222.81 11.11 24.89 2.66 6.73 1.504.29 247.16 12.27 27.62 2.94 6.72 1.503.04 236.63 15.09 23.20 2.87 7.82 1.97 3.30 256.61 16.34 25.16 3.11 7.82 1.973.56 276.52 17.58 27.11 3.35 7.81 1.973.82 296.36 18.82 29.05 3.59 7.81 1.974.08 316.13 20.04 30.99 3.82 7.80 1.964.59 355.48 22.47 34.85 4.29 7.80 1.965.11 394.56 24.86 38.68 4.76 7.79 1.955.88 452.68 28.39 44.38 5.44 7.77 1.956.39 491.10 30.71 48.15 5.90 7.77 1.943.87 370.69 19.67 32.37 3.59 8.67 2.004.15 397.34 21.05 34.70 3.84 8.67 2.004.43 423.92 22.42 37.02 4.10 8.67 1.994.99 476.82 25.14 41.64 4.60 8.66 1.995.55 529.40 27.83 46.24 5.10 8.65 1.986.39 607.66 31.79 53.07 5.84 8.64 1.986.95 659.43 34.39 57.59 6.32 8.63 1.974.71 564.71 34.02 44.47 5.32 9.70 2.385.03 602.59 36.26 47.45 5.67 9.70 2.385.67 678.02 40.69 53.39 6.37 9.69 2.376.31 753.04 45.08 59.29 7.07 9.68 2.377.26 864.81 51.57 68.10 8.10 9.67 2.367.90 938.81 55.83 73.92 8.78 9.66 2.365.52 895.72 30.42 58.54 4.96 11.29 2.086.22 1008.15 34.12 65.89 5.57 11.28 2.076.92 1120.03 37.78 73.20 6.18 11.27 2.077.97 1286.83 43.20 84.11 7.08 11.26 2.068.67 1397.36 46.75 91.33 7.67 11.25 2.06

    10.06 1616.80 53.74 105.67 8.84 11.23 2.057.91 1707.06 50.45 95.90 7.47 13.02 2.249.11 1962.19 57.72 110.24 8.56 13.00 2.239.91 2131.38 62.50 119.74 9.28 13.00 2.23

    11.50 2467.59 71.91 138.63 10.70 12.98 2.22

    T7910T7912T7915T10410T10412T10415T12912T12915T12920T15412 T15413T15414T15415T15416T15418T15420T17913T17914T17915T17916T17918T17920T20412T20413T20414T20415T20416T20418T20420T20423T20425T22914T22915T22916T22918T22920T22923T22925T25415T25416T25418T25420T25423T25425T30616T30618T30620T30623T30625T30629T35620 T35623 T35625 T35629

    SFS Track (T) Section Properties

    25 BW FramingTEL 01262 400088 EMAIL [email protected] WEB www.bw-industries.co.uk

  • Partition and Dry Lining walls aremade up from light gauge sectionsthat create the internal walls inresidential, industrial andcommercial structures.

    BW Industries Partition and DryLining range lead the way in lightgauge pre-galvanised steelsections. It can be used to makenon load bearing walls inrefurbishment and new builddevelopments.

    There are many advantages thatcome with using BW PartitionSections such as minimal snagging, no shrinking or splitting and alsothe resistance of fire, insects androt. They can be easily insulatedand boarded to achieve fire andacoustics ratings subject tospecification requirements.

    Our cold formed galvanisedcomponents are roll formed in stick form for assembly on site. We produce them cut to length tosuit individual applications in eitherplain lengths or pre-punched forservices etc.

    This modern technique ofmanufacture allows for fabricationof components to much bettertolerances than traditional methodsof construction.

    Speed on site and ease ofinstallation reduces costs, makingthe BW Industries system a timeand cost effective solution againstdirect material comparisons.

