Top Banner
Burners Blast pilots PBC & PBST (E3280 rev. 03 - 23/04/2018)
28

Burners - esapyronics.com · dents and environmental safeguarding. ... Equipment for industrial thermal process ... FLOW SCHEME FOR BURNER WITH INCORPORATED MIXER ...

Aug 27, 2018

Download

Documents

phamkien
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Burners - esapyronics.com · dents and environmental safeguarding. ... Equipment for industrial thermal process ... FLOW SCHEME FOR BURNER WITH INCORPORATED MIXER ...

Burners

Blast pilotsPBC & PBST (E3280 rev. 03 - 23/04/2018)

Page 2: Burners - esapyronics.com · dents and environmental safeguarding. ... Equipment for industrial thermal process ... FLOW SCHEME FOR BURNER WITH INCORPORATED MIXER ...

PBC & PBST E3280 rev. 03 - 23/04/18

www.esapyronics.com 2

GENERAL WARNINGS:

¾¾ All installation, maintenance, ignition and setting mustbe performed by qualified staff, respecting the norms

present at the time and place of the installation.

¾¾ To avoid damage to people and things, it is essentialto observe all the points indicated in this handbook. The

reported indications do not exonerate the Client/User

from observing general or specific laws concerning acci-

dents and environmental safeguarding.

¾¾ The operator must wear proper DPI clothing (shoes,helmets...) and respect the general safety, prevention

and precaution norms.

¾¾ To avoid the risks of burns or high voltage electrocu-tion, the operator must avoid all contact with the burner

and its control devices during the ignition phase and

while it is running at high temperatures.

¾¾ All ordinary and extraordinary maintenance must beperformed when the system is stopped.

¾¾ To assure correct and safe use of the combustionplant, it is of extreme importance that the contents of this

document be brought to the attention of and be meticu-

lously observed by all personnel in charge of controlling

and working the devices.

¾¾ The functioning of a combustion plant can be dange-rous and cause injuries to persons or damage to equip-

ment. Every burner must be provided with certified com-

bustion safety and supervision devices.

¾¾ The burner must be installed correctly to prevent anytype of accidental/undesired heat transmission from the

flame to the operator or the equipment.

¾¾ The performances indicated in this technical docu-ment regarding the range of products are a result of

experimental tests carried out at ESA-PYRONICS. The

tests have been performed using ignition systems, flame

detectors and supervisors developed by ESA-PYRO-

NICS. The respect of the above mentioned functioning

conditions cannot be guaranteed if equipment, which is

not present in the ESA-PYRONICS catalogue, is used.

CONTACTS / SERVICE:

To dispose of the product, abide by the local legislations

regarding it.

DISPOSAL:

Headquarters:

Esa S.p.A.

Via Enrico Fermi 40

24035 Curno (BG) - Italy

Tel +39.035.6227411

Fax +39.035.6227499

[email protected]

International Sales:

Pyronics International s.a.

Zoning Industriel, 4ème rue

B-6040 Jumet - Belgium

Tel +32.71.256970

Fax +32.71.256979

[email protected]

www.esapyronics.com

GENERAL NOTES:

CERTIFICATIONS:

¾¾ In accordance to the internal policy of constant quali-ty improvement, ESA-PYRONICS reserves the right to

modify the technical characteristics of the present docu-

ment at any time and without warning.

¾¾ It is possible to download technical sheets which havebeen updated to the latest revision from the www.esa-

pyronics.com website.

¾¾ The products manufactured by ESA-PYRONICShave been created in conformity to the UNI EN 746-2:2010 Norms: Equipment for industrial thermal process- Part 2: Safety requirements for combustion and themovement and treatment of combustible elements. Thisnorm is in harmony with the Machine Directive2006/42/CE. It is certified that the products in questionrespect all the requirements prescribed by the abovementioned Norms and Directives.

¾¾ Certified in conformity with the UNI EN ISO 9001Norm by DNV GL.

The products conform to the requests for the Euroasia market

(Russia, Belarus and Kazakhstan).

Page 3: Burners - esapyronics.com · dents and environmental safeguarding. ... Equipment for industrial thermal process ... FLOW SCHEME FOR BURNER WITH INCORPORATED MIXER ...

