Page 1: Building Simulation. BMEABMEA uilding odeling nergy nalysis.

BuildingSimulation

Page 2: Building Simulation. BMEABMEA uilding odeling nergy nalysis.

BMEA

uildingodelingnergynalysis

Page 3: Building Simulation. BMEABMEA uilding odeling nergy nalysis.

What is BMEA?Models a building

Existing or proposed

• Shell and Core• Lighting• Equipment Load• Occupancy• Internal Mass

• Environmental Systems• Schedules• Climate• Utility Service

Page 4: Building Simulation. BMEABMEA uilding odeling nergy nalysis.

Shell and Core• Exterior walls Structure and finish• Windows Glass, frame, size• Doors Type and size• Roof Type, material, overhang• Shading Natural and structural• Insulation Type and R-value• Floors Floor covering and insulation• Ceiling Construction and insulation• Interior walls Construction and arrangement• Interior mass Furniture

Page 5: Building Simulation. BMEABMEA uilding odeling nergy nalysis.

Lighting

• Bulb

• Fixture

• PlacementRecessed, surface, or hanging

Open or enclosed

Page 6: Building Simulation. BMEABMEA uilding odeling nergy nalysis.

Equipment Load• Office Equipment• Infrastructure• Industrial Process

Load Breakdown

• Utility Total building load• Thermostat Loads in zones• Meter Loads in non-HVAC spaces

Page 7: Building Simulation. BMEABMEA uilding odeling nergy nalysis.

Environmental Systems• Built-up

• Package

• Split system• Air & water• Geothermal• Solar

• Process HVAC

• VFD Pumps and fans

• T-stat warm-up and setback

• Exhaust fans

• Zoning

• Domestic hot water

Page 8: Building Simulation. BMEABMEA uilding odeling nergy nalysis.

Schedules• Daily, weekly, and annual

• Weekends and holidays

• TypesOccupancyLightingEquipmentEnvironmental

Systems

Page 9: Building Simulation. BMEABMEA uilding odeling nergy nalysis.

Climate

• Model anywhere in the U.S.

• Seasonal

• Day and night

• 30-year average

Page 10: Building Simulation. BMEABMEA uilding odeling nergy nalysis.

Utility Service

• Electric and gas

• Anywhere in the U.S.

• Basic and demand charges

• Block and ratchet charges

• Rate analysis

Page 11: Building Simulation. BMEABMEA uilding odeling nergy nalysis.

What can BMEA do for me?

• Evaluate options

• Optimize strategies

• Compare costsSimple paybackLife cycleReturn-on-investment

• Evaluate energy usageRate reductionsRebatesTax credits

Reduce energy costs

Page 12: Building Simulation. BMEABMEA uilding odeling nergy nalysis.

Caveats

• Clearly defined objectives

• Cost-effective modifications

• Energy-usage figures are relative

• Cost vs. Value

Page 13: Building Simulation. BMEABMEA uilding odeling nergy nalysis.
Page 14: Building Simulation. BMEABMEA uilding odeling nergy nalysis.

Two-Story Office BuildingPortland, OR

Structure - 25,000 sq. ft.

6” concrete slab

Ext. Wall – 2 x 6 metal frame

Fiberboard sheathing

R-19 batt

Built-up roof

3” polyurethane R-18

Page 15: Building Simulation. BMEABMEA uilding odeling nergy nalysis.

Two-Story Office Building

Windows - ¼” Double-clear on North¼” Double-bronze all other

Doors - ¼” clear glass w/ 3” Al frame

Int. Wall - 2” x 4” metal frameDrywall

R-13 batt

Page 16: Building Simulation. BMEABMEA uilding odeling nergy nalysis.

Two-Story Office Building

Ceiling - Lay-in acoustic tile

No ceiling insulation

Floors- Carpet w/ fiber pad

12 foot floor-to-floor

9 foot floor-to-ceiling

Page 17: Building Simulation. BMEABMEA uilding odeling nergy nalysis.

Two-Story Office Building

Lighting - 2 x 4 concealed troffer

T8 ES fluorescent

High-efficiency magnetic ballast

Loads - 2 watt/sq. ft.

No exterior loads

Page 18: Building Simulation. BMEABMEA uilding odeling nergy nalysis.

Two-Story Office Building

Occupancy - 8 am – 5 pm

Mon – Fri

Major US holidays

90% while open

Page 19: Building Simulation. BMEABMEA uilding odeling nergy nalysis.

Two-Story Office Building

Environmental Systems

AHU Supply and return fansEconomizerConstant speed+1 hour open/closeChill water coil55F discharge air for cooling

Page 20: Building Simulation. BMEABMEA uilding odeling nergy nalysis.

Two-Story Office Building

VAV Core and perimeter zones74 / 72 Occ. – 82 / 64 Unocc.Plenum returnHot water heating coil95F discharge air for heat

Page 21: Building Simulation. BMEABMEA uilding odeling nergy nalysis.

Two-Story Office Building

Chiller - Electric recip. hermetic

Air-cooled condenser

44F supply water

Boiler - Natural gas

80% efficiency rating

180F discharge water

Page 22: Building Simulation. BMEABMEA uilding odeling nergy nalysis.

Two-Story Office Building

Domestic Hot Water Natural gas

88-gallon tank

135F discharge

Pumps Constant speed

Standard motor

Page 23: Building Simulation. BMEABMEA uilding odeling nergy nalysis.

Two-Story Office Building

Electricity PGE Schedule 32Small Non-Residential0.085/kW

Natural gas NW Natural Schedule 31Non-Residential0.95/Therm (100,000 Btu)

Page 24: Building Simulation. BMEABMEA uilding odeling nergy nalysis.

Running the SimulationBaseline

Electricity 146,650 kW $12,465

Natural gas 5,252 Therms

$4,935

Energy Total $17,400

Page 25: Building Simulation. BMEABMEA uilding odeling nergy nalysis.

Running the SimulationRaise Cooling Set Point

Raise cooling set point from 74F to 75F

Reduce annual electricity consumption

2250 kW annually

$190 per year

1.1% of annual energy cost

Page 26: Building Simulation. BMEABMEA uilding odeling nergy nalysis.

Running the SimulationReplacing the Boiler

Install 90% efficiency boiler

Reduce natural gas consumption

550 Therms annually

$525 per year

3.0% of annual energy cost

Oregon Business Energy Tax Credit

35% of project cost over five years

Page 27: Building Simulation. BMEABMEA uilding odeling nergy nalysis.

Running the Simulation Synergy

Raise the temperature and replace the boiler

2250kW $190 annually

737 Therms$695 annually

$885 in energy savings

5.1% of total energy bill

Page 28: Building Simulation. BMEABMEA uilding odeling nergy nalysis.

Building Modeling Energy Analysis

• Simulate an existing or proposed building

• Model a wide range of building elementsStructuralEnvironmental

• Flexible and adaptable

• Cost-effective analysis