This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Generated from the APACA Technical Specifications Template. For more details visit www.apaca.com.au
Bunbury Regional Entertainment Centre_Theatre_Techspecs08.doc
Page 2 of 16
STAGE
Brief Stage Description: Unraked stage with proscenium arch and false proscenium arch. Hardwood floor with Masonite cover. Screwing into stage permitted but larger holes must be authorised by Technical Manager. Stage crossover behind u/s fly line. Stage has bastard prompt and stage manager position either o/p or p/s.
Stage distributed load limit Not known Stage point load limit Not known Stage rake No
Stage Dimensions: Proscenium
Width 13.7m
Height 6.8m
Setting Line 880mm from d/s edge.
Distance From (SL = Setting Line, CL = Centre Line) SL to DS edge of apron 880mm SL to DS edge of Orchestra Lift/Pit 5380mm
SL to first fly line 600mm
SL to last upstage fly line 9.6m
SL to rear wall 11m
CL to OP wall (or obstruction) 13.7m
CL to PS wall (or obstruction) 10.2m
Stage to underside of grid 15m
Overhead obstructions 1st Gallery = 7.1m
2nd Gallery = 13.2m
Auditorium: Auditorium consists of stalls and 1 balcony level. Audio booth at rear of stalls comprising 18 seats.
Seating capacity with additional Orchestra lift/pit seating installed 792
Seating capacity without Orchestra lift/pit seating installed 721
Bunbury Regional Entertainment Centre_Theatre_Techspecs08.doc
Page 3 of 16
Orchestra Lift / Pit: Orchestra Pit
Motorised Orchestra Lift is operational. Serapid System. 1 person operation. Set positions for orchestra lift where lift at auditorium level is 0mm
Stage level at 1200mm above auditorium.
Orchestra pit level at 1800mm below auditorium.
Lift can be set at any height Yes
SWL of orchestra lift Not Known
Dimensions of the orchestra pit 14.4m x 4.4m Orchestra pit maximum capacity Approx. 50 chairs
Flying Facilities: Fly System
Single purchase counterweight handline system.
Fly System Details Operating Position P/S at stage level. Total number of Lines 46 Panorama Lines 1 fixed line o/p, 1 fixed line p/s Batten Drift 13.5m
Batten Pick-ups 4 pick ups. 2m from end of batten then 4m to next pick up. Batten Point Load Not Known
Batten W.L.L. 350kg
Cradle Capacity Refer to hanging plot for details. LX bars can be swung No Fly bars can be swung Yes
SEE HANGING PLOT FOR LINE ALLOCATIONS AND FURTHER INFO
Bunbury Regional Entertainment Centre_Theatre_Techspecs08.doc
Page 4 of 16
Hanging Plot: SL: Setting Line as indicated previously Line Type: SP = Single purchase, DP = Double purchase, MW = Motor Winch, HW = Hand Winch, HL = Handline W.L.L.: Maximum distributed load including bar weight
Line # Distance from SL
Line Type W.L.L Venue Allocation
Intended Use (hiring company use)
H.C. 1.195m HL 600kg Not Available for use Pelmet 1.430m HL 350kg Not Available for use
1 1.6m HL 350kg 2 1.79m HL 350kg LX-1 Lighting Bar 3 1.975m HL 350kg ¾ Bar 4 2.150m HL 350kg 5 2.335m HL 500kg Cinema Screen Not Available for use 6 2.515m HL 350kg #1 Legs 7 2.69m HL 350kg 8 2.98m HL 350kg 9 3.16m HL 350kg
Stage Covers: Style Tarquet Dimensions (6) Rolls, 12m x 2m Colour Two Sided, one side black, one side white.
Stage Traps: (1) Stage Trap located 2420mm 2420mm upstage of setting line.
Trap dimension is 1300mm x 1200mm. Use must be authorised by the Technical Manager.
Safety Curtain: Safety Curtain installed No
Safety Curtain must be unobstructed at all times N/A
Thickness of Fire Curtain N/A
Distance from setting line N/A Additional Requirements
N/A
Bunbury Regional Entertainment Centre_Theatre_Techspecs08.doc
Page 6 of 16
Loading Dock: Access
Truck access via car park off Victoria St. Truck must enter forwards and then reverse to loading dock. Loading Dock Height 700mm Door Dimensions 3m High
2.4m Wide
Restrictions / Obstructions At the loading dock roller door there is a 1 inch ridge acting as a water barrier.