PBC & PBST E3280 rev. 03 - 23/04/18

www.esapyronics.com 3

APPLICATIONS

The PBC & PBST series identifies a range of premix bur-

ners that are mainly used as pilot flames to ignite burners

with larger capacities. The particular conformation of the

combustion head guarantees excellent flame retention,

high resistance to temperature changes and long life.

¾¾Main burner blast pilot.

¾¾Billet heating.

¾¾Glass furnaces.

¾¾Bunsen burner casting.

CHARACTERISTICS

GENERAL:

¾¾Capacity: from 1 to 15 kW

¾¾Combustion gas: CH4/GPL/Propane

¾¾Ignition/Detection: monoelectrode

¾¾Max. temperature used: 1100°C

¾¾Excellent flame stability

¾¾Maximum air inlet pressure: 360 mbar

¾¾Maximum gas inlet pressure: 100 mbar

MATERIAL COMPOSITION:

¾¾Combustion head: AISI310/Aluminium oxide 96%

¾¾Flame tube: AISI304/INCOLOY 601

F3280I03

F3280I04

PBC-MX

PBC & PBST

Page 4: Burners - esapyronics.com · dents and environmental safeguarding. ... Equipment for industrial thermal process ... FLOW SCHEME FOR BURNER WITH INCORPORATED MIXER ...

PBC & PBST E3280 rev. 03 - 23/04/18

www.esapyronics.com 4

FLOW SCHEME - CERAMIC BLAST PILOTS WITH EXTERNAL MIXER

CAPACITY PARAMETERS

ModelMax capacity

[kW]

Flame length

[mm]

Ignition/Detection

electrode

P32PBC 1 20÷30 32CWFR & 32CWFR/X

P42PBC 2 30÷40 42CWFR & 42CWFR/X

P64PBC 5 50÷70 64CWFR & 64CWFR/X

P86PBC 10 80÷100 86CWFR & 86CWFR/X

P64PBST 5 50÷70 10MM

P86PBST 10 80÷100 10MM

P108PBST 15 100÷120 6EN/10MM

P42PBC-MX-FR 2 30÷40 42CWFR-MX/X

P64PBC-MX-FR 5 50÷70 64CWFR-MX/X

P86PBC-MX-FR 10 80÷100 86CWFR-MX/X

Coupled with MM or FLOWMIXER mixers, the PBC &

PBST burners develop maximum flame capacity at rou-

ghly 15 mbar premix pressure.

The burners remain stable with mixed pressures betwe-

en 10 and 20mbar.

esa-estro

MA

IN A

IR L

INE

MA

IN G

AS

LIN

E

1 2 34 5

6 7 8 9 10

11

12 13

Pos. Description Included Not Included

1 Gas flexible hose (*) x

2 Gas interception valve x

3 Solenoid safety valve (**) x

4 Zerogovernor x

5 Micrometric regulation screw x

6 Flexible air hose (*) x

7 Air interception valve x

8 Pressure stabilizer x

9 Venturi mixer x

10 Extensible flexible hose x

11 Pilot burner x

12 Flame control x

13 Ignition transformer x

D3280I01

(*) Client’s responsibility

(**) Optional

Page 5: Burners - esapyronics.com · dents and environmental safeguarding. ... Equipment for industrial thermal process ... FLOW SCHEME FOR BURNER WITH INCORPORATED MIXER ...

PBC & PBST E3280 rev. 03 - 23/04/18

www.esapyronics.com 5

PBC-MX PILOT WITH INCORPORATED MIXER

The pilot PBC-MX is equipped with a separate air and

gas inlet. The mixing of the fuel and combustion occurs

within the body of the burner, without the aid of an exter-

nal mixer. For this reason, the pressures of the combu-

stion air and fuel lines must be suitably stabilized using

special pressure stablizers: pressure that is not constant

within the collectors can create problems in flame insta-

bility. Furthermore, to ensure correct operation of the pilot

burner, the air and gas pressures that feed it must be

higher than the pressure present in the main burner con-

nection zone. Ignition and flame detection are done

through the use of an electrode (unirod configuration).

The electrode is easily replaceable from outside.

