BUILDING LOADS / DESCRIPTION:

WIDTH:

ROOF PITCH:

THIS STRUCTURE IS DESIGNED UTILIZING THE LOADS INDICATEDAND APPLIED AS REQUIRED BY :

THE CONTRACTOR / BUILDER IS TO CONFIRM THAT THESE LOADS COMPLYWITH THE REQUIREMENTS OF THE LOCAL BUILDING DEPARTMENT.

ROOF DEAD LOAD:

COLLATERAL LOAD:

ROOF LIVE LOAD:

GROUND SNOW LOAD: (Pg)

ROOF SNOW LOAD: (Pf)

BASIC WIND SPEED:

SEISMIC COEFFICIENT:

IMPORTANCE FACTORS:

PSF (ROOF PANELS & PURLINS)

PSF

PSF

PSF

PSF

MPH

2.28

1.0

20.0

42.85

30.0

115

0.875

LENGTH: HEIGHT:50 60 18 / 18

ROOF PANELS:

WALL PANELS:

TRIM COLORS:

LINER PANEL:

COLOR:

COLOR:

GABLE:

EAVE:

CORNER:

Sandstone Beige

Sandstone Beige

Brown

Brown

Brown

Brown

6. BUILDER / CONTRACTOR RESPONSIBILITIES

GRADE 55GRADE 55GRADE 55GRADE EHSGRADE 50GRADE BGRADE 80GRADE 50

GRADE 5A325

A529 OR A572 OR A1011SSA529A1011SSA475A992A500A653 OR A792A653 OR A792

GRADE 5A325

ASTM DESIGNATION

ADDRESS:CUSTOMER NAME:

1. MATERIALS

CUSTOMER INFORMATION

PROJECT NAME: HANGAR PROJECT LOCATION:

GENERAL NOTES

GUTTER:

DOOR & WINDOW:

1.0:12

2. DESIGN

5. STRUCTURAL PRIMER

4. A325 BOLT TIGHTENING REQUIREMENTS

3. HIGH STRENGTH BOLT CONNECTIONS:

Brown

Brown

BASE (OPTIONAL):

8" JAMB/HEAD:

DOWNSPOUTS:

SOFFIT PANEL:

A. ALL STRUCTURAL STEEL SECTIONS AND WELDEDPLATE MEMBER ARE DESIGNED IN ACCORDANCE WITH THE AISC"SPECIFICATIONS FOR THE DESIGN, FABRICATING AND ERECTION OF STRUCTURAL STEEL BUILDING". ALLOWABLE STRESS DESIGN

LATEST EDITION.

B. ALL COLD FORMED MEMBERS ARE DESIGNED IN ACCORDANCE WITHAISI "SPECIFICATIONS FOR DESIGN OF COLD FORMED STEELSTRUCTURAL MEMBERS" LATEST EDITION.

C. ALL WELDING OF STRUCTURAL STEEL IS BASED ON AWSD1.1"STRUCTURAL WELDING CODE" LATEST EDITION.

ALL STRUCTURAL MEMBERS WILL BE GIVEN ONE COAT OF MANUFACTURER'SSTANDARD RUST-INHIBITIVE PRIMER MEETING THE PERFORMANCE REQUIREMENTS OF TT-P-6645. THIS IS NOT A FINISH COAT AND IS NOT INTENDED FOR PROLONGEDEXPOSURE TO THE ELEMENTS. REFERENCE AISC 360-05, CODE OF STANDARDPRACTICE SECTION 6.5.1-6.5.4.

ALL HIGH STRENGTH BOLTED CONNECTIONS ARE SUBJECT TO AXIAL

ALL HIGH STRENGTH BOLTS ARE TYPE ASTM A325 AND ARE TO BE INSTALLED

TENSION AND OR SLIP CRITICAL. AS SUCH THE BOLTS MUST BE FULLY

ACCORDING TO THE "SNUG-TIGHT" CONDITIONS AS DEFINED BY THE,

PRE-TENSIONED AND INSPECTED IN ACCORDANCE WITH THE LATEST

(REFERENCE STEEL CONSTRUCTION AISC MANUAL - THIRTEENTH EDITION)RCSC SPECIFICATION FOR STRUCTURAL JOINTS USING A325 OR A490 BOLTS, SECTION 6

RCSC SPECIFICATION FOR STRUCTURAL JOINTS USING A325 OR A490 BOLTS,

EDITION OF THE AISC SPECIFICATION FOR STRUCTURAL JOINTS USING

2004 EDITION - SECTION 6.1, UNLESS NOTED OTHERWISE.

ASTM A325 BOLTS AND THE APPLICABLE BUILDING CODE. WASHERS ARE

ALSO, NOTE THAT BOLTS IN STANDARD HOLES DO NOT REQUIRE WASHERS PER THE,

NOT REQUIRED WHEN THE "TURN OF THE NUT" TIGHTENING PROCEDURE IS USED. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE PROPER BOLT TIGHTNESS.

STRUCTURAL STEEL PLATEFLANGE MATERIAL COLD FORMED LIGHT GAUGE SHAPES STRUCTURAL CABLES HOT ROLLED MILL SHAPE HOLLOW STRUCTURAL SECTIONS PBR36 ROOF AND WALL PANELS STANDING SEAM ROOF

BOLTS BOLTS

/ 1.0:12

SEISMIC:

SNOW LOAD:

WIND LOAD: 1.00

1.00

1.00

LEFT :

RIGHT:

FRONT:

BACK :

ROOF :

GABLE EXT:

EAVE EXT:

CANOPY:

THE DESIGN OF THE ANCHOR BOLT EMBEDDMENT

R & M STEEL COMPANY STANDARD

DESIGN ENGINEER. THE LENGTH PROVIDED BY R & M

ADJUSTED ACCORDING TO THE FOUNDATION DESIGN.STEEL IS AN ESTIMATED LENGTH AND SHOULD BE

LENGTH IS THE RESPONSIBILITY OF THE FOUNDATION

PRODUCT SPECIFICATIONS APPLY ANDR & M STEEL COMPANY DESIGN, FABRICATION, QUALITY CONTROL STANDARDS AND TOLERANCE WILL GOVERN. IN CASE OF DISCREPANCIES BETWEEN R & M STEEL COMPANY'S PLANS AND PLANS FOR OTHER TRADES R & M STEEL PLANS SHALL GOVERN. (SECTION 3.3 AISC CODE OF STANDARD PRACTICES, LATEST EDITION)

IT IS THE RESPONSIBILITY OF THE BUILDER / CONTRACTOR TO OBTAIN APPROPRIATE APPROVALS AND NECESSARY PERMITS FROM CITY, COUNTY, STATE OR FEDERAL AGENCIES AS REQUIRED.

