© Luxom LTF_EN_DS65L.doc8 Telefoon : +322 460 31 75, Fax : +322 403 08 78, www.luxom.be 1 . BUS – Ethernet Gateway DS 65L TECHNI This module allows you to communicate with the Luxom system over TCP/IP. You can connect up to 9 devices at the same time. All Luxom modules can be controlled and programmed using the master port: 2300. This port allows only one user at the same time. All Luxom modules can be controlled using port: 2301. This port allows maximum 8 users at the same time. 4 TECHNICAL DATA Product ID B3 firmware versi : DS65LI 02.16.05 Power supply 24 VDC Power consumption 2.2 VA Installation DIN-rail mount Number of bus connection 3 Screw connector BUS 2.5 mm² Add-on connector 1 or 0 – not used Connector LAN (Ethernet) RJ45 10/100 Base-T Hardware protocols TCP, IP, ARP, UDP, ICMP, MAC Active bustermination Yes User ID - password Yes (from PlusConfig 3.2.xx) Static IP address Yes Dynamic IP address Yes Numer of simmultane connections via Ethernet 1 via masterport 2300, 8 via slave port 2301 Warranty 3 year on exchange Ambiant temperature 0 - 50° C Protection IP 20 Dimensions LxWxH 72 x 90 x 62 mm Number of DIN-rail modules 18 mm 4 Benefits : - An even greater flexibility because an existing IP infrastructure can be used. - Uses the international IP standard protocol. - Wireless communication with the Luxom system via WLAN. This module has a configurable ‘TCP/IP address’, ‘Default Gateway’ and ‘Network ID’ settings. This module has a built-in active termination unit. A wired bridge is required (on the ‘I’ connector) to activate the internal termination. Your Luxom Bus is operational and ready to communicate via IP as soon as 24VDC is connected to this IP router. CONTROL LEDs I Bus current (extinguishes with short circuit between S and – bus wire) U Bus tension (extinguishes with short circuit between + and – bus wire) Q1-Q4 N/A with this version I1-I4 N/A with this version
10

BUS – Ethernet Gateway DS 65L · LTF_EN_DS65L.doc8 Telefoon : +322 460 31 75, Fax : +322 403 08 78, 1 . BUS – Ethernet Gateway DS 65L . TECHNI&$/ '(6&5,37,21: This module allows

Jun 11, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: BUS – Ethernet Gateway DS 65L · LTF_EN_DS65L.doc8 Telefoon : +322 460 31 75, Fax : +322 403 08 78, 1 . BUS – Ethernet Gateway DS 65L . TECHNI&$/ '(6&5,37,21: This module allows

© Luxom LTF_EN_DS65L.doc8

Telefoon : +322 460 31 75, Fax : +322 403 08 78, www.luxom.be

1

. BUS – Ethernet Gateway DS 65L

TECHNICAL DESCRIPTION This module allows you to communicate with the Luxomsystem over TCP/IP. You can connect up to 9 devicesat the same time. All Luxom modules can be controlled and programmedusing the master port: 2300. This port allows only one userat the same time. All Luxom modules can be controlled using port: 2301.This port allows maximum 8 users at the same time.

4

TECHNICAL DATA Product ID B3

Manual valid for firmware versions: DS65LI 02.16.05or higher

Power supply 24 VDC Power consumption 2.2 VA Installation DIN-rail mountNumber of bus connection 3 Screw connector BUS 2.5 mm² Add-on connector 1 or 0 – not used Connector LAN (Ethernet) RJ45 10/100 Base-T Hardware protocols TCP, IP, ARP, UDP, ICMP, MAC Active bustermination Yes User ID - password Yes (from PlusConfig 3.2.xx) Static IP address Yes Dynamic IP address YesNumer of simmultane connections via Ethernet 1 via masterport 2300, 8 via slave port 2301 Warranty 3 year on exchange Ambiant temperature 0 - 50° C Protection IP 20 Dimensions LxWxH 72 x 90 x 62 mm Number of DIN-rail modules 18 mm 4

Benefits :

- An even greater flexibility because an existing IP infrastructure can be used.

- Uses the international IP standard protocol. - Wireless communication with the Luxom

system via WLAN. This module has a configurable ‘TCP/IP address’, ‘Default Gateway’ and ‘Network ID’ settings. This module has a built-in active termination unit. A wired bridge is required (on the ‘I’ connector) to activate the internal termination. Your Luxom Bus is operational and ready to communicate via IP as soon as 24VDC is connected to this IP router.