The gas inlet is provided with a micrometric regulation

valve , so we can use the pilot with different types of gas

fuels (with lower calorific value however not less than

4000kcal / m3).

To prevent the internal organs of the pilot burner and its

regulation bodies from getting dirty, we recommended

the use of special filters on the air and gas power lines.

F3280I08

Page 6: Burners - esapyronics.com · dents and environmental safeguarding. ... Equipment for industrial thermal process ... FLOW SCHEME FOR BURNER WITH INCORPORATED MIXER ...

PBC & PBST E3280 rev. 03 - 23/04/18

www.esapyronics.com 6

FLOW SCHEME FOR BURNER WITH INCORPORATED MIXER - PBC-MX

MA

IN P

ILO

T A

IR L

INE

MA

IN P

ILO

T G

AS

LIN

E

142

S S

1

4

3

5 6 7

8 910 11

9

1213

Pos. Description Included Not Included

1 Air filter x

2 Air pressure stabilizer x

3 Gas filter x

4 Gas pressure stabilizer x

5 Air interception valve x

6 Gas regulation valve x

7 Air flexible pipe x

8 Gas interception valve x

9 Safety solenoid valve (**) x

10 Gas flexible pipe x

11 Gas micrometric valve x

12 Flame control device x

13 Ignition transformer x

14 Pilot burner x

(*) Client’s responsibility

(**) Optional

D3280I02

Page 7: Burners - esapyronics.com · dents and environmental safeguarding. ... Equipment for industrial thermal process ... FLOW SCHEME FOR BURNER WITH INCORPORATED MIXER ...

PBC & PBST E3280 rev. 03 - 23/04/18

www.esapyronics.com 7

WARNINGS

¾¾ - For all applications at low temperatures (up to 750°C),the burner ignition and the gas fuel solenoid valve com-

mand must be carried out using a certified burner control

device.

¾¾ - To avoid any possible damage to the burners, makesure that the air is not preheated or foul due to combu-

stion products, oils, solvents or other. To avoid these phe-

nomena, it is preferable to install the blower or suction

duct outside the premises and far from exhaust pipes, or

else to fit filters upstream the premix group. If the atomi-

zing air should come from the compressed air lines,

NEVER exceed the maximum allowable pressure

Pmax=360 [mm].

¾¾ - After installation, check that the power feeding linesare connected correctly. Before switching the burner on

check that the combustion air and fuel pressure values

are correct.

¾¾ - The burner must only function within the indicatedpower ranges. Working with lower or higher power may

compromise the functioning and life span of the burner, in

which case the general guarantee conditions will automa-

tically expire and ESA-PYRONICS will not be held liable

for possible damage caused to persons and objects.

¾¾ - Should there be disturbances with other devicesduring the burner start-up phase, use an anti-disturbance

filter for the high voltage cable (hv) connection to the igni-

tion electrode.

¾¾ - Avoid burner ignition close to each other so as not toheat the ignition command system devices (solenoid val-

ves and transformers). Prewash time lapse + first safety

time lapse + min. of 5 sec. = time lapse between one igni-

tion and another. (However, do not attempt more than 2

ignitions during a 30sec. time lapse).

¾¾ - Make sure the power supply is TURNED OFF whenintervening on the burner and its devices. In case of bur-

ner malfunctioning, follow the indications in the

‘Maintenance’ chapter of the present manual or contact

ESA-PYRONICS assistance.

¾¾ - Any modification or repair done by third parties cancompromise the application safety and automatically

cause the general warrantee conditions to expire. Contact

ESA-PYRONICS assistance.

INSTALLATION

The PBC and PBST pilot burners are provided with threa-

ded fastening fittings. It is possible to create fasteners

according to specific needs. We do not recommend

mounting with the flame pointing upwards as condensa-

tion phenomena could create problems with ignition and

detection avoiding thus foreign materials from getting into

the burner flame tube and obstructing it.

For the connection of the mixing pipes we recommend

using extendable flexible fittings: the connections betwe-

en the burner and the mixer must have at least the same

diameter as the output of the mixer.

Do not put valves or any type of restrictions on the mixing

pipes.