APPROVAL OF R & M STEEL COMPANY'S DRAWINGS CONSTITUTES THE BUILDER / CONTRACTOR'S ACCEPTANCE OF R & M STEEL COMPANY'S INTERPRETATION OF THE PURCHASE ORDER. (SECTION 4.2.1 AISC CODE OF STANDARD PRACTICES, LATEST EDITION)

THE BUILDER / CONTRACTOR OR A/E FIRM IS RESPONSIBLE FOR THE OVERALL PROJECT. ALL INTERFACE AND COMPATIBILITY CONCERNING ANY MATERIAL NOT FURNISHED BY R & M STEEL COMPANY ARE TO BE CONSIDERED AND COORDINATED BY THE BUILDER / CONTRACTOR OR A/E FIRM UNLESS SPECIFIC DESIGN CRITERIA CONCERNING THIS INTERFACE BETWEEN MATERIALS IS FURNISHED AS PART OF THE PURCHASE ORDER. R & M STEEL COMPANY ASSUMPTIONS WILL GOVERN.

THE BUILDER / CONTRACTORS RESPONSIBLE FOR SETTING OF ANCHOR BOLTS AND ERECTION OF STEEL BUILDING COMPONENTS IN ACCORDANCE WITH R & M STEEL COMPANY'S BUILDING "FOR CONSTRUCTION" DRAWINGS. TEMPORARY SUPPORTS OR BRACING REQUIRED FOR THE BUILDING ERECTION WILL BE THE RESPONSIBILITY OF THE ERECTOR TO DETERMINE, FURNISH AND INSTALL. (SECTION 7.9.1 AISC CODE OF STANDARD PRACTICES, LATEST EDITION)

1=Ct1=I

PSF=PgPSF

40.5

42.8530.0=Pf

PSF=UNBALANCED LOAD

1=CePf = 0.7 Ce Ct I Pg

R & M STEEL COMPANY

Caldwell, Idaho 83606

DRAWING NUMBER

REVISION

P.O. Box 580

208-454-1800 Fax 208-454-1801

JOB LOCATIONSCALE:

DRAWN BY

OF

DSite Class:0.21Mapped Response (1 sec.), S1:

65650.1748

0.28

0.4127

0.2827

0.58

0.87

Equivalent Lateral

0.71

Wind Bent Deflection Limit (Seis):Rigid Frame Deflection Limit (Seis):Approx. Period (Brace), Ta:

Design Response (1 sec.), Sd1:

Max. Design Response (1 sec.), Sm1:

Approx. Period (Moment), Ta:

Design Response (Short), Sds:

Max. Design Response (Short), Sms:

Analysis Procedure Used:

Mapped Response (Short), Ss:

1.9840

OCBF, OMF

1.00

1.3000

1.3000

=

=

Rho

Rho

0.18

0.18

0.18

3.00002.0000

2.0000

0.18

=

=

=

==

=

=

Cs

Cs

Cs

OmegaOmega

Omega

Cs

3.2500

3.25003.2500

3.2500

3.2500

=

==

=

=

R

RR

R

R

Rigid Frames:

End Plates, Frame:Endwall Bracing:

3.61 (k)=Transverse Force, V 3.57 (k)=Longitudinal Force, V

Total Base Shear:

Sidewall Bracing:

Roof Bracing:

Site Coeff (1 sec.), Fv:

Basic Seismic-Force-Resisting Systems:

Seismic Importance Factor:

1.2320

D

II - Normal

Seismic Forces:

Site Coeff (Short), Fa:

Seismic Design Category, SDC:

Occupancy Category:

DES_CALC:

FORCE:

RESULT:

INPUT:

EARTHQUAKE DESIGN DATA:

IBC 12

Page 3: BUILDING LOADS / DESCRIPTION...of structural steel building". allowable stress design latest edition. b.all cold formed members are designed in accordance with aisi "specifications

R & M STEEL COMPANY

Caldwell, Idaho 83606

DRAWING NUMBER

REVISION

P.O. Box 580

208-454-1800 Fax 208-454-1801

JOB LOCATION

2/ 5/16DATE:

SCALE:

DRAWN BY

OF

1=Ct1=I

PSF=PgPSF

40.5

42.8530.0=Pf

PSF=UNBALANCED LOAD

1=CePf = 0.7 Ce Ct I Pg

Page 4: BUILDING LOADS / DESCRIPTION...of structural steel building". allowable stress design latest edition. b.all cold formed members are designed in accordance with aisi "specifications

R & M STEEL COMPANY

Caldwell, Idaho 83606

DRAWING NUMBER

REVISION

P.O. Box 580

208-454-1800 Fax 208-454-1801

JOB LOCATIONSCALE:

DRAWN BY

CJH

OF

A

A

B

C

C

B

D E E

D E E

1'-2"

1'-2"

47'-8"

(Hold

This

Dim

ensio

n)

1 42 3

20'-0" 20'-0" 20'-0"

ANCHOR BOLT PLANNOTE: All Base Plates @ 100'-0" (U.N.)

1 4

2 320'-0" 20'-0" 20'-0"

60'-0" OUT-TO-OUT OF STEEL

FRAME LINEDIMENSIONS

A

F

B

E

2'-3"

45'-6"

2'-3"

50'-0"

OU

T-T

O-O

UT

OF

ST

EE

L

A

F

C

D

14'-4"

20'-0"

14'-4"

8"

8"

11" 19'-1"

11" 1'-1" 3'-0" 15'-0"

1 1

/2"

1 1

/2"

1 1/2" 1 1/2"

1 1

/2"

1 1

/2"

1 1

/2"

1 1

/ 2"

1 1

/2"

1 1

/ 2"

1 1

/2"

1 1

/2"

1 1/2"1 1/2"

1 1/2"1 1/2"

2"

2"

2"

2"

2"

2"

2"

2"

4"

4"

1 1/2"

1 1/2"

X-Bracing

X-B

racin

g

X-Bracing

1 1/2"3"

See P

lan

6"

6 1/4"

1 1

/2"

1 1

/2"

1 1

/2"

3"

EW

DETAIL A

Dia= 3/4"

8"

6 1

/2"

8"

2"

2"

2 1

/2"

3"

EW

SW

DETAIL B

Dia= 3/4"

See P

lan

6 1

/2"

8"

2"

2"

2 1

/2"

3"

EW

DETAIL C

Dia= 3/4"

11"

6"

8 1

/2"

1 1/2" 1 1/2"

2"

4"

8"

SW

EW

DETAIL D

Dia= 3/4"

See Plan

6"

8 1

/2"

1 1/2" 1 1/2"

2"

4"

8"

SW

DETAIL E

Dia= 3/4"

HOOK BAR OR TIE ROD (AS REQ'D)

0'-2" PROJECTION MIN.