Additional Rigging Notes Rigging points from grid, forestage, etc with load limits and access.
Staging Notes: All flown items must be rigged with rated equipment and is subject to approval by a venue representative.
Limited rigging gear in house. Droppers, shackles and flat lifters.
Access to galleries from P/S or O/P.
Bunbury Regional Entertainment Centre_Theatre_Techspecs08.doc
Page 7 of 16
LIGHTING
Positions: Stage LX Bars LX bars can be brailed up to 1m from standard position.
See hanging plot for standard LX bar locations
Orchestra Bar Setting Line to lighting bar N/A
FOH Bridge #1 Setting Line to lighting bar 6680mm @ 60 deg. Usable bar width 14m Notes 18 Selecon Pacific 23-50 Deg. Zoomspots as Standard.
FOH Bridge #2 Setting Line to lighting bar 12120mm @ 30 deg. Usable bar width 14m Notes 22 Selecon Pacific 12-28 Deg. Zoomspots as Standard.
Balcony Bar
Setting Line to lighting bar 14620mm @ 5 deg. Usable bar width 9m
FOH Perches (PS & OP) Setting Line to FOH Perch 2420mm @45-60 deg. Distances are to the highest downstage point of boom or perch. Maximum lanterns per perch 6 Selecon Acclaim Zoomspots 650w as Standard.
FOH Booms (PS & OP) Setting Line to FOH Boom 2420mm @ 5 deg. Distances are to the highest downstage point of boom or perch.
Maximum lanterns per boom Maximum 4 x Selecon Acclaim Zoomspots 650w.
FX Internal on Console Compression / Limiter / Gates
Internal on Console
Speakers: FOH Speakers
EV XI 1122. 2 per side. EV XI 2181 Single sub per side. EV XI 1122 Centre Cluster mounted side by side.
Foldback (6) EV SX300 on 4 sends powered by (2) EVP 2000. (4) EV ZX 500.
Bunbury Regional Entertainment Centre_Theatre_Techspecs08.doc
Page 11 of 16
Playback
Item Make Model Detail Total CD Player Denon C680 Pro CD Player 1 CD Player Marantz Cdr 631 CD Player and burner 1 Minidisk Sony MDS E12 Minidisk Recorder 1
Microphones
Make Model Detail / Accessories Use Total Shure SM58 Pop Guards and Clips. Vocal 5 Shure Beta SM 58 Vocal 2 Shure SM 57 Vocal/Inst. 4 AKG 451 Inst. 4 AKG D112 Kick 1 Shure Beta58A Radio Vocal 4 EV 391 Plate 2 EV RE90 Choral 4 Rode NTG-1 Vocal/Inst. 5
Accessories:
Item Model Detail / Accessories Total Microphone Stands Half Size Floor stand with boom 8 Microphone Stands Full Size Floor stand with boom 12
Location Quantity Numbering Detail Dip Traps 2 x f/back each 5
Cabling: Audio Cable
The theatre has a good stock of cable to accommodate the venues equipment.
Multicore (2) 8m Multi-core, 1 x 6 line+ 1 x 8 line.
Audio Notes: Control position not recommended for live mixing. Recommend using auditorium position with removal of 18 seats to accommodate console and operator (standard).
Bunbury Regional Entertainment Centre_Theatre_Techspecs08.doc
Page 12 of 16
AUDIO VISUAL
Projection Room: Dedicated room rear of auditorium.
Projectors:
Type Model Detail / Accessories Total Monee 35mm projector Cannot be relocated 1 NEC Data Projector LT 260 Can be moved 1 NEC Data Projector NP2000 Can be moved. Wide angle lens. 1
Screens: Projection Screen
Front projection Cinema screen permanently rigged from line 5.
Screen dimensions 10m x 6m with tab track for all formats.
Additional Screens N/A
AV Playback Equipment:
Item Model Detail / Accessories Total JVC DVD XV-N422 Single DVD player with record functions. 1 LG DVD DZ9811P Single DVD Player 1
Projector Rigging Points: Projector has a mounting assembly and can be rigged from any horizontal lighting bar.