For the PBC/X & PBST/X (with variable lengths and sli-

ding anchoring coupling) make sure that the pilot burner

output is not in direct contact with the flame of the main

burner, to preserve the integrity of the metallic tube.

The burner head must not be in contact with the main

flame as being a premix burner, the flame tube which is

placed before the combustion head, must not be subject

to temperatures higher than 500°C. This avoids pheno-

mena of self-priming of the mixture.

If necessary provide adequate cooling on the outside of

the flame tube. In any case, with the pilot burner off, make

sure that the combustion air continues to flow though the

inside of the pilot burner.

Page 8: Burners - esapyronics.com · dents and environmental safeguarding. ... Equipment for industrial thermal process ... FLOW SCHEME FOR BURNER WITH INCORPORATED MIXER ...

PBC & PBST E3280 rev. 03 - 23/04/18

www.esapyronics.com 8

IGNITION - SETTING

The procedures indicated in the following chapter must be

carried out by expert technicians. The non-observance of

the instructions given can provoke dangerous conditions.

1 - Check the safety solenoid valve (if present), ignition

electrode and flame control electrical connections.

2 - Check for an air minimum feeding pressure of 36mbar

and a gas minimum feeding pressure 20mbar.

3 - Open the main air valve.

4 - Open the air stabilizer cap ("A").

5 - Adjust the spring regulation (screwing on or unscre-

wing the regulation plug) until reaching a mix-pressure of

10÷15 mbar on the pressure plug (pos. 01) with "burner

OFF". Screwing on increases the pressure/unscrewing

decreases the pressure.

6 - The gas pressure with burner off (pos.02) must be

negative. The air inlet pressure (pos.03) must be 40÷50

mbar.

7 - Open the main gas valve.

8 - Switch the burner on with the start button found on the

flame control device, opening the gas throttle valve nee-

dle ("B") very slowly, during ignition (repeat the step until

you see a stable flame on the pilot burner).

9 - Adjust the gas flow via the gas throttle valve screw cap

to reach the highest detection value on the flame control.

10 - To obtain an excellent flame, adjust the gas flow in

the following conditions:

A - Excess of air: short blue flame that disappears into the

pilot tube (low detection).

B - Right ratio: light blue tense flame with a good detec-

tion (40÷60 mA).C - Excess of gas: long blue-green flame near flame deta-

chment (low detection).

11 - Once the right regulation has been reached, check

for a mix-pressure of 15÷20 mbar (pos.01) with "burner

on". Adjust the air stabilizer screw if necessary.

12 - Turn off the burner and make sure it starts again,

checking for several positive ignitions.

13 - Make sure there is pressure downstream the zero-

governor (pos.02). The right value is similar to the mix-

pressure value that is set in the air regulation (it can be

adjusted by adjusting the zero-governor spring position).

VENT

AIR INLET

VENT

GAS INLET

1 3

2 MAIN GAS VALVE

MAIN AIR VALVE

"A" AIR STABILIZER

GAS ZEROGOVERNOR

TO THE PILOT BURNER

"B"

SAFETY SOLENOID

VALVE (OPTIONAL)

esa-estro

START BUTTON

D3280C03

Excess of air Right ratio Excess of gas

F3280I07F3280I06F3280I05

Page 9: Burners - esapyronics.com · dents and environmental safeguarding. ... Equipment for industrial thermal process ... FLOW SCHEME FOR BURNER WITH INCORPORATED MIXER ...

PBC & PBST E3280 rev. 03 - 23/04/18

www.esapyronics.com 9

IGNITION - SETTING OF THE PILOT WITH INCORPORATED MIXER - PBC-MX

The procedures indicated in the following chapter must be

carried out by expert technicians. The failure to follow

instructions can cause dangerous conditions.

1 - Check the safety solenoid valve (if present), the igni-

tion electrode and the electrical connections of the flame

control device.

2 - Check that there is a minimum air supply pressure

equal to 80 mbar, and a minumim gas supply pressure

equal to 80 mbar by acting on the pressure stabilizers on

the line.

3 - Open the air interceprtion valve and regulate the regu-

lation valve to reach a mixture pressure of 10÷15 mbar on

the pressure outlet (pos. 01).