OUT OF STEEL

OUT OF CONCRETE

GRADE

ANCHOR BOLTCONCRETE DETAIL

12"TO ASSURE PROPER DOORSEAL EXTEND CONCRETE

ADDITIONAL 12" PASTOUT OF CONCRETE LINE

@ GRID

EXTEND CONCRETE 12"OUTSIDE OF BUILDING.

SLOPE 1/4" PER FOOTMINIMUM FOR DRAINAGE

BI-FOLD DOOR SEAL

BI-FOLD DOOR

STEELLINE

OUT OFCONCRETELINE

1

BI-FOLD DOOR DETAIL

Page 5: BUILDING LOADS / DESCRIPTION...of structural steel building". allowable stress design latest edition. b.all cold formed members are designed in accordance with aisi "specifications

1"12

1"12

SP

-1

SP

-2

SP

-1

FB6D(1) FB2D(1) FB3D(1) FB5D(1) FB8D(1) FB8D(1) FB5D(1) FB3D(1) FB2D(1) FB6D(1)

FB

4D

(1)

FB

7D

(1)

FB

4D

(1)

FB

7D

(1)

RF

1-1

RF1-2 RF1-3

RF

1-4

15'-6 1

/4"

Cle

ara

nce +

/-

15'-6 1

/4"

Cle

ara

nce +

/-

17'-4 1

/2"

Cle

ara

nce +

/-

2'-1 7/8" 2'-1 7/8"

44'-4 3/16"Clearance +/-

F A

50'-0" OUT-TO-OUT OF STEEL

RIGID FRAME ELEVATION: FRAME LINE 1

8" 8"

3'-4"

4'-0"

5'-8"

5'-0"

18'-0"

3'-4"

4'-0"

5'-8"

5'-0"

18'-0"

5 @ 4'-9 13/16"

1'-0" 1'-0"5 @ 4'-9 13/16"

8"

8"

26 Ga. PBR, Sandstone Beige

25'-5"

8"8 11/16" 25'-5"8 11/16"

8"

RCAP

R & M STEEL COMPANY

Caldwell, Idaho 83606

DRAWING NUMBER

REVISION

P.O. Box 580

208-454-1800 Fax 208-454-1801

JOB LOCATIONSCALE:

DRAWN BY

OF

MEMBER TABLE

MarkWeb DepthStart/End

Web PlateThick Length

Outside FlangeW x Thk x Length

Inside FlangeW x Thk x Length

RF1-1, RF1-4 8.0/25.4 0.150 209.8 6 x 1/4" x 207.96 x 1/4" x 31.5

6 x 1/4" x 183.3

RF1-2 24.0/12.0 0.150 96.012.0/23.9 0.150 172.0

6 x 1/4" x 268.1 6 x 1/4" x 96.76 x 1/4" x 170.46 x 1/4" x 170.46 x 1/4" x 96.7

6 x 1/4" x 268.1RF1-3 23.9/12.0 0.150 172.012.0/24.0 0.150 96.0

SPLICE PLATE & BOLT TABLE

QtyMark Top Bot Int Type Dia Length Width Thick Length

SP-1 4 4 0 A325 0.750 2.00 6" 1/2" 2'-6 13/16"SP-2 4 4 0 A325 0.750 2.00 6" 1/2" 2'-6 11/16"

FLANGE BRACES: Both Sides(U.N.)FBxxD(1)D - L2x2x14

Page 6: BUILDING LOADS / DESCRIPTION...of structural steel building". allowable stress design latest edition. b.all cold formed members are designed in accordance with aisi "specifications

1"12

1"12

SP

-1

SP

-2

SP

-1

FB6D

FB3DFB8D FB8D

FB3D

FB6D

FB

4D

FB

7D

FB

4D

FB

7D

RF

2-1

RF2-2 RF2-2

RF

2-1

15'-6 1

/4"

Cle

ara

nce +

/-

15'-6 1

/4"

Cle

ara

nce +

/-

17'-4 1

/2"

Cle

ara

nce +

/-

2'-1 7/8" 2'-1 7/8"

44'-4 3/16"Clearance +/-

F A

50'-0" OUT-TO-OUT OF STEEL

RIGID FRAME ELEVATION: FRAME LINE 2 3

8" 8"

3'-4"

4'-0"

5'-8"

5'-0"

18'-0"

3'-4"

4'-0"

5'-8"

5'-0"

18'-0"

5 @ 4'-9 13/16"

1'-0" 1'-0"

5 @ 4'-9 13/16"

8"

8"

26 Ga. PBR, Sandstone Beige

25'-5"

8"8 11/16" 25'-5"8 11/16"

8"

RCAP

R & M STEEL COMPANY

Caldwell, Idaho 83606

DRAWING NUMBER

REVISION

P.O. Box 580

208-454-1800 Fax 208-454-1801

JOB LOCATIONSCALE:

DRAWN BY

OF

MEMBER TABLE

MarkWeb DepthStart/End

Web PlateThick Length

Outside FlangeW x Thk x Length

Inside FlangeW x Thk x Length

RF2-1 8.0/25.4 0.150 209.8 6 x 1/4" x 207.96 x 1/4" x 31.5

6 x 1/4" x 183.3

RF2-2 24.0/12.0 0.150 96.012.0/23.9 0.150 172.0

6 x 1/4" x 268.1 6 x 1/4" x 96.76 x 1/4" x 170.4

SPLICE PLATE & BOLT TABLE

QtyMark Top Bot Int Type Dia Length Width Thick Length

SP-1 4 4 0 A325 0.750 2.00 6" 1/2" 2'-6 13/16"SP-2 4 4 0 A325 0.750 2.00 6" 1/2" 2'-6 11/16"

FLANGE BRACES: Both Sides(U.N.)FBxxD(1)D - L2x2x14

Page 7: BUILDING LOADS / DESCRIPTION...of structural steel building". allowable stress design latest edition. b.all cold formed members are designed in accordance with aisi "specifications

A9

STEEL LINERIGID FRAME

RAFTER

TEK SCREW@ EA. PURLIN

RA20

ROOFPURLIN

FLANGEBRACE

ROOF PURLIN TO ENDWALL RIGID FRAME

4"

2"

CL11"

(2)BOLTS1/2" x 1" (TYP.)