    26BW Framing TEL 01262 400088 EMAIL [email protected] WEB www.bw-industries.co.uk

    Partition and Dry Lining SectionsOverview

  • BW Industries Partition and Dry Lining sections range in depth from 50mm to 100mm with a range of gauges from 0.5mm to 1.2mm

    Used to make non-load bearing walls in refurbishment and new build developments

    Sections provide long term flexibility and ease of adaption and are dimensionally accurate

    Freedom from shrinkage and splitting

    Weight reduction in comparison to masonry and concrete methods

    Safer and easier site installations

    Resistance against fire, insects and rot

    More time and cost effective to traditional methods of construction

    Fast construction on site which results in earlier completion times

    Increased stability and durability

    Sections are light gauge cold-formed pre-galvanised steel sheet with a Z275 coating

    The stated gauges are core steel thickness plus the standard (Z275) zinc coating thickness of 0.04mm

    Sections are generally manufactured from grade S450 steel with a minimum yield strength of 450M/mm

    27 BW FramingTEL 01262 400088 EMAIL [email protected] WEB www.bw-industries.co.uk

    Partition and Dry Lining SectionsKey Facts and Benets

  • Partition Walls and Dry Lining

    Dry Lining

    Internal Partition WallBW steel partitioning is ideal for domestic and commercialapplications allowinginternal partitioning to be erected efficientlyand with minimum costs

    Dry Lining is suitable formany different types of buildings and can be used for manyapplications such as to line uneven walls,masonry backgroundsand concealing services

    28BW Framing TEL 01262 400088 EMAIL [email protected] WEB www.bw-industries.co.uk

  • Partition and Dry Lining (P) Sections

    29 BW FramingTEL 01262 400088 EMAIL [email protected] WEB www.bw-industries.co.uk

    Range Depth Flangemm mm

    P54 54 40

    P74 74 40

    P94 94 40

    P104 104 40

    Range Gauges mm

    P54 0.5, 0.6, 0.8, 0.9, 1.0, 1.2

    P74 0.5, 0.6, 0.8, 0.9, 1.0, 1.2

    P94 0.5, 0.6, 0.8, 0.9, 1.0, 1.2

    P104 0.5, 0.6, 0.8, 0.9, 1.0, 1.2

    Range Depth Flange Lipsmm mm mm

    P50 50 50 10

    P70 70 50 10

    P90 90 50 10

    P100 100 50 10

    Range Gauges mm

    P50 0.5, 0.6, 0.8, 0.9, 1.0, 1.2

    P70 0.5, 0.6, 0.8, 0.9, 1.0, 1.2

    P90 0.5, 0.6, 0.8, 0.9, 1.0, 1.2

    P100 0.5, 0.6, 0.8, 0.9, 1.0, 1.2

  • 30BW Framing TEL 01262 400088 EMAIL [email protected] WEB www.bw-industries.co.uk

    Fire Restraint Wall System Literature

    Other publicationsA range of other publications for cold rolled sections including safe load tables are available on ourwebsite.

    To download brochures from our website please visit

    www.bw-industries.co.uk/downloads-brochures

  • 31 BW FramingTEL 01262 400088 EMAIL [email protected] WEB www.bw-industries.co.uk

    Software

    BW Building WizardSoftwareThe software package facilitates costeffective design of purlins, side railsand mezzanine floor beams all inaccordance with current standards.

    An integral database allows for quickand accurate assessment of loadingsincluding wind load and snow load forall locations in the United Kingdom andIreland. This all in one applicationenables production of detailed reportsfor submission to any checkingauthority.

    See our website or contact our salesteam to request the latest version.

    The Building Wizard Software is available to download from our website at

    www.bw-industries.co.uk/downloads-software

  • We reserve the right to alter and amend specifications shown at any timewithout prior notice. All dimensions are nominal. Care has been taken that thecontents of this publication are accurate. However BW Industries Ltd. and itsassociated companies do not accept responsibility for errors or informationfound to be misleading and accept no liabilities whatsoever in respect thereof. The contents of this publication are meant as a generalintroduction to our products and any purchaser, specifier or user retains the entire responsibility for satisfying themselves, independently of anythingherein, as to the suitability or fitness for purpose of any BW Industries Ltd.products, services or systems. Our normal terms and conditions of businessapply to any order (A copy will be supplied upon request.) February 2014

    BW INDUSTRIESCarnaby Industrial Estate

    Carnaby, Bridlington

    East Yorks. YO15 3QY

    TEL 01262 400088

    FAX 01262 401110

    EMAIL [email protected]

    WEB www.bw-industries.co.uk