4 - Open the main gas valve

5 - Switch the burner on using the start buttion on the

flame control device. Slowly open the micrometric regula-

tion valve “B” during ignition (repeat this operation until

flame stability on the pilot burner is visually detected)

6 - Regulate the gas flow through the micrometric regula-

tion valve using the screw cap to obtain the maximum

detection value on the flame control device.

7 - To obtain an optimal flame adjust the gas flow in the

following conditions:

A - Excess air: a short blue flame disappears inside the

tube of the pilot burner (state of low detection).

B - Correct ratios: tense blue flame with a good detection

(40 to 60 mA).

C - Excess gas: a long blue / green flame that tends to

break (state of low detection).

11 - With the burner on, once you reach the adjustment

make sure there is a mixture pressure of 15 to 20 mbar

(pos. 01). Regulate the air control valve if necessary.

12 - Turn off the burner and check the restart, testing mul-

tiple consecutive ignitions.

esa-estro

START BUTTON 1

"B"

GAS INLET

AIR INLET

D3280I04

F3280I07F3280I06F3280I05

Excess of air Right ratio Excess of gas

Page 10: Burners - esapyronics.com · dents and environmental safeguarding. ... Equipment for industrial thermal process ... FLOW SCHEME FOR BURNER WITH INCORPORATED MIXER ...

PBC & PBST E3280 rev. 03 - 23/04/18

www.esapyronics.com 10

CAPACITY DIAGRAM

5

50

0.5 5 5 0

P86

P64

P42

1

10

100

0.1 1 10 100

P108

P32

G3280C01

Capacity (kW)

Mix

ture

pre

ssure

(m

bar)

GENERAL MAINTENANCE PLAN

Operation Type Advised time Notes

High voltage electrode connection O annual

Check integrity of outer plastic and oxidi

zation of internal connector and of the

electrode terminal

Ignition electrode and nozzle O annualReplace if the Kantal terminal is worn

or if the ceramic is damaged.

Stainless steel flexible hose E every six months

Check that there are no possible mixtu

re leaks from the connectors and flexi

ble hose

Burner settings O annualRepeat all the steps in the “IGNITION

AND SETTINGS” chapter on pg 9

O= Ordinary

E= Extraordinay

Page 11: Burners - esapyronics.com · dents and environmental safeguarding. ... Equipment for industrial thermal process ... FLOW SCHEME FOR BURNER WITH INCORPORATED MIXER ...

PBC & PBST E3280 rev. 03 - 23/04/18

www.esapyronics.com 11

1

2

4

THREADED CONNECTIONTO FLEXIBLE HOSE

ELECTRODE THREADEDCONNECTION

3

PILOT MAIN BODY

D3280I05

ORDINARY MAINTENANCE - BURNERS PBC & P108PBST-FR/X

IGNITION ELECTRODE REPLACEMENT

1 - Check that the burner control device power is off.

2 - Disconnect the HV cable, disconnecting the insula-

ting connector from the electrode (pos. 01).

3 - Unscrew the block screw (pos. 03) and extract the

pilot burner from the fastening connection (pos. 04).

4 - Unscrew the upper connection (pos. 02) and comple-

tely extract the electrode from the pilot burner.

5 - Insert the spare electrode and screw on the connec-

tion completely.

6 - Place the pilot burner in the correct position, tightening

the appropriate screw (pos. 03).

7 - Check that the insulator connector is properly connec-

ted.

Page 12: Burners - esapyronics.com · dents and environmental safeguarding. ... Equipment for industrial thermal process ... FLOW SCHEME FOR BURNER WITH INCORPORATED MIXER ...

PBC & PBST E3280 rev. 03 - 23/04/18

www.esapyronics.com 12

AIR CONNECTION

PILOT MAIN BODY01

02

03

04

GAS CONNECTION

D3280I06

EXTRAORDINARY MAINTENANCE - PBC-MX BURNER

IGNITION ELECTRODE REPLACEMENT

1 - Make sure the burner control device is not connected.

2 - Disconnect the HV cable, disconnecting the insulator

plug from the electrode (pos. 01).

3 - Unscrew the locking screw (pos. 03) and remove the

pilot burner from the bleed nipple (pos. 04).