3/30/09 WD

4/2/09 WD

(2) BOLTS1/2" x 1" (TYP)

EW GIRT

GIRT CLIP

JAMB COLUMN

C7JAMB COLUMN TOENDWALL GIRT

3/26/09 JMS 4/ 9/09 WD

R & M STEEL COMPANY

Caldwell, Idaho 83606

DRAWING NUMBER

REVISION

P.O. Box 580

208-454-1800 Fax 208-454-1801

JOB LOCATIONSCALE:

DRAWN BY

OF

BOLTS1/2" x 1" (TYP)

FIELD FIT

SW GIRT

D16

FLANGE BRACE(AS REQ'D.)

RIGIDFRAME

COLUMN

EW GIRT

CORNER COLUMN TO GIRTS

ENDWALL COLUMNTO ENDWALL RAFTER

B7

(4) BOLTS1/2" x 1" (TYP)

ENDWALL COLUMN

ENDWALL RAFTER

D1

(6) BOLTS1/2" x 1" (TYP)

CORNERCOLUMN TO WALL GIRTS

CA52

L 4 x 2 x 7-3/8 w/(2) #12 x 1" TEKS

SA

SWC-N

CORNERCOLUMN

ENDWALLGIRT

SIDEWALLGIRT

BOLTS1/2" x 1" (TYP)

DOUBLE 'C' ENDWALL COLUMN TO GIRTS

DOUBLE 'C'ENDWALL COLUMN

CA52

COLUMN ASSEMBLY

BOLTS1/2" x 1" (TYP)

CA52

ENDWALLGIRT

C2

ENDWALLGIRT

(4) BOLTS1/2" x 1" (TYP)

EW GIRT

EW GIRT

C6

GIRT CLIP

HINGE BRACKET

HINGE BRACKET TO ENDWALL GIRT

ENDWALL 'C' COLUMN

(4) BOLTS1/2" x 1" (TYP)

E1BASE PLATE FOR EW COLUMN

ANCHOR BOLT

(2) SP-CA3

(4) BOLTS1/2" x 1" (TYP)

E2

EW COLUMN(DOUBLE 'C')

BASE PLATE FOR EW COLUMN

ANCHOR BOLT

(2) SP-CA3

B2 WALL GIRT BRIDGING

WALL GIRT

TEKSCREW

1" x 1" x .075"BRIDGING ANGLEAS SHOWN

B4

ENDWALLRAFTER

ENDWALLCOLUMN

BOLTS (TYP) (4) 1/2" x 1"

ENDWALL RAFTER TO COLUMN

LOCATE CLIP BETWEEN"C" COLUMN WEBS

TEK SCREW@ EA. PURLIN

PURLIN

ENDWALLRAFTER 1/2"

CLEARANCE

STEEL LINE

RA20

4"

2"

A3

FLANGEBRACE

ROOF PURLIN TO ENDWALL RAFTER

CL4"

(2) BOLTS1/2" x 1" (TYP)

B35

JAMB COLUMN

FRAME COLUMN

PURLIN CLIP

PURLIN

RAKE ANGLE

A325 BOLTS(2) 3/4" x 2"

JAMB COLUMN TO FRAMECOLUMN (W / 11" SETBACK)

Page 8: BUILDING LOADS / DESCRIPTION...of structural steel building". allowable stress design latest edition. b.all cold formed members are designed in accordance with aisi "specifications

R & M STEEL COMPANY

Caldwell, Idaho 83606

DRAWING NUMBER

REVISION

P.O. Box 580

208-454-1800 Fax 208-454-1801

JOB LOCATIONSCALE:

DRAWN BY

OF

Q2

1 1/4" EYEBOLT7/8" EYEBOLT3/4" EYEBOLT

1/2" EYEBOLT5/8" EYEBOLT

E.H.S. CABLE WITHE.H.S. CABLE WITHE.H.S. CABLE WITH

E.H.S. CABLE WITHE.H.S. CABLE WITH

5/8"1/2"3/8"

1/4"5/16"

DIAGONAL CABLE, EYEBOLT END

X-BRACE CABLE& BRACE GRIP

SLOT IN WEB TOINSERT HILLSIDEWASHER & EYEBOLT

FLATWASHER

COLUMN ORRAFTER WEB

HILLSIDEWASHER

NUT EYEBOLT

TEK SCREW

RIGIDFRAME

COLUMN

EAVESTRUT

I9EAVE STRUT TORIGID FRAME COLUMN

RA20

4"

2"

CL

STEELLINE

I9EAVE STRUT TORIGID FRAME COLUMN

RA20

4"

2"

CL

STEELLINE

11"

(4) BOLTS1/2" x 1 1/2" (TYP)

(6) BOLTS1/2" x 1" (TYP)

ROOFPURLINS

RF RAFTER

RAFTERFLANGEBRACE

G1ROOF PURLIN TO INTERIORRIGID FRAME RAFTER

(6) BOLTS1/2" x 1" (TYP)

H1 SIDEWALL GIRT TOINTERIOR FRAME COLUMN

FLANGEBRACE

(AS REQ'D.)

SIDEWALL GIRTS

RIGIDFRAME

COLUMN

TEK SCREW

EAVESTRUT

I8

ENDWALLRAFTER

EAVE STRUT TO ENDWALL RAFTER

Clearance

STEELLINE

RA20

4"

2"

CL

4"

TEK SCREW

I8EAVE STRUT TO ENDWALL RAFTER

Clearance1/4"

RA20

4"

2"

CL

4"

(4) BOLTS1/2" x 1 1/2" (TYP)

ENDWALLRAFTER

Q4DIAGONAL CABLE, EYEBOLT END

X-BRACE CABLE& BRACE GRIP

FLATWASHER X-ANGLE

HILLSIDEWASHER

NUT

EYEBOLT

Q5SP-3HXA & (2) SP-CA3 @ ENDWALLCOLUMN

SP-3HXA

X-BRACECABLE

& BRACEGRIP

(2) SP-CA3

ANCHOR BOLT

CONCRETE

ENDWALL COLUMN (DOUBLE 'C')

J2 EAVE STRUT TO RIGID FRAME@ INTERIOR BAYS

1/2"

RIGID FRAMECOLUMN

RIGID FRAMERAFTER

(4) BOLTS1/2" x 1 1/2" (TYP)

EAVESTRUT

F12

RAFTERSPLICE PLATES

ENDWALLRAFTER

SEE ENDWALL DRAWINGFOR BOLT DIA AND TYPE.