Cabling: The theatre has access (hire) to full stock of coaxial and RCA/VGA cabling.
Audio Visual Notes: We also have dedicated cinema audio system. 3 x XEQ 504A Crossover and 2 x JBL Subs.
Bunbury Regional Entertainment Centre_Theatre_Techspecs08.doc
Page 13 of 16
BACKSTAGE
Communications: Stage Managers Desk
Stage managers desk can be located either O/P or P/S. Desk can be fitted with CD player and 8 channel audio desk patched through the main system.
Talkback Master Unit Located o/p d/s corner. Two common loops. Total sub stations 6
Total headsets 8
Radio Units In-house Nil Talkback patching located at: FOH Audio
Paging / Show relay Paging master unit is located in O/P D/S corner. Paging is to all dressing rooms, rehearsal room and green room. Each area has individual volume control.
Stage Monitor Stage monitors are located in O/P D/S corner, rehearsal room, green room and foyer. Camera is located on centre of balcony bar.
Q Light System In house Q light system available No
Laundry / Wardrobe: Washing Machines 1 Dryers 1 Drying rooms No Iron / ironing board 1
Clothes racks 4
Bunbury Regional Entertainment Centre_Theatre_Techspecs08.doc
Page 14 of 16
Production Facilities: Production Desk
Production Desk is folding table set-up in middle of stalls. Table accommodates 2 people. DMX and Talkback are run from P/S D/S corner.
Production Office No
Phone Access to phone in Technical Managers office.
Fax Fax available on request from front office.
Access to phone for internet access Phone point for internet from inside stage door entrance. Ethernet extension available.
Greenroom: Tea / Coffee facilities Yes
Fridge / freezer No
Microwave Yes Running water Yes
Stage Door: Access
Stage door is located next to loading dock. Access controlled at all times by senior technician.
ADDITIONAL FACILITIES & INFORMATION
Orchestral: Steinway ‘D’ Series Concert Grand available. Tuning to be arranged prior to arrival.
Yamaha upright available.
30 Music stands.
30 Padded grey chairs for on-stage seating.
(5) 10 amp GPO outlets all on individual circuits.
Rehearsal Space: Rehearsal Room available. Approx. 12m x 6m. Full mirrored wall for dance rehearsal.
Portable CD Player available on request.
Hire Stock; We have a comprehensive range of theatre lamps available for hire. Including wide and narrow profiles, 1k + 2k Fresnels.
Bunbury Regional Entertainment Centre_Theatre_Techspecs08.doc
Page 15 of 16
VENUE:
Venue Contacts: Venue Address Cnr. Blair and Symmons St. Bunbury. Venue Postal Address P.O. Box 1983 Bunbury 6231
Staff Contacts: Technical Manager Paul Parkes
Mobile 0427 387 502 Email Address [email protected] Phone Number 08-9791 1133
Head of Staging Matt Fletcher Mobile 0417 907 973 Email Address [email protected] Phone Number 08-9791 1133
Head of Audio Geoff Dent Mobile 0438 709 062 Email Address [email protected] Phone Number 08-9791 1133
Administration Matara Merrit Phone Number 08-9792 3111 Email Address [email protected] Fax Number 08-9792 3122
Box Office Peta Bazzo Phone Number 08-9791 1133 Email Address [email protected] Fax Number 08-9792 3122
Stage Door Phone Number N/A
Stage Phone Number N/A
Venue Plans: Venue Plan Available
Yes. Hard copy at 1:50 can be mailed. A DWG file can be e-mailed on request. Plan is available for download from APACA website.
Venue Section Available Yes. Hard copy at 1:50 can be mailed. A DWG file can be e-mailed on request.
Bunbury Regional Entertainment Centre_Theatre_Techspecs08.doc
Page 16 of 16
Venue Information: The venue is centrally located in Bunbury CBD. Accommodation, hotels, take away food and restaurants are all within 2 minutes walk of the centre. A core staff of 7 run the centre which is council funded. The Bunbury Regional Entertainment Centre operates 1 performance space. We also run the venue as a Cinema and program 2 international film festivals per year.