4 - Unscrew the top (pos. 02) and pull the electrode out

from the pilot burner.

5 - Insert the electrode parts and screw on the connec-

tor.

6 - Correctly reposition the pilot burner by tightening the

screw (pos. 03).

7 - Check the correct connection of the insulating con-

nector (pos. 01).

Page 13: Burners - esapyronics.com · dents and environmental safeguarding. ... Equipment for industrial thermal process ... FLOW SCHEME FOR BURNER WITH INCORPORATED MIXER ...

PBC & PBST E3280 rev. 03 - 23/04/18

www.esapyronics.com 13

1

2

D3280I07

ORDINARY MAINTENANCE - BURNERS PBST

IGNITION ELECTRODE REPLACEMENT

1 - Check that the burner control device power is off.

2 - Disconnect the HV cable, disconnecting the insula-

ting connector from the electrode (pos. 01).

3 - Unscrew the spark-plug (pos. 02) and extract it from

the threaded seat.

4 - Insert the new spark-plug rescrewing it on until it

clicks into place.

5 - Check that the insulator connector is properly connec-

ted.

Page 14: Burners - esapyronics.com · dents and environmental safeguarding. ... Equipment for industrial thermal process ... FLOW SCHEME FOR BURNER WITH INCORPORATED MIXER ...

PBC & PBST E3280 rev. 03 - 23/04/18

www.esapyronics.com 14

OVERALL DIMENSIONS - P32PBC-FR/X

AIR INLET G3/8"

70,5±5

X 169

57

10

Ø3

/8"

G1

/2"

81

10

GAS INLETG3/8"

67 102

25

14

LG. M

IN 3

.. M

AX

60

0

BLAST TIP

32BTC-FR/X

20

1

D3280I22

Page 15: Burners - esapyronics.com · dents and environmental safeguarding. ... Equipment for industrial thermal process ... FLOW SCHEME FOR BURNER WITH INCORPORATED MIXER ...

PBC & PBST E3280 rev. 03 - 23/04/18

www.esapyronics.com 15

OVERALL DIMENSIONS - P42PBC-FR/X

42

G3

/4"

15

"X" By customer

13

26

74

5/1

04

10

52

Ø1

/2"

15

5

79

23

10

VE

NT

Lg

. Min

=3

00

/Ma

x=6

00

AIR INLET Rp 3/8"

VE

NT

73±5

GAS INLET Rp 1/4"

32

10

88

65

(Op

tio

na

l)1

72

10

58

Blast tip mod. 42BTC-FR/X

Extensible #exible hose

"2MM" gaspremixing group

D3280I08

Page 16: Burners - esapyronics.com · dents and environmental safeguarding. ... Equipment for industrial thermal process ... FLOW SCHEME FOR BURNER WITH INCORPORATED MIXER ...

PBC & PBST E3280 rev. 03 - 23/04/18

www.esapyronics.com 16

OVERALL DIMENSIONS - P64PBC-FR/X

Ø3

/4"

60"X" by customer

30

97

Lg

.Min

=3

00

/Ma

x=6

00

20

31

74

5/1

04

10

58

31

10

VENT

AIR INLET Rp 1/2"

21

5

VENT

17

26

5 (

Op

tio

na

l)6

0

29

10

GAS INLET Rp 3/8"

75±5

G 1

"

45

15 10

Blast tip mod. 64BTC-FR/X

Extensible #exible hose

"4MM" gaspremix group

D3280I09

Page 17: Burners - esapyronics.com · dents and environmental safeguarding. ... Equipment for industrial thermal process ... FLOW SCHEME FOR BURNER WITH INCORPORATED MIXER ...

PBC & PBST E3280 rev. 03 - 23/04/18

www.esapyronics.com 17

OVERALL DIMENSIONS - P86PBC-FR/X

Lg

.Min

=3

00

/Ma

x=6

00

5870 "X"= by customer

35

36

Ø1

"

14

75

0/1

05

10

VE

NT

34

10

AIR INLET Rp 3/4"

10

3

23

5V

EN

T

17

26

5 (

Op

tio

na

l)6

0

29

10

GAS INLET Rp 3/8"

75±5

G 1

.1/4

"

1020

42

Blast tip mod. 86BTC-FR/X

Extensible #exible hose

"6MM" gasmixing group

D3280I10

Page 18: Burners - esapyronics.com · dents and environmental safeguarding. ... Equipment for industrial thermal process ... FLOW SCHEME FOR BURNER WITH INCORPORATED MIXER ...