ENDWALL RAFTER SPLICEAT RIDGE

INSIDECLOSURE

BASECHANNEL(BC-)

T2SECTION THRU WALL PANELAND CONCRETE FOUNDATION

CONCRETE FOUNDATION BY OTHERS, MUST BEADEQUATE TO SAFELY RESIST THE LOADS IN

THE REACTION REPORT.

WALLPANEL

FOUNDATIONBASE TRIM

Page 9: BUILDING LOADS / DESCRIPTION...of structural steel building". allowable stress design latest edition. b.all cold formed members are designed in accordance with aisi "specifications

R & M STEEL COMPANY

Caldwell, Idaho 83606

DRAWING NUMBER

REVISION

P.O. Box 580

208-454-1800 Fax 208-454-1801

JOB LOCATIONSCALE:

DRAWN BY

OF

1. FIELD CUT X-BRACE THRU GIRTS (AS REQ'D).2. FIELD CUT X-BRACE TO LENGTH (AS REQ'D).3. FIELD FIT AND DRILL GIRTS AT CORNER

COLUMN (AS REQ'D).4. FIELD LOCATE WALK DOORS, WINDOWS,

AND LOUVERS (AS REQ'D).5. FIELD FIT WINDSTRUT (AS REQ'D).

9. LAP RAKE ANGLE 1", USE (2) 12-14 x 1" TEKS.8. LAP BRIDGE ANGLE 1", USE (2) 12-14 x 1" TEKS.

6. FIELD CUT 3'-4" ELEV. GIRT AND TEK TO8 1/4" WALK DOOR JAMB.

7. FIELD FIT FLANGE BRACES AS REQ'D.

Y1FIELD NOTESW2

WIND STRUT - HINGE BRACKET SUPPORT

RIGID FRAMERAFTER

RIGID FRAMERAFTER

(1) A325 BOLT 3/4" x 2"(2 PLACES)

WINDSTRUT - BACK TO BACK4" CEE ASSEMBLY

HINGE BRACKET/ STUB COLUMM

EW GIRTSBB PLATE

BB PLATE

(4) BOLTS 1/2" x 1" TYP

BOLTS 1/2" x 1" TYP

WINDSTRUT ASSEMBLY DETAIL

SECTION VIEW

BOLTS1/2" x 1"(TYP.)

BOLTS1/2" x 1"(TYP.)

BACK TO BACK4" CEE(BBPLATE)

WINDSTRUTCLIP

BACK TO BACK4" CEE

FIELDCUT & DRILL

AS REQ'D

(BBPLATE)WINDSTRUT

CLIP

8" ROOFPURLIN

ENDWALLRAFTER

ARC8ANTI-ROLL CLIP DETAIL

(4) BOLTS1/2" x 1" (TYP)

4-BOLT CLIP w/6" x 7" x .180"GUSSET

FORMAT IS BDDxWTHH

(6=6", 8=8", 0=10", 2=12")

(3=3/16", 4=1/4", 5=5/16" 6=3/8", 8=1/2",0=5/8", 2=3/4")

(14=.1495, 17=.1793, 25=.2500, 31=.3125)

WELDED MEMBER TYPE.MEMBER DEPTH IN INCHES.FLANGE WIDTH IN INCHES.

FLANGE THICKNESS IN 1/16" INCH UNITS.

WEB THICKNESS IN DECIMAL INCH UNITS.

===

=

=

BDDW

T

HH

Y2BUILT-UP NOTES

Page 10: BUILDING LOADS / DESCRIPTION...of structural steel building". allowable stress design latest edition. b.all cold formed members are designed in accordance with aisi "specifications

RA

20

RA

20

E-1 E-2 E-3

E-3E-2E-1

P-1(Typ) P-2(Typ) P-3(Typ)

P-1(Typ) P-2(Typ) P-3(Typ)

CB-3CB-3

CB-4

CB-4

CB-3 CB-3

EC-1

EC-2

EC

-3E

C-4

EC

-5E

C-5

*E

C-4

*E

C-3

*

EC-2*

EC-6

EC

-7E

C-8

EC

-8E

C-7

RF1-4 RF2-1 RF2-1

RF2-1RF2-1RF1-1

RF1-2

RF1-3

RF2-2

RF2-2

RF2-2

RF2-2

ER-1

ER-1*

G1

ARC8 RCAP

(20)

25'-5"

(20)

25'-5"

(20)

ROOFSHEETING

PANELS: 26 Ga. PBRSandstone Beige

F

A

RO

OF

SU

RF

AC

E 2

25'-0"

RO

OF

SU

RF

AC

E 3

25'-0"

1 4

2 320'-0" 20'-0" 20'-0"

11"

60'-0" OUT-TO-OUT OF STEEL

ROOF FRAMING PLAN

2'-8 1/4"

2'-8 1/4"

2'-8 1/4"

2'-8 1/4"PURLINLAP

MEMBER TABLEROOF PLANMARK PART LENGTHP-1 8x25Z13 22'-8 1/4"P-2 8x25Z15 25'-4 1/2"P-3 8x25Z13 22'-7 3/4"E-1 80x5E14 19'-11 3/4"E-2 80x5E14 19'-11 1/2"E-3 80x5E14 19'-11 1/2"

CB-3 1/4EHS 23'-0"CB-4 1/4EHS 28'-0"

R & M STEEL COMPANY

Caldwell, Idaho 83606

DRAWING NUMBER

REVISION

P.O. Box 580

208-454-1800 Fax 208-454-1801

JOB LOCATIONSCALE:

DRAWN BY

OF

AS PER RIGID FRAME CROSSINSTALL ROOF FLANGE BRACE

SECTION

Q2

Q2

4"

W.S.

W.S.

W.S.

W.S.

W.S.

W.S.