CONTROL LEDs

I Bus current (extinguishes with short circuit between S and – bus wire) U Bus tension (extinguishes with short circuit between + and – bus wire) Q1-Q4 N/A with this version I1-I4 N/A with this version

Page 2: BUS – Ethernet Gateway DS 65L · LTF_EN_DS65L.doc8 Telefoon : +322 460 31 75, Fax : +322 403 08 78, 1 . BUS – Ethernet Gateway DS 65L . TECHNI&$/ '(6&5,37,21: This module allows

© Luxom LTF_EN_DS65L.doc8

Telefoon : +322 460 31 75, Fax : +322 403 08 78, www.luxom.be

2

-

LOCAL COMMUNICATION

CONNECTION VIA CABLE- or DSL MODEM

You need to know the cable/DSL modem’s IP address to be able to communicate with a Luxom network from the internet. A standard internet provider’s account does not usually provide you with a fixed IP Address. This means you will have to use extra tools to connect to your Luxom environment. For more information please contact your Luxom specialist. In this picture an IP router with built-in modem is used. This is not necessary, and can be two separate devices.

WIRELESS CONNECTION (WIFI)

WHAT ARE THE ORANGE AND GREEN LED ON THE LAN CONNECTOR FOR?

ORANGE LED This LED lights up whenever the module is connected to a LAN network. The module is NOT connected to the LAN network when this LED is not lit. GREEN LED Blinks when there is communication between the module and the LAN network.

Page 3: BUS – Ethernet Gateway DS 65L · LTF_EN_DS65L.doc8 Telefoon : +322 460 31 75, Fax : +322 403 08 78, 1 . BUS – Ethernet Gateway DS 65L . TECHNI&$/ '(6&5,37,21: This module allows

© Luxom LTF_EN_DS65L.doc8

Telefoon : +322 460 31 75, Fax : +322 403 08 78, www.luxom.be

3

You'll have to login using: User Name = userPassword = luxom The home page of the DS65L opens: see image below. Select “Network”.

HOW TO CHANGE THE IP SETTINGS FOR MODULE DS65L? This modules default IP address from factory is: 192.168.1.101 Gateway: 192.168.1.1

5 -step procedure to configure the IP address::

1- Connect the computer to the module with a ‘straight’ or ‘crossed’ patch cable:

2- Set the computer’s IP address to: 192.168.1.100

3- Go to your browser (E.g.: Internet Explorer) en type the module’s IP address: 192.168.1.101

4- Press ‘ENTER’ to make the following screen appear:

Page 4: BUS – Ethernet Gateway DS 65L · LTF_EN_DS65L.doc8 Telefoon : +322 460 31 75, Fax : +322 403 08 78, 1 . BUS – Ethernet Gateway DS 65L . TECHNI&$/ '(6&5,37,21: This module allows

© Luxom LTF_EN_DS65L.doc8

Telefoon : +322 460 31 75, Fax : +322 403 08 78, www.luxom.be

4

(*) When you fill in 0 sec. as session timeout, there will be no timeout.

In this window you can change:

IP Adres, Subnet Mask,

Default Gateway, Primary DNS, Secondary DNS, Session

timeout(*) and Network Id (**)

(**) Network Id (also NID ) is a number that precedes all communication from the DS65L module. (N/A for standard applications)

5- When you’ve changed the settings and clicked on ‘Apply’, the following

message appears:

Page 5: BUS – Ethernet Gateway DS 65L · LTF_EN_DS65L.doc8 Telefoon : +322 460 31 75, Fax : +322 403 08 78, 1 . BUS – Ethernet Gateway DS 65L . TECHNI&$/ '(6&5,37,21: This module allows

© Luxom LTF_EN_DS65L.doc8

Telefoon : +322 460 31 75, Fax : +322 403 08 78, www.luxom.be

5

http://www.luxom.be/partnerpages/default.aspx?CatID=23#item9 You'll need to be logged in to download.

If you don't have login yet, you can obtain one by filling in the contact form. Just use the link below. http://www.luxom.be/login.aspx?page=/default.aspx

This message informs you the module will reboot. The orange and green LEDs on the LAN connector allow you to follow the reboot process. When clicking ‘Apply’ both LEDs light up after approximately 18 seconds for a period of about 12 seconds. When after this period the orange LED extinguishes for 5 seconds and then lights up again while the green LED starts blinking, the module has fully rebooted. In some cases it can be that you need to power themodule down and up again.

Note: When changing one of the first 9 digits in the module’s IP address, make sure you do the same in your computer’s IP address. Neglecting to do so will result in the impossibility to communicate with the module. For example: when you change the module’s IP address from 192.168.1.101 to 192.168.123.101, you also need to change your computer’s IP address from 192.168.1.100 to 192.168.123.100.

HOW TO FIND THE MODULE’S MAC ADDRESS?

1- Download software DS65L_IPconfig from our website, using the following link:

2- Unzip this file and save to you hard drive: c:\ 3- Go to Start/All programs/Accessories/Command Prompt and type:

C:\DS65L_IPConfig/discover

push ENTER

4- The following message appears, displaying both the module’s IP and MAC address:

Page 6: BUS – Ethernet Gateway DS 65L · LTF_EN_DS65L.doc8 Telefoon : +322 460 31 75, Fax : +322 403 08 78, 1 . BUS – Ethernet Gateway DS 65L . TECHNI&$/ '(6&5,37,21: This module allows

© Luxom LTF_EN_DS65L.doc8

Telefoon : +322 460 31 75, Fax : +322 403 08 78, www.luxom.be

6

Firmware version:

DS65LI 02.16.05

HOW TO FIND THE MODULE’S FIRMWARE VERSION?