PBC & PBST E3280 rev. 03 - 23/04/18

www.esapyronics.com 18

OVERALL DIMENSIONS - P108PBC-FR/X

VENT

340±10

AIR INLET Rp 3/4"

Lg.M

in=

300/M

ax=

600

103

237±5

VENT

172

65 (

Optional)

60

297±10

GAS INLET Rp 3/8"

75±5

Ø1.1

/4"

"X" BY CUSTOMER 69 55

41

757/1

057±10

16

42

1020

BLAST TIP 108BTSA-FR

Extensible flexible hose

"6MM" gaspremixing group

D3280I11

Page 19: Burners - esapyronics.com · dents and environmental safeguarding. ... Equipment for industrial thermal process ... FLOW SCHEME FOR BURNER WITH INCORPORATED MIXER ...

PBC & PBST E3280 rev. 03 - 23/04/18

www.esapyronics.com 19

OVERALL DIMENSIONS - P42PBC-FR

G1

/2" 2

61

5

5857100

15

74

5/1

04

10

15

5

79

23

10

VE

NT

Lg

. Min

=3

00

/Ma

x=6

00

AIR INLET Rp 3/8"

VE

NT

73±5

GAS INLET Rp 1/4"

32

10

88

65

(O

pti

on

al)

17

2

Extensible #exible hose

Blast tip mod. 42BTC-FR

"2MM" gas

mixing group

D3280I12

Page 20: Burners - esapyronics.com · dents and environmental safeguarding. ... Equipment for industrial thermal process ... FLOW SCHEME FOR BURNER WITH INCORPORATED MIXER ...

PBC & PBST E3280 rev. 03 - 23/04/18

www.esapyronics.com 20

OVERALL DIMENSIONS - P64PBC-FR

Lg

.Min

=3

00

/Ma

x=6

00

G3

/4"

100 60 58

74

5/1

04

10

97

31

20

15

31

10

VE

NT

AIR INLET Rp 1/2"

21

5

VE

NT

17

26

5 (

Op

tio

na

l)6

0

29

10

GAS INLET Rp 3/8"

75±5

Blast tip mod. 64BTC-FR

Extensible #exible joint

"4MM" gas

mixing group

D3280I13

Page 21: Burners - esapyronics.com · dents and environmental safeguarding. ... Equipment for industrial thermal process ... FLOW SCHEME FOR BURNER WITH INCORPORATED MIXER ...

PBC & PBST E3280 rev. 03 - 23/04/18

www.esapyronics.com 21

OVERALL DIMENSIONS - P86PBC-FR

Lg

.Min

=3

00

/Ma

x=6

00

G1

"15

14

36

75

0/1

05

10

100 70 58

34

10

AIR INLET Rp 3/4"

10

3

23

5

VE

NT

17

26

5 (

Op

tio

na

l)6

0

29

10

GAS INLET Rp 3/8"

75±5

Blast tip mod. 86BTC-FR

Extensible #exible hose

"6MM" gasmixing group

VE

NT

D3280I14

Page 22: Burners - esapyronics.com · dents and environmental safeguarding. ... Equipment for industrial thermal process ... FLOW SCHEME FOR BURNER WITH INCORPORATED MIXER ...

PBC & PBST E3280 rev. 03 - 23/04/18

www.esapyronics.com 22

OVERALL DIMENSIONS - P108PBST-FR

VENT3

40

±1

0

AIR INLET Rp 3/4"

Lg

.Min

=3

00

/Ma

x=6

00

10

3

23

5

VENT

17

26

5 (

Op

tio

na

l)6

0

29

10

GAS INLET Rp 3/8"

75±5

R 1

.1/4

"

69 55

41

75

7/1

05

10

16

100

BLAST TIP mod. 108BTSA-FR

Extensible #exible hose

"6MM" gas

premixing group

D3280I15

Page 23: Burners - esapyronics.com · dents and environmental safeguarding. ... Equipment for industrial thermal process ... FLOW SCHEME FOR BURNER WITH INCORPORATED MIXER ...