Page 11: BUILDING LOADS / DESCRIPTION...of structural steel building". allowable stress design latest edition. b.all cold formed members are designed in accordance with aisi "specifications

RF2-1 RF2-1RF1-4 EC-7

E-1 E-2 E-3

CB-2CB-2

BC-2

G-8

G-8

G-8

BC-2

G-9

G-9

G-9

BC-2

G-10

G-10

G-10

1

1

1

1'-4"

1'-4"

1'-4"

1'-4"GIRTLAPS

1 4

2 320'-0" 20'-0" 20'-0"

4"

11"

60'-0" OUT-TO-OUT OF STEEL

SIDEWALL FRAMING: GRID A

3'-4"

4'-0"

5'-8"

5'-0"

18'-0"

H1

T2

RF2-1 RF2-1EC-7 RF1-1

E-3 E-2 E-1

SF

30

70CB-2

CB-2

BC-2

G-10

G-10

G-10

BC-2

G-9

G-9

G-9

BC-2

G-8

G-8

G-8

1

1

1

1'-4"

1'-4"

1'-4"

1'-4"GIRTLAPS

4 1

3 220'-0" 20'-0" 20'-0"

4"

11"

60'-0" OUT-TO-OUT OF STEEL

SIDEWALL FRAMING: GRID F

3'-4"

4'-0"

5'-8"

5'-0"

18'-0"

15'-0" 3'-0" 2'-0"

H1

T2

MEMBER TABLEGRID A & FMARK PART LENGTHE-1 80x5E14 19'-11 3/4"E-2 80x5E14 19'-11 1/2"E-3 80x5E14 19'-11 1/2"G-8 8x25Z16 21'-4"G-9 8x25Z16 22'-8"G-10 8x25Z16 21'-4"

BC-2 8x25C16 20'-0"CB-2 5/16EHS 25'-0"

CONNECTION PLATESGRID A & F

ID MARK/PART1 SWC-N

R & M STEEL COMPANY

Caldwell, Idaho 83606

DRAWING NUMBER

REVISION

P.O. Box 580

208-454-1800 Fax 208-454-1801

JOB LOCATIONSCALE:

DRAWN BY

OF

AS PER RIGID FRAME CROSS SECTION

INSTALL SIDEWALL FLANGE BRACE

Q2

Q2

I9I8 J2

I8

Q2

J2I9

Q2

Page 12: BUILDING LOADS / DESCRIPTION...of structural steel building". allowable stress design latest edition. b.all cold formed members are designed in accordance with aisi "specifications

EC-1 EC-2 EC-3 EC-4 EC-5 EC-5* EC-4* EC-3* EC-2* EC-6

BB

-1

BB

-2

BB

-3

BB

-3

BB

-2

BB

-1

RA20 RA20

BC-1

G-1

G-1

G-1

G-2

G-3 G-4 G-4 G-4 G-4 G-4G-3

G-2

BC-1

G-1

G-1

G-1

1

1

1

1

1

1

1

1

1

1

1

1

2'-3"

1'-2"

6'-7" 6'-0" 6'-0" 6'-0" 6'-0" 6'-0" 6'-7"

1'-2"

2'-3"

F A

E B

50'-0" OUT-TO-OUT OF STEEL

ENDWALL FRAMING: GRID 1

1.00012 1.000

12

3'-4"

4'-0"

5'-8"

4'-0"

1'-0"

18'-0"

45'-0"

(CLEAR WIDTH)

17'-0"

16'-6"

14'-0"

(C.L

. O

F G

IRT)

(C.L

. O

F H

ING

E)

(CLE

AR

HE

IGH

T)

A9

B35

D16

D16

EC-7 EC-8 EC-8 EC-7

ER-1 ER-1*

RA20 RA20

CB-1

CB-1

2 2

BC-3

G-5

G-5

G-5

BC-4

G-6

G-6

G-7

BC-3

G-5

G-5

G-5

BRDG ANGLE

FB1D FB1D

3 3 3 3 3 3 3 3

4

4

4

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

4

4

4

6

6

6

6

6

6

14'-4" 20'-0" 14'-4"8" 8"

A F

C D

50'-0" OUT-TO-OUT OF STEEL

ENDWALL FRAMING: GRID 4

1.00012

1.00012

3'-4"

4'-0"

5'-8"

5'-0"

18'-0"

A3 ARC8 ARC8 B4

C2

D1D1

E1 E2

F12

Q5

Q4

T2

MEMBER TABLEGRID 1 & 4MARK PART LENGTHBB-1 D4x5C16 18'-0 1/16"BB-2 D4x5C16 18'-0 9/16"BB-3 D4x5C16 18'-1 1/4"EC-1 W6x20 17'-6 1/8"EC-2 W8x10 1'-11 3/4"EC-3 W8x10 1'-11"EC-4 W8x10 2'-5"EC-5 W8x10 2'-11"EC-6 W6x20 17'-6 1/8"EC-7 8x25C15 16'-8 3/4"EC-8 D8x5C14 17'-11 1/16"ER-1 W8x10 25'-1 1/16"ER-1* W8x10 25'-1 1/16"G-1 8x25Z16 1'-11"G-2 8x25Z16 0'-6"G-3 8x25Z16 5'-11"G-4 8x25Z16 5'-4"G-5 8x25Z16 13'-8"G-6 8x25Z16 19'-4"G-7 8x25Z14 19'-4"

BC-1 8x25C16 1'-11"BC-3 8x25C16 13'-8"BC-4 8x25C16 19'-4"CB-1 1/4EHS 25'-0"

BOLT TABLEGRID 1 & 4LOCATION QUAN TYPE DIA LENGTHER-1/ER-1* 8 A325 5/8" 1 3/4"EC-1/FRAME 2 A325 3/4" 2"EC-2/FRAME 4 GR_5 1/2" 1"EC-3/FRAME 4 GR_5 1/2" 1"EC-4/FRAME 4 GR_5 1/2" 1"EC-5/FRAME 4 GR_5 1/2" 1"EC-6/FRAME 2 A325 3/4" 2"Cor_Column/Raf 4 GR_5 1/2" 1"EC-8/ER-1 4 GR_5 1/2" 1"EC-8/ER-1* 4 GR_5 1/2" 1"Back Braces 2 A325 3/4" 2"

CONNECTION PLATESGRID 1 & 4

ID MARK/PART1 BBPLATE2 SP-3HXA3 SP-CA34 SWC-N5 CA526 SA

FLANGE BRACE TABLEGRID 1 & 4ID MARK LENGTH1 FB1D 1'-4 3/4"

R & M STEEL COMPANY

Caldwell, Idaho 83606

DRAWING NUMBER

REVISION

P.O. Box 580

208-454-1800 Fax 208-454-1801

JOB LOCATIONSCALE:

DRAWN BY

OF

INSTALL ENDWALL FLANGE BRACE

T2

B7

B2

C6

C7 BIFOLD DOOR NOTE:

TO APPROXIMATE CENTER OFJAMB COLUMN (1/2" LESS).

1.) ADJUST BIFOLD DOOR JAMB WHEEL

2.) FIELD DRILL & BOLT HINGE TO HB

3.) FIELD WELD HINGE TO HB

W.S

.

BE

HIN

D

W.S

.