Connect to the module using the PlusConfig software and go to Tools/Options in the menu toolbar:

Page 7: BUS – Ethernet Gateway DS 65L · LTF_EN_DS65L.doc8 Telefoon : +322 460 31 75, Fax : +322 403 08 78, 1 . BUS – Ethernet Gateway DS 65L . TECHNI&$/ '(6&5,37,21: This module allows

© Luxom LTF_EN_DS65L.doc8

Telefoon : +322 460 31 75, Fax : +322 403 08 78, www.luxom.be

7

Zie onderstaande afbeelding;

Available from PlusConfig 3.2.1 or higher!

HOW TO PASSWORD PROTECT THIS MODULE?

Go to:

Enter your password twice an click on ‘OK’:

This password must be entered every time you whish to connect to the module:

If you fail to do so, access will be denied and a lock symbol will appear at the bottom left of your screen.

CHANGING THE IP ADDRESS. DS65L with firmware DS65LI 01.xx.xx

1- Download software DS65L_IPconfig from our website as mentioned before.

2- Unzip this file and save to you hard drive: c:\ 3- Go to Start/All programs/Accessories/Command Prompt and type:

C:\DS65L_IPConfig/set /mac=auto /ip=192.168.1.201 (**)

!spaces must be entered!

Page 8: BUS – Ethernet Gateway DS 65L · LTF_EN_DS65L.doc8 Telefoon : +322 460 31 75, Fax : +322 403 08 78, 1 . BUS – Ethernet Gateway DS 65L . TECHNI&$/ '(6&5,37,21: This module allows

© Luxom LTF_EN_DS65L.doc8

Telefoon : +322 460 31 75, Fax : +322 403 08 78, www.luxom.be

8

Firmware upgrade Digiconn

Download software DS65L_IPconfig from our website using this link:

http://www.luxom.be/partnerpages/default.aspx?CatID=23#item9

You'll need to be logged in to download. If you don't have login yet, you can obtain one by filling in the contact form. Just use the link below. http://www.luxom.be/login.aspx?page=/default.aspx Download the DS65L upgrade Digiconn file. (image.bin) using this link: http://www.luxom.be/partnerpages/default.aspx?CatID=23#item204

Unzip the file and save on you hard disc: c:\

Using the command above the module’s IP address will be changed to 192.168.1.201

Press ENTER

The following messages are displayed: "NET+OS Programmer" "Version..." "Copyright..." "Searching for devices. Please wait..." (this might take a moment) "Locate device (auto): Searching for devices. Please Wait ..." "Locate device (auto) SUCCESS" (this might take a moment) "Device has been rebooted" (takes about 20 sec) "IP adress has been changed"

The IP addess has been changed to 192.168.1.201

Caution: This procedure takes about 1 minute to complete. Please wait until the DOS prompt reappears (c:\). Only then will the module be operational again.

(**) In case there is text after “C:\“, such as “C:\Documents and settings\xxx”, please type cd\ and push Enter to delete it. Resume step 3.

Page 9: BUS – Ethernet Gateway DS 65L · LTF_EN_DS65L.doc8 Telefoon : +322 460 31 75, Fax : +322 403 08 78, 1 . BUS – Ethernet Gateway DS 65L . TECHNI&$/ '(6&5,37,21: This module allows

© Luxom LTF_EN_DS65L.doc8

Telefoon : +322 460 31 75, Fax : +322 403 08 78, www.luxom.be

9

Go to Start/All programs/Accessories/Command Prompt and type:

C:\DS65L_IPConfig/discover

Press ENTER

You will see the IP and the MAC address of the module: (if you already know the IP-adres of the module you can skip this step)

For a DS65L with firmware version 02.07.05 or older type ftp and the IP address of the module and press enter. To do this your computers IP-address should be in the same range as the IP-address of the module. As user type (none) and press enter. A responce with logged in will appear. Then type bin and press enter, type will be set to 1. After this type put image.bin and press enter. The upgrade will load. To finish type quit and press enter. See image below.

Page 10: BUS – Ethernet Gateway DS 65L · LTF_EN_DS65L.doc8 Telefoon : +322 460 31 75, Fax : +322 403 08 78, 1 . BUS – Ethernet Gateway DS 65L . TECHNI&$/ '(6&5,37,21: This module allows

© Luxom LTF_EN_DS65L.doc8

Telefoon : +322 460 31 75, Fax : +322 403 08 78, www.luxom.be

10

For a DS65L with firmware version 02.15.05 or older type ftp and the IP address of the module and press enter. To do this your computers IP-address should be in the same range as the IP-address of the module. As user type root and press enter.You'll need to give password. The password is Netsilicon (the N of Netsilicon is capital). When you type this you'll notice that this will not appear on your screen. Press enter. You should get password OK.Then type bin and press enter, type will be set to 1. After this type put image.bin and press enter. The upgrade will load. To finish type quit and press enter. See image below.