PBC & PBST E3280 rev. 03 - 23/04/18

www.esapyronics.com 23

OVERALL DIMENSIONS - P64PBST

168±2G

3/4

"

86

31

100 20

74

5/1

04

10

15

31

10

VE

NT

Lg

.Min

=3

00

/Ma

x=6

00

AIR INLET Rp 1/2"

97

21

5

VE

NT

17

26

5 (

Op

tio

na

l)6

0

29

10

GAS INLET Rp 3/8"

75±5

BLAST TIP mod. 64BTSA

"4MM" gaspremixing group

Extensible !exible hose

D3280I16

Page 24: Burners - esapyronics.com · dents and environmental safeguarding. ... Equipment for industrial thermal process ... FLOW SCHEME FOR BURNER WITH INCORPORATED MIXER ...

PBC & PBST E3280 rev. 03 - 23/04/18

www.esapyronics.com 24

OVERALL DIMENSIONS - P86PBST

G 1

"

89

34

15

100

182

16

Lg

.Min

=3

00

/Ma

x=6

00

75

0/1

05

10

VE

NT3

40

±1

0

AIR INLET Rp 3/4"

10

3

23

5

VE

NT

17

26

5 (

Op

tio

na

l)6

0

29

10

GAS INLET Rp 3/8"

75±5

BLAST TIP mod. 86BTSA

Extensible #exible hose

"6MM" gaspremixing group

D3280I17

Page 25: Burners - esapyronics.com · dents and environmental safeguarding. ... Equipment for industrial thermal process ... FLOW SCHEME FOR BURNER WITH INCORPORATED MIXER ...

PBC & PBST E3280 rev. 03 - 23/04/18

www.esapyronics.com 25

OVERALL DIMENSIONS - P108PBST

VENT3

40

±1

0

AIR INLET Rp 3/4"

Lg

.Min

=3

00

/Ma

x=6

00

10

3

23

5

VENT

17

26

5 (

Op

tio

na

l)6

0

29

10

GAS INLET Rp 3/8"

75±5

69

41

75

7/1

05

10

16

BLAST TIP mod. 108BTSA

Extensible #exible hose

"6MM" gas

premixing group

G 1

.1/4

"

18

100

136

93

D3280I18

Page 26: Burners - esapyronics.com · dents and environmental safeguarding. ... Equipment for industrial thermal process ... FLOW SCHEME FOR BURNER WITH INCORPORATED MIXER ...

PBC & PBST E3280 rev. 03 - 23/04/18

www.esapyronics.com 26

OVERALL DIMENSIONS - P42PBC-MX-FR/X

AIR

IN

LE

T

Rp

3/8

"

PIL

OT

LE

NG

TH

= "

X"

42

10

46

5

53

GA

S I

NL

ET

R1

/4"

GAS THROTTLEVALVE

Ø1/2"

53

D3280I19

Page 27: Burners - esapyronics.com · dents and environmental safeguarding. ... Equipment for industrial thermal process ... FLOW SCHEME FOR BURNER WITH INCORPORATED MIXER ...

PBC & PBST E3280 rev. 03 - 23/04/18

www.esapyronics.com 27

OVERALL DIMENSIONS - P64PBC-MX-FR/X

GA

S I

NL

ET

R1

/4"

Ø3/4"

R 1"

"X

"

45

16

7

AIR

IN

LE

TR

p 1

/2"

58

26

55

68

D3280I20

Page 28: Burners - esapyronics.com · dents and environmental safeguarding. ... Equipment for industrial thermal process ... FLOW SCHEME FOR BURNER WITH INCORPORATED MIXER ...

PBC & PBST E3280 rev. 03 - 23/04/18

www.esapyronics.com 28

OVERALL DIMENSIONS - P86PBC-MX-FR/X

GA

S I

NL

ET

R3

/8"

42

PIL

OT

LE

NG

TH

= "

X"

AIR

IN

LE

TR

p 3

/4"

10

66

7

Ø 1"

58

D3280I21