BE

HIN

D

W.S

.

BE

HIN

D

W.S

.

BE

HIN

D

W.S

.

BE

HIN

D

W.S

.

BE

HIN

D

W2

Page 13: BUILDING LOADS / DESCRIPTION...of structural steel building". allowable stress design latest edition. b.all cold formed members are designed in accordance with aisi "specifications

ENDWALL INSULATION: GRID 1INSULATION: 4.00" Thick VR

1"12

1"12

F AE B

SIDEWALL INSULATION: GRID AINSULATION: 4.00" Thick VR

1 42 3

18'-6

" (7

2)

18'-6

" ( 7

2)

18'-6

" (7

2)

18'-6

" ( 7

2)

18'-6

" (7

2)

18'-6

" ( 7

2)

18'-6

" ( 7

2)

18'-6

" ( 7

2)

18'-6

" ( 7

2)

18'-6

" ( 7

2)

ENDWALL INSULATION: GRID 4INSULATION: 4.00" Thick VR

1"12

1"12

A FC D

19'-0

" (4

8)

19'-0

" (4

8)

19'-6

" ( 7

2)

19'-6

" (7

2)

20'-0

" (7

2)

20'-0

" (7

2)

20'-6

" ( 7

2)

20'-6

" (7

2)

21'-0

" (7

2)

21'-0

" (7

2)

20'-6

" (7

2)

20'-6

" (7

2)

20'-0

" ( 7

2)

20'-0

" (7

2)

19'-6

" ( 7

2)

19'-6

" (7

2)

19'-0

" (4

8)

19'-0

" (4

8)

SIDEWALL INSULATION: GRID FINSULATION: 4.00" Thick VR

4 13 2

18'-6

" (7

2)

18'-6

" ( 7

2)

18'-6

" (7

2)

18'-6

" ( 7

2)

18'-6

" (7

2)

18'-6

" ( 7

2)

18'-6

" ( 7

2)

18'-6

" ( 7

2)

18'-6

" ( 7

2)

18'-6

" ( 7

2)

R & M STEEL COMPANY

Caldwell, Idaho 83606

DRAWING NUMBER

REVISION

P.O. Box 580

208-454-1800 Fax 208-454-1801

JOB LOCATIONSCALE:

DRAWN BY

OF

INSULATION TABLEROOF PLAN = R19 - 6"

ROLL QUAN MARK WIDTH LENGTH

1 10 ROOF 6'-0" 51'-6"

@ SIDE LAP

INSULATION DETAIL

STAPLE @ 4" O.C.

(AS SHOWN)

VINYL FACING

FOLD

PANEL

INSULATION

ROOF PURLIN OR WALL GIRT

VINYL FACING

@ EAVE

INSULATION DETAIL

EAVE STRUT

DOUBLE STICK TAPE

ROOF SHEET

FOLD WHITE VINYL FACING

INSULATION

OVER TOP OF INSUL.

BUTYLCLOSUREBUTYL

VINYL FACING

INSULATION DETAIL

INSULATION

OVER INSULATION

BT1

FOLD VINYL FACING

ANGLEBASE CLOSURE

INSIDEDOUBLE STICK TAPE

Page 14: BUILDING LOADS / DESCRIPTION...of structural steel building". allowable stress design latest edition. b.all cold formed members are designed in accordance with aisi "specifications

TYPICAL TEK SPACING FOR HIGH RIB PANELSNOTE: ALIGN ROOF PANEL HI-RIBS WITH WALL PANEL HI-RIBS.

II. TYPICAL SPACING AT PANEL ENDS

2) TYPICAL SPACING AT RIDGE CAP.3) TYPICAL SPACING AT BASE ANGLE.4) TYPICAL SPACING AT RAKE ANGLE.5) TYPICAL SPACING AT PANEL LAP.

1) TYPICAL SPACING AT EAVE STRUT.

2-3/4"

1"

DO NOT CUT HORIZONTAL EDGE(NEED EDGE TO POP RIVET TO RAKE)

EAVE FASCIA (S-17 or S-23)

CUT ON DOTTED LINE

POP RIVET RAKE &EAVE TOGETHER HERE

RAKE FACIA

MITER DETAIL: EAVE-TO-RAKE

NOTE ROOF PANELO.H. @ EAVE

SEE DETAIL 1ROOF PANEL

INSIDE CLOSURE

WALL Z-GIRT

WALL PANEL

PANEL NOTCH

CONCRETEFOUNDATION

BASE CHANNEL(ANCHORED TO FLOOR)INSIDE CLOSURE

WALL PANEL

TEK & STITCH SCREWS(SEE PANEL FASTENER DETAIL)

BASE TRIMBASE TRIM

BASE DETAIL

BASE TRIM

BASE CHANNEL

#14 x 7/8 STITCH TEK @ 12" O.C.

RAKE FASCIA(S-188)

#14 x 7/8 STITCH TEK @ 12" O.C.

OUTSIDE CLOSURE

WALL PANEL

ROOF PANEL

PURLIN

FLANGE BRACE(IF APPLICABLE)

RIGID FRAMERAFTER

RAKE TRIM DETAIL

Stitch TEK2'-0" O.C.

(TYP.)

2'-0" O.C. (TYP.)

R & M STEEL COMPANY

Caldwell, Idaho 83606

DRAWING NUMBER

REVISION

P.O. Box 580

208-454-1800 Fax 208-454-1801

JOB LOCATIONSCALE:

I. TYPICAL SPACING AT INTERMEDIATE PURLINS & GIRTS.

DRAWN BY

OF

#14 x 7/8 STITCH TEK

#14 x 7/8 STITCH TEK

(STRUCTURAL) #12 TEK

(STRUCTURAL) #12 TEK

12" O.C. (TYP.)

S-17 EAVE TRIM DETAIL & WALL STITCH TEK LAYOUT

2'-0" O.C.TYPICAL SIDE LAP STITCH TEK SPACING 2'-0" 0.C. (TYP)

III. TYPICAL STITCH TEK SPACING (SIDE LAP ONLY)

R & M STEEL CO.

PEAK BOX

S-188 RAKE TRIMS-188 RAKE TRIM

1) MITER S-188 RAKE TRIM @ PEAK & SEAL.

2) INSTALL PEAKBOX & SEAL.

NOTE:

3) MITER S-188 AND S-17 @ CORNERS & SEAL.

CALDWELL, ID.

PEAK BOX DETAIL

ROOF PANEL MASTIC DETAIL@ ROOF PANELS ONLY

ROOF PANEL

(1) ROWBUTYL(1) ROW

BUTYL

STITCH TEK@ 2'-0" O.C.

STITCH TEK@ 2'-0" O.C.

BUTYL (MASTIC)

8"

4" (MIN.)

OUTSIDE CLOSURE

S-17 (EAVE TRIM)

#14 x 7/8 STITCH TEK @ 12" O.C.

OU

TO

UT

NOTE: FIELD PAINT EXPOSED BI-FOLDDOOR STRUCTURAL STEEL (BY OTHERS).

END VIEWBI-FOLD DOOR TRIM LAYOUT

USE TEK 5 @STRUCTURALMEMBERS

S-58

BI-FOLD 'Z'

BI-FOLD 'L'

WALLGIRT

WALL PANEL

BOTTOMRUBBER

TOPRUBBER

HEADER TRIM

FINISHFLOOR

3"

INSIDE CLOSURE

ROOF PANEL ROOF PANEL

(2) ROWS BUTYL@ LAP

(2) ROWS BUTYL@ LAP

DIE FORMED RIDGE

DIE FORMED RIDGE CAP DETAIL

FOLD VINYL FACINGOVER INSULATION

INSULATION

DOUBLE STICKTAPE

DOUBLESTICKTAPE

EAVESTRUT

BUTYL

INSIDECLOSURE

BUTYL

FOLD WHITE VINYL FACINGOVER TOP OF INSUL.

INSULATION

ROOF PANEL

DETAIL 1

Page 15: BUILDING LOADS / DESCRIPTION...of structural steel building". allowable stress design latest edition. b.all cold formed members are designed in accordance with aisi "specifications

CAULKING (BY OTHERS)

TRIM BEHIND PANEL AS REQ.NOTE: FIELD NOTCH PANEL AND SLIDE HEADER

HEADER TRIM DETAIL

3"3"HEADERTRIM

JAMB TRIMSTIFFENER

F.F.

JAMB TRIM

FRAMED OPENING DETAIL FOROVERHEAD DOOR OR WALK DOOR

R & M STEEL COMPANY

Caldwell, Idaho 83606

DRAWING NUMBER

REVISION

P.O. Box 580

208-454-1800 Fax 208-454-1801

JOB LOCATIONSCALE:

DRAWN BY

OF

JAMB TRIM POP RIVET @

2'-0" O.C.

JAMB TRIM STIFFENER

STRUCT. TEK@ 2'-0" O.C.

EXTERIORWALL PANEL

JAMB

JAMB TRIM DETAIL

TRIM DETAIL @ JAMB COLUMNFOR BI-FOLD DOOR OPENING

POP RIVET @2'-0" O.C.

OUT

JAMB TRIM

WALL PANEL

JAMB TRIMSTIFFENER

JAMBCOLUMN

STRUCT. TEK@ 2'-0" O.C.

HEADER TRIM

INSIDE CLOSURE

HEADER

EXTERIORWALL PANEL

Page 16: BUILDING LOADS / DESCRIPTION...of structural steel building". allowable stress design latest edition. b.all cold formed members are designed in accordance with aisi "specifications

18'-1"

18'-1"

18'-1"

18'-1"

18'-1"

18'-1"

18'-1"

18'-1"

18'-1"

18'-1"

18'-1"

18'-1"

18'-1"

18'-1"

18'-1"

18'-1"

18'-1"

18'-1"

18'-1"

18'-1"

S-1

1

S-1

1

S-17

1 42 3

SIDEWALL SHEETING: GRID APANELS: 26 Ga. PBR - Sandstone Beige

18'-1"

18'-1"

18'-1"

18'-1"

18'-1"

18'-1"

18'-1"

18'-1"

18'-1"

18'-1"

18'-1"

18'-1"

18'-1"

18'-1"

18'-1"

18'-1"

18'-1"

18'-1"

18'-1"

18'-1"

S-1

1

S-1

1

S-17

1

2

1

2

3

4 13 2

SIDEWALL SHEETING: GRID FPANELS: 26 Ga. PBR - Sandstone Beige

TRIM TABLEFRAME LINE A & F

ID MARK LENGTH

S-17 31'-6"S-11 18'-0"

4 BT1 31'-6" 1 JMBTRM 7'-4" 2 JMBSTF 7'-4" 3 HEDTRM 4'-0"

R & M STEEL COMPANY

Caldwell, Idaho 83606

DRAWING NUMBER

REVISION

P.O. Box 580

208-454-1800 Fax 208-454-1801

JOB LOCATIONSCALE:

DRAWN BY

OF

4

4

Page 17: BUILDING LOADS / DESCRIPTION...of structural steel building". allowable stress design latest edition. b.all cold formed members are designed in accordance with aisi "specifications

18'-1"

18'-2"

1'-4"

1'-7"

1'-10

"

2'-1"

2'-4"

2'-7"

2'-10

"

2'-10

"

2'-7"

2'-4"

2'-1"

1'-10

"

1'-7"

1'-4"

18'-2"

18'-1"

7'-10

3/4

"(1

6)

8'-2 3

/4"

(16

)

PANELS: 26 Ga. PBRSandstone Beige

S-1

1

S-1

1

S-188 S-188PK BOX

1.00012

1.00012

F AE B

ENDWALL SHEETING: GRID 1PANELS: 26 Ga. PBR - Sandstone Beige

18'-1"

18'-2"

18'-5"

18'-8"

18'-11

"

19'-2"

19'-5"

19'-8"

19'-11

"

19'-11

"

19'-8"

19'-5"

19'-2"

18'-11

"

18'-8"

18'-5"

18'-2"

18'-1"

S-1

1

S-1

1

S-188 S-188PK BOX

1.00012

1.00012

A FC D

ENDWALL SHEETING: GRID 4PANELS: 26 Ga. PBR - Sandstone Beige

TRIM TABLEFRAME LINE 1 & 4

ID MARK LENGTH

PK BOX 2'-6"S-188 26'-6"

1 HEDTRM 24'-0" 2 S-58 8'-6" 3 JMBSTF 17'-6" 4 JMBTRM 17'-6" 5 BI-FOLD 'Z' 24'-0" 6 S-58 24'-0" 7 BI-FOLD 'L' 24'-0"

S-11 18'-0" 8 BT1 4'-6" 9 BT1 26'-6"

R & M STEEL COMPANY

Caldwell, Idaho 83606

DRAWING NUMBER

REVISION

P.O. Box 580

208-454-1800 Fax 208-454-1801

JOB LOCATIONSCALE:

DRAWN BY

OF

5

7

2 2

22

6

1

33

44

9